Spacial
Metal enclosures and boxes
From our small boxes to large suitable floor-standing enclosures, with the Spacial
range you can find the perfect fit for your applications. Our extensive range of
easy-to-use accessories helps you save time during your projects.
Select between steel or stainless steel to better suit the installation environment.
In our stainless-steel offer you can find the optimal solution where cleanliness is
required, or for highly corrosive environments.
Thalassa
PB500006
Insulating enclosures
Working in difficult environments can, without the right protection, expose your
installation to chemical or aggressive substances. Developed to efficiently protect it;
our Thalassa offer, from boxes to floor-standing enclosures, made in fibreglass-
reinforced polyester, resists in hard conditions and outdoor applications.
Our Thalassa industrial boxes in ABS or polycarbonate are strong, easy to install and
designed to be used in highly demanding environments.
PB501325SE-20
PB501325-20
Consult us.
ClimaSys
Thermal management
PB502612-30
Preserving and keeping the right temperature inside your enclosure is vital for
maximising the lifetime of your installed devices. With our ClimaSys offer you can
find the right solution, be it Ventilation, Cooling or Heating, including control units
for temperature, humidity and much more.
3
Industry and Infrastructure Offer
A material for every environment
Steel
PB500013-55
PB500016-48
(ABS, polycarbonate)
Infrastructures and industrial environments
Outdoor infrastructures and electrical installations are exposed to direct sunlight,
rain, saline mist, extreme temperatures, oil splashes, chemical and corrosive agents.
bb Standard range, for industry and infrastructures.
bb Range of ATEX enclosures, for potentially explosive atmospheres.
> Solution:
The Thalassa range (boxes, wall-mounting and
floor-standing enclosures).
PB502733-26
4
Selection tools
www.schneider-electric.com
PB500009-165
Our web site allows you to access all the Schneider Electric products in just two
clicks with direct links to:
bb A complete library of technical documents, catalogues,
DB300835-15
FAQs brochures, etc.
bb Certificates.
bb 2D & 3D drawings.
bb Selection Guides from the e-catalogue.
bb Product discovery sites.
You may also find illustrated overviews, news to which you can subscribe, a list of
country contacts and more useful information.
Digital Rules
Find the accessories that suit
your enclosure
The digital rules allow you to select the best
components from the current product range.
There will be no risk of mistake, since product
and accessory selection take place automatically,
saving you time and money.
PB500011-38
ProClima
Find the best thermal solution
for your enclosure
Select and calculate your thermal management
requirements, according to the environment
and the electrical/electronic devices installed
inside the enclosure.
Spacial.conf New
DB300837-21
5
The customised solutions
Over 50 years of experience, knowledge and expertise to have the best
enclosure solution that meets your needs.
Configured: Specific:
the enriched standard the co-developed
offer offer
Feasibility automatically guaranteed by the Special dimensions, accessories and logistic
configurator software Spacial.conf, which gives needs. You participate to the whole development
you autonomy and flexibility to quickly define process of your "Tailor-made" solution.
your customized enclosure. According to co-developed specifications.
Committed delivery date.
Wall-mounting
Compact floor-standing
Modular floor-standing
6
Time saving Logistics Installation Ergonomic
simplified design
elivered with
D ●●Flexible management Enclosures delivered Customized project
cut-outs & painting: of your logistic option with cut-outs: you don’t dedicate to your
no waste of time (scheduled delivery need special tools personal concern
service for on-going
orders)
●●Special packaging
PB500518-182
7
Offers overview
Spacial enclosures
Steel Stainless-steel
SDB Derivation boxes and small enclosures p. 34
PB502487-14
PB500198-13
Characteristics
bb From 85 x 85 x 49 to 400 x 800 x 120 mm
bb IP55 or IP66
bb Up to IK10
PB500075-42
PB500066-84
New
Characteristics Characteristics
bb From 300 x 200 x 150 to 1400 x 1000 x 300 mm bb From 300 x 200 x 150 to 1400 x 1000 x 300 mm
bb Up to IP66 bb Up to IP66
bb Up to IK10 bb Up to IK10
p. 108 p. 160
PB500067-82
monobloc
SF Floor-standing suitable p. 109 SFX Floor-standing p. 160
Automobile application p. 394 suitable
SFHF Electromagnetic compatibility p. 343
SF 5G, SFP 5G Seismic and nuclear enclosures p. 320
New
Characteristics Characteristics
bb From 1200 x 600 x 300 to 2200 x 1600 x 800 mm bb From 1200 x 600 x 300 to 2200 x 1600 x 800 mm
bb IP55 bb IP66
bb Up to IK10 bb Up to IK10
Options
Ventilated plinths, roof ventilation module, slim fanbox,
Heavy Duty mountings. Consult us
Why should I choose it?
Designed to resist in outdoor private areas.
Characteristics
bb From 300 x 200 x 180 to 2000 x 800 x 630 mm
bb Up to IP66
bb IK10
PB501267-30
PB502000-32
PB502624-10
PB502618-9
New New
ClimaSys
management
PB500069-30
p. 406 p. 459
PB502047-10
8
Offers overview
Thalassa enclosures
Insulating materials
Details and technical
PLS Insulating modular boxes p. 184 datasheets available on
PB500090-16
PB500091-24
PB501290-52
TBP Polycarbonate industrial boxes p. 170 www.schneider-electric.com
TBS ABS industrial boxes p. 170
Characteristics
bb From 74 x 74 x 54 to 540 x 720 x 230 mm
bb Up to IP66, NEMA 4X
bb Up to IK09 softwares
PB501325-30
PB502083
Characteristics
bb From 308 x 215 x 160 to 1056 x 852 x 350 mm
bb Up to IP66, NEMA 4X
bb Up to IK10
Spacial.pro
Graphic
configurator
PB502084
PLA Floor-standing polyester enclosures p. 210
PB500078-64
Characteristics
bb From 500 x 500 x 320 to 1500 x 1250 x 420 mm Digital Rules
bb Up to IP65, NEMA 4 Enclosures selector
bb Up to IK10
New
PB502686-23
Spacial.conf
Thalassa PHD has multiple virtues:
Services
New bb pressure and shock resistant (IEC 61439-5),
bb anti-posting thanks to its special front door, configurator
bb insulated (Class II).
Options
PB500011-30
PB502663-17
PB500073-34
PB501866-28
PB500072-16
New
Mounting Power Cable
distribution management
Configured offer
PB501903-17
PB501971-24
PB501922-23
painting, assemblies…
Specific offer
The co-development service tailor-made for you Mounting
Cable gland plate Doors Door accessories hardware Roof accessories
9
10
Universal Enclosures Contents
Selection guide 12
Steel
New Steel industrial boxes 33
Stainless-steel
Stainless-steel wall-mounting enclosures 149
Insulating materials
Insulating boxes 169
Accessories 235
11
Spacial SDB and SBM Selection guide
Steel industrial boxes
12
Thalassa TBS - TBP - PLS Selection guide
Insulating industrial boxes
PB500090-16
PB500091-24
Overall external Overall internal Body Cover Material
dimensions (mm) dimensions (mm) (mm) (mm) ABS IP66 IK07 PC-UL IP66 IK08
Height Width Depth Height Width Depth Opaque cover Transparent cover Opaque cover Transparent cover
74 74 54 65 65 47 37 10 NSYTBS775 - NSYTBP775 -
89 89 54 80 80 47 37 10 NSYTBS885 - NSYTBP885 -
116 74 62 105 65 55 45 10 NSYTBS1176 - NSYTBP1176 -
94 105 65 85 45 40 NSYTBS1179H - - -
116 62 105 105 55 45 10 NSYTBS11116 - NSYTBP11116 -
133 105 105 125 45 80 NSYTBS111113H - - -
138 93 72 125 80 65 45 20 NSYTBS1397 NSYTBS1397T NSYTBP1397 NSYTBP1397T
164 121 87 150 105 80 60 20 NSYTBS16128 NSYTBS16128T NSYTBP16128 NSYTBP16128T
192 121 87 175 105 80 60 20 NSYTBS19128 NSYTBS19128T NSYTBP19128 NSYTBP19128T
105 175 105 100 60 40 NSYTBS191210H NSYTBS191210HT NSYTBP191210H NSYTBP191210HT
164 87 175 150 80 60 20 NSYTBS19168 NSYTBS19168T NSYTBP19168 NSYTBP19168T
105 175 150 100 60 40 NSYTBS191610H NSYTBS191610HT NSYTBP191610H NSYTBP191610HT
241 194 87 225 175 80 60 20 NSYTBS24198 NSYTBS24198T NSYTBP24198 NSYTBP24198T
107 225 175 100 80 20 NSYTBS241910 NSYTBS241910T NSYTBP241910 NSYTBP241910T
107 225 175 100 60 40 NSYTBS241910H NSYTBS241910HT NSYTBP241910H NSYTBP241910HT
127 225 175 120 80 40 NSYTBS241912H NSYTBS241912HT NSYTBP241912H NSYTBP241912HT
291 241 88 275 225 80 60 20 NSYTBS29248 NSYTBS29248T NSYTBP29248 NSYTBP29248T
128 275 225 120 100 20 NSYTBS292412 NSYTBS292412T NSYTBP292412 NSYTBP292412T
128 275 225 120 60 60 NSYTBS292412H NSYTBS292412HT NSYTBP292412H NSYTBP292412HT
168 275 225 160 100 60 NSYTBS292416H NSYTBS292416HT NSYTBP292416H NSYTBP292416HT
341 291 128 325 275 120 100 20 NSYTBS342912 NSYTBS342912T NSYTBP342912 NSYTBP342912T
168 325 275 160 100 60 NSYTBS342916H NSYTBS342916HT NSYTBP342916H NSYTBP342916HT
Modular boxes
PB500094-16
PB500092-16
PB500095-14
PB500095-14
PB500093-16
13
Spacial CRN - CRNG Selection guide
Steel wall-mounting enclosures
PB500109-15
PB500110-12
Specifications Spacial CRN - CRNG
Dimensions No. of IP Weight Plain door with Plain door without Glazed door without
doors (1) mounting plate mounting plate mounting plate
H W D
CRN Wall-mounting steel enclosures
200 200 150 1 66 2.5 - NSYCRN22150 (2) -
300 150 1 66 3.9 - NSYCRN23150 (2) -
250 200 150 1 66 3.2 NSYCRN252150P NSYCRN252150 -
300 250 150 1 66 4.2 NSYCRN325150P NSYCRN325150 NSYCRN325150T
200 1 66 4.9 NSYCRN325200P NSYCRN325200 NSYCRN325200T
300 150 1 66 5.0 NSYCRN33150P NSYCRN33150 NSYCRN33150T
200 1 66 6.0 NSYCRN33200P NSYCRN33200 NSYCRN33200T
400 200 1 66 6.4 - NSYCRN34200 NSYCRN34200T
450 150 1 66 6.7 - NSYCRN345150 (2) -
400 300 150 1 66 6.0 NSYCRN43150P NSYCRN43150 NSYCRN43150T
200 1 66 6.8 NSYCRN43200P NSYCRN43200 NSYCRN43200T
400 200 1 66 8.0 NSYCRN44200P NSYCRN44200 NSYCRN44200T
600 250 1 66 10.0 NSYCRN46250P NSYCRN46250 NSYCRN46250T
300 1 66 11.2 - NSYCRN46300 NSYCRN46300T
500 400 150 1 66 8.7 NSYCRN54150P NSYCRN54150 NSYCRN54150T
200 1 66 9.8 NSYCRN54200P NSYCRN54200 NSYCRN54200T
250 1 66 11.0 NSYCRN54250P NSYCRN54250 NSYCRN54250T
500 250 1 66 12.8 NSYCRN55250P NSYCRN55250 NSYCRN55250T
600 400 150 1 66 9.3 NSYCRN64150P NSYCRN64150 NSYCRN64150T
200 1 66 10.8 NSYCRN64200P NSYCRN64200 NSYCRN64200T
250 1 66 12.3 NSYCRN64250P NSYCRN64250 NSYCRN64250T
500 150 1 66 11.3 NSYCRN65150P NSYCRN65150 NSYCRN65150T
200 1 66 14.3 NSYCRN65200P NSYCRN65200 NSYCRN65200T
250 1 66 16.2 NSYCRN65250P NSYCRN65250 NSYCRN65250T
600 200 1 66 16.3 - NSYCRN66200 NSYCRN66200T
250 1 66 18.2 NSYCRN66250P NSYCRN66250 NSYCRN66250T
300 1 66 19.8 NSYCRN66300P NSYCRN66300 NSYCRN66300T
800 300 1 66 26.0 - NSYCRN68300 NSYCRN68300T
700 500 200 1 66 17.3 NSYCRN75200P NSYCRN75200 NSYCRN75200T
250 1 66 19.3 NSYCRN75250P NSYCRN75250 NSYCRN75250T
800 600 200 1 66 21.8 NSYCRN86200P NSYCRN86200 NSYCRN86200T
250 1 66 24.8 NSYCRN86250P NSYCRN86250 NSYCRN86250T
300 1 66 26.3 NSYCRN86300P NSYCRN86300 NSYCRN86300T
800 200 1 66 29.5 NSYCRN88200P NSYCRN88200 NSYCRN88200T
300 1 66 32.5 NSYCRN88300P NSYCRN88300 NSYCRN88300T
1000 600 250 1 66 28.4 NSYCRN106250P NSYCRN106250 NSYCRN106250T
300 1 66 30.6 NSYCRN106300P NSYCRN106300 NSYCRN106300T
800 250 1 66 34.5 NSYCRN108250P NSYCRN108250 NSYCRN108250T
300 1 66 37.4 NSYCRN108300P NSYCRN108300 NSYCRN108300T
CRNG Wall-mounting steel enclosures with three-point locking system
800 600 400 1 66 30.0 - NSYCRNG86400 NSYCRNG86400T
1000 300 2 55 40.0 - NSYCRNG810300D -
1200 300 2 55 46.0 - NSYCRNG812300D -
1000 600 400 1 66 36.0 - NSYCRNG106400 NSYCRNG106400T
800 400 1 66 43.0 - NSYCRNG108400 NSYCRNG108400T
1000 300 2 (3) 55 47.0 - NSYCRNG1010300D NSYCRNG1010300T
1200 300 2 55 55.0 - NSYCRNG1012300D -
400 2 55 60.0 - NSYCRNG1012400D -
1200 600 300 1 66 37.0 - NSYCRNG126300 NSYCRNG126300T
400 1 66 42.0 - NSYCRNG126400 NSYCRNG126400T
800 300 1 66 45.0 - NSYCRNG128300 NSYCRNG128300T
400 1 66 50.0 - NSYCRNG128400 NSYCRNG128400T
1000 300 2 55 56.0 - NSYCRNG1210300D -
400 2 55 61.0 - NSYCRNG1210400D -
1200 300 2 55 64.0 - NSYCRNG1212300D -
400 2 55 90.0 - NSYCRNG1212400D -
1400 1000 300 2 55 80.0 - NSYCRNG1410300D -
(1) Enclosure without mounting plate.
(2) Two cable gland plates, one on the top, one on the bottom.
(3) Except glazed door in single door.
14
Spacial CRN - CRNG Selection guide
Steel wall-mounting enclosures
PB500102-13
PB500103-10
PB500104-12
PB500111-19
PB500072-10
PB500100-10
PB500101-13
Mounting plate Accessories
Plain Silkscreened Microperforated Telequick Bakelite DIN rails chassis Step slides
NSYMM22 - - - - - -
NSYMM32 - NSYMF32 - NSYMB32 - -
NSYMM2520 - - - - - -
NSYMM3025 - - NSYMR3025 NSYMB3025 - -
NSYMM3025 - - NSYMR3025 NSYMB3025 - NSYSDCR200
NSYMM33 - NSYMF33 NSYMR33 NSYMB33 NSYMD33 -
NSYMM33 - NSYMF33 NSYMR33 NSYMB33 NSYMD33 NSYSDCR200
NSYMM43 NSYMS43 NSYMF43 NSYMR34 NSYMB43 - NSYSDCR200
NSYMM3045 - - - NSYMB43 - -
NSYMM43 NSYMS43 NSYMF43 NSYMR43 NSYMB43 NSYMD43 -
NSYMM43 NSYMS43 NSYMF43 NSYMR43 NSYMB43 NSYMD43 NSYSDCR200
NSYMM44 NSYMS44 NSYMF44 NSYMR44 - - NSYSDCR200
NSYMM64 NSYMS64 NSYMF64 NSYMR46 NSYMB64 - NSYSDCR250
NSYMM64 NSYMS64 NSYMF64 NSYMR46 NSYMB64 - NSYSDCR300
NSYMM54 NSYMS54 NSYMF54 NSYMR54 NSYMB54 NSYMD54 -
NSYMM54 NSYMS54 NSYMF54 NSYMR54 NSYMB54 NSYMD54 NSYSDCR200
NSYMM54 NSYMS54 NSYMF54 NSYMR54 NSYMB54 NSYMD54 NSYSDCR250
NSYMM55 NSYMS55 NSYMF55 NSYMR55 - - NSYSDCR250
NSYMM64 NSYMS64 NSYMF64 NSYMR64 NSYMB64 NSYMD64 -
NSYMM64 NSYMS64 NSYMF64 NSYMR64 NSYMB64 NSYMD64 NSYSDCR200
NSYMM64 NSYMS64 NSYMF64 NSYMR64 NSYMB64 NSYMD64 NSYSDCR250
NSYMM65 - NSYMF65 NSYMR65 NSYMB65 - -
NSYMM65 - NSYMF65 NSYMR65 NSYMB65 - NSYSDCR200
NSYMM65 - NSYMF65 NSYMR65 NSYMB65 - NSYSDCR250
NSYMM66 NSYMS66 NSYMF66 NSYMR66 - NSYMD66 NSYSDCR200
NSYMM66 NSYMS66 NSYMF66 NSYMR66 - NSYMD66 NSYSDCR250
NSYMM66 NSYMS66 NSYMF66 NSYMR66 - NSYMD66 NSYSDCR300
NSYMM86 NSYMS86 NSYMF86 NSYMR68 - - NSYSDCR300
NSYMM75 NSYMS75 NSYMF75 NSYMR75 NSYMB75 NSYMD75 NSYSDCR200
NSYMM75 NSYMS75 NSYMF75 NSYMR75 NSYMB75 NSYMD75 NSYSDCR250
NSYMM86 NSYMS86 NSYMF86 NSYMR86 NSYMB86 NSYMD86 NSYSDCR200
NSYMM86 NSYMS86 NSYMF86 NSYMR86 NSYMB86 NSYMD86 NSYSDCR250
NSYMM86 NSYMS86 NSYMF86 NSYMR86 NSYMB86 NSYMD86 NSYSDCR300
NSYMM88 - NSYMF88 NSYMR88 - - NSYSDCR200
NSYMM86 - NSYMF88 NSYMR88 - - NSYSDCR300
NSYMM106 - NSYMF106 NSYMR106 NSYMB106 - NSYSDCR250
NSYMM106 - NSYMF106 NSYMR106 NSYMB106 - NSYSDCR300
NSYMM108 - NSYMF108 NSYMR108 NSYMB108 NSYMD108 NSYSDCR250
NSYMM108 - NSYMF108 NSYMR108 NSYMB108 NSYMD108 NSYSDCR300
15
Spacial S3DC - S3X Selection guide
Wall-mounting enclosures
16
Spacial S3DC - S3X Selection guide
for applicative and customised solutions
wall-mounting enclosures
Grounding
Grounding lead
NSYEL166D8
160, sec.6²
Grounding lead
NSYEL3525D8
L350, sec.25²
Grounding strip
connection NSYECB1M153
points 87
2 grounding
NSYEDCOS
collector supports
2 grounding
collector rail sup- NSYEDCOC
ports
Locking system
Screwdriver insert
NSYAEDLSD
for Thalassa PLM
17
Spacial SM - SF Selection guide
Steel floor-standing enclosures
SM
PB500480-12
PB500119-14
PB500481-12
PB500125-18
PB500123-18
PB500124-18
PB500126-13
Characteristics Door Plinth
18
Spacial SM - SF Selection guide
Steel floor-standing enclosures
SM
PB500473-12
PB500475-12
PB500477-7
PB500482-10
PB500483-13
Characteristics Inner door Mounting Vertical uprights Off-centre 19" Centred 19"
plate swing rack swing rack
Dimensions (mm) No. of Standard Technical
doors
H W D
(A) (B) (C)
1200 800 300 1 - NSYMP128 - NSYTVR12 - -
1000 300 2 - NSYMP1210 - NSYTVR12 - -
1200 400 2 - NSYMP1212 - NSYTVR12 - -
1400 600 300 1 - NSYMP146 - NSYTVR14 - -
400 1 - NSYMP146 - NSYTVR14 - -
800 300 1 - NSYMP148 - NSYTVR14 NSYRSW27 NSYRSWC27
400 1 - NSYMP148 - NSYTVR14 NSYRSW27 NSYRSWC27
1000 400 2 - NSYMP1410 - NSYTVR14 - -
1200 400 2 - NSYMP1412 - NSYTVR14 - -
1600 600 300 1 NSYID166 NSYMP166 - NSYTVR16 - -
400 1 NSYID166 NSYMP166 - NSYTVR16 - -
800 300 1 NSYID168 NSYMP168 - NSYTVR16 NSYRSW31 NSYRSWC31
400 1 NSYID168 NSYMP168 - NSYTVR16 NSYRSW31 NSYRSWC31
1000 300 2 - NSYMP1610 - NSYTVR16 - -
400 2 - NSYMP1610 - NSYTVR16 - -
1200 300 2 - NSYMP1612 - NSYTVR16 - -
400 2 - NSYMP1612 - NSYTVR16 - -
1800 600 300 1 NSYID186 NSYMP186 NSYVR18 NSYTVR18 - -
400 1 NSYID186 NSYMP186 NSYVR18 NSYTVR18 - -
500 1 NSYID186 NSYMP186 NSYVR18 NSYTVR18 - -
800 300 1 NSYID188 NSYMP188 NSYVR18 NSYTVR18 NSYRSW36 NSYRSWC36
400 1 NSYID188 NSYMP188 NSYVR18 NSYTVR18 NSYRSW36 NSYRSWC36
500 1 NSYID188 NSYMP188 NSYVR18 NSYTVR18 NSYRSW36 NSYRSWC36
600 1 NSYID188 NSYMP188 NSYVR18 NSYTVR18 NSYRSW36 NSYRSWC36
1000 400 1 NSYID1810 NSYMP1810 NSYVR18 NSYTVR18 - -
400 2 NSYID1810 NSYMP1810 NSYVR18 NSYTVR18 - -
500 2 NSYID1810 NSYMP1810 NSYVR18 NSYTVR18 - -
1200 400 2 - NSYMP1812 NSYVR18 NSYTVR18 - -
500 2 - NSYMP1812 NSYVR18 NSYTVR18 - -
1600 400 2 - NSYMP1816 NSYVR18 NSYTVR18 - -
500 2 - NSYMP1816 NSYVR18 NSYTVR18 - -
2000 600 300 1 NSYID206 NSYMP206 NSYVR20 NSYTVR20 - -
400 1 NSYID206 NSYMP206 NSYVR20 NSYTVR20 - -
500 1 NSYID206 NSYMP206 NSYVR20 NSYTVR20 - -
800 300 1 NSYID208 NSYMP208 NSYVR20 NSYTVR20 NSYRSW40 NSYRSWC40
400 1 NSYID208 NSYMP208 NSYVR20 NSYTVR20 NSYRSW40 NSYRSWC40
500 1 NSYID208 NSYMP208 NSYVR20 NSYTVR20 NSYRSW40 NSYRSWC40
600 1 NSYID208 NSYMP208 NSYVR20 NSYTVR20 NSYRSW40 NSYRSWC40
1000 400 2 NSYID2010 NSYMP2010 NSYVR20 NSYTVR20 - -
500 2 NSYID2010 NSYMP2010 NSYVR20 NSYTVR20 - -
1200 400 2 - NSYMP2012 NSYVR20 NSYTVR20 - -
500 2 - NSYMP2012 NSYVR20 NSYTVR20 - -
600 2 - NSYMP2012 NSYVR20 NSYTVR20 - -
1600 400 2 - NSYMP2016 NSYVR20 NSYTVR20 - -
500 2 - NSYMP2016 NSYVR20 NSYTVR20 - -
600 2 - NSYMP2016 NSYVR20 NSYTVR20 - -
19
Spacial SM - SF Selection guide
Steel floor-standing enclosures
SF
PB500511-10
PB500112-15
PB500113-13
PB500114-7
PB500115-18
PB500116-18
PB500117-18
Nominal No. of Door Side Cable-entry plate
dimensions (mm) doors panels
Plain Transparent
Height Width Depth With mounting Without mounting Without Plain 1 entry 2 entries
(A) (B) (C) plate plate mounting plate
20
Spacial SM - SF Selection guide
Steel floor-standing enclosures
SF PB500123-18
PB500126-13
PB500477-7
PB500512-16
PB500482-10
PB500483-13
PB500124-18
PB500125-18
Nominal Plinth Mounting Intermediate Vertical uprights
dimensions (mm) plate mounting plate
Height 100 mm Height 200 mm Standard Technical
Height Width Depth Front kit Side panels, Front kit Side panels,
(A) (B) (C) (corners + 2 u. (corners + 4 u.
front panels) front panels)
1200 600 400 NSYSPF6100 NSYSPS4100 NSYSPF6200 NSYSPS4200 NSYMP126 NSYSIMP12 - NSYTVR12
600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP126 NSYSIMP12 - NSYTVR12
800 400 NSYSPF8100 NSYSPS4100 NSYSPF8200 NSYSPS4200 NSYMP128 NSYSIMP12 - NSYTVR12
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP128 NSYSIMP12 - NSYTVR12
1400 600 400 NSYSPF6100 NSYSPS4100 NSYSPF6200 NSYSPS4200 NSYMP146 NSYSIMP14 - NSYTVR14
800 400 NSYSPF8100 NSYSPS4100 NSYSPF8200 NSYSPS4200 NSYMP148 NSYSIMP14 - NSYTVR14
1600 600 600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP166 NSYSIMP16 - NSYTVR16
800 NSYSPF6100 NSYSPS8100 NSYSPF6200 NSYSPS8200 NSYMP166 NSYSIMP16 - NSYTVR16
800 600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP168 NSYSIMP16 - NSYTVR16
800 NSYSPF8100 NSYSPS8100 NSYSPF8200 NSYSPS8200 NSYMP168 NSYSIMP16 - NSYTVR16
1800 400 400 NSYSPF4100 NSYSPS4100 NSYSPF4200 NSYSPS4200 - - NSYVR18 NSYTVR18
500 NSYSPF4100 NSYSPS5100 NSYSPF4200 NSYSPS5200 - - NSYVR18 NSYTVR18
600 NSYSPF4100 NSYSPS6100 NSYSPF4200 NSYSPS6200 - - NSYVR18 NSYTVR18
600 400 NSYSPF6100 NSYSPS4100 NSYSPF6200 NSYSPS4200 NSYMP186 NSYSIMP18 NSYVR18 NSYTVR18
500 NSYSPF6100 NSYSPS5100 NSYSPF6200 NSYSPS5200 NSYMP186 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP186 NSYSIMP18 NSYVR18 NSYTVR18
800 NSYSPF6100 NSYSPS8100 NSYSPF6200 NSYSPS8200 NSYMP186 NSYSIMP18 NSYVR18 NSYTVR18
800 400 NSYSPF8100 NSYSPS4100 NSYSPF8200 NSYSPS4200 NSYMP188 NSYSIMP18 NSYVR18 NSYTVR18
500 NSYSPF8100 NSYSPS5100 NSYSPF8200 NSYSPS5200 NSYMP188 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP188 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP188 NSYSIMP18 NSYVR18 NSYTVR18
1000 400 NSYSPF10100 NSYSPS4100 NSYSPF10200 NSYSPS4200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
400 NSYSPF10100 NSYSPS4100 NSYSPF10200 NSYSPS4200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
500 NSYSPF10100 NSYSPS5100 NSYSPF10200 NSYSPS5200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
1200 400 NSYSPF12100 NSYSPS4100 NSYSPF12200 NSYSPS4200 NSYMP1812 NSYSIMP18 NSYVR18 NSYTVR18
500 NSYSPF12100 NSYSPS5100 NSYSPF12200 NSYSPS5200 NSYMP1812 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF12100 NSYSPS6100 NSYSPF12200 NSYSPS6200 NSYMP1812 NSYSIMP18 NSYVR18 NSYTVR18
2000 300 500 NSYSPF3100 NSYSPS5100 NSYSPF3200 NSYSPS5200 - - NSYVR20 NSYTVR20
600 NSYSPF3100 NSYSPS6100 NSYSPF3200 NSYSPS6200 - - NSYVR20 NSYTVR20
800 NSYSPF3100 NSYSPS8100 NSYSPF3200 NSYSPS8200 - - NSYVR20 NSYTVR20
400 400 NSYSPF4100 NSYSPS4100 NSYSPF4200 NSYSPS4200 - - NSYVR20 NSYTVR20
500 NSYSPF4100 NSYSPS5100 NSYSPF4200 NSYSPS5200 - - NSYVR20 NSYTVR20
600 NSYSPF4100 NSYSPS6100 NSYSPF4200 NSYSPS6200 - - NSYVR20 NSYTVR20
800 NSYSPF4100 NSYSPS8100 NSYSPF4200 NSYSPS8200 - - NSYVR20 NSYTVR20
600 400 NSYSPF6100 NSYSPS4100 NSYSPF6200 NSYSPS4200 NSYMP206 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF6100 NSYSPS5100 NSYSPF6200 NSYSPS5200 NSYMP206 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP206 NSYSIMP20 NSYVR20 NSYTVR20
800 NSYSPF6100 NSYSPS8100 NSYSPF6200 NSYSPS8200 NSYMP206 NSYSIMP20 NSYVR20 NSYTVR20
800 400 NSYSPF8100 NSYSPS4100 NSYSPF8200 NSYSPS4200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF8100 NSYSPS5100 NSYSPF8200 NSYSPS5200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
800 NSYSPF8100 NSYSPS8100 NSYSPF8200 NSYSPS8200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
1000 400 NSYSPF10100 NSYSPS4100 NSYSPF10200 NSYSPS4200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
400 NSYSPF10100 NSYSPS4100 NSYSPF10200 NSYSPS4200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF10100 NSYSPS5100 NSYSPF10200 NSYSPS5200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF10100 NSYSPS5100 NSYSPF10200 NSYSPS5200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
800 NSYSPF10100 NSYSPS8100 NSYSPF10200 NSYSPS8200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
1200 400 NSYSPF12100 NSYSPS4100 NSYSPF12200 NSYSPS4200 NSYMP2012 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF12100 NSYSPS5100 NSYSPF12200 NSYSPS5200 NSYMP2012 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF12100 NSYSPS6100 NSYSPF12200 NSYSPS6200 NSYMP2012 NSYSIMP20 NSYVR20 NSYTVR20
800 NSYSPF12100 NSYSPS8100 NSYSPF12200 NSYSPS8200 NSYMP2012 NSYSIMP20 NSYVR20 NSYTVR20
1600 400 NSYSPF16100 NSYSPS4100 NSYSPF16200 NSYSPS4200 NSYMP2016 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF16100 NSYSPS5100 NSYSPF16200 NSYSPS5200 NSYMP2016 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF16100 NSYSPS6100 NSYSPF16200 NSYSPS6200 NSYMP2016 NSYSIMP20 NSYVR20 NSYTVR20
2200 400 600 NSYSPF4100 NSYSPS6100 NSYSPF4200 NSYSPS6200 - - NSYVR22 NSYTVR22
600 600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP226 NSYSIMP22 NSYVR22 NSYTVR22
800 NSYSPF6100 NSYSPS8100 NSYSPF6200 NSYSPS8200 NSYMP226 NSYSIMP22 NSYVR22 NSYTVR22
800 600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP228 NSYSIMP22 NSYVR22 NSYTVR22
800 NSYSPF8100 NSYSPS8100 NSYSPF8200 NSYSPS8200 NSYMP228 NSYSIMP22 NSYVR22 NSYTVR22
1000 600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP2210 NSYSIMP22 NSYVR22 NSYTVR22
1200 600 NSYSPF12100 NSYSPS6100 NSYSPF12200 NSYSPS6200 NSYMP2212 NSYSIMP22 NSYVR22 NSYTVR22
800 NSYSPF12100 NSYSPS8100 NSYSPF12200 NSYSPS8200 NSYMP2212 NSYSIMP22 NSYVR22 NSYTVR22
21
Spacial SM - SF Selection guide
Steel floor-standing enclosures
PB500114-7
PB500130-7
PB500131-7
PB500477-7
PB500129-7
SF kit
PB500127-13
PB502078-17
PB500128-16
Nominal No. of Vertical Bottom Rear Side Plain door Transparent Door Trim Mounting
dimensions doors uprights frame panel panels (1) door plate plate
(mm) and top (Securit®
frame glass) (1)
with roof
Height Width Depth
(A) (B) (C)
1200 600 400 1 NSYSFV12 NSYSFC64 NSYBP126 NSY2SP124 NSYSFD126 NSYSFD126T NSYTRIM6SF NSYMP126
500 1 NSYSFV12 NSYSFC65 NSYBP126 NSY2SP125 NSYSFD126 NSYSFD126T NSYTRIM6SF NSYMP126
600 1 NSYSFV12 NSYSFC66 NSYBP126 NSY2SP126 NSYSFD126 NSYSFD126T NSYTRIM6SF NSYMP126
800 1 NSYSFV12 NSYSFC68 NSYBP126 NSY2SP128 NSYSFD126 NSYSFD126T NSYTRIM6SF NSYMP126
800 400 1 NSYSFV12 NSYSFC84 NSYBP128 NSY2SP124 NSYSFD128 NSYSFD128T NSYTRIM8SF NSYMP128
500 1 NSYSFV12 NSYSFC85 NSYBP128 NSY2SP125 NSYSFD128 NSYSFD128T NSYTRIM8SF NSYMP128
600 1 NSYSFV12 NSYSFC86 NSYBP128 NSY2SP126 NSYSFD128 NSYSFD128T NSYTRIM8SF NSYMP128
800 1 NSYSFV12 NSYSFC88 NSYBP128 NSY2SP128 NSYSFD128 NSYSFD128T NSYTRIM8SF NSYMP128
1400 600 400 1 NSYSFV14 NSYSFC64 NSYBP146 NSY2SP144 NSYSFD146 NSYSFD146T NSYTRIM6SF NSYMP146
500 1 NSYSFV14 NSYSFC65 NSYBP146 NSY2SP145 NSYSFD146 NSYSFD146T NSYTRIM6SF NSYMP146
600 1 NSYSFV14 NSYSFC66 NSYBP146 NSY2SP146 NSYSFD146 NSYSFD146T NSYTRIM6SF NSYMP146
800 1 NSYSFV14 NSYSFC68 NSYBP146 NSY2SP148 NSYSFD146 NSYSFD146T NSYTRIM6SF NSYMP146
800 400 1 NSYSFV14 NSYSFC84 NSYBP148 NSY2SP144 NSYSFD148 NSYSFD148T NSYTRIM8SF NSYMP148
500 1 NSYSFV14 NSYSFC85 NSYBP148 NSY2SP145 NSYSFD148 NSYSFD148T NSYTRIM8SF NSYMP148
600 1 NSYSFV14 NSYSFC86 NSYBP148 NSY2SP146 NSYSFD148 NSYSFD148T NSYTRIM8SF NSYMP148
800 1 NSYSFV14 NSYSFC88 NSYBP148 NSY2SP148 NSYSFD148 NSYSFD148T NSYTRIM8SF NSYMP148
1600 600 400 1 NSYSFV16 NSYSFC64 NSYBP166 NSY2SP164 NSYSFD166 NSYSFD166T NSYTRIM6SF NSYMP166
500 1 NSYSFV16 NSYSFC65 NSYBP166 NSY2SP165 NSYSFD166 NSYSFD166T NSYTRIM6SF NSYMP166
600 1 NSYSFV16 NSYSFC66 NSYBP166 NSY2SP166 NSYSFD166 NSYSFD166T NSYTRIM6SF NSYMP166
800 1 NSYSFV16 NSYSFC68 NSYBP166 NSY2SP168 NSYSFD166 NSYSFD166T NSYTRIM6SF NSYMP166
800 400 1 NSYSFV16 NSYSFC84 NSYBP168 NSY2SP164 NSYSFD168 NSYSFD168T NSYTRIM8SF NSYMP168
500 1 NSYSFV16 NSYSFC85 NSYBP168 NSY2SP165 NSYSFD168 NSYSFD168T NSYTRIM8SF NSYMP168
600 1 NSYSFV16 NSYSFC86 NSYBP168 NSY2SP166 NSYSFD168 NSYSFD168T NSYTRIM8SF NSYMP168
800 1 NSYSFV16 NSYSFC88 NSYBP168 NSY2SP168 NSYSFD168 NSYSFD168T NSYTRIM8SF NSYMP168
1800 400 400 1 NSYSFV18 NSYSFC44 NSYBP184 NSY2SP184 NSYSFD184 - NSYTRIM4SF -
500 1 NSYSFV18 NSYSFC45 NSYBP184 NSY2SP185 NSYSFD184 - NSYTRIM4SF -
600 1 NSYSFV18 NSYSFC46 NSYBP184 NSY2SP186 NSYSFD184 - NSYTRIM4SF -
800 1 NSYSFV18 NSYSFC48 NSYBP184 NSY2SP188 NSYSFD184 - NSYTRIM4SF -
600 400 1 NSYSFV18 NSYSFC64 NSYBP186 NSY2SP184 NSYSFD186 NSYSFD186T NSYTRIM6SF NSYMP186
500 1 NSYSFV18 NSYSFC65 NSYBP186 NSY2SP185 NSYSFD186 NSYSFD186T NSYTRIM6SF NSYMP186
600 1 NSYSFV18 NSYSFC66 NSYBP186 NSY2SP186 NSYSFD186 NSYSFD186T NSYTRIM6SF NSYMP186
800 1 NSYSFV18 NSYSFC68 NSYBP186 NSY2SP188 NSYSFD186 NSYSFD186T NSYTRIM6SF NSYMP186
800 400 1 NSYSFV18 NSYSFC84 NSYBP188 NSY2SP184 NSYSFD188 NSYSFD188T NSYTRIM8SF NSYMP188
500 1 NSYSFV18 NSYSFC85 NSYBP188 NSY2SP185 NSYSFD188 NSYSFD188T NSYTRIM8SF NSYMP188
600 1 NSYSFV18 NSYSFC86 NSYBP188 NSY2SP186 NSYSFD188 NSYSFD188T NSYTRIM8SF NSYMP188
600 2 NSYSFV18 NSYSFC86 NSYBP188 NSY2SP186 NSYSFD1882D - NSYTRIM8SF2D NSYMP188
800 1 NSYSFV18 NSYSFC88 NSYBP188 NSY2SP188 NSYSFD188 NSYSFD188T NSYTRIM8SF NSYMP188
800 2 NSYSFV18 NSYSFC88 NSYBP188 NSY2SP188 NSYSFD1882D - NSYTRIM8SF2D NSYMP188
1000 400 1 NSYSFV18 NSYSFC104 NSYBP1810 NSY2SP184 NSYSFD1810 NSYSFD1810T NSYTRIM10SF NSYMP1810
400 2 NSYSFV18 NSYSFC104 NSYBP1810 NSY2SP184 NSYSFD18102D - NSYTRIM10SF2D NSYMP1810
500 1 NSYSFV18 NSYSFC105 NSYBP1810 NSY2SP185 NSYSFD1810 NSYSFD1810T NSYTRIM10SF NSYMP1810
600 1 NSYSFV18 NSYSFC106 NSYBP1810 NSY2SP186 NSYSFD1810 NSYSFD1810T NSYTRIM10SF NSYMP1810
600 2 NSYSFV18 NSYSFC106 NSYBP1810 NSY2SP186 NSYSFD18102D - NSYTRIM10SF2D NSYMP1810
800 1 NSYSFV18 NSYSFC108 NSYBP1810 NSY2SP188 NSYSFD1810 NSYSFD1810T NSYTRIM10SF NSYMP1810
800 2 NSYSFV18 NSYSFC108 NSYBP1810 NSY2SP188 NSYSFD18102D - NSYTRIM10SF2D NSYMP1810
1200 400 2 NSYSFV18 NSYSFC124 NSYBP1812 NSY2SP184 NSYSFD18122D NSYSFD18122DT NSYTRIM12SF2D NSYMP1812
500 2 NSYSFV18 NSYSFC125 NSYBP1812 NSY2SP185 NSYSFD18122D NSYSFD18122DT NSYTRIM12SF2D NSYMP1812
600 2 NSYSFV18 NSYSFC126 NSYBP1812 NSY2SP186 NSYSFD18122D NSYSFD18122DT NSYTRIM12SF2D NSYMP1812
800 2 NSYSFV18 NSYSFC128 NSYBP1812 NSY2SP188 NSYSFD18122D NSYSFD18122DT NSYTRIM12SF2D NSYMP1812
(1) Hinges, locking bar catches and handle with 5-mm double-bar insert included.
22
Spacial SM - SF Selection guide
Steel floor-standing enclosures
PB500114-7
PB500130-7
PB500131-7
PB500477-7
PB500129-7
SF kit
PB500127-13
PB502078-17
PB500128-16
Nominal No. of Vertical Bottom Rear Side Plain door Transparent Door Trim Mounting
dimensions doors uprights frame panel panels (1) door plate plate
(mm) and top (Securit®
frame glass) (1)
with roof
Height Width Depth
(A) (B) (C)
2000 300 500 1 NSYSFV20 NSYSFC35 NSYBP203 NSY2SP205 NSYSFD203 - NSYTRIM3SF -
600 1 NSYSFV20 NSYSFC36 NSYBP203 NSY2SP206 NSYSFD203 - NSYTRIM3SF -
400 400 1 NSYSFV20 NSYSFC44 NSYBP204 NSY2SP204 NSYSFD204 - NSYTRIM4SF -
500 1 NSYSFV20 NSYSFC45 NSYBP204 NSY2SP205 NSYSFD204 - NSYTRIM4SF -
600 1 NSYSFV20 NSYSFC46 NSYBP204 NSY2SP206 NSYSFD204 - NSYTRIM4SF -
800 1 NSYSFV20 NSYSFC48 NSYBP204 NSY2SP208 NSYSFD204 - NSYTRIM4SF -
600 400 1 NSYSFV20 NSYSFC64 NSYBP206 NSY2SP204 NSYSFD206 NSYSFD206T NSYTRIM6SF NSYMP206
500 1 NSYSFV20 NSYSFC65 NSYBP206 NSY2SP205 NSYSFD206 NSYSFD206T NSYTRIM6SF NSYMP206
600 1 NSYSFV20 NSYSFC66 NSYBP206 NSY2SP206 NSYSFD206 NSYSFD206T NSYTRIM6SF NSYMP206
800 1 NSYSFV20 NSYSFC68 NSYBP206 NSY2SP208 NSYSFD206 NSYSFD206T NSYTRIM6SF NSYMP206
800 400 1 NSYSFV20 NSYSFC84 NSYBP208 NSY2SP204 NSYSFD208 NSYSFD208T NSYTRIM8SF NSYMP208
500 1 NSYSFV20 NSYSFC85 NSYBP208 NSY2SP205 NSYSFD208 NSYSFD208T NSYTRIM8SF NSYMP208
600 1 NSYSFV20 NSYSFC86 NSYBP208 NSY2SP206 NSYSFD208 NSYSFD208T NSYTRIM8SF NSYMP208
600 2 NSYSFV20 NSYSFC86 NSYBP208 NSY2SP206 NSYSFD2082D - NSYTRIM8SF2D NSYMP208
800 1 NSYSFV20 NSYSFC88 NSYBP208 NSY2SP208 NSYSFD208 NSYSFD208T NSYTRIM8SF NSYMP208
800 2 NSYSFV20 NSYSFC88 NSYBP208 NSY2SP208 NSYSFD2082D - NSYTRIM8SF2D NSYMP208
1000 400 1 NSYSFV20 NSYSFC104 NSYBP2010 NSY2SP204 NSYSFD2010 NSYSFD2010T NSYTRIM10SF NSYMP2010
400 2 NSYSFV20 NSYSFC104 NSYBP2010 NSY2SP204 NSYSFD20102D - NSYTRIM10SF2D NSYMP2010
500 1 NSYSFV20 NSYSFC105 NSYBP2010 NSY2SP205 NSYSFD2010 NSYSFD2010T NSYTRIM10SF NSYMP2010
500 2 NSYSFV20 NSYSFC105 NSYBP2010 NSY2SP205 NSYSFD20102D - NSYTRIM10SF2D NSYMP2010
600 1 NSYSFV20 NSYSFC106 NSYBP2010 NSY2SP206 NSYSFD2010 NSYSFD2010T NSYTRIM10SF NSYMP2010
600 2 NSYSFV20 NSYSFC106 NSYBP2010 NSY2SP206 NSYSFD20102D - NSYTRIM10SF2D NSYMP2010
800 1 NSYSFV20 NSYSFC108 NSYBP2010 NSY2SP208 NSYSFD2010 NSYSFD2010T NSYTRIM10SF NSYMP2010
800 2 NSYSFV20 NSYSFC108 NSYBP2010 NSY2SP208 NSYSFD20102D - NSYTRIM10SF2D NSYMP2010
1200 400 2 NSYSFV20 NSYSFC124 NSYBP2012 NSY2SP204 NSYSFD20122D NSYSFD20122DT NSYTRIM12SF2D NSYMP2012
500 2 NSYSFV20 NSYSFC125 NSYBP2012 NSY2SP205 NSYSFD20122D NSYSFD20122DT NSYTRIM12SF2D NSYMP2012
600 2 NSYSFV20 NSYSFC126 NSYBP2012 NSY2SP206 NSYSFD20122D NSYSFD20122DT NSYTRIM12SF2D NSYMP2012
800 2 NSYSFV20 NSYSFC128 NSYBP2012 NSY2SP208 NSYSFD20122D NSYSFD20122DT NSYTRIM12SF2D NSYMP2012
1600 400 2 NSYSFV20 NSYSFC164 NSYBP2016 NSY2SP204 NSYSFD20162D - NSYTRIM16SF2D NSYMP2016
500 2 NSYSFV20 NSYSFC165 NSYBP2016 NSY2SP205 NSYSFD20162D - NSYTRIM16SF2D NSYMP2016
600 2 NSYSFV20 NSYSFC166 NSYBP2016 NSY2SP206 NSYSFD20162D - NSYTRIM16SF2D NSYMP2016
2200 400 400 1 NSYSFV22 NSYSFC44 NSYBP224 NSY2SP224 NSYSFD224 - NSYTRIM4SF -
500 1 NSYSFV22 NSYSFC45 NSYBP224 NSY2SP225 NSYSFD224 - NSYTRIM4SF -
600 1 NSYSFV22 NSYSFC46 NSYBP224 NSY2SP226 NSYSFD224 - NSYTRIM4SF -
800 1 NSYSFV22 NSYSFC48 NSYBP224 NSY2SP228 NSYSFD224 - NSYTRIM4SF -
600 400 1 NSYSFV22 NSYSFC64 NSYBP226 NSY2SP224 NSYSFD226 NSYSFD226T NSYTRIM6SF NSYMP226
500 1 NSYSFV22 NSYSFC65 NSYBP226 NSY2SP225 NSYSFD226 NSYSFD226T NSYTRIM6SF NSYMP226
600 1 NSYSFV22 NSYSFC66 NSYBP226 NSY2SP226 NSYSFD226 NSYSFD226T NSYTRIM6SF NSYMP226
800 1 NSYSFV22 NSYSFC68 NSYBP226 NSY2SP228 NSYSFD226 NSYSFD226T NSYTRIM6SF NSYMP226
800 400 1 NSYSFV22 NSYSFC84 NSYBP228 NSY2SP224 NSYSFD228 NSYSFD228T NSYTRIM8SF NSYMP228
500 1 NSYSFV22 NSYSFC85 NSYBP228 NSY2SP225 NSYSFD228 NSYSFD228T NSYTRIM8SF NSYMP228
600 1 NSYSFV22 NSYSFC86 NSYBP228 NSY2SP226 NSYSFD228 NSYSFD228T NSYTRIM8SF NSYMP228
800 1 NSYSFV22 NSYSFC88 NSYBP228 NSY2SP228 NSYSFD228 NSYSFD228T NSYTRIM8SF NSYMP228
1000 400 1 NSYSFV22 NSYSFC104 NSYBP2210 NSY2SP224 NSYSFD2210 NSYSFD2210T NSYTRIM10SF NSYMP2210
500 1 NSYSFV22 NSYSFC105 NSYBP2210 NSY2SP225 NSYSFD2210 NSYSFD2210T NSYTRIM10SF NSYMP2210
600 1 NSYSFV22 NSYSFC106 NSYBP2210 NSY2SP226 NSYSFD2210 NSYSFD2210T NSYTRIM10SF NSYMP2210
800 1 NSYSFV22 NSYSFC108 NSYBP2210 NSY2SP228 NSYSFD2210 NSYSFD2210T NSYTRIM10SF NSYMP2210
1200 400 2 NSYSFV22 NSYSFC124 NSYBP2212 NSY2SP224 NSYSFD22122D NSYSFD22122DT NSYTRIM12SF2D NSYMP2212
500 2 NSYSFV22 NSYSFC125 NSYBP2212 NSY2SP225 NSYSFD22122D NSYSFD22122DT NSYTRIM12SF2D NSYMP2212
600 2 NSYSFV22 NSYSFC126 NSYBP2212 NSY2SP226 NSYSFD22122D NSYSFD22122DT NSYTRIM12SF2D NSYMP2212
800 2 NSYSFV22 NSYSFC128 NSYBP2212 NSY2SP228 NSYSFD22122D NSYSFD22122DT NSYTRIM12SF2D NSYMP2212
(1) Hinges, locking bar catches and handle with 5-mm double-bar insert included.
23
Spacial S3X - S3XEX Selection guide
Stainless-steel wall-mounting enclosures
PB500075-30
PB500133-21
PB500134-23
PB500072-15
PB500135-27
Dimensions (mm) No. of No. of 304L stainless-steel 316L 304L Plain
locks doors stainless-steel stainless-steel mounting
canopy plate***
Height Width Depth Plain door Glazed door** Plain door
300 200 150 1 1 NSYS3X3215 - NSYS3X3215H NSYTX2015 NSYMM32
250 150 1 1 NSYS3X302515 - NSYS3X302515H NSYTX2515 NSYMM3025
300 150 1 1 NSYS3X3315 - NSYS3X3315H NSYTX3015 NSYMM33
400 300 150 1 1 NSYS3X4315 - NSYS3X4315H NSYTX3015 NSYMM43
200 1 1 NSYS3X4320 NSYS3X4320T NSYS3X4320H NSYTX3020 NSYMM43
400 200 1 1 NSYS3X4420 - NSYS3X4420H NSYTX4020 NSYMM44
600 200 1 1 NSYS3X4620 - NSYS3X4620H NSYTX6020 NSYMM64
500 400 200 2 1 NSYS3X5420 NSYS3X5420T NSYS3X5420H NSYTX4020 NSYMM54
600 400 200 2 1 NSYS3X6420 NSYS3X6420T NSYS3X6420H NSYTX4020 NSYMM64
600 250 2 1 NSYS3X6625 - NSYS3X6625H NSYTX6025 NSYMM66
1000 300 1 2 NSYS3X601030 - - - -
1200 300 1 2 NSYS3X601230 - - NSYTX12030 -
700 500 250 2 1 NSYS3X7525 NSYS3X7525T NSYS3X7525H NSYTX5025 NSYMM75
800 600 250 2 1 NSYS3X8625 NSYS3X8625T NSYS3X8625H NSYTX6025 NSYMM86
800 300 2 1 NSYS3X8830 - NSYS3X8830H NSYTX8030 NSYMM88
1000 300 1 2 NSYS3X801030 - - - -
1200 300 1 2 NSYS3X801230 - - NSYTX12030 -
1000 800 300 2 1 NSYS3X10830 NSYS3X10830T NSYS3X10830H NSYTX8030 NSYMM108
1000 300 * 2 NSYS3X101030 - NSYS3X101030H NSYTX10030 NSYMM1010
1200 800 300 2 1 NSYS3X12830 - NSYS3X12830H NSYTX8030 NSYMM128
1000 300 * 2 NSYS3X121030 - NSYS3X121030H NSYTX10030 NSYMM1210
* Three-point closure system.
