Professional Documents
Culture Documents
Dokumen - Tips - New Waterborne Technologies For The Formulation of The Formulation of Problem Solving
Dokumen - Tips - New Waterborne Technologies For The Formulation of The Formulation of Problem Solving
SAMECA PQ / OMNOVA
Seminar APT - March 2015
Company Confidential
OMNOVA Solutions at a glance
Engineered
Surfaces
Value-added Emulsion Polymers Functional &
28%
& Specialty Chemicals 24% Decorative Surfaces
• Coating Resins
• Paper Chemicals
• Carpet Chemicals
Weaknesses of Waterborne Façade Offer
o Adhesion on Chalky Substrate
o Alkali/Efflorescence Resistance
o Alkali/Efflorescence Resistance
PLIOTEC® SA 40
PLIOTEC® LEB 18
Exterior Masonry Coatings based
on Hydro PLIOLITE® 010
Thin Film Exterior Masonry Paints
~300nm
Film Formation with Hydro PLIOLITE®
Water
Polymers dispersed Solvent evaporation
evaporation Coalescence
in water and film hardening
It is not particle size that drives adhesion but the ability of the
particles to deform and to fuse together after the coalescence.
Adhesive tape
Acrylic paint Hydro PLIOLITE Acrylic paint Hydro PLIOLITE
• Acrylic paint does not penetrate into the substrate and is easily
removed by the adhesive tape
HP HP HP HP HP
• In practice, time pressures for completion of contracts often means very little
time for concrete to achieve full cure
• Key advantages
– APEO-free carboxylated styrene acrylic Typical properties PLIOTEC® SA40
dispersion
Total Solids (%) 48 + 1
– Excellent alkali & efflorescence resistance
pH 7.5 - 8.5
– Excellent adhesion to concrete
MFFT (°C) 28°C
– Good water resistance
Tg (°C) 33°C
– Excellent pigment binding capability
Particle size 130 nm
– Odorless
• Formulation Guidelines
– PLIOTEC® SA40 requires no particular precautions, except to avoid raw materials
with possible negative influence on water sensitivity
– In order to provide the best barrier effect, solid content and paint viscosity would
have to be adjusted to ensure a relevant film thickness (min. 60 mm DFT)
– The masonry primer should be formulated below CPVC. OMNOVA extensive
formulation work has demonstrated that a PVC in the range of 30-40% provides
the optimum performance on fresh concrete
Starting Formulation WB ARP 02
WB ARP 02 % w/w
Water 3.60
PLIOTEC® SA40 20.80
Dispersing Agent 0.40
Amine 0.20 Characteristics
Antifoam agent 0.10 Specific gravity 1.41
Titanium Dioxide 7.40 PVC 39.6 %
Calcium Carbonate 5µm 13.60 PVC / CPVC 0,65
Calcium Carbonate 10µm 15.20 Volume solids 53.4 %
Talc 7.00 Weight Solids 66.1 %
PLIOTEC® SA40 26.50 VOC content 25 g/L
Coalescing Aids 1 0.80 ICI Viscosity 0.21 Pa.s
Coalescing Aids 2 0.80 MFFT - 2°C
Plasticizer 2.90 Spreading rate 160 g / m²
Antifoam agent 0.10
Associative Thickener (high Shear) 0.20
Associative Thickener (low Shear) 0.40
Alkali Resistance on Fresh Concrete
• Scope
The ability of a primer to resist high alkalinity of
fresh cement mortar can be checked in the
laboratory by using a simple visual test
• Scope
Efflorescence (formation of unsightly salt deposits
on the surface of the applied coating) is a common
problem since many masonry substrates contain
soluble salts either from the materials used in
their construction, or from high salt content in the
groundwater which can easily migrate up the wall
• Test Method
– The method consists of applying the coating (in
2 coats / 24h between coats) to porous clay Example of porous clay brick
bricks, leaving a few centimeters at the bottom
of the brick uncoated
– After 24h of drying, the bricks are placed in a
saturated salt solution for several weeks,
adding water or salt to the solution from time to
time to ensure that the level remains constant
– Changes in film appearance (blisters, salt
deposits, cracking, etc.) are observed up to a 4
weeks
No salt deposits along the porous clay brick Effective barrier to Efflorescence
with Primer based on PLIOTEC® SA40
Conclusion
• Role of surfactants
– Surface tension reduction of a liquid
– Reduction of interfacial tension between two liquids or a solid and a liquid
• Negative effect
Surfactants
Water absorption
Water sensitivity
Mobility
Hydrophilic
zone and
transport through the film
Tendency to congregate
Problem of Exudation
Formation of condensation on
freshly painted exterior facade
due to temperature falling
below dew point.
