When a fault is active, the parking brake light flashes a sequence of long flashes followed by
short flashes. The following table is a list of possible codes for the ECM. After determining the
flash codes, refer to the corresponding test procedure for more information. Perform the
procedure that corresponds to the flash code.
Table 1
Diagnostic Screen Name /
Flash
Diagnostic System Description Possible Causes
Code
Procedure
Sensor is transmitting
"CP_Prop_Hndl_Flt"
Propel Control Handle: PWM internal fault signal.
Refer to Diagnostic System
1-2 signal from handle sensor is Incorrect calibration.
Procedure, "Propel Control
out of valid working range. Open circuit. Short to
Position Sensor - Test"
battery or ground.
Offset configuration
dongle is installed on
"CP_CCW_Offset_Flt"
CCW Offset: Solenoid is not machine without
Refer to Diagnostic System
2-8 detected, or is shorted to offset. Open circuit.
Procedure, "Drum Offset
battery or ground. Short to ground.
Left Solenoid - Test"
Faulty coil. Poor
connection.
2-9 "CP_CW_Offset_Flt" CW Offset: Solenoid is not Offset configuration
Refer to Diagnostic System detected, or is shorted to dongle is installed on
Procedure, "Drum Offset battery or ground. machine without
Right Solenoid - Test" offset. Open circuit.
Short to ground.
Faulty coil. Poor
connection.
"CP_Brake_Solenoid_Flt"
Brake Solenoid: Solenoid is not Open circuit. Short to
Refer to Diagnostic System
3-1 detected, or is shorted to ground. Faulty coil.
Procedure, "Parking Brake
ground. Poor connection.
Solenoid - Test"
"CP_SHUNT_Flt"
Solenoid of the Valve for the Open circuit. Short to
Refer to Diagnostic System
3-2 Shunt: Solenoid is not detected, ground. Faulty coil.
Procedure, "Propel
or is shorted to ground. Poor connection.
Interlock Solenoid - Test"
"CP__H2O_Timer_Flt"
Incorrect resistance
Refer to Specifications
potentiometer.
Systems Operation Testing Water Timer– valid working
4-1 Incorrect calibration.
and Adjusting, KENR3615, range CB-564D and IRH only.
Open circuit. Short to
"Water Spray Timer -
battery or ground.
Calibrate"
"CP__H2O_Mode_Flt"
Water Mode– Both water spray Open circuit. Faulty
Refer to Diagnostic System
4-3 mode inputs are open circuit. pump mode selects
Procedure, "Water Pump
"CB-564D" and IRH only. switch.
Selector Switch - Test"
"CP_Neutral_Flt"
Open circuit. Short to
Refer to Diagnostic System Speed Valve: The output has an
battery or ground.
5-2 Procedure, "Propel Shift open or short to battery /
Faulty coil. Poor
Solenoid - Test" ground. CB-564D and IRH only
connection.
( CB-564D and IRH only)
"CP_Backup_Alm_Flt"
Backup Alarm: Backup alarm
Refer to Diagnostic System Open circuit. Short to
5-4 or backup alarm relay not
Procedure, "Backup Alarm ground. Blown fuse.
detected.
Relay - Test"
Incorrectly adjusted
"CP_ NEUTRAL _Flt" Neutral: The neutral
proximity switch.
Refer to Diagnostic System indications of the handle
Faulty connection.
5-5 Procedure, "Propel Control sensor and the proximity
Faulty handle position
Proximity Switch - Test" sensor do not agree. (CB-564D
sensor. Faulty
(CB-564D and IRH Only) and IRH Only)
proximity sensor.
"CP_VibeFwd_Flt"
Vibe Forward: Pump solenoid Open circuit. Short to
Refer to Diagnostic System
6-2 is not detected, or is shorted to ground. Faulty coil.
Procedure, "Vibratory
battery or ground. Poor connection.
Forward Solenoid - Test"
"CP_VibeRev_Flt"
Vibe Reverse Pump solenoid is Open circuit. Short to
Refer to Diagnostic System
6-3 not detected, or is shorted to ground. Faulty coil.
Procedure, "Vibratory
battery or ground. Poor connection.
Reverse Solenoid - Test"
"CP_VibeHiLow_Flt"
Vibe Hi/Lo – Invalid signal
Refer to Diagnostic System Vibe configuration
6-4 detected by ECM. (CB-564D
Procedure, "Vibratory setting not correct
Only)
Amplitude - Test"