Annexure B': (Scope of Work & Specifications)

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 6

ANNEXURE ‘B’

(SCOPE OF WORK & SPECIFICATIONS)

Specifications of the Works shall be as per the drawings, Technical specifications,


mentioned and as per the descriptions in the BOQ.
However, the following details to be referred as General Specifications of the Project.
Consultant / Client decision is considered as Final , in case of any deviations.

Item Remarks
Description
Excavation
Earth work excavation Upto required
depth and levels as per the design,
drawing and as per the site condition in all
kind of soils and earth mixed with fair
sized boulders, hard morum either
manually or by using machinery and in all
conditions such as dry, wet, slurry etc.,
disposal and depositing the excavated
soil in the premises or disposing it outside
as directed.(Note: The work is including of
site leveling clearing the bushes, dressing
after the excavation and ramming for
surface ready for laying of PCC.
Anti Termite treatment to be
Earth filling up to floor levels as per the
PLINTH FILLING done before carrying out
drawing in inside the plinth of the building
any filling activities.
with good morum soils. Compaction of the
earth with water and vibrating plate
compactor. Filling and compaction upto
proposed floor level depending upon the
levels of site and road (Consolidation &
Compaction shall be done as per IS
standards).
R.C.C. framed structure on footings over MAKE:
FOUNDATION &
hard strata by using reinforced steel and
STRUCTURE STEEL :
cement of reputed make, including
RADHA/JAYRAJ/DHANALAK
placing the electrical conduiting, as per SHMI
Structural Engineers design. This
includes PCC, Shuttering, Supply of steel, CEMENT
Bar bending, Installation, supply and :
laying of concrete including curing. ULTRATECH/BIRLA/PENN
A
Sand and Metal will be used of the best
quality. Design mix report to be submitted ELECTRICAL CONDUITING
before first concrete casting for client :
approval. Reports of strength of concrete FINOLEX/SUDHAKAR
will also be submitted after 28 days of
casting for all slabs. Makes and brand of the
materials shall be as per
Consultant /Client approval

1
Make and technical
BRICKWORK EXTERNAL :
specifications such as
Brick Masonry with 200mm thick NCL strength, sound absorption
make AAC blocks. levels of the block should
be approved by
INTERNAL : Consultants / Client
Brick Masonry with 115 mm thick Red
clay bricks.(Note: including all kind of
RCC like CC beds, hole fasteners, lintels
and chajjas etc.,)

Approved and branded


PLASTERING INTERNAL:
make of Water proofing
Double coat cement plaster with compound to be added
ARKRETE ready mix plaster. while executing external
plastering works.
EXTERNAL :
Double coat sand faced cement
plastering / as per Architect’s choice with
Recron 3S polyester fiber, waterproofing
compound.
(Note: GI wire mesh to be used at
junction of concrete and brick/block
masonry/over conduit chased surfaces
and other required area)
PAINTING
INTERIOR WALLS:
Painting with applying one coat of Primer
( Asian Trucare(I) ), two coats of
Emulsion paint ( Asian Premium ) on 2
coats of wall putty ( JK or Birla)
EXTERIOR WALLS :
Painting with applying one coat of Primer
(Asian Trucare(E) ) , 2 coats of putty
wherever required and two coats of Damp
proof Apex paint ( Asian Apex ) as per
colour pattern given by the architect.
Material shall be as per
FLOORING : ROOMS : Flooring with 600 x 600 x
Client’s and consultants
12mm thick vitrified tiles over bed of
choice.
CM(1:4),50mm thick base coat and neat
gray cement slurry of honey like spread at
the rate of 3.3kg/sqm ( MAKE :SOMANY )
(BASE PRICE : 40/-)
CORRIDORS: laying of polished Granite
of 20mm thick over a bed of cement
mortar (1:4) 30-40mm thick and neat gray
cement slurry of honey line spread at the
rate of 3.3kg/sqm Spacing shall be as per the
Architectural intent and
STAIRCASE AND LOBBIES : Epoxy grouting to be done
Black Granite or equivalent for threads, in all the wet areas.
2
lobbies and skirtings and Sadharali
Granite for risers. (BASE PRICE : 100/- )
BATHROOMS :
Flooring with 300mm x 300mm anti-skid
tiles and Wall Cladding with 300mm X
600mm ceramic tiles over bed of CM(1:3)
base coat and neat gray cement paste
spread at the rate of 3.3kg/sqm. ( MAKE :
SOMANY ) (BASE PRICE : 60/-)
DOORS & MAIN DOORS AND INTERNAL DOORS Colour and pattern as per
WINDOWS : Medium Teak Wood Frame with flush client/ consultants choice.
shutter ( both side laminate ) doors of
sizes given by the architect in the
schedule.
TOILET DOORS :
Medium Teak Wood Frame with flush ( Edges to be properly
shutter with laminate on the outside and treated to avoid gaps and
aluminium sheet on the inside as per door entry of water)
schedule
Mosquito mesh and safety
WINDOWS: UPVC windows as per sizes,
grills to be included in the
specifications given by the architect.
Windows.
Fixed and air gaps filled with silicon
material. MAKE : NCL, ELEGANT

