BENDING REINFORCEMENT
SHEAR REINFORCEMENT
file:///conversion/tmp/activity_task_scratch/589392188.xls 1
Ref. CALCULATIONS OUTPUT
NOTE:
v < 0.5vc ; SHEAR REINFORCEMENT NOT REQUIRED
0.5vc < v < (vc+0.4) ; MINIMUM SHEAR REINFORCEMENT REQUIRED
(vc+0.4) < v < 0.8(fcu)^0.5 ; SHEAR REINFORCEMENT REQUIRED
.: THEREFORE, SHEAR REINFORCEMENT REQUIRED
6 mm DIAMETER LINK
Asv = (∏ фlink² / 4) x 2 = 57 mm²
LINKS SPACING, SV
DEFLECTION CHECK
(L / d) basic = 20
BS 8110 M/Bd² = 3.62
CLAUSE SERVICE STRESS (fs) = (2 x fy x As req.) / (3 x As prov.)
3.4.6 = 230.97 N/mm2
TABLE 3.11 MODIFICATION FACTOR (MFTR) = 0.55 + (477-fs) / { 120 x [0.9 + (M/Bd²) ] }
TABLE3.11 = 1.00
CRACKING CHECK
BS 8110 NOTE:
CLAUSE
3.12.11
TABLE 3.28
S1 = 88 < 155 OK
S2 = 49.0 < 77.5 OK