A307 Ius DPG DS 2202

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

1 Tag Number IUS-UB12-DPG -2202

2 Service NG Differential Pressure across strainer-2


GENERAL 3 Line No CONICAL STRAINER
4
5
6 Fluid Natural Gas
7 Max. Pressure Max. Temperature kgf/cm²-g °C
PROCESS 8 Oper. Pressure Oper. Temperature 3 kgf/cm²-g 40 °C
CONDITIONS 9 Pulsation Vibration No No
10
11
12 Type Direct
13 Range Min. Max. 0 kgf/cm² 1 kgf/cm²
14 Window Material Shatter-Proof Glass
15 Enclosure Type Weather Proof, IP 65
16 Mounting Pipe Mounted
17 Dial Size 150 mm
18 Dial Color White With Black Figures
19 Case Material SS 304
GAUGE 20 Bezel Ring Ring Material Bayonet / Screw Type
21 Blow-Out Protection Yes
22 Zero Adjustment Internal Micrometer adjustment
23 Pressure Element Type Bourdon
24 Pressure Element Material SS 316
25 Socket Material SS 316
26 Connection Size 1/2" NPT(M)
27 Connection Location Bottom/Back
28 Movement Material SS 304
29 Nominal Accuracy +/- 2% FSD
30 Over range Protection 130% of Design Static Pressure
31
32 Type NA
33 Process Connection NA
34 Size and Rating NA
35 Facing and Finish NA
36 Gasket and Backup Flanges NA
DIAPHRAGM 37 Capillary Length NA
SEAL 38 Capillary Material NA
39 Flushing Connection No
40 Armour Type and Material NA
41 Mounting Acess for 2" NB Pipe NA
42 Wetted Parts Material Other Material NA NA
a Pulsation Dampener NA
b Syphon C Type
c Pressure Limit Valve
OPTIONS d Liquid Filled Casing
e Vacuum Protection
f Spacer Ring (Drip Ring)
g Solid Front
50 Manufacturer RMG AUTOMETERS
51 Model DPG-DS-15-S4-S-S-A-15NTM-0-1-A-15KG/CM2-L
PURCHASE 52 Purchase Order Number 107377
53 Price Item Number
54 Serial Number
Notes: See notes

INSTRUMENT SPECIFICATION
Pressure Gauge
Project: IREP, BPCL-KR
Job No.: A307
0 VAC 1/25/2016 Issued for Comments/Approval Unit: IUS Sheet 1 of 2
No. By Date Description Code: 100 Doc. No.: A307-IUS-DPG-DS-2202 Rev.: 0
Tag Number : IUS-UB12-DPG -2202

1.Over Range protection required if Maximum Operating Pressure exceeds the over range protection pressure.Over Range Protection Pressure shall
correspond to Maximum Static Pressure. All Differential Pressure Gauges shall be suitable for Maximum Static Pressure in both legs.

2.Static Pressure:10 Kg/cm²g.

3.Design Pressure:15 Kg/cm²g.

4.Design Temperature:100° .

INSTRUMENT SPECIFICATION

Pressure Gauge

0 VAC 1/25/2016 Issued for Comments/Approval Sheet 2 of 2


No. By Date Revision Code: 100 Dwg. No.: A307-IUS-DPG-DS-2202 Rev.: 0