** The glazed door has no reinforcement.
*** See other mounting plates in common accessoires.
Selection guide for wall-mounting enclosures
and main accessories
PB500100-15
PB500072-15
PB500101-20
PB500102-20
PB500075-27
PB500104-19
PB500136-20
Dimensions (mm) Enclosure Mounting plate reference DIN rail Step slides
chassis
Height Width Depth References Plain Silkscreened Microperforated Telequick
300 200 150 NSYS3XEX3215 NSYMM32 - NSYMF32 NSYMR32 - -
400 300 200 NSYS3XEX4320 NSYMM43 NSYMS43 NSYMF43 NSYMR43 NSYMD43 NSYSDCR200
500 400 200 NSYS3XEX5420 NSYMM54 NSYMS54 NSYMF54 NSYMR54 NSYMD54 NSYSDCR200
600 400 200 NSYS3XEX6420 NSYMM64 NSYMS64 NSYMF64 NSYMR64 NSYMD64 NSYSDCR200
700 500 250 NSYS3XEX7525 NSYMM75 NSYMS75 NSYMF75 NSYMR75 NSYMD75 NSYSDCR250
800 600 250 NSYS3XEX8625 NSYMM86 NSYMS86 NSYMF86 NSYMR86 NSYMD86 NSYSDCR250
1000 800 300 NSYS3XEX10830 NSYMM108 - NSYMF108 NSYMR108 NSYMD108 NSYSDCR300
24
Spacial SMX - SFX - SDX Selection guide
Stainless-steel floor-standing enclosures
PB500122-9
PB502483-28
PB502485-26
Plinth height 100 mm Plinth height 100 mm
(4 corners + front and back) (Set of 2 side panels)
Dimensions (mm) Number Stainless-steel Brushed 304L / 316L* Brushed 304L / 316L* Plain
of front floor-standing stainless-steel plinth height stainless-steel plinth height mounting
doors enclosure 100 mm** 200 mm** plate***
304L / 316L*
Height Width Depth Kit (4 corners + Set of Kit (4 corners + Set of 2 side
front and back) 2 side panels front and back) panels (x2)
1400 1000 300 2 NSYSMX141030 NSYSPFX10100 NSYSPSX3100 NSYSPFX10200 NSYSPSX3200 NSYMP1410
1600 800 400 1 NSYSMX16840 NSYSPFX8100 NSYSPSX4100 NSYSPFX8200 NSYSPSX4200 NSYMP168
1800 600 400 1 NSYSMX18640 - NSYSPSX4100 - NSYSPSX4200 NSYMP186
800 400 1 NSYSMX18840* NSYSPFX8100 NSYSPSX4100 NSYSPFX8200 NSYSPSX4200 NSYMP188
1200 400 2 NSYSMX181240* NSYSPFX12100 NSYSPSX4100 NSYSPFX12200 NSYSPSX4200 NSYMP1812
1600 400 2 NSYSMX181640* NSYSPFX16100 NSYSPSX4100 NSYSPFX16200 NSYSPSX4200 NSYMP1816
2000 800 500 1 NSYSMX20850 NSYSPFX8100 NSYSPSX5100 NSYSPFX8200 NSYSPSX5200 NSYMP208
1000 400 2 NSYSMX201040* NSYSPFX10100 NSYSPSX4100 NSYSPFX10200 NSYSPSX4200 NSYMP2010
1200 500 2 NSYSMX201250* NSYSPFX12100 NSYSPSX5100 NSYSPFX12200 NSYSPSX5200 NSYMP2012
1600 600 2 NSYSMX201660* NSYSPFX16100 NSYSPSX6100 NSYSPFX16200 NSYSPSX6200 NSYMP2016
* For version in AISI 316L stainless steel, add the lettre H to the end of the reference. Example NSYSMX18840H.
** See section on stainless-steel composition accessories. - *** See other mounting plates in common accessories.
PB502483-28
PB502485-26
PB500122-9
PB500143-33
PB502591-18
PB500072-15
PB502589-30
Plinth height 100 mm (Front and rear) Plinth height 100 mm (Side panels)
Dimensions (mm) References Number 316L stainless-steel plinth, 316L stainless-steel plinth, Plain
of front height 100 mm (1) height 200 mm (1) mounting
doors plate (2)
Height Width Depth Front and rear side panels Front and rear side panels
1000 600 500 NSYSDX6 1 NSYSPFX6100H NSYSPSX5100H NSYSPFX6200H 2 x NSYSPSX5100H NSYPMP8560
800 500 NSYSDX8 1 NSYSPFX8100H NSYSPSX5100H NSYSPFX8200H 2 x NSYSPSX5100H NSYPMP8580
1000 500 NSYSDX10 2 NSYSPFX10100H NSYSPSX5100H NSYSPFX10200H 2 x NSYSPSX5100H NSYPMP85100
1200 500 NSYSDX12 2 NSYSPFX12100H NSYSPSX5100H NSYSPFX12200H 2 x NSYSPSX5100H NSYPMP85120
(1) See section on stainless-steel composition accessories. - (2) See other mounting plates in common accessories.
25
Thalassa PLM - PLMEX Selection guide
Polyester wall-mounting enclosures
PB500144-28
PB500147-18
PB500146-17
PB501264-17
PB501265-17
Dimensions (mm) ABS/PC wall-mounting Polyester wall-mounting enclosures IP66
enclosures IP66
Height Width Depth Plain door Transp. door Plain door Transp. door Plain door Transp. door
3-point closure 3-point closure
PB500149-34
PB500150-36
PB500102-16
PB500101-15
PB500100-11
PB500072-11
PB500148-23
26
Thalassa PLM - PLMEX Selection guide
Polyester wall-mounting enclosures
Mounting accessories
PB500102-16
PB500103-11
PB500151-16
PB500152-29
PB500153-12
PB500154-11
PB500072-11
PB500100-11
PB500101-15
Dimensions (mm) Metallic mounting plates Insulating mounting Modular Step Symmetrical
plates distribution slides DIN rail
chassis
Height Width Depth Plain Silkscreened Microperforated Telequick Bakelite Polyester
Main accessories
PB500159-18
PB500158-34
PB500155-14
PB501746-13
PB500157-13
PB500156-27
PB500161-15
PB500160-15
Dimensions (mm) Mounting Post- Floor- Coupling Cable- Internal Blanking Plinth ZM
brackets mounting mounting frame gland door plates RAL 7032
device pillar plate
Height Width Depth
310 215 160 NSYPFPLM32 - - - - - NSYCEPLMA -
308 255 160 NSYPFPLM - - - - NSYPA3025PLM - -
430 330 200 NSYPFPLM NSYSFP300 - - - NSYPAP43 NSYCEPLMB -
530 430 200 NSYPFPLM NSYSFP400 NSYSFSPLM - - NSYPAP54 NSYCEPLMB -
647 436 250 NSYPFPLM NSYSFP400 NSYSFSPLM - - NSYPAP64 NSYCEPLMC -
747 536 300 NSYPFPLM NSYSFP500 - NSYBUPLM NSYTLA4420 NSYPAP75 NSYCEPLMC NSYZM253
847 636 300 NSYPFPLM NSYSFP600 - NSYBUPLM NSYTLA4420 NSYPAP86 NSYCEPLMC NSYZM263
1056 852 350 NSYPFPLM - - NSYBU108PLM NSYTLA6420 NSYPAP108 - NSYZM283
PB500163-29
PB500164-22
27
Thalassa PLA - PLAZ Selection guide
Polyester floor-standing enclosures
PB502899-21
PB502897-22
PB502898-23
Dimensions (mm) Completely sealed enclosures, IP65 Enclosures with plinth-type
open bottom part, IP54
References of enclosures with door
Height (A) Width (B) Depth (C) N° of doors Plain Glazed Plain
500 500 320 1 NSYPLA553 NSYPLA553T NSYPLAZ553
420 1 NSYPLA554 NSYPLA554T NSYPLAZ554
750 320 1 NSYPLA573 NSYPLA573T NSYPLAZ573
420 1 NSYPLA574 NSYPLA574T NSYPLAZ574
1000 320 2 NSYPLA5103 NSYPLA5103T NSYPLAZ5103
420 2 NSYPLA5104 NSYPLA5104T NSYPLAZ5104
1250 320 2 NSYPLA5123 NSYPLA5123T NSYPLAZ5123
420 2 NSYPLA5124 NSYPLA5124T NSYPLAZ5124
750 500 320 1 NSYPLA753 NSYPLA753T NSYPLAZ753
420 1 NSYPLA754 NSYPLA754T NSYPLAZ754
750 320 1 NSYPLA773 NSYPLA773T NSYPLAZ773
420 1 NSYPLA774 NSYPLA774T NSYPLAZ774
1000 320 2 NSYPLA7103 NSYPLA7103T NSYPLAZ7103
420 2 NSYPLA7104 NSYPLA7104T NSYPLAZ7104
1250 320 2 NSYPLA7123 NSYPLA7123T NSYPLAZ7123
420 2 NSYPLA7124 NSYPLA7124T NSYPLAZ7124
1000 500 320 1 NSYPLA1053 NSYPLA1053T NSYPLAZ1053
420 1 NSYPLA1054 NSYPLA1054T NSYPLAZ1054
750 320 1 NSYPLA1073 NSYPLA1073T NSYPLAZ1073
420 1 NSYPLA1074 NSYPLA1074T NSYPLAZ1074
1000 320 2 NSYPLA10103 NSYPLA10103T NSYPLAZ10103
420 2 NSYPLA10104 NSYPLA10104T NSYPLAZ10104
1250 320 2 NSYPLA10123 NSYPLA10123T NSYPLAZ10123
420 2 NSYPLA10124 NSYPLA10124T NSYPLAZ10124
1250 500 320 1 NSYPLA1253 NSYPLA1253T NSYPLAZ1253
420 1 NSYPLA1254 NSYPLA1254T NSYPLAZ1254
750 320 1 NSYPLA1273 NSYPLA1273T NSYPLAZ1273
420 1 NSYPLA1274 NSYPLA1274T NSYPLAZ1274
1000 320 2 NSYPLA12103 NSYPLA12103T NSYPLAZ12103
420 2 NSYPLA12104 NSYPLA12104T NSYPLAZ12104
1250 320 2 NSYPLA12123 NSYPLA12123T NSYPLAZ12123
420 2 NSYPLA12124 NSYPLA12124T NSYPLAZ12124
1500 500 320 1 NSYPLA1553 NSYPLA1553T NSYPLAZ1553
420 1 NSYPLA1554 NSYPLA1554T NSYPLAZ1554
750 320 1 NSYPLA1573 NSYPLA1573T NSYPLAZ1573
420 1 NSYPLA1574 NSYPLA1574T NSYPLAZ1574
1000 320 2 NSYPLA15103 NSYPLA15103T NSYPLAZ15103
420 2 NSYPLA15104 NSYPLA15104T NSYPLAZ15104
1250 320 2 NSYPLA15123 NSYPLA15123T NSYPLAZ15123
420 2 NSYPLA15124 NSYPLA15124T NSYPLAZ15124
28
Thalassa PLAT - PLAZT Selection guide
Polyester floor-standing enclosures
PB502900-21
PB502901-19
Dimensions (mm) Enclosures with ventilated Enclosures with plinth-type
canopy, IP44 open bottom part and ventilated
canopy, IP44
References of enclosures with door
Height (A) Width (B) Depth (C) N° of doors Plain Plain
500 500 320 1 NSYPLAT553 NSYPLAZT553
420 1 NSYPLAT554 NSYPLAZT554
750 320 1 NSYPLAT573 NSYPLAZT573
420 1 NSYPLAT574 NSYPLAZT574
1000 320 2 NSYPLAT5103 NSYPLAZT5103
420 2 NSYPLAT5104 NSYPLAZT5104
1250 320 2 NSYPLAT5123 NSYPLAZT5123
420 2 NSYPLAT5124 NSYPLAZT5124
750 500 320 1 NSYPLAT753 NSYPLAZT753
420 1 NSYPLAT754 NSYPLAZT754
750 320 1 NSYPLAT773 NSYPLAZT773
420 1 NSYPLAT774 NSYPLAZT774
1000 320 2 NSYPLAT7103 NSYPLAZT7103
420 2 NSYPLAT7104 NSYPLAZT7104
1250 320 2 NSYPLAT7123 NSYPLAZT7123
420 2 NSYPLAT7124 NSYPLAZT7124
1000 500 320 1 NSYPLAT1053 NSYPLAZT1053
420 1 NSYPLAT1054 NSYPLAZT1054
750 320 1 NSYPLAT1073 NSYPLAZT1073
420 1 NSYPLAT1074 NSYPLAZT1074
1000 320 2 NSYPLAT10103 NSYPLAZT10103
420 2 NSYPLAT10104 NSYPLAZT10104
1250 320 2 NSYPLAT10123 NSYPLAZT10123
420 2 NSYPLAT10124 NSYPLAZT10124
1250 500 320 1 NSYPLAT1253 NSYPLAZT1253
420 1 NSYPLAT1254 NSYPLAZT1254
750 320 1 NSYPLAT1273 NSYPLAZT1273
420 1 NSYPLAT1274 NSYPLAZT1274
1000 320 2 NSYPLAT12103 NSYPLAZT12103
420 2 NSYPLAT12104 NSYPLAZT12104
1250 320 2 NSYPLAT12123 NSYPLAZT12123
420 2 NSYPLAT12124 NSYPLAZT12124
1500 500 320 1 NSYPLAT1553 NSYPLAZT1553
420 1 NSYPLAT1554 NSYPLAZT1554
750 320 1 NSYPLAT1573 NSYPLAZT1573
420 1 NSYPLAT1574 NSYPLAZT1574
1000 320 2 NSYPLAT15103 NSYPLAZT15103
420 2 NSYPLAT15104 NSYPLAZT15104
1250 320 2 NSYPLAT15123 NSYPLAZT15123
420 2 NSYPLAT15124 NSYPLAZT15124
29
Thalassa PLA Selection guide
Polyester floor-standing enclosures
Mounting accessories
PB500102-23
PB500175-18
PB500102-21
PB500072-16
PB500151-22
PB500103-15
Dimensions (mm) Metallic mounting Insulating mounting Modular distribution Internal door
plates plates chassis
Height Width N° of Plain Telequick Polyester Bakelite
doors
PB500177-40
PB502913-18
PB502927-18
30
Thalassa PLA Selection guide
Polyester floor-standing enclosures
Composition accessories
PB500181-16
DB300012-16
PB501736-16
PB500180-16
PB500183-16
PB501735-16
PB501734-16
PB500182-17
Dimensions N plinth H plinth ZA plinth ZZ plinth Floor-fixing Canopy Cable-entry
(mm) frame plate
Width Depth Height 60 mm Height 900 mm Height 200 mm Height 200 mm Height 500 mm
500 320 NSYZNPLA53 NSYZHPLA53 NSYZA253 NSYZZ253 NSYZZ553 NSYMFPLAZ53 NSYTJPLA53 NSYECPLAZ53
420 NSYZNPLA54 NSYZHPLA54 NSYZA273 NSYZZ273 NSYZZ573 NSYMFPLAZ54 NSYTJPLA54 NSYECPLAZ54
750 320 NSYZNPLA73 NSYZHPLA73 NSYZA2103 NSYZZ2103 NSYZZ5103 NSYMFPLAZ73 NSYTJPLA73 NSYECPLAZ73
420 NSYZNPLA74 NSYZHPLA74 NSYZA2123 NSYZZ2123 NSYZZ5123 NSYMFPLAZ74 NSYTJPLA74 NSYECPLAZ74
1000 320 NSYZNPLA103 NSYZHPLA103 NSYZA254 NSYZZ254 NSYZZ554 NSYMFPLAZ103 NSYTJPLA103 NSYECPLAZ103
420 NSYZNPLA104 NSYZHPLA104 NSYZA274 NSYZZ274 NSYZZ574 NSYMFPLAZ104 NSYTJPLA104 NSYECPLAZ104
1250 320 NSYZNPLA123 NSYZHPLA123 NSYZA2104 NSYZZ2104 NSYZZ5104 NSYMFPLAZ123 NSYTJPLA123 NSYECPLAZ123
420 NSYZNPLA124 NSYZHPLA124 NSYZA2124 NSYZZ2124 NSYZZ5124 NSYMFPLAZ124 NSYTJPLA124 NSYECPLAZ124
PB500187-22
PB500188-23
PB500189-18
PB500190-23
PB500191-15
PB500192-10
PB500193-11
PB500194-21
31
Steel
industrial boxes
32
Universal Enclosures Steel industrial boxes
Contents
PB500198-13
Spacial SDB 34
Metallic junction boxes and small metallic enclosures
Characteristics 34
36
PB502069-20
New
Spacial SBM
Steel industrial boxes
Introduction 36
Characteristics 37
Technical characteristics 38
Dimensions 39
Specific accessories overview 40
Common accessories overview 41
Mounting accessories 42
Mounting accessories 44
33
Spacial SDB Metallic junction boxes
Characteristics
PB500198-36
PB500237-38
Characteristics Metallic junction boxes
bb PVC sealing gasket on sizes up to 20/15 and a rubber gasket for > 25/20.
bb Back ready for threaded drill holes for mounting equipment. From size 15/10 and up, there
are four M4 threaded holes fitted with removable plugs for direct mounting of the mounting plate.
bb The SDB series consists of 4 basic models:
vv without knock-outs: with high cover, vv without knock-outs: with low cover,
vv with knock-outs: NSYDApppM with vv with knock-outs: NSYDBpppM with
high cover. low cover.
Material Sheet steel
Finish Protected inside and outside with textured epoxy-polyester paint
Colour RAL 7035 grey
Ingress protection rating IP55 according to IEC 60529
Mechanical protection rating IK07
Installation Indoor installation:
direct wall-mounting by means of drill holes fitted with plastic plugs to ensure sealing
Outdoor installation:
compliant with IEC 62208 regarding type tests specified in §9.12 (resistance to ultra-violet (UV)
radiation) and §9.13 (resistance to corrosion). It is always advisable to install a canopy to avoid
water stagnation on the upper part of the enclosure
References
NSYDANppp NSYDBNppp
Dimensions
Models External dimensions Models Models with knock-outs, Dimensions Plain Weight
(mm) without no. of drill holes, knock-outs (mm) mounting (kg)
knock-outs and group plate
Height (A) Width (B) Depth (C) References References Height (A) Width (B) D E F References
Low cover 85 85 49 NSYDBN88 NSYDB88M 1 n° 1 1 n° 1 58 58 - - 0.18
105 105 49 NSYDBN1010 NSYDB1010M 2 n° 1 1 n° 1 76 76 - - 0.25
155 105 61 NSYDBN1510 NSYDB1510M 3 n° 1 1 n° 2 124 74 56 NSYPMD1510 0.38
206 156 83 NSYDBN2015 NSYDB2015M 3 n° 3 2 n° 3 172 122 78 NSYPMD2015 1
256 206 93 NSYDBN2520 NSYDB2520M 3 n° 4 2 n° 4 220 170 88 NSYPMD2520 1.5
307 257 116 NSYDBN3025 NSYDB3025M 2 n° 3, 2 n° 4 3 n° 4 268 218 110 NSYPMD3025 3.3
357 307 136 NSYDBN3530 NSYDB3530M 2 n° 3, 3 n° 4 2 n° 3, 2 n° 4 318 268 130 NSYPMD3530 4.8
High cover 155 105 88 NSYDAN1510 NSYDA1510M 3 n° 2 1 n° 2 124 74 83 NSYPMD1510 0.45
206 156 122 NSYDAN2015 NSYDA2015M 3 n° 3 2 n° 3 172 122 121 NSYPMD2015 1.2
256 206 140 NSYDAN2520 NSYDA2520M 3 n° 4 2 n° 4 220 170 131 NSYPMD2520 1.9
DB300021EN
DB300022EN
DB300023EN
DB300024EN
34
Spacial SDB Small metallic enclosures
PB500236-35
Characteristics
PB500238-32
Small metallic enclosures
bb Enclosures fitted with sealing gasket and M4 threaded holes fitted with removable plugs for mounting the mounting plate and/or equipment in general.
bb Lock with double-bar insert operated with key (standard supply ). Mounting this key to the insert will convert it into a handle lock.
See other lock possibilities in the insert table.
bb The Spacial SDB series with hinges consists of 2 models:
vv low cover. vv high cover.
Sheet steel
Protected inside and outside with textured epoxy-polyester paint
RAL 7035 grey
IP55 according to IEC 60529
-
NSYDANpppD NSYSDBNpppD
Dimensions
Models External dimensions (mm) Models without Dimensions (mm) Plain Weight
knock-outs mounting (kg)
plate
Height (A) Width (B) Depth (C) References D E F G References
Low cover 206 156 83 NSYDBN2015D 172 122 78 55 NSYPMD2015 1
256 206 93 NSYDBN2520D 220 170 88 55 NSYPMD2520 1.5
307 257 116 NSYDBN3025D 268 218 110 55 NSYPMD3025 3.3
357 307 136 NSYDBN3530D 318 268 130 55 NSYPMD3530 4.8
High cover 206 156 122 NSYDAN2015D 172 122 121 45 NSYPMD2015 1.2
256 206 140 NSYDAN2520D 220 170 131 45 NSYPMD2520 1.9
307 257 174 NSYDAN3025D 268 218 168 45 NSYPMD3025 4
357 307 210 NSYDAN3530D 318 268 204 45 NSYPMD3530 5.8
DB300026EN-110
vv 6 mm LC-7 NSYTC6CRN
DB300027-9
NSYDBN...D NSYDAN...D
35
Spacial SBM Steel industrial boxes
Introduction
Selection
PB502112-17
New bb 3 versions: flat box (SBM), FL21 entry box (SBMC)
and bus box (SBMB).
bb 80 mm and 120 mm depth.
Simplicity, ergonomics and bb FL21 cable entries available according to the version.
versatility, it's all in the box.
PB502109-60
Modularity
PB502113-30
bb 28 sizes available.
bb Up to 42 sizes possible thanks to the optional
Extension box accessory.
Ergonomics
PB502073-20
Easy installation
DB300080
See page 396 for details or consult our web site www.schneider-electric.com
36
Spacial SBM Steel industrial boxes
Characteristics
New PB502069-40
PB502070-35
PB502071-35
Spacial SBM Spacial SBMC Spacial SBMB
Flat box FL21 Entry box Bus box
Box with plain faces. Equipped with two or more FL21 cable Equipped with FL 21 cable gland plates,
gland plates. a hinged cover with a transparent
polycarbonate window and a DIN rail.
Box body
Single-piece body (rectangular structure). Front design incorporating folded gutters. Flat rear.
2 (or 3*) drilled profiles for installing mounting plates and DIN rails, with mounting centres of 12.5 mm.
2 or more FL21 cable gland plates (1) for easy drilling and to guarantee the maximum access area, delivered with the enclosure.
Box cover
Equipped with 2, 3, 4 or 6 half-turn thread screws, according to the version (2) to ensure maximum watertightness.
Bus boxes equipped with cover hinges for a comfortable 180° door opening.
Polyurethane sealing gasket.
Protection of personnel
Earth connection mandatory for all boxes: Spacial SBM steel boxes are equipped with a M6 x 16 earth stud welded in the cover,
to be linked with the body for equipotential connection. Earth braid to be ordered separately (Ø 6.4 mm terminal).
Material Sheet steel
Finish Structured
Colour RAL 7035 grey
Ingress protection rating IP66 IP55
Mechanical protection IK10 IK08
rating
Standard Compliance with enclosure standard IEC 62208 and the RoHS directive
Certifications bb UL, BV, DNV, LR, GL bb UL, BV, DNV, LR, GL
bb Type 4, 4X according to UL 508A bb Type 12, 12K according to UL 508A standard
standard bb Fire class: M0
bb Fire class: M0
Installation Indoor installation
Direct wall-mounting (4 x Ø 10 mm holes with sealing plugs to maintain the IP rating) or with the help of mounting brackets installed from
the outside (to be ordered separately, see the specific accessory pages).
Distance between mounting holes enables the installation of the box in the same locations as many existing enclosures.
Marks on the rear of the box locate the mounting points of obsolete Schneider Electric models.
Marks on the sides help with drilling the body to install hinges
Outdoor installation
Compliant with IEC 62208 regarding type tests specified in §9.12 (resistance to ultra-violet (UV) radiation) and §9.13 (resistance
to corrosion). It is always advisable to place the box under shelter to avoid water stagnation on the upper part of the enclosure
Maximum load Loading capacity on the body: 50 kg/m²
Other characteristics Vibration constraints
Specific construction of the Spacial SBM - Single-piece body (rectangular structure). The rear is flat without added parts - this ensures
compliance with certain vibration constraints. The tests were conducted according to the marine application by "Det Norske Veritas".
Boxes labelled "DNV" have undergone these tests and obtained classification "A"
* 3 profiles for width 800 mm.
(1) Only on Entry boxes and Bus boxes.
(2) 2 for Bus box (3 screws for width greater than 400 mm), 4 for Flat and Entry boxes (6 screws for width greater than 400 mm).
37
Spacial SBM Steel industrial boxes
Technical characteristics
216 Ø 9.5
DB300807EN
38
Spacial SBM Steel industrial boxes
Dimensions
Section A-A
DB300808EN
G
H H
C
D
E
Section B-B
Ah Bw
Bh Ah
F
39
Spacial SBM Steel industrial boxes
Specific accessories overview
Mounting accessories
Extension box Mounting plate DIN rail
PB502111-29
PB502100-29
PB502101-29
Page 42 Page 43 Page 43
PB502097-29
Page 43 Page 43
Mounting accessories
Mounting brackets Self-tapping screws Hinges
PB502098-10
PB502104-8
PB502102-17
PB502106-7
PB502103-18
40
Spacial SBM Steel industrial boxes
Common accessories overview
Cable management
Cable entries
PB502439-30
Page 270
41
Spacial SBM Steel industrial boxes
Mounting accessories
PB502069-20
PB502070-20
PB502071-20
PB502111-20
New
Characteristics Flat box FL21 entry box Bus box Extension box (2)
Extension box that fits
onto the corresponding
box of the same height
and width:
bb improved ergonomics
and accessibility inside
the box,
bb increases the interior
depth of the box
(+80 mm).
Material Sheet steel
Colour RAL 7035
Ingress protection rating IP66 (1 extension)
Installation Two earth braids must be
used with the extension
box
42
Spacial SBM Steel industrial boxes
PB502100-20
Mounting accessories
PB502097-20
PB502099-16
PB502101-20
1 unit, supplied without screws 10 rails, supplied without screws 1 unit 1 gasket and necessary hardware
43
Spacial SBM Steel industrial boxes
Mounting accessories
PB502069-20
PB502070-20
PB502071-20
New
Colour
Ingress protection rating
Installation
Maximum load
44
Spacial SBM Steel industrial boxes
Mounting accessories
PB502103-13
PB502098-7
PB502105-7
PB502106-5
PB502102-12
PB502104-6
45
Steel
wall-mounting
enclosures
46
Universal Enclosures Steel wall-mounting enclosures
Contents
Spacial S3DC 48
PB500199-22
Steel wall-mounting enclosures
Introduction 48
Characteristics 56
Protection 58
Dimensions 59
Selection Guide 60
Accessories 62
Cable Management 76
Disconnect Enclosures 78
Spacial CRN-CRNG 84
PB500369-31
47
Spacial S3D - S3X Wall-mounting enclosures
Introduction
Steel enclosures
Mounting
& cabling systems
for setting up devices
and managing cabling
Thermal
management
for controlling the internal
temperature & humidity of
the enclosure
3
Time-saving & easy to equip
Material
Solutions ...with direct installation of the mounting plate.
Polyester
48
Spacial S3D - S3X Simple to choose,
simple to order
and simple to use!
Spacial S3X Thalassa™ PLM
Spacial S3X is commonly used in: Thalassa PLM offers excellent performance in:
> Food & beverage and pharmaceutical
> Outdoor applications, such as road & train
industries, where the ability to clean hard water is
infrastructures, airports and harbors, including
required to help prevent the growth of bacteria.
saline environments.
> The oil & gas industries, for its chemical
> A good choice for harsh environments where
resistance.
non-corrosive materials are required.
49
Spacial S3DC - S3X Wall-mounting enclosures
Selection guide
50
Spacial S3DC - S3X Wall-mounting enclosures
Selection guide
Grounding
Grounding lead
NSYEL166D8
160, sec. 6²
Grounding lead
NSYEL3525D8
L350, sec. 25²
Grounding strip
connection NSYECB1M153
points 87
2 grounding
NSYEDCOS
collector supports
2 grounding
collector rail sup- NSYEDCOC
ports
Locking system
Screwdriver insert
NSYAEDLSD
for Thalassa PLM
51
Spacial S3DC Steel wall-mounting enclosures
Selection guide
S3DCD
S3HF
*
52
Spacial S3DC Steel wall-mounting enclosures
Selection guide
Automation
Network and
Electronics
*
Spacial S3DC:
The multipurpose
enclosure
53
Spacial S3DC Steel wall-mounting enclosures
Features
Useful life
Quality of the welding Component
and the coating. security
●W ater and dust
tightness and impact
Easy handling resistance.
● EMC and ATEX offer.
●R eusable, eco-friendly
packaging.
● No sharp corners.
Increased
choice
●L arge range of
standard sizes.
● Application offer with
special sizes.
Easy
installation
●F our 10-mm (0.4 in)
shouldered welded
studs.
● Broad range of
mounting plates.
● Wire guides welded
to the door on
enclosures 400 mm
(15.7 in.) or higher.
Easy
Added value maintenance
to your work ●R
emovable hinges.
●Q
uality and ●1
lock command on
aesthetics. enclosures 600 mm
(23.6 in.) or higher.
54
Spacial S3DC Steel wall-mounting enclosures
Accessories
3
4
1
7
5
8
6
2
1 Wall-mounting 5 Installation
55
Spacial S3DC Steel wall-mounting enclosures
Characteristics
Technical characteristics
Enclosure body
●S ingle-piece body (cross-shaped structure). Gutter-shaped front profile with
3-point lock enclosure. One action point enclosure. double fold. Flat rear.
● 4 (or 6**) M8 25 shouldered backstuds for installing mounting plates and step
slides, leaving a space of 10 mm (0.4 in.) behind them.
● M6 16 grounding studs for equipotential connection between the door and the
body of the enclosure.
● Four direct wall-mounting drill holes [ 10 mm (0.4 in.)] are sealed with plugs to
maintain the degree of protection. Or mount with lugs installed from the outside
(lugs ordered separately, see page 66).
Enclosure door
●W all-mounting enclosure supplied with screwdriver insert lock as standard.
● Polyurethane door gasket.
● M6 3 16 grounding studs for equipotential connection between the door and the
body of the enclosure.
● Easily removable and reversible, with 20-mm (0.8 in.) return with double thickness
Welded studs for the ground for excellent rigidity, opening to 120°, equipped with 2 or 3 invisible hinges*.
connection. ● For heights from 600 mm (23.6 in.), three locking points with linkage, with a single
control point. Simple reversal of linkage. Maximum load: 50 kg/m2.
● Perforated rails on the door, with pre-drilled holes with a diameter of 4.2 mm
(0.2 in.) in steps of 25 mm (1.0 in.):
– 2 vertical rails from the height of 400 mm (15.7 in.),
– 2 vertical rails and 2 horizontal rails from the width of 800 mm (31.5 in.).
Standards
Compliance with enclosure standards IEC 62208, UL 508A. Environmental testing
to UL 50E.
Screwdriver lock The Spacial S3DC wall-mounting enclosures are compliant with the RoHS directive.
(coin protected).
Certifications
For certification table, see page 478.
56
Delivered in a reusable
cardboard box with
assembly instructions
enclosed and wall-
mounting template on
the cardboard.
*
Our certificates can be
downloaded from our
website.
Spacial S3DC Steel wall-mounting enclosures
Characteristics
Our empty enclosures are marked CE according to the Low-Voltage Directive (LVD).
It is the responsibility of the final equipment manufacturer to respect the regulations
in force.
Technical characteristics
Protection degree
● IP66 for the single-door enclosures and IP55 for the double-door enclosures,
according to IEC 60529.
● UL/NEMA rated 4, 4X for the single-door enclosures and 12, 12K, 13 for the
double-door enclosures according to UL 50E and NEMA 250.
Mechanical characteristics
Attachment of mounting hardware
●4 (or 6**) M8 3 25 shouldered backstuds for installing mounting plates and step
slides, leaving a space of 10 mm (0.4 in.) behind them.
** 6 studs for widths 1000 and 1200 mm (39.4 and 47.2 in.).
Personnel protection
Ground connection: Spacial S3DC steel enclosures are equipped with M6 3
16 grounding studs welded in the body and the door for equipotential connection.
Grounding braid ordered separately (see page 303).
Closing the enclosure: enclosures of 600 mm (23.6 in.) and higher are equipped
with three linked locking points, with a single control point, preventing the
enclosures from being left ajar. For locks and inserts see page 72.
Coating properties
Color: RAL 7035 gray; finish: structured.
Coating thickness: 60 μm.
Fire class: M0.
Resistance to corrosion: compliance with standard IEC 62208 for outdoor
installation: 288 h of humid heat and 336 h of salt mist.
Note: the Spacial S3DC is specially designed for indoor installations. For outdoor
installations, it is advisable to install a canopy or contact us.
Protection from nuclear contamination (NFT 30901): RAL 7035 and AFNOR
A550 tests available on request.
*
For further
information, see the
technical annexes on
page 478.
57
Spacial S3DC Steel wall-mounting enclosures
Protection
EMC protection
Standard Spacial S3DC enclosures are tested against electromagnetic disruptions.
Since the enclosure is tested empty, it is advisable to rerun the tests with the
enclosure equipped in its final configuration.
90
80
70
60
50
40
30
20
10
0
0,1 1 10 100 1000
Frequency (MHz)
Magnetic field
Electrical field
Vibration constraints
The Spacial S3DC enclosure is constructed as a single-piece body with a cross-
shaped structure. The rear is flat without added parts, allowing it to comply with
specific vibration constraints.
Frequency: 3 - 13.2 Hz
Amplitude: 1 mm/sec below 22 Hz The tests were conducted according to the "rules for ships" by "Det Norske Veritas."
Frequency: 3 - 100 Hz Enclosures labelled "DNV" have undergone these tests and obtained classification "A."
Acceleration: 0.7 g above 30 Hz Since the enclosure is tested empty, it is advisable to rerun the tests with the
enclosure equipped in its final configuration.
ATEX compliance
The Spacial S3DC enclosure (with adaptation) is certified ATEX by the LCIE.
Environmental consideration
Compliance with RoHS standard.
58
Spacial S3DC Steel wall-mounting enclosures
Dimensions
A: Enclosure height
B: Enclosure width
1-door enclosure
C: Enclosure depth
(2)
(2)
(2)
(3) (3)
(4) (4)
A-75 (A-3.0) (3)
A-45 (A-1.8) (4)
(A-3.0)
(A-1.8)
(A-3.0)
(A-1.8)
A-75A-75
A-45A-45
A A
(1) 4
or 6 M8 3 25 mm (1.0 in.) backstuds with widths
A
1000 to 1200 mm (39.4 to 47.2 in.).
(2) 2 M6 3 17.5 mm (0.7 in.) grounding studs.
*
(3) Stud center-to-center distance. Ø10
(4) Center-to-center distance of the holes for direct mounting. Ø10
(2) Ø10
(2)
(2) B-75 (B-3.0) (3) (1) C-23
B-45B-75 (B-3.0) (3) C-23
(1) (C-0.9)
B-75 (B-1.8)
(B-3.0) (4)
(3) (1) C-23
B-45 (B-1.8) (4) C(C-0.9)
(C-0.9)
B-45 (B-1.8) (4) C
B C (2)
23 (0.9)
B 23 (0.9) (2)
B 23 (0.9) (2)
30 (1.2) (1)
30 (1.2) (1)
(C-1.9)
(C-1.1)
C-48C-48
30 (1.2) (1)
C-28C-28
(C-1.9)
(C-1.1)
C-48
105 (4.1)
(C-1.9)
(2) (2)
C-28
The DXF diagrams can (C-1.1)
105 (4.1)
(2) (2)
105 (4.1)
(2) (2)
be downloaded from our
35 (1.4)
35 (1.4)
B-42 (B-1.7)
website. 35 (1.4)
B-42 (B-1.7)
B-42 (B-1.7)
Detail (1) Detail (2)
D
E
*
C
F
(2)
Areas without cut-outs, 4.2 (0.2) (1)
see page 65. (1) Perforations in steps of 25 mm (1.0 in.).
(2) 1 M6 3 17.5 mm (0.7 in.) grounding stud.
59
Spacial S3DC Steel wall-mounting enclosures
Selection guide
Installation accessories
Description Catalog number
Set of 4 steel mounting lugs NSYAEFPFSC
60
Spacial S3DC Steel wall-mounting enclosures
Selection guide
61
Spacial S3DC Steel wall-mounting enclosures
Accessories
Thermal
For closing management
Page 72 Page 408
For cable
management
Page 290
62
Spacial S3DC Steel wall-mounting enclosures
Coupling accessories
Coupling frame
● Allows lateral coupling of 2 enclosures.
● The frame is made of polyester charged with self-extinguishing fiberglass.
● A built-in sealing gasket helps ensure the IP66 degree of protection.
● Mounting by screws, included.
● Dimensions: 435 3 185 mm (17.1 3 7.3 in.) and 635 3 185 mm (25.0 3 7.3 in.).
Installation example. ● These frames allow the door to open to 120º.
ø6
11
(0.4)
Version with cable entry.
14
9
(5.
9)
.5
19 8) 25
(0. (1.
0)
63
Spacial S3DC Accessories
Telequick mounting plates
Catalog number
NSYEMR
*
Advantages of Telequick
mounting solution
●N o more drawing on the mounting plate.
● No more machining of the mounting plate.
64
Spacial S3DC Accessories
Telequick mounting plates
B: Enclosure width
C: Enclosure depth
Right
Porte Grounding stud
C 7.5
P A-3
C-23 (C-0.9) 1 .7)
50 (2.0)
70 M6 (0
P-23 (2.8)
10
120 (4.7)
90 (3.5)
(2.2) 55
(0.4)
7.5
1 .7)
M6 (0
Left
Grounding stud 3 2
B-3
(B-0.1)
)
(0.7
17.5
M6
120 (4.7)
90 (3.5)
45
(1.8)
70 55 50
(2.8) (2.2) (2.0)
Top
Vertical cable guides from
400-mm (15.7 in.) height.
Horizontal cable guides from
800-mm (31.5 in.) width.
Back
B
23 (0.9)
*
A-50 (A-2.0)
A-45 (A-1.8)
A-75 (A-3.0)
725 (28.5)
A
52 (2.0)
55 (2.2)
0
Download our DXF 1
(0.4
) 23 (0.9)
38 (1.5) 27
diagrams from our Backstud 3 4
55 (2.2)
(1.1)
website. M8 3 25
65
Spacial S3DC Accessories
Mounting accessories
Wall-mounting lugs
Set of 4 wall-mounting lugs
● Mounted directly on the rear of the enclosure, either in horizontal or vertical
position.
● Available in two materials, steel and 304L stainless steel. Can be mounted in two
positions, vertical or horizontal, for a wall enclosure separation of 10 mm (0.4 in.).
● Acceptable load:
– Horizontal lug: 180 kg (396.8 lbs).
– Vertical lug: 350 kg (771.6 lbs).
● Supplied with mounting screws and pre-mounted sealing gaskets.
B+110 (B+4.3)
B+90 (B+3.5)
B+70 (B+2.8)
A+70 (A+2.8)
A+90 (A+3.5)
A
A
A-1.8)
A-45
(A-2.8)
A-71
Installation from the outside. B B
66
Spacial S3DC Accessories
Mounting accessories
35 (1.4)
47 (1.9)
35 (1.4)
M8
(0.6)
A-44 (A-1.7) 15 2.5 17.5
(0.1) (0.7)
A
A: width of enclosure
SCALE 0:500
67
Spacial S3DC Accessories
Mounting accessories
A-58 (A-2.3)
45
(1.8)
32.5 (1.3)
Max.
100 kg
Max. 215 mm (220.5 lbs)
(8.5 in.)
2
Min. 150 mm
(5.9 in.)
68
Spacial S3DC Accessories
Mounting accessories
69
Spacial S3DC Accessories
Hoisting accessories
Eyebolts
Set of two M8 eyebolts.
● Material: zinc-coated molded steel.
● The eyebolts are mounted directly to the body of the enclosure.
● Maximum load: 210 kg (463.0 lbs) per enclosure with the sling at 60°.
● Cannot be installed with the canopy in place.
● The reinforcing brackets are attached to the rings.
● The reinforcing brackets also act as a drilling template.
70
Spacial S3DC Accessories
Hoisting accessories
Protection canopy
Direct mounting to the body of the enclosure by 4 M6 screws.
● Material: painted galvanized steel, structured finish, epoxy-polyester powder,
RAL 7035 gray color.
● Delivered with installation hardware.
● To be used for all outdoor installations.
Enclosures: mm (in.)
Catalog number
Width Depth F G H
200 (7.9) 150 (5.9) 36 (1.4) 75 (3.0) 23 (0.9) NSYTJ2015
250 (9.8) 150 (5.9) 36 (1.4) 75 (3.0) 23 (0.9) NSYTJ2515
300 (11.8) 150 (5.9) 36 (1.4) 75 (3.0) 23 (0.9) NSYTJ3015
400 (15.7) 150 (5.9) 36 (1.4) 75 (3.0) 23 (0.9) NSYTJ4015
500 (19.7) 150 (5.9) 36 (1.4) 75 (3.0) 23 (0.9) NSYTJ5015
500 (19.7) 200 (7.9) 36 (1.4) 130 (5.1) 23 (0.9) NSYTJ5020
600 (23.6) 200 (7.9) 36 (1.4) 130 (5.1) 23 (0.9) NSYTJ6020
250 (9.8) 200 (7.9) 36 (1.4) 130 (5.1) 23 (0.9) NSYTJ2520
300 (11.8) 200 (7.9) 36 (1.4) 130 (5.1) 23 (0.9) NSYTJ3020
400 (15.7) 200 (7.9) 36 (1.4) 130 (5.1) 23 (0.9) NSYTJ4020
800 (31.5) 200 (7.9) 36 (1.4) 130 (5.1) 23 (0.9) NSYTJ8020
400 (15.7) 250 (9.8) 42 (1.7) 150 (5.9) 48 (1.9) NSYTJ4025
500 (19.7) 250 (9.8) 42 (1.7) 150 (5.9) 48 (1.9) NSYTJ5025
600 (23.6) 250 (9.8) 42 (1.7) 150 (5.9) 48 (1.9) NSYTJ6025
800 (31.5) 250 (9.8) 42 (1.7) 150 (5.9) 48 (1.9) NSYTJ8025
600 (23.6) 300 (11.8) 42 (1.7) 200 (7.9) 48 (1.9) NSYTJ6030
800 (31.5) 300 (11.8) 42 (1.7) 200 (7.9) 48 (1.9) NSYTJ8030
1000 (39.4) 300 (11.8) 42 (1.7) 200 (7.9) 48 (1.9) NSYTJ10030
1200 (47.2) 300 (11.8) 42 (1.7) 200 (7.9) 48 (1.9) NSYTJ12030
600 (23.6) 400 (15.7) 42 (1.7) 300 (11.8) 48 (1.9) NSYTJ6040
800 (31.5) 400 (15.7) 42 (1.7) 300 (11.8) 48 (1.9) NSYTJ8040
1000 (39.4) 400 (15.7) 42 (1.7) 300 (11.8) 48 (1.9) NSYTJ10040
1200 (47.2) 400 (15.7) 42 (1.7) 300 (11.8) 48 (1.9) NSYTJ12040
15 (0.6) 15 (0.6)
H H
8
3 (0.1) G (0.3) G
12
(0.5)
71
Spacial S3DC Accessories
Locking accessories
Standard locks
Spacial S3DC wall-mounting enclosures are supplied with a screwdriver insert (coin
protected) lock as standard.
● Large range of standardized inserts covering the most common needs.
● Installation and removal with a single screw.
Catalog number of
Description
form insert*
6-mm (0.2 in.) square NSYAEDLS6S3D
7-mm (0.3 in.) square NSYAEDLS7S3D
8-mm (0.3 in.) square NSYAEDLS8S3D
3-mm (0.1 in.) double bar NSYAEDLB3S3D
5-mm (0.2 in.) double bar NSYAEDLB5S3D
CNOMO 6.5-mm (0.3 in.) triangular NSYAEDLT6S3D
8-mm (0.3 in.) triangular NSYAEDLT8S3D
* Delivered with 1 plastic key.
Catalog number of
Description
handle with keys*
1242 NSYAEDL1242S3D
405 NSYAEDL405S3D
421 NSYAEDL421S3D
455 NSYAEDL455S3D
2331A NSYAEDL2331S3D
2433A NSYAEDL2433S3D
3113A NSYAEDL3113S3D
* Delivered with 2 keys.
72
Spacial S3DC Accessories
Locking accessories
Double lock
● Easy mounting in place of the standard lock.
● Material: zamack.
Delivered with 3-mm (0.1 in.) double-bar metal key.
Door hinges
Two models:
● For opening the door to an angle of 180º.
● Spare standard hinges (120º).
● Captive pin, indexed by a spring.
● Batch of 1 hinge, delivered with hardware.
● Material: zamack body for catalog number NSYAEDH180S3D, treated sheet-steel
body for catalog number NSYAEDH120S3D, aluminum pin.
● For the 180º hinge, the maximum allowable load on the door is 20 kg / m2.
● For the 120º hinge, the maximum allowable load on the door is 50 kg / m2.
180º hinge.
120º hinge.
73
Spacial S3DC Accessories
Doors
Inner door
● Sheet-steel door, RAL 7035 gray color.
● Locking with 3-mm (0.1 in.) double-bar lock.
● Maximum load, 30 kg/m2.
● The inner door can be installed directly on the front face of the enclosure or on
the step slides (not supplied as standard).
● It is possible to mount an internal door and a mounting plate together on the step
slides with the standard supply.
● Incompatible with the installation of the door stop and door switch. For further
details, please contact us.
● All doors with a height 700 mm (27.6 in.) are equipped with welded vertical
profiles in order to facilitate cable management. Those profiles allows the
mounting of our standard door cross rail.
Dimensions
Installation on the front of the enclosure (A) or installation on step slides (B).
(A–2.0)
A–51
A
42
(1.7)
(1) D
imension resulting from installation on step slides: B-83 mm (B-3.3 in.).
Dimension resulting from direct installation (without step slides): B-91 mm (B-3.6 in.).
74
Spacial S3DC Accessories
Door accessories
Door-holding system
To hold the door open while working on the enclosure.
● It is installed on the perforated rails of the enclosure doors at the required height.
● Material: polyamide 6 (PA6).
● It can be mounted on enclosures with a height > 400 mm (15.7 in.) [no door cross
rail on heights < 400 mm (15.7 in.)].
● It cannot be installed in the Spacial CRN enclosures.
Description Catalog number
Door-holding system for Spacial S3DC
NSYAEDRS3DPA6
wall-mounting steel enclosure
75
Spacial S3DC Cable management
Cable entries
Fig. 1
223 (8.8) 2 Pg 11
2 Pg 13.5
3 Pg 16
105 (4.1)
2 Pg 21/11
Fig. 2
Example of use. 259 (10.2) Pg 11: 18.6 mm (0.7 in)
2 Pg 11
3 Pg 13.5
4 Pg 16
105 (4.1)
2 Pg 21/11
4 Pg 29/16
2 Pg 36/29 Pg 36/29: 47/37 mm
(1.9/1.5 in)
Fig. 4
460 (18.1) 2 Pg 11
7 Pg 13.5
7 Pg 16
A
163 (6.4)
4 Pg 21/11
4 Pg 29/16
ø 5,5
2 Pg 36/29
B
H
I
76
Spacial S3DC Cable management
Cable entries
Max.: mm (in.)
A B H I R
223 (8.8) 105 (4.1) 180 (7.1) 62 (2.4) 18 (0.7)
259 (10.2) 105 (4.1) 216 (8.5) 62 (2.4) 18 (0.7)
360 (14.2) 163 (6.4) 317 (12.5) 120 (4.7) 32 (1.3)
460 (18.1) 163 (6.4) 417 (16.4) 120 (4.7) 32 (1.3)
A
ø 5,5
B
H
I
77
Spacial S3DCD Disconnect enclosures
Overview
Useful life
Quality of the welding
and the coating.
Easy handling
●R eusable, eco-friendly
packaging.
● No sharp corners.
Easy
maintenance
●R
emovable hinges.
●1
lock command.
Added value
to your work
●Q
uality and
aesthetics.
78
Spacial S3DCD Disconnect enclosures
Overview
Application
● Designed to house the following enclosure disconnect equipment:
*
Ordering
The disconnect switch, operating handle, and
operating mechanism must be ordered from the
disconnect equipment supplier.
79
Spacial S3DCD Disconnect enclosures
Characteristics
Technical characteristics
Enclosure body
●S ingle-piece body (cross-shaped structure). Gutter-shaped front profile with
double fold. Flat rear.
● 4 (or 6**) M8 3 25 shouldered backstuds for installing mounting plates and step
slides, leaving a space of 10 mm (0.4 in.) behind them.
● M6 3 16 grounding screws for equipotential connection between the door and the
body of the enclosure.
● Four direct wall-mounting drill holes [ 10 mm (0.4 in.)] are sealed with plugs to
maintain the degree of protection. Or mount with lugs installed from the outside
(lugs ordered separately, see page 82).
Enclosure door
●W all-mounting enclosure supplied with screwdriver insert lock as standard.
Polyurethane door gasket.
● M6 3 16 grounding screws for equipotential connection between the door and the
body of the enclosure.
● Easily removable, with 20-mm (0.8 in.) return with double thickness for excellent
rigidity, opening to 120°, equipped with 2 or 3 invisible hinges*.
● Door opening to 180° with optional hinges (page 73).
● For heights from 600 mm (23.6 in.), three linked locking points with a single
control point. Maximum load: 50 kg/m2.
● Perforated rails on the door, with drill holes with a diameter of 4.2 mm (0.2 in.)
in steps of 25 mm (1.0 in.):
– 1 vertical rail from the height of 500 mm (19.7 in.) on the side with the hinges.
– 1 vertical rail and 2 horizontal rails from the width of 800 mm (31.5 in.).
– Load on door, see page 65.
Standards
Compliance with enclosure standards IEC 62208 and UL 508A. Environmental
testing to UL 50E.
The Spacial S3DCD wall-mounting enclosures are compliant with the RoHS
directive.
80
Spacial S3DCD Disconnect enclosures
Dimensions
(3)
B+35 (B+1.4)
(1) 4
or 6 M8 3 25 mm (1.0 in.) backstuds with widths
1000 to 1200 mm (39.4 to 47.2 in.). (1) (1)
23 (0.9) (2)
30 (1.2) (1)
105 (4.1)
D
E
(4)
*
4.2 (0.2) (3)
81
Spacial S3DCD Disconnect enclosures
Characteristics
Weight of empty
Height Width Depth Height Width Depth Number of
IP enclosures: Catalog number
(mm) (mm) (mm) (in.) (in.) (in.) doors
kg (lbs)
Installation accessories
Description Catalog number
82
Spacial S3DCD Disconnect enclosures
Dimensions
Microperforated
Plain mounting Plain mounting Adjustable
mounting plate Aluminum upright * Perforated Telequick **
plate painted white plate galvanized brackets
galvanized
83
Spacial CRN - CRNG Steel wall-mounting enclosures
Introduction
PB500377-48
bb Industrial welding process.
non-clean industrial environment. bb Epoxy-polyester painting.
bb Foamed-in polyurethane gasket.
All of the above guarantees quality, water and dust
tightness for years.
Front folded gutter prevents the entry of water, oil or
CRN liquids, ensuring IP66 protection.
PB500369-68
Safety
PB500379-44
For people:
bb Two welded M6 x 15 earth studs welded to the back
and one M6 x 15 stud on the door.
For your installation:
bb Water and dust tightness IP66.
bb Ruggedness IK10 to protect your component from
external impact.
bb Hidden hinges to prevent the removal of the door.
Smart
PB500376-64
CRNG Sealed
PB500110-35
Practical
PB500369-187
Convenient
PB500378
See page 396 for details or consult our web site www.schneider-electric.com.
84
Spacial CRN - CRNG Steel wall-mounting enclosures
Characteristics
CRN CRNG
PB500369-31
PB500373-30
Characteristics Spacial CRN Spacial CRNG
39 dimensions for this metal monobloc. bb 17 dimensions with three-point locking
Back piece joined to the sides using a special system for this metal construction suite
profile forming a protected sealed area. of enclosures.
bb All Spacial CRNG models include
a three-point locking system.
