CLIENT : ABU DHABI PORTS

SIEVERT EMIRATES INSPECTION LLC Contractor: Al Nasr Contracting


PO BOX: 54069, Abu Dhabi, UAE
Tel: +971 2 5506781/82, company LL.C
Fax: +971 2 5506784 PROJECT : Design and
Email: sievertabudhabi.ae@ae.bureauveritas.com
Website : www.sievert.in
Construction of KIZAD Gas
Project: Network –Phase 1

REPORT NO. : ANC-PL-PT-001


DATE OF
EXAMINATION
13/01/2022

LIQUID PENETRANT TESTING REPORT


PROJECT : Design and Construction of KIZAD Gas
Network –Phase 1 Any Major Report / Alteration Carried on the equipment: N/A
SITE: AL NASR OG 119 Kizad Site Office PRODUCTION NO. :2201-236
Procedure & Rev.:
2201-236-V8-7300-00195 Revision 0 Deviation / Additions / Exclusions of the Procedure if any:N/A
ANC-2201-236-STR-WPS-002

Material Type & Dimension: CS Examination Standard: ASTM – E – 709


Purpose of test : N/A SPECIFICATION: ASTM – E – 709 Edition

Test piece designation:N/A Acceptance Criteria:AWS D1.1 2020 Edition

Method/Technique: VISIBLE SOLVENT REMOVABLE Penetrant Dwell Time&Application:10-15 Min&Brushing


Penetrant Type (Visible/Fluorescent ):Visible Developing Time : 10 Min
Penetrant :SKL-SP2 Batch No: 210613 Surface condition:Smooth
Cleaner/Remover : SKC-S Batch No: 210808 Surface Temperature :Ambient
Developer : SKD-S2 Batch No: 210502 Lighting Intensity: <1076 Lux Lighting Eq: Day Light

DRAW NO. JOINT NO. WELDER DESCRIPTION RESULT OF TEST ACCEPT/REJECT


ID SEGMENT

3/4"-SGPL-KP01- _ FILLET WELD, NO RELEVANT ACCEPT


JOINT-1 VALVE PIT-1 INDICATION WELD AREA
FTJ25K

3/4"-BSGPL-KP01- _ FILLET WELD, NO RELEVANT ACCEPT


JOINT-2 VALVE PIT-2 INDICATION WELD AREA
FTJ64K

3/4"-BSGPL-KP00- FILLET WELD, NO RELEVANT


JOINT-3 _ VALVE PIT-3 INDICATION WELD AREA ACCEPT
FTJ66

NDT Sub Contractor


CONTRACTOR
Sievert Emirates Inspection LLC (ALNASR) PMC ABU DHABI PORTS
(SEIL)

Name : AVIJIT DEBNATH Name : Name : Name :

Signature : Signature : Signature : Signature :

Qualification:ASNT LEVELII Qualification: Qualification: Qualification:

Date :13.01.2022 Date : Date : Date :