Win Progress Co., Ltd.

TECHNICAL SERVICE BULLETIN


Manufacturer Product Line Engine Model Page
VOLVO EXCAVATOR - 1 of 2
Component Group Model Series Date
ELECTRICAL EC 290 B - 1/2/2013
Subject
-187 SID 251 FMI 1(System Battery Low Voltage)
Failure/Problem

-Battery Internal Leakage

Symptom

-DTC code appears on MDC and central warning alarm after first start cranking. Engine can’t crank.

History

Storage long time/Not have daily machine warm up plan.

Cause & analysis


-Battery internal leakage because of long time storage.(can recharge again
-Battery internal plate damage.
-Battery terminal loosen.
-Big resistance wire line.
-Battery relay cannot give good contact point for system load usage.
-Starter motor damage.
-Pull/Hold solenoid abnormal(not have good contact for motor load).

Action
187 SID 251 FMI 1
According to error code saying, we check the batter voltage is OK but can’t stand cranking load. So we
connect with another battery to get good strength ampere for cranking load. After finish the battery joining,
we crank the machine again to start engine operation at idle speed.
Never boost-start the machine by connecting directly to the starter motor. This may result in uncontrolled
machine movements. When using another machine to boost-start, it must not touch the machine that is being
started.
If a tool touches a cable connected between the positive terminal and the chassis, there is danger that it will cause
sparks. Battery post clamps must be tightly connected. If loosely connected, the terminal may burn or be eroded by
sparks caused by defective contact. Battery acid can burn or blind you. If acid gets on your skin or in your eyes,
immediately wash with plenty of clean water and consult a doctor immediately.

Connecting Start Cables Removing Start Cables

Disclaimer:
This Technical Service Bulletin cannot guarantee the accuracy of all information.
Please confirm the information with an appropriate manual.
Win Progress Co., Ltd.
TECHNICAL SERVICE BULLETIN
Manufacturer Product Line Engine Model Page
VOLVO EXCAVATOR - 2 of 2
Component Group Model Series Date
ELECTRICAL EC 290 B - 1/2/2013

The specific gravity level of the acid should be within the shaded area.
SOC (State Of Charge).

TERMINAL SIZE

Remark
!! Always remove watches, rings, bracelets and other metallic objects from the body before starting to work on the
electrical system.
!! When working on the electrical system, the following instructions as well as instructions in respective section
must be followed carefully.
!! Also read instructions in Section Safety and in the Operator's Manual.

Prepared by: Hlaing Myo Aung Title: Mechanic


Acknowledged by: Mr.Zulkifli Title: Dept; Head
Company: Reman