Material Steel
Finish Both externally and internally painted with texturised epoxy-polyester resin
Colour RAL 7035 grey
Ingress protection rating bb IP66 for one-door enclosures
bb IP55 for two-door enclosures according to IEC 60529
Mechanical protection rating IK10 according to IEC 62262
Standards IEC 62208
Certifications bb UL, CUL
bb NEMA 4 for single-door enclosure according to NEMA 250
bb NEMA 12, 12K and 13 for double-door enclosure according to NEMA 250
bb RoHS compliance
Installation bb Given their strength, metal enclosures are particularly well suited to indoor areas
where they may experience impacts
bb Outdoor installation: compliant with IEC 62208 regarding type tests specified in §9.12
(resistance to ultra-violet (UV) radiation) and §9.13 (resistance to corrosion). It is always
advisable to install a canopy to avoid water stagnation on the upper part of the enclosure
Supply Body Body
bb 4 holes for direct mounting bb 4 holes for direct mounting
bb Wall-mounting drill holes sealed with plastic bb Wall-mounting drill holes sealed with plastic
plugs to ensure the degree of protection plugs to ensure water and dust tightness
(supplied as standard) (supplied as standard)
bb Wall-mounting bracket fixed from outside bb Wall-mounting bracket fixed from outside,
(brackets to be ordered separately) specific for large dimensions (to be ordered
bb Direct cable entry separatly). See page 94.
bb Built-in cable-entry plate, flush with the back bb Built-in cable-entry plate, flush with the back
of the enclosure (without foamed-in gasket to of the enclosure (without foamed-in gasket to
facilitate machining) facilitate machining)
bb Insulated cable entries with knock-outs, bb Easy to equip with 4 welded back studs
available as an accessory shouldered 10 mm (6 for widths of 1000 and
bb Easy to equip with 4 welded back studs 1200)
shouldered 10 mm bb Welded earth studs on door and body
Door Door
bb 3-mm standard double-bar lock as bb Three-point locking system for one and two
standard. See page 100 (Wide choice of doors. Standard 5-mm double-bar lock
inserts as accessories). bb Metal hinges - Easily reversible door
bb Foamed-in polyurethane gasket on the bb Door-centring piece on two-door enclosures
doors to guarantee water and dust tightness to ensure proper door alignment
for many years bb Foamed-in polyurethane gasket on the
bb Easily reversible door, fixed with two or doors to guarantee water and dust tightness
three invisible hinges allowing the door to open for many years
to 120º bb Reinforcement on plain doors with welded
bb Reinforcement on plain doors with welded perforated door profiles for equipment
perforated door profiles for equipment mounting
mounting from models NSYCRN54150 bb Delivered with a reusable packaging and
bb Metal hinges - Easily reversible door technical instructions
bb Welded earth studs on door and body
bb Delivered with a reusable packaging and
technical instructions
85
Spacial CRN - CRNG Steel wall-mounting enclosures
Selection guide
PB500109-15
PB500110-12
CRN CRNG
PB500072-10
PB500100-10
PB500101-13
Dimensions (mm) No. of IP Weight Door Plain Silkscreened Microperforated
doors (1)
Height Width Depth Plain with Plain without Glazed without
(A) (B) (C) mounting plate mounting plate mounting plate
86
Spacial CRN - CRNG Steel wall-mounting enclosures
Selection guide
PB500324-16
PB500102-13
PB500103-10
PB500104-12
PB500105-14
PB500111-19
PB500327-18
PB500397-31
PB501865-16
Telequick Bakelite DIN rails Aluminum Step slides Cable entry
chassis upright (7)
Fig. Type of Cable-gland Cable-gland Cable-gland plate FlexiCable
cable entry plate standard plate insulated with FL cut-out
- - - - - 1 0 NSYTLCRNO - - -
- NSYMB32 - - - 1 B NSYTLCRNB - - -
- - - - - 1 0 NSYTLCRNO - - -
NSYMR3025 NSYMB3025 - NSYMDVR3 - 1 A NSYTLCRNA NSYTSACRNA - -
NSYMR3025 NSYMB3025 - NSYMDVR3 NSYSDCR200 1 A NSYTLCRNA NSYTSACRNA NSYTFL13CRNA -
NSYMR33 NSYMB33 NSYMD33 NSYMDVR3 - 1 B NSYTLCRNB NSYTSACRNB NSYTFL13CRNB -
NSYMR33 NSYMB33 NSYMD33 NSYMDVR3 NSYSDCR200 1 B NSYTLCRNB NSYTSACRNB NSYTFL13CRNB -
NSYMR34 NSYMB43 - NSYMDVR3 NSYSDCR200 1 C NSYTLCRNC NSYTSACRNC NSYTFL21CRNC -
- NSYMB43 - NSYMDVR3 - 1 B NSYTLCRNB NSYTSACRNB NSYTFL13CRNB -
NSYMR43 NSYMB43 NSYMD43 NSYMDVR4 - 1 B NSYTLCRNB NSYTSACRNB NSYTFL13CRNB -
NSYMR43 NSYMB43 NSYMD43 NSYMDVR4 NSYSDCR200 1 B NSYTLCRNB NSYTSACRNB NSYTFL13CRNB -
NSYMR44 - - NSYMDVR4 NSYSDCR200 1 C NSYTLCRNC NSYTSACRNC NSYTFL21CRNC -
NSYMR46 NSYMB64 - NSYMDVR4 NSYSDCR250 1 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR46 NSYMB64 - NSYMDVR4 NSYSDCR300 1 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR54 NSYMB54 NSYMD54 NSYMDVR5 - 2 B NSYTLCRNB NSYTSACRNB NSYTFL13CRNB -
NSYMR54 NSYMB54 NSYMD54 NSYMDVR5 NSYSDCR200 2 C NSYTLCRNC NSYTSACRNC NSYTFL21CRNC -
NSYMR54 NSYMB54 NSYMD54 NSYMDVR5 NSYSDCR250 2 C NSYTLCRNC NSYTSACRNC NSYTFL21CRNC -
NSYMR55 - - NSYMDVR5 NSYSDCR250 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR64 NSYMB64 NSYMD64 NSYMDVR6 - 2 B NSYTLCRNB NSYTSACRNB NSYTFL13CRNB -
NSYMR64 NSYMB64 NSYMD64 NSYMDVR6 NSYSDCR200 2 C NSYTLCRNC NSYTSACRNC NSYTFL21CRNC -
NSYMR64 NSYMB64 NSYMD64 NSYMDVR6 NSYSDCR250 2 C NSYTLCRNC NSYTSACRNC NSYTFL21CRNC -
NSYMR65 NSYMB65 - NSYMDVR6 - 2 B NSYTLCRNB NSYTSACRNB NSYTFL13CRNB -
NSYMR65 NSYMB65 - NSYMDVR6 NSYSDCR200 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR65 NSYMB65 - NSYMDVR6 NSYSDCR250 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR66 - NSYMD66 NSYMDVR6 NSYSDCR200 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR66 - NSYMD66 NSYMDVR6 NSYSDCR250 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR66 - NSYMD66 NSYMDVR6 NSYSDCR300 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR68 - - NSYMDVR6 NSYSDCR300 2 E NSYTLCRNC (4) NSYTSACRNC NSYTFL21CRNC -
NSYMR75 NSYMB75 NSYMD75 NSYMDVR7 NSYSDCR200 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR75 NSYMB75 NSYMD75 NSYMDVR7 NSYSDCR250 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR86 NSYMB86 NSYMD86 NSYMDVR8 NSYSDCR200 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR86 NSYMB86 NSYMD86 NSYMDVR8 NSYSDCR250 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR86 NSYMB86 NSYMD86 NSYMDVR8 NSYSDCR300 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR88 - - NSYMDVR8 NSYSDCR200 2 E NSYTLCRNC (4) NSYTSACRNC (5) NSYTFL21CRNC -
NSYMR88 - - NSYMDVR8 NSYSDCR300 2 E NSYTLCRNC (4) NSYTSACRNC (5) NSYTFL21CRNC -
NSYMR106 NSYMB106 - NSYMDVR10 NSYSDCR250 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR106 NSYMB106 - NSYMDVR10 NSYSDCR300 2 D NSYTLCRND NSYTSACRND NSYTFL21CRND -
NSYMR108 NSYMB108 NSYMD108 NSYMDVR10 NSYSDCR250 2 E NSYTLCRNC (4) NSYTSACRNC (5) NSYTFL21CRNC -
NSYMR108 NSYMB108 NSYMD108 NSYMDVR10 NSYSDCR300 2 E NSYTLCRNC (4) NSYTSACRNC (5) NSYTFL21CRNC -
87
Spacial CRN - CRNG Steel wall-mounting enclosures
Selection guide
PB500152-33
PB500381-19
PB500382-16
DB300116-13
DB300117-13
DB300118-13
PB500383-21
PB500384-14
PB500385-13
CRN CRNG
88
Spacial CRN - CRNG Steel wall-mounting enclosures
DB300089-77
Selection guide
PB500156-25
PB502578-15
PB502580-10
PB502548-20
PB500386-26
PB500331-13
PB500387-12
PB500453-21
PB501821-9
Kit for Post- Single plinths side plate** Single plinths front Supporting Coupling Canopies Floor stand kit Support bracket for
heavy mounting plate** pole plates for WM enclosure with anti-tilt
loads* device kit and reinforcement
100 mm 200 mm 100 mm 200 mm 300 mm 400 mm 1400 mm***
- - - - - - - - - - - NSYCOCNS1400
- - - - - - - - - - - NSYCOCNS1400
- - - - - - NSYCOCN80 - NSYTJ2015 - - NSYCOCNS1400
- - - - - - NSYCOCN80 NSYCHCOA NSYTJ2515 - - NSYCOCNS1400
- - - - - - NSYCOCN80 NSYCHCOA NSYTJ2520 - - NSYCOCNS1400
- NSYSFPSC30 - - - - NSYCOCN80 NSYCHCOB NSYTJ3015 - - NSYCOCNS1400
- NSYSFPSC30 - - - - NSYCOCN80 NSYCHCOB NSYTJ3020 - - NSYCOCNS1400
- NSYSFPSC40 - - - - NSYCOCN80 NSYCHCOC NSYTJ4020 - - NSYCOCNS1400
- - - - - - - - - - - NSYCOCNS1400
- NSYSFPSC30 - - - - NSYCOCN80 NSYCHCOB NSYTJ3015 - - NSYCOCNS1400
- NSYSFPSC30 - - - - NSYCOCN80 NSYCHCOB NSYTJ3020 - - NSYCOCNS1400
- NSYSFPSC40 - - - - NSYCOCN80 NSYCHCOC NSYTJ4020 - - NSYCOCNS1400
- NSYSFPSC60 - - - - NSYCOCN80 NSYCHCOD NSYTJ6025 - - NSYCOCNS1400
- NSYSFPSC60 NSYSPS3100SD NSYSPS3200SD NSYSPF6100 NSYSPF6200 NSYCOCN80 NSYCHCOD NSYTJ6030 - - NSYCOCNS1400
- NSYSFPSC40 - - - - NSYCOCN80 NSYCHCOB NSYTJ4015 - - NSYCOCNS1400
- NSYSFPSC40 - - - - NSYCOCN80 NSYCHCOC NSYTJ4020 - - NSYCOCNS1400
- NSYSFPSC40 - - - - NSYCOCN80 NSYCHCOC NSYTJ4025 - - NSYCOCNS1400
- NSYSFPSC50 - - - - NSYCOCN80 NSYCHCOD NSYTJ5025 - - NSYCOCNS1400
- NSYSFPSC40 - - - - NSYCOCN80 NSYCHCOB NSYTJ4015 - - NSYCOCNS1400
- NSYSFPSC40 - - - - NSYCOCN80 NSYCHCOC NSYTJ4020 - - NSYCOCNS1400
- NSYSFPSC40 - - - - NSYCOCN80 NSYCHCOC NSYTJ4025 - - NSYCOCNS1400
- NSYSFPSC50 - - - - NSYCOCN80 NSYCHCOB NSYTJ5015 - - NSYCOCNS1400
- NSYSFPSC50 - - - - NSYCOCN80 NSYCHCOD NSYTJ5020 - - NSYCOCNS1400
- NSYSFPSC50 - - - - NSYCOCN80 NSYCHCOD NSYTJ5025 - - NSYCOCNS1400
- NSYSFPSC60 - - - - NSYCOCN80 NSYCHCOD NSYTJ6020 - - NSYCOCNS1400
- NSYSFPSC60 - - - - NSYCOCN80 NSYCHCOD NSYTJ6025 - - NSYCOCNS1400
- NSYSFPSC60 NSYSPS3100SD NSYSPS3200SD NSYSPF6100 NSYSPF6200 NSYCOCN80 NSYCHCOD NSYTJ6030 - - NSYCOCNS1400
- NSYSFPSC80 NSYSPS3100SD NSYSPS3200SD NSYSPF8100 NSYSPF8200 NSYCOCN80 NSYCHCOC (2) NSYTJ8030 - - NSYCOCNS1400
- NSYSFPSC50 - - - - NSYCOCN80 NSYCHCOD NSYTJ5020 - - NSYCOCNS1400
89
Spacial CRN - CRNG Steel wall-mounting enclosures
Dimensions
CRN
B C B C
DB300105EN-176
21 21
40
40
50
A-125
10 10
A-44
A-125
B-145
A-75
A-50
A- 5
A
83
B-44
A-75
A- 5
A-44
83
A-50
A
25*
B-133
B-44
50
B-50
B-75
B - 50 800
B - 75
B -5
B - 76.4* B - 76.4*
B- 5 B- 5
A: Enclosure height
B: Enclosure width
C: Enclosure depth
90
Spacial CRN - CRNG Steel wall-mounting enclosures
Dimensions
CRNG
B-180 B
DB300107-61
DB300108-55
DB300109-20
DB300110-16
30 (1)
(2)
Detail (1)
A-75 (3)
A-45 (4)
A-200
A
23 (2)
DB300111-29
105
(2) Ø 10
(1)
C-23
B-75 (3) C
B-45 (4)
Detail (2)
DB300112-SE
J
800 300-400 95 320 105 400
L
C-55
C-15
C-28
1000 (5) 300 125 420 105 500
1000 300-400 95 420 105 500
(3) (3)
1200 300 95 420 105 500
35
400 125 420 105 600 M
(1) Four M8 x 25 back studs. Cable entry type H: enclosure width ≥ 800 mm.
(2) Two M6 x 17.5 earth studs.
(3) Spacing between the studs. 470
DB300113
195
A: Enclosure height
B: Enclosure width
C: Enclosure depth Cable entry type G: enclosure width 600 mm.
Dimensions
N of
M
the door-reinforcement
N profiles (6)
D
DB300114EN-51
105
91
Spacial CRN - CRNG Steel wall-mounting enclosures
Specific accessories overview
Composition accessories
PB500371-74
Mounting Floor
PB500385-38
PB500330-34
Page 94 Page 97
Coupling Hoisting
PB500335-31
PB500338-37
Page 98 Page 99
PB500384-32
Mounting accessories
PB500072-20
Page 236
92
Spacial CRN - CRNG Steel wall-mounting enclosures
Common accessories overview
Cable management
PB502439-55
PB500966-40
PB500958-22
Page 286 Page 289
Thermal management
Heaters Ventilation Cooling units
PB502050-29
PB501044-26
PB502614-15
Page 454 Page 412 Page 435
Others
Earthing
PB500217-29
Page 302
93
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Mounting
CRN CRNG
PB500385-42
PB502980-26
PB502979-16
New
Characteristics Wall-mounting kit for Wall-mounting brackets Kit for heavy loads
Spacial CRN
enclosures
They are fixed from the outside Set of 4 wall-mounting brackets. Kit made up of 2 reinforcement
and can be positioned vertically Mounted directly on the rear of the enclosure, pieces.
or horizontally indistinctly. either in horizontal or vertical position. To be mounted before installing
Not included in the standard Two types of position, for a wall-enclosure separation the mounting plate in top
supply. of 10 mm. position with the standard lugs
Do not use for dynamic loads. (to be ordered separately).
Material Passivated zinc-coated steel Steel AISI 304 stainless-steel Steel
or stainless-steel
Maximum load 150 kg 150 kg 400 kg
Supply 4 wall-mounting brackets Supplied with mounting screws and pre-mounted sealing -
gaskets
References
Steel Stainless-steel
NSYPFCR NSYPFC2X NSYAEFPFSC NSYAEFPFXSC NSYAEFAHLBSC
A: Enclosure height
DB300872
B: Enclosure width
B – 50
DB300119-45
B + 58
A + 58
A – 50
A
B
B – 50 B Installation from the outside.
B-14
A + 58
A – 50
B-74
A
B B+40
B
A+40
DB300120-49
A+40
A
A-44
A-44
B
Vertical position. Horizontal position.
You will find the weights of the Spacial CRN - CRNG enclosures without mounting plate in the selection guide on page 86.
94
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Mounting
Characteristics PB500156-99
Post-mounting device for Spacial steel enclosure
For indoor installations on posts with a maximum circumference of 675 mm
(minimum diameter 150 mm and maximum diameter 215 mm).
Rail fixed to the inserts in the rear of the enclosure with 8-mm screws.
They allow the mounting of protection canopies.
Material Galvanised steel
Maximum load 100 kg
Width (mm) A (mm) References
300 295 NSYSFPSC30
400 395 NSYSFPSC40
500 495 NSYSFPSC50
600 595 NSYSFPSC60
800 795 NSYSFPSC80 2,5-3 Nm
DB300090EN-60
A
A-58
45
32.5
DB300091-53
Max.
Max. Ø 215 mm 100 kg
Min. Ø 150 mm
95
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Mounting
PB500339-SE
PB501821-18
PB500454-43
102 x 65 mm
800 mm
PB500453-37
Characteristics Support pillar Support bracket for Floor Stand Kit for wall-mounting
enclosure with anti-tilt kit enclosure
and reinforcement
The support pillar is fixed directly to The support bracket for Spacial S3D and Set of 2 feet, elevating wall-mounting enclosures.
the bottom face of the Spacial steel Spacial CRN steel enclosures is used Cut-outs needed on enclosure – drilling template
enclosure by means of an adapter plate. when the enclosure cannot be hung from provided with the kit.
The latter, to be ordered in addition to a wall or a post.
the pillar, replaces the cable-gland plate. Suitable for outdoor use.
Overall height of the support foot: 800 mm. Compatible with other enclosure ranges:
Mounting possible on all enclosures with bb S3X (stainless-steel),
dimensions up to 600 x 400 x 250 mm bb S3HF (EMC),
(except 200 x 200 x 150 and bb Thalassa (polyester).
250 x 200 x 150 enclosures). Maximum enclosure dimensions:
1000 x 800 x 300 mm.
Floor attachment by standard M12
fastenings.
Material Extruded aluminium Steel Steel
Finish Polyester powder Painted Polyester powder
Colour RAL 7035 grey RAL 7035 grey RAL 7035 grey
Thickness - - bb Sides: 2.5 mm
bb Base: 3 mm
Maximum load - 120 kg 250 kg
Supply - - 2 platform feet (right and left) & mounting elements
Height (mm) Reference References Enclosure depth Foot height References
mm Inches mm Inches
800 NSYCOCN80 - - - - - -
1400 - NSYCOCNS1400 - - - - -
1800 - NSYCOCNS1800 - - - - -
- - - 300* 12 300 12 NSYWMK33
- - - 400** 16 300 12 NSYWMK43
- - - 300* 12 450 18 NSYWMK34
798
250
160
50
370
96
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Floor
PB502581-18
PB502580-17
PB502578-30
PB502579-30
Characteristics Front and rear plinth Plinth side panels
The front and rear of the plinth consists of 4 corners They are fixed to the corner
with 2 or 4 panels. of the plinth by 2 mounting screws.
Material Folded sheet steel, corner Folded sheet steel
with a thickness of 2.5 mm
Finish Painted with epoxy-polyester resin Painted with epoxy-polyester resin
Colour RAL 7022 grey RAL 7022 grey
Ingress protection rating IP30 IP30
Mechanical protection rating IK10 IK10
Installation It is necessary to order separately the plinth mounting kit (ref. NSYAPFWM) composed by mounting hardware and drilling jig
Supply bb Height 100 mm: 4 corners, 2 panels (front and rear), bb Height 100 mm: 2 side panels, 4 corner covers and
4 corner covers and mounting elements mounting elements
bb Height 200 mm: 4 corners, 4 panels (2 front and 2 rear), bb Height 200 mm: 4 side panels (height of 100 mm,
4 corner covers and mounting elements 2 for each side), 4 corner covers and mounting elements
References
Width Depth 100 mm 200 mm 100 mm 200 mm
(mm) (mm)
600 - NSYSPF6100 NSYSPF6200 - -
800 - NSYSPF8100 NSYSPF8200 - -
1000 - NSYSPF10100 NSYSPF10200 - -
1200 - NSYSPF12100 NSYSPF12200 - -
- 300 - - NSYSPS3100SD NSYSPS3200SD
- 400 - - NSYSPS4100SD NSYSPS4200SD
PB502592-21
PB502591-18
PB502590-30
PB502589-30
Plinth height 100 mm Plinth height 100 mm Plinth height 200 mm Plinth height 200 mm
(4 corners + front and back) (Set of 2 side panels) (4 corners + front and back) (Set of 2 side panels)
97
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Coupling
PB500336-34
PB500335-62
Version without cable entry.
PB500337-26
Installation example. Version with cable entry.
DB300078-27
Ø6
Version with
cable entry.
Ø6
DB300079-37
399/599***
=
14
9
19.5 25
98
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Hoisting
PB500338-29
Characteristics Eyebolts
Set of two M8 eyebolts. They are fixed directly to the body of the floor-standing enclosure. Cannot be installed with the canopy in place.
Material Zinc-coated moulded steel
Maximum load 210 kg per enclosure when slinging at 60°
Options Have your cut-outs made by our configured service, page 6. Paint touch-up pen, page 303.
Supply Reinforcing brackets attached to the rings (these brackets also act as a drilling template)
Reference
Batch of 2 M8 eyebolts NSYAELYTCRG8
DB300081-20
Protection
PB500329-40
15 15
H
F
Ø8 H
G G
3
12
99
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Locking systems
CRN
PB500389-42
Lock for Spacial CRN enclosure
NSYCDB3 3 mm Ø standard double-bar lock.
By mounting the wing nut to the lock, the double-bar lock becomes a handle lock.
bb Operation using:
vv wing key ref.: NSYDBP ,
vv key NSYLDB5 (according to DIN 43668) .
Type of lock Insert references Key references
vv 6 mm NSYTC6CRN NSYLC7
vv 7 mm NSYTC7CRN NSYLC7
vv 8 mm NSYTC8CRN NSYLC8
7 mm NSYTT7CRN NSYLT8
8 mm NSYTT8CRN NSYLT8
DB300121-22
PB500390-65
Padlock
Ø 8 mm. Stainless-steel. Ø 7.5 mm / Ø 10 mm.
References
NSYKPLM NSYCBCCRN
DB300123-31
Ø 6,5
100
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Locking systems
CRNG
PB500392-21
PB500393-17
PB500394-26
Lock for Spacial CRNG enclosure (three-point lock)
Transformation of the standard lock to standarised Transformation of the standard lock to a retractable
variations in enclosures with three-point locks three-point lock with various types of insterts
bb Standard 5 mm double-bar lock for CRNG models.
bb Operation using: key NSYLDB5 (according to DIN 43668) .
Type of insert Insert references Key references* Type of insert Insert references Key references*
Key operated bar
vv 6 mm square NSYTC6ML NSYLC7 NSYTEDB5ML NSYLDB5
lock
vv 7 mm square NSYTC7ML NSYLC7 vv 7 mm square lock NSYTEC7ML NSYLC7
Handle lock
Lock operated with
operated using key NSYTL405SML NSYTERML
reinforced key
405 (included)
DB300124-16
DB300745-47
Padlocking accessories
Padlocking system, positioned Padlocking system, to block
around the long rectangular access to the retractable
escutcheon of the enclosures, handle, for a Ø 9 mm padlock.
to block access to the lock,
for a Ø 9 mm padlock.
References
NSYBCPL NSYBCME
DB300617-27
DB300618-13
101
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Cable-gland plates
CRN
PB500396-31
PB500395-34
PB500327-33
Characteristics Standard With FL cut-outs Insulated
The cable-gland plate for Cable-gland plate. bb With a polyurethane
Spacial CRN guarantees water sealing gasket.
and dust tightness. bb Excellent thermal
resistance.
bb Pre-marked holes
for cable entrie plates.
Material Steel Steel Self-extinguishing ABS
with 30 % fibreglass
Colour RAL 7035 RAL 7035 RAL 7035
Installation bb Mounting with screws Mounting with screws Pre-marked holes with
bb It is flattened with the body diameter Pg for coupling of
cable glands, membrane
glands, tubes, etc
Supply bb Included as a standard with Includes cut-outs for FL13 -
the Spacial CRN enclosure and FL21 according to
bb It is delivered with a separate the dimension
seal: it allows easy cut-outs
with no risk of damaging the
seal and can be easily
repainted
Width (mm) Depth (mm) To be coupled Fig. References
with entry (only insulated)
200 150 0 - NSYTLCRNO - -
250 150/200 A 1 NSYTLCRNA NSYTFL13CRNA NSYTSACRNA
300 150/200 B 2 NSYTLCRNB NSYTFL13CRNB NSYTSACRNB
400/500 150 B 3 NSYTLCRNB NSYTFL13CRNB NSYTSACRNB
400 200/250 C 3 NSYTLCRNC NSYTFL21CRNC NSYTSACRNC
500/600 200/250/300 D 4 NSYTLCRND NSYTFL21CRND NSYTSACRND
800 200/250/300 E* - NSYTLCRNC NSYTFL21CRNC -
200/250/300 E** 3 - - NSYTSACRNC
DB300594-81
A
A
ø 4,2 B ø 5,5
B
R R
H H
I I
Fig. 1 Fig. 3
DB300126EN-93
PB500397-88
223 2 PG 11 360 2 PG 11
2 PG 13.5 4 PG 13.5
3 PG 16 5 PG 16
105
2 PG 21 / 11 2 PG 21 / 11
163
4 PG 29 / 16
2 PG 36 / 29
Fig. 2 Fig. 4
259 2 PG 11 460 2 PG 11
Example of use (insulated). 3 PG 13.5 7 PG 13.5
4 PG 16 7 PG 16
105
2 PG 21 / 11 4 PG 21 / 11
163
4 PG 29 / 16
2 PG 36 / 29
102
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Cable-gland plates
CRNG
PB500327-33
PB500324-28
PB501865-30
Characteristics Standard For membrane glands FlexiCable
Cable entries. Cable entries. FlexiCable is an innovative cable-gland plate
for simple and fast cable entrance.
There is no need to drill holes: the creation
of the cable entrances takes a few seconds.
bb Cable diameter: up to 26 mm.
Material Steel painted with textured Steel painted with textured -
epoxy-polyester resin epoxy-polyester resin
Colour RAL 7035 RAL 7035 -
Ingress protection rating - The membranes are built to IP55
accommodate water and dust
tight cable entries in insulated
material (flame classification
V0), guaranteeing IP65 (to be
ordered separately)
Certifications - - bb Fire resistant 650°C following
IEC 60695-2-11
bb Tested on short-circuit
effect 250 A, 25 kA following IEC 61439-1
Installation bb Surface with a grid Mounting with screws Installation possibilities: replaces cable-
pattern in 25 mm intervals gland plate (S3D or CRN-G) or directly
to facilitate perforation on enclosure
bb Mounting with screws
Other characteristics - - Exists in 5 sizes matching 46 sizes
(132 models) of Spacial S3D steel
wall-mounting enclosures
Supply Standard supply with the - bb 1 metallic frame with pre-mounted
Spacial CRNG enclosures membrane
bb 1 gasket
bb Hardware
Width Depth To be Dimensions References Effective cable References
(mm) (mm) coupled A x B (mm) entrance dimensions
with entry (mm)
600 300-400 - 495 x 220 - - 428 x 153 NSYTLGME
400 G NSYTLG NSYTLG2FL** - -
800 300-400 H* 345 x 130 NSYTLD NSYTLDFL** - -
- - - - 2 x NSYTLDME
1000-1200 300-400 H* 445 x 130 NSYTLE NSYTLEFL** - -
- - - - 2 x NSYTLEME
DB300127-24
DB300128EN-31
PB501867-33
PB502035-28
P
62.5
B
Ø6
P P
A 30.5 194
P = 25 mm A
Reference
NSYTLREP
* 2 entries.
** FL21 cut-outs.
103
Spacial CRN - CRNG Steel wall-mounting enclosures
Accessories
Door
PB500384-54
Internal door
bb 3-mm double-bar lock.
bb Not compatible with mounting with door stop and door contact.
Consult us.
Material Sheet-steel
Colour RAL 7035 grey
Installation bb The internal door can be mounted either on the front face of
the enclosure or on step slides (not supplied as standard)
bb To mount an inner door and a mounting plate at the same time
on the step slides, is possible as standard
Maximum load 30 kg/m²
Dimensions (mm) References
Height (A) Width (B)
400 300 NSYPIN43
500 400 NSYPIN54
600 400 NSYPIN64
700 500 NSYPIN75
800 600 NSYPIN86 (1)
1000 600 NSYPIN106 (1)
800 NSYPIN108 (1)
1200 600 NSYPIN126
800 NSYPIN128 (1)
1 2
DB300125-67
27
A-51
40
A
32
23 23
min. = 30
10
NSYPIN... internal door fixed to the adjustable
NSYSDCR support. In this case, both the internal door
and the mounting plate may be depth adjustable.
(1) Equipped with welded vertical profiles in order to facilitate cable management.
* Dimension C according to general table on page 88.
** Except H 1200 x W 600: 38.3.
*** Except H 1200 x W 600: 59 and H 1200 x W 800: 52.
104
105
Steel
floor-standing
enclosures
106
Universal Enclosures Steel floor-standing enclosures
Contents
PB500067-39
Steel floor-standing enclosures
Introduction 108
Characteristics 110
Dimensions 112
Selection guide 114
Specific accessories overview 120
Common accessories overview 122
Accessories 124
PB500205-22
107
Spacial SM - SF Steel floor-standing enclosures
Introduction
Robust
PB502402-26
SM bb Body made as a single piece with welded rear panel.
bb Front part forming a rigid frame with welded corners.
PB502403-38
PB502404-30
bb Door rails, which can be height-adjustable and used
for mounting cables.
PB502401-55
Protection
PB500469-32
Comfort
PB502405-8
See page 396 for details or consult our web site www.schneider-electric.com
108
Spacial SM - SF Steel floor-standing enclosures
Introduction
PB502414-50
bb Structure formed from a single 15/10e-mm
steel enclosure. galvanised-steel section, with a high rigidity.
bb Vertical uprights screwed together with connections
of full steel. Placement and screwing of the 4 vertical
SF uprights at the corners of the top and bottom frames.
Mounting by 8 screws, one at each corner of the
enclosure.
Adapts to all your needs. bb Capable of withstanding 1000 kg distributed
in its volume.
Assembled delivery for a
ready-to-use solution. Reliable
PB500492-32
bb The design of the profile creates a double protective
PB502412-55
Aesthetics
PB502415-55
The built-in panels and handle with new design give the
enclosure a new appearance.
Comfort
PB502416-8
PB502417-48
Simple
PB502418-20
Accessible
PB502419-12
Fast
PB502424-16
PB502425-40
109
Spacial SM - SF Steel floor-standing enclosures
Characteristics
SM
PB502401-32
110
Spacial SM - SF Steel floor-standing enclosures
Characteristics
SF SF kit
PB502412-34
PB502428-43
Suitable enclosures Spacial SF - Assembled supply Suitable enclosures Spacial SF - Supplied as a kit
Structure made up of vertical uprights joined with top and bottom frames Structure made up of vertical uprights joined with top and bottom frames
Panels and doors built into the structure Panels and doors built into the structure
Formed from a single section and perforated structure with a pitch of 25 mm Formed from a single section and perforated structure with a pitch of 25 mm
Basic composition Basic composition
bb Front door with a reinforment frame (horizontal rails height-adjustable) bb Front door with a reinforment frame (horizontal rails height-adjustable)
and a trim plate bb The double doors are overlapping, with system for mounting the left door
bb The double doors are overlapping, with system for mounting the left door bb Door reversible, 120º openning
bb Door reversible, 120º openning bb Rear panel to be screwed on with captive screws
bb Rear panel screwed on with captive screws bb Removable roof delivered with top frame
bb Removable roof bb 4 locking points system with handle 5 mm double-bar insert
bb 4 locking points system with handle 5 mm double-bar insert bb Mounting plate support brackets delivered with top & bottom frames kit
bb Mounting plate support brackets bb Mounting plate sliding rails delivered with top & bottom frames kit
bb Mounting plate sliding rails bb 2 quick mounting cross rails delivered with top & bottom frames kit
bb 2 quick mounting cross rails
Versions / Configurations
Versions / Configurations bb Uprights kit
bb Modular enclosure with plain door and mounting plate bb Top and bottom frames kit
bb Modular enclosure with plain door and without mounting plate bb Rear panel kit
bb Modular enclosure with transparent Securit® glass door and without bb Door kit (plain or transparent)
mounting plate
Protection of personnel
Protection of personnel Earthing accessories needed to ensure the grounding continuity,
Earthing accessories needed to ensure the grounding continuity, see page 300
see page 300
Sheet steel
Textured finish with epoxy-polyester powder
RAL 7035 grey
IP55 according to IEC 60529 IP55 according to IEC 60529
IK10 for plain door and IK08 for transparent door according to IEC 62262 IK10 for plain door and IK08 for transparent door according to IEC 62262
Compliance with enclosure standard IEC 62208 and the RoHS directive
BV, DNV, UL and cUL* BV, DNV, UL and cUL*
*1 door: 1, 3R, 12, 12K *1 door: 1, 3R, 12, 12K
*2 doors: 1, 3R, 12, 12K *2 doors: 1, 3R, 12, 12K
Indoor / Outdoor* installation Indoor / Outdoor* installation
* Compliant with IEC 62208 regarding type tests specified in §9.12 * Compliant with IEC 62208 regarding type tests specified in §9.12
(resistance to UV radiation) and §9.13 (resistance to corrosion) (resistance to UV radiation) and §9.13 (resistance to corrosion)
Outdoor installation: canopy needed to avoid water stagnation on the upper Outdoor installation: canopy needed to avoid water stagnation on the upper
part of the enclosure, see page 138 part of the enclosure, see page 138
1000 1000
bb Side panels options, see page 124 bb Door trim plates, see page 142
bb Enclosure suites options, see page 126 bb Side panels options, see page 124
bb Plinths, heights 100 mm and 200 mm, see page 132 bb Enclosure suites options, see page 126
bb Cable-gland plates, see page 134 bb Plinths, heights 100 mm and 200 mm, see page 132
bb Lifting systems, see page 136 bb Cable-gland plates, see page 134
bb Roof options, see page 138 bb Lifting systems, see page 136
bb Door accessories, see page 142 bb Roof options, see page 138
bb Other locking options, see page 144 bb Other locking options, see page 144
bb Mounting plates and Telequick system, see page 242. bb Mounting plates and Telequick system, see page 242
111
Spacial SM - SF Steel floor-standing enclosures
Dimensions
SM
B-205
DB300180EN-176
B B C
B-150
17
45
18 x 18
Ø8
Ø 5.2
A-150
A
A-150
A-62
A
A-150
A-150
A-90
A
A-262
B/2-150
17
45 C+5 B
B-120 B-280
B/2-180
C-130
C-125
C-130
B-125
1200/1600
600/800
112
Spacial SM - SF Steel floor-standing enclosures
Dimensions
SF SF kit
DB300852EN
Ø9 See
25
B-205 Ø 0.52 detail A
min. 85
max. C - 90
18 x 18
A-262
A - 90
A-150
A-150
A-150
A+9
A
28.6
B B
9
B-125 B-125
60
C-90
C-125
C-125
C-90
C
C
Ø 16 Ø 13 B-90
B-90
Detail A
See B-219 B-219
detail B
5
42
Detail B
113
Spacial SM - SF Steel floor-standing enclosures
Selection guide
SM
PB500480-12
PB500119-14
PB500481-12
PB500125-18
PB500123-18
PB500124-18
PB500126-13
Characteristics Door Plinth
114
Spacial SM - SF Steel floor-standing enclosures
Selection guide
SM
PB500473-12
PB500475-12
PB500477-7
PB500482-10
PB500483-13
Characteristics Inner door Mounting Vertical uprights Off-centre 19" Centred 19"
plate swing rack swing rack
Dimensions (mm) No. of Standard Technical
doors
H W D
(A) (B) (C)
1200 800 300 1 - NSYMP128 - NSYTVR12 - -
1000 300 2 - NSYMP1210 - NSYTVR12 - -
1200 400 2 - NSYMP1212 - NSYTVR12 - -
1400 600 300 1 - NSYMP146 - NSYTVR14 - -
400 1 - NSYMP146 - NSYTVR14 - -
800 300 1 - NSYMP148 - NSYTVR14 NSYRSW27 NSYRSWC27
400 1 - NSYMP148 - NSYTVR14 NSYRSW27 NSYRSWC27
1000 400 2 - NSYMP1410 - NSYTVR14 - -
1200 400 2 - NSYMP1412 - NSYTVR14 - -
1600 600 300 1 NSYID166 NSYMP166 - NSYTVR16 - -
400 1 NSYID166 NSYMP166 - NSYTVR16 - -
800 300 1 NSYID168 NSYMP168 - NSYTVR16 NSYRSW31 NSYRSWC31
400 1 NSYID168 NSYMP168 - NSYTVR16 NSYRSW31 NSYRSWC31
1000 300 2 - NSYMP1610 - NSYTVR16 - -
400 2 - NSYMP1610 - NSYTVR16 - -
1200 300 2 - NSYMP1612 - NSYTVR16 - -
400 2 - NSYMP1612 - NSYTVR16 - -
1800 600 300 1 NSYID186 NSYMP186 NSYVR18 NSYTVR18 - -
400 1 NSYID186 NSYMP186 NSYVR18 NSYTVR18 - -
500 1 NSYID186 NSYMP186 NSYVR18 NSYTVR18 - -
800 300 1 NSYID188 NSYMP188 NSYVR18 NSYTVR18 NSYRSW36 NSYRSWC36
400 1 NSYID188 NSYMP188 NSYVR18 NSYTVR18 NSYRSW36 NSYRSWC36
500 1 NSYID188 NSYMP188 NSYVR18 NSYTVR18 NSYRSW36 NSYRSWC36
600 1 NSYID188 NSYMP188 NSYVR18 NSYTVR18 NSYRSW36 NSYRSWC36
1000 400 1 NSYID1810 NSYMP1810 NSYVR18 NSYTVR18 - -
400 2 NSYID1810 NSYMP1810 NSYVR18 NSYTVR18 - -
500 2 NSYID1810 NSYMP1810 NSYVR18 NSYTVR18 - -
1200 400 2 - NSYMP1812 NSYVR18 NSYTVR18 - -
500 2 - NSYMP1812 NSYVR18 NSYTVR18 - -
1600 400 2 - NSYMP1816 NSYVR18 NSYTVR18 - -
500 2 - NSYMP1816 NSYVR18 NSYTVR18 - -
2000 600 300 1 NSYID206 NSYMP206 NSYVR20 NSYTVR20 - -
400 1 NSYID206 NSYMP206 NSYVR20 NSYTVR20 - -
500 1 NSYID206 NSYMP206 NSYVR20 NSYTVR20 - -
800 300 1 NSYID208 NSYMP208 NSYVR20 NSYTVR20 NSYRSW40 NSYRSWC40
400 1 NSYID208 NSYMP208 NSYVR20 NSYTVR20 NSYRSW40 NSYRSWC40
500 1 NSYID208 NSYMP208 NSYVR20 NSYTVR20 NSYRSW40 NSYRSWC40
600 1 NSYID208 NSYMP208 NSYVR20 NSYTVR20 NSYRSW40 NSYRSWC40
1000 400 2 NSYID2010 NSYMP2010 NSYVR20 NSYTVR20 - -
500 2 NSYID2010 NSYMP2010 NSYVR20 NSYTVR20 - -
1200 400 2 - NSYMP2012 NSYVR20 NSYTVR20 - -
500 2 - NSYMP2012 NSYVR20 NSYTVR20 - -
600 2 - NSYMP2012 NSYVR20 NSYTVR20 - -
1600 400 2 - NSYMP2016 NSYVR20 NSYTVR20 - -
500 2 - NSYMP2016 NSYVR20 NSYTVR20 - -
600 2 - NSYMP2016 NSYVR20 NSYTVR20 - -
115
Spacial SM - SF Steel floor-standing enclosures
Selection guide
SF
PB500511-10
PB500112-15
PB500113-13
PB500114-7
PB500115-18
PB500116-18
PB500117-18
Nominal No. of Door Side Cable-entry plate
dimensions (mm) doors panels
Plain Transparent
Height Width Depth With mounting Without mounting Without Plain 1 entry 2 entries
(A) (B) (C) plate plate mounting plate
116
Spacial SM - SF Steel floor-standing enclosures
Selection guide
SF PB500123-18
PB500126-13
PB500477-7
PB500512-16
PB500482-10
PB500483-13
PB500124-18
PB500125-18
Nominal Plinth Mounting Intermediate Vertical uprights
dimensions (mm) plate mounting plate
Height 100 mm Height 200 mm Standard Technical
Height Width Depth Front kit Side panels, Front kit Side panels,
(A) (B) (C) (corners + 2 u. (corners + 4 u.
front panels) front panels)
1200 600 400 NSYSPF6100 NSYSPS4100 NSYSPF6200 NSYSPS4200 NSYMP126 NSYSIMP12 - NSYTVR12
600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP126 NSYSIMP12 - NSYTVR12
800 400 NSYSPF8100 NSYSPS4100 NSYSPF8200 NSYSPS4200 NSYMP128 NSYSIMP12 - NSYTVR12
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP128 NSYSIMP12 - NSYTVR12
1400 600 400 NSYSPF6100 NSYSPS4100 NSYSPF6200 NSYSPS4200 NSYMP146 NSYSIMP14 - NSYTVR14
800 400 NSYSPF8100 NSYSPS4100 NSYSPF8200 NSYSPS4200 NSYMP148 NSYSIMP14 - NSYTVR14
1600 600 600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP166 NSYSIMP16 - NSYTVR16
800 NSYSPF6100 NSYSPS8100 NSYSPF6200 NSYSPS8200 NSYMP166 NSYSIMP16 - NSYTVR16
800 600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP168 NSYSIMP16 - NSYTVR16
800 NSYSPF8100 NSYSPS8100 NSYSPF8200 NSYSPS8200 NSYMP168 NSYSIMP16 - NSYTVR16
1800 400 400 NSYSPF4100 NSYSPS4100 NSYSPF4200 NSYSPS4200 - - NSYVR18 NSYTVR18
500 NSYSPF4100 NSYSPS5100 NSYSPF4200 NSYSPS5200 - - NSYVR18 NSYTVR18
600 NSYSPF4100 NSYSPS6100 NSYSPF4200 NSYSPS6200 - - NSYVR18 NSYTVR18
600 400 NSYSPF6100 NSYSPS4100 NSYSPF6200 NSYSPS4200 NSYMP186 NSYSIMP18 NSYVR18 NSYTVR18
500 NSYSPF6100 NSYSPS5100 NSYSPF6200 NSYSPS5200 NSYMP186 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP186 NSYSIMP18 NSYVR18 NSYTVR18
800 NSYSPF6100 NSYSPS8100 NSYSPF6200 NSYSPS8200 NSYMP186 NSYSIMP18 NSYVR18 NSYTVR18
800 400 NSYSPF8100 NSYSPS4100 NSYSPF8200 NSYSPS4200 NSYMP188 NSYSIMP18 NSYVR18 NSYTVR18
500 NSYSPF8100 NSYSPS5100 NSYSPF8200 NSYSPS5200 NSYMP188 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP188 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP188 NSYSIMP18 NSYVR18 NSYTVR18
1000 400 NSYSPF10100 NSYSPS4100 NSYSPF10200 NSYSPS4200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
400 NSYSPF10100 NSYSPS4100 NSYSPF10200 NSYSPS4200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
500 NSYSPF10100 NSYSPS5100 NSYSPF10200 NSYSPS5200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP1810 NSYSIMP18 NSYVR18 NSYTVR18
1200 400 NSYSPF12100 NSYSPS4100 NSYSPF12200 NSYSPS4200 NSYMP1812 NSYSIMP18 NSYVR18 NSYTVR18
500 NSYSPF12100 NSYSPS5100 NSYSPF12200 NSYSPS5200 NSYMP1812 NSYSIMP18 NSYVR18 NSYTVR18
600 NSYSPF12100 NSYSPS6100 NSYSPF12200 NSYSPS6200 NSYMP1812 NSYSIMP18 NSYVR18 NSYTVR18
2000 300 500 NSYSPF3100 NSYSPS5100 NSYSPF3200 NSYSPS5200 - - NSYVR20 NSYTVR20
600 NSYSPF3100 NSYSPS6100 NSYSPF3200 NSYSPS6200 - - NSYVR20 NSYTVR20
800 NSYSPF3100 NSYSPS8100 NSYSPF3200 NSYSPS8200 - - NSYVR20 NSYTVR20
400 400 NSYSPF4100 NSYSPS4100 NSYSPF4200 NSYSPS4200 - - NSYVR20 NSYTVR20
500 NSYSPF4100 NSYSPS5100 NSYSPF4200 NSYSPS5200 - - NSYVR20 NSYTVR20
600 NSYSPF4100 NSYSPS6100 NSYSPF4200 NSYSPS6200 - - NSYVR20 NSYTVR20
800 NSYSPF4100 NSYSPS8100 NSYSPF4200 NSYSPS8200 - - NSYVR20 NSYTVR20
600 400 NSYSPF6100 NSYSPS4100 NSYSPF6200 NSYSPS4200 NSYMP206 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF6100 NSYSPS5100 NSYSPF6200 NSYSPS5200 NSYMP206 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP206 NSYSIMP20 NSYVR20 NSYTVR20
800 NSYSPF6100 NSYSPS8100 NSYSPF6200 NSYSPS8200 NSYMP206 NSYSIMP20 NSYVR20 NSYTVR20
800 400 NSYSPF8100 NSYSPS4100 NSYSPF8200 NSYSPS4200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF8100 NSYSPS5100 NSYSPF8200 NSYSPS5200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
800 NSYSPF8100 NSYSPS8100 NSYSPF8200 NSYSPS8200 NSYMP208 NSYSIMP20 NSYVR20 NSYTVR20
1000 400 NSYSPF10100 NSYSPS4100 NSYSPF10200 NSYSPS4200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
400 NSYSPF10100 NSYSPS4100 NSYSPF10200 NSYSPS4200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF10100 NSYSPS5100 NSYSPF10200 NSYSPS5200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF10100 NSYSPS5100 NSYSPF10200 NSYSPS5200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
800 NSYSPF10100 NSYSPS8100 NSYSPF10200 NSYSPS8200 NSYMP2010 NSYSIMP20 NSYVR20 NSYTVR20
1200 400 NSYSPF12100 NSYSPS4100 NSYSPF12200 NSYSPS4200 NSYMP2012 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF12100 NSYSPS5100 NSYSPF12200 NSYSPS5200 NSYMP2012 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF12100 NSYSPS6100 NSYSPF12200 NSYSPS6200 NSYMP2012 NSYSIMP20 NSYVR20 NSYTVR20
800 NSYSPF12100 NSYSPS8100 NSYSPF12200 NSYSPS8200 NSYMP2012 NSYSIMP20 NSYVR20 NSYTVR20
1600 400 NSYSPF16100 NSYSPS4100 NSYSPF16200 NSYSPS4200 NSYMP2016 NSYSIMP20 NSYVR20 NSYTVR20
500 NSYSPF16100 NSYSPS5100 NSYSPF16200 NSYSPS5200 NSYMP2016 NSYSIMP20 NSYVR20 NSYTVR20
600 NSYSPF16100 NSYSPS6100 NSYSPF16200 NSYSPS6200 NSYMP2016 NSYSIMP20 NSYVR20 NSYTVR20
2200 400 600 NSYSPF4100 NSYSPS6100 NSYSPF4200 NSYSPS6200 - - NSYVR22 NSYTVR22
600 600 NSYSPF6100 NSYSPS6100 NSYSPF6200 NSYSPS6200 NSYMP226 NSYSIMP22 NSYVR22 NSYTVR22
800 NSYSPF6100 NSYSPS8100 NSYSPF6200 NSYSPS8200 NSYMP226 NSYSIMP22 NSYVR22 NSYTVR22
800 600 NSYSPF8100 NSYSPS6100 NSYSPF8200 NSYSPS6200 NSYMP228 NSYSIMP22 NSYVR22 NSYTVR22
800 NSYSPF8100 NSYSPS8100 NSYSPF8200 NSYSPS8200 NSYMP228 NSYSIMP22 NSYVR22 NSYTVR22
1000 600 NSYSPF10100 NSYSPS6100 NSYSPF10200 NSYSPS6200 NSYMP2210 NSYSIMP22 NSYVR22 NSYTVR22
1200 600 NSYSPF12100 NSYSPS6100 NSYSPF12200 NSYSPS6200 NSYMP2212 NSYSIMP22 NSYVR22 NSYTVR22
800 NSYSPF12100 NSYSPS8100 NSYSPF12200 NSYSPS8200 NSYMP2212 NSYSIMP22 NSYVR22 NSYTVR22
117
Spacial SM - SF Steel floor-standing enclosures
Selection guide
PB500114-7
PB500130-7
PB500131-7
PB500477-7
PB500129-7
SF kit
PB500127-13
PB502078-17
PB500128-16
Nominal No. of Vertical Bottom Rear Side Plain door Transparent Door Trim Mounting
dimensions doors uprights frame panel panels (1) door plate plate
(mm) and top (Securit®
frame glass) (1)
with roof
Height Width Depth
(A) (B) (C)
1200 600 400 1 NSYSFV12 NSYSFC64 NSYBP126 NSY2SP124 NSYSFD126 NSYSFD126T NSYTRIM6SF NSYMP126
500 1 NSYSFV12 NSYSFC65 NSYBP126 NSY2SP125 NSYSFD126 NSYSFD126T NSYTRIM6SF NSYMP126
600 1 NSYSFV12 NSYSFC66 NSYBP126 NSY2SP126 NSYSFD126 NSYSFD126T NSYTRIM6SF NSYMP126
800 1 NSYSFV12 NSYSFC68 NSYBP126 NSY2SP128 NSYSFD126 NSYSFD126T NSYTRIM6SF NSYMP126
800 400 1 NSYSFV12 NSYSFC84 NSYBP128 NSY2SP124 NSYSFD128 NSYSFD128T NSYTRIM8SF NSYMP128
500 1 NSYSFV12 NSYSFC85 NSYBP128 NSY2SP125 NSYSFD128 NSYSFD128T NSYTRIM8SF NSYMP128
600 1 NSYSFV12 NSYSFC86 NSYBP128 NSY2SP126 NSYSFD128 NSYSFD128T NSYTRIM8SF NSYMP128
800 1 NSYSFV12 NSYSFC88 NSYBP128 NSY2SP128 NSYSFD128 NSYSFD128T NSYTRIM8SF NSYMP128
1400 600 400 1 NSYSFV14 NSYSFC64 NSYBP146 NSY2SP144 NSYSFD146 NSYSFD146T NSYTRIM6SF NSYMP146
500 1 NSYSFV14 NSYSFC65 NSYBP146 NSY2SP145 NSYSFD146 NSYSFD146T NSYTRIM6SF NSYMP146
600 1 NSYSFV14 NSYSFC66 NSYBP146 NSY2SP146 NSYSFD146 NSYSFD146T NSYTRIM6SF NSYMP146
800 1 NSYSFV14 NSYSFC68 NSYBP146 NSY2SP148 NSYSFD146 NSYSFD146T NSYTRIM6SF NSYMP146
800 400 1 NSYSFV14 NSYSFC84 NSYBP148 NSY2SP144 NSYSFD148 NSYSFD148T NSYTRIM8SF NSYMP148
500 1 NSYSFV14 NSYSFC85 NSYBP148 NSY2SP145 NSYSFD148 NSYSFD148T NSYTRIM8SF NSYMP148
600 1 NSYSFV14 NSYSFC86 NSYBP148 NSY2SP146 NSYSFD148 NSYSFD148T NSYTRIM8SF NSYMP148
800 1 NSYSFV14 NSYSFC88 NSYBP148 NSY2SP148 NSYSFD148 NSYSFD148T NSYTRIM8SF NSYMP148
1600 600 400 1 NSYSFV16 NSYSFC64 NSYBP166 NSY2SP164 NSYSFD166 NSYSFD166T NSYTRIM6SF NSYMP166
500 1 NSYSFV16 NSYSFC65 NSYBP166 NSY2SP165 NSYSFD166 NSYSFD166T NSYTRIM6SF NSYMP166
600 1 NSYSFV16 NSYSFC66 NSYBP166 NSY2SP166 NSYSFD166 NSYSFD166T NSYTRIM6SF NSYMP166
800 1 NSYSFV16 NSYSFC68 NSYBP166 NSY2SP168 NSYSFD166 NSYSFD166T NSYTRIM6SF NSYMP166
800 400 1 NSYSFV16 NSYSFC84 NSYBP168 NSY2SP164 NSYSFD168 NSYSFD168T NSYTRIM8SF NSYMP168
500 1 NSYSFV16 NSYSFC85 NSYBP168 NSY2SP165 NSYSFD168 NSYSFD168T NSYTRIM8SF NSYMP168
600 1 NSYSFV16 NSYSFC86 NSYBP168 NSY2SP166 NSYSFD168 NSYSFD168T NSYTRIM8SF NSYMP168
800 1 NSYSFV16 NSYSFC88 NSYBP168 NSY2SP168 NSYSFD168 NSYSFD168T NSYTRIM8SF NSYMP168
1800 400 400 1 NSYSFV18 NSYSFC44 NSYBP184 NSY2SP184 NSYSFD184 - NSYTRIM4SF -
500 1 NSYSFV18 NSYSFC45 NSYBP184 NSY2SP185 NSYSFD184 - NSYTRIM4SF -
600 1 NSYSFV18 NSYSFC46 NSYBP184 NSY2SP186 NSYSFD184 - NSYTRIM4SF -
800 1 NSYSFV18 NSYSFC48 NSYBP184 NSY2SP188 NSYSFD184 - NSYTRIM4SF -
600 400 1 NSYSFV18 NSYSFC64 NSYBP186 NSY2SP184 NSYSFD186 NSYSFD186T NSYTRIM6SF NSYMP186
500 1 NSYSFV18 NSYSFC65 NSYBP186 NSY2SP185 NSYSFD186 NSYSFD186T NSYTRIM6SF NSYMP186
600 1 NSYSFV18 NSYSFC66 NSYBP186 NSY2SP186 NSYSFD186 NSYSFD186T NSYTRIM6SF NSYMP186
800 1 NSYSFV18 NSYSFC68 NSYBP186 NSY2SP188 NSYSFD186 NSYSFD186T NSYTRIM6SF NSYMP186
800 400 1 NSYSFV18 NSYSFC84 NSYBP188 NSY2SP184 NSYSFD188 NSYSFD188T NSYTRIM8SF NSYMP188
500 1 NSYSFV18 NSYSFC85 NSYBP188 NSY2SP185 NSYSFD188 NSYSFD188T NSYTRIM8SF NSYMP188
600 1 NSYSFV18 NSYSFC86 NSYBP188 NSY2SP186 NSYSFD188 NSYSFD188T NSYTRIM8SF NSYMP188
600 2 NSYSFV18 NSYSFC86 NSYBP188 NSY2SP186 NSYSFD1882D - NSYTRIM8SF2D NSYMP188
800 1 NSYSFV18 NSYSFC88 NSYBP188 NSY2SP188 NSYSFD188 NSYSFD188T NSYTRIM8SF NSYMP188
800 2 NSYSFV18 NSYSFC88 NSYBP188 NSY2SP188 NSYSFD1882D - NSYTRIM8SF2D NSYMP188
1000 400 1 NSYSFV18 NSYSFC104 NSYBP1810 NSY2SP184 NSYSFD1810 NSYSFD1810T NSYTRIM10SF NSYMP1810
400 2 NSYSFV18 NSYSFC104 NSYBP1810 NSY2SP184 NSYSFD18102D - NSYTRIM10SF2D NSYMP1810
500 1 NSYSFV18 NSYSFC105 NSYBP1810 NSY2SP185 NSYSFD1810 NSYSFD1810T NSYTRIM10SF NSYMP1810
600 1 NSYSFV18 NSYSFC106 NSYBP1810 NSY2SP186 NSYSFD1810 NSYSFD1810T NSYTRIM10SF NSYMP1810
600 2 NSYSFV18 NSYSFC106 NSYBP1810 NSY2SP186 NSYSFD18102D - NSYTRIM10SF2D NSYMP1810
800 1 NSYSFV18 NSYSFC108 NSYBP1810 NSY2SP188 NSYSFD1810 NSYSFD1810T NSYTRIM10SF NSYMP1810
800 2 NSYSFV18 NSYSFC108 NSYBP1810 NSY2SP188 NSYSFD18102D - NSYTRIM10SF2D NSYMP1810
1200 400 2 NSYSFV18 NSYSFC124 NSYBP1812 NSY2SP184 NSYSFD18122D NSYSFD18122DT NSYTRIM12SF2D NSYMP1812
500 2 NSYSFV18 NSYSFC125 NSYBP1812 NSY2SP185 NSYSFD18122D NSYSFD18122DT NSYTRIM12SF2D NSYMP1812
600 2 NSYSFV18 NSYSFC126 NSYBP1812 NSY2SP186 NSYSFD18122D NSYSFD18122DT NSYTRIM12SF2D NSYMP1812
800 2 NSYSFV18 NSYSFC128 NSYBP1812 NSY2SP188 NSYSFD18122D NSYSFD18122DT NSYTRIM12SF2D NSYMP1812
(1) Hinges, locking bar catches and handle with 5-mm double-bar insert included.
