Download as pdf
Download as pdf
You are on page 1of 5
SIZE MASTERS CALIBRATION SERVICES Final Plot No. 123, Lane No. 10, Ramtekdi Industrial Estate, Hadapser, 411 019. (INDIA) Tel. : +91 9890644445, 8297644445, E-mail : kiranzanwar@yahoo.com / smoscalibration@gmail.com Punt CERTIFICATE OF CALIBRATION Certificate No. 2019 / 38461 /05 | Date of Issue — 16/11/2019 Page No. 1 of2 ] ULR: CC246019400001551F Discipline: Mechanical Product Group: Force | NAME OF CUSTOMER MACHINE DETAILS ] Type: Universal (Uniaxial) 1S: 1828(Partl): 2076 | ‘Mis. Walchandnagar Testing Machine. cence 1807500-1: 2018 | Industries Ltd. Make: FIE Procedure No. W214 | Walchandnagar, Tal - Indapur, | Model: UTE - 60 Calibrated On’ 14/11/2019 | Dist. Pune - 413 114, ieee Agreed Due Date | 13/11/2020 | a Maharashtra. Max. Cap. : 600 KN Calibrated By DG Nanaware | Mode of cal": Gompression_| Location: LAB | Other Details: Make / Model SR.NO./IDNO. Capacity Pressure Call NAINA. NAINA 00 kN Digital Indicator FIE/ UTE - SERVO NAINA, Details of Force Proving Instrument used for calibration: Make/ModeVCapacity ADI Artech/0210/50 kN | ADI Artech/90310/500KN Sr. No/Gauge Sr. No. NT-LIM05/NT-LE-105 | 365316 14687 / 14687 Calibration Cerificate No. | FRV09/16/10808 FRIMQT/OTAS 17080619/D1 0510-496 & Date. & ct 29/09/2018 & at 31/1272017 & at 25/112017 | Next Calibration due 29/11/2020 02/03/2020 23/01/2020 | Calibrated at Temp. 24°C 24°C 231°C | UL IM, at 95.45% C.L. £0.08 % atK=2 0.080 % at K=2 £0.12 % at K= i FRI, Ichalkaranji FRI, Ichalkaranji | Traceability to NPL through | qasi-CC2029) (NABL-CO-2029) ee Observations Force Standard] Temp. Avg. oF Proving | Test Fore® | instrument | Corrected | Observed | %Errorof | %Erorof | ULL. Instrument | (gn) Read. | Std.Read | Read. Accuracy | Repeatability | % (2) used ( (Div) (Div) (Div) | Range: 0- 600 KN Gerlified Range: 10 600 KN Temp. 227° L.C.: 0-120 KN: 0,03 KN, 120-240 KN: 0.06 KN & 240-600 KN: 0.15 kN 10 10004 : 10069.33 0.85 0.20 018 | on 20 20007 : 2011167, 052 0.02 018 | 49985 : 50188.67 0.35 ona 018 | ae. Ls (ANAWARE Calibrated By Note : This certificate is issued subject to conditions stated overleat. SIZE MASTERS CALIBRATION SERVICES Final Plot No. 123, Lane No. 10, Ramtokdi Industrial Estate, Hadapser, Pune - 411 013. (INDIA) Tel. : +91 9890644445, 8237644445 E-mail : kiranzanwar@yahoo.com / smoscalibration@gmail.com CERTIFICATE OF CALIBRATION Continuation of Report No. : 2019/ 38461 /05._ | ULR: CC246019400001551F _| Page, 2 of2 Observations. - Proving | Test Force tnarumert | canetea | ontenea %emerof | %emorot | ULM | Instrument | (gi) Read. | Sti.Read | — Read, ‘Accuracy | Repeatability | 9% (2) used (Dv) (Div) (div) Range: 0- 600 EN Certified Range: 10-600 KN Temp. 227°C | L.C.: 0-120 KN: 0.03 KN, 120-240 KN: 0.06 KN & 240-600 KN: 0.15 kN UY 50 49.22 - 49.21 -0.03 ore | 018 se’ [100 99.47 - 99:37 0.10 00s | one | 150 149.69 : 149.87 0.42 0.08 a | 160 10020 - 10083.00 063 0.16 0.18 200 13356 : 13385.00 022 0.07 018 3o00KN [__300 20029 = 20133.67 052 010 | ote te. 400 26702 : 26646.67 0.24 026 | o2t 500 33375 : 3e2e86.67 | -0.26 0.04 ote | 600 40048 : 39931.67 0.29 0.04 o18 | Resolution: 0.03 KN ‘Max. Observed Reading on removal of force: O.00KN | Max. Relative Resolution : 0.30 % Max. Zero Error: 0.00 % | Note: Standard & Observed readings of 50 kN & 3000 kN Load Gell are In Div & 500 KN Load Cell are in kN. \ _U.I.M. is calculated with the coverage factor 2 corresponding to 95.45% confidence level Class of the machine: Class 1 Classification of the machine as per IS: 1828 (Part 1): 2015 & ISO 7500-1: 2018 Class of ‘Maximum Permissible value, % Machine Relative Error of. Range ‘Accuracy (a) [Repeatability (6) | Zero (fo) | Relative Resolution (a) 1 21.0 4.0 £01 05 2 £20 2.0 202 4.0 3 £3.0 3.0 £03 1.6 ES SE ‘NANAWARE 1 OX te vw. R . Calibrated By

You might also like