External Visual Inspection Form Tank ID Code
Part 4 (a): Information on Registered Facility
Name of Registered Facility
Address
Town Province
Postal Code: Phone Number
Person Conducting the Inspection
Transport Canada Facility Registration Number: Inspection Date (ddimmivy)
erenO mene
Name of Tank Owner:
Address:
Telephone Number.
Part 1 (c): Tank Data
's cataplate leoibie?
Photo taken of dataglate or copy on fe? | -- Yes “No
Rejection Crteria- Failure to meet the minimum standard requiremen
under 8620 5.1.6.1.5, where the dataplate shail be maintained In iegibe
condition and as required during an external inspection (7.2.1.4 [el).
Pericles Reker eee eed eee Omene
Tank ID;
‘Serial Number.
CRNIASME Designation:
MAW: *= PSI “kPa (chose one)
Temperature Rating ~ Fahrenheit ~ Celsius (choose one
Tank Specification ~" Non-spec “Spec (specify )
Year of Manufacture
Water Capacity ~ Gallons ~~ Litres (choose one)
Tank Material Steel
Shell Thickness. ~ Inches ~ Milimetres (choose one)
Head Thickn
= Inches ~~ Millmetres (chaose one)
Extemal Visual Inspection Form Page 1 of 8
Nurse Tank Safety Council of Canada - Quality Control Manual
Inspection and Testing Protocol - Issued 2013, Revision 5
72Tank ID Code
ies
Date of Last Test
Less than or equal to a 36-month period (in accordance to B620 Table 7.1, “Periodic
Inspection ang Testintervais"), The external inspection period may ve extended to 3 years
{or tanks outlined in CSA BE22, clause 6.3, specific requirement 56.
‘Markings on tanks must be legible (CSA 8620 7.2.1.1fel).
Record all test markings on tanks below.
‘Test Dates (mmiyy):
Safety
Requirements
Close proximity to Fresh Water; take note of wind direction (always approach upwind).
‘goggles: gloves; safaty boots: and NH3 protactive suit
General Information
for Quick Reference
Litres to US galons = x /3.77
US gallons to lires = X*3.77
kPa to PSI=X* 0.145,
PSI tokPa=X" 6.89
Nominal Thickness : Tank Body 375 in. (9.53 mm) for Westee! tanks
Tank Ends 222 in. (8.18 mm) for Westee! tanks
Consult wih manufacturer of other tanks for thelr thicknesses.
General Equipment
Required
Tadder, melal ruler, telescoping miror, metal scraper, wire brush, ard picks. Acaliper &
required only if certification for a “Thickness Test” is granted to the testing facility
Tank Preparation
“Accept ~ Action
Tank is free of any dirt and deoris that woule otherwise hinder any observations to tank
shell all external attachments (Le. water tank, safety kit, ete.) are removed,
List defects and locations below or use additional sheets if required.
‘Comments:
Extemal Visual Inspection Form Page 2018
Nurse Tank Safety Gouncil of Canada - Quality Control Manual
Inspection and Testing Protocol - Issued 2013, Revision 5Tank ID Code
Inspect enire aea of tank fordents, scrapes, distortions, gouges, bulges, cracks, signs of
leakage or any ather condition that might render it unsafe for transport (72.1.1 fa).
Rejection Criteria:
+ Defects less than the minimum thickness remaining under 2 cut dig, or gouge
Tank Shell Inspection (10% less than the nominal thickness) [7.2.2 2(a)]
Any dent wih a depth of more than 12.7 mm (0.6 in) where it includes a weld
~ Accept ~ Action (7.2.2.200)
Any dent with a deptn of greater than 10% oftne length of tne dent (7.2.22 fe])
Any structural defect (7.2.2.2 lel)
Any source of leakage (7.2.2 2ifl)
List defects and locations below or use additional sheets if required:
Inspect entre area of tank for corrosion, abrasions, and signs cf leavage or any oher
condition that might render it unsafe for transport (72.41 [a})
Rejection Criteria:
‘Accept “Action |+ Defects less than the minimum thickness remaining under a cut, dig, or gouge
(10% less man te nominal tnickness) (7.2.22 fa).
+ Any source of leakage (7.2.2.2 If).
List defects and locations below or use additional sheets if required:
Ensure all appurtenances (any fank pat or accessory that has no product containment
Tunction ard provides no structural supporto tank (Le. PRV guards, weld pad)) and
attachments, support structures, or connecting structures are nat damaged or correded so
435 10 affect Safe operation of the tank (7.2.11If)
Accept Action | Rejection Criteria:
+ Insludes any structural defect (72.22 fel)
+ Repairs made to liquid retaining components using overiay patches (7.2.2.2{a])
List defects and locations below or use additional sheets if required,
Extemal Visual Inspection Form Page 3 of 8
Nurse Tank Safety Council of Canada - Quality Control Manual
Inspection and Testing Protocol - Issued 2013, Revision 5