118
Spacial SM - SF Steel floor-standing enclosures
Selection guide
PB500114-7
PB500130-7
PB500131-7
PB500477-7
PB500129-7
SF kit
PB500127-13
PB502078-17
PB500128-16
Nominal No. of Vertical Bottom Rear Side Plain door Transparent Door Trim Mounting
dimensions doors uprights frame panel panels (1) door plate plate
(mm) and top (Securit®
frame glass) (1)
with roof
Height Width Depth
(A) (B) (C)
2000 300 500 1 NSYSFV20 NSYSFC35 NSYBP203 NSY2SP205 NSYSFD203 - NSYTRIM3SF -
600 1 NSYSFV20 NSYSFC36 NSYBP203 NSY2SP206 NSYSFD203 - NSYTRIM3SF -
400 400 1 NSYSFV20 NSYSFC44 NSYBP204 NSY2SP204 NSYSFD204 - NSYTRIM4SF -
500 1 NSYSFV20 NSYSFC45 NSYBP204 NSY2SP205 NSYSFD204 - NSYTRIM4SF -
600 1 NSYSFV20 NSYSFC46 NSYBP204 NSY2SP206 NSYSFD204 - NSYTRIM4SF -
800 1 NSYSFV20 NSYSFC48 NSYBP204 NSY2SP208 NSYSFD204 - NSYTRIM4SF -
600 400 1 NSYSFV20 NSYSFC64 NSYBP206 NSY2SP204 NSYSFD206 NSYSFD206T NSYTRIM6SF NSYMP206
500 1 NSYSFV20 NSYSFC65 NSYBP206 NSY2SP205 NSYSFD206 NSYSFD206T NSYTRIM6SF NSYMP206
600 1 NSYSFV20 NSYSFC66 NSYBP206 NSY2SP206 NSYSFD206 NSYSFD206T NSYTRIM6SF NSYMP206
800 1 NSYSFV20 NSYSFC68 NSYBP206 NSY2SP208 NSYSFD206 NSYSFD206T NSYTRIM6SF NSYMP206
800 400 1 NSYSFV20 NSYSFC84 NSYBP208 NSY2SP204 NSYSFD208 NSYSFD208T NSYTRIM8SF NSYMP208
500 1 NSYSFV20 NSYSFC85 NSYBP208 NSY2SP205 NSYSFD208 NSYSFD208T NSYTRIM8SF NSYMP208
600 1 NSYSFV20 NSYSFC86 NSYBP208 NSY2SP206 NSYSFD208 NSYSFD208T NSYTRIM8SF NSYMP208
600 2 NSYSFV20 NSYSFC86 NSYBP208 NSY2SP206 NSYSFD2082D - NSYTRIM8SF2D NSYMP208
800 1 NSYSFV20 NSYSFC88 NSYBP208 NSY2SP208 NSYSFD208 NSYSFD208T NSYTRIM8SF NSYMP208
800 2 NSYSFV20 NSYSFC88 NSYBP208 NSY2SP208 NSYSFD2082D - NSYTRIM8SF2D NSYMP208
1000 400 1 NSYSFV20 NSYSFC104 NSYBP2010 NSY2SP204 NSYSFD2010 NSYSFD2010T NSYTRIM10SF NSYMP2010
400 2 NSYSFV20 NSYSFC104 NSYBP2010 NSY2SP204 NSYSFD20102D - NSYTRIM10SF2D NSYMP2010
500 1 NSYSFV20 NSYSFC105 NSYBP2010 NSY2SP205 NSYSFD2010 NSYSFD2010T NSYTRIM10SF NSYMP2010
500 2 NSYSFV20 NSYSFC105 NSYBP2010 NSY2SP205 NSYSFD20102D - NSYTRIM10SF2D NSYMP2010
600 1 NSYSFV20 NSYSFC106 NSYBP2010 NSY2SP206 NSYSFD2010 NSYSFD2010T NSYTRIM10SF NSYMP2010
600 2 NSYSFV20 NSYSFC106 NSYBP2010 NSY2SP206 NSYSFD20102D - NSYTRIM10SF2D NSYMP2010
800 1 NSYSFV20 NSYSFC108 NSYBP2010 NSY2SP208 NSYSFD2010 NSYSFD2010T NSYTRIM10SF NSYMP2010
800 2 NSYSFV20 NSYSFC108 NSYBP2010 NSY2SP208 NSYSFD20102D - NSYTRIM10SF2D NSYMP2010
1200 400 2 NSYSFV20 NSYSFC124 NSYBP2012 NSY2SP204 NSYSFD20122D NSYSFD20122DT NSYTRIM12SF2D NSYMP2012
500 2 NSYSFV20 NSYSFC125 NSYBP2012 NSY2SP205 NSYSFD20122D NSYSFD20122DT NSYTRIM12SF2D NSYMP2012
600 2 NSYSFV20 NSYSFC126 NSYBP2012 NSY2SP206 NSYSFD20122D NSYSFD20122DT NSYTRIM12SF2D NSYMP2012
800 2 NSYSFV20 NSYSFC128 NSYBP2012 NSY2SP208 NSYSFD20122D NSYSFD20122DT NSYTRIM12SF2D NSYMP2012
1600 400 2 NSYSFV20 NSYSFC164 NSYBP2016 NSY2SP204 NSYSFD20162D - NSYTRIM16SF2D NSYMP2016
500 2 NSYSFV20 NSYSFC165 NSYBP2016 NSY2SP205 NSYSFD20162D - NSYTRIM16SF2D NSYMP2016
600 2 NSYSFV20 NSYSFC166 NSYBP2016 NSY2SP206 NSYSFD20162D - NSYTRIM16SF2D NSYMP2016
2200 400 400 1 NSYSFV22 NSYSFC44 NSYBP224 NSY2SP224 NSYSFD224 - NSYTRIM4SF -
500 1 NSYSFV22 NSYSFC45 NSYBP224 NSY2SP225 NSYSFD224 - NSYTRIM4SF -
600 1 NSYSFV22 NSYSFC46 NSYBP224 NSY2SP226 NSYSFD224 - NSYTRIM4SF -
800 1 NSYSFV22 NSYSFC48 NSYBP224 NSY2SP228 NSYSFD224 - NSYTRIM4SF -
600 400 1 NSYSFV22 NSYSFC64 NSYBP226 NSY2SP224 NSYSFD226 NSYSFD226T NSYTRIM6SF NSYMP226
500 1 NSYSFV22 NSYSFC65 NSYBP226 NSY2SP225 NSYSFD226 NSYSFD226T NSYTRIM6SF NSYMP226
600 1 NSYSFV22 NSYSFC66 NSYBP226 NSY2SP226 NSYSFD226 NSYSFD226T NSYTRIM6SF NSYMP226
800 1 NSYSFV22 NSYSFC68 NSYBP226 NSY2SP228 NSYSFD226 NSYSFD226T NSYTRIM6SF NSYMP226
800 400 1 NSYSFV22 NSYSFC84 NSYBP228 NSY2SP224 NSYSFD228 NSYSFD228T NSYTRIM8SF NSYMP228
500 1 NSYSFV22 NSYSFC85 NSYBP228 NSY2SP225 NSYSFD228 NSYSFD228T NSYTRIM8SF NSYMP228
600 1 NSYSFV22 NSYSFC86 NSYBP228 NSY2SP226 NSYSFD228 NSYSFD228T NSYTRIM8SF NSYMP228
800 1 NSYSFV22 NSYSFC88 NSYBP228 NSY2SP228 NSYSFD228 NSYSFD228T NSYTRIM8SF NSYMP228
1000 400 1 NSYSFV22 NSYSFC104 NSYBP2210 NSY2SP224 NSYSFD2210 NSYSFD2210T NSYTRIM10SF NSYMP2210
500 1 NSYSFV22 NSYSFC105 NSYBP2210 NSY2SP225 NSYSFD2210 NSYSFD2210T NSYTRIM10SF NSYMP2210
600 1 NSYSFV22 NSYSFC106 NSYBP2210 NSY2SP226 NSYSFD2210 NSYSFD2210T NSYTRIM10SF NSYMP2210
800 1 NSYSFV22 NSYSFC108 NSYBP2210 NSY2SP228 NSYSFD2210 NSYSFD2210T NSYTRIM10SF NSYMP2210
1200 400 2 NSYSFV22 NSYSFC124 NSYBP2212 NSY2SP224 NSYSFD22122D NSYSFD22122DT NSYTRIM12SF2D NSYMP2212
500 2 NSYSFV22 NSYSFC125 NSYBP2212 NSY2SP225 NSYSFD22122D NSYSFD22122DT NSYTRIM12SF2D NSYMP2212
600 2 NSYSFV22 NSYSFC126 NSYBP2212 NSY2SP226 NSYSFD22122D NSYSFD22122DT NSYTRIM12SF2D NSYMP2212
800 2 NSYSFV22 NSYSFC128 NSYBP2212 NSY2SP228 NSYSFD22122D NSYSFD22122DT NSYTRIM12SF2D NSYMP2212
(1) Hinges, locking bar catches and handle with 5-mm double-bar insert included.
119
Spacial SM - SF Steel floor-standing enclosures
Specific accessories overview
Composition accessories
PB502427-57
PB502426-20
PB502430-29
Page 124 Page 126
Roofs Wall-mounting
PB502431-27
PB500607-29
DB300769-15
PB500330-33
PB502432-30
PB502429-6
120
Spacial SM - SF Steel floor-standing enclosures
Specific accessories overview
Installation accessories
PB502434-30
PB502435-31
PB502436-27
Page 242 Page 252
Power distribution
Busbar supports
DB404943-35
DB404943-60
Page 256
121
Spacial SM - SF Steel floor-standing enclosures
Common accessories overview
Cable management
PB502439-55
PB500966-40
PB500958-22
Page 270 Page 289
Thermal management
Heaters Ventilation Cooling units
PB502050-29
PB501044-26
PB502614-15
Page 452 Page 406 Page 435
122
Spacial SM - SF Steel floor-standing enclosures
Common accessories overview
Others
Door accessories Lighting Earthing
PB502559-25
PB501707-28
PB500217-29
Page 297 Page 292 Page 302
123
Spacial SM - SF Steel floor-standing enclosures
Accessories
Panels
SF SF SF
PB502571-30
PB502587-26
PB502524-22
124
Spacial SM - SF Steel floor-standing enclosures
Accessories
Panels
SF SF SF SF
PB502525-26
PB502588-41
PB502526-21
PB500525-22
Quick-mounting side panels Internal mounting rear panel Partition panel Trim cap
Set of 2 side panels fixed to the outside Rear panel fixed from the inside of the Partition panel for direct mounting to the Trim cap for external
of the enclosure by clipping locks. enclosure, preventing unauthorized structure, guarantees a water/dustproof mounting panels, both sides
No sealing gasket. personnel from accessing and removing protection of IP10 between enclosure and rear.
it. Normally used in public spaces. suites.
- - - Reference
- - - NSYCSP
NSY2SPQ126 NSYBPI126 -
NSY2SPQ128 - -
- - -
- - -
NSY2SPQ146 - -
NSY2SPQ148 - -
- - -
- - -
NSY2SPQ166 NSYBPI166 NSYPPS166
NSY2SPQ168 NSYBPI168 NSYPPS168
- - NSYPPS184
- - NSYPPS185
NSY2SPQ186 NSYBPI186 NSYPPS186
NSY2SPQ188 NSYBPI188 -
- NSYBPI1810 -
- NSYBPI204 NSYPPS204
- - NSYPPS205
NSY2SPQ206 NSYBPI206 NSYPPS206
NSY2SPQ208 NSYBPI208 NSYPPS208
- NSYBPI2010 -
- NSYBPI2012 -
- - -
- - -
NSY2SPQ226 NSYBPI226 NSYPPS226
NSY2SPQ228 NSYBPI228 NSYPPS228
- NSYBPI2210 -
125
Spacial SM - SF Steel floor-standing enclosures
Accessories
Coupling accessories
SF SF SF
PB500513-45
PB500531-45
PB500533-37
Characteristics Standard coupling Kit Swing 19" rack coupling Kit Reinforced coupling
PB502552-53
PB502553-53
PB502554-14
Used for joining enclosures side-to-side Used for joining enclosures equipped with It is used together with the coupling kit
or depthwide. swing 19" rack, side-to-side or depthwise. to reinforce the connection between
Mounting from the inside of the enclosure. Mounting from the inside of the enclosures. 2 enclosures when they carry heavy loads.
Mounting from the inside of the enclosures.
Material bb Flat connectors and brackets: bb Flat connectors: zinc-coated steel Zinc-coated steel
zinc-coated steel bb Sealing gasket: EPDM
bb Sealing gasket: EPDM
Supply 4 brackets, 2 flat connectors, sealing 8 flat connectors, sealing gasket and 4 reinforced connectors and mounting
gasket and mounting elements mounting elements elements
References
NSYSFBK NSYSFBK19 NSYSFBKR
126
Spacial SM - SF Steel floor-standing enclosures
Accessories
Coupling accessories
SF SF SF SM
PB500535-36
PB500536-45
PB500538-78
PB500541-38
Quick coupling Kit for coupling the previous External coupling Enclosure coupling Kit for
version with Spacial SF Spacial SM
PB502553-53
PB502568-40
PB502555-49
PB502556-35
Used for quickly joining 2 enclosures. It is used for coupling an enclosure bb Allows two enclosures to be joined bb Used for joining enclosures
Mounting from the inside of the of a previous version (OLN or Spacial by their structure. side-to-side.
enclosures. 6000) side-to-side or depthwise with bb To be used with the standard bb Enclosures fixed from the inside.
a Spacial SF enclosure. coupling kit in those cases where front
Mounting from the inside of the and back uprights are not accesibles.
enclosures. bb The mounting plate or vertical
uprights fixed to the back of the
enclosure prevent the assembly
and dismantling of the kit.
bb It can be combined with the
reinforced or the quick coupling kit.
Zinc-coated steel bb Flat connectors and spacers: bb External connectors: zinc-coated 9 x 11 sealing gasket: EPDM
zinc-coated steel steel
bb Sealing gasket: EPDM bb Sealing gasket: EPDM
4 flat links and mounting elements 6 flat connectors, sealing gasket and 4 external connectors and mounting 1 sealing gasket and mounting
mounting elements elements elements
70 90
DB300182EN
90
250
22
Ø 12.5
Door
250
45
22
45
45
127
Spacial SM - SF Steel floor-standing enclosures
Accessories
Floor
Plinth in kit form
PB502547-40
PB502548-47
PB502546-50
PB502551-47
PB502549-50
PB502550-31
The complete plinth consists of two elements, one is the front and rear kit,
determined by the length of the enclosure, and the other consists
of the side panels, which determine the depth of the enclosure.
The number of side panels required is decided according to the desired plinth
combination.
Robust design.
The modular plinth system makes it possible to reduce the number
of references in stock.
128
Spacial SM - SF Steel floor-standing enclosures
Accessories
Floor
Possibility of joining plinths
1 - The surfaces between corners are always in contact.
PB500545-35
They are joined by an M8 screw and nut, not included in the standard supply.
2 - By side panels, the M6 screws and caged nuts, not included in the standard
PB500546-35
PB500547-35
3 - Vertical plinth assembly by means of M12 screws and nuts, not included
PB500548-35
T
he two heights of corners can be combined.
M
ounting convenience and speed.
2 - Mounting from the outside of the enclosure with a M12 screw, screwing directly
PB500550-36
129
Spacial SM - SF Steel floor-standing enclosures
Accessories
Floor
Possibility of mounting the plinth to the floor
1 - Mounting from the inside of the enclosure.
PB500551-22
2 - Mounting from the outside of the enclosure, optimum point for the rigidity
PB500552-27
of the assembly.
The corners of the ends can be rotated in the event of needing to remove the side
panels of the plinth and/or to obtain access to the mounting outside the floor,
when the set is installed against the wall.
Mounting from the inside of the enclosure by means of an M12 screw, screwing
directly into the corner of the plinth.
M
ounting convenience and speed.
Mounting from the outside of the enclosure, optimum point for the rigidity
of the assembly.
130
Spacial SM - SF Steel floor-standing enclosures
Accessories
Floor
PB500557-33
PB500558-30
PB500559-28
Mounting options
Characteristics Screw M6 Caged nuts Levelling the plinth
Torx T30 M6 x 10 M6 caged nuts. The plinth allows
screws. levelling by means
of an M12 screw.
Supply 50 100 -
References
NSYSPM6 NSYCN9M625 NSYSPLK
Examples of solutions
Plinth cross rail fixed in position B
bb They are fixed to the plinth cross rails, both the universal and the quick-mounting types.
PB502564-72
A
B
A
PB502565-51
131
Spacial SM - SF Steel floor-standing enclosures
Accessories
SM SF Floor
PB502578-30
PB502583-21
PB502584-21
PB502581-18
PB502580-17
PB502582-26
PB502579-30
Characteristics Front plinth Plinth side panels Ventilated front Ventilated side Panels with
plinth panels brush
The front and rear of the They are fixed to the corner The front and rear of the They are fixed to the They allow the entry and
plinth consists of 4 corners of the plinth by 2 mounting ventilated plinth is made corner of the plinth mounting of cables
with 2 or 4 panels. screws. up of 4 corners with by mounting screws. inside the enclosure,
2 front panels. through the plinth.
Material Folded sheet steel, corner Folded sheet steel Folded sheet steel, Folded sheet steel Folded sheet steel
with a thickness of 25/10e mm corner with a thickness
of 25/10e mm
Finish Painted with epoxy-polyester Painted with epoxy-polyester Painted with epoxy- Painted with epoxy- Painted with epoxy-
resin resin polyester resin polyester resin polyester resin
Colour RAL 7022 grey RAL 7022 grey RAL 7022 grey RAL 7022 grey RAL 7022 grey
Ingress protection rating IP30 IP30 IP20 IP20 IP20
Mechanical protection IK10 IK10 IK10 IK10 IK10
rating
Supply bb Height 100 mm: 4 corners, bb Height 100 mm: 2 side bb Height 100 mm: bb Height 100 mm: bb Height 100 mm:
2 panels (front and rear), panels, 4 corner covers and 4 corners, 2 ventilated 2 ventilated side panels, 2 panels with brushes,
4 corner covers and mounting elements panels (front and rear), 4 corner covers and 4 corner covers and
mounting elements bb Height 200 mm: 4 side 4 corner covers and mounting elements mounting elements
bb Height 200 mm: 4 corners, panels (height of 100 mm, mounting elements
4 panels (2 front and 2 rear), 2 for each side), 4 corner
4 corner covers and covers and mounting
mounting elements elements
References
Width (mm) (B) 100 mm 200 mm 100 mm
30
DB300184-58
30
C-40
C-184
C-65
B-40
C+5
C
B-115.5
6
C-198
B-65
B
B+5
100
200
30
100
132
Spacial SM - SF Steel floor-standing enclosures
Accessories
Floor
PB502575-16
PB502576-12
PB502577-16
PB502574-61
PB502600-32
PB502569-33
PB502570-33
PB502572-38
PB502573-46
PB502601-32
Plinth for sets Mounting to the floor Mounting to the floor Plinth cross-rail Plinth cross rails
by mounting points of support
previous version (OLN/CMO
or Spacial 6000 and 18500)
Designed for the assembly Piece for mounting the plinth Pieces that reproduce the Support for mounting They are fixed across the width and/or
of sets of 2 to 4 Spacial SF to the floor in the event of not floor-mounting points of the a cross rail inside depth between the corners of the
enclosures, joined on a single being able to use the drill previous plinth. the plinth. plinth.
plinth. holes made in the plinth. The plinth cross-rail supports are
required for its assembly.
Folded sheet steel Steel Steel Steel Steel
bb Front plinth: 2 U-shaped 4 pieces, mounting elements 4 pieces, mounting elements not 12 pieces and 2 cross rails and mounting elements
profiles and mounting elements not supplied supplied mounting elements
bb Plinth side panel:
Height 100 mm: 2 plinths side
panels and mounting elements
80
DB300185-58
DB300187-63
80
25
25
94.5
550
114
6
Ø9
25
25
B
Ø 12.5
(1)
62.5
72.5
550
80
133
Spacial SM - SF Steel floor-standing enclosures
Accessories
Cable entries
SM SF SF SF SF
PB500115-21
PB500116-21
PB500117-21
PB500589-18
PB500581-20
Characteristics Plain cable- Plain With 1 entry With 2 entries Cable-gland plate
gland plate for connectors
Maximum compact Maximum compact Facilitates the entry of Cable entry for very Adapter plate to install cable
water/dustproof water/dustproof cables thanks to a deep enclosures entry plates for connectors,
design. design. longitudinal opening. (600 and 800 mm). see page 279. To be used
Two longitudinal together with cable-gland
openings allowing a large plates, 1 or 2 entries, adding
number of cables through. or replacing one of the parts.
Material Steel painted with Galvanised steel Galvanised steel
epoxy-polyester
resin, RAL 7035
Thicknesses 10/10e mm 15/10e mm 15/10e mm
Supply Plain plate and Plain plate and Plate with 1 entry; 1 plate with 2 entries; Plate and mounting elements
mounting elements mounting elements self-extinguishing polyurethane adhesive
polyurethane adhesive gasket with cross-section
gasket with cross-section of of 15 x 25 mm and
15 x 25 mm and mounting mounting elements
elements
Width (B) Depth (C) References No. of cuts References
300 500 - NSYEC35 NSYEC351 - - -
600 - NSYEC36 NSYEC361 -
400 400 - NSYEC44 NSYEC441 - - -
500 - NSYEC45 NSYEC451 -
600 - NSYEC64 NSYEC461 -
800 - NSYEC84 NSYEC481 -
600 300 NSYSMEC63 - - - 2 NSYDCE6
400 NSYSMEC64 NSYEC64 NSYEC641 -
500 NSYSMEC65 NSYEC65 NSYEC651 -
600 NSYSMEC66 NSYEC66 NSYEC661 NSYEC662
800 - NSYEC68 NSYEC681 NSYEC682
800 300 NSYSMEC83 - - - 3 NSYDCE8
400 NSYSMEC84 NSYEC84 NSYEC841 -
500 NSYSMEC85 NSYEC85 NSYEC851 -
600 NSYSMEC86 NSYEC86 NSYEC861 NSYEC862
800 - NSYEC88 NSYEC881 NSYEC882
1000 300 NSYSMEC103 - - - 4 NSYDCE10
400 NSYSMEC104 NSYEC104 NSYEC1041 -
500 NSYSMEC105 NSYEC105 NSYEC1051 -
600 - NSYEC106 NSYEC1061 NSYEC1062
800 - NSYEC108 NSYEC1081 NSYEC1082
1200 300 2 x NSYSMEC63 - - - 4 NSYDCE12
400 2 x NSYSMEC64 NSYEC124 NSYEC1241 -
500 2 x NSYSMEC65 NSYEC125 NSYEC1251 -
600 2 x NSYSMEC66 NSYEC126 NSYEC1261 NSYEC1262
800 - NSYEC128 NSYEC1281 NSYEC1282
1600 400 2 x NSYSMEC84 NSYEC164 NSYEC1641 - - -
500 2 x NSYSMEC85 NSYEC165 NSYEC1651 -
600 2 x NSYSMEC86 NSYEC166 NSYEC1661 NSYEC1662
B B B
DB300189-21
DB300190-27
DB300192-21
92 B-184 92 92 B-184 92
92
C-184
C
92
Enclosures of 300
and 400 mm width.
B
DB300191-21
92 B-184 92
134
Spacial SM - SF Steel floor-standing enclosures
Accessories
DB300193-100
80
50
50
50
50
C
50
50
80
1 Entry 2 Entries
800 800
Gaskets
SF SM SF SF
PB500586-24
PB502385
PB500579-22
PB500584-21
135
Spacial SM - SF Steel floor-standing enclosures
Accessories
Lifting systems
PB502528
SF SM SF
PB502529
PB502530-48
PB502545-11
Characteristics Eyebolts Lifting brackets
Maximum amount of assembled 1 2
enclosures to be lifted
Set of M12 lifting 12:12 which screw Set of M12 lifting eyebolts, fixed to Set of lifting and transport brackets, fixed to
directly into the structure of the 13:13 the enclosure by mounting nuts. the structure between two coupled enclosures,
the axis of the uprights. in the axis of the uprights.
Material Galvanised cast steel Galvanised cast steel Zinc-coated steel
Maximum load 340 kg 340 kg 500 kg
Supply 4 eyebolts 4 eyebolts and 4 mounting nuts 4 brackets and M12 screws
References
NSYSFEB NSYSMEB NSYSFELB
∅ 32
DB300195
DB300205
DB300196
55
29
54
Ø 29
Ø
60
6
M12 M12
∅ 14
49
65
100
136
Spacial SM - SF Steel floor-standing enclosures
Accessories
Lifting systems
SF
PB502531-70
Lifting bar
2 3 4 5
Steel
2000 kg (lenght 1600 mm) 3000 kg (lenght 1800 mm) 3000 kg (lenght 2400 mm) 4000 kg (lenght 3200 mm)
2 lifting bars and M12 screws
B/4 B/4
80
7
Ø 22 60
Ø 14 x 18 Ø 14 x 18
30
(3200 mm)
535 200 65 535 30
(2400 mm)
535
(1800 mm)
535 535
(1600 mm)
535 535
Shackles
DB300762-32
DB300769
Reference
NSYSFTBS
19
17
137
Spacial SM - SF Steel floor-standing enclosures
Accessories
Roof
SM SF SF SF
PB502532-22
PB502557-30
PB502544-38
PB502543-22
Characteristics Canopy Ventilated roof Ventilation elevators for roof
Provides excellent protection against splashes Roof providing natural ventilation Allows the roof to
from rainwater. for the enclosure, with IP30 protection. be raised, providing
Highly recommended for outdoor applications. Height: an extra 63 mm in relation natural ventilation.
Not compatible with the simultaneous use to the structure. They are screwed onto
of lifting elements. the structure, at the
Spacial SF: it is possible to use a single canopy roof mounting point.
with combinations of modular enclosures Material Zinc-coated steel
(example of a 1600 mm canopy with two Supply 4 elevators
coupled 800-mm enclosures).
Height (H) IP References
Material Galvanised steel Steel
(mm)
Finish Painted with polyester-epoxy resin Painted with polyester-epoxy resin
23 20 NSYRE26
Colour RAL 7035 grey RAL 7035 grey
60 10 NSYRE60
Mounting bb Spacial SF: mounting by drill holes to be -
21.8
DB300207EN-16
made in the roof of the enclosure
bb Spacial SM: mounting by drill holes already
18.9
made in the roof
Supply One canopy, drilling template and mounting One ventilated roof and four elevators
M12
elements
Width (B) Depth (C) References
16.5
(mm) (mm)
H
DB300208EN-40
2.2
B-125
72
12
C-30
C-125
C+25
B-30
138
Spacial SM - SF Steel floor-standing enclosures
Accessories
Roof
SF SF
PB500598-47
PB500597-47
PB500599-23
Characteristics FL21 cable-entry roof Cable-entry roof
Roof prepared for installing FL21 cable-entry Roof prepared for installing cable-entry plates.
plates.
Material Steel Steel
Finish Painted with epoxy-polyester resin Painted with epoxy-polyester resin
Colour RAL 7035 grey RAL 7035 grey
Supply One cut-out roof for the FL21 cable-entry plates One cut-out roof for the cable-entry plates
Dimensions (mm) Centre-to-centre No. of entries
distance (mm)
Width (B) Depth (C) D E References
600 500 285 - 1 NSYSFLR65 NSYSRCE650
600 NSYSFLR66 NSYSRCE660
800 500 195 - 2 NSYSFLR85 -
600 NSYSFLR86 -
500 220 - - NSYSRCE850
600 - NSYSRCE860
1000 500 195 290 3 NSYSFLR105 -
600 NSYSFLR106 -
500 220 285 - NSYSRCE1050
600 - NSYSRCE1060
C-30 C-30
DB300209EN-48
DB300210EN-50
Ø 9.5
D
140
232
220
E
198
105
193
B-30
B-65
E
B-30
B-65
70
135°
E
117
E
62
D
D
117 130
1.5
25 NSYAECPFLT25
198
35 NSYAECPFLT35 Ø 9.5
(1) For more information, see page 279.
62.5
130
70
140 Ø6
232
139
Spacial SM - SF Steel floor-standing enclosures
Accessories
Wall mounting
SF SM
PB502562-50
PB502563-50
Characteristics Wall mounting support
Supports for mounting the enclosure on the wall Supports for mounting the enclosure on the wall
and preventing it from turning over. and preventing it from turning over.
They cannot be used for hanging the enclosure. They are installed using the drill holes in the back
They are installed using the roof mounting screws. of the enclosure.
Enclosure fixed from the outside.
Material Zinc-coated steel Zinc-coated steel
Supply 2 supports 2 supports
References
NSYSFWFIX NSYSMWFIX
32.5 60
DB300218EN-65
DB300219EN
15 9 26.5
∅ 12
26.5
∅ 10
31
30
18
140
Spacial SM - SF Steel floor-standing enclosures
Accessories
Doors
SF SM SF
PB502571-31
PB502598-23
PB502599-30
25
B B
B - 100 B-100
min. 59 B - 300 min. 55 B-300
DB300220EN-34
DB300221EN-34
25
25
25
A-150
A-34
A-135
A - 135
A
A
19.5
19.5
141
Spacial SM - SF Steel floor-standing enclosures
Accessories
SF SM Door accessories
PB502558-25
PB502533-30
PB502559-25
Characteristics Metal document pocket PB502534-30
Plastic document pocket Folding support tray
Direct mounting on the reinforcement Attachment by adhesive tape. Adjustable horizontal support for
frame of the door. laptop computers, documents or any
Adjustable depth with a pitch of 25 mm. other element. Installation on the
reinforcement frame of the door.
Can also be installed on the door cross
rails, see page 296.
4 positions: 45°, 60°, 75° and 90°.
Material Steel Polystyrene (PS) Steel
Finish Painted with polyester-epoxy resin - Painted with epoxy-polyester resin
Colour RAL 7035 grey RAL 7035 grey (NSYDPA4: RAL9001) RAL 7035 grey
Maximum load - - 30 kg
Supply One metal document pocket and One plastic document pocket One folding support tray and mounting
mounting elements elements
Dimensions (mm) References
Doc. format A B C
A5 174 188 22 - NSYDPA5 -
A4 230 247 23 - NSYDPA4 -
A4 234 278 40 - NSYDPA44 -
A3 285 476 35 - NSYDPA3 -
Width (D)
500 - - NSYSDT5
600 NSYSDP6M - NSYSDT6
800 NSYSDP8M - NSYSDT8
D-118
DB300224-38
DB300225-28
DB300223
D-150
A
282
B C
65
142
Spacial SM - SF Steel floor-standing enclosures
Accessories
SF SM Door accessories
PB502087-33
PB502535-32
PB502561-23
PB502116-31
PB502089-31
PB502090-19
PB502078-32
Characteristics 180° hinge Door-centring caster Trim plate Customisable label
holder
Hinge with opening of 180°. Allows the door to be raised Trim plate for Spacial SF and Label holder to be placed
Intended to replace the 120° when closing. SM plain and transparent on trim plate to customise
hinges installed as standard. Direct mounting on the doors. The Schneider Electric the enclosure.
They are compatible with the reinforcement frame. logo can be placed on the left Delivered with a printable blank
transparent door and can be or on the right. label.
installed even with enclosure
suites.
Material Aluminium and zamak - UV-resistant plastic Polycarbonate (PC)
Finish Painted RAL 9005 black - - -
Mechanical protection rating - - IK09 -
Maximum load 60 kg on the door 60 kg - -
Supply 4 hinges, template for making One centring roller and 1 trim plate for single doors, 5 label holders
the drill holes and mounting mounting elements 2 trim plates for double doors
elements
References
NSYSH180 NSYSDRC - NSYCBLSF
Width (mm) No. of doors References
300 1 - - NSYTRIM3SF -
400 1 - - NSYTRIM4SF -
500 1 - - NSYTRIM5SF -
600 1 - - NSYTRIM6SF -
700 1 - - NSYTRIM7SFP -
800 1 - - NSYTRIM8SF -
2 - - NSYTRIM8SF2D -
1000 1 - - NSYTRIM10SF -
2 - - NSYTRIM10SF2D -
1200 2 - - NSYTRIM12SF2D -
1600 2 - - NSYTRIM16SF2D -
ISPA011_001-35
ISPA011_002-40
Door switch
For Spacial SF & SFX For Spacial SM
See page 295 295
Supply 1 1
References
NSYDCM20 NSYMDCM20
143
Spacial SM - SF Steel floor-standing enclosures
Accessories
Locking system
PB502429-11
DB300226EN-17
275
37.8 37
8-mm square insert with slot NSYINS8H1 2124E key lock NSYIN2124E1
6.5-mm triangular insert NSYINT61 2131A key lock NSYIN2131A1
7-mm triangular insert NSYINT71 2132A key lock NSYIN2132A1
8-mm triangular insert NSYINT81 2331A key lock NSYIN2331A1
Push button 9-mm triangular insert NSYINT91 2433A key lock NSYIN2433A1
10-mm triangular insert NSYINT101 2452E key lock NSYIN2452E1
10-mm keyless hexagonal insert NSYINH31 3113A key lock NSYIN3113A1
PB500616-18
144
Spacial SM - SF Steel floor-standing enclosures
Accessories
Locking system
PB502442-11
PB502441-8
PB502443-11
DB300227-19
DB300230EN
DB300229
279
260
343
50 37 50 37 19.6 36.4
Handles for insert types DIN, KABA, ASSA Flat escutcheon lock
Insert handle Double-insert handle
The inserts are easily and quickly mounted withoutThe double insert handle can perform the "AND" Optional flat escutcheon lock. Replaces the handle lock.
any screws and allow and "OR" functions (are supplied with the handle). Easy to change the opening direction of the door, right/
the installation of profiled DIN, KABA and ASSA - "AND" function: one insert blocks the activation left. Possibility of changing the turning direction of
locks. To install shape inserts or cylindrical barrels,
of the other insert. the insert.
it is necessary to add adapter ref. NSYLADP. - "OR" function: either insert can release
Easy to change the opening direction of the door, the handle.
right/left. Space reserved for enclosure Easy to change the opening direction of the door,
identification, 21 x 27 mm, protected by a label right/left. Space reserved for enclosure
frame. identification, 21 x 27 mm, protected by a label
frame. To install shape inserts or cylindrical
barrels, it is necessary to add adapter ref. NSYLADP.
Handle: polyamide 6 with 30 % fibreglass, RAL 9005 colour Polyamide 6 with 30 % fibreglass, RAL 9005 black
IK10 IK10
650ºC 650ºC
One handle for DIN, KABA and ASSA inserts and mounting elements (insert not included) Flat lock, shape insert, key and mounting elements
NSYSFHD2 NSYSFHD3 -
PB500627-10
PB500628-10
(1) Adapter for receiving the KABA8, KABA20 and KABA start cylinders. triangular insert
DB300228EN-35
Ø 22
Ø 17 Ø 22
Flat lock + 6.5-mm NSYSFLOCKT6
PB500630-10
triangular insert
33
24.3 24.3
40 10 female
square insert
Insert dimensions for DIN adapters. Insert dimensions for KABA adapters.
Flat lock + 8-mm NSYSFLOCKS8
PB500632-10
Ø 22
square insert
35
35
square insert
Adapter for shape inserts and cylindrical barrels References
PB500620-9
145
Spacial SM - SF Steel floor-standing enclosures
Accessories
Locking system
PB502536-12
PB502444-14
PB502542-31
PB502445-32
146
147
Stainless-steel
wall-mounting
enclosures
148
Universal Enclosures Stainless-steel wall-mounting
enclosures
Contents
Introduction 150
Characteristics 153
Dimensions 154
Accessories 155
149
Spacial S3X Stainless-steel wall-mounting
enclosures
Introduction
150
Spacial S3X Stainless-steel wall-mounting
enclosures
Introduction
The finish
The finish: 3 solutions against aggressive
environmental agents
Surface condition plays an important role in the fight against bacteria.
The lower the roughness, the fewer bacteria become incrusted.
Reduced roughness means fewer bacteria, less adherence of materials
and an impeccable finish.
To choose a finish is also to choose an appearance of the enclosures that
matches the environment of other machines and equipment.
151
Spacial S3X Stainless-steel wall-mounting
enclosures
Introduction
PB501225-31
bb Two types of steel offered as standard: 304L and
specially designed for the chemical, 316L, with Scotch-Brite® brushed finish.
oil and food and beverage industries, bb Painted or micro-beaded finish (on request).
Sealing
PB501240-60
See page 396 for details or consult our web site www.schneider-electric.com
152
Spacial S3X Stainless-steel wall-mounting
enclosures
Characteristics
PB500075-40
PB501243-28
PB501244-31
Characteristics 304L stainless-steel 316L stainless-steel
Enclosure with plain door. Enclosure with glazed door, Enclosure with plain door.
Securit® glass, 4 mm thick.
Material AISI 304L AISI 316L
Finish Scotch-Brite® brushed
Thickness 10/10e - 15/10e mm
Ingress protection rating IP66 (1 door) or IP55 (2 doors)
Mechanical protection rating IK10 IK08 IK10
Standards bb IEC 62208
Certifications bb UL 508A
bb CSA-C22.2 No. 14
bb NEMA
vv 1 door enclosure: type 1, 2, 3, 3R, 4, 4X, 5, 12, 13
vv 2 doors enclosure: type 1, 12, 12K
Installation Outdoor installation: compliant with IEC 62208 regarding type tests specified in §9.12
(resistance to ultra-violet (UV) radiation) and §9.13 (resistance to corrosion).
It is always advisable to install a canopy to avoid water stagnation on the upper part
of the enclosure
Other characteristics bb Single-piece body (cross-shaped structure). Gutter-shaped front profile
bb 4 rear studs for mounting the material
bb 2 cut-out vertical profiles on the door (from a height of 600 mm), with drill holes with a
diameter of 4.25 mm and a pitch of 25 mm for installing accessories
bb Door strengthening frame (from a height of 1000 mm), cross-section of 20 mm x 15 mm,
with drill holes with a diameter of 5 mm and a pitch of 25 mm
bb Standard lock with 3-mm double-bar lock (chrome-plated zamak)
bb 2 locking points for heights of more than 500 mm or three points for two-door enclosures
bb Stainless-steel hinges screwed to the body of the enclosure. They make it easier to remove
and invert the door. Opening angle: 120°
bb Maximum load on the door: 50 kg/m²
bb Polyurethane gasket
bb M6 x 16 screws on the door and on the body, allowing equipotential connection between
the earth connections (on request)
bb 4 holes for mounting to wall directly or with the help of mounting lugs (on request), blocked
by sealing plugs
External dimensions (mm) References
Height Width Depth No. of locks No. of doors Plain door Glazed door** Plain door
300 200 150 1 1 NSYS3X3215 - NSYS3X3215H
250 150 1 1 NSYS3X302515 - NSYS3X302515H
300 150 1 1 NSYS3X3315 - NSYS3X3315H
400 300 150 1 1 NSYS3X4315 - NSYS3X4315H
200 1 1 NSYS3X4320 NSYS3X4320T NSYS3X4320H
400 200 1 1 NSYS3X4420 - NSYS3X4420H
600 200 1 1 NSYS3X4620 - NSYS3X4620H
500 400 200 2 1 NSYS3X5420 NSYS3X5420T NSYS3X5420H
600 400 200 2 1 NSYS3X6420 NSYS3X6420T NSYS3X6420H
600 250 2 1 NSYS3X6625 - NSYS3X6625H
1000 300 1 2 NSYS3X601030 New - -
1200 300 1 2 NSYS3X601230 New - -
700 500 250 2 1 NSYS3X7525 NSYS3X7525T NSYS3X7525H
800 600 250 2 1 NSYS3X8625 NSYS3X8625T NSYS3X8625H
800 300 2 1 NSYS3X8830 - NSYS3X8830H
1000 300 1 2 NSYS3X801030 New - -
1200 300 1 2 NSYS3X801230 New - -
1000 800 300 2 1 NSYS3X10830 NSYS3X10830T NSYS3X10830H
1000 300 * 2 NSYS3X101030 - NSYS3X101030H
1200 800 300 2 1 NSYS3X12830 - NSYS3X12830H
1000 300 * 2 NSYS3X121030 - NSYS3X121030H
* Three-point closure system.
** The glazed door has no reinforcement.
153
Spacial S3X Stainless-steel wall-mounting
enclosures
Dimensions
B C B C
21 21
40
BB CC BB CC
DB300567EN-112
DB300567EN-112
External dimensions (mm) Fig. 40 2121 2121
114 114
4040
A-125A-125
A B C
A-44 A-44
4040 10 10
A-125A-125
114
A-125
300 200 150 1 B-145
A-75 A-75
A-50 A-50
A-44
A
1010 1010
A-5
83
A-125
A-75 A-75
A-44 A-44
B-44
A-50 A-50
A-5
83
250 150 1
A
B-145
B-145
25
A-75
A-50
A
A
A-5
A-5
8383
A-75
B-133B-44
A-44
B-44
300 150 1
A-50
A-5
A-5
8383 B-44
A
A
25
25
B-133
B-133
400 300 150 1 B-44
B-44
114 114
300 200 1 B-50
114
400 200 1 B-75 B - 50 800
B-50
B-50
600 200 1 B-75
B-75
B - 75
B B- 50
- 50 800
800
500 400 200 2* B B- 75
- 75
600 400 200 2
B - 76.4 B - 76.4
600 250 2 B-5 B- 5 B-5
1000 300 4 B-5
B-5
B B- 76.4
BB
- 76.4
- 5- 5
B B- 76.4
- 76.4
B B- 5- 5
1200 300 4
700 500 250 2 Fig. 1 Fig. 2
800 600 250 2
DB300567EN-112
B B C
800 300 2 40 22
1000 300 4 BB BB CC
4040 2222
114
1200 300 4
A-125A-125
10
A-125
1000 300 4 83
B-145 1010
1200 800 300 3 8383
25
A-75 A-75
A-50 A-50
B C B C
A-44 A-44
A-44 A-44
A-5
21 21
A
A
40
A-75
A-50
A-44
A-44
A-5
A-5
A
A
40
A
A
114
A-125
A-44
10 10
A-125
B-44 B-44
B-145
A-75
A-50
A
A-5
83
A-75
A-44
B-44
A-50
B-44
B-44
A-5
83 B-44
B-44
A
25
B-133
B-44
114
114
114
114
B-50 B-50
B-50 B-75 B-75
B-75 B-50
B-50 B-50
B-50
B - 50 800
B - B-75
B-75
75 B-75
B-75
B - 76.4 B - 76.4
B-5 B- 5 B-5
B-136 418.5/518.5** 372/472**
B-5 B-5
B-136
B-136 418.5/518.5**
418.5/518.5** 372/472**
372/472**
B-5
B-5 B-5
B-5
Fig. 3
B B C
DB300567EN-112
40 22
114
A-125
10
83
B-145
25
A-75
A-50
A-44
A-44
A-5
A
B-44 B-44
114
B-50 B-50
B-75 B-75
154
Spacial S3X Stainless-steel wall-mounting
enclosures
Accessories
PB500072-11
PB500100-11
PB500101-15
PB500102-15
PB500408-18
PB500136-17
External dimensions (mm) No. of modules References
Height Width Depth Mounting plate Step slides
Plain Silkscreened Microperforated Telequick Modular
300 200 150 - NSYMM32 - NSYMF32 NSYMR32 - -
250 150 - NSYMM3025 - - NSYMR3025 - -
300 150 - NSYMM33 - NSYMF33 NSYMR33 - -
400 300 150 24 NSYMM43 NSYMS43 NSYMF43 NSYMR43 NSYDLM24 -
200 24 NSYMM43 NSYMS43 NSYMF43 NSYMR43 NSYDLM24 NSYSDCR200
400 200 - NSYMM44 NSYMS44 NSYMF44 NSYMR44 - NSYSDCR200
600 200 - NSYMM64 NSYMS64 NSYMF64 NSYMR46 - NSYSDCR200
500 400 200 48 NSYMM54 NSYMS54 NSYMF54 NSYMR54 NSYDLM48 NSYSDCR200
600 400 200 48 NSYMM64 NSYMS64 NSYMF64 NSYMR64 NSYDLM48P NSYSDCR200
600 250 84 NSYMM66 NSYMS66 NSYMF66 NSYMR66 NSYDLM84P NSYSDCR250
1000 300 - NSYMM106 - NSYMF106 NSYMR106 - NSYSDCR300
1200 300 - NSYMM106 - NSYMF106 NSYMR106 - NSYSDCR300
700 500 250 66 NSYMM75 NSYMS75 NSYMF75 NSYMR75 NSYDLM66 NSYSDCR250
800 600 250 84 NSYMM86 NSYMS86 NSYMF86 NSYMR86 NSYDLM84 NSYSDCR250
800 300 - NSYMM88 - NSYMF88 NSYMR88 - NSYSDCR300
1000 300 - NSYMM108 - NSYMF108 NSYMR108 - NSYSDCR300
1200 300 - NSYMM108 - NSYMF108 NSYMR108 - NSYSDCR300
1000 800 300 234 NSYMM108 - NSYMF108 NSYMR108 NSYDLM240 NSYSDCR300
1000 300 - NSYMM1010 - NSYMF1010 NSYMR1010 - NSYSDCR300
1200 800 300 - NSYMM128 - NSYMF128 NSYMR128 - NSYSDCR300
1000 300 - NSYMM1210 - NSYMF1210 NSYMR1210 - NSYSDCR300
* Three-point closure system.
PB502484-34
PB502486-29
PB502483-28
PB502485-26
Plinth height 100 mm Plinth height 100 mm Plinth height 200 mm Plinth height 200 mm
(4 corners + front and back) (Set of 2 side panels) (4 corners + front and back) (Set of 2 side panels)
Characteristics Plinths
Material Stainless-steel, AISI 304L Stainless-steel, AISI 316L
Finish Scotch-Brite® brushing, to guarantee the durability in application where the contact with the floor increase the risk of corrosion
Installation It is necessary to order separately the plinth mounting kit (ref. NSYAPFXWM) composed by mounting hardware and drilling jig
External dimensions (mm) Plinth height 100 mm Plinth height 200 mm Plinth height 100 mm Plinth height 200 mm
Height Width Depth Kit (4 corners + Set of 2 side Kit (4 corners + Set of 2 side Kit (4 corners + Set of Kit (4 corners + Set of 2 side
(A) (B) (C) front and back) panels front and back) panels (x2) front and back) 2 side panels front and back) panels (x2)
800 800 300 NSYSPFX8100 NSYSPSX3100 NSYSPFX8200 NSYSPSX3200 NSYSPFX8100H NSYSPSX3100H NSYSPFX8200H NSYSPSX3200H
1000 800 300 NSYSPFX8100 NSYSPSX3100 NSYSPFX8200 NSYSPSX3200 NSYSPFX8100H NSYSPSX3100H NSYSPFX8200H NSYSPSX3200H
1000 300 NSYSPFX10100 NSYSPSX3100 NSYSPFX10200 NSYSPSX3200 NSYSPFX10100H NSYSPSX3100H NSYSPFX10200H NSYSPSX3200H
1200 800 300 NSYSPFX8100 NSYSPSX3100 NSYSPFX8200 NSYSPSX3200 NSYSPFX8100H NSYSPSX3100H NSYSPFX8200H NSYSPSX3200H
1000 300 NSYSPFX10100 NSYSPSX3100 NSYSPFX10200 NSYSPSX3200 NSYSPFX10100H NSYSPSX3100H NSYSPFX10200H NSYSPSX3200H
PB500024-25
PB500083-34
PB501245-18
PB500108-28
PB501706-18
PB500186-24
PB500107-14
Cable Adhesive plastic Door Lighting Clip-on nuts Blanking plate Plain mounting plate screw
entries document pocket switch for modular
chassis
Self-tapping screw
M6 x 16 M5 x 13 M5 x 16
See page 266 295 295 292 246 249 - - -
Supply 10 1 1 1 100 1 100 100 100
References
- NSYDPA44 NSYINLCRN NSYLAMCS NSYKNM6 NSYATP72MS NSYS16M6HS NSYS13M5HS NSYS16M5HS
155
Spacial S3X Stainless-steel wall-mounting
enclosures
Accessories
PB501239_1
Canopy
Material 304L stainless-steel sheet
Finish Scotch-Brite® brushed
Thickness 15/10e mm
Installation Direct mounting to the body of the enclosure
Supply Delivered with the mountings required for installation
No. of locks No. of doors For wall-mounting enclosures (mm) Dimensions (mm) References
Height Width Depth A B C D E
1 1 300 200 150 205 183 51 120 - NSYTX2015
250 150 205 183 51 120 - NSYTX2515
300 150 305 183 51 220 - NSYTX3015
400 300 150 305 183 51 220 - NSYTX3015
300 200 305 233 51 220 70 NSYTX3020
400 200 405 233 70 320 70 NSYTX4020
600 200 605 233 70 520 70 NSYTX6020
2 1 500 400 200 405 233 70 320 70 NSYTX4020
600 400 200 405 233 70 320 70 NSYTX4020
600 250 605 283 70 520 120 NSYTX6025
* 2 600 1000 300 1005 333 70 920 170 NSYTX10030
1200 300 1205 333 70 1120 120 NSYTX12030
2 1 600 1200 300 1205 333 70 1120 120 NSYTX12030
700 500 250 505 283 70 420 120 NSYTX5025
800 600 250 605 283 70 520 120 NSYTX6025
800 300 805 333 70 720 170 NSYTX8030
* 2 800 1000 300 1005 333 70 920 170 NSYTX10030
1200 300 1205 333 70 1120 120 NSYTX12030
2 1 800 1200 300 1205 333 70 1120 170 NSYTX12030
1000 800 300 805 333 70 720 170 NSYTX8030
* 2 1000 1000 300 1005 333 70 920 170 NSYTX10030
2 1 1200 800 300 805 333 70 720 170 NSYTX8030
* 2 1200 1000 300 1005 333 70 920 170 NSYTX10030
DB300577-55
B
E
53
C D
A
Wall-mounting brackets
Material 304 or 316L stainless-steel
Installation bb Wall-mounting brackets can go in horizontal or vertical position
bb Mounting from the outside
Maximum load 150 kg
Supply Set of four wall-mounting brackets
References 304L 316L
NSYPFCX NSYPFC2X
Ø13.4 9
DB300578EN-55
42.5
29
21
25
7.5 25
156
Spacial S3X Stainless-steel wall-mounting
enclosures
Accessories
PB500328-21
Inner door
bb 3-mm double-bar lock.
bb Not compatible with door retainer and door switch. Consult us.
