Point of ● Run CPU Application ● DI120-150

TCD 225 HALL SIDE ERROR


Detection ○ Speed CPU ● DI180-420

[Action to take]
[Meaning] Entire hall side error
1. Check the hall button power

2. Check communication line


[Explanation]
3. Check communication board
When all hall buttons in the specified hall side are failed, Check the flickering status along with each hall button column.
an error is defected and failed hall side is set with bit. If not flickering, check the slot insertion status of LON module
of each column. If LED 3~9 is flickering but LED11~LED17
connected to LED 3~9 respectively are not flickering, check
Variable ADDR Meaning communication.
HallLineDead 0x8740 1 ~ 8 line fault
0x8741 9 ~ 16line fault If both of LED pair(e.g. Column 1 is composed of LED3 and
0x8742 17 ~ 24line fault LED11) are not flickering but slots are well inserted, replace
the slots

4. Check hall board.

[Symptoms]

The hall call registering of specified area is impossible.