WATERPROOFING Waterproofing Treatment of Roof Should be as per


Terrace. Consultant’s approval and
strictly as per
1. Scrapping and cleaning the Roof
Manufacturer’s
Terrace surface thoroughly from dust, dirt
recommendations)
cement slurry etc. by means of wire
brush, chisels, scrappers, water etc.
2. Painting with acrylic polymer based Methodology should be
water impervious slurry coating Hind approved by Consultants /
Crete Plus WPM in two (2) coats. Client., if not alternative
method to be followed
Provision of protective overlay of average
without any additional cost.
40 mm thick Screed concrete of
proportion (1 cement: 2 sand: 4 stone
chips) over the entire chemically treated
surface maintaining a slope 1 in 100 (or)
directed my consultant towards the rain
water outlet.

Waterproofing Treatment of Toilet

1. Cleaning the R.C.C floor slab by wire


brush, chisel to make it free from all loose
material, depositions etc. Methodology should be
3
2. Application of 1:4 cement sand plaster approved by Consultants /
over the brick wall below the floor level Client., if not alternative
and above the sunken slab level. The method to be followed
brick wall will be provided with plain without any additional cost.
pointing with cement mortar before
plastering. The floor wall junction to be
rounded off with cement mortar. 10 years Warranty for all
water proofing works to be
3. Applying two coats of Hind Crete Plus
provided.
WPM admixed with cement in the ratio
1:2 ( 1 part Hind Crete Plus WPM : 2
parts cement) over the R.C.C sunken slab
and wall up to a height of 200 mm above
the desired finished floor level.
4. Ponding and testing the waterproofing
treatment after 48 hours curing by
sprinkling water.

Fitting of PVC pipes, conductors, cables, MAKE :


ELECTRICAL
junction boxes, Panel boards,MCB
PVC Pipes :
M.S Boxes, wiring, switchboards, exhaust
SUDHAKAR/ FINOLEX
fans, fans and lights as per architect
design. External lighting such as gate Conductors : HAVELLS/
lamps and focus lights, signage lights and FINOLEX
external landscaping lights all around the
Junction Boxes :
building will be provided.
ANCHOR/ MILLON/ GOLD
Earth pits and proper earthing provisions MEDAL
to be made by Contractor for machines /
MCB : HOGER/
building wherever required.
SIEMENS
(Note: Transformer to Panel Board power
Wiring : HAVELLS/
supply will be in our scope, distribution
FINOLEX/ POLYCAB
from Panel to Internal and External is in
the contractor scope) Switchboards :
HAVELLS/ GOLD MEDAL/
ANCHOR
Fans :
CROMPTON/ BAJAJ
Tube Lights : PHILIPS/
BAJAJ

PLUMBING
All fittings, plumbing lines and sewage
pipelines as per Architect’s design shall
be as follows :

PVC PIPES AND FITTINGS :


SUPREME/ ASHIRWAD
WASH BASINS :
HINDWARE/ JOHNSON
EWC WITH FLUSH TANK :
4
HINDWARE/ JOHNSON
URINALS :
HINDWARE/ JOHNSON
PILLAR/BIB/STOP COCKS :
PLUMBER/ JAGUAR

NOTE
All low side Electrical and complete
plumbing works including all type
of chambers, collecting pits and
rain water recharge pits
construction are in the scope of
the Contractor.
Highside works such as Transformer,
connection charges are in Client
scope.
All Pipes to be concealed and fixed
properly, wherever specified and
required by Client / Consultant/
Architects
The rain water from the terrace & open
RAIN WATER
areas will be collected through rain water
DISPOSAL
pipes, which will be discharged into the
rain water harvesting pits to recharge the
underground water.

WATER SUMP
to be constructed beneath the ground as
AND SEPTIC TANK
per the drawings and location given by
the architect.

DRAINAGE
SWR Pipes from the septic tank to the
drain shall be installed, taking levels of
drain into consideration, at sites where
drain is available.

MS WORKS 1. SS RAILING ( Grade 304) : Basic


design with 3 feet height, will be
installed all along the staircase .
2. GRILLS FOR WINDOWS : Grills
as per architects design made of
MS bars, painted and fitted.
3. MS GATE : 12 Feet wide gate as
per architects design with BJP
logo embossed on it.
ELEVATION : All MS works in elevation
as per architect’s elevation details
COMPOUND WALL Design Intent and
Construction of compound wall ( 4 ½ feet
aesthetics of the wall shall
height brick wall with 2 ½ feet height RR
5
be as per Architect’s
masonary ) all around the building ( wall
design.
will be built 5 feet from the building on all
sides ). TOTAL LENGTH = 400 RFT

CLIENT’s SCOPE Note: If any client scope of


● Change of Land use
works executed by
● Municipal Permissions Contractor the charges will
be paid as per actual by
● Temporary electrical connection client on submission of
● Meters, Transformers proper documents or proof.
● Bore well
● Consultants fee