1. The document provides troubleshooting steps for a detected speed error on TCD 169.
2. It first lists the point of detection and meaning, then provides 6 actions to take to resolve the issue, including checking wiring, voltage, speed data, pulse waves, heating the resolver with repeated high speed runs, and replacing components as countermeasures.
3. The diagram shows the speed detection process involving the resolver encoder and CPU.
1. The document provides troubleshooting steps for a detected speed error on TCD 169.
2. It first lists the point of detection and meaning, then provides 6 actions to take to resolve the issue, including checking wiring, voltage, speed data, pulse waves, heating the resolver with repeated high speed runs, and replacing components as countermeasures.
3. The diagram shows the speed detection process involving the resolver encoder and CPU.
1. The document provides troubleshooting steps for a detected speed error on TCD 169.
2. It first lists the point of detection and meaning, then provides 6 actions to take to resolve the issue, including checking wiring, voltage, speed data, pulse waves, heating the resolver with repeated high speed runs, and replacing components as countermeasures.
3. The diagram shows the speed detection process involving the resolver encoder and CPU.
When actual E/L speed exceeds 8m/min, and E/L filtered for 160msec is below speed of 0.3m/min.
1.Check R/E wiring.
1) Check 40T1 16 ~21 within control panel terminal for wiring [Diagram] status. 2) Check for any disconnection in terminal pressure section or JJH_Velocity>=8/60 CUR_V_0 connection status in the middle of wiring. TSPDFBT 0x3420 0x5700 2.Check P15V voltage. Check DC15V between pin 17 to 18 of 40T1.
3. Check speed data.
Check if detected speed values vary according to speed change. (Enter ‘A87E’ on ANN to check the speed detected by Run CPU and Speed CPU)
4.Check R/E output pulse wave form.
1) ØA Wave: 40T1/22~40T1/21 TSPDFBT 2) ØB Wave: 40T1/20~40T1/19 TCD169 Check for any pulse breakdown and, if any found, replace R/E. 0000H 5. R/E heating test(When the error is not reproduced) Repeating high-speed running, check the temperature increase status in main body and ØA,ØB wave form with oscilloscope.
6. Counter plan for unknown origin.
1) Replace R/E(It is necessary to separate SNAP RING.). 2) Replace and check DOC-200 and DPC-1XX PCB.