Point of ● Run CPU ● DI120-150

TCD 174/175 Present Floor Error / Precedent Floor Error Application


detection ○ Speed CPU ● DI180-420

[Meaning] If The current data value of present floor by rotary encoder is out [Action to take]
of range in floor height table, the present floor error will be
occurred. And if the distance for stop by slow down is out of range
in floor height table, the precedent floor error will be occurred.

[Explanation]
cur_enco < (floor_table[1]-PULSE_PER_METER/2)

cur_enco >
(floor_table[top_index]+PULSE_PER_METER/2)

ERR_NVRAM_FHT_SUM ERR_EEPROM_FHT_SUM

OR(DIGI_FL_CUR)
Err_Status->digital_fl

(Err_Status->digital_fl & DIGI_FL_CUR)


set_err(ERR_DIGI_FL_CUR)

UP_RUN cur_enco >


(Operation_Floor_Table[top_index]+PULSE_PER_METER/2)

DOWN_RU cur_enco < (Operation_Floor_Table[1]-PULSE_PER_METER/2)


N

AIS_SDS_FORCE_DEC_TESST OR(DIGI_FL_ADV)
Err_Status->digital_fl

(Err_Status->digital_fl & DIGI_FL_ADV)


set_err(ERR_DIGI_FL_ADV)
Point Of ● Run CPU ● DI120-150
TCD 184 Frequent compulsive SDS deceleration detection ○ Speed CPU
Application
● DI180-420

[Meaning] In case that the over-speed detected by slow down switch more than [Action to take]
3times due to bigger speed command value by normal speed pattern than
compulsive deceleration command value.
1. Check the error that is related speed control device
[Explanation] START 2. Check the SDS distance and its activated position.

NO
Running
YES NO
3. [attachment 3] refer to SDS standard distance table
NO SDS_FORCE_DEC_INIT
High speed mode && SDS operated 1) Compare the each SDS distance and SPEC
YES
YES NO
Sds_Force_Dec_Count<3 2) Check the each SDS speed standard SPEC data
Compulsive deceleration speed
pattern made. YES

Sds_Force_Dec_Count += 1
NO Current speed value >=
Compulsive deceleration speed value
YES

Compulsive deceleration by SDS


Over Speed
TCD 179
SDS_FORCE_DEC_INIT = ON

END
[SDS Activating Position]
Speed(m/min), Distance(mm) Application ●
Speed SDS NO Applied 7 6 5 4 3 2 1
Installation/Position Quantity 36,100 27,600 20,300 14,000 11,350 8,900 6,850 5,050 2,700 2,700 1,400 1,400 400
Allow able Error 700 500 400 200 150 100 70 70 50 50 20 20 5
480 7 ● ● ● ● ● ● ●
420 7 ● ● ● ● ● ● ●
360 6 ● ● ● ● ● ●
300 6 ● ● ● ● ● ●
270 5 ● ● ● ● ●
240 5 ● ● ● ● ●
210 4 ● ● ● ●
180 4 ● ● ● ●
150 3 ● ● ●
120 3 ● ● ●
105 2 ● ●
90 2 ● ●