CENTURY 2000

APPLICATION: MATERIAL TUBE: BRANDING:


¡ Low-permeation, anhydrous ¡ Extruded , high-grade, ¡ Green longitudinal mylar
ammonia transfer hose low-permeation EPDM stripe: CENTURY 2000 •
¡ Developed for use with nurse ANHYDROUS AMMONIA
tanks REINFORCEMENTS: 350 PSI
¡ Distinctly identified with a ¡ Multiple high-tensile textile ¡ Embossed stripe: N2000
bold green stripe braids • ANHYDROUS AMMONIA
¡ Branded with removal date MATERIAL COVER:
• 350 PSI MAX W.P. • * •
¡ Pro-rated six-year warranty ¡ Black abrasion and weather FOR AG. SVC. • REMOVE
for agricultural applications resistant EPDM HOSE BEFORE ** • 10001
only when coupled by an ¡ Cover is pin-pricked, which • *** • REFER TO INDUSTRY
approved distributer promotes better dissipation RECOMMENDATIONS INCL
of the anhydrous ammonia RMA/IP-11-2 FOR CARE
TEMPERATURE RANGE:
and assists in resisting cover
¡ -40°F to +180°F * Year of Manufacture”
blisters
¡ -40°C to +82°C ** Year of Manufacture plus
6 years
BURST PRESSURE:
*** Year-Month of
¡ Minimum 5:1
Manufacture

STANDARD LENGTHS:
¡ 100 feet, 30.5 meters

CENTURY 2000
maximum working minimum bend
ID OD weight
pressure radius
mm inch mm inch bar psi mm inch kg/m lb./ft.

9.5 3/8 22.9 0.90 24 350 63.5 2.5 0.49 0.33


12.7 ½ 26.2 1.03 24 350 76.2 3.0 0.58 0.39
19.0 ¾ 32.8 1.29 24 350 101.6 4.0 0.68 0.46
25.0 1 38.9 1.53 24 350 127.0 5.0 0.86 0.58
32.0 1¼ 44.5 1.75 24 350 139.7 5.5 1.00 0.67
38.0 1½ 53.8 2.12 24 350 190.5 7.5 1.31 0.88
51.0 2 69.3 2.73 24 350 279.4 11.0 1.95 1.31
All data at 68° F / 20° C

All information contained on this datasheet is subject to change without prior notice. GOODALL MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, IN-
CLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR COURSE OF PERFOR-
MANCE OR USAGE OF TRADE. Buyer/end-user is responsible for determining whether the Goodall product is fit for a particular purpose and suitable for
buyer’s/user’s method of use or application. Failure to follow procedures for selection, installation, care, maintenance and storage of hoses may result in
version 260914

the hose’s failure to perform properly and may result in damage to property and/or serious injury. Goodall or any of its affiliates or subsidiaries shall not be
subject to and disclaims any obligations or liabilities (including but not limited to all consequential, incidental and contingent damages) arising from tort
claims (including without limitation negligence and strict liability) or other theories of law.

www.goodallhoses.com