Installation bb As standard it can be mounted an inner door and a mounting plate, on the step slides, at the same time
bb Can be mounted either on the front side of the enclosure or on step slides (not suplied with standard)
Maximum load 30 kg/m²
Supply 1 inner door
For wall-mounting enclosures (mm) Dimensions (mm) References
Height (A) Width (B) D E G H I (min.)
400 300 349 241 208 32 51 NSYPIN43
500 400 449 341 308 32 51 NSYPIN54
600 400 549 341 308 32 51 NSYPIN64
700 500 649 441 408 32 51 NSYPIN75
800 600 749 541 508 32 51 NSYPIN86*
1000 800 949 741 708 32 51 NSYPIN108*
1200 800 1149 741 708 32 52 NSYPIN128*
1 2
DB300580-43
27
40 NSYPIN inner door fixed directly to the enclosure.
A
32
23 23
min = 30
10
NSYPIN inner door fixed to the adjustable NSYSDCR
support. In this case, both the inner door and the
G C C I
E
mounting plate may be depth adjustable.
B
PB501248-16
PB501246-32 NSYSTDNCSX
NSYSTDNCSX
NSYTC6CSX
NSYTC7CSX
NSYSTDCSX
NSYTT8CSX NSYSTDCXH
NSYCL1242ECSX
NSYCL405CSX
Escutcheon
Type Double-bar lock Insert Handle lock
Standard Round Triangular Square 1242E 405 610 Screw driver
3 mm 3 mm (spare) 3 mm 8 mm 7 mm 6 mm New insert
Material Chrome-plated zamak 100 % stainless-steel Chrome-plated Polyamide 100 %
zamak stainless-
steel
Protection rating IP66
References
NSYSTDNCSX NSYSTDCSX NSYSTDCXH NSYTT8CSX NSYTC7CSX NSYTC6CSX NSYCL1242ECSX NSYCL405CSX NSYCL610CSX NSYTSML
DB300579-19
157
Stainless-steel
floor-standing
enclosures
158
Universal Enclosures Stainless-steel floor-standing
enclosures
Contents
PB500138-26
PB502731-22
Spacial SMX - SFX 160
Stainless-steel floor-standing enclosures
Introduction 160
Characteristics 161
Dimensions 162
Specific accessories 164
159
Spacial SMX - SFX Stainless-steel floor-standing
enclosures
Introduction
PB501232-36
Stainless-steel grade:
specially designed for the chemical, bb AISI 304L and 316L as standard (Spacial SMX).
oil and food and beverage industries, bb AISI 316L (on request) (Spacial SFX).
PB500958-20
bb Complete range of accessories for installation, cable
management, etc.
SMX bb 316L stainless-steel plinth: easy cable entry
(Spacial SMX).
bb 304L or 316L stainless-steel plinth: easy cable entry
(Spacial SFX).
PB500138-63
Sealing
PB500141-90
SFX Hygiene
PB501228-85
Resistance to corrosion
PB501232-36
See page 396 for details or consult our web site www.schneider-electric.com
160
Spacial SMX - SFX Stainless-steel floor-standing
enclosures
Characteristics
SMX SFX
PB500138-26
PB502731-22
Characteristics Spacial SMX Spacial SFX
Stainless-steel sheet floor-standing enclosure, bb Enclosure made up of a structure,
folded and welded. consisting of top and bottom, rear panel
and vertical profiles.
bb Single front door, with reinforcement frame.
bb Sash-bolt handle made from painted
zamak, 3 mm double bar.
Material bb 304L stainless-steel bb 304L stainless-steel
bb 316L stainless-steel bb 316L version (on request)
Finish bb Scotch-Brite® brushed finish
bb Micro-beaded and painted finishes (on request)
Thickness 15/10e mm -
Ingress protection rating IP55 according to IEC 60529
Mechanical protection rating IK10 according to IEC 62262
Standards IEC 62208
Certifications bb UL 508A bb CAN/CSA C22.2 No. 14
bb CAN/CSA C22.2 No. 14 bb NEMA:
bb NEMA: vv 1 door enclosure: type 1, 2, 3, 3R, 4, 4X,
vv 1 door enclosure: type 1, 2, 3, 3R, 4, 4X, 5, 12, 12K, 13
5, 12, 12K, 13 vv 2 doors enclosure: type 1, 12, 12K, 13
vv 2 doors enclosure: type 1, 12, 12K, 13
Installation Outdoor installation: compliant with IEC 62208 regarding type tests specified in §9.12
(resistance to ultra-violet (UV) radiation) and §9.13 (resistance to corrosion). It is always
advisable to install a canopy to avoid water stagnation on the upper part of the enclosure
Other characteristics bb Plain front door. Opening to left or right to 120° with reinforcement frame installed:
vv 3 stainless-steel hinges
vv 3-point closure with handle made from painted zamak, 5-mm double bar
vv acceptable load of 50 kg
Supply bb Welded rear panel bb Welded rear panel
bb Single-piece cable-gland plate delivered bb 4 mounting plate-supporting brackets
bb Delivered with 4 mounting plate-supporting bb Single-piece cable-gland plate with sealing
brackets gasket
Note: the panels and plinths can be installed
and the enclosures can be assembled
(on request)
External dimensions (mm) Number of front doors Stainless-steel enclosure Stainless-steel suitable enclosure
Height (A) Width (B) Depth (C) 304L 316L 304L
1400 1000 300 2 NSYSMX141030 - -
1600 800 400 1 NSYSMX16840 - -
1800 600 400 1 NSYSMX18640 - NSYSFX18640
800 400 1 NSYSMX18840 NSYSMX18840H NSYSFX18840
1200 400 2 NSYSMX181240 NSYSMX181240H NSYSFX181240
1600 400 2 NSYSMX181640 NSYSMX181640H -
2000 600 500 1 - - NSYSFX20650
800 400 1 - - NSYSFX20840
800 500 1 NSYSMX20850 - -
800 600 1 - - NSYSFX20860
1000 400 2 NSYSMX201040 NSYSMX201040H -
1000 600 2 - - NSYSFX201060
1200 500 2 NSYSMX201250 NSYSMX201250H -
1200 600 2 - - NSYSFX201260
1600 600 2 NSYSMX201660 NSYSMX201660H -
161
Spacial SMX - SFX Stainless-steel floor-standing
enclosures
Dimensions
A -70
A -70
B - 70 B - 70
A - 150
A - 150
A
M8 x 20 M8 x 20
B -150 B -150 B / 2-150 B -150 C
20
600 / 800 1000 / 1200 / 1600
B-164 B-164
C-164
C-164
F
F
E M8 x 20 E M8 x 20
B 1000 / 1200
520 520
470
436
636 636
1600
162
Spacial SMX - SFX Stainless-steel floor-standing
enclosures
Dimensions
DB300838
A -70
A -70
C - 90
B -70 B -70
A - 150
A - 150
A
B -150 B -150 B / 2-150 B -150 C
20
600 / 800 1000 / 1200 C + 31,5
720
B-164
C - 230
C-164
370
436
B -280
B 836
B-164
C - 230
C-164
163
Spacial SMX - SFX Stainless-steel floor-standing
enclosures
Specific accessories
SMX
PB502484-34
PB502486-29
PB502483-28
PB502485-26
Plinth height 100 mm Plinth height 100 mm Plinth height 200 mm Plinth height 200 mm
(4 corners + front and back) (Set of 2 side panels) (4 corners + front and back) (Set of 2 side panels)
164
Spacial SMX - SFX Stainless-steel floor-standing
enclosures
Specific accessories
SFX
PB502484-34
PB502486-29
PB502483-28
PB502485-26
Plinth height 100 mm Plinth height 100 mm Plinth height 200 mm Plinth height 200 mm
(4 corners + front and back) (Set of 2 side panels) (4 corners + front and back) (Set of 2 side panels)
165
Spacial SMX - SFX Stainless-steel floor-standing
enclosures
Specific accessories
SMX SFX
PB501258-24
PB501239-30
Characteristics Canopy
Guarantees very high protection of the enclosure when used outdoors.
Material bb 304L stainless-steel sheet
bb Other types of stainless-steel, contact us
Finish bb Scotch-Brite® brushed
bb Other finishes, contact us
Thickness 15/10e mm
Installation It is fixed in the same holes as the eyebolt.
Delivered with mountings. Other dimensions and canopy for sets, contact us
External dimensions (mm) Top-mounting
Height Width Depth
(A) (B) (C)
1400 1000 300 NSYSCX10030 -
1600 800 400 NSYSCX8040 -
1800 600 400 NSYSCX6040 NSYSCX6040
800 400 NSYSCX8040 NSYSCX8040
1200 400 NSYSCX12040 NSYSCX12040
1600 400 NSYSCX16040 -
2000 600 500 - NSYSCX6050
800 400 - NSYSCX8040
800 500 NSYSCX8050 -
800 600 - NSYSCX8060
1000 400 NSYSCX10040 -
1000 600 - NSYSCX10060
1200 500 NSYSCX12050 -
1200 600 - NSYSCX12060
1600 600 NSYSCX16060 -
PB501259-SE-17
PB501260-SE-19
Material bb The enclosures are delivered as standard with handle made from painted zamak, 5 mm double bar
(1242E, 405E, 455E, 6.5 mm triangle available)
bb Large range of standard inserts available
Supply 1 pack 1 pack 1 pack 1 pack 1 pack 1 pack 1 pack 1 pack 1 pack 1 pack
References
NSYMCSX NSYTDB5ME NSYTC6ME NSYTC7ME NSYTC8ME NSYTT6ME NSYTT8ME NSYBCME NSYTCL405ME NSYTCL610ME
ISPA011_001-35
ISPA011_002-40
Door switch
For Spacial SFX
See page 295
Supply 1
Reference
NSYDCM20
166
Spacial SMX - SFX Stainless-steel floor-standing
enclosures
Specific accessories
PB500122-8
PB500122-8
PB500482-9
PB500483-13
PB500482-9
PB500483
Characteristics Side panels Plain mounting plate Uprights vertical
bb Side panels including a - - - -
polyurethane sealing gasket.
bb Their special design guarantees
the protection of the door gasket.
Material bb 304L stainless-steel sheet - - - -
External dimensions (mm) Standard Technical Standard Technical
Height Width Depth
(A) (B) (C)
1400 1000 300 - NSYMP1410 - - NSYTVR14 - -
1600 800 400 - NSYMP168 - - NSYTVR16 - -
1800 600 400 NSY2SPX184 NSYMP186 NSYMP186 NSYVR18 NSYTVR18 NSYVR18 NSYVR18
800 400 NSY2SPX184 NSYMP188 NSYMP188 NSYVR18 NSYTVR18 NSYVR18 NSYVR18
1200 400 NSY2SPX184 NSYMP1812 NSYMP1812 NSYVR18 NSYTVR18 NSYVR18 NSYVR18
1600 400 - NSYMP1816 - NSYVR18 NSYTVR18 - -
2000 600 500 NSY2SPX205 - NSYMP206 - - NSYVR20 NSYVR20
800 400 NSY2SPX204 - NSYMP208 - - NSYVR20 NSYVR20
800 500 NSY2SPX205 NSYMP208 - NSYVR20 NSYTVR20 - -
800 600 NSY2SPX206 - NSYMP208 - - NSYVR20 NSYVR20
1000 400 - NSYMP2010 - NSYVR20 NSYTVR20 - -
1000 600 NSY2SPX206 - NSYMP2010 - - NSYVR20 NSYVR20
1200 500 - NSYMP2012 - NSYVR20 NSYTVR20 - -
1200 600 NSY2SPX206 - NSYMP2012 - - NSYVR20 NSYVR20
1600 600 - NSYMP2016 - NSYVR20 NSYTVR20 - -
PB501257-19
PB501262-35
PB501242-24
PB500220-19
PB502972-20
167
Insulating
boxes
168
Universal Enclosures Insulating boxes
Contents
PB500091-20
Insulating industrial boxes
Introduction 170
Characteristics 171
Selection guide 172
Dimensions 174
Specific accessories 178
Common accessories 183
Introduction 184
Characteristics 185
Selection guide 186
Dimensions 188
Accessories 189
PB501325SE-20
PB501325-20
hy change?
W ow can I obtain RAL 7032
H
To harmonize the Schneider Electric enclosures?
Universal enclosures offer. Consult us.
Answer to customer requests and to
the the market trends. ill the new RAL 7035 colour offer
W
the same properties as RAL 7032?
hat happen with the part numbers
W Yes, all mechanical properties will be
(references)? the same. The light reflexion is
Every product that has changed in colour even improved.
also has a changed part umber. The
letter "G" has been added at the end on
reference. Example:
RAL 7032 RAL 7035
NSYPLM43 NSYPLM43G
169
Thalassa TBS - TBP Insulating industrial boxes
Introduction
PB500271-32
3 methods of mounting the box to its support.
- ABS for conventional applications
(IK07) with the usual constraints,
- polycarbonate for enhanced impact
resistance (IK08) and for outdoor
applications or applications directly
exposed to UV, Easy to use
PB502073-72
Only one tool is required: a flat screwdriver.
- polycarbonate certified UL,
- IP55 rating for all ranges,
- Protection against electrical impacts
Class II.
Smart
PB500091
See page 396 for details or consult our web site www.schneider-electric.com
170
Thalassa TBS - TBP Insulating industrial boxes
Characteristics
PB500090-16
PB500091-24
PB500250-15
PB500252-22
Characteristics Universal boxes with IP66 Equipped button boxes, ABS boxes for buttons,
in ABS with IP54 to be equipped
bb Boxes that can be coupled (exactly the same dimensions) with kit ref. 13934.
bb Locks from box size of 116 x 116 x 62 mm:
vv cover locking by 4 plastic captive screws with coarse thread outside the sealed area,
vv plumbable lock.
bb Locks from box size of 138 x 93 x 72 mm:
vv the standard screws (flat screwdriver) can be replaced with other standardised screws (page 178).
bb The 4 "legs" of the cover ensure its robustness and perfect support during customisation operations.
bb Adaptable hinges on all the 20- and 40-mm covers (page 180).
Material bb ABS boxes: bb ABS boxes:
vv glow wire resistance: 650°C according vv glow wire resistance: 650°C according to IEC 60695-2-11
to IEC 60695-2-11 vv usage temperature: -25°C...+60°C
vv usage temperature: -25°C...+60°C vv installation temperature: -15 C...+40°C
vv installation temperature: -15 C...+40°C
bb Polycarbonate boxes:
vv glow wire resistance: 960°C
vv usage temperature: -25°C...+80°C
vv installation temperature: -15°C...+60°C
Colour bb Body: RAL 7035 grey
bb Cover: RAL 7035 grey or tinted transparent
Ingress protection rating IP66 IP54 -
Mechanical protection rating ABS: IK07 (2J) according to IEC 62262 ABS: IK07 (2J) according to IEC 62262
Polycarbonate: IK08 (2J) according
to IEC 62262
Standards IEC 62208
Certifications bb IEC 62208 certified by TÜV bb IEC 62208 certified by TÜV
bb SEMKO, DEMKO bb SEMKO, DEMKO
bb UL 508A: polycarbonate range bb UL 508A: polycarbonate range
bb Product Environmental Profile bb Product Environmental Profile
bb NEMA 4.4X according to NEMA 250 bb NEMA 4.4X according to NEMA 250 and UL 50/50E
bb Class II according to IEC 61140 bb Class II according to IEC 61140
bb Self-extinguishing: UL 94-V0
Installation Mounting the box
bb Outside the sealed sensitive volume by the 4 chimneys in the corners from box size of 138 x 93 x 72 mm
bb Through the rear of the box by 2 or 4 elongated holes to be perforated
bb With mounting brackets from box size of 116 x 116 x 62 mm (ref. NSYAEFTB)
Outdoor installation: compliant with IEC 62208 regarding type tests specified in §9.12 (resistance to ultra-violet (UV) radiation)
and §9.13 (resistance to corrosion). It is always advisable to install a canopy to avoid water stagnation on the upper part
of the enclosure
Equipment installation
bb Studs for mounting the equipment in the body and the cover of the box by means of a Ø 4-mm self-tapping screw
(ref. NSYAMFSTB, screw Ø 4 x 10 mm with Pozidriv and slotted head)
bb Option of installing rails, plates (page 181) or other types of supports (card, etc.)
bb Spacers and stand-offs to be installed on the studs, for adjusting the height of the equipment
Other characteristics bb Thermal dissipation: bb Thermal dissipation:
vv use a suitable calculation method vv use a suitable calculation method according to IEC 60890
according to IEC 60890 vv anti-condensation valves available as an accessory, prevent the build-up
vv anti-condensation valves available of moisture inside the box
as an accessory, prevent the build-up
of moisture inside the box
171
Thalassa TBS - TBP Insulating industrial boxes
Selection guide
PB500090
PB500091-32
Overall external Overall internal Body Cover Minor Cover Universal boxes with IP66
dimensions dimensions pack. screw
(mm) (mm) (mm) (mm) ABS IP66 IK07 PC-UL IP66 IK08
Height Width Depth Height Width Depth Opaque Transparent Opaque Transparent
cover cover cover cover
74 74 54 65 65 47 37 10 5 Metal NSYTBS775 - NSYTBP775 -
89 89 54 80 80 47 37 10 5 Metal NSYTBS885 - NSYTBP885 -
116 74 62 105 65 55 45 10 5 Metal NSYTBS1176 - NSYTBP1176 -
94 105 65 85 45 40 3 Metal NSYTBS1179H - - -
116 62 105 105 55 45 10 5 Plastic NSYTBS11116 - NSYTBP11116 -
133 105 105 125 45 80 2 Plastic NSYTBS111113H - - -
138 93 72 125 80 65 45 20 2 Plastic NSYTBS1397 NSYTBS1397T NSYTBP1397 NSYTBP1397T
164 121 87 150 105 80 60 20 2 Plastic NSYTBS16128 NSYTBS16128T NSYTBP16128 NSYTBP16128T
192 121 87 175 105 80 60 20 2 Plastic NSYTBS19128 NSYTBS19128T NSYTBP19128 NSYTBP19128T
105 175 105 100 60 40 2 Plastic NSYTBS191210H NSYTBS191210HT NSYTBP191210H NSYTBP191210HT
164 87 175 150 80 60 20 1 Plastic NSYTBS19168 NSYTBS19168T NSYTBP19168 NSYTBP19168T
105 175 150 100 60 40 1 Plastic NSYTBS191610H NSYTBS191610HT NSYTBP191610H NSYTBP191610HT
241 194 87 225 175 80 60 20 1 Plastic NSYTBS24198 NSYTBS24198T NSYTBP24198 NSYTBP24198T
107 225 175 100 80 20 1 Plastic NSYTBS241910 NSYTBS241910T NSYTBP241910 NSYTBP241910T
107 225 175 100 60 40 1 Plastic NSYTBS241910H NSYTBS241910HT NSYTBP241910H NSYTBP241910HT
127 225 175 120 80 40 1 Plastic NSYTBS241912H NSYTBS241912HT NSYTBP241912H NSYTBP241912HT
291 241 88 275 225 80 60 20 1 Plastic NSYTBS29248 NSYTBS29248T NSYTBP29248 NSYTBP29248T
128 275 225 120 100 20 1 Plastic NSYTBS292412 NSYTBS292412T NSYTBP292412 NSYTBP292412T
128 275 225 120 60 60 1 Plastic NSYTBS292412H NSYTBS292412HT NSYTBP292412H NSYTBP292412HT
168 275 225 160 100 60 1 Plastic NSYTBS292416H NSYTBS292416HT NSYTBP292416H NSYTBP292416HT
341 291 128 325 275 120 100 20 1 Plastic NSYTBS342912 NSYTBS342912T NSYTBP342912 NSYTBP342912T
168 325 275 160 100 60 1 Plastic NSYTBS342916H NSYTBS342916HT NSYTBP342916H NSYTBP342916HT
172
Thalassa TBS - TBP Insulating industrial boxes
Selection guide
PB500242-17
PB500250-17
PB500253-22
PB500252-22
PB500249-17
Overall external Overall internal Body Cover Minor Boxes equipped with IP54 ABS ABS button boxes,
dimensions (mm) dimensions (mm) (mm) (mm) pack. buttons to be equipped
Height Width Depth Height Width Depth Function References No. of Cover References
holes
74 74 83 - - - - - 1 Emergency switching off XALEK1702 (1) - - -
116 74 62 105 65 55 45 10 5 - - 2 Grey XALE2
62 105 65 55 45 10 5 - - 3 Grey XALE3
75 - - - - - 1 Start / stop XALE2141 - - -
75 - - - - - 1 Up / down / stop XALE3255 - - -
(1) Ref. XALEK1702 houses an emergency switching off palm button with mechanical locking according to standards IEC 60364-5-53 and 60947-5-5.
Button description
bb Emergency switching off function with a red, Ø 40 mm, "turn to unlock"
palm button.
bb Start / Stop function with 2 push buttons.
bb Up / Down / Stop function with 3 push buttons.
bb Technical features of the switches:
vv "NC" switch with positive opening manoeuvre according to
IEC 60947-5-1 appendix K,
vv mechanical durability of the emergency switch: 0.1 million cycles,
vv mechanical durability of the "NC" and "NO" switches: 5 million cycles,
vv protection against short circuits: 10 A.
Function Type
"NO" "NC" "C / O" Type of push
Emergency 1 1 - Latching, red
switching off
Start/stop
Start 1 - - Flush, green
Stop - 1 - Projecting, red
Up / down / stop
Up - - 1 Flush, black
Down - - 1 Flush, white
Stop - 1 - Projecting, red
DB300033
DB300033
DB300033
173
Thalassa TBS - TBP Insulating industrial boxes
Dimensions
DB300034EN-69
Ø4 Ø4
Ø4
30
30
25
25
30
30
30
25
30
2 47.2 2 Ø47.2
16 Ø 16
41 41 2 47.2 Ø 16
53.5 53.5 41
49.5 49.5 53.5
73.5 73.5 49.5
73.5
DB300035EN-73
19
19
19
56
56
56
Ø4 Ø4 Ø4
19
19
19
Ø 20 Ø 20 Ø 20
64.5 64.5 2 2 19 19 64.5 2 19
7 7 7
80 80 47.2 47.2 80 47.2
88.5 88.5 53.5 53.5 88.5 53.5
107 DB300037EN-25
DB300036EN-79
Ø4 Ø4 Ø4
19
19
19
115.5
115.5
19115.5
91.5
91.5
91.5
107
107
50
80
50
80
50
80
19
19
Ø 20 Ø 20 Ø 20
2 2 2
49.5 49.5 7 7 19 19 87.4
49.5 7 19
65 65 55.2 55.2 65
93.6 55.2
73.5 73.5 61.5 61.5 73.5 61.5
DB300039EN-40
DB300038EN-125
DB300038EN-125
Ø 44
Ø ØØ44
Ø 20
Ø 20 ØØ20
20
105.6
54
54
115
50
50
87
87
54
50
54
87
50
87
Ø20
Ø 20 ØØ20
20
Ø 44
Ø ØØ44
77
77 22 77 88 77
77
2
133.22 77 88
107 55.5 107 55.5
55.5 92
92 92
92
107 55.5 107
115 62
62 115
115 62
62
115
DB300040EN-128
DB300040EN-128
5.4
5.4
5.4
Ø 20 Ø 20
Ø 20
125
125
116
116
138
138
104
104
125
116
138
106
106
50
50
87
87
104
87
87
106
50
87
64
64
87
74
74
64
74
Ø 20 Ø 20
Ø 20
2.1 2.12.1
42 7
65
9 42 42 29 7 7 65 65 9 9 29 29
80 80 80 59 59 59
93 72 93 93 72 72
174
Thalassa TBS - TBP Insulating industrial boxes
Dimensions
4.
2 Ø4
Ø4
5.4 Ø 20
141
113
130
100
131
150
164
130
89
50
95
Ø 20
70 2.1 9
7 80
107
121 87
Ø4
Ø4 Ø4
5.4
Ø 20
178.5
158.5
160
192
170
136
130
100
118
158
128
Ø 20
2.1 9 2.1
70 7 7 9 98
107 80 100
121 87 107
Ø4 ØØ44 Ø4
(60 + 20) (60 + 40)
Ø 20 ØØ20
20 Ø 20
178.5
158.5
178.5
178.5
158.5
158.5
178.5
158.5
193
170
193
136
193
130
170
100
170
136
136
130
130
100
100
193
170
136
130
100
Ø 20 ØØ20
20 Ø 20
2.1 2.1
2.1 2.1
113 113
113 113 7 77 9 99 7 2.1 7 2.1
2.1
9 77 9 2.1 799 9
150 150
150 150 80 80
80 80 100 100
100 100
164 164
164 164 87 87
87 87 107 107
107 107
130 130
130 130 133 133
133 133
100 100
100 100 93 93
93 93
158
128
158
158
128
128
160
160
160
118
118
118
158
128
160
118
175
Thalassa TBS - TBP Insulating industrial boxes
Dimensions
Ø4
241
189
225
185
150
125
120
Ø 20
45
218
207
177
208
166
45
Ø 20
Ø4
Ø 20
205
291
275
255
235
200
125
Ø 20
207 209
177 170
DB300044EN-176
257
227
217
258
176
Thalassa TBS - TBP Insulating industrial boxes
Dimensions
Ø4
Ø 20
341
325
305
285
250
200
125
Ø 20
2.1 9
2.1 9 7
240 7 120 160
275 128 168
291
257
227 259
220
90
277
308
307
267
90
177
Thalassa TBS - TBP Insulating industrial boxes
Specific accessories
PB500260-42
PB500259
DB300048-25
Characteristics Coupling kit Sealed anti-condensation valve
The coupling kit allows you to join several boxes with dimensions Controls the pressure to avoid condensation following
from 138 x 93 mm. an internal temperature increase.
Applications
Protection of equipment for luminaires, industrial control,
transportation, pumps, etc.
Material Polystyrene 650° PA6-V2, acrylic co-polymer membrane, water and oil
repellent
Ingress protection rating IP66 IP68
Installation The kit is installed by drilling a hole with Ø 32 mm in the boxes The valve is installed by drilling a hole with Ø 12 mm
to be coupled in the box
Usage temperature - -40...+105°C
Supply The kit consists of 2 linking parts, nuts and seals 10 valves, nuts and seals
Drill Ø Minor pack. Reference Permeability (1) Pressure References
difference (2)
32 mm 1 13934 - - -
M12 10 - 16 litres/h ΔP < 1 bar NSYCAG12LPH1
M12 10 - 120 litres/h ΔP < 0.1 bar NSYCAG12LPH2
DB300049-63
M32
M32
77
178
Thalassa TBS - TBP Insulating industrial boxes
Specific accessories
Cover accessories
PB500275
PB500277-14
PB500276-23
DB300063-12
Triangle Double bar
179
Thalassa TBS - TBP Insulating industrial boxes
Specific accessories
Hinges
PB500273-60
PB500274-46
PB500271-32
PB500272-32
Characteristics Set of 2 hinges Set of 4 mounting brackets
bb The hinges can be adapted to all covers with a height bb Plastic mounting brackets for installation on boxes with
of 20 and 40 mm with dimensions from 138 x 93 mm. dimensions from 116 x 116 mm.
bb The hinge allows the lid to open fully to 200°. bb Option of vertical or horizontal installation.
Ingress protection rating IP66 IP66
Installation bb The hinge allows an opening angle > 200° Installation by a single screw at the last moment, with the box
bb The hinge does not require any machining and is installed closed and equipped
easily even with the box already equipped
Maximum load Hinged cover: 10 kg/m2 bb Body: 30 kg/m2
bb Cover: 10 kg/m2
Minor pack. 1 1
Supply The hinges (2 per set) are delivered with the mountings 4 lugs + screws
Height of the lid (mm) References Reference
20 NSYAEDH20TB NSYAEFTB
40 NSYAEDH40TB
A+37
DB300057-37
DB300056EN-108
A+17.5
A+17.5
A
DB300062-32
A-22.5 A-22.5
A-6.5
DB300061-32
A+37
A+17.5
A+17.5
A
11 7
A-22.5 A-22.5
A-6.5
180
Thalassa TBS - TBP Insulating industrial boxes
Specific accessories
Installation accessories
PB500256-24
PB500257-24
Characteristics Mounting plates
Mounting plates made to adapt to all usage scenarios.
5.5
5.
5
9.5
B
25
181
Thalassa TBS - TBP Insulating industrial boxes
Specific accessories
Installation accessories
PB500280-15
PB500279-14
PB500282-17
PB500283-17
PB500281-22
Characteristics Rails
Symmetric DIN rails.
bb A 15 x 5-mm rail is provided for the compact terminal blocks.
bb To raise the rail, use stand-offs ref. NSYAMFET154TB, NSYAMFET204TB, NSYAMFET304TB
and the screw NSYAMFESTB.
Installation Mounting of the rails with Ø 4-mm self-tapping screws, (not included), Pozidrive and slotted head, ref. NSYAMFSTB
Supply Supplied without screws (except for the 15 x 5 mm rails)
For boxes with height or width 15 x 5 mm 35 x 7.5 mm 35 x 15 mm
(mm) Minor pack. References Minor pack. References Minor pack. References
105 10 NSYAMRD11155TB 10 NSYAMRD11357TB - -
150 10 NSYAMRD16155TB 10 NSYAMRD16357TB - -
175 10 NSYAMRD19155TB 10 NSYAMRD19357TB - -
225 10 NSYAMRD24155TB 10 NSYAMRD24357TB 10 NSYAMRD243515TB
275 10 NSYAMRD29155TB 10 NSYAMRD29357TB 10 NSYAMRD293515TB
325 10 NSYAMRD34155TB 10 NSYAMRD34357TB 10 NSYAMRD343515TB
7.5 15 7.5 15 7.5 15
DB300067EN-70
DB300067EN-70
DB300067EN-70
9 9 9
5.5
5.5
5.5
5.5 5.5 5.5
1 1 1.51 1 1.51 1 1.5
1 1 1
16
16
16
10.5
10.5
10.5
32
32
32
35
35
35
15
15
15
35
35
35
27
27
27
27
27
27
10.5
10.5
10.5
15 15 15
Accessories Pack of 100 screws
Ø 4 x 10 mm NSYAMFSTB
PB500278-35
Screw NSYAMFESTB.
Stand-offs or spacer.
DB300066-35
10
H
H = 15, 20, 30
10
182
Thalassa TBS - TBP Insulating industrial boxes
Common accessories
PB500975-15
PB500976-11
PB500099-9
PB500267-10
PB500266-52
Spare Parts
Accessories bag
PB502997-39
Reference
NSYTBPASBS
183
Thalassa PLS Insulating modular boxes
Introduction
Protection
PB500213-134
bb IP65.
bb Gasket between body and cover.
bb IK09.
bb Insulation Class II.
Easy
PB501290
See page 396 for details or consult our web site www.schneider-electric.com
184
Thalassa PLS Insulating modular boxes
Characteristics
IPLS005_001-17
Class II
PB500094-16
PB500092-16
PB501296-23
PB500095-14
PB500095-14
PB500093-16
185
Thalassa PLS Insulating modular boxes
Selection guide
PB500094-16
PB500092-16
PB500095-14
PB500095-14
PB500093-16
PB501292-24
PB501293-24
PB501293-24
186
Thalassa PLS Insulating modular boxes
IPLS005_001-17 Selection guide
PB501296-23
Insulating modular boxes with modular distribution chassis Modular distribution chassis
No. of 18 mm modules No. of rows Weight* (kg) References References
12 1 1.7 NSYPLS1827DLS12 NSYDLS12
24 2 2.5 NSYPLS2727DLS24 NSYDLS24
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
24 2 2.7 NSYPLS3627DLS24 NSYDLS242
36 3 2.8 NSYPLS3627DLS36 NSYDLS36
- -
- - - - -
- - - - -
- - - - -
48 4 3.8 NSYPLS5427DLS48 NSYDLS48
- - - - -
- - - - -
- - - - -
PB500072-11
PB500102-15
PB500151-17
PB500103-11
PB501295-23
PB501294-24
187
Thalassa PLS Insulating modular boxes
Dimensions
NSYPLS●●●1827
180 NSYPLS●●●3654●
540 A
180
180
110 540
540
180 138 45 70 200 540 200 138 45 95
DB300601EN-146
DB300602EN-90
110
110 138 45 70
70 200200 200 138 45 95
110 138
180 45138 45 200 70
540
200 200 138 45
138 9545 95
2 180 2 540 1
180
110 138 45 200 540
2
2 110
110
138
138
45
45 200 2 70
200 2 70
70 1
1
200
200
200
138
138
138
45
45
45
95
95
95
2 1 2
249
249
200
270
249
200
270
249
249
1 3 2.3
2 1 2
249
200
270
249249
2 1 2
249
1159 3 3 2.3
200
270
249
290
360
339
1
339
1 2.3
290
360
212 3 122.22.3 1 2
339
200200
270270
339
249249
159 2 6 3
290
360
339
339
159 2 6 3
249
122.2
12 122.2
290
360
339
339
249
4 15912 2 6 3 2.7
290290
360360
339339
339339
1 3 2 6 3
200
270
12 122.2
249
2.3
249
200
270
519
249
4 1 3 2.3 2.7
2.7
4
200
270
249
290
360
339
6 3
339
159 122.2
12 122.2 2
290
360
339
519
339
12 2 6 3
122.2
159 159 12 2.73 3
290
12 122.2
360
3 3
339
339
159 4
159 12 122.2 2 5 6 4 519 3 12 122.2
2.7 3 3
4 5 4 519 2.7
4
159 5
260 4
5 260 519 4 12 122.2 3 3
159 260 260 12 122.2 3 3 B
270 260 12 122.2 3 3
270 159
NSYPLS●●●2727●
270
200 270 138 45 95 5 260
5
260 4
260
4
200 138 45 95 5
260 4
260
200 138 45 95 260 260
DB300602EN-90
200
270 138 45 95 260 260
1
270
270
200 138 45 95 NSYPLS●●●5454●
1
1 200 138 45 95 540
200
1 138 45 95 540
249
249
200 540
70 200 540 138 45 95
200
270
249
4 2
200
270
249
2.3
249
1
249249
249
249
4 249 24 12.3
200200
270270
249249
12 200
12 122.22 3* 2 2 3* 2 2 70 200 138 45 95
249
249
249
200
270
249
3
3 4 2 2.3 1 1 2 70
200 200
2 138 45 95
200
270
249
4 249 3 2 2.3
249 249 12 122.2 2 3* 2
2 3*
200
260
2 8 3
200
260
249 249 12 122.2 2 3* 2 1 2
200
1 2
260
249 3 12 122.2 8 3
70 200
249
260
3 8 1 3 2
200200
260260
3 8 3 A - B: Internal view of the
249
249 8 3
200
260
200
260
8 3 corners of the polyester
519
540
249
519
540
70 70200
260
70
8 3
519
540
360
70
519
540
519519
540540
360
NSYPLS●●●2736●
360
290
290 360 138
138
45
45
95
95
2.7
2.7 ref. NSYTEX5 for M5 screws.
519
540
290 138 45 95
519
540
2.7
70
260
95 7 4
260
290 138 45
70
2.7
200
360
519
540
360 7 519 4
260
20020070
200
7 4
260
200
1 360 7
519 4
260260
290
290 138
138 45
45 95
95 519 519 12 122.2 2.73
2.7 3
1
1 290 138 45 95 12 122.2 3
2.73 3
1 7 12 122.2
4 3
260
249
6 12 122.2 3 3
200
7 5 519 4
249
260
200
200
270
249
4 2 1 2.3 6 7 5 519 4
200
270
249
249
260
200
6 5 519
249
1
249249
249
249
4 339 4 2
200200
122.2
270270
249249
12 2 2.3 2 3* 2 260
260 260 12 122.2 3 3
339
339 2 3* 2 6 260
6
260 5
260
249
3 4 122.22.3 2
200
270
249
6 5
249
200
270
249
3 4
3 2 2.3 260 260
200
270
249
339 4 339
3
339 2 2.3
12 122.2
12 122.2 2
2 3*
3* 2
2
260
260
260
260
339
339 339
3
339
3 12 122.2 2 3* 2 NSYPLS●●●3672●
3 720
339
339 720
720
339 290 70 290
720 138 95
360 290
290 70
70 290
290 138
138 95
95
360
360 290 70
720 290 138 95
290 360 138 45 720
NSYPLS●●●3636
290
290 138
138 45
45138 1 290
290 2720
70 290 138 95
290
360
360
45 1
1 290
1 270
2 70
290
290
2
138
138
95
95
1 360
290
290 138 45
1
1 138 45 1 2
290
1 138 45 1 2
290
360
339
339
290
360
1 3 2
339
339
6
290
360
339
339
1 6 3 2.7
290
360
339
339
1 6 3
290290
360360
339339
339339
6 699 3
290
360
339
339
2.7
290
360
2 1
339
339
339
339
339
6 3
339
290
360
339
339
4 2 2 2.7
290
360
339
699
339
290290
360360
339339
339339
339 4 2.7 6 12 3
122.2 3.5
290
122.2
360
12 3.5
339
339
2.7 5 6 4 12 3 2.7
122.2
2.7 3.5
339 4 2 122.2 2.7
3 699
339 339 12
290
360
339
339
5 4
4699 2.7
290
360
339
339
4 122 5
12 2 122.2 3 5 350 350
699 4 12 122.2 3.5
290
122.2 12 122.2
360
3
339
339
3 4 2.7
2.7 3 12 122.2 3.5
3 339
339 2.7 5 350
350 350
350 4 12 122.2 3.5
3 3
339 12 122.2 3 350
5 350
4
339 12 122.2 3 5 4
339 122.2 3
339 3
339
3
3
12
NSYPLS●●●5472●350
350
350
350
350
350
339
339
339 720
290 720
720
70 290 138 95
290 70 720
290 138 95
290 70
290 290
70
720 290 138 95138 95
540 720
540 1 290 720
2
200 540
NSYPLS●●●2754●
200
70
70
200 540 138 45 95
95 1
1 290 270
270 290
290 138
138 95
95
200 70 200200
200 540
70 200
138
138 45
45
138 95
45 95 290
1 70 290
2 138 95
200
540
260
200
260
1 200 2 540
70 200 138 45 95 8 1 3 2
200
1 3 2
260
95 8 3
70 200
1 2 70 8 1 2
200200
260260
1 200
1 200
2 138 45 95 8 3
249
249
200
270
249
8 3
200
200
270
260
249
6 3
249
200
260
1 22.7 8 3
519
540
249
200
270
249
519
540
6 1 3 2
249249
70 70200
260
2.7
70
519
200
270
8 3
249
6 3 22.7
200200
270270
249249
519
540
519
519
540
200 70
519
519519
540540
249
249
6
249
249
519
540
5 4 2.7
70
260
6 3 2.7 7 4
260
70
519 12
200
260 260 7 4
260
200
5
260
5 4
260
4 12 699 12 122.2 42.7
2.7
699 12
5 4 7 12 122.2
122.2
4 42.7
4122.2
260
6 5 12 4
200
7 4
260
260 260
200
260 260 6
350 6 5
699
350 5 12 122.2 4
350 350 12 122.2 4
350 6
350 350 5
350 12 122.2 4
6 5
* Thickness of 30/10e mm for the polyester cover. 6
350 5
350
350 350
350 350
188
Thalassa PLS Insulating modular boxes
Accessories
Mounting
PB501297
PB501312-39
PB501298
Characteristics Wall-mounting brackets Post-mounting device Plastic carrying handle
Material Passivated Stainless-steel - Plastic
zinc-coated steel
Supply Set of 4 lugs and mountings Contains all the elements required for -
mounting on a post
References For installation References Reference
on a surface with
dimensions (mm)
NSYPF27N NSYPF27X 270 NSYFSP27270 NSYATM27
360 NSYFSP27360
540 NSYFSP27540
DB300607
DB300603
44
M6 M6
108
130
Coupling
PB501300-33
PB501299-22
PB501302
PB501301-34
(1) References by unit. Order by multiples of 10 units (10, 20, 30, etc.).
(2) M6 x 8 screw with cylindrical head.
189
Thalassa PLS Insulating modular boxes
Accessories
Locking
PB501305-20
PB501308-29
PB501310-37
With slotted head.
PB501306-20
PB501309-30
PB501311-31
With wings.
PB501307-20
Other
PB501303-37
PB501314-34
PB501304-34
PB501315-19
190
Thalassa PLS Insulating modular boxes
Accessories
Examples of assembly
NSYPLS5427DLS48
DB300608-71
PB501313-119
NSYBE27
All the boxes can be joined by their lateral surfaces, using the
coupling frames NSYUM••• or NSYUCC•••, and the joining
and mounting pieces NSYPS2C27 and NSYPS4C27.
NSYTL27270
NSYUM27270 NSYTL27270
Drill holes
DB300605-48
191
Insulating
wall-mounting
enclosures
192
Universal Enclosures Insulating wall-mounting
enclosures
Contents
PB500147-14
Thalassa PLM 194
Insulating wall-mounting enclosures
Introduction 194
Characteristics 195
Dimensions 196
PB500076-54
PB501325SE-20
PB501325-20
hy change?
W ow can I obtain RAL 7032
H
To harmonize the Schneider Electric enclosures?
Universal enclosures offer. Consult us.
Answer to customer requests and to
the the market trends. ill the new RAL 7035 colour offer
W
the same properties as RAL 7032?
hat happen with the part numbers
W Yes, all mechanical properties will be
(references)? the same. The light reflexion is
Every product that have changed in even improved.
colour have also changed the part umber.
It is done just adding a letter "G" at the
end on reference. Example:
RAL 7032 RAL 7035
NSYPLM43 NSYPLM43G
193
Thalassa PLM Insulating wall-mounting
enclosures
Introduction
P129702-32
High resistance to corrosion in harsh environments,
enclosure maintaining its mechanical properties and insulation.
- made from polyester reinforced
with fibreglass, moulded by hot
compression.
- Degree of protection IP66,
- Impact resistance IK10 for the Easy
PB501327-40
bb Door easily reversible by turning it over.
plain doors and surfaces and bb Opening to 120° or 180°.
IK08 for the glazed doors of bb Easy machining with no corrosion.
bb Lightness.
the polyester versions, bb Polyamide hinge pin, easily removable and captive.
- UL certification and NEMA
classification 4x and 13 for the
polyester wall-mounting enclosures, Smart
PB501325-95
See page 396 for details or consult our web site www.schneider-electric.com
194
Thalassa PLM Insulating wall-mounting
enclosures
Characteristics
PB500144-22
PB500145-14
PB500146-14
PB500147-14
PB501265-14
PB501264-14
Class II
External Wall-mounting enclosures with plain door and mounting plate (4)
dimensions (mm)
Height Width Depth Plain Bakelite Plain Bakelite Plain Bakelite
308 255 160 - - NSYPLM3025P NSYPLM3025B - -
310 215 160 NSYPLM32P NSYPLM32B - - - -
430 330 200 - - - - NSYPLM43P NSYPLM43B
530 430 200 - - - - NSYPLM54P NSYPLM54B
647 436 250 - - - - NSYPLM64P NSYPLM64B
747 536 300 - - - - NSYPLM75P NSYPLM75B
847 636 300 - - - - NSYPLM86P NSYPLM86B
1056 852 350 - - - - - NSYPLM108B
(4) Not mounted.
195
Thalassa PLM Insulating wall-mounting
enclosures
Dimensions
DB300611EN-100
8
Ø8 M8
129
144
170 121
125
186
310
225
275
239
125 152
2.3
270
225
247
334
215 5 160
7
131.5
220
103
14
168.5
214
220
308
275
225
286
255
315
222
53 125 54 20
5 160
275
338
15
Ø8 M8
373 294 NSYPLM54T
O
251 NSYPLM54TV H
E
J
U
252 NSYPLM64TV
563 394 NSYPLM75T V
G
M
A
L
352 NSYPLM75TV
L Y
663 494 NSYPLM86T
452 NSYPLM86TV
D
B 5 C
External fixing with lugs (mm) References
X'
15
Vertical Horizontal
Y'
X Y X’ Y’
490 225 355 360 NSYPLM43
590 325 455 460 NSYPLM54
690 330 555 465 NSYPLM64
790 430 655 565 NSYPLM75
890 530 755 665 NSYPLM86
1090 750 955 885 NSYPLM108
196
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories overview
Composition accessories
PB501348-68
PB501747-15
PB501333-24
Page 199 Page 200
PB500159-23
PB501335-40
Page 201 Page 201 Page 201
PB500163-40
PB501343-32
197
Thalassa PLM Insulating wall-mounting
enclosures
Common accessories overview
Cable management
Cable management Cable holding Cable ducting
PB502492-29
PB500966-40
PB500958-22
Page 270 Page 270 Page 289
Thermal management
Heaters Ventilation Thermal control
PB502050-29
PB501044-26
PB501162-19
Page 452 Page 406 Page 459
PB502859-18
198
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
Base accessories
PB501747-26
PB501746-25
Accessories Cable supporting cross-rail Kit for IP54 Feet for partially buried
installation
The lateral sides of the plinths are provided Makes it possible to obtain IP54 for the Allows the partially buried installation of
with bosses for attaching cross-rails with plinth and the plinth-enclosure coupling. plinths before completion of the floor.
cut-out profiles, for supporting cables. The plinths are attached by four feet
The reference of the cross-rail includes all with a standard length of 750 mm.
the elements required for assembly. Possibility of horizontal adjustment
of the plinth.
The reference includes a kit made up
of four feet and mountings.
For plinth Cross-rail Reference Reference
references
NSYZM253 NSYAC280 NSYAEPZM NSYAEBFZ
NSYZM263 NSYAC360
NSYZM283 NSYAC600
199
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
Mounting
PB501333-39
PB500156-55
PB501334-88
PB501331-25
PB500155-12
PB501332-25
NSYPFPLM32G NSYPFPLMG NSYPFXPLM
130
200
165
251
355 165
DB300615-30
800
405 200
200
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
PB500158-37
PB500159-33
Characteristics Coupling frame Cable-gland plates
Allows the lateral coupling of 2 enclosures. Dimensions: 435 x 185 mm and
635 x 185 mm.
Material Polyester frame Polyester
Colour RAL 7032 grey* RAL 7032 grey*
Ingress protection rating A built-in sealing gasket guarantees a -
protection rating of IP66
Supply Delivered with mountings -
External Entry For wall-mounting enclosure References
dimensions (mm)
435 x 185 x 15 398 x 148 NSYPLM75 and NSYPLM86 NSYBUPLM NSYTLA4420
635 x 185 x 15 598 x 148 NSYPLM108 NSYBU108PLM NSYTLA6420
* RAL 7035 from 2016.
Door
PB501335-52
201
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
Locking system
PB501336-33
Options to transform versions NSYPLM●●V, with retractable handle and 3-point closure
Transformation of the standard insert (barrel for key 1242E, ref. NSYTL1242EME) for other
shape inserts or barrels according to the following table.
Name References
5 mm double bar NSYTDB5ME
6 mm male square NSYTC6ME
7 mm male square NSYTC7ME
8 mm male square NSYTC8ME
6.5 mm male triangle NSYTT6ME
8 mm male triangle NSYTT8ME
Barrel and key 405 NSYTCL405ME
Reinforced key and barrel NSYTLRME
JIS key and barrel NSYTLJISME
Manual NSYTMME
202
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
Locking system
DB300617-23
Padlocking accessories
Padlocking system Padlocking system Padlocking system
positioned around the positioned around to block access to the
rectangular escutcheon the long rectangular retractable handle, for the
of the enclosures with a escutcheon of the versions NSYPLM●●V or
height of ≤ 847 mm to enclosures ref. optionally for enclosures
block access to the lock; NSYPLM108G/TG, to ref. NSYPLM108G/TG,
for a Ø 9 mm padlock. block access to the lock; for a Ø 9 mm padlock.
for Ø 9 mm padlock.
References
NSYKPLM NSYBCPL NSYBCME
203
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
Mounting accessories
PB500149-42
PB501342-42
PB500163-36
Characteristics Step slides Plastic nuts for rail mounting 35 mm symmetrical DIN rails
Kit allowing depth adjustment with a pitch They slide directly into the notches, with a They are fixed to the rear of the enclosure
of 12.5 mm, and the mountings required pitch of 25 mm, which are located on the without uprights, with a pitch of 25 mm for
for the installation. rear of the enclosures, except enclosure the notches on the rear of the enclosure,
Incompatible with the modular ref. NSYPLM3025/T. They allow direct with the help of direct-mounting nuts ref.
distribution chassis. mounting of symmetrical DIN rails by NSYTCSPLM or NSYTCSM6PLM.
self-tapping screws. Option of raising
the rails with an M6 spacer using a plastic
nut containing an M6 nut.
Material Galvanised steel - Treated steel
Supply 4 step slides with brackets References by unit. Order by multiples References by unit. Order by multiples
of 20 units (20, 40, 60, etc.) of 2 units (2, 4, 6, etc.)
For wall-mounting enclosure Depth adjustment References Name References Rail length References
(mm) (mm) (mm)
Width Depth A B
- - - - - Plastic nut with NSYTCSPLM - -
self- tapping screw
- - - - - Plastic nut containing NSYTCSM6PLM - -
an M6 metal nut
215 - - - - - - 180 NSYCS200PLM
330 - - - - - - 280 NSYCS300PLM
430 / 436 - - - - - - 380 NSYCS400PLM
536 - - - - - - 480 NSYCS500PLM
636 - - - - - - 580 NSYCS600PLM
852 - - - - - - 795 NSYCS800PLM
- 200 156 94 NSYDPLM200 - - - -
- 250 200 100 NSYDPLM250 - - - -
- 300 250 100 NSYDPLM300 - - - -
- 350 306 106 NSYDPLM350 - - - -
DB300619-42
B
A
204
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
Diverse
PB500191-25
PB500164-28
PB501343-44
PB500162-17
NSYTEX8PLM NSYTEX6 NSYTEX5
Characteristics Mounting inserts Ventilation Water drain Renovation and anti-graffiti paint
louvres* plug
Expanding inserts for addition to the M6 They can be For drainage of Paint kit with 2 components Solvent for
bosses of the enclosure, the M5 or M6 positioned inside condensation (base 80 % + hardener 20 %), diluting the
bosses of the door and the M8 bosses of the the wall-mounting water. specially designed for polyester paint and
external rear part of the enclosure. enclosures with It is placed in enclosures, for their renovation cleaning the
heights of 430 to the Ø 8.5 mm** and/or as prevention to allow utensils.
846 mm, allowing housing at the easy removal of graffiti.
ventilation through bottom of the
the channels of enclosure.
the enclosure.
Colour - - - RAL 7032 grey -
Ingress protection rating - The IP on the rear IP53 (IEC 60529 - -
of the enclosures cat. 2)
is IP44
Supply References by unit. Order by multiples References by References by The 1 kg The 5 kg 500 g
of 8 units (8, 16, 24, etc.). M5 and M6 inserts unit. Order by unit. Order by reference reference
to be ordered in multiples of 20 multiples of 2 units multiples of includes 1 pot includes 1 pot
(2, 4, 6, etc.) 10 units (10, 20, with 800 g of with 4 kg of
30, etc.) base paint base paint
and 200 g of and 1 kg of
hardener hardener
(It is enough to (It is enough to
paint a surface paint a surface
of around 5 m2) of around
25 m2)
Insert For wall-mounting References Reference Reference References
size enclosure
M5 NSYPLM43G and NSYTEX5 NSYCAG35LP NSYVEA9 NSYAUPG1 NSYAUPG5 NSYAUPGS
NSYPLM54G
M6 NSYPLM64G and NSYTEX6
NSYPLM108G
M8 For the rear of NSYTEX8PLM
the enclosure
* Ventilation louvres, airing devices with filters, fans and thermal adjustment accessories, see ClimaSys section.
** 8.2 mm for wall-mounting enclosures NSYPLM32, NSYPLM32T, NSYPLM32P and NSYPLM32B.
205
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
PLM
* Minimum depth 200 mm.
206
Thalassa PLM Insulating wall-mounting
enclosures
Specific accessories
PB500152
PB501346-47
PB501345-47
Characteristics Plain front panels for Dinimel Mounting plate for Dinimel Modular distribution
DLA chassis DLA chassis chassis
bb Front panel for non-modular device bb Mounting plate for mounting non- For mounting modular devices on two
protection, on one row. modular devices, on one row. rows of nine 18-mm modules.
bb To be ordered in multiples of 2. bb To be ordered in multiples of 2.
Material Self-extinguishing insulating Galvanised-steel bb Chassis: metal
bb Protective plate: insulating material
Colour RAL 7032 grey* - -
For installing on the chassis Width (mm) References Width (mm) References Reference
NSYDLA24 256 NSYCTL300DLA - - -
NSYDLA48 and NSYDLA48P 356 NSYCTL400DLA 315 NSYPMP400DLA -
NSYDLA66 and NSYDLA88 456 NSYCTL500DLA 415 NSYPMP500DLA -
NSYDLA84 and NSYDLA112 555 NSYCTL600DLA 514 NSYPMP600DLA -
NSYDLA234 755 NSYCTL800DLA 714 NSYPMP800DLA -
For enclosure
NSYPLM3025G/TG - - - - NSYDLPLM18
* RAL 7035 from 2016.
