Professional Documents
Culture Documents
TCD-150-163 Di1
TCD-150-163 Di1
DOWN_RUN
Floor_Height_Table[1] start_enco
ADDRESS SDS OFFSET DATA
0x1154 Equivalent_Spec.Sds3_Bound 50
0x1156 Equivalent_Spec.Sds4_Bound 50
0x1158 Equivalent_Spec.Sds5_Bound 50
※ Comparing E/L speed and speed check data(each reducing speed
uniformly) after SD1D~7D operation,if E/L speed excesses speed 0x115A Equivalent_Spec.Sds6_Bound 100
check data error is detected.
0x115C Equivalent_Spec.Sds7_Bound 400
Point of ● Run CPU ● DI120-150
TCD 157~163 SD1~7(U) OVER SPEED Application
Detection ○ Speed CPU ● DI180-420
0
err_Detect
0x1150 Equivalent_Spec.Sds1_Bound 50
err_Detect & SD1U
TCD 157 0x1152 Equivalent_Spec.Sds2_Bound 50
0x1154 Equivalent_Spec.Sds3_Bound 50
0x1156 Equivalent_Spec.Sds4_Bound 50
0x1158 Equivalent_Spec.Sds5_Bound 50
※ Comparing E/L speed and speed check data(each reducing speed 0x115A Equivalent_Spec.Sds6_Bound 100
uniformly) after SD1U~7U operation, if E/L speed excesses speed
0x115C Equivalent_Spec.Sds7_Bound 400
check data error is detected.