14.4-Mbps in 3g Network Guideline

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 23

Network Planning Cell I{J ~~f.

ftTij ~
GM (NWP-CM), Punjab Telecom Circle
Room No. 201, BSNL Telephone Exchange, ~l BHARAT
S~;;~;~
(A GoYt. of India Entarpnsa)
LIMITED
Sector -49/C, Chandigarh -160047.

All SSAHeads,
Punjab Telecom Circle.

I
No: c. n r.s N l-J p- ~ ~q l 1'~'4
tlb 1'5 I~dated: '/.3
oS· 0,2.' I.
Sub: Implementation of 14.4 Mbps speed in the 3g Network in Punjab Telecom
Circle.

Please find enclosed herewith letter no S7-49/2004-CMTS/(pt.) dated


22.12.2010 and letter of even no dated 28.12.2010 regarding Implementation of
14.4 Mbps speed in the 3g Network in Punjab Telecom Circle by shifting the 3G
network on the IP media. The letter dated 28.12.2010 is self explanatory. As per
the para 9 of the letter Circles are required to go in details of media availability
at Node B and identify the options as detailed in the enclosed letter for
migrating it on the IP media. The entire work of migration is to be completed by
31.3.2011 progressively. The various options are again reproduced as follows: .
Type 1 : NodeB --- Tier2 - RNC
Type2 : NodeB --- FTTH-Tier2 - RNC
Type3 : NodeB --- CPE8 - Tier2 - RNC
Type4 : NodeB --- CPE8 - FTTH- Tier2 - RNC
TypeS: NodeB --- 3 E1 - Chanalized STM- RNC
Type6: Node B ---FEto 8E1/16E 1 Convertors/WDM Splitter
You are requested to kindly examine the available media and send
the node wise report in the enclosed proforma immediately as the same is to be
forwarded to BSNLHQ on every Tuesday. Before forwarding,the details should be
personally checked by the DGM Concerned and approved by SSAHead.
The details should be sent immediately to this office on email id
dksharda 12@gmail.com and sanjaYiindalits@gmail.com.

The details will be discussed in the next management meeting to be held


on 9th Feb 2010.

0~>~~tl
DET(NWP-CM)
Chandigarh.
Copy to:
1. GM(CFA) % CGMT Punjab for kind information please.
2. SDE(Plg-l) for uploading the details on Punjab Intranet

Corporate office: Sharat Sanchar Shawan, Harish Chander Mathur Lane Janpath , New Delhi-11 0001
letter wef 11th Jan 2010
Present Node-b connectivity
Present 3G network of the Jaipur is designed with 310 Node-
B and Type 3 RNC. The Hub - Sub Hub – NodeB
architecture is being adopted. At each Node-B 3E1 are
considered for the design. Out of the these 310 Node-B
279 Node-Bs are integrated in the network. So there are
HUB – 12 . Fiber is available at these location.
SUB HUB – 50. Fiber is available at these location.
Node B – 248.
Out of this Node B Connectivity there are 65 NodeB are on
M/W and 2 NodeB are on HDSL.
Proposed Node B Connectivity

Node-B

Node-B

Channelised BSNL Tx Equip


STM Node-B Node-B Node-B

RNC
1+1
GE
BSNL IP Network of NIB
RNC will be connected to NIB network via
1+1 optical GE Port. A single aggregated
connectivity for all the nodes will be
provided. The complete aggregation of the
all the Node B will be done in NIB network.
All the Node-B will be connected to NIB
network in star topology.
Node-B which will not be connected in IP
network. Will be connected via Chanalized
STM.
Type of Connectivity
New connectivity is divided into five types
Type1 : NodeB --- Tier2 – RNC
Type2 : NodeB --- FTTH– Tier2 – RNC
Type3 : NodeB --- CPE8 – Tier2 – RNC
Type4 : NodeB --- CPE8 – FTTH – Tier2 –
RNC
Type5 : NodeB --- 3 E1 – Chanalized STM –
RNC
Type 6: Node B---FE to 8E1/16 E1
convertors/WDM splitter
Type 1 Connectivity
In this connectivity Node B will be directly
connected to tier2 network of the NIB which
in turn will be connected to RNC. FE Port
(electrical)

