Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

TECHNICAL BULLETIN

PRELIMINARY
®
ALPHA JP-501
LEAD-FREE, LOW TEMPERATURE, ZERO HALOGEN, NO CLEAN SOLDER PASTE
FOR JET PRINTING

DESCRIPTION
ALPHA® JP-501 is a lead-free, no-clean solder paste designed for use in Jet Printers. ALPHA® JP-501 features a
rheology capable of standard dispensing or jetting. The low temperature, lead-free alloy in ALPHA JP-501 has a
melting point of 138°C, and has been successfully used with peak reflow profiles between 155 and 190°C. The flux
residue from ALPHA JP-501 is clear and colorless and is formulated to offer high electrical reliability in a zero halogen
flux formulation.

Outstanding reflow process window delivers good soldering on CuOSP, lead free HASL, Immersion Silver, Immersion tin
and ENIG surface finishes. Additionally, ALPHA JP-501 is rated ROL0 per IPC J-STD-004.

All components used with ALPHA JP-501 must be lead-free to eliminate the formation of tin/lead/bismuth intermetallic
which has a melting point under 100ºC.

FEATURES & BENEFITS


 Reduces energy consumption in reflow ovens versus standard lead free alloys.
 Low temperature reflow profiles may enable the use of less expensive printed circuit board substrates, when
appropriate.
 Excellent deposit consistency with high process capability index across all board designs.
 Designed for use with the MYDATA® MY500 Jet Printer.
 Zero Halogen (no halogen intentionally added to the formulation)
 Wide reflow profile window with good solderability on various board / component finishes.
 Excellent solder and flux cosmetics after reflow soldering
 Reduction in random solderballing levels, minimizing rework and increasing first time yield
 Excellent pin-test yield for single and double reflow.
 Excellent reliability properties, zero halide material
 Capable of high reflow yield without the use of nitrogen

PRODUCT INFORMATION
Alloy: 42%Sn/57.6%Bi/0.4%Ag
Powder Size: Type 5, (15-25μm per IPC J-STD-005)
Residues: Approximately 6% by (w/w)
Packaging Sizes: Iwashita 30 cc dispensers
Flux Gel: JP-501 Flux Gel is available in 10cc and 30cc syringes for rework applications.
Lead Free: Complies with RoHS Directive 2002/95/EC.

APPLICATION
ALPHA JP-501 is formulated for dispensing and jet printing applications.

SAFETY
While the ALPHA JP-501 flux system is not considered toxic, its use in typical reflow will generate a small amount of
reaction and decomposition vapors. These vapors should be adequately exhausted from the work area. Consult the
most recent version of the MSDS at www.alphacpmd.com for additional safety information.

109 Corporate Blvd., South Plainfield, NJ 07080 , 1-800-367-5460, alpha.cooksonelectronics.com


STORAGE
ALPHA JP-501 should be stored in a refrigerator upon receipt at 0 to 10C (32-50°F). ALPHA JP-501 should be
permitted to reach room temperature before unsealing its package prior to use (see handling procedures on page 3).
This will prevent moisture condensation build up in the solder paste.

JP-501 TECHNICAL DATA


CATEGORY RESULTS PROCEDURES/REMARKS
CHEMICAL PROPERTIES
Activity Level ROL0 = J-STD Classification IPC J-STD-004
Halide free (by titration).
IPC J-STD-004
Halide Content Passes Ag Chromate Test
EN14582, by oxygen bomb
Pass, Zero Halogen - No halogen
Halogen Content combustion, Non detectable (ND) at <
intentionally added
50 ppm
Copper Mirror Test Pass IPC J-STD-004
Pass, (No Evidence of Corrosion) IPC J-STD-004
Copper Corrosion Test Pass, (No evidence of corrosion) JIS Z 3197 -1999 8.4.1
ELECTRICAL PROPERTIES
SIR IPC J-STD-004A
o Pass
(IPC 7 days @ 85 C/85%RH) 8
Pass = 1 x 10 ohm min
SIR Bellcore GR78-CORE
Pass
(Bellcore 96 hours @ 35°C/85%RH) 11
Pass = 1x10 ohm min
Electromigration 10
Final Reading > 10 ohms
o
(JIS Z 3197 @ 85 C/85%RH 48V DC JIS Z 3197 1999
No Migration After 1000 hrs = Pass
1000 hours)
PHYSICAL PROPERTIES (85-5-M08 Viscosity - Malcolm viscometer @10 RPM, 25°C)