When condensation
subsequently dries, surfactants
are deposited on the surface of
the paint, causing staining or
discoloration.
An example of discoloration due to
surfactant exudation from the coating
Resistance to Exudation and Efflorescence
• Polymer Tg
– Main parameter influencing dirt pick-up
High Tg High dirt pick-up resistance
– Crack-bridging property at ambient temperature
Tg must be below 15°C
PLIOTEC LEB 18
Monomeric composition adjusted so as to achieve good balance between
yellowing and chalking resistance in 35% to 60% PVC range
Tg = 12°C to combine dirt pick-up resistance and crack-bridging ability
Polymer structure providing built-in flexibility
PLIOTEC® LEB 18
• Characteristics
– Modified acrylate copolymer
– APE free
– No added formaldehyde
• Typical Properties
– Particle size = 120 nm
– Tg = 12°C
– MFFT = -1°C
– Viscosity (60rpm / 25°C) = 400 cPo.
– Solid Content = 42.5%
– pH = 9
– VOC = 20 g/L
– Film formation: coalescence and solvent evaporation
Evaluation of Latex Performance
Test Method
Application of the paint by brush
to the exterior of plastic cans
(375g/m²)
After 16 hours of drying, cans are
filled with water and ice (4°C)
Cans are placed in a climatic
chamber at 25°C and 90% relative
humidity for a period of 90 min.
Leachate collected in a cup
positioned below the can
Degree of leaching is measured
weighing the exudates after
evaporation during 4.5 hours at
60°C
Evaluation of Latex Performance / Exudation
2,5
Quantity of Exudate (g/m²)
2,0
1,5
1,0
0,5
0,0
New LEB StyAc1 StyAc2 StyAc3 Ac
Tg12 Tg15 Tg20 Tg22 Tg25
Evaluation of Latex Performance / Exudation
2,5
Quantity of Exudate (g/m²)
2,0
1,5
1,0
0,5
0,0
New LEB StyAc3 StyAc3 + EL StyAc3 + EL Ac Ac + EL Ac + EL
Tg12 Tg22 Tg12 Tg4 Tg25 Tg12 Tg 4
Main Applications
In this last part, focus is made on High Build Coatings, being by nature
more prone to surfactant leaching problem
High Build Exterior Masonry Coatings
• Decorative and waterproofing renovation of façade
• Old and cracked or micro-fissured façade
• High technical characteristics:
– Excellent build
– Suitable flexibility
– Great versatility in use
– Associated to a primer on new masonry and direct application over old coatings in
good conditions
StyAc
#2 E4V2W3A1 1,25 54 <40
Siloxane Modified
StyAc
#3 E4V2W3A1 1,40 54 <40
Siloxane Modified
StyAc
#6 E4V2W3A2 1,50 60 <20
Siloxane Modified
Acrylic
#7 E4V2W3A2 1,45 55 <20
Siloxane Modified
Modified
FPS306 E4V2W3A1 1,52 55 14
Acrylate
5,00
4,50
4,00
Quantity of Exudate (g/m²)
3,50
3,00
2,50
2,00
1,50
1,00
0,50
0,00
Paint #1 Paint #2 Paint #3 Paint #4 Paint #5 Paint #6 Paint #7 FPS306
Evaluation of Coatings / Resistance to Efflorescence
Test Method
Application of acrylic textured coating on fiber cement, then 1 week of drying at room temperature
Application of the coating to be tested at 375g/m², and 20 min of drying at room temperature
Shower test during 2 min.
Paint #7 FPS306
NO OK OK
Conclusion