Node B

Optical
Tier2 Optical Port
Port
RTXM 191DD5-B
WHTD 453001 Node B with this
1.25G-40KM-1550nm
SM-ESFP
configuration will be
require 1550nm SFP
Type 2 Connectivity
For this type the connectivity will made using FTTH
and tier2 of the NIB
For the southbound connectivity FTTH uses DWDM on
single fiber. So ONT will be required which will
provide four FE ports. ONT and its installation is to
be arranged by BSNL. No other equipment will be
FE Port
connected toFTTH
this ONT to provide full bandwidth to
(electrical)
NodeB.
Node B
ONT
Single Fiber
100Mbps

Tier2 DWDM port Optical


Single fiber Port
Optical Port operates on Single fiber to 4
RTXM 191DD5-B UL 1310 nm FE Electrical
WHTD 453001 Ports
DL 1490 nm
1.25G-40KM-1550nm
SM-ESFP
Type 3 Connectivity

Type3 connectivity is defined as NodeB --- CPE8 –


Tier2
At present CPE8 are having the SFP with 1310nm
while SFP at tier2 are having 1550nm. So it is
required to change the SFP in CPE8. FE Port
(electrical)
FE Port
(electrical)

TX equip TX equip
CPE8 CPE8
Node B

Tier2

Optical Port
Optical Port
RTXM 139-400
RTXM 191DD5-B Optical
WHTD 003001
WHTD 453001 Port
155M-15KM-1310nm
1.25G-40KM-1550nm
SM-ESFP
SM-ESFP
Type 4 Connectivity
Type4 connectivity is defined as NodeB --- CPE8 – FTTH –
Tier2 – RNC
For the southbound connectivity FTTH uses DWDM on single
fiber. So ONT will be required which will provide four FE
ports. ONT and its installation is to be arranged by BSNL. No
other equipment will be connected to this ONT to provide full
bandwidth to NodeB. FE Port
FE Port
(electrical)
FTTH (electrical)

TX equip TX equip
CPE8 CPE8
Node B
ONT
Single Fiber
100Mbps
Tier2
DWDM port
Single fiber Optical Port
Optical Port operates on Single fiber to 4
RTXM 139-400
RTXM 191DD5-B UL 1310 nm FE Electrical Optical
WHTD 003001
WHTD 453001 DL 1490 nm
Ports Port
155M-15KM-1310nm
1.25G-40KM-1550nm
SM-ESFP
SM-ESFP
Type 5 Connectivity
This connectivity will be used for remaining
NodeBs i.e. NodeB on M/W (65) and HDSL
(2). 67 NodeBs falls under this category.
These Node B will be connected via
chanalised STM. One Chanalized card
support one STM so it will be required to
procure 5 chanalized card by BSNL.
Three E1 from 15 NodeB will be
multiplexed in to one chanalized STM by the
BSNL. This STM will be connected to RNC.
Type 6 Connectivity

FE to 8E1 convertors for the sites without IP


connectivity as of now can be deployed This
will ensure an all IP 3G network to the
extent possible
There can be the possibility of using a WDM
splitter to extend Node B IP interface to
Nearest Tier 2 location at some of the sites
The E1 ports spare in RNC can be utilised to
increase the no of E1s where IP connectivity
is not possible under any of the methods
RNC Connectivity

RNC will be connected to NIB at tier2 with


1+1GE port.
Optical GE port will be used for the same.
Wavelength for the same will be 1550nm.
RNC

Tier2 Optical Port


RTXM 191DD5-B RNC with optical GE
WHTD 453001
1.25G-40KM-1550nm port - 1550nm SFP
SM-ESFP

You might also like