207
Insulating
floor-standing
enclosures
208
Universal Enclosures Insulating floor-standing
enclosures
Contents
PB501353-19
Polyester floor-standing enclosures
Introduction 210
Characteristics 211
Dimensions 212
Selection guide 214
Specific accessories overview 216
Common accessories overview 217
Specific accessories 218
PB501325SE-20
PB501325-20
hy change?
W ow can I obtain RAL 7032
H
To harmonize the Schneider Electric enclosures?
Universal enclosures offer. Consult us.
Answer to customer requests and to
the the market trends. ill the new RAL 7035 colour offer
W
the same properties as RAL 7032?
hat happen with the part numbers
W Yes, all mechanical properties will be
(references)? the same. The light reflexion is
Every product that have changed in even improved.
colour have also changed the part umber.
It is done just adding a letter "G" at the
end on reference. Example:
RAL 7032 RAL 7035
NSYPLM43 NSYPLM43G
209
Thalassa PLA Polyester floor-standing
New dimensions
enclosures
2000 mm height Introduction
620 mm depth
Easy
PB501358-33
PLAZ version
Open bottom
PB501360-32
Smart
PB501361-32
PLAZT version
Easy
PB501363-32
Resistant
PB501364-32
See page 396 for details or consult our web site www.schneider-electric.com
210
Thalassa PLA Polyester floor-standing
enclosures
Characteristics
PB501353-20
PB500215-35
PB501359-21
PB500216-19
PB501362
Characteristics PLA version PLAT version PLAZ version PLAZT version
Completely sealed Enclosure with ventilated Enclosure with plinth-type Enclosure with plinth-type
enclosure canopy open bottom open bottom and ventilated
canopy
bb Enclosure obtained bb Enclosure obtained bb Enclosure obtained bb Enclosure obtained
by assembling: by assembling: by assembling: by assembling:
vv 1 sealed top part, vv 1 open top part with canopy, vv 1 sealed top part, vv 1 open top part with canopy,
vv 1 sealed bottom part, vv 1 sealed bottom part, vv 1 plinth-type open bottom vv 1 plinth-type open bottom
vv 2 side parts, vv 2 side parts, part, part,
vv 1 or 2 rear panels vv 1 or 2 rear panels vv 2 side parts, vv 2 side parts,
(according to width), (according to width), vv 1 or 2 rear panels vv 1 or 2 rear panels
vv 1 or 2 doors (according vv 1 or 2 doors (according (according to width), (according to width),
to width). to width). vv 1 or 2 doors (according vv 1 or 2 doors (according
bb Locking system with bb Locking system with handle to width). to width).
escutcheon and 5-mm with a 5-mm double-bar insert bb Locking system with handle bb Locking system with handle
double-bar insert, included block, included in the standard with a 5 mm double-bar insert with a 5 mm double-bar insert
in the standard supply. Other supply. Other blocks with block, included in the standard block. Other blocks with
inserts or locks with handles inserts or barrels and keys supply. Other blocks with inserts or barrels and keys
optionally available. optionally available. inserts or barrels and keys optionally available.
bb Door opening to 120°. bb Door opening to 120°. optionally available. bb Door opening to 180°.
bb Door opening to 120°. bb Anti-lever system to prevent
forcing of the door.
Material Polyester reinforced with fibreglass
Finish Moulded by hot compression: the pieces have an excellent finish on both sides and can include numerous bosses
for accommodating inserts and mounting or cable management accessories
Colour RAL 7032 grey*
Ingress protection rating IP65 according to IEC 60529 bb IP44 according to IP54 according to IEC 60529 bb IP44 according to
IEC 60529 IEC 60529
bb IP54 with 1 or 2 internal bb IP54 with 1 or 2 internal
grilles, ref. NSYCAG125LPF, grilles, ref. NSYCAG125LPF,
to be ordered separately to be ordered separately
Mechanical protection rating bb IK10 (20 joules) plain door - IEC62262
bb IK08 (5 joules) glazed door
Insulation Class II according to IEC 60950-1
Certifications bb UL 508A/CAN-C22.2 No. 14 bb 62208
vv single door: types bb Environment: the factory complies with ISO 14 001 (Environmental management)
1, 2, 3, 3R, 3S, 4, 4X, 5, 12 and ISO 50 001 (Energy management system)
and 13
vv double door: types
1, 2, 12 and 13
bb Marine
bb IEC 62208
bb Environment: the factory
complies with ISO 14 001
(Environmental management
and ISO 50 001 (Energy
management system)
Installation bb Indoor use only. For outdoor bb Outdoor or indoor installation: compliant with IEC 62208 regarding type tests specified in
use, must install a canopy §9.12 (resistance to ultra-violet (UV) radiation) and §9.13 (resistance to corrosion). It is always
advisable to install a canopy to avoid water stagnation on the upper part of the enclosure
bb Direct mounting to the floor or by means of a plinth with a bb The open bottom part forms a 60 mm plinth which is fixed
height to the floor directly or by means of an optional mounting frame,
of 60 mm, as an option, see page 220 see page 222, or else it is installed on a semi-embedded
bb Possibility of mounting on a semi-embedded plinth, page 220 plinth, see page 222
bb Optional wall-mounting brackets
Options Anti-posting door upon request
* RAL 7035 from 2016.
211
Thalassa PLA Polyester floor-standing
enclosures
Dimensions
Sealed enclosure
PLA
DB300624EN-155
(2) (2)
A–95
A–95
A–95
(2)
A–95
(2) (2)
A–95
A–95
A–253
A–253
A–150 (1)
A–150 (1)
A–150 (1)
A–150 (1)
A–150 (1)
A–150 (1)
260
260
B–215
260
A
C–8 C–8
A
A
C–8
C–140C–140
C–140
37.5 37.5 75 75
37.5 75
A–255
A–255
A–255
25
25
25
25
25
25
B–150B–150
(1) (1) B–150B–150
(1) (1) 28.5 28.5
28.5 28.5
B–150 (1) B–150 (1) 28.5 28.5
21 21
C 21 C C
38
38
38
(2) (2)
A–95
(2)
A–95
A–95
A–95
(2)
A–95
(2) (2)
A–95
A–150 (1)
A–150 (1)
A–150 (1)
A+38
A+38
A–150 (1)
A+38
(2) (2)
260
260
260
C–8 C–8
C–8
C–140 C–140
C–140
37.5 37.5 75 75
37.5 75 A–255
A–255
A–255
25
25
25
25
25
25
B–150 (1) B–150 (1) B–150 (1) B–150 (1) 28.5 28.5 28.5 28.5
B–150 (1) B–150 (1) 28.5 28.5
C 21 C C 21
21
B–120B–120 B–120B–120
(3) (3)
DB300626-107
M8 M8
37
M8
/ 28(5)
M8
C–125(3)
C–125(3)
(2)
C–140
37
23 / 28(5)
C–125(3)
C–125(3)
(2)
C–140
40
C–140
(2) (2) 40
C–140
(2) (2)
25
25
25
25
B–295B–295
23
212
Thalassa PLA Polyester floor-standing
enclosures
Dimensions
A–95
A–95
A–95
A–95
A–95
A–95
(2) (2) (2) (2) (2) (2)
A–150 (1)
260 (1)
A–150 (1)
A–150 (1)
A–150 (1)
A–150 (1)
(2) (2) (2) (2) (2) (2)
A–150
260
260
A+55
A+55
A+55
C–8 C–8 C–8
A–255
A–255
A–255
25
25
25
25
25
25
55
55
55
B–150 (1) B–150 (1)
B–150 (1) B–150 (1) B–150 (1)
B–150 (1) 28.5 28.5 28.5 28.5
28.5 28.5
C 21 C C 21 21
DB300816EN
C-42
38
(2) (2) (2) (2)
(1)
A-95
A-95
A-95
(1)
A-95
(1) (1) (1)
(4) (4) (4) (4)
B-95 B-95 B-95 B-95 C-170
A–95
A–95
(
A-200
(2) (2)
A–95
A–95
(2)
A–253
(2)
A–253
(4) (4)
(4) (1) (1) (4)
B–95 B–95 C–
B–95 B–95
(1) (1)
A-150
A-150
A-150
A-150
A+55
A–150 (1) 260
C-8
A–150 (1)
A–150 (1)
A–150 (1)
25
25
25
25
55
25
25
C–160 (3)
C–160 (3)
M8
37
23/28 (5)
M8
23/28C–68
C–68
M8 40
37
(5)
M8
C–68
C–68
40
B–81 B–81
B–81 B–81
(1) 4 bosses with M8 inserts and studs for direct mounting of mounting plates.
(2) Bosses designed to accommodate M8 inserts, ref. NSYTEX8. They are placed:
– On the back of the enclosure, from the height of 1000 mm. They allow the mounting of partial mounting plates and assorted equipment.
– On the top and bottom parts of the enclosure. They are used for mounting the step slides, an internal door, 19" chassis, etc.
(3) Dimensions for mounting on the floor or on a plinth.
(4) Entry dimensions, door open.
(5) Dimension of 28 mm for enclosures with heights of more than 1000 mm (height after the installation of the plain mounting plates with reinforcement foldings).
(6) With a width of 1250 mm in standard supply, 500-mm door on the left and 750-mm door on the right.
213
Thalassa PLA Polyester floor-standing
enclosures
Selection guide
PB500168-21
PB500165-22
PB500166-23
Dimensions (mm) Completely sealed enclosures, IP65 Enclosures with plinth-type
open bottom part, IP54
References of enclosures with door
Height (A) Width (B) Depth (C) N° of doors Plain Glazed Plain
500 500 320 1 NSYPLA553 NSYPLA553T NSYPLAZ553
420 1 NSYPLA554 NSYPLA554T NSYPLAZ554
750 320 1 NSYPLA573 NSYPLA573T NSYPLAZ573
420 1 NSYPLA574 NSYPLA574T NSYPLAZ574
1000 320 2 NSYPLA5103 NSYPLA5103T NSYPLAZ5103
420 2 NSYPLA5104 NSYPLA5104T NSYPLAZ5104
1250 320 2 NSYPLA5123 NSYPLA5123T NSYPLAZ5123
420 2 NSYPLA5124 NSYPLA5124T NSYPLAZ5124
750 500 320 1 NSYPLA753 NSYPLA753T NSYPLAZ753
420 1 NSYPLA754 NSYPLA754T NSYPLAZ754
750 320 1 NSYPLA773 NSYPLA773T NSYPLAZ773
420 1 NSYPLA774 NSYPLA774T NSYPLAZ774
1000 320 2 NSYPLA7103 NSYPLA7103T NSYPLAZ7103
420 2 NSYPLA7104 NSYPLA7104T NSYPLAZ7104
1250 320 2 NSYPLA7123 NSYPLA7123T NSYPLAZ7123
420 2 NSYPLA7124 NSYPLA7124T NSYPLAZ7124
1000 500 320 1 NSYPLA1053 NSYPLA1053T NSYPLAZ1053
420 1 NSYPLA1054 NSYPLA1054T NSYPLAZ1054
750 320 1 NSYPLA1073 NSYPLA1073T NSYPLAZ1073
420 1 NSYPLA1074 NSYPLA1074T NSYPLAZ1074
1000 320 2 NSYPLA10103 NSYPLA10103T NSYPLAZ10103
420 2 NSYPLA10104 NSYPLA10104T NSYPLAZ10104
1250 320 2 NSYPLA10123 NSYPLA10123T NSYPLAZ10123
420 2 NSYPLA10124 NSYPLA10124T NSYPLAZ10124
1250 500 320 1 NSYPLA1253 NSYPLA1253T NSYPLAZ1253
420 1 NSYPLA1254 NSYPLA1254T NSYPLAZ1254
750 320 1 NSYPLA1273 NSYPLA1273T NSYPLAZ1273
420 1 NSYPLA1274 NSYPLA1274T NSYPLAZ1274
1000 320 2 NSYPLA12103 NSYPLA12103T NSYPLAZ12103
420 2 NSYPLA12104 NSYPLA12104T NSYPLAZ12104
1250 320 2 NSYPLA12123 NSYPLA12123T NSYPLAZ12123
420 2 NSYPLA12124 NSYPLA12124T NSYPLAZ12124
1500 500 320 1 NSYPLA1553 NSYPLA1553T NSYPLAZ1553
420 1 NSYPLA1554 NSYPLA1554T NSYPLAZ1554
750 320 1 NSYPLA1573 NSYPLA1573T NSYPLAZ1573
420 1 NSYPLA1574 NSYPLA1574T NSYPLAZ1574
1000 320 2 NSYPLA15103 NSYPLA15103T NSYPLAZ15103
420 2 NSYPLA15104 NSYPLA15104T NSYPLAZ15104
1250 320 2 NSYPLA15123 NSYPLA15123T NSYPLAZ15123
420 2 NSYPLA15124 NSYPLA15124T NSYPLAZ15124
214
Thalassa PLA Polyester floor-standing
enclosures
Selection guide
IP44
PLAT PLAZT
PB500170-21
PB500172-19
Dimensions (mm) Enclosures with ventilated Enclosures with plinth-type
canopy, IP44 open bottom part and ventilated
canopy, IP44
References of enclosures with door
Height (A) Width (B) Depth (C) N° of doors Plain Plain
500 500 320 1 NSYPLAT553 NSYPLAZT553
420 1 NSYPLAT554 NSYPLAZT554
750 320 1 NSYPLAT573 NSYPLAZT573
420 1 NSYPLAT574 NSYPLAZT574
1000 320 2 NSYPLAT5103 NSYPLAZT5103
420 2 NSYPLAT5104 NSYPLAZT5104
1250 320 2 NSYPLAT5123 NSYPLAZT5123
420 2 NSYPLAT5124 NSYPLAZT5124
750 500 320 1 NSYPLAT753 NSYPLAZT753
420 1 NSYPLAT754 NSYPLAZT754
750 320 1 NSYPLAT773 NSYPLAZT773
420 1 NSYPLAT774 NSYPLAZT774
1000 320 2 NSYPLAT7103 NSYPLAZT7103
420 2 NSYPLAT7104 NSYPLAZT7104
1250 320 2 NSYPLAT7123 NSYPLAZT7123
420 2 NSYPLAT7124 NSYPLAZT7124
1000 500 320 1 NSYPLAT1053 NSYPLAZT1053
420 1 NSYPLAT1054 NSYPLAZT1054
750 320 1 NSYPLAT1073 NSYPLAZT1073
420 1 NSYPLAT1074 NSYPLAZT1074
1000 320 2 NSYPLAT10103 NSYPLAZT10103
420 2 NSYPLAT10104 NSYPLAZT10104
1250 320 2 NSYPLAT10123 NSYPLAZT10123
420 2 NSYPLAT10124 NSYPLAZT10124
1250 500 320 1 NSYPLAT1253 NSYPLAZT1253
420 1 NSYPLAT1254 NSYPLAZT1254
750 320 1 NSYPLAT1273 NSYPLAZT1273
420 1 NSYPLAT1274 NSYPLAZT1274
1000 320 2 NSYPLAT12103 NSYPLAZT12103
420 2 NSYPLAT12104 NSYPLAZT12104
1250 320 2 NSYPLAT12123 NSYPLAZT12123
420 2 NSYPLAT12124 NSYPLAZT12124
1500 500 320 1 NSYPLAT1553 NSYPLAZT1553
420 1 NSYPLAT1554 NSYPLAZT1554
750 320 1 NSYPLAT1573 NSYPLAZT1573
420 1 NSYPLAT1574 NSYPLAZT1574
1000 320 2 NSYPLAT15103 NSYPLAZT15103
420 2 NSYPLAT15104 NSYPLAZT15104
1250 320 2 NSYPLAT15123 NSYPLAZT15123
420 2 NSYPLAT15124 NSYPLAZT15124
215
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories overview
Composition accessories
PB501394-SE-90
DB300633-52
PB500194-43
PB500183-34
Page 218 Page 219 Page 219
PB500175-19
DB300647-12
Page 220 Page 224 Page 225
PB501391-28
PB500184-28
Anti-burglary
accessory
PB502694-20
New
Page 227
216
Thalassa PLA Polyester floor-standing
enclosures
Common accessories overview
Cable management
Cable management Cable holding Cable ducting
PB502492-29
PB500966-40
PB500958-22
Page 270 Page 270 Page 289
Thermal management
Heaters Ventilation Cooling units
PB502503-29
PB501044-26
PB502614-15
Page 452 Page 406 Page 435
Thermal control
PB501162-19
Page 459
PB500189-17
PB502859-18
PB500190-29
217
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Coupling kits
DB300634-27
Trim frames Coupling frames
218
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
PB500194-49
PB500183-29
Characteristics Canopy Wall-mounting brackets Cable-entry plate
bb It can be installed in all enclosure models. Drilling positions and marks inside the bb Easy drilling in specific customised
bb High resistance to impacts, side panels. version.
temperature and bad weather. bb Incompatibility with: adapter plates,
bb Increases the height (A) of the step slides, internal door and chassis
enclosure by 38 mm, without modifying for modular distribution.
its width or depth.
Material Polyester reinforced with fibreglass Passivated zinc-coated Polyester reinforced with fibreglass
Colour RAL 7032 grey* - RAL 7032 grey*
Thickness - - 40/10e mm
Ingress protection rating - - IP00
Installation Essential for outdoor use - -
Mounting - bb Mounting on the sides by 4 or 6 lugs in -
horizontal position (6 lugs for enclosures
with height ≥ 1000 mm)
bb 10 mm mounting distance on the rear
of the enclosure plane
Maximum load - 180 kg -
Supply Delivered with the mountings required Set of 6 lugs and fixings Delivered with the mountings required
for installation for installation
Width (mm) Depth (mm) (C) References
500 320 NSYTJPLA53 NSYFMPLA NSYECPLAZ53
750 320 NSYTJPLA73 NSYECPLAZ73
1000 320 NSYTJPLA103 NSYECPLAZ103
1250 320 NSYTJPLA123 NSYECPLAZ123
500 420 NSYTJPLA54 NSYECPLAZ54
750 420 NSYTJPLA74 NSYECPLAZ74
1000 420 NSYTJPLA104 NSYECPLAZ104
1250 420 NSYTJPLA124 NSYECPLAZ124
Cable-entry plate
DB300641-25
DB300642EN-22
bb 1-door enclosure
187.5
DB300643-33
C–204
1111
C–78
A+38
C–204
10 25 C–78
10 B–40 25
B–40
bb 2-door enclosure
A-375 (1)
DB300643-33
C–78
C= 320/420 26
C–78
B+52
430 100
1010
3131
430 100
B–40
B–40
(1) For enclosures with height ≥ 1000 mm, 1 extra lug at the centre of the A-375 side.
* RAL 7035 from 2016.
PB500191-25
PLAT PLAZT
PB501055-25
Characteristics Grille for IP54 instead of IP44 Renovation and anti-graffiti paint
1 grille for 500 and 750 mm wide enclosures, 2 grilles 2-component paint system, specially formulated for Solvent bottles
for 1000 and 1250 mm wide enclosures. polyester enclosures. Renews enclosures and allows to be used as a
Prevents the entry of dust and provides the enclosure easy removal of graffiti. paint thinner or
with IP 5X protection at the top. Paint composed of: base (80 %) and hardener to clean brushes.
Maintains the possibility of ventilation. (20 %).
Colour RAL 7032 grey* RAL 7032 grey -
Installation It is installed from the inside in the upper ventilation - -
opening
Supply Delivered with G2 M1 standard synthetic filter, see 1 kg: 5 kg: 500 g
ClimaSys section vv 800 g tin of base paint vv 4 kg tin of base paint
vv 200 g tin of hardener vv 1 kg tin of hardener
(Coverage = 5 m2) (Coverage = 25 m2)
References
NSYCAG125LPF NSYAUPG1 NSYAUPG5 NSYAUPGS
* RAL 7035 from 2016.
219
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Base accessories
PLA PLAT
PB501739-15
PB501738-15
Characteristics ZA plinths
bb The frontal parts of the plinth (front and rear) have two stainless-steel screws protected by a
plastic cap; these screws, which can be accessed from the outside, make it possible (using an
Allen key) to open and remove the frontal parts for easier cable installation.
bb In stacked position, the bottom plinth can be partially buried.
bb It is provided with one or two reinforcement cross-rails, adjustable to adapt to the position of
the cables.
Material Polyester reinforced with fibreglass
Colour RAL 7032 grey*
Ingress protection rating IP44
Mechanical protection rating IK10
Standards IEC 61439-1
Mounting Four floor-attachment points; the symmetry of the parts prevents incorrect assembly
Supply The reference of the plinth contains all the accessories required for attaching the enclosure
to the plinth and for stacking two plinths
For floor-standing enclosure Plinth Height 200 mm Cable-gland area
Height Width Depth References Width (mm) Depth (mm) References Width Depth
(mm) (mm) (B) (mm) (C) (mm) (mm)
500 to 1500 500 320 NSYPLA(T)●53 494 250 NSYZA253 360 205
500 to 1500 750 320 NSYPLA(T)●73 744 250 NSYZA273 610 205
500 to 1500 1000 320 NSYPLA(T)●103 994 250 NSYZA2103 860 205
500 to 1500 1250 320 NSYPLA(T)●123 1244 250 NSYZA2123 1100 205
500 to 1500 500 420 NSYPLA(T)●54 494 350 NSYZA254 360 305
500 to 1500 750 420 NSYPLA(T)●74 744 350 NSYZA274 610 305
500 to 1500 1000 420 NSYPLA(T)●104 994 350 NSYZA2104 860 305
500 to 1500 1250 420 NSYPLA(T)●124 1244 350 NSYZA2124 1110 305
before completion of the floor. The plinths are attached by four feet
with a standard length of 750 mm. Possibility of horizontal
adjustment of the plinth.
bb Supply: the kit is made up of four feet and mountings.
Reference
NSYAEBFZ
220
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Base accessories
PB500180-33
N plinths
Designed to be installed under the closed-bottom enclosures (version PLA or PLAT).
Height 60 mm
References
NSYZNPLA53
NSYZNPLA73
NSYZNPLA103
NSYZNPLA123
NSYZNPLA54
NSYZNPLA74
NSYZNPLA104
NSYZNPLA124
DB300635-25
20
Depth (mm)
320 Linking parts for N plinth on 320-mm H plinth NSYAZ3PLA
20
B+ 420 Linking parts for N plinth on 420-mm H plinth NSYAZ4PLA
DB300637-19
DB300638-60
B D12
NSYPLA or
NSYPLAT C
50
0/4
20
20 D14
B+
30
65
NSYZNPLA…
16
0/2
27 60
0/3
70
NSYAZ… 30
62
200
700
NSYZHPLA…
35
C- B+
10
221
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Base accessories
PLAZ PLAZT
PB501743-15
PB501742-14
completion of the floor. The plinths are attached by four feet with
a standard length of 750 mm. Possibility of horizontal adjustment
of the plinth.
bb Supply: the reference includes a kit made up of four feet and
mountings.
Reference
NSYAEBFZ
(1) The coupling kit NSYMUPLA••• is not valid for enclosures using ZZ or ZH type plinths.
(2) RAL 7035 from 2016.
222
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Base accessories
PB500181-16
DB300639-56
PB501368-52
C-
16
0
60
B-
Height 900 mm
References References
NSYZHPLA53 NSYMFPLAZ53
NSYZHPLA73 NSYMFPLAZ73
NSYZHPLA103 NSYMFPLAZ103
NSYZHPLA123 NSYMFPLAZ123
NSYZHPLA54 NSYMFPLAZ54
NSYZHPLA74 NSYMFPLAZ74
NSYZHPLA104 NSYMFPLAZ104
NSYZHPLA124 NSYMFPLAZ124
DB300636-25
C Floor-mounting studs
bb Description: set of four threaded parts and mountings, for mounting the
enclosures on concrete plinths.
Reference
NSYFSPLAZ
200
DB300640-25
305
395
B+35
C-
10
223
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Door
PB500175-22
PB501750-25
DB300645-19
DB300644-24
25 (1)
30 (2)
D
C–40
C E
Door accessories
PB500178-29
PB500179-28
PB500186-36
224
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Locking system
DB300649-23
1
2
1 Block with form insert.
2 Block with cylindrical barrel.
3 3 Block with semi-cylindrical barrel.
** New
to the lock-control insert.
Opening diameter: 14 mm.
Options for changing the blocks with References
semi-cylindrical barrels
1242 E key NSYIN1242E2
DIN adapter NSYINDIN2 Reference
JIS key NSYINKJIS2 NSYBCPLA
Reinforced key NSYINKR2
FAC key NSYINKFAC2
225
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
PB500151-22
PB500103-15
PB500102-21
Characteristics Metallic mounting plate Insulating mounting plate
Plain mounting plate Telequick mounting plate
bb Direct installation on M8 inserts at the bb Grille with 11 x 26 mm drill holes, with a step of 1 bb Direct installation on M8 inserts at
rear of the enclosure or on step slides for 5 x 30 mm, for direct installation, with clip nuts, the rear of the enclosure or on step
depth adjustment (see page 230). The of all the devices with mounting at 2, 3 or 4 points, slides for depth adjustment (see page
enclosures with height of ≥ 1000 mm have by screws with diameters of 3, 4, 5 or 6 mm. 230). The enclosures with height of
intermediate impressions for installing bb Direct installation on M8 inserts at the rear of the ≥ 1000 mm have intermediate
mounting plates of a lesser height (M8 enclosure or on step slides for depth adjustment impressions for installing mounting
inserts, ref. NSYTEX8, to be ordered (see page 230). The enclosures with height of plates of a lesser height
separately). ≥ 1000 mm have intermediate impressions for (M8 inserts, ref. NSYTEX8, to be
bb In the 2-door enclosures, it is possible to installing mounting plates of a lesser height (M8 ordered separately).
install 1 complete mounting plate or 2 inserts, ref. NSYTEX8, to be ordered separately). bb In the 2-door enclosures, it is
individual mounting plates. possible to install 1 complete
mounting plate or 2 individual
mounting plates.
Material Galvanised sheet-steel Galvanised sheet-steel Bakelite Polyester
Finish - - - -
Colour - - - -
Thickness 25/10e mm - 40/10e mm bb 40/10e mm up
to 700 mm height
bb 50/10e mm from
800 mm height
Maximum load 150 kg/m2 150 kg/m2 100 kg/m2
Supply - - 1 mounting plate
For enclosure (mm) Dimensions References Dimensions References References
Height (A) Width (B) H Surface E D Surface
(mm) (dm2) (mm) (mm) (dm2)
500 500 - 14 NSYPMM55 350 350 13 NSYPMR55 NSYPMB55 NSYPMA55
750 - 24 NSYPMM75 350 600 23 NSYPMR57 NSYPMB75 NSYPMA75
1000 437.5 32 NSYPMM510 350 2 x 350 26 2 x NSYPMR55 NSYPMB510 NSYPMA510
1250 - 38 NSYPMM55 + 350 350 + 36 NSYPMR55 + NSYPMB55 + NSYPMA55 +
NSYPMM75 600 NSYPMR57 NSYPMB75 NSYPMA75
750 500 - 24 NSYPMM75 600 350 23 NSYPMR75 NSYPMB75 NSYPMA75
750 - 40 NSYPMM77 600 600 38 NSYPMR77 NSYPMB77 NSYPMA77
1000 437.5 54 NSYPMM710 600 2 x 350 46 2 x NSYPMR75 NSYPMB710 NSYPMA710
1250 687.5 70 NSYPMM712 600 350 + 61 NSYPMR75 + NSYPMB712 NSYPMA712
600 NSYPMR77
1000 500 - 33 NSYPMM105 850 350 32 NSYPMR105 NSYPMB105 NSYPMA105
750 - 55 NSYPMM107 850 600 54 NSYPMR107 NSYPMB107 NSYPMA107
1000 437.5 74 NSYPMM1010 850 2 x 350 64 2 x NSYPMR105 NSYPMB1010 NSYPMA1010
1250 687.5 96 NSYPMM1012 850 350 + 86 NSYPMR105 + NSYPMB1012 NSYPMA1012
600 NSYPMR107
1250 500 - 42 NSYPMM125 1100 350 42 NSYPMR125 NSYPMB125 NSYPMA125
750 - 70 NSYPMM127 1100 600 70 NSYPMR127 NSYPMB127 NSYPMA127
1000 437.5 96 NSYPMM1210 1100 2 x 350 84 2 x NSYPMR125 NSYPMB1210 NSYPMA1210
1250 687.5 124 NSYPMM1212 1100 350 + 112 NSYPMR125 + NSYPMB1212 NSYPMA1212
600 NSYPMR127
1500 500 - 51 NSYPMM155 1350 350 51 NSYPMR155 NSYPMB155 -
750 - 85 NSYPMM157 1350 600 85 NSYPMR157 NSYPMB157 -
1000 437.5 118 NSYPMM1510 1350 2 x 350 102 2 x NSYPMR155 NSYPMB1510 -
1250 687.5 152 NSYPMM1512 1350 350 + 136 NSYPMR155 + NSYPMB1512 -
600 NSYPMR157
10.5 25 25 10.5 25 25 e E+20 10.5 25 25 10.5 25 25 e
DB300651EN-46
DB300652-25
DB300651EN-46
E
25
25
25
25
A-110 (2)
25
25
25
25
A-150
A-150
D+26
100 100
75
75
226
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Installation accessories
PB502664-20
PB502916-12
PB501384-14
New
PB501382-26
H
B-95
Side mounting plates Partial plain mounting plate Technical uprights Anti-burglary accessory
Polyester mounting plates fixed to the sides of the Direct mounting on the uprights, with bb Supports for mounting rails, Anti-burglary accessory for polyester
enclosure for additional installations. Installation the notched sliding nuts or pivoting perforated grilles and plain outdoor Heavy Duty in accordance
on the M8 bosses by adding inserts, ref. nuts, see common accessories partial mounting plates. with
NSYTEX8. section. bb Details in the common ENV 1627-1630:2011 class 2. It
accessory section. keeps the Insulation
bb Mounting at the rear on the Class II according to
M8 inserts or on the step slides. IEC 61439-1:2011.
Note: the diagrams above relate to the metal mounting plates. The mounting plates made from insulating material only have 4 or 8 main mounting points
and the external dimensions of the diagrams.
227
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Installation accessories
PB500174-22
Characteristics Modular distribution chassis*
bb Chassis for modular switchgear, installed directly in the sealed enclosures (PLA version).
For installation in enclosures with open bottom part (PLAZ version) it is necessary to use
a set of adapter plates (ref. NSYPTZ●●●).
bb Chassis made up of cover plates on a rigid structure.
bb Quick installation without mountings.
bb Distance between rail and front panel with adjustable depth from 40 to 85 mm.
bb System for identifying electrical circuits supplied.
bb Neutral/earth strip: 2 x 16 mm2 + 5 x 6 mm2 included in the standard offer.
bb Incompatibility with: cable-entry plate, internal door, door switch and door retainer
(ref. NSYRETPLAU).
Material bb Rigid structure: galvanised-steel
bb Cover plates: self-extinguishing insulating
Colour Cover plates: RAL 7032 grey**
Thickness -
Installation -
Maximum load -
For enclosure (mm) No. of No. of Rows for module No. of References
doors rows plates
Height (A) Width (B) No. No. of
18-mm
modules
750 500 1 4 4 76 - NSYDLP76
1 4 3 57 1 NSYDLP57
750 1 4 4 132 - NSYDLP132
1 4 3 99 1 NSYDLP99
1000 2 4+4 4+4 152 - 2 x NSYDLP76
2 4+4 3+3 114 1+1 2 x NSYDLP57
1250 2 4+4 4+4 208 - NSYDLP76 + NSYDLP132
2 4+4 3+3 156 1+1 NSYDLP57 + NSYDLP99
1000 500 1 6 6 114 - NSYDLP114
1 6 5 95 1 NSYDLP95
750 1 6 6 198 - NSYDLP198
1 6 5 165 1 NSYDLP165
1000 2 6+6 6+6 228 - 2 x NSYDLP114
2 6+6 5+5 190 1+1 2 x NSYDLP95
1250 2 6+6 6+6 312 - NSYDLP114 + NSYDLP198
2 6+6 5+5 260 1+1 NSYDLP95 + NSYDLP165
1250 500 1 7 7 133 - NSYDLP133
1 7 6 114 1 NSYDLP114P
750 1 7 7 231 - NSYDLP231
1 7 6 198 1 NSYDLP198P
1000 2 7+7 7+7 266 - 2 x NSYDLP133
2 7+7 6+6 228 1+1 2 x NSYDLP114P
1250 2 7+7 7+7 364 - NSYDLP133 + NSYDLP231
2 7+7 6+6 312 1+1 NSYDLP114P + NSYDLP198P
1500 500 1 9 9 171 - NSYDLP171
1 9 8 152 1 NSYDLP152
750 1 9 9 297 - NSYDLP297
1 9 8 264 1 NSYDLP264
1000 2 9+9 9+9 342 - 2 x NSYDLP171
2 9+9 8+8 304 - 2 x NSYDLP152
1250 2 9+9 9+9 468 1+1 NSYDLP171 + NSYDLP297
2 9+9 8+8 416 1+1 NSYDLP152 + NSYDLP264
* Other modular distribution accessories on page 232.
** RAL 7035 from 2016.
228
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Installation accessories
PB501387-55
Dimensions
Modular distribution chassis
(500)
DB300660-71
(1500)
(500)
(1250)
(500)
(1000)
(500)
(750)
(500)
(1500)
(500)
(1250)
(500)
(1000)
(500)
(750)
PB501388-41
(750)
(1500)
(750)
(1250)
(750)
Details of the depth (1000)
adjustment. (750)
(750)
PB501389-37
(750)
(1500)
(750)
(1250)
(750)
(1000)
(750)
(750)
Detail from front-panel
mounting.
DB300661-90
85
Min : C–178
40
45
Detail from the circuit-
46
42/67(1)
marking system.
85
40
16
85
40
150
85
40
85 25
85
40
40
85
40
(2)
(1) Dimensions of 42 or 67 mm or a pitch of 25 mm, according to the M8 boss chosen for the
installation. See details in the enlarged image on the right. In the enclosures with glazed doors,
the 2 dimensions are reduced by 5 mm.
(2) C = Depth of the enclosure.
229
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Installation accessories
PB500176-44
PB501379-26
PB501380-28
NSYPTZ●●● NSYPTZ●●●2P
ref. NSYPTZ●●●
PB501378-50
35 62 (1)
Set of 4 additional brackets, to be slid into the step slides,
250/350
DB300654-29
230
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
Installation accessories
DB300659-36
PB501386-10
PB501385-29
PB500187-26
Characteristics Support plate M8 inserts Intermediate support in the
2-door enclosures
bb Designed to support assorted To be placed in the bosses moulded on the Required accessory for installing support
equipment or simply to install a doors, uprights, rear panels and bottom plates, ref. NSYBANPLA●●● or uprights,
separation. and top parts, for mounting accessories ref. NSYSPLA●●● in the 2-door
bb In the 2-door enclosures, and assorted devices. enclosures.
the installation of the plate or the
uprights requires the prior installation
of an intermediate support,
ref. NSYSBPLA, presented beside.
Material Galvanised steel - -
Installation bb It is installed directly on the bottom - -
part of the enclosure
bb For the installation of one or several
support plates, use 2 sets of 2 uprights
suitable for the height (to be ordered
separately). These uprights offer the
option of adjusting the height with
a step of 50 mm
Supply Delivered with the mountings required References by unit. Order by multiples -
for installation of 8 units (8, 16, 24, etc.)
For enclosure (mm) Upright
Height Depth No. of References Reference Reference
adjustments
750 320 2 2 x NSYSPLA75 NSYTEX8 NSYSBPLA
420
1000 320 3 2 x NSYSPLA100
420
1250 320 4 2 x NSYSPLA125
420
1500 - 5 2 x NSYSPLA150
For enclosure (mm) Plate
Depth (C) Width (B) Max. load References
320 500 60 kg NSYBANPLA53
750 60 kg NSYBANPLA73
420 500 50 kg NSYBANPLA54
750 50 kg NSYBANPLA74
620 500 50 kg NSYBANPLA56
750 50 kg NSYBANPLA76
Upright
PB501288-30
DB300658-23
12
300
11 x 13
200
200
(1)
200
(2)
200
(3)
(4)
Plate
12
DB300657-27
25
C–80
27 18
B–42
231
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
PB501391-46
PB501392-46
Characteristics Plain cover plate Plain mounting plate
Plain cover plate for non-modular switchgear bb Plate for mounting non-modular devices.
protection. bb Depth-adjustable mounting on the supports
from 40 to 85 mm.
bb Nominal height: 150 mm or 300 mm.
Material Self-extinguishing insulating Galvanised steel
Colour RAL 7032 grey* -
Thickness - 20/10e mm
Supply Order by multiples of 2 (2, 4, 6...) Order by multiples of 2 (2, 4, 6...)
For enclosure (mm) Dimensions (mm) References
Width Height Width
500 146 402 NSYCTL500DLP -
149 361 - NSYPMP500DLP
298 361 - NSYPMP5002DLP
750 146 652 NSYCTL750DLP -
149 611 - NSYPMP750DLP
298 611 - NSYPMP7502DLP
DB300662-42
DB300663-43
149/298
21 13
146
361/611 10 x 45º
25 25
402/652
232
Thalassa PLA Polyester floor-standing
enclosures
Specific accessories
19” chassis
PB500184-40
PB500185-40
Enclosure with 19” fixed chassis. Enclosure with 19” swing chassis.
44.45
31.75
31.75
44.45
44.45
12.7
44.45
12.7
465 465
485 55
750 750
300
325
420
420
77
44
Recommendation
Intermediate support
DB300659-33
Reference
NSYSBPLA
233
Accessories
234
Universal Enclosures Accessories
Contents
PB500222-18
Mounting 236
PB500072-12
PB500023-24
PB500218-32
PB500223-27
PB500217-21
235
Accessories Mounting
Mounting plates for wall-mounting
enclosures
PB500101-18
PB500072-13
PB500100-13
PB500102-18
Telequick
236
Accessories Mounting
Mounting plates for wall-mounting
enclosures
DB300754-7
PB500104-18
PB500103-11
PB500151-15
Telequick
AM1-PA
Bakelite mounting plate Polyester mounting plate DIN-rail chassis Joinable Telequick
mounting plate
bb They are coupled directly to the rear of the actual enclosure or to the sliding Components supplied with a DIN-rail chassis: 20/10e mm Telequick
plate supports. bb Aluminium uprights. mounting plates. These
bb Double-door enclosures offer the option of installing one full plate or bb DIN rails (symmetric section A or B, mounting plates are suitable
two individual plates. See guide below. according to the reference). for mounting vertically
bb Screws, washers and nuts need to mount multiple plates.
the DIN rails to the uprights. 11 x 26 mm slots.
bb Batch of 4 adapters, ref. NSYAMCSF, Switchgear mounting by
needed to fix the uprights to the enclosure. clip-on nuts.
Bakelite Polyester reinforced with fibreglass Aluminum and zinc-coated steel Zinc-coated steel
RAL 9005 black RAL 7035 grey - -
1 mounting plate without mounting 1 mounting plate and mounting 1 DIN-rail chassis 1 mounting plate and
elements elements mounting elements
Dimensions Thick. References Dimensions Thick. References Type of rails No. of rails References Dimensions References
(mm) (mm) (mm) (mm) (mm)
H (P) W (S) H (P) W (S) H W
- - - - - - - - - - - 120 734 AM1PA0670
- - - - - - - - - - - 180 734 AM1PA1270
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - 349 228 AM1PA3015
- - - - - - - - - - - 349 258 AM1PA3020
265 150 4 NSYMB32 265 150 4 NSYMPP32 - - - - - -
265 200 4 NSYMB3025 265 200 4 NSYMPP3025 - - - - - -
265 250 4 NSYMB33 - - - - B 4 NSYMD33 - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - 360 534 AM1PA3050
- - - - - - - - - - - - - -
- - - - - - - - - - - 360 734 AM1PA3070
325 250 4 NSYMB43 325 250 4 NSYMPP43 B 4 NSYMD43 - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - 465 334 AM1PA4030
- - - - - - - - - - - - - -
465 350 4 NSYMB54 465 350 4 NSYMPP54 B 4 NSYMD54 - - -
- - - - - - - - - - - - - -
565 350 4 NSYMB64 565 350 4 NSYMPP64 B 6 NSYMD64 660 434 AM1PA6040
565 450 4 NSYMB65 - - - - - - - 660 534 AM1PA6050
- - - - - - - - A 6 NSYMD66 660 634 AM1PA6060
- - - - - - - - - - - 660 734 AM1PA6070
- - - - - - - - - - - - - -
665 450 4 NSYMB75 665 450 4 NSYMPP75 B 6 NSYMD75 - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - 765 534 AM1PA7050
- - - - - - - - - - - 855 634 AM1PA8060
765 550 4 NSYMB86 765 550 5 NSYMPP86 A 6 NSYMD86 - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - 960 534 AM1PA9050
- - - - - - - - - - - 960 634 AM1PA9060
- - - - - - - - - - - 960 734 AM1PA9070
965 550 4 NSYMB106 - - - - - - - - - -
965 750 4 NSYMB108 965 750 5 NSYMPP108 A 6 NSYMD108 - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - A 7 NSYMD128 - - -
1150 950 4 NSYMB1210 - - - - - - - - - -
- - - - - - - - - - - - - -
- - - - - - - - - - - - - -
** To install two mounting plates in a single enclosure, also order reference NSYCRNGSDR.
See details on page 240.
To install the plate in an enclosure with 6 studs, also order reference NSYEMR.
237
Accessories Mounting
Mounting plates for wall-mounting
enclosures
DB300310EN-61
10.5
A
A
H - 25
H
18.5
W - 25
W
Only for 1000 x 800
25 25 25 12.5 12.5
DB300311EN-40
12.5
DB300388EN-20
25 25 20
25 12.5
Ø8 Ø 8.5
Ø 6.5
18.5
W ±0.5
Detail B
Ø 3.6 25
12.5 Ø8
H ±0.5
See
12.5
detail B
12.5
25
12.5 2.5
15
25
See
detail A 7 4
Detail A 8.5
4 26 R=15
X
2
15 15 7.5
11
4
C
A
R=5
7.5
D 15
X
238
Accessories Mounting
Mounting plates for wall-mounting
enclosures
DB300756-44
DB300757-50
30
=
(1) (1)
H+60
(1)
349
H
300
349
30 30 15
11 228
=
11 = 195 = Ø 15 (2)
258 13 17 G 17 (2)
G+34
Ø 6.5
A-75
Ø 8.5
20 25 25
B-10
1
10
5.5
P
12.5 25 25
1.5
7
35
B-75
P = Height
15
S = Width B
15 7.2
DB300317EN-161
5.5
B
7.2
DB300318EN-131
10
1.5
35
1
35
1
35
Type A Type B
2000
239
Accessories Mounting
Step slides for wall-mounting enclosures
S3D S3X
PB502726-41
PB502721-32
PB502725-42
Characteristics Step slides for mounting plate Step slides for 2 mounting Slide bracket for 2 mounting
plates in one enclosure plates at different depths
Set of 4 supports intended for installation In 1000 and 1200 mm wall-mounting Additional slide bracket to be installed on
in enclosures with depths of 200, 250, enclosures, it is possible to install the central step slides in order to mount
300 and 400 mm. The rail allows the 2 mounting plates side by side, using 2 mounting plates, side by side,
depth of the plate and other accessories the additional central step slides. in different depths.
to be adjusted in steps of 12.5 mm.
Supply 4 step slides 2 step slides 2 slide brackets
For enclosure References
Depth (mm)
200 NSYSDCR200 - NSYCRNGSDR
250 NSYSDCR250 -
300 NSYSDCR300 NSYSDRSDCR300*
400 NSYSDCR400 NSYSDRSDCR400*
(3)
DB300319EN-40
DB300321-37
DB300320-41
12.5
(1)
(6)
30 44 (4)
(6)
(5) (2)
PB500782-44
See detail A
(4)
(4)
DB300320-41
Detail A
* Not applicable for stainless steel enclosures.
240
Accessories Mounting
Vertical rails for wall-mounting enclosures
PB500105-39
DB300758-20
Telequick Telequick
Sliding Nuts
Sliding nuts to be used on aluminium
10
PB501766-24
58
vertical rails.
Type Supply References
(units)
M4 100 NSYNM4
M5 100 NSYNM5
a
M6 100 NSYNM6
10
Reference
NSYAMCSF
15 29 14
to be adjusted.
Supply: 10 units. References per unit.
To be ordered in multiples of 10
(10, 20, 30, etc.).
Type References
Notched clamp nuts
DZ5-MFp
Specially designed for pre-drilled
DB300760-23
uprights.
enclosures with depths of
Supply: 100 units. Reference by
150 and 200 mm
unit. Order by multiples of 100
130-mm slide with bracket NSYSB130 (100, 200, 300...).
for enclosures with depths of
250 and 300 mm Type Weight (g) References
Bracket for slides NSYFB M6 7.0 DZ5MF6
(customised mounting plate) AF1-VAppp
M8 8.0 DZ5MF8
25
PB500781
DB300322EN-130
DB300316-22
24
9 15 7.5
5.5
15
33
33. 1.5
16
33 1.5 1
32
33.
27
35
27
2.5
1.5
10 15
.5
10.5
1
Ref. NSYAMCSF
241
Accessories Mounting
Mounting plates for floor-standing
enclosures
PB500477-12
PB500824-24
PB500807-24
Telequick Telequick
SM SF SM SF SD SM SF
SMX SFX SMX SFX SDX SFX
Characteristics Plain mounting plate Perforated mounting plate "Telequick" Partial mounting plate
bb Depth adjustable with a pitch of bb Allows the installation of switchgear without drilling Partial mounting plate, provided
25 mm, provided with plastic shoe for or screwing. with reinforcement flange on its
easier sliding. bb Plate designed for quick mounting of switchgear by four sides.
bb Once the plate is fixed, in advanced means of clip-on nuts ref. NSYKNM3 to NSYKNM6.
position, the sliding shoe can be easily bb Vertical continuity is guaranteed by the vertical
removed, to increase the available installation of plates.
plate surface. bb The top plate must be fixed in the third hole, 80 mm
bb In sets made up of two or more from the top frame.
enclosures with mounting plates, it is
possible to obtain a continuous plate
surface using intermediate mounting
plates (see page 243).
Material Galvanised steel Zinc-coated steel Galvanised steel
Mounting Mounting options: Mounting options: Mounting options:
bb At the sides of the enclosure with the bb Directly to the vertical uprights of the structure, bb Spacial SF, SFX:
orthogonal brackets (see page 246) by means of self-tapping screws (only Spacial SF) vv Mounting to the vertical uprights
bb Back-to-back, with the brackets for bb To the technical vertical uprights, by means of sliding of the structure
mounting the mounting plates in nuts, page 250; to standard uprights by means of flat vv Mounting to technical or standard
back-to-back position (see page 247) nuts, page 250 or self-tapping screws, and to cross rails vertical uprights, page 250
vv For installations in advanced
position, mounting to cross-rails,
see page 254
bb Spacial SM:
vv Mounting by means of adaptation
profiles and 40-mm universal
cross-rails (1 row) in vertical
position, or also on horizontal
universal cross-rails
vv It can be mounted horizontally,
as a tray, by means of depthwise
cross rails, see page 254
Maximum load 600 kg in the back of the enclosure and - -
500 kg in the intermediate position
Supply One mounting plate and sliding shoes One perforated mounting plate and mounting elements Partial mounting plate and mounting
for technical uprights and screws for mounting to the elements
structure or cross rails
Dimensions (mm) Dimensions (mm) References Plate height (mm) Useful References Plate Plate References
surface height length
(dm2) (mm) (mm)
Width (B) Height (A) D E F G H B-100
600 1200 NSYMP126 450 200 - 100 11.4 NSYSTMP2260 247 500 NSYSPMP2560
1400 NSYMP146 450 425 - 325 22.8 NSYSTMP4560 247 750 NSYSPMP2575
1600 NSYMP166 450 575 125 475 30.4 NSYSTMP6060 397 500 NSYSPMP4060
1800 NSYMP186 450 800 250 700 11.9 NSYSTMP8260 597 500 NSYSPMP6060
2000 NSYMP206
2200 NSYMP226
800 1200 NSYMP128 650 200 - 100 15.9 NSYSTMP2280 247 700 NSYSPMP2580
1400 NSYMP148 650 425 - 325 31.8 NSYSTMP4580 397 700 NSYSPMP4080
1600 NSYMP168 650 575 125 475 42.4 NSYSTMP6080 597 700 NSYSPMP6080
1800 NSYMP188 650 800 250 700 58.4 NSYSTMP8280
2000 NSYMP208
2200 NSYMP228
1000 1200 NSYMP1210 850 200 - 100 20.4 NSYSTMP22100 247 900 NSYSPMP25100
1400 NSYMP1410 850 425 - 325 40.8 NSYSTMP45100 397 900 NSYSPMP40100
1600 NSYMP1610 850 575 125 475 54.4 NSYSTMP60100 597 900 NSYSPMP60100
1800 NSYMP1810 850 800 250 700 74.9 NSYSTMP82100
2000 NSYMP2010
2200 NSYMP2210
1200 1200 NSYMP1212 1050 200 - 100 24.9 NSYSTMP22120 247 1100 NSYSPMP25120
1400 NSYMP1412 1050 425 - 325 49.9 NSYSTMP45120 397 1100 NSYSPMP40120
1600 NSYMP1612 1050 575 125 475 66.5 NSYSTMP60120 597 1100 NSYSPMP60120
1800 NSYMP1812 1050 800 250 700 91.5 NSYSTMP82120
2000 NSYMP2012
2200 NSYMP2212
1600 1800 NSYMP1816 Order two 800-mm plates 397 1100 NSYSPMP40160
2000 NSYMP2016
242
Accessories Mounting
Mounting plates for floor-standing
enclosures
SF SFX
PB500788-29
PB500793-31
PB500784-24
PB500786-22
Characteristics Intermediate Intermediate Intermediate Reinforcement for
mounting plate mounting of mounting mounting of the mounting plate
plate, located in the mounting plate,
back of the enclosure in advanced position
bb Obtains a continuous bb Support for additional bb Support for additional bb Reinforcement kit for
surface of the mounting plate mounting of the mounting mounting of the mounting transversal mounting plate.
at enclosure suites. plate, at any height of the plate, at any height of the bb Provides extra rigidity to the
bb Adjustable depth with a plate, when the plate is plate, when the plate is mounting plates and absorbs
pitch of 25 mm. When the mounted in the back mounted in advanced position. vibrations.
mounting plates are located of the enclosure. bb The supports minimise the bb Can be used as a support
in the back of the enclosure, bb The supports minimise the vibration of the plate during for mounting very heavy
the vertical profiles of the vibration of the plate during the transport and operation elements.
structure are flush with the transport and operation of the panel.
the plates, acting as an of the panel.
intermediate mounting plate.
In this case the intermediate
plate cannot be installed.
Material Galvanised steel Zinc-coated steel Zinc-coated steel Zinc-coated steel
Thickness - - - 15/10e mm
Mounting - bb The supports are fixed to The supports are mounted -
the structure when the plate on light cross rails or on
is already located in the back 40-mm (1 row) universal
of the enclosure or quick-mounting cross rails
bb Spacial SM: mounting to (not supplied), see page 254
40-mm universal cross rails
(1 row), installed vertically
in the back of the enclosure,
see page 254
Supply One intermediate plate and Ten units and mounting Ten units and mounting Two profiles, four supports for
mounting elements elements. Reference by unit. elements. mounting to the mounting plate
Order by multiples of 10 (10, Reference by unit. Order by and mounting elements
20, 30…) multiples of 10 (10, 20, 30…)
Dimensions (mm) References
Height (A) Width (B)
1200 - NSYSIMP12 NSYSMPFB NSYSMPFA -
1400 - NSYSIMP14 -
1600 - NSYSIMP16 -
1800 - NSYSIMP18 -
2000 - NSYSIMP20 -
2200 - NSYSIMP22 -
- 800 - NSYMPRK8
- 1000 - NSYMPRK10
- 1200 - NSYMPRK12
- 1600 - NSYMPRK16
PB500794-33
PB500785-26
PB500787-34
243
Accessories Mounting
Mounting plates for floor-standing
enclosures
Dimensions
Plain mounting plate
DB300565-48
Ø 22
Ø9
Advantages
bb The Spacial.pro tool helps determine the
optimum dimensions of the mounting plate.
A-103
A-150
DB300568-202
F F
E+25
E
G
Ø 8.5
30 D
D+58 (1) Cut-outs 11 x 26 with
4 x Ø 12.5 x 8.5 a pitch of 15 x 30.
PB500826-23
PB500827-23
PB500828-22
H
2.5
244
Accessories Mounting
Mounting plates for floor-standing
enclosures
DB300570EN-63
min. = 50 mm
Reinforcement for mounting plate
DB300569-30
20
40
Reference
NSYS16M5HS
245
Accessories Mounting
Mounting plate brackets for floor-standing
enclosures
PB500790-30
Characteristics Mounting plate mounting brackets Orthogonal brackets
bb For direct mounting on the structure of the enclosure. bb Designed for the installation of mounting plates on the sides
bb Adjustable depth with a pitch of 25 mm. of the enclosure.
bb In the event of installing one plate in the back of the
enclosure and one plate at the side, they must both be installed
using orthogonal brackets.
bb Spacial SFX: to mount the lateral mounting plate, remove
the one on the back and its mounting brackets.
