Sievert Emirates Inspection L.L.C.: Magnetic Particle Testing Report

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

CLIENT : Ener Mech UAE LLC

SIEVERT EMIRATES INSPECTION L.L.C.


P.O. Box: 54069, Abu Dhabi, UAE. CONTRACTOR : BUREAU VERITAS ABUDHABI
Tel: +971 2 5506781/82, Fax: +971 2 5506784,
Email: sievertuae@sievert.in, Website : www.sievert.in REPORT NO : SEIL-MPT-001
DATE : 19-01-2022 PAGE : 01 OF 01
MAGNETIC PARTICLE TESTING REPORT
ACCEPTANCE CRITERIA AWS D1.1 2020 Edn
MATERIAL TYPE CS
TECH YOKE METHOD
SEIL-TECH-SOP-AWS-MPT
Specification ASME SEC V & ASTEM E 709 Procedure No & rev No
Revision 2
METHOD /Technique Visibile , We t continues DC yoke Technique BEFORE/AFTER PWHT N/A

CONTRAST PAINT MAGNAFLUX WCP-2 (210816) EQUIPMENT TYPE MAGNETIC YOKE DC

MAGNETIC INK MAGNAFLUX 7 HF (210807) FIELD DIRECTION&SENSISTIVIY CHECK PIE GAUGE

SURFACE TEMPERATURE : AMBIENT MAGNETIC YOKE S/NO: K-08

Light Intensity: DAY LIGHT (>1076 lux) Field Adequacy: 3” to 6”

S.No Item Description Identification Number LOCATION RESULT REMARKS

LIFTING PAD WELD


1 N2 PUMP SKID ERAEM00030 JOINTS ( 4 NOS) ACC
Accessible Area
LIFTING PAD WELD
2 16 CYLINDER GAS RACK ERAEM00192 JOINTS ( 4 NOS) ACC
Accessible Area
LIFTING PAD WELD
3 185 CFM COMPRESSOR EM-400404 JOINTS ( 4 NOS) ACC
Accessible Area
LIFTING PAD WELD
4 10 FT CONTAINER ERAEM00935 JOINTS ( 4 NOS) ACC
Accessible Area

Note:
1. The inspection results relate exclusively to the work ordered or the object(s) or the lot inspected as above.
2. The inspection report shall not be reproduced except in full without the approval of the Sievert Emirates and its client

SIEVERT EMIRATES INSPECTION LLC CONTRACTOR COMPANY / TPI


Name: IKBAL ANSARI Name: Name:

ASNT LEVEL II

Signature: SIGN: SIGN:

Date: 19-01-2022 DATE: DATE:


SEIL-TECH-SRF-EIAC-MPT REV 0 02-01-2020

You might also like