Color Clear, Colorless Flux Residue


2
Pass - Change of <1g/mm over 24
IPC J-STD-005
hours at 25% and 75 % RH
Tack Force vs. Humidity
(t = 8 hours)
Pass - Change of <10% when stored
o JIS Z3284 Annex 9
at 25±2 C and 50±10% RH
85% metal load, Type 5 designated
M08 for printing
Viscosity Malcom Spiral Viscometer; J-STD-005
Viscosity (Typical) 800 poise at 10
RPM Malcom
Solderball Acceptable IPC J-STD-005
Modified IPC J-STD-005 (10 min
Slump Pass 100°C)
Pass JIS Z-3284-1994 Annex 8

Rev 11.05.12
109 Corporate Blvd., South Plainfield, NJ 07080 , 1-800-367-5460, alphacpmd.com
JP-501 Processing Guidelines
STORAGE & HANDLING Jetting or Dispensing REFLOW (See Figure #1) CLEANING
Refrigerate to guarantee stability Designed for use with MYDATA® ATMOSPHERE: Clean-dry air or ALPHA JP-501 residue is
o o
at 0-10 C, 32-50 F AG 01 Ejector System. nitrogen atmosphere. designed to remain on the board
after reflow.
Shelf life of refrigerated paste is 6 PROFILE: See Figure #1 If reflowed residue cleaning is
months required, ALPHA BC-2200
Acceptable reflow/coalescence aqueous cleaner is
Paste can be stored for 2 weeks and IPC Class III voiding were recommended.
at room temperature up to obtained with the given profile For solvent cleaning, agitation for
o o
(25 C/77 F) prior to use 5 min in the following cleaners is
Note: Refer to component and recommended:
When refrigerated, allow paste board supplier data for thermal - ALPHA SM-110E
TM
container to warm to room properties at elevated - Bioact SC-10E
temperature for up to four hours. temperatures. Lower peak - Kyzen Micronox MX2501
o o
Paste must be > (19 C/66 F) temperatures require longer TAL
before processing. Verify paste for improved joint cosmetics. Misprints and stencil cleaning
temperature with a thermometer may be done with:
o o
to ensure paste is (19 C/66 F) or - ALPHA SM-110E
greater before set-up. Printing - ALPHA SM-440
can be performed at - ALPHA BC-2200
o o TM
temperatures up to (29 C/84 F). - Bioact SC-10E cleaners.

Do not remove worked paste


from stencil and mix with unused
paste in jar. This will alter
rheology of unused paste.

These are starting


recommendations and all
process settings should be
reviewed independently.

Working conditions:
19 - 29°C on the stencil.

BoactTM is a registered trademark of Petroferm, Inc.

General Reflow Profile Guidelines


Parameter Guideline
Atmosphere Air or N2
o
SnBiAg (42/57.6/0.4) alloy 138 C (near eutectic)
Setting Zone Optimal Dwell Period
40°C to 138°C 2:10 - 4:00 minutes
125°C to 138°C 0:30 - 1:30 minutes
100°C to 138°C 1:15 - 2:00 minutes
TAL (138°C) 0:30 - 1:30 minutes
Peak temperature 155 °C - 180°C
Joint cool down rate from 170°C 3°C - 8°C/sec

Rev 11.05.12
109 Corporate Blvd., South Plainfield, NJ 07080 , 1-800-367-5460, alphacpmd.com
Figure #1 – JP-501 Reflow Profile Envelope

Rev 11.05.12
109 Corporate Blvd., South Plainfield, NJ 07080 , 1-800-367-5460, alphacpmd.com