Material Zinc-coated steel Zinc-coated steel
Maximum load 4 brackets: 600 kg 4 brackets: 600 kg
Supply Four brackets and mounting elements Four brackets and mounting elements
References
Spacial SF Spacial SM, Spacial SFX,
Spacial SMX
NSYSFPB NSYSMPB NSYSMPSB
PB500791-35
246
Accessories Mounting
Mounting plate brackets for floor-standing
enclosures
SF SF SF SFX
PB500797-30
PB500795-34
PB502604-48
Mounting plate sliding rails Brackets for mounting mounting Brackets for mounting intermediate
plates mounting plates in back-to-back
in back-to-back position position
bb Rails which the mounting plate slides along when bb Doubling the mounting surface. bb Doubling the mounting surface.
inserted in the enclosure. bb Adjustable with a pitch of 25 mm. bb Adjustable with a pitch of 25 mm.
bb Once the mounting plate is installed and fixed
to the brackets, the sliding rails can be removed
to maximise the cable passage surface, and can
be installed depthwise in other positions.
Depth (mm)
DB300572EN-53
28.25
28.25
28.25
C-90
C
C-90
C
28.25
C: Enclosure depth.
30 2525
C: Enclosure depth.
PB502603-32
PB500796-37
PB500798-30
247
Accessories Mounting
Mounting rails for floor-standing
enclosures
SF SFX
PB500799-45
Characteristics Side entry rails for the mounting plate
bb Side entry device for the mounting plates when coupling Spacial SF enclosures
or Spacial SFX.
bb The mounting plates can be coupled with one another, and are fixed to the side
entry guide by pressure.
Examples of combination
Length of joined Example of Spacial SF Example of combining Useful length
Spacial SF enclosure combination mounting plates by (mm)
enclosures (mm) width (mm) (B) width (mm)
1200 1200 600 + 800 1192
1400 600 + 800 600 + 1000 1392
1600 2 x 800 800 + 1000 1592
1800 3 x 600 800 + 1200 1792
2000 2 x 1000 1000 + 1200 1992
2200 600 + 2 x 800 1200 + 1200 2192
2400 3 x 800 1600 + 1000 2392
3 x 600 + 1000 2384
2600 2 x 1000 + 600 1600 + 1200 2592
3 x 600 + 1200 2584
2800 2 x 1000 + 800 4 x 800 2784
3000 3 x 1000 3 x 800 + 1000 2984
3200 2 x 1000 + 1200 3 x 800 + 1200 3184
3400 3 x 800 + 1000 800 + 3 x 1000 3384
3600 3 x 1200 4 x 1000 3584
3800 800 + 3 x 1000 600 + 3 x 1200 3784
4000 4 x 1000 800 + 3 x 1200 3984
248
Accessories Mounting
Mounting rails for floor-standing
enclosures
SM SF
PB500804-45
PB500801-45
Top/bottom adjustment rails Kit for adapting two-door enclosures
bb Allows the installation of two mounting plates or vertical uprights in bb Allows the installation of two mounting plates as if in two independent
enclosures with a width of 1200 mm, as if in two independent enclosures. enclosures.
bb A set of mounting plate mounting brackets ref. NSYSMPB is required for this. bb A set of brackets for fixing mounting plates ref. NSYSMPB is required for this.
bb Optional installation of an intermediate mounting plate. bb Option of installing an intermediate mounting plate.
bb Valid for enclosures with widths of 1200 and 1600 mm.
bb In the event of installing a cable-gland plate for a width of 1200 mm, it is
necessary to install two with a width of 600 mm, and for widths of 1600 mm,
two with a width of 800 mm.
- -
2 rails, top and bottom, and fixing elements Two 90 mm cross rails, cable-gland plate support, 2 brackets for central fixing
of the roof and fixing elements
References References
- -
- -
- -
- -
NSYSTBR3 -
NSYSTBR4 NSYSMP2D4
NSYSTBR5 NSYSMP2D5
NSYSTBR6 NSYSMP2D6
- NSYSMP2D8
PB500805-75
PB500806-75
PB500802-36
PB500803-34
249
Accessories Mounting
Uprights for floor-standing enclosures
PB500483-22
PB500482-16
Telequick Telequick
SM SF SD SM SF SMX SFX
SMX SFX SDX PLA
DB300574EN-28
50 23
25
25 48
25
Ø 3.6
A–25
A
A
0
Ø1
48 25
50
25
23
45 Ø 9 x 14 13 x 11 10 50
20
30
34
Nuts and screws for technical uprights Nuts and screws for standard uprights
PB500783-7
PB500817-14
PB500783-7
PB500819-7
PB500818-15
(3)
(1)
(2)
* Control desk.
(1) M6 quarter-turn sliding nut
(2) M6 quarter-turn serrated sliding nut
(3) M6 renovable nut
Reference
NSYMFB
250
Accessories Mounting
Other support brackets
SM SF SD
Telequick Telequick Telequick
SMX SFX SDX
PB502722-14
PB501769-16
PB502724-17
PB502723-20
PB501770-27
Characteristics Rail support bracket Combined support Terminal-block Mounting Combined
bracket support bracket brackets for the support bracket
earthing strip (vertical)
Bracket for mounting rails at Allow the installation of a DIN bb They allow the bb They allow the Allow the installation
an angle of 45°. rail and an earthing strip on mounting of a DIN rail. mounting of an of a DIN rail and an
different planes, to minimise bb Tilted to 45°. earth-collector rail earthing strip on
the cable radiuses. and a DIN rail. different planes, to
bb Tilted to 30°. minimise the cable
bb Earthing strip, radiuses.
ref. NSYECB1M153.
See page 302.
Material Zinc-coated steel Zinc-coated steel Treated steel - Zinc-coated steel
Installation bb Spacial SF: mounted on bb Spacial SF: directly on - To be fixed on mounting Spacial SF/SM: directly
the structure and/or the structure and/or using plate. on the vertical structure
mounting plates mounting plates and/or using mounting
bb Spacial SM: mounted on bb Spacial SM: on the plates
the bottom mounting rail and/ bottom adjustment rails and/
or mounting plates or on mounting plates
Supply Ten units and mounting Ten combined support 2 lugs and mountings 2 mounting brackets and 10 brackets
elements. Reference by unit. brackets & mount elements. mounting elements
Order by multiples of 10 (10, Reference by unit. Order
20, 30...) multiples of 10 (10, 20, 30...)
References
NSYFB45 NSYETF NSYEDCO NSYEDCOC DZ5MS10
PB500829-33
PB500831-34
PB500830-37
PB500830
PB502727-68
Telequick Telequick
PB501851-10
PB501847-15
251
Accessories Mounting
Cross rails and profiles for floor-standing
enclosures
In the Spacial SF, SM, SFX and SMX enclosures, it is possible to create a mounting
SM SF SD at any point of the inner volume, providing mounting planes with different widths,
Telequick heights and depths.
SMX SFX SDX In the case of the Spacial SM, it may be necessary to install vertical/horizontal
adaptation profiles and 40-mm universal cross rails (1 row).
Combination examples
in vertical position.
252
Accessories Mounting
Cross rails and profiles for floor-standing
enclosures
Combination examples
PB500838-26
to the structure, quickly and easily.
bb Spacial SF and SFX*:
vv They clip onto the structure and are fixed by M6
self-tapping screws, or optionally with M6 caged
nuts.
bb Spacial SM:
vv Possibility of clipping onto the adaptation profile
or another cross rail.
vv Mounting by means of M6 self-tapping screws.
vv Mounting by means of M6 caged nuts.
253
Accessories Mounting
Cross rails for floor-standing enclosures
PB500846-45
PB500847-45
PB500848-35
SM SF SD
Telequick
SMX SFX SDX
Ø 5.2 11 x 13 27
40
25 20
Dn-93
Ø 5.2 27
11 x 13
25
65
25 20
Dn-93 27
Ø 5.2 11 Ø 13
90
50
25 20
Other dimensions
bb For assembly in other positions, and between cross rails.
bb Material: zinc-coated steel.
bb Thickness: 15/10e mm.
bb Supply: 2 universal cross rails, 4 supports for universal cross rails and mounting elements.
H or W or D (mm) Maximum load (kg) References
by rail 40 mm (1 row) 90 mm (3 rows)
700 50 NSYSUCR4070 -
110 - NSYSUCR9070
900 40 NSYSUCR4090 -
100 - NSYSUCR9090
1100 30 NSYSUCR40110 -
70 - NSYSUCR90110
(2) Cross rails only for mounting cables.
254
Accessories Mounting
PB500850-34 Cross rails for floor-standing enclosures
PB500851-30
PB500852-30
Quick-mounting cross rails
bb Perforated with a pitch of 25 mm (Ø 5.2 mm).
bb Spacial SF: they are fixed directly to the structure, quickly and safely. Clip-on plus screwing.
bb Spacial SM: cross rails for depthwise mounting by means of adaptation profiles and 40 mm universal cross rails (1 row), or between cross rails in any other
position.
Zinc-coated steel
-
Two quick-mounting cross rails and mounting elements
27
Ø 5.2 11 x 13
40
25
Dn-90
Ø 5.2 11 x 13 27
65
25
Dn-90
27
Ø 5.2 11 x 13
90
25
255
Accessories Mounting
Cross rails for floor-standing enclosures
SM SF SFX
PB500853-37
Characteristics Light cross rails
bb Spacial SF and SFX: direct mounting to the structure or between cross rails.
bb Spacial SM: mounting by means of adaptation profiles and 40 mm universal cross rails (1
row), or between cross rails in any other position.
bb Adjustable with a pitch of 25 mm.
bb The light cross rails are equipped with a row of drill holes with a diameter of 5.2 mm and
a pitch of 25 mm, which allows mounting with an M6 self-tapping screw, ref. NSYST30M6S.
Material Zinc-coated steel
Thickness -
Supply Two light cross rails and mounting elements
Width/Depth (mm) References
400 NSYSLCR40
500 NSYSLCR50
600 NSYSLCR60
800 NSYSLCR80
Depth (mm)
400 -
500 -
600 -
800 -
Dn-90
DB300333EN-49
Ø 5.2 18.6
18
25
PB500854-35
256
Accessories Mounting
Cross rails for floor-standing enclosures
SF SF
PB500855-29
PB500861-35
PB500862-34
Rails for heavy loads Cross rail for Lütze chassis Support for Lütze chassis
bb They can be mounted with a cable-gland plate or Cross rail for mounting and adjusting the depth Support for installing Lütze chassis in the back
with a previously mounted mounting plate. of the Lütze chassis. of the enclosure.
bb Laterally adjustable with a pitch of 25 mm.
bb Elongated holes, for adjusting the centre-to-centre
distance of the switchgear.
- - -
- - -
- - -
- - - 75
31
Maximum load (kg) References References Reference
575 NSYHLCR40 NSYLCR40 NSYLSUP
525 NSYHLCR50 NSYLCR50
35
500 NSYHLCR60 NSYLCR60
475 NSYHLCR80 -
8.5 25 29 75
DB300334EN-49
DB300335EN-25
11
6.5
10
10
31
35
25
45
C-50
25
25
35 Ø 8.5 21 29
10
10
25
25
Ø 8.5 21 29
257
Accessories Mounting
Profiles for floor-standing enclosures
PB500478-8
SM
PB500844-8
Characteristics Vertical adaptation profiles Horizontal adaptation profiles
bb The vertical adaptation profiles provide mounting points bb The horizontal adaptation profiles provide mounting points
at the entrance to the enclosure. at the entrance to the enclosure.
bb Mounting on the screws of the hinge and catches of the lock.
bb Allows the depthwise mounting of cross rails, etc.
Material Zinc-coated steel Zinc-coated steel
Thickness 15/10e mm 15/10e mm
Supply 2 vertical adaptation profiles and mounting screws 2 horizontal adaptation profiles and mounting screws
Dimensions (mm) References
Height (A)
1200 NSYSMVR12 -
1400 NSYSMVR14 -
1600 NSYSMVR16 -
1800 NSYSMVR18 -
2000 NSYSMVR20 -
Width (B)
600 - NSYSMHR6
800 - NSYSMHR8
1000 - NSYSMHR10
1200 - NSYSMHR12
1600 - NSYSMHR16
24.5 25 25 27.5
DB300325EN-31
DB300326EN-54
15 25 25 11
12.5
13
20
25
42
20
1.5 12.5
12.5
6
Ø 5.2
25 25 28
B-220
25
Ø 5.2
1.5
24.5
42 6
A-94
13
11
25 25
15.5
12.5
PB500843-33
PB500845-34
258
Accessories Mounting
Trays
PB500523-44
PB500669-42
SM SF
sliding trays.
bb Material: polyamide 6 (black).
bb Supply: 2 units & mounting elements.
Reference
NSY1TH
PB500672-34
259
Accessories Mounting
Rails
SM SF SD
Telequick Telequick
SMX SFX SDX
S3D S3X PLM
PB500222-33
PB500865-36
PB500868-45
PB500773-31
B B B
DB300337EN-85
DB300336EN-69
DB300339EN-70
DB300341EN-72
15
1.5 7.2
35
50 20 50 15
50 10
5.5
1
13.5
9
5
Ø7
5.5
1.5 B
7
37
1 1.5
35
35
16.5
1.5
35
15 1.5
7
32
35
1 1 20
10 15 10 Type W
Type A 15
B
NSYADR60
DB300338EN-70
B 2000 NSYSDR60 15 10
7.2
Ø7
10
25 7.2
5
37
1.5
35
1
35
7.2
7
1 20 50
Type B
Type F 2000
15 10
* For wall-mounting enclosure. ** For floor-standing enclosure.
Ø7
1.5
35
1
25 25
2000
260
Accessories Mounting
Rails
PB500870-45
PB500872-29
DB300342-79
J 2000
25 Ø 11 F
E
G
20
40
D
A
C
25 50 H F
PB500871-16
261
Accessories Mounting
2000 mm rails
PB500864-36
PB500867-37
PB500869-42
Telequick
Ø7
Length (mm) Perforations Material Type Supply References References References
1.5
37
35
2000 Perforated Galvanized steel A 20 NSYSDR200D NSYADR200D NSYDPR200D
1 20
2000
B 20 NSYSDR200BD NSYDPR200T*
Not perforated 15
Galvanized steel 7.2 A 20 NSYSDR200 NSYADR200 NSYDPR200 B
5.5
15 10
5
B 20 NSYSDR200B
Ø7
1.5 1
35
35
1.5
37
Zinc-coated steel C 6 AM1DL201
35
1
1
Aluminium D 10 AM1EA200 20 50
2000 2000
DB300340EN-70
DB300341EN-68
2000 2000
9 25 7.2 15 10
DB300337EN-73
7.2
Ø7
15 25 7.2
5.5
7.2
5
1.5
37
35
7.2
1.5 1 32
1.5
35
35
1
16.5
25 25
1
15 2000
Type A Type B
25 2000 2000
DB300750-29
25 7.2
75
50
7.2
3 2000
Type C
1
DB300751EN-30
1.8
22
35
38
15.9 2000
Type D
* 10/10e mm thickness.
262
Accessories Mounting
Rail accessories
PB500818
PB500863
PB500863
PB500866
PB500886
NSYSNSM6
NSYSNM6 NSYSNSM8
NSYSNM8
Characteristics Nuts
For symmetric rails For symmetric rails For asymmetric For double-profile For serrated C-shaped
2000 mm version DIN rails, 2000 mm DIN rails rails
version
Clip-on nut. Clip-on nut. Quarter-turn sliding nut. Quarter-turn sliding nut. Quarter-turn sliding nuts.
Only for types A and B.
Supply 100 100 100 100 10
Type References
M3 - - - AF1CF34 - -
M4 AF1GC4 AF1GC4 DZ5ME5 AF1CF34 - -
M5 AF1GC5 AF1GC5 DZ5ME8 AF1CF56 - -
M6 AF1GC6 AF1GC6 DZ5ME9 AF1CF56 NSYSNM6 NSYSNSM6
M8 - - - - NSYSNM8 NSYSNSM8
263
Accessories Mounting
Connectors for symmetric C-shaped rails
bb The connectors enable the formation of chassis or frames and structures for
Examples mounting switchgear, in any position inside the enclosures, allowing the mounting of
DIN rails or other elements.
Combinations with connectors bb See symmetric C-shaped rails.
for symmetric C-shaped rails
PB500509-73
PB500877-33
PB500875-40
PB500876-38
Characteristics EMA connectors EVA connectors UCA connectors
To joint two symmetric To join two symmetric To join symmetric C-shaped
C-shaped rails, C20 and C40 C-shaped rails, C20 and C40 rails, types C20 and C40,
types, at right angles; they can types, forming an overlapping forming a cross-shaped
also be used to obtain a assembly with plane change, assembly of three rails located
T-shaped assembly. or also at right angles on the same plane, for
for the formation of spacers or example inside a frame.
supports at a different level.
DB300346-30
DB300347-45
A
B
A
D
D
E
E D
A
B C F G
A C
E
B
F
C
A
D
E
F G
C
264
Accessories Mounting
PB500878-31 Connectors for symmetric C-shaped rails
PB500879-34
PB500880-29
PB500881-33
PB500883-28
UTA connectors ECA connectors UR connectors UT connectors EN connectors
bb To create a T-shaped bb To form a cross-shaped bb For rectilinear joining of To form T-shaped To create L-shaped assemblies with plane
assembly between two assembly with two symmetric C-shaped rails. assemblies between change in the symmetric C-shaped rails,
symmetric C-shaped rails, symmetric C-shaped rails, bb Recommended when the symmetric C-shaped rails. between them or with any other section.
C20 and C40 types, C20 and C40 types, located standard length is not They are used to form
especially recommended perpendicularly on different sufficient or for maximising crossbars on frames and
for forming crossbars on planes. fractions. structures.
chassis and frames. bb The ECA42 connector
bb The UTA42 connectors type makes it possible to
type allows C20 rails to be join C20 rails with C40 rails.
joined with C40 rails.
- - - - -
20 units. 20 units. 20 units. 20 units. 20 units.
References by unit. References by unit. References by unit. References by unit. References by unit.
Order by multiples of Order by multiples of Order by multiples of Order by multiples of Order by multiples of 20 units
20 units (20, 40, 60, etc.) 20 units (20, 40, 60, etc.) 20 units (20, 40, 60, etc.) 20 units (20, 40, 60, etc.) (20, 40, 60, etc.)
DB300349-36
DB300350-28
DB300351-24
DB300352EN-24
DB300353EN-22
DB300354EN-25
10.2
D
28 16
20
40
B ØF
25
21
A
6.2
F
60
10.5
20
B
G
B
C
E
B
F
20
35 21 60 40
G
B
Ø 8.2
C
10.2
C
D 15 60 60
D
A A C D D
E
20 20
20
8.2
F F
D
A
B
A
D D 16 16 14
20
C A 2
10.2
2.5 8.2
E
G 10
E
28 16
21
40
6.2
25
10.5
3 10.2
20
35 21 60 40
28 16
20
15 Ø 8.2 10.2
60
20
8.2
20
20
60 60
16 16 14
20 20
10.2
28 16
265
Accessories Mounting
Spacers
PB500884-53
PB500778-55
M6 14 NSYEX146
M6 16 NSYEX166
M6 18 NSYEX186
M6 20 NSYEX206
M6 30 NSYEX306
M6 40 NSYEX406
M6 50 NSYEX506
M6 100 NSYEX1006
M8 15 NSYEX158
M8 20 NSYEX208 Combination of spacers Minimum Maximum
M8 30 NSYEX308 height (mm) height (mm)
M8 40 NSYEX408 NSYETU48 + NSYETU48 53 64
M8 50 NSYEX508 NSYETU48 + NSYETU58 63 74
M8 60 NSYEX608 NSYETU48 + NSYETU79 85 95
M8 100 NSYEX1008 NSYETU48 + NSYETU118 124 134
NSYETU58 + NSYETU58 73 84
DB300355-61
266
Accessories Mounting
19" Chassis
PB500323-26
S3D S3X
PB500322-26
Characteristics 19" fixed chassis for 19" swing chassis for
wall-mounting enclosure wall-mounting enclosure
bb 19" fixed chassis comprising 2 19" uprights 19" swing chassis opening to 120° with closure
with mounting. by 3 mm double bar insert.
bb Adjustable in depth by mounting on the step
slides in accessories.
Material Galvanized steel Steel
Finish - Textured epoxy-polyester powder paint
Colour - RAL 7035 grey
Thickness 20/10e mm -
Maximum load 3 kg per unit 3 kg per unit
Enclosure (mm) Unit number References Unit number References
Height Width
400 600 8 NSYVDM8UF 7 NSYVDM7UP
600 600 12 NSYVDM12UF 11 NSYVDM11UP
800 600 17 NSYVDM17UF 16 NSYVDM16UP
1000 600 21 NSYVDM21UF 20 NSYVDM20UP
800 - - 20 NSYVDM20U8P
1200 800 - - 25 NSYVDM25U8P
267
Accessories Mounting
Nuts and screws overview
PB500871-16
PB500871-16
PB501768-9
PB501813-13
Characteristics Clip-on nuts Combiplas slide nut Screws with captive washer
Hexagonal head
Usage For Telequick C - shaped rail - 20/40/60 mm All nuts
mounting plates
PB500107
PB500870-46
PB501763-11
PB501766-12
PB501764-11
Type Supply References Rail Combiplas nut Metal sliding nut Models Supply References
type
Supply References Supply References
M3 100 AF1EA3 - - - - - - - -
M4 100 AF1EA4 C20 100 NSYBN204 100 NSYB204 M4 x 10 mm 100 AF1VA410
C40 100 NSYBN404 100 NSYB404 M4 x 16 mm 100 AF1VA416
M5 100 AF1EA5 - - - - - M5 x 12 mm 100 AF1VA512
M5 x 18 mm 100 AF1VA518
M6 100 AF1EA6 C20 100 NSYBN206 - - M6 x 12 mm 100 AF1VA612
C40 100 NSYBN406 - - M6 x 18 mm 100 AF1VA618
C60 100 NSYBN606 100 NSYB406
M8 - - C40 100 NSYBN408 - - M8 x 20 mm 100 AF1VC820
C60 100 NSYBN608
M10 - - C60 100 NSYBN610 - - - - -
References by unit. Order by multiples of the units specified in the supply.
PB500818-31
PB500823-43
PB500819-15
Serrated
1/4 turn 1/4 turn
Fixing brackets Removable nut
Characteristics Mountings and nuts for serrated uprights
Type Mounting brackets 1/4 turn Serrated 1/4 turn Removable nut Cage nut
Supply Ref. Supply Ref. Ref. Supply Ref. Supply Ref.
M4 4 NSYMFB - - - - - - -
M5 - - - - - - -
M6 10 NSYSNM6 NSYSNSM6 50 NSYCNM6 50 NSYCNFM6
M8 10 NSYSNM8 NSYSNSM8 50 NSYCNM8 50 NSYCNFM8
- - - - - - - -
268
Accessories Mounting
Nuts and screws overview
PB501855-10
PB500856-19
PB501859-10
PB501766-17
Torx screws Self-tapping screw Mountings and nuts for aluminium uprights
PB500108-28
PB500105-29
Models Supply References Models Supply References Sliding nuts Brass nuts to fix the upright
to the enclosures
Supply References Supply Reference
- - - - - - - - 4 NSYAMCSF
- - - - - - 100 NSYNM4
- - - - - - - -
PB500863-25
PB500886-24
PB500866-24
PB500817-22
Flat nuts Clip nut Quarter turn nut Quarter turn nut
for standard uprights for symmetric DIN rail for double profile DIN rail for asymmetric DIN rail
2 x standard mounting uprights 35 x 15 mm symmetric DIN rail 35 mm double profile DIN rail 35 mm asymmetric DIN rail
for floor-standing enclosures
PB500222-45
PB500868-59
PB500865-54
PB500482-26
269
Accessories Cable management
Cable entries overview
PB500024-33
PB500023-21
PB501865-18
PB501700-18
Characteristics Flexicable Multi-A Multi-C Multi-R
Full membrane cable gland FL13 & FL21 type membranes. Circular connector-free entries. Rectangular connector-free
plate. entries.
References*
See page 278 278 279 279
* For details, type the reference in the search engine of www.schneider-electric.com.
(1) "Pop-out" membranes only.
270
Accessories Cable management
Cable entries overview
PB500945-17
PB500106-31
PB502492-17
PB500944-17
Multi-T Multi-F Multi-CR Multi-H
FL21-type membranes. FL13 & FL21 pre-configured Cable entries with dies for FL21 insulated flange with
flanges. cables equipped with ISO knockouts.
connectors.
Insulating material Fibreglass-reinforced - Polycarbonate, glass-fiber
polypropylene and TPE - reinforced
Halogen Free
RAL 7035 RAL 7035 - RAL 7035
Hard plastic
No No Yes, cable die NSYDCE●●● Yes
and NSYDCE●●●●
On cable gland plate adapter On cable gland plate adapter On cable gland plate adapter On cable gland plate adapter
or directly on enclosure or directly on enclosure or directly on enclosure or directly on enclosure
No No Yes No
271
Accessories Cable management
Cable entries overview
PB500975-16
PB500976-11
PB500099-9
PB500267-10
PB500266-52
272
Accessories Cable management
Cable entries overview
PB500269-23
PB500270-19
PB500268-17
273
Accessories Cable management
Cable entries
PB502701-58
Multiple Single bb Flexibility of installation: for high flexibility, the multiple cable entry is
the right choice.
PB502703
PB502704
PB502705
Push the membrane into Make a small hole in Push the cable or tube Pull the cable or tube back
a standard hole. the membrane. through the guide hole. some 20 mm to lock it.
bb Hard plastic needs specific tools to create the opening (drill or knife) but, thanks
to the cable gland, offers a very high retention force. Another use of this solution is
for public places, since the hard surface prevents objects being pushed in.
bb Combined: the material of the cable entry plate is hard plastic, but the cable is
pushed through a soft membrane. In this case you have the advantages both of soft
membranes (easy and fast installation, flexibility) and hard plastic membranes
(high retention force, when using specific cable clamps).
PB502707-70
PB501702
PB501703-30
PB501704-35
bb Some multiple cable entries require a cable gland to be able to retain the cables
and ensure the degree of protection.
274
Accessories Cable management
Cable entries
4 - Installation possibilities
There are 4 ways to install your cable entries on the enclosure:
bb By replacing the cable gland plate: the standard cable gland plate of your S3D
PB500305-30
bb On modified cable gland plate: the standard cable gland plate is unscrewed and
PB500023-35
bb On cable gland plate adapter: this plate, which has the outer dimensions of a
PB500462-44
standard cable gland plate, has one or more pre-cut cut-outs of standard dimensions
(FL13 and FL21).
On steel wall-mounting enclosures, the plate can replace the standard cable gland
plate once the cable entry is fitted into it. On polyester enclosures, a cut-out must be
created. Schneider Electric provides this service: a precise laser cut-out is factory-
created upon request.
PB500599-37
On steel floor-standing enclosures, you may either use the specific cable gland roof
or create a cut-out (see expert’s tip 1, page 277).
PB500604-15
DB300718-15
NSYTL●FL NSYTL●2FL - NSYTLG4FL
Spacial SF
PB502708-10
PB502709-12
PB500597-15
Zoom on…
FL13 and FL21 are standard cut-out dimensions frequently used
in northern European countries and also used by our enclosures
for several years now.
275
Accessories Cable management
Cable entries
PB500946-35
vv quantity
vv diameter
vv position
(see expert’s tip 2, page 277)
bb Medium flexibility:
vv the amount, diameter or position of cables can be changed to a limited extent.
Full flexibility Medium flexibility bb Low flexibility:
vv it is not possible to change the above parameters.
6 - Reversibility
bb Full reversibility: this means that cables can be added/ removed easily
without losing their initial characteristics, such as water tightness.
bb Medium reversibility: for soft membranes, once the cable has been removed,
there may be a loss of IP depending on the size of the cable and the cut. For hard
plastic entries or combined material entries, initial characteristics are regained by
adding plugs.
bb Low reversibility: the cable entry must be completely replaced in order to regain
the initial characteristics.
8 - Cable retention
Choose the right level of cable retention according to your needs. For locations
accessible to the public, preferably choose a high level of cable retention.
9 - Cable diameter
Choose the cable entry seal according to the cable diameter.
Take into account cable diameter tolerances.
Ø 15.9
Ø 5.5
DB300404-42
DB300406-41
Ø 5.5
Ø 6.5 Ø 9.2 Ø 6.5
276
Accessories Cable management
Cable entries
PB502712-31
a given surface
For some installations, a large quantity of cables must go through the cable entry.
Some cable entries can receive a high density of cables, which can result in more
economical installation (fewer cable entries to be bought).
For small enclosures, it may simply be impossible to install too many cable entries
due to the available space on the enclosure’s wall (see expert’s tip 3, page 277).
Some cables have large connectors which cannot be pushed through tight cable
clamps or cable seals.
These cable entries have the unique advantage of not requiring the cable to be cut,
thanks to the snap-fitting system.
PB502714
DB300410
DB300410
PB502715
A high cable retention force is provided thanks to the integrated cable fastener.
Expert’s tip
1 Some cable entries require cut-outs to be 2 Installing a cable entry with full flexibility is the
machined on the enclosure or cable gland plate. solution when a large series of enclosures is being
Our customized offer provides this service. prepared for different types of installations.
The quality of your enclosure will therefore be By using one combination of enclosure-cable entry,
guaranteed since the painting operation is performed you can cover a large variety of installations!
Configured after creating the cut-outs.
Specific
3 When the cable entry has been defined, the next 4 When your environment requires a high level
step is cable management inside the enclosure. For of IP for your installation, make sure you have an
correct thermal management, all wires must be fitted appropriate thermal management system to avoid
and attached so as not to create an obstacle for condensation or overheating problems.
correct air flow. Consult our Thermal Management offer in our
Consult our Universal Enclosures catalogue for cable Universal Enclosures catalogue and our Control
management accessories (such as cable ducts) and Panel Technical Guide related to this issue.
consumables (such as cable ties).
PB502716-53
PB502717-50
PB500966-50
PB500965-44
277
Accessories Cable management
Cable entries
Dimensions
PB501695-34
FL 13
PB501865-38
PB501696-34
FL 21
PB501697-34
PB501698-35
PB502035-26
NSYAECPFLA7 NSYAECPFLA10
Mount FlexiCable on Create a hole with Push the cable through
PB501699-35
PB501700-35
NSYAECPFLA25 NSYAECPFLA33
278
Accessories Cable management
Cable entries
Dimensions
PB500024-57
PB500023-56
DB300396-38
Multi-C Multi-R
270 270
10 units. Reference by unit. Order by multiples of 10 (10, 20, 30...) 1 unit
No. of Dimensions/ Diameter of the cable entry (Ø mm) References No. of Dimensions/ Diameter of the cable entry (Ø mm) References
openings cut-out Ø openings cut-out Ø
3-5.5 3-6.5 3.6-6.5 5-9.2 6-10 9.6-15.9 4.3-8.1 3-6.5 5-9.2 8-12.5 9.6-15.9
4 50.5 - - - - 3 1 NSYTSAM504SE 14 112 x 36 - 6 4 - - NSYTSA2414SE
8 50.5 - - 7 - 1 - NSYTSAM508SE 17 112 x 36 - - 17 - - NSYTSA2417SE
8 63.5 - 2 - 4 - 2 NSYTSAM638SE 22 112 x 36 - 16 4 2 - NSYTSA2422SE
13 63.5 6 - 6 - 1 - NSYTSAM6313SE 23 112 x 36 23 - - - - NSYTSA2423SE
29 112 x 36 - 29 - - - NSYTSA2429SE
112 Ø 5.5
DB300399EN-65
DB300397-53
Ø 63.5
32
36
DB300398-53
Ø 50.5
9
2
Ø 15.9
DB300404EN-40
DB300407EN-37
Ø 6.5
Ø 5.5
Ø 9.2
NSYTSAM504SE
KDP/R M50 / 4
Ø 9.2 Ø 13 Ø 5.5
DB300401-12
Ø 6.5
NSYTSA2414SE NSYTSA2422SE
KDP 24/14
KDP 24/22
DB300408EN-36
DB300405EN-35
NSYTSAM508SE
KDP/R M50 / 8
DB300402-12
NSYTSAM638SE
KDP/R M63 / 8
DB300403-12
Ø 6.5 Ø 5.5
NSYTSA2429SE
KDP 24/29
NSYTSAM6313SE
KDP/R M63 / 13
279
Accessories Cable management
Cable entries
PB502492-40
Dimensions
PB500944-38
Characteristics Multi-T Multi-H
See page 271 271
Supply - -
No. of Diameter of the cable entry (Ø mm) References Dimensions (mm) Reference
cable
entries
5-7 6-10 8-12 8-16 10-14 12-18 14-20 17-32 20-26 24-54 30-60 L1 L2 H
DB300393-50
DB300813-50
DB30081450-50
DB300390-48
(1)
194
214
194
214
194
214
194
62.5
62 62 62
88 88 88 M16 or M25
NSYAECPFLBP NSYAECPFLT7 NSYAECPFLT25 NSYAECPFLT35 M12
M12 or M20
* Metallic plate.
280
Accessories Cable management
Cable entries
Dimensions
PB500949-35
PB500945-49
PB500950-30
NSYDCE240
NSYDCE244
PB500951-29
NSYDCE2410
Multi-F Multi-CR
271 271
- 1 die and mounting elements
Dimensions (mm) Diameter of the cable entry (Ø mm) References Connector Number of cable References
cut-out type entries
130 (103*)
DB300409EN-60
112 (91*)
36
32
Ø 5.5
* Cut-out for reference NSYDCE16●●●.
281
Accessories Cable management
Cable entries
Dimensions
DB300735-19
DB300734-40
DB300733-24
DB300736-30
Characteristics Prisma
Type FL21 225 x 137 mm opening
Plain Pre-drilled Membrane Pre-drilled
Solid cable-gland Suitable for receiving cable Membrane to be drilled according to the required Suitable for receiving cable
plates. glands with metric pitch. diameter. glands with metric pitch.
See page 271
Reference References No. Amount Cable diameter Ref. References
entries of entries comprised between
per Ø
Min. Max.
08881 2 x M20 or M32 08892 2 2 28 60 08897 With 39 entries 08898*
+ 2 x M25 or M40 from 7 to 26
5 x M16 or M25 08895 With 2 entries 08899
+ 8 x M20 from 33 to 72
* Reference 08898 is made up of:
3 cables with diameters from 14 to 26.
4 cables with diameters from 10 to 20.
32 cables with diameters from 7 to 16.
2 x 30 + 3 x 18 + 5 x 14 mm.
Characteristics Cable clamp for improved cable retention Blanking plugs
Installation on FL 21 membrane type "A" for cable entrance to block cables when bb Installation on FL 21 membrane type "A"
installed. It can be easily removed. for cable entrance to fill the opening used.
bb Set of 2 plugs for diameter 30 mm, 3 plugs
for diameter 18 mm and 5 plugs for diameter
14 mm.
Material PA6 - halogen free LDPE - halogen free
Installation 1. Push the cable through the membrane entrance to the desired position -
2. Put the cable clamp around the cable and slide it into the cable entry
3. Push the cable clamp fully into the membrane entrance and the cable
will be fixed
Other characteristics Temperature range: -40 to +85°C Temperature range: -30 to +50°C
Cable clamp Membrane Cable Supply References Reference
outer diameter entrance diameter
(mm) diameter (mm) range (mm)
15 14 7-9 Set of 8 NSYAECPFLACA14 NSYAECPFLAP
18 18 9-11 Set of 6 NSYAECPFLACA18
20 18 10-12 Set of 6 NSYAECPFLACA20
30 30 20-23 Set of 3 NSYAECPFLACA30
PB501704-29
PB501703-23
PB501702-20
282
Accessories Cable management
Cable entries
Dimensions
DB300720EN-50
PB500604-54
Ø 3.9
H
I
DB300094EN-68
(3)
DB300094EN-68
Our membrane can be easily adapted to fit onto all our metallic enclosures using the adapter plate.
Application example
283
Accessories Cable management
Cable entries
Dimensions
PB500266-50
PB500975-38
Characteristics Mixed membrane entries PVC adjustable cone-shaped entries
for IP55 direct cable entries
See page 272 272
Supply Minor packaging of 10 pieces -
Ø (mm) References Fig. ØA Ø B* Ø C ØD E F Capacity Supply References
Drill Cable / RAL 9010 RAL 7035 Cable Ø Tube
hole conduit
23 4 - 20 IMT36172 ISM71071 1 25 21.5 18 5 3.2 13 5 to 18 PG 9 to 11 50 NSYECPC3
29 4 - 25 IMT36173 ISM71072 33 29.5 26 5 3.2 20 5 to 26 PG 9 to 16 25 NSYECPC5
36 4 - 32 - ISM71073 43 38.5 36 5 3.2 22 5 to 36 PG 9 to 21 25 NSYECPC6
44 4 - 40 - ISM71074 2 70 63 60 28 3 20 28 to 60 PG 21 to 48 10 NSYECPC9
98 90 87 28 3 23 28 to 87 PG 21 to 48 10 NSYECPC15
DB300411-119
E
DB300426-55
E
ØD
Ø B*
Ø B*
ØD
ØC
ØC
ØA
ØA
F
Fig. 1 Fig. 2
TD
284
Accessories Cable management
Cable entries
Dimensions
PB500267-70
PB500976-37
IP67 quick cable entries PVC adjustable cone-shaped entries
272 272
- -
ISO Ø (mm) Supply References ØA Ø B* ØC ØD E F Capacity Supply References
Drill Cable Cable Ø Tube
hole
M12 12.5 3-5 50 IMT36179 25 19.5 16 3 1.2 21 3 to 16 PG 9 50 NSYEC1
M16 16 5-7 50 IMT36180 6 1.2 21 6 to 16 PG 11 50 NSYEC2
M20 20.3 7 - 10 50 IMT36181 27 21.5 18 7 1.2 23 7 to 18 PG 13.5 50 NSYEC3
M25 25.3 10 - 14 50 IMT36182 29.5 23.5 20 8 1.2 26 8 to 20 PG 16 25 NSYEC4
M32 32.4 14 - 20 50 IMT36183 35 29.5 26 10 1.2 27 10 to 26 PG 21 25 NSYEC5
M40 40.7 20 - 26 25 IMT36184 42 38.5 35 12 1.5 30 12 to 35 PG 29 25 NSYEC6
M50 50.7 26 - 35 25 IMT36185 52 48.5 44 13 1.5 30 13 to 44 PG 36 25 NSYEC7
DB300413-53
DB300427-49
E
Ø B*
ØC
ØD
ØA
285
Accessories Cable management
Cable holding
PB500969-41
PB500971-32
SM SF SMX SFX
PB500967-39
PB500968-36
PB500970-42
Characteristics Lower cable-guide Cable-guide cross-rails L-rail for mounting Door cable-guide
cross-rail for framework cables cross-rail
bb It allows quick mounting of Support types: bb Rail for mounting cables bb Recommended for mounting
cables entering and exiting bb Angle support at 90°: entering from the bottom. cables in the internal equipment
the enclosure. for vertical cable mounting. bb Adjustable depth with a pitch of the door.
bb Depth adjustable every bb Angle support at 120°: of 25 mm. bb Height adjustable every
25 mm. for mounting cables near the bb It is not possible to mount it on 25 mm.
cable entry. a plinth cross rail.
Material Galvanised steel Zinc-coated steel Zinc-coated steel Zinc-coated steel
Mounting bb Spacial SF: for suitable bb Spacial SF and SFX: support bb Spacial SF and SFX: bb Direct mounting on the
enclosures with widths of 1200 for direct mounting on the mounting reinforcement frame
and 1600 mm, use the adaptation framework, cross-rails or rails to the bottom frame, above the
kit for 2-door suitable enclosures, bb Spacial SM: mounting on the cable entry, or else to the plinth,
see page 249 bottom mounting rail, using the plinth cross rails,
bb Spacial SM: for floor-standing or on the floor-standing enclosure see page 103
enclosures with a width of by means of adaptation rails and bb Spacial SM and SMX:
1200 mm, a top/bottom mounting 40 mm universal cross-rails mounting to the bottom
rail installed in central position (1 row) in vertical position adjustment rails, above the cable
is required bb Spacial SMX: mounting on the entry, or else to the plinth, using
bb Spacial SFX: no adaptation bottom mounting rail and 40 mm the plinth cross rails, see page
piece is required for the 1200 mm universal cross-rails (1 row) in 103
suitable enclosures vertical position bb The cables are fixed to the rail
bb Spacial SMX: no adaptation by means of metal clamps
piece is required for the 1600 mm
floor-standing enclosures
Supply 1 cable-guide cross-rail and 2 supports and mounting One rail, two mounting supports 2 cable-guide cross-rails and
mounting elements elements and mounting elements mounting elements
Dimensions (mm) References
Width (B) Support angle
500 - - - - NSYSDGCR5
600 NSYCFP60 90° NSYCFS96 NSYFCG60 NSYSDGCR6
120° NSYCFS126
800 NSYCFP80 90° NSYCFS98 NSYFCG80 NSYSDGCR8
120° NSYCFS128
1000 NSYCFP100 - - NSYFCG100 NSYSDGCR10
1200 2 x NSYCFP60 - - NSYFCG120 -
1600 2 x NSYCFP80 - - NSYFCG160 -
10 16
DB300421-43
DB300422-72
DB300419-44
5
25
10
10
Ø5
7
15
B-130
B-150
B-175
B-50
B-10
B-70
B-50
13
30
7
10
16
40
40
286
Accessories Cable management
Cable holding
S3D S3X
PB500966-46
PB500333-37
Characteristics Plastic cable support Door cable-guide cross-rails
for wall-mounting enclosures
It clips or screws onto 35 mm symmetric rails or a C-shaped rail. bb They are installed on wall-mounting enclosures with
heights from 400 mm for Spacial S3D and 500 mm
for Spacial S3X.
bb They make it easy to equip the inside of the door.
bb Installation cable ties, see page 288.
Mounting Quick and easy mounting of cables using cable ties bb They are fixed to the door reinforcement frame
by 2 self-tapping screws. The angle can be directed towards
the body of the enclosure or towards the door
Supply 10 units. Reference by unit. 2 cable-guide cross-rails and mounting elements
Order by multiples of 10 (10, 20, 30...)
Dimensions (mm) Support dimensions Maximum no. References Door dimensions (mm) References
(mm) of cables
Width Width
75 5 NSYSCCDINLG75 400 NSYTFPCRN4
140 9 NSYSCCDINLG140 500 NSYTFPCRN5
600 NSYTFPCRN6
800 NSYTFPCRN8
1000 NSYTFPCRN10
11
DB300418EN-59
DB300420-25
63 127.5
9
40
40
12
13.5
139.5
287
Accessories Cable management
Cable ties
Identification ties
Identification tie with marker for safe and fast clamping of cables, conduits and tubing. Delivered in a sealed packaging to ensure
performance, irrespective of storage conditions.
bb Material: PA 6.6.
P121326
Max. clamping (mm) Colour Length (mm) Qty per package References
Marker size 20 x 9 mm, width 2.5 mm
P121329
Accessories
For max. tie width Colour Dimensions Qty per package References
(mm) H x W x D (mm)
Self-adhesive bases
P121327
Self-adhesive base for the mounting of cable ties. The base for max. tie width 4.8 mm is both self-adhesive and has an additional
screw-fix option.
bb Material: PA 6.6.
P121325
Cradle for the mounting of cable ties. Fixed with screw or rivet.
bb Material: PA 6.6.
7.8 Clear 22.2 x 15.9 x 9.7 100 ENN46109
Cable tie pincers
Pincers intended to facilitate tightening and cutting of 6 and 9 mm installation ties.
bb Material: steel.
6 to 9 - - 1 ENN46150
288
Accessories Cable management
Ducts
PB500965-37
PB500774-35
PB500961-29
PB500962-22
Characteristics Corrugated cable tube Spiral cable duct Lyre-shaped clamps Steel wired cable
tray
bb Corrugated tube allowing cable bb Spiral strip for bundling cables. Clip-on clamps designed for Mounting on the cable
entry between the structure and bb Allows cables to enter between the direct installation on the 19" supports.
the door. body and the door. racks, Telequick mounting Dimensions (2 types):
bb Free from halogens and heavy plates and symmetric bb 1845 x 200 x 35 mm.
metals. DIN rails. bb 1845 x 200 x 54 mm.
bb UV protection.
Material Low-density polyethylene (LDPE) - - Zinc-coated steel wire
Colour Black Colourless Black -
Supply One 25 m reel One 50 m reel 10 units. Reference by unit. 1 vertical steel wired
Order by multiples of 10 cable tray and mounting
(10, 20, 30...) elements
Ø (mm) References Tightening Ø (mm) References Use References Necessary References
range (mm) depth (mm)
Nominal Inner Outer Inner Outer
17 16.6 21.2 NSYCPT17 12 to 100 9 12 NSYTC12100 For Telequick AK2LA39 35 NSYBPC3
mounting plates
29 29 34.5 NSYCPT29 and 19" racks 54 NSYBPC5
37 36 42.4 NSYCPT37 For symmetric AK2LD01
DIN rail 90 x
50 47.7 54.5 NSYCPT50 2.5 mm cables
For symmetric AK2LD02
DIN rail 75 x
2.5 mm cables
289
Accessories Cable management
Ducts
PB501863-50
PB501810-50
Characteristics Cable-duct
With lateral through slots and rear perforations.
Material Rigid PVC
Colour RAL 7030 grey or RAL 5000 blue
Standards Compliance with standards VDE 0660/506 and DIN 43659
Other characteristics bb Temperature resistance: -5 ... +60°C
bb Behaviour in fire: material V0 according to UL 94
bb Fire resistance: 960°C according to IEC 60695-2-1/1
bb Maximum capacity of H07.V.K 1.5 mm2 flexible wire (filling factor: 0.6)
Supply 8 units. Supplied in lengths of 2 m
Width (mm) Height (mm) Color References
25 25 Grey AK2GD2525
50 Grey AK2GD2550
30 35 Blue AK2GA33
55 Blue AK2GA35
90 Blue AKEGA39
144 Blue AK2GA315
37.5 50 Grey AK2GD3750
75 Grey AK2GD3775
50 50 Grey AK2GD5050
75 Grey AK2GD5075
60 55 Blue AK2GA65
90 Blue AK2GA69
144 Blue AK2GA615
75 50 Grey AK2GD7550
75 Grey AK2GD7575
100 75 Grey AK2GD10075
125 75 Grey AK2GD12575
Cable-duct accessories
S3D SM SF S3X SM SF SD SMX
PB500957-47
PB500956-26
Supply 50 units. Reference by unit. 10 units. Reference by unit. 10 units. Reference by unit.
Order by multiples of 50 Order by multiples of 10 (10, 20, 30...) Order by multiples of 10 (10, 20, 30...)
(50, 100, 150...)
References
NSYCDRB NSYSPCP NSYCDS
DB300415EN-29
DB300416EN-44
20
25
45° Ø 6.5
60
55
67.5
100
1.5
19 33 12
34
11.5 30
290
Accessories Cable management
PB501811-49 Ducts
PB501812-41
Covers for cable-duct
Replacement covers.
Rigid PVC
RAL 7030 grey or RAL 5000 blue
Compliance with standards VDE 0660/506 and DIN 43659
bb Temperature resistance: -5 ... +60°C
bb Behaviour in fire: material V0 according to UL 94
bb Fire resistance: 960°C according to IEC 60695-2-1/1
bb Maximum capacity of H07.V.K 1.5 mm2 flexible wire (filling factor: 0.6)
8 unit. Supplied in lengths of 2 m
AK2CD25
AK2CA3
AK2CD37
AK2CD50
AK2CA6
AK2CD75
AK2CD100
AK2CD125
PB500775-40
PB500959-50
PB500960-40
bb Clips onto the Telequick mounting plate or In transparent plastic, clipping onto the slats of the bb M5 x 10 mm slotted hexagonal head.
the 35 mm DIN rail. cable ducts. bb Respects electrical insulation.
bb Includes a bolt for mounting the cable ducts
through the 6.5 x 14 mm drill holes made in the back.
bb The 2 functions, clipping and bolting, provide
considerable time savings.
bb Respects electrical insulation.
Black polyamide. Behaviour in fire: V0 according Polycarbonate -
to UL 94
20 units. Reference by unit. bb 50 units. Reference by unit. 100 units. Reference by unit.
Order by multiples of 20 (20, 40, 60...) Order by multiples of 50 (50, 100, 150...) Order by multiples of 100 (100, 200, 300...)
bb Paper labels supplied
40
15 24
291
Accessories Lighting and power sockets
Power distribution rails
NSYAPU10F3-40
NSYAPU19F8S-61
Characteristics UTE - 16 A / 230 V~ with pin-earthed outlets
bb Sockets set at 35° with child protection.
bb Aluminium profile silver - heigh 1 U.
bb Equipped with power cord (3G 1.5 mm2) type H05 VVF, equipped with a mould right angle
plug with earthing contact system.
bb Could be used in: France, Belgium, Poland, Monaco, Slovakia, Czech Republic.
292
Accessories Lighting and power sockets
NSYAPU10S3-40 Power distribution rails
NSYAPU19UK6S-61
NSYAPU19S8S-62
NSYAPU10S3 -
NSYAPU10S3S -
NSYAPU19S9 -
NSYAPU19S8S -
NSYAPU19S6CB -
NSYAPU19S7FA -
- NSYAPU19UK7
- NSYAPU19UK6S
NSYAPUS10S -
NSYAPUS12CB -
PB500985-35
PB500984-32
293
Accessories Lighting and power sockets
Lamps
PB501706-64
British NSYLAMCB
40 mm / 1.56”
63 mm / 2.46”
372 mm / 14.51”
4 fixing options
PB501710-40
PB501711-37
PB501714-55
PB501713-40
294
Accessories Lighting and power sockets
Lamps
PB501723-13
PB501716-85
DB300832-27
41.2
78
25 315
325.5
575
66 91.5
* Approximate values.
PB501724-34
Magnetic fixing.
295
Accessories Floor accessories
Casters and feet for floor-standing
enclosures
SM SF SD
PB500578-41
SMX SFX SDX
PB500219-35
Characteristics Transport casters* Enclosure casters
bb Quick installation on plinths with heights of bb Double casters.
100 and 200 mm, except the plinth for bb Height: 92 mm.
enclosure sets. bb Diameter: 64 mm.
bb They can be installed in front or side
position.
bb Clipping and mounting to corner by screws.
bb For use on flat surfaces.
bb Height: 110 mm.
Maximum load 50 kg per castor 100 kg per caster
Supply 4 transport casters (2 with a blocking system) 4 casters and mounting elements
and mounting elements
References
NSYSTW NSYSW
97
DB300446-30
110
Ø 80
SM SF SD
PB501001-25
PB501002-28
296
Accessories Door accessories
Switches and pockets
Switches
S3D S3X SM SF SFX
ISPA011_001-35
ISPA011_010-80
ISPA011_002-40
Characteristics Door switch for wall-mounting Door switch for floor-standing
enclosures enclosures
bb Switch/commutator unit equipped bb The switch is fixed to the structure of
with support and mountings for direct the enclosure.
mounting to the enclosure. bb Drilled M20 cable entry for cable gland.
bb Can be used to control lighting, bb NC + NO contact, 10 A/500 V.
air-conditioning units, etc.
bb It is not compatible with installing the 19"
swing rack and the internal door.
bb NC + NO contact, 10 A/500 V.
Supply 1 door switch and mounting elements 1 door switch and mounting elements
Reference For ranges References
NSYINLCRN SF & SFX NSYDCM20
SM NSYMDCM20
Pockets
SM SF SMX SFX
PB500464-19
PB500485-22
DB300224-38
D-150
A
282
B C
65
297
Accessories Door accessories
Door accessories for floor-standing
enclosures
SM SF SMX SFX SM SF
PB500767-39
PB502559-27
PB500491-31
PB500508-43
PB502558-27
Characteristics Folding support tray Door cross rails Floor-standing door retainer
bb Adjustable horizontal support for bb Direct mounting cross rails bb Door blocker at the opening limit.
laptop computers, documents or any on the profiles of the reinforcement bb It is fixed directly to the front frame of the
other elements. frame of the door. enclosure and to the reinforcement frame
bb Mounting on the door reinforcement bb Adjustable height with a pitch of the door.
frame. of 25 mm. bb It can be installed on doors that open both
bb It can also be mounted on door to the right and to the left.
cross-rails.
bb Height adjustable in steps of 25 mm.
bb In 1000-mm-wide enclosures, any
size can be mounted using door
cross-rail ref. NSYSDCR10.
bb 4 positions: 45°, 60°, 75° and 90°.
Material Steel Galvanised steel -
Finish Painted with epoxy-polyester resin - -
Colour RAL 7035 grey - -
Thickness 15/10e mm 20/10e mm -
Maximum load 30 kg - -
Supply 1 folding support tray and mounting 2 cross rails and bag of mountings Door stop and mounting elements
elements
Dimensions (mm) References
Width (B)
400 - NSYSDCR4 -
500 NSYSDT5 NSYSDCR5 -
600 NSYSDT6 NSYSDCR6 -
800 NSYSDT8 NSYSDCR8 -
1000 - NSYSDCR10 -
Door stop model For enclosures Limit References
Mechanical - - Spacial SF 90º and 120º NSYSFMDR
- - Spacial SM 90º NSYSMDR
Pneumatic - - Spacial SF 120º NSYSFNDR
- - Spacial SM 90º and 120º NSYSMNDR
B-150
DB300223-34
DB300440EN-39
18
25 Ø 5.2
B-200
298
Accessories Door accessories
Door accessories for wall-mounting
enclosures
S3D S3D
PB500223-45
PB500993-40
Characteristics Wall-mounting door retainer
Steel Polyamide
To block the door in the open position. To block the door in the open position.
bb It is installed on enclosures with heights from 400 mm bb It is installed on the perforated rails of the enclosure doors
and widths from 300 mm. at the required height.
bb Earthing connection of the enclosure by means of the bb It is only installed on enclosures with a height of less than
reinforcement rail. 400 mm (no perforated rails).
bb Earthing accessories supplied with the enclosure
(earth-connection wire to be ordered separately),
see page 302.
bb Note: cannot be installed on 19" mounting plates or
on enclosures equipped with internal door.
