NOTES:-
1) All dimensions are in feet & inches,
unless otherwise mentioned on drawing.
FGL 2) Contractor has to check and verify all dimensions
COLUMN
F
and levels, before execution of work. F
3) Figured dimensions shall be followed.
VARIES
6"
NGL 4) The reinforcement shall be of high yield
PLINTH BEAM strength deformed bars of grade Fe500
conforming to IS:1786-1985
RINGS 5) Concrete shall be of grade M20 conforming to
COLUMN VERTICAL IS 456-2000
A B C D E REINFORCEMENT 6) Minimum lap length shall be 50xdia.
MIN 3Nos (OR) LONGER SPAN STEEL 7) Cover for
31'-3" (a) Footing : 50mm
8'-9" 2' 8'-9" 11'-9" USE 8@12" C/C SHORTER SPAN STEEL
(b) Column : 40 mm
DEPTH
PCC 1:4:8 (c) Plinth beam: 30 mm
D
2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 2'-3"
4"THK (d) Roof beam : 25 mm
2'-412" 2'-12"
2'-412" 2'-12"
2'-412" 2'-12"
2'-412" 2'-12"
1
1
E FOOTING SIZE (e) Roof slab : 20 mm E
3"
4 4 3" 8) This building is designed for Ground floor.
F1 F1 F1 F1
SECTION A-A
10'-9"
SHORTER DIRECTION
2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 2'-3" LONGER SPAN
STEEL
2'-112" 2'-42"
2'-112" 2'-41"
2'-112" 2'-412"
2
1
3 3
F1 F1 F1
LONGER DIRECTION
27'-6"
6'
Column
2'-3" 2'-3"
2'-3" 2'-3"
2'-3" 2'-3"
D D
2 2
F1 F1 F1 A
2'-3" 2'-3" 2'-3" 2'-3" 2'-3" 2'-3"
10'-9"
SHORTER SPAN
STEEL
2'-112" 2'-412"
2'-112" 2'-412"
2'-112" 2'-412"
2'-112" 2'-412"
A B C D E