Professional Documents
Culture Documents
Yb-20003 - ST-05 - 29.june.2020
Yb-20003 - ST-05 - 29.june.2020
NOTES:-
1) All dimensions are in feet & inches,
unless otherwise mentioned on drawing.
2) Contractor has to check and verify all dimensions
F
and levels, before execution of work. F
LEAVE DOWEL A B C D E 3) Figured dimensions shall be followed.
RODS OF Y10@5" 4) The reinforcement shall be of high yield
FOR STAIRCASE 31'-3" strength deformed bars of grade Fe500
8'-9" 2' 8'-9" 11'-9" conforming to IS:1786-1985
5) Concrete shall be of grade M20 conforming to
IS 456-2000
LINTEL BEAM TO DETAIL
6) Minimum lap length shall be 50xdia.
2Y10 Y8@8"c/c
4 4 7) Cover for
Y8@5"c/c (a) Footing : 50mm
(b) Column : 40 mm
6"
3"
(c) Plinth beam : 30 mm
(d) Roof beam : 25 mm
10'-9"
2Y10
E (e) Roof slab : 20 mm E
9" 9"
S1 S1 3'
3 S2 3
27'-6"
TYPICAL SECTION OF LOFT / LINTEL
6'
2 2 CUM SUNSHADE DETAILS
S2
S2
10'-9"
D S1 D
b/3
b/3
b/3
b/5
b/5
b/5
1 1 ℄
a/5
a/5
a/5
a/3
a/3
a/3
A/10 A/5 B/3 B/5 C/3 C/10
a
A B C D E A/10 A/3 B/5 B/3 C/5 C/10
a/10
a/10
a/10
a/10
a/10
a/10
℄
C C
A B C
℄
PLAN ℄
℄ ℄
LINTEL BEAM
A
PYRAMID Structural Consultant TITLE CHECKED BY : Y.B A
No. 2/145, Salem main road, Amman Nagar, PROJECT CONSULTANT
Puduchadram,Namakkal - 637 018, PALATIAL CONSTRUCTION TERRACE FLOOR SLAB LAYOUT & DETAILS
NAMAKKAL DESIGNED BY : M.R
Tamilnadu, India. PROJECT NO : YB-20003 DRWG NO : ST-05
email: pyramidstrconsultant@gmail.com REVISION
Ph: +91 9597691155 DATE : 29.JUN.2020 SCALE : 1:100 (A3) REVISED BY REVISION DETAILS DRAWN BY : B.D
NO.
1 2 3 4 5 6 7 8 9 10