Material Steel Polyamide 6 (PA6)
References
NSYAEDRSCST NSYAEDRS3DPA6
299
Accessories Door accessories
Windows
PB500996-33
PB500995-23
PB500994-41
DB300442
Fig. 1 Fig. 2
300
Accessories Door accessories
Windows
PB502728-24
PB502001-34
IP55 IP55
1 modular front panel 1 window, mountings and instruction sheet
A B
NSYMW10MK 300 300 NSYCW33
400 400 NSYCW44
500 NSYCW45
600 NSYCW46
500 400 NSYCW54
500 NSYCW55
600 NSYCW56
600 500 NSYCW65
600 NSYCW66
800 600 NSYCW86
DB300831EN
A A
Reference
NSYMW10MR
25
20
B
70.5
77
Note: there are 2 mounting screws for the reference NSYCW86 with 1 without locking
Mounting example
PB500997-39
NSYMW10MK + NSYMW10MR.
301
Accessories Other accessories
Earthing accessories
PB500948-38
SM SF SD SMX SFX SDX
PB500999-18
Characteristics Earthing strip Central earthing point
bb Perforated brass bar, 15 x 3 mm. bb Connects earthing braids and cables
bb 1 m long. to the structure of the enclosure.
bb 87 connection points, M5 drill holes. bb The earth connection is made by means
of the M8 x 18 mm bolt.
Mounting - Mounting to the structure by means of
self-tapping screws
Supply 1 earthing strip and mounting elements 1 central earthing point, elements for mounting
to the structure, and mountings for mounting to
the bolt
References
NSYECB1M153 NSYCEP
S3D S3X
PB501000-42
38
38
27
39
39
28 28
302
Accessories Other accessories
Earthing and paint accessories
PB500217-32
PB500084-42
Characteristics Earth braids Earth cables
Guarantee the earth connection for high Make it easier to install a safe earth
frequencies, avoiding the disturbing electric connection, with a perfect contact,
currents that are produced. with optimised length.
Material Tinned copper Brass and copper alloy terminal, green
and yellow PVC insulating sheath
Supply 10 earth braids (nuts and washers not 10 earth cables (nuts and washers not
included). Reference by unit. included). Reference by unit.
Order by multiples of 10 (10, 20, 30...) Order by multiples of 10 (10, 20, 30...)
Length Width Section Terminal Ø References
(mm) (mm) (mm2) (mm)
130 - 6 6.4 - NSYEL136D6
150 12 6 6.5 NSYEB156D6 -
17 10 6.5 NSYEB1510D6 -
155 17 16 8.5 NSYEB1516D8 -
160 - 6 6.4 - NSYEL166D6
- 6 8.3 - NSYEL166D8
170 - 10 6.4 - NSYEL1710D6
200 27 25 8.5 NSYEB2025D8 -
33 50 8.5 NSYEB2050D8 -
220 - 6 6.4 - NSYEL226D6
- 25 8.3 - NSYEL2225D8
250 - 10 6.4 - NSYEL2510D6
350 - 25 8.3 - NSYEL3525D8
PB501003-37
PB500221-19
303
Applicative and
customised
solutions
304
Envolventes Universales Applicative and customised
solutions
Contents
New 306
Outdoor Heavy Duty enclosures
New 320
Seismic and nuclear enclosures
New 390
Variable speed drive flush-mounting kits
305
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Introduction
Tough
PB502681-34
New PHD: Heavy Duty polyester reinforced with a double
layer of fiberglass. Ultra-resistant, anti-vandalism.
PB502673-29
- pressure and shock resistant Dedicated accessories to resist outdoor,
(IEC 61439-5: 2010), harsh environments: the all-new, slim fanbox
(see page 310 and 312).
- anti-posting thanks to its special
ribbed-surface door,
- insulated (ready to be Class II
according to IEC 61439-1: 2011). Simplicity
PB502648-11
also available.
Fully equipped
PB502662-30
PB502670-29
Anti-vandalism
PB502674-25
See page 396 for details or consult our web site www.schneider-electric.com
306
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Characteristics
PB502646-21
New
PB502665-21
PB502663-21
PB502645-21
PB502653-21
Characteristics Polyester outdoor Heavy Duty enclosures Steel outdoor Heavy Duty enclosures
Wall-mounting enclosure Floor-standing enclosure Wall-mounting enclosure Floor-standing enclosure
Outdoor Heavy Duty (HD) enclosures made of polyester Outdoor Heavy Duty (HD) enclosures made of coated steel.
insulating material. Suitable to be installed in public areas Suitable to be installed in private areas with harsh
thanks to its features: environments thanks to its capacity to resist:
bb anti-pressure and shock resistant bb corrosion (up to C4H level according ISO 12944:1999)
bb anti-posting bb UV.
bb insulated.
Material HD Polyester reinforced with a double layer of fiberglass HD steel with anti-corrosive coating
Finish - Structured finish, 100 % polyester powder
Colour RAL 7035 grey RAL 7035 grey
Conditions of use Outdoor and/or harsh environments Outdoor and/or harsh environments
Ingress protection rating IP65 IP55 IP66 IP55
Mechanical protection rating IK10 IK10
Standards IEC 61439-5: 2010, IEC 62208: 2011, IEC 61439-1: 2011, IEC 61439-5: 2010, IEC 62208: 2011, IEC 61969-3: 2011,
IEC 61969-3: 2011, IEC 60297-3-100: 2009 IEC 60297-3-100: 2009, ISO 12.944: 1999 (C4H)
Certifications See table page 318 See table page 318
Mounting On wall by means of optional 2 options for installation bb On wall by means of bb Directly on floor by
wall mounting accessory on floor: optional stainless steel means of optional plinth
bb with floor mounting kit wall mounting brackets (see page 313)
NSYMF2PLAZ4 or bb On post by means of
NSYMF2PLAZ6 for optional HD post-mounting
integrated plinth (50 mm) device
bb with additional ZZ plinths
(ventilated or non-ventilated)
available as accessory
(200 mm) (see page 311)
Maximum transportable load 500 kg 200 kg 1000 kg
Other characteristics bb Fire resistant (EN 1794-2:2011) New dedicated ventilation New dedicated ventilation
bb Lifting possible from top with eyebolt accessory solutions to be integrated solutions to be integrated
bb New dedicated ventilation solutions to be integrated in roof, in roof, side or plinth in roof, side or plinth
lateral or plinth. 3 ventilation architectures proposed
(see page 316 et 317)
Options Plain door or ribbed door -
Supply bb Curved canopy bb Curved canopy bb Curved canopy bb Curved canopy
bb Handle with keylock bb Integrated plinth bb 3-mm double-bar lock bb Rear panel
(1242E type) and padlock bb Handle with keylock bb Plastic document pocket bb Handle with keylock
bb Door retainer (1242E type) and padlock (A4 size) (1242E type) and padlock
bb Plastic document pocket bb Aluminium cable gland plate bb Door retainer bb Aluminium cable gland plate
(A4 size) bb Door retainer bb Aluminium cable gland bb Door retainer
bb Plastic document pocket plate bb Plastic document pocket
(A4 size) (A4 size)
307
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Dimensions
New
Enclosure with ventilated canopy
DB300625EN-155
38
38
38
(2) (2)
A–95
(2)
A–95
A–95
A–95
(2)
A–95
(2) (2)
A–95
(2) (2) (2)
(4) (4) (4) (4)
(4) (4)
B–95 B–95 B–95 B–95 C–42 C–42
B–95 B–95 C–42
A–150 (1)
A–150 (1)
A–150 (1)
A–150 (1)
A–150 (1)
A+38
A+38
A–150 (1)
(2) (2) (2) (2)
A+38
(2) (2)
260
260
260
C–8 C–8
C–8
C–140 C–140
C–140
37.5 37.5 75 75
37.5 75
A–255
A–255
A–255
25
25
25
25
25
25
B–150 (1) B–150 (1) B–150 (1) B–150 (1) 28.5 28.5 28.5 28.5
B–150 (1) B–150 (1) 28.5 28.5
C 21 C C 21
21
B–120B–120 B–120B–120
(3) (3)
DB300626-107
M8 M8
37
M8
/ 28(5)
M8
C–125(3)
C–125(3)
(2)
C–140
37
23 / 28(5)
C–125(3)
C–125(3)
(2)
C–140
40
C–140
(2) (2) 40
C–140
(2) (2)
25
25
25
25
B–295B–295
23
308
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Dimensions
New
Enclosure with ventilated canopy and plinth-type
open bottom part
DB300815EN
DB300816EN
C-42
38
(2) (2) (2) (2)
(1)
A-95
A-95
A-95
(1)
A-95
(1) (1) (1)
(4) (4) (4) (4)
B-95 B-95 B-95 B-95 C-170
A–95
A–95
(
A-200
(2) (2)
A–95
A–95
(2)
A–253
(2)
A–253
(4) (4)
(4) (1) (1) (4)
B–95 B–95 C–
B–95 B–95
(1) (1)
A-150
A-150
A-150
A-150
A+55
A–150 (1) 260
C-8
A–150 (1)
A–150 (1)
A–150 (1)
B–215 (2) (2)
B–215 (2) (2)
C
C-140
37.5 37.5 C
75 75
A-255
37.5 75
37.5 75
25
25
25
25
25
55
25
25
B-150 B-150 B-150 B-150 28.5 28.5
21
C
B–150 (1) B–150 (1) 2
B–150 (1) B–150 (1) 28.5
C–160 (3)
C–160 (3)
C–160 (3)
C–160 (3)
M8
37
23/28 (5)
M8
23/28C–68
C–68
M8 40
37
(5)
M8
C–68
C–68
40
B–81 B–81
B–81 B–81
(1) 4 bosses with M8 inserts and studs for direct mounting of mounting plates.
(2) Bosses designed to accommodate M8 inserts, ref. NSYTEX8. They are placed:
– On the back of the enclosure, from the height of 1000 mm. They allow the mounting of partial mounting plates and assorted equipment.
– On the top and bottom parts of the enclosure. They are used for mounting the step slides, an internal door, 19" chassis, etc.
(3) Dimensions for mounting on the floor or on a plinth.
(4) Entry dimensions, door open.
(5) Dimension of 28 mm for enclosures with heights of more than 1000 mm (height after the installation of the plain mounting plates with reinforcement foldings).
(6) With a width of 1250 mm in standard supply, 500-mm door on the left and 750-mm door on the right.
309
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Selection guide and accessories
PB502645-21
PB502649-21
PB502667-14
PB502648-8
PB502690-27
Characteristics Polyester enclosure Eyebolts Wall mounting Floor mounting
Anti-posting Plain door accessory kit
door
Top lifting accessory for Wall mounting support To fix the enclosure on
polyester outdoor for polyester outdoor the floor in a correct
Heavy Duty enclosure. Heavy Duty enclosure. way.
bb Maximum load: No change in ingress bb Certification:
500 kg. protection rate. vv Class II insulation
bb Maximum load: following IEC 61439-1
180 kg. vv IP55 following
IEC 50529
vv Infrastructure
standard following
IEC 61439-5.
Material Galvanised cast steel Steel Steel
Colour - - -
Installation - - On dry concrete
Supply 4 4 1
Height Width Depth No. of References
(mm) (mm) (mm) doors
Wall-mounting enclosure
538 500 320 1 NSYPHDT553 NSYPHDT553P - NSYFMPHD -
788 500 320 1 NSYPHDT753 NSYPHDT753P - NSYFMPHD -
Floor-standing enclosure
843 750 420 1 NSYPHDZT774 NSYPHDZT774P NSYPLHD - NSYMF2PLAZ4
750 620 1 NSYPHDZT776 NSYPHDZT776P NSYPLHD - NSYMF2PLAZ6
1093 500 420 1 NSYPHDZT1054 NSYPHDZT1054P NSYPLHD - NSYMF2PLAZ4
750 420 1 NSYPHDZT1074 NSYPHDZT1074P NSYPLHD - NSYMF2PLAZ4
1343 500 420 1 NSYPHDZT1254 NSYPHDZT1254P NSYPLHD - NSYMF2PLAZ4
750 420 1 NSYPHDZT1274 NSYPHDZT1274P NSYPLHD - NSYMF2PLAZ4
620 1 NSYPHDZT1276 NSYPHDZT1276P NSYPLHD - NSYMF2PLAZ6
1250 420 2 NSYPHDZT12124 NSYPHDZT12124P NSYPLHD - NSYMF2PLAZ4
620 2 NSYPHDZT12126 NSYPHDZT12126P NSYPLHD - NSYMF2PLAZ6
1593 750 420 1 NSYPHDZT1574 NSYPHDZT1574P NSYPLHD - NSYMF2PLAZ4
620 1 NSYPHDZT1576 NSYPHDZT1576P NSYPLHD - NSYMF2PLAZ6
1250 420 2 NSYPHDZT15124 NSYPHDZT15124P NSYPLHD - NSYMF2PLAZ4
620 2 NSYPHDZT15126 NSYPHDZT15126P NSYPLHD - NSYMF2PLAZ6
2093 750 420 2* NSYPHDZT2074 NSYPHDZT2074P NSYPLHD - NSYMF2PLAZ4
PB502691-22
PB502692-31
PB502693-32
* Vertical doors.
310
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Selection guide and accessories
PB502664-25
PB500072-16
PB502673-30
PB502684-21
PB502670-31
Ventilated ZZ plinth 200 mm** Plain mounting plate Roof ventilation Anti-burglary
ZZ plinths 200 mm** module accessory
Height: 200 mm. The front Height: 200 mm. The front The enclosures with Ventilation module to enable Anti-burglary accessory for
parts cannot be removed. parts cannot be removed. height of ≥ 1000 mm have airing from the top of the polyester outdoor Heavy Duty
Includes a polyester It is provided with one or intermediate impressions for enclosure (H = 95 mm) in accordance with
anti-insect filter. two reinforcement cross-rails, installing mounting plates of a with insect protection. ENV 1627-1630:2011 class 2.
adjustable to adapt to the lesser height (M8 inserts, It keeps the Insulation
position of the cables. ref. NSYTEX8, to be ordered Class II according to
separately). IEC 61439-1:2011.
Ultra-reinforced polyester Ultra-reinforced polyester Galvanised sheet-steel Steel with anti-corrosive Steel with anti-corrosive
coating coating
- - - Structured finish, Structured finish,
100 % polyester powder 100 % polyester powder
RAL 7035 grey RAL 7035 grey - RAL 7035 grey RAL 7035 grey
- - bb Direct installation on M8 - Easy installation on the outside
inserts at the rear of the of the enclosure
enclosure or on step slides
for depth adjustment
(see page 202)
bb In the 2-door enclosures, it
is possible to install 1 complete
mounting plate or 2 individual
mounting plates
1 1 1 1 1
- - NSYPMM55 - -
- - NSYPMM75 - -
PB502630bis-24
PB502630-22
PB502694-22
** The coupling kit NSYMUPLA••• is not applicable for enclosures using ZZ or ZH type plinths.
311
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Selection guide and accessories
PB500114-11
PB500527-13
PB500022-31
PB500156-28
PB502653-17
Side panel mounting for SFHD. Horizontal position Rail fixed on the
only. Do not use for inserts in the rear of
dynamic loads. the enclosure with
It brings 10 mm 8-mm screws.
separations between
enclosure and wall.
Material Steel with anti-corrosive coating Stainless-steel AISI Steel
304L
Finish Structured finish, 100 % polyester - Anti-corrosive coating
powder
312
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Selection guide and accessories
PB500072-16
PB500461-13
PB502484-22
PB502486-19
PB502672-13
PB502671-18
PB502670-20
Heavy Duty Stainless-steel plinths 200 mm Plain mounting Roof
padlockable Ventilated plinths Standard plinths plate ventilation
double lock module
For wall-mounting Front and rear kit Lateral kit Front and rear kit Lateral kit
enclosures
Easy mounting The front and rear of They are fixed to the The front and rear of They are fixed to the - Ventilation module
instead of the the plinth consists corner of the plinth the plinth consists corner of the plinth to enable airing
standard lock. of 4 corners with by mounting screws. of 4 corners with by mounting screws. from the top of
2 panels. 2 panels. the enclosure
(H = 95 mm) with
insect protection.
Zamack Stainless-steel AISI Stainless-steel AISI Stainless-steel AISI Stainless-steel AISI Galvanised steel Steel with anti-
304L 304L 304L 304L corrosive coating
Anti-corrosive coating Scotch-Brite brushing
®
- Structured finish,
100 % polyester
powder
- - - - - - RAL 7035 grey
- bb For wall-mounting enclosure: it is necessary to order separately the plinth mounting kit - -
(ref. NSYAPFXWM) composed
by mounting hardware and drilling jig
bb For floor-standing enclosure: mounting in the holes for mounting the enclosures to the
floor
- - - - - - -
Delivered with 3 mm 1 kit 1 kit 1 kit 1 kit 1 mounting plate and 1
double-bar metal key mounting elements
NSYAEDLPADS3DHD - - - - NSYMM32 -
NSYAEDLPADS3DHD - - - - - -
NSYAEDLPADS3DHD - - - - NSYMM54 -
NSYAEDLPADS3DHD - - - - NSYMM64 -
NSYAEDLPADS3DHD NSYSPFVX6200 NSYSPLVX3200 NSYSPFX6200 NSYSPSX3200 NSYMM66 -
NSYAEDLPADS3DHD - - - - NSYMM75 -
NSYAEDLPADS3DHD NSYSPFVX6200 NSYSPLVX3200 NSYSPFX6200 NSYSPSX3200 NSYMM86* -
NSYAEDLPADS3DHD NSYSPFVX8200 NSYSPLVX4200 NSYSPFX8200 NSYSPSX4200 NSYMM88 NSYS3CVR84HD
NSYAEDLPADS3DHD NSYSPFVX6200 NSYSPLVX4200 NSYSPFX6200 NSYSPSX4200 NSYMM106 NSYS3CVR64HD
NSYAEDLPADS3DHD NSYSPFVX8200 NSYSPLVX4200 NSYSPFX8200 NSYSPSX4200 NSYMM108* NSYS3CVR84HD
from the outside with standard tools. For plain and silkscreened mounting plates: In wall-mounting enclosures with
bb Material: stainless-steel. widths of 1000 and 1200 mm, it is possible to install 2 mounting plates at
NSYSKAV References different depths using an additional central step slide NSYSDRSDCR
(more information on page 218).
16 anti-vandalism screws for NSYSKAV
PB502689-29
stainless-steel plinth
Key for anti-vandalism screws NSYKSKAV
NSYKSKAV for stainless-steel plinth
313
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Accessories overview
Installation accessories
Mounting acc. Telequick system 19" accessories
PB500523-30
PB502436-27
PB500504-20
Polyester: Page 238 Polyester: Page 228 Steel: Page 326
Steel: Page 220 Steel: Page 219
314
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Thermal accessories
PB502975-19
PB502683-22
New PB502668-22
PB502676-22
PB502688-21
Characteristics Fanbox Filter Roof filter for IP55 HD Metal Anti-vandalism
fanbox Grille kit for HD metal
grille
bb Free flow rate: 550 m3/h Replacement G3 M1 Roof G2 round synthetic Slim grille (35 mm Mountings that help to
(50/60 Hz). type synthetic filter for filter designed to cover external depth). prevent to open the
bb Minimal depth inside the HD metal grille. the fanbox. Covers Includes a G3 M1 filter. grille from the outside
enclosure (90 mm). bb Dimensions: completely the fanbox with standard tools
bb Allows multiple cooling 223 x 223 mm. and helps to protect it (EN 1627-1630:2011
architectures (see page 316 et from dust and humidity. Class 2).
317). Mandatory for fanbox
installation in the Roof
ventilation module for
IP55 configurations.
Material Plastic - - Steel with anti-corrosive Steel with anti-
coating corrosive coating
Finish - - - Structured finish, 100 % -
polyester powder
Colour RAL 7016 dark grey - - RAL 7035 grey -
Ingress protection - - - IP55 -
rating
Mechanical protection - - - IK10 -
rating
Supply 1 (grille not included) 5 1 1 grille delivered with 1 kit
G3 M1 type synthetic
filter (223 x 223mm)
and mountings
Voltage References Reference Reference Reference Reference
24 V DC NSYCVF550M24FB NSYCAF223T NSYCAF190 NSYCAG223LFHD NSYCAAPVHD
115 V AC NSYCVF550M115FB
230 V AC NSYCVF550M230FB
222.8 90 300 35
DB300827-EN
DB300828
315
222.8
62
Ø 222
315
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Ventilation architectures
New
DB300824
2 2 3
DB300824 1
S-Line T-Line
Architecture benefits bb Most common and competitive architecture bb High capacity of extraction calories up to 1500 W
bb Maximum heat dissipation to extract bb Noise level with 1 fan: 55 dB when installed inside the upper
800 W-1000 W ventilation module
bb ∆T° of 5°C bb ∆T° of 5°C
bb Easy access to mount-dismount fanbox bb Air flow in vertical axis
bb Air flow in horizontal axis
IP55 metal grille Fanbox IP55 metal grille Fanbox Roof ventilation module
(1 filter NSYCAF190
Door Side Door Side Door Side for each Fanbox)
Polyester outdoor HD enclosure
References Amount to be installed Amount to be installed References
NSYPHDT553 - - - - - - - - -
NSYPHDT553P - - - - - - - - -
NSYPHDT753 - - - - - - - - -
NSYPHDT753P 1 to 2 - 1 to 2 - 1 to 2 - - - -
NSYPHDZT774 - 1 to 2 - 1 to 2 - 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT774P 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT776 - 1 to 2 - 1 to 2 - 1 to 2 1 to 2 1 NSYPCVR76HD
NSYPHDZT776P 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 NSYPCVR76HD
NSYPHDZT1054 - 1 - 1 - 1 1 1 NSYPCVR54HD
NSYPHDZT1054P 1 to 2 1 1 to 2 1 1 to 2 1 1 1 NSYPCVR54HD
NSYPHDZT1074 - 1 to 2 - 1 to 2 - 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT1074P 1 to 4 1 to 2 1 to 4 1 to 2 1 to 4 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT12124 - 1 to 3 - 1 to 3 - 1 to 3 1 to 3 1 NSYPCVR124HD
NSYPHDZT12124P 1 to 4 1 to 3 1 to 4 1 to 3 1 to 4 1 to 3 1 to 3 1 NSYPCVR124HD
NSYPHDZT12126 - 1 to 3 - 1 to 3 - 1 to 3 1 to 3 1 NSYPCVR126HD
NSYPHDZT12126P 1 to 4 1 to 3 1 to 4 1 to 3 1 to 4 1 to 3 1 to 3 1 NSYPCVR126HD
NSYPHDZT1254 - 1 - 1 - 1 1 1 NSYPCVR54HD
NSYPHDZT1254P 1 to 3 1 1 to 3 1 1 to 3 1 1 1 NSYPCVR54HD
NSYPHDZT1274 - 1 to 2 - 1 to 2 - 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT1274P 1 to 4 1 to 2 1 to 4 1 to 2 1 to 4 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT1276 - 1 to 2 - 1 to 2 - 1 to 2 1 to 2 1 NSYPCVR76HD
NSYPHDZT1276P 1 to 4 1 to 2 1 to 4 1 to 2 1 to 4 1 to 2 1 to 2 1 NSYPCVR76HD
NSYPHDZT15124 - 1 to 3 - 1 to 3 - 1 to 3 1 to 3 1 NSYPCVR124HD
NSYPHDZT15124P 1 to 4 1 to 3 1 to 4 1 to 3 1 to 4 1 to 3 1 to 3 1 NSYPCVR124HD
NSYPHDZT15126 - 1 to 3 - 1 to 3 - 1 to 3 1 to 3 1 NSYPCVR126HD
NSYPHDZT15126P 1 to 4 1 to 3 1 to 4 1 to 3 1 to 4 1 to 3 1 to 3 1 NSYPCVR126HD
NSYPHDZT1574 - 1 to 2 - 1 to 2 - 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT1574P 1 to 4 1 to 2 1 to 4 1 to 2 1 to 4 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT1576 - 1 to 2 - 1 to 2 - 1 to 2 1 to 2 1 NSYPCVR76HD
NSYPHDZT1576P 1 to 4 1 to 2 1 to 4 1 to 2 1 to 4 1 to 2 1 to 2 1 NSYPCVR76HD
NSYPHDZT2074 - 1 to 2 - 1 to 2 - 1 to 2 1 to 2 1 NSYPCVR74HD
NSYPHDZT2074P 1 to 4 1 to 2 1 to 4 1 to 2 1 to 4 1 to 2 1 to 2 1 NSYPCVR74HD
Steel outdoor HD enclosure
References Amount to be installed Amount to be installed References
NSYS3HD8630 1 to 2 - 1 to 2 - 1 to 2 - - - -
NSYS3HD8840 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 NSYS3CVR84HD
NSYS3HD10640 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 to 2 1 1 NSYS3CVR64HD
NSYS3HD10840 1 to 4 1 to 2 1 to 4 1 to 2 1 to 4 1 to 2 1 to 2 1 NSYS3CVR84HD
NSYSFHD12640 1 to 3 1 to 3 1 to 3 1 to 3 1 to 3 1 to 3 1 1 NSYSFCVR64HD
NSYSFHD12660 1 to 3 1 to 3 1 to 3 1 to 3 1 to 3 1 to 3 1 1 NSYSFCVR66HD
NSYSFHD12840 1 to 4 1 to 3 1 to 4 1 to 3 1 to 4 1 to 3 1 to 2 1 NSYS3CVR84HD
NSYSFHD12860 1 to 4 1 to 3 1 to 4 1 to 3 1 to 4 1 to 3 1 to 2 1 NSYSFECA66HD
NSYSFHD16660 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 1 1 NSYSFCVR66HD
NSYSFHD16840 1 to 4 1 to 4 1 to 4 1 to 3 1 to 4 1 to 3 1 to 2 1 NSYS3CVR84HD
NSYSFHD16860 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 1 to 2 1 NSYSFECA66HD
NSYSFHD20840 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 1 to 4 1 to 2 1 NSYS3CVR84HD
NSYSFHD1212402D 1 to 4 1 to 3 1 to 4 1 to 2 1 to 4 1 to 2 1 to 3 1 NSYSFCVR124HD
NSYSFHD1212602D 1 to 4 1 to 3 1 to 4 1 to 3 1 to 4 1 to 2 1 to 3 1 NSYSFCVR126HD
NSYSFHD1612402D 1 to 4 1 to 4 1 to 4 1 to 3 1 to 4 1 to 3 1 to 3 1 NSYSFCVR124HD
NSYSFHD1612602D 1 to 4 1 to 4 1 to 4 1 to 3 1 to 4 1 to 3 1 to 3 1 NSYSFCVR126HD
316
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD
DB300824 Ventilation architectures
2 2 3
This table helps to configure
thermal architectures, but it is
highly recommended to use
ProClima Software to ensure the
right thermal solution according
to the selected architecture.
5
4
I-Line
bb Integrated architecture particularly suitable for public areas
bb High capacity of extraction calories up to 1500 W
bb Noise level with 1 fan: 55 dB when installed inside the upper ventilation module
bb Good extraction flow rate power
bb Air flow in vertical axis
317
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Certifications
Single door: 1, 2, 3, 3R, 4, 4X, UL 508A Standard for Industrial Control Panels -
5, 12 & 13
Double door: 1, 2, 3, 3R, 5, 12
& 13
STEEL
Spacial SFHD (floor-standing enclosures)
IP55, IK10, lifting: 1000 kg max. IEC 62208: 2011 Empty enclosures for low-voltage switchgear and -
controlgear assemblies - General requirements
Strength of materials and parts IEC 61.439-5: 2010 Low-voltage switchgear and controlgear assemblies -
Part 5: Assemblies for power distribution in public
networks
Corrosion resistance ISO 12.944: 1999 Paints and varnishes-corrosion protection of -
C4H steel structures by protective paint systems
Part 6: laboratory performance testing methods
Climatic test, Biological Test, IEC 61969-3: 2011 Electronic "Mechanical structures for electronic -
Resistance against chemically equipment - Outdoor enclosures"
and mechanical active substances. Part 3: environmental requirements, tests and
Mechanical test, Lifting and safety aspects
stifness test
Space for electronics IEC 60297-3-100: 2009 Mechanical structures for electronic equipment -
Dimensions of mechanical structires of the 482.6 mm
(19 in) series - Part 3-100: basic dimensions of front
panels, subracks, chassis, racks and cabinets
Dimensional EIA-310-E Cabinets, Racks, Panels, and associated equipment -
Single door: Type 1, 3R, 12, 12K UL 508 A: 2007 Standard for Industrial Control Panels -
Double door: Type 1, 3R, 12, 12K
Spacial S3HD (wall-mounting enclosures)
IP66, IK10, lifting: 200 kg max. IEC 62208: 2011 Empty enclosures for low-voltage switchgear and
controlgear assemblies - General requirements
Strength of materials and parts IEC 61.439-5: 2010 Low-voltage switchgear and controlgear assemblies -
Part 5: Assemblies for power distribution in public
networks
Corrosion resistance ISO 12.944: 1999 Paints and varnishes-corrosion protection of
C4H steel structures by protective paint systems
Part 6: laboratory performance testing methods
Climatic test, Biological Test, IEC 61969-3: 2011 Electronic "Mechanical structures for electronic
Resistance against chemically equipment - Outdoor enclosures"
and mechanical active substances. Part 3: environmental requirements, tests and
Mechanical test, Lifting and safety aspects
stifness test
Space for electronics IEC 60297-3-100: 2009 Mechanical structures for electronic equipment -
Dimensions of mechanical structires of the 482,6 mm
(19 in) series - Part 3-100: basic dimensions of front
panels, subracks, chassis, racks and cabinets
Dimensional EIA-310-E Cabinets, Racks, Panels, and associated equipment -
Single door: Type 1, 2, 3, 3R, 4, UL 508A Standard for Industrial Control Panels -
4X. 5, 12 & 13
318
Thalassa PHD Outdoor Heavy Duty enclosures
Spacial S3HD - SFHD Certifications
Corrosion resistance C4H ISO 12.944: 1999 Paints and varnishes-corrosion protection of steel -
structures by protective paint systems - part 6:
laboratory performance testing methods
Anti-vandalism kit for HD metal grille (NSYCAAPVHD)
Resistance Class 2 ENV 1627:2011 Burglar resistance - Requirements and classification -
Upper ventilation module (PHD / SFHD / S3HD)
IP55 (in conditions of use) IEC 60529: 2013 Degrees of protection provided by enclosures (IP Code) -
Corrosion resistance at level C4H ISO 12.944: 1999 Paints and varnishes-corrosion protection of -
steel structures by protective paint systems
Part 6: laboratory performance testing methods
HD POLYESTER ENCLOSURES
Anti-burglary accessory (NSYBGN•••HD)
Resistance Class 2 ENV 1627:2011 Burglar resistance - Requirements and classification -
Corrosion resistance at level C4H ISO 12.944: 1999 Paints and varnishes-corrosion protection of -
steel structures by protective paint systems
Part 6: laboratory performance testing methods
ZZ plinths (NSYZZ••• & NSYZZ•••VHD)
ZZ Plinth: IP44 (in conditions IEC 60.529:2013 Degrees of protection provided by enclosures (IP Code) -
of use)
Ventilated ZZ Plinth: IP43
(in conditions of use)
Eyebolts (NSYPLHD)
Maximum load 500Kg IEC 62208: 2011 Empty enclosures for low-voltage switchgear and -
controlgear assemblies - General requirements
HD STEEL ENCLOSURES
Stainless steel plinths (NSYSPFVX••• / NSYSPLVX••• / NSYSPSX••• / NSYSPSX•••)
Ventilated plinth: IP20 IEC 60.529:2013 Degrees of protection provided by enclosures (IP Code) -
(in conditions of use)
Standard plinth: IP30
(in conditions of use)
319
Spacial SF & S3D Seismic and nuclear enclosures
Introduction
PB501884-SE
zone 4 (4 m/s²)
zone 3 (3 m/s²)
zone 2 (2 m/s²)
320
Spacial SF & S3D Seismic and nuclear enclosures
Introduction
Floor acceleration:
Acceleration of a particular floor in a building (at the location of an equipment item)
resulting from a given earthquake.
Note: In practice, floor acceleration can be broken down into horizontal and vertical components.
Test results
Spacial SF and S3D offer Earthquake characteristics Floor acceleration (m/s²) (2)
Standard 5G (5) 6G (5) IEC 60068-3-3 (Table 3) Required response spectra (RRS) Test response
Seismic Intensity scales Ground IEC 60068-3-3 EDF spectra (TRS)
zones acceleration ag
S3D SF, SF SF 5G, S3D 6G UBC (3) Richter MSK (4) m/s² Horiz. Vertic. Horiz. Vertic. Specification Horiz. Vertic.
19", SFP SFP 5G
0 < 5.5 < VIII N/A
1-2 2 6 3 - -
3 ≥ 5.5 VIII to IX 3 9 4.5 6 4.8 HN 20-E-53 9 9
(6) and ≤ 7
4 > 7 > IX 5 15 7.5 10 8 CRT 91-C-112-00 15 12
(1) (1) (1) 20 24 M12D0168610 29.6 40
(1) The IEC 60068-3-3, 1991-02 standard has not yet been updated since the events at FUKUSHIMA.
(2) Floor acceleration = ag x K x D (§8.2.7), where:
K = amplification factor = 3 (Table 4 of IEC 60068-3-3)
D = direction factor = 1 for the horizontal direction, = 0.5 for the vertical direction (Table 5 of IEC 60068-3-3).
(3) Approximate Uniform Building Code values for the zone.
(4) MSK (Medvedev-Sponheuer-Kamik, corresponding to the modified Mercalli intensity scale).
(5) The 5G and 6G designations refer to the amplified maximum acceleration value read respectively on the horizontal RRS of the EDF standard CRT91C11200 and on
vertical RRS of the EDF MRI standard for large equipment.
(6) Except larger enclosures. Consult us.
Comment: g = acceleration due to gravity rounded off to the nearest whole number (1g = 10 m/s²).
g g g g g g
5 5 5 7 7 7 10 10 10
1 1 1 1 1 1
1 1 1
0.1 0.10.1
0.1 0.10.1
0.05 0.05
0.05 0.03 0.03
0.03 0.3 0.30.3
1 1 1 10 10 10 100 200 Hz 100100200200
HzHz0.2 0.2
1 0.2 1 1 10 10 10 100 200 Hz 100100
200200
HzHz 1 1 1 10 10 10 100 200 Hz100100200200
HzHz
SF 5G SFSF
5G5G SF 3G SFSF
3G3G S3D 6G S3D 6G6G
S3D
Amplified maximum acceleration: acceleration expected at the center of gravity of the equipment
321
Spacial SF & S3D Seismic and nuclear enclosures
Introduction
New SF
Spacial SF 5G cubicles Reinforced crosspieces
PB502602-70
bb Two reinforced crosspieces ensure the structure's
(for control and automation) mechanical strength.
and Spacial SFP 5G cubicles
(for LV power distribution)
have been designed to withstand
earthquakes up to UBC zone 4.
PB502633-32
Panel mounting
bb Mounting systems prevent loosening of the screws.
PB502602-47
PB502934-21
Reinforced plinths
PB502636-40
322
Spacial SF & S3D Seismic and nuclear enclosures
Characteristics
PB502602-25
Characteristics Nominal Load tested Plain door Plain door 100 mm plinth Mounting 19" rack*
dimensions (mm) (kg) plate*
Two configurations were tested:
bb Control and automation configuration. 250 kg load uniformly distributed over the plain mounting plate at the rear.
bb Configuration with fixed 19" rack. 250 kg load distributed in accordance with a standard (FPR).
H W D Without rack
Spacial SF 5G
A&C configuration 2000 800 600 250 NSYSF5G20860 NSY5G2SP206 NSYS5GPC86 NSYMP208 -
19" configuration 2000 600 800 250 NSYSF5G20680 NSY5G2SP208 NSYS5GPC86 - NSYRCK42
* For plain mounting plate and 19" rack, see information on cubicle reinforcement.
NB: The customer must ensure good cubicle/base connection.
PB502637-25
PB502638-25
PB502639-30
PB502640-23
PB502638-25
323
Spacial SF & S3D Seismic and nuclear enclosures
Characteristics
324
Spacial SF & S3D Seismic and nuclear enclosures
Characteristics
PB502641-23
Characteristics Nominal Additional load Plain door Side panels 100 mm plinth
dimensions (mm) tested (kg)
Two configurations of the Spacial SFP 5G cubicle were tested. Functional systems were installed on the cubicle and
inspected at the end of the test to check that there was no damage. The two test configurations were as follows:
bb 1600 A configuration;
bb 3200 A configuration.
H W D
Spacial SFP 5G
1600 A configuration Spacial SFP 2000 700 500 350 NSYSFP5G20750 NSY5G2SP205 NSYS5GPC75
Busbar duct 2000 300 500 350 NSYSF5G20350 NSY5G2SP205 NSYS5GPC35
3200 A configuration Spacial SFP 2000 700 800 450 NSYSFP5G20780 NSY5G2SP208 NSYS5GPC78
Busbar duct 2000 300 800 450 NSYSF5G20380 NSY5G2SP208 NSYS5GPC38
NB: - The width (300 mm) of the Spacial SFP 5G cubicle for the busbar duct is not compatible with the Spacial SF 5G cubicle.
- The customer must ensure good cubicle/base connection.
325
Spacial SF & S3D Seismic and nuclear enclosures
Accessories
or uprights
Mounting plate Limited with SF/SFP 5G Not compatible at the back of NSYMP●●●
PB500477-6
the enclosure
plate
plates
326
Spacial SF & S3D Seismic and nuclear enclosures
Introduction
New S3D
Spacial S3D 6G cubicles are Strength
PB502761SE-152
bb Panel thickness:
designed to withstand earthquakes vv Casing + door: 20/10 mm;
up to UBC zone 4. vv Entry flange: 15/10 mm.
PB502933-56
PB502934-21
bb EDF 1600 security locking system with captive key.
Wall mounting
PB502761SE-56
327
Spacial SF & S3D Seismic and nuclear enclosures
Characteristics, accessories
PB502765
328
Spacial SF & S3D Seismic and nuclear enclosures
Characteristics
329
Spacial SF & S3D Seismic and nuclear enclosures
Accessories
customization department
to be provided for
customization department
to be provided for
customization department
to be provided for
customization department
to be provided for
330
Spacial S3D Seismic and nuclear enclosures
Introduction
Strength
PB502761SE-152
New bb Panel thickness:
vv Casing + door: 20/10 mm;
vv Entry flange: 15/10 mm.
The Spacial S3D 6G K3 cubicle
meets K3 requirements in
accordance with RCCE 2012.
Decontaminatable smooth paint,
PB502773-32
PB502761SE-56
Earth continuity
PB502770-36
Wall mounting
PB502761SE-56
331
Spacial S3D Seismic and nuclear enclosures
Characteristics, accessories
PB502765
332
Spacial S3D Seismic and nuclear enclosures
Accessories
customization department
to be provided for
customization department
to be provided for
customization department
to be provided for
customization department
to be provided for
333
Spacial S3D Seismic and nuclear enclosures
Customization
Width
2 Cut-outs
We meet the K3 requirements as per RCCE 2012 for the cut-outs mentioned below.
These cut-outs appear in the Reference File.
80
DB300854
30
30
30
30
140 80
47
60
Entry flange
20
DB300853
20
30
30
20
30 30 30 30
20
Top view
A
Depth A
20
150 65
200 82
250 98
300 115 15 15
400 148 20
334
Spacial S3D Seismic and nuclear enclosures
Customization
New 3 Paints
Referencing of the following paints in the FNP (national paint file):
4 Packaging
We can produce a special corrosion protection packaging (Gardac type).
PB502823-50
335
Spacial S3D Seismic and nuclear enclosures
A demanding nuclear market
336
Spacial S3D Seismic and nuclear enclosures
A demanding nuclear market
several equipment
Their certification depends on their location. K3 K1 K1
Equipment interfacing between the core and the other
K3
buildings is always K1 (risk of radioactive leakage). K1 K2K3 K1K3 K1
K3 K3 K1 K2 K3
K3
337
Spacial EMC solution Electromagnetic protected steel
enclosures
Introduction
General
The increasing presence of electromagnetic interference in industrial environments,
together with the use of equipment susceptible to such interference requires the use
of suitably protected enclosures.
In order to suppress electromagnetic interference, S3HF enclosures, due to the type
of sheet metal and special gaskets used, fulfil two functions:
bb Provision of adequate screening, with the effectiveness of a Faraday cage.
bb Ability to provide effective protection of sensitive equipment by using galvanised
sheet metal chassis, and by following recommended installation procedures.
Electromagnetic interference
Electromagnetic disruptions comprises an electrical field E generated by a differing
potentials, and a magnetic field M, caused by current circulation, which combine
to form electromagnetic field.
The electromagnetic interference or "noise" is a disruptive electrical signal which
affects the useful signal and it likely to cause a malfunction.
Interference can be carried through the conductors or emitted through the
environment.
The waves of electrical or magnetic fields are reflected when they meet the sheet
metal of the enclosure.
The effective rate of the screening or dampening "a" of the incident wave is
Incident measured in decibels (dB) using the following formulae:
wave
E0
a = 20 log (dB) for electrical fields,
E1
Reflected Radiated
wave wave H0
a = 20 log (dB) for magnetic fields,
H1
bb E0 and E1 are the current values of the electrical field, before entering and after
entering the enclosure respectively.
Enclosure surface bb H0 and H1 are the magnetic field values.
Outside Inside
338
Spacial EMC solution Electromagnetic protected
steel enclosures
Introduction
Installation
According to the type of interference generated by the devices:
bb Low frequencies, "conducted interference" (up to 30 MHz),
bb High frequencies, "radiated interference" (higher than 1 MHz),
the rules to be taken into account relate to the choice of components that provide
the most economical solution to complete the installation.
Low-frequency interference
bb Importance of the protection systems:
vv filters, overvoltage suppressor, isolating transformer for the power supply,
vv cable length.
High-frequency interference
bb Importance of the installation method:
vv earth connections, cable length and section,
vv cable selection and rules, cable runs, connections,
vv enclosures and installation.
Specifics
Screen connections
DB300007SE-40
Earth plate or 5m
0 -1 It is recommended to earth screens at both ends. In addition, it is advisable to
reference potential
L ≤1
sheet connected to increase the number of intermediate earth connections.
the chassis If the screen is only earthed at one end, there can be a considerable difference in
potential between the two ends. In addition, this screen will be ineffective against
external high-frequency interference.
Transformers
DB300008SE-39
Poor
The transformer chassis must be mounted, metal to metal, on the reference potential
plate, that is, on a plain chassis supporting the equipment.
Excellent
Soldered
Earth connection Metal ground plate or
by the screws reference potential sheet
Cable runs
DB300010SE-60
Paint = INSULATION The metal ducts and conduits, when correctly connected, provide an extremely
effective second screen for the cables.
Cable ends must be screwed to the metal enclosures in order to provide an effective
connection.
Excellent
The interfering and sensitive components, cables etc. should be installed in separate
enclosures or located at some distance from each other.
Note: For further information, consult your local sales office or our educational leaflet entitled
"Electromagnetic compatibility".
339
Spacial EMC solution Electromagnetic protected
steel enclosures
Introduction
EMC floor-standing
enclosure, IP55.
See page 396 for details or consult our web site www.schneider-electric.com
340
Spacial EMC solution Electromagnetic protected
steel enclosures
Introduction
The next illustrations indicates the attenuation (dB) curves related to the frequency
DB300006
(MHz).
PB500415
Reflected Radiated
wave wave
Attenuation (dB)
Enclosure surface
Outside Inside
Magnetic field
The presence of 55 % aluminium on the
Electrical field
surface of the sheet metal ensures good
reflection of electromagnetic waves.
Frequency (MHz)
70
60
50
Attenuation (dB)
40
30
20
Mean vertical attenuation values
Mean horizontal attenuation values
10
0
10 100 1000
Frequency (MHz)
70
60
Attenuation (dB)
50
40
30
20
Mean vertical attenuation values
10 Mean horizontal attenuation values
0
10 100 1000
Frequency (MHz)
341
Spacial S3HF - SMHF - SFHF Electromagnetic protected steel
enclosures
Characteristics
PB500205-38
342
Spacial S3HF - SMHF - SFHF Electromagnetic protected
steel enclosures
Characteristics
PB501683-34
PB501685-28
Spacial SMHF Spacial SFHF
bb Body bb Structure
vv body made from Aluzinc steel painted on the outside only. vv galvanised-steel structure,
bb Door vv top and bottom frame, vertical upright.
vv front plain door (with reinforcement frame) made from Aluzinc steel, bb Claddings
vv special gasket (IP + EMC) between body and door. vv enclosure with screwed panels (on side and rear) and front plain door
bb 1 plain door with door-reinforcement frame. (with reinforcement frame) made from Aluzinc steel,
bb Left or right opening to 120°. vv side panels have to be ordered separately,
bb Standard handle with 5-mm double bar. vv special gasket (IP + EMC) between body, door and panels.
bb 1 part cable-gland plate with special gasket (IP + EMC). bb 1 single plain door with door-reinforcement frame (double door on request,
please consult us).
bb Left or right opening to 120°.
bb Delivered with standard locking system handle and 5-mm double-bar insert.
bb 1 rear panel screwed from the outside.
bb 1 removable roof.
bb 1 part cable-gland plate with special gasket (IP + EMC).
Painted on the outside with epoxy-polyester resin (inside not painted) Painted on the outside with epoxy-polyester resin (inside not painted)
RAL 7035 grey RAL 7035 grey
IP55 IP55
IK10 IK10
RoHS compliant RoHS compliant
- -
References Side panel references Enclosure references
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
- - -
NSYSMHF18660P NSY2SPHF186 NSYSFHF18660
- NSY2SPHF184 NSYSFHF18840
NSYSMHF18860P NSY2SPHF186 NSYSFHF18860
- NSY2SPHF204 NSYSFHF20640
- NSY2SPHF206 NSYSFHF20660
- NSY2SPHF208 NSYSFHF20680
- NSY2SPHF2010 NSYSFHF206100
NSYSMHF20840P NSY2SPHF204 NSYSFHF20840
NSYSMHF20860P NSY2SPHF206 NSYSFHF20860
- NSY2SPHF208 NSYSFHF20880
- NSY2SPHF2010 NSYSFHF208100
- NSY2SPHF226 NSYSFHF22660
- NSY2SPHF226 NSYSFHF22860
- NSY2SPHF228 NSYSFHF22880
343
Spacial S3HF - SMHF - SFHF Electromagnetic protected
steel enclosures
Dimensions
Spacial S3HF
A: Height. Fig. 1
B: Width.
C: Depth. B C B
DB300148-170
21
40
40
125
A-44
10
A-50
A-75
A- 5
A
A-44
B-44
25*
125
B-50
B-75
B-50
B-75
B- 5
B-95/135*
B- 5
Fig. 2
B C B
DB300148-170
C
21 21
40
40
125
A-44
10 10
A-50
A-75
A- 5
A-44
B-44
A
A- 5
A-50
A-75
25*
B-44
125
B-50
B-75
B-50
B-75
B- 5
B-95/135*
B- 5
344
Spacial S3HF - SMHF - SFHF Electromagnetic protected
steel enclosures
Dimensions
Spacial SMHF
A: Height. B
DB300717-143
C
B: Width.
17
B-150
C: Depth.
A-150
A-150
A-150
A-62
A-90
A
C+5
17
B-280
C-130
600/800
345
Spacial S3HF - SMHF - SFHF Electromagnetic protected
steel enclosures
Dimensions
Spacial SFHF
A: Height.
DB300389EN-151
B: Width.
C: Depth.
Ø 5.2
Ø 10.5
A - 150
A+ 9
A - 150
A
18 x 18
min. 85
max. C - 90
27
C - 90
C+5
B - 150 C + 42
B - 125
B - 219
C - 125
C - 90
B - 90
Ø 16
B
346
Spacial S3HF - SMHF - SFHF Electromagnetic protected
steel enclosures
Accessories
Earth braids
PB500084-43
347
ATEX enclosures Enclosures for explosive
atmospheres
Introduction
What is ATEX?
bb It is a term commonly used to describe potentially EXplosive ATmospheres
and standards for protection systems and equipment.
bb Two European directives, ATEX 99/92/CE and ATEX 94/9/CE, and international
Heat standards IEC 60079 and IEC 61241, harmonized with EN European standards,
O apply to this field.
xy el
ge Fu
n
ow is a potentially explosive atmosphere defined
H
Chain
reaction e re according to ATEX?
ph
os bb An potentially explosive atmosphere is defined as a mix of flammable substances
atm
ve in the form of gas, vapour, dust (cloud or deposit) which, in air and under normal
o si atmospheric conditions, can completely or partially catch fire in the form of an
pl
Ex explosion when exposed to a source of ignition.
Zone 2 Zone 1
bb They are classified into groups and zones according to directive 99/92/CE
Zone 0 and IEC standards as follows:
Zone 21
Zone 22
Equipment for potentially
explosive atmospheres
bb Since 1st July 2003, European directive ATEX 94/9/CE has made it compulsory
to use certified electric or non-electric equipment when it must be installed in zones
with explosive atmospheres (gas or dust).
bb Certification must be provided by a body which is notified according to the same
directive.
bb The body notifies its assessment of the quality of the production and certifies that
the product complies with the health and safety demands defined in the directive
and the international standards.
bb The certificate shows the category of the product by marking, and thus the zone
and atmosphere in which it can be used.
bb The standards define the following types of protection for electric equipment:
348
ATEX enclosures Enclosures for explosive
atmospheres
Introduction
PB500062
The final solution
must be certified
by a notified body
ATEX components
349
ATEX enclosures Enclosures for explosive
atmospheres
Introduction
environments
Thalassa PLMEX polyester enclosure
bb The Thalassa PLMEX polyester enclosure is certified by the LOM with
no. LOM 10ATEX3051U (component certification).
bb Seven sizes: from 307 x 255 x 164 mm to 1056 x 852 x 350 mm.
bb Degree of protection: IP66.
bb Ambient temperature limits: -20°C ≤ Ta ≤ +60°C.
bb Resistance to external mechanical impacts: IK10.
bb Black colour.
350
ATEX enclosures Enclosures for explosive
atmospheres
Introduction
Personnel safety
PB500411-32
Blind nut for external earth connection.
PB500407-32
Robust
PB502996-32
nuts.
Label
DB300871
Réf: NSYS3DEX
0942
12345678
LCIE 02 ATEX 0037 U Made in France
0081 II 2 GD EX e IIC Gb Ex tb IIIC Db
DB300073-27
Delivered in
reusable cardboard
with assembly
instructions
enclosed.
351
Spacial S3DEX - S3XEX Enclosures for explosive
Thalassa PLMEX
atmospheres
Characteristics, accessories
PB500075-23
PB500096-14
PB500148-26
PB500072-12
PB500100-12
352
Spacial S3DEX - S3XEX Enclosures for explosive
Thalassa PLMEX
atmospheres
Characteristics, accessories
PB500148-26
Accessories for Thalassa PLM enclosures can be installed in Thalassa PLMEX enclosures.
However, plastic accessories should not be used, due to the risk of a static charge.
PB501332-25
PB500150-40
PB500101-18
PB500102-16
PB500104-16
PB500022-20
PB500136-19
NSYAEFPFSC /
NSYAEFPFXSC NSYPFXPLM
353
Spacial S3DEX - S3XEX Enclosures for explosive
Thalassa PLMEX
atmospheres
Dimensions
Spacial S3DEX
1-door enclosure
A: Height 30 (1) 23 (2)
DB300143-29
DB300147-62
B: Width
C: Depth (2)
105
(1) 4 M8 x 25 mm backstuds.
(2) 2 M6 x 17.5 mm earthing studs.
A-75 (3)
A-45 (4)
(3) Stud centre-to-centre distance. Detail (1) Detail (2)
A
(4) Crimped blind nut centre-to-centre distance. Ø 12
DB300144-29
(5) Blind nut for external earth. M6
1
(4)
(2)
16
B-75 (3) (1) C-23
Detail (4) B-45 (4) C
4 crimped blind nuts for direct
fixing of mounting brackets
DB300145-23
B
16
M8
1
C-48
C-15
C-28
Ø 12 (2)
(5) (2)
Detail (5)
1 crimped blind nut for
35
the external earth B-42
(8)
Spacial S3XEX
Fig. 1
DB300583
B C
DB300582-55
21 25
40
45
A-44
10
A-75
A-50
A-5
A
B-44
Detail A Detail D
M6
16.5
16.5
1.5
1.5
B-50 Detail A
B-75 M6
Detail B Detail C
Detail C
B-5
354
Spacial S3DEX - S3XEX Enclosures for explosive
Thalassa PLMEX
atmospheres
