Point of ● Run CPU ● DI120-150

TCD 168 Velocity Deviation Value Error ○ Speed CPU


Application
● DI180-420
Detection

[Meaning] When 30 m/min discrepancy lasts for 160 msec between speed command [Actions to take]
and detected speed during high-speed running.
1.Check speed detecting section.
1) Check to see if detected speed values vary according to
[Diagram]
speed change.
2) Enter ‘A87E’ on ANN to check the speed detected by
JJH_Velocity>=8/60 OS_C1BR FAST_RUN_COMMAND
Run CPU and Speed CPU.
3) Check GOV side and MOTOR side R/E pulse with
0x5590 0x5590
oscilloscope to see if there are any spherical wave found.

2. Verify if corrective actions are taken for NOISE.


Check what kind of actions have been taken for current
noise and if they have been done completely.
JJH_Velocity_Cvndl>Dir_REVERSE_V
TVSPDFT 1) Check from R/E to PCB to see if shield cables are used
0x3410
for them.
2) Check if R/E shield cables have been mounted with metal
duct.

TVSPDFT
TCD168
3. Check PCB.
0x3411 Replace and check DOC-200 & DPC-1XX PCB.