Pressure and Temperature Controls

Application Info

SBA: Food & Beverage


Application: Control of Tank pressure
Products: MBS Sanitary

Application description One of our subsidiaries has delivered a


number of sanitary MBS 33 to a producer of
soft drinks.
The factory is a bottling plant for mineral
water, and the purpose of the pressure
transmitters is to monitor the pressure of
pressurized storage and buffer tanks.

Tanks, piping and fittings are in AISI 316


stainless steel, and so must be the parts of all
components in contact with the medium.

Moreover, the couplings must be of the


hygienic type, and the standard of this factory
is ISO-clamp.

Cleaning is made with steam at 120°C (SIP,


Steaming In Place), and for this reason it is
necessary to use pressure transmitters which
can withstand such high temperatures.

The solution for this application has been to


put on 12 pcs. of sanitary MBS 33 with cooling
tower and clamp connection.

The detailed specification of the application


diagram is shown below.

Application diagram

Product advantages The main technical reason for selecting According to our subsidiary the other reason
Danfoss as a supplier is for success is:

Performance Flexibility
A good accuracy combined with a low We were able to offer exactly the type of
temperature drift. connection and material specified by the
customer

May 1998 IA.20.O1.02


Applicatlon Info Food & Beverage, control of tank pressure, MBS sanitary

Potential customers • Producers of tanks for the beverage and


soft drink industries (see the Kompass
code)

• Soft drink producers

• Breweries

Kompass codes 35-270, 35-280 Boilers and tanks


(part 1 and 2)

Subsidiaries responsible Danfoss S.r.l., Torino, Italy (ITSWC)


for the customer