Professional Documents
Culture Documents
14.4-Mbps in 3g Network Guideline
14.4-Mbps in 3g Network Guideline
14.4-Mbps in 3g Network Guideline
ftTij ~
GM (NWP-CM), Punjab Telecom Circle
Room No. 201, BSNL Telephone Exchange, ~l BHARAT
S~;;~;~
(A GoYt. of India Entarpnsa)
LIMITED
Sector -49/C, Chandigarh -160047.
All SSAHeads,
Punjab Telecom Circle.
I
No: c. n r.s N l-J p- ~ ~q l 1'~'4
tlb 1'5 I~dated: '/.3
oS· 0,2.' I.
Sub: Implementation of 14.4 Mbps speed in the 3g Network in Punjab Telecom
Circle.
0~>~~tl
DET(NWP-CM)
Chandigarh.
Copy to:
1. GM(CFA) % CGMT Punjab for kind information please.
2. SDE(Plg-l) for uploading the details on Punjab Intranet
Corporate office: Sharat Sanchar Shawan, Harish Chander Mathur Lane Janpath , New Delhi-11 0001
letter wef 11th Jan 2010
Present Node-b connectivity
Present 3G network of the Jaipur is designed with 310 Node-
B and Type 3 RNC. The Hub - Sub Hub – NodeB
architecture is being adopted. At each Node-B 3E1 are
considered for the design. Out of the these 310 Node-B
279 Node-Bs are integrated in the network. So there are
HUB – 12 . Fiber is available at these location.
SUB HUB – 50. Fiber is available at these location.
Node B – 248.
Out of this Node B Connectivity there are 65 NodeB are on
M/W and 2 NodeB are on HDSL.
Proposed Node B Connectivity
Node-B
Node-B
RNC
1+1
GE
BSNL IP Network of NIB
RNC will be connected to NIB network via
1+1 optical GE Port. A single aggregated
connectivity for all the nodes will be
provided. The complete aggregation of the
all the Node B will be done in NIB network.
All the Node-B will be connected to NIB
network in star topology.
Node-B which will not be connected in IP
network. Will be connected via Chanalized
STM.
Type of Connectivity
New connectivity is divided into five types
Type1 : NodeB --- Tier2 – RNC
Type2 : NodeB --- FTTH– Tier2 – RNC
Type3 : NodeB --- CPE8 – Tier2 – RNC
Type4 : NodeB --- CPE8 – FTTH – Tier2 –
RNC
Type5 : NodeB --- 3 E1 – Chanalized STM –
RNC
Type 6: Node B---FE to 8E1/16 E1
convertors/WDM splitter
Type 1 Connectivity
In this connectivity Node B will be directly
connected to tier2 network of the NIB which
in turn will be connected to RNC. FE Port
(electrical)
Node B
Optical
Tier2 Optical Port
Port
RTXM 191DD5-B
WHTD 453001 Node B with this
1.25G-40KM-1550nm
SM-ESFP
configuration will be
require 1550nm SFP
Type 2 Connectivity
For this type the connectivity will made using FTTH
and tier2 of the NIB
For the southbound connectivity FTTH uses DWDM on
single fiber. So ONT will be required which will
provide four FE ports. ONT and its installation is to
be arranged by BSNL. No other equipment will be
FE Port
connected toFTTH
this ONT to provide full bandwidth to
(electrical)
NodeB.
Node B
ONT
Single Fiber
100Mbps
TX equip TX equip
CPE8 CPE8
Node B
Tier2
Optical Port
Optical Port
RTXM 139-400
RTXM 191DD5-B Optical
WHTD 003001
WHTD 453001 Port
155M-15KM-1310nm
1.25G-40KM-1550nm
SM-ESFP
SM-ESFP
Type 4 Connectivity
Type4 connectivity is defined as NodeB --- CPE8 – FTTH –
Tier2 – RNC
For the southbound connectivity FTTH uses DWDM on single
fiber. So ONT will be required which will provide four FE
ports. ONT and its installation is to be arranged by BSNL. No
other equipment will be connected to this ONT to provide full
bandwidth to NodeB. FE Port
FE Port
(electrical)
FTTH (electrical)
TX equip TX equip
CPE8 CPE8
Node B
ONT
Single Fiber
100Mbps
Tier2
DWDM port
Single fiber Optical Port
Optical Port operates on Single fiber to 4
RTXM 139-400
RTXM 191DD5-B UL 1310 nm FE Electrical Optical
WHTD 003001
WHTD 453001 DL 1490 nm
Ports Port
155M-15KM-1310nm
1.25G-40KM-1550nm
SM-ESFP
SM-ESFP
Type 5 Connectivity
This connectivity will be used for remaining
NodeBs i.e. NodeB on M/W (65) and HDSL
(2). 67 NodeBs falls under this category.
These Node B will be connected via
chanalised STM. One Chanalized card
support one STM so it will be required to
procure 5 chanalized card by BSNL.
Three E1 from 15 NodeB will be
multiplexed in to one chanalized STM by the
BSNL. This STM will be connected to RNC.
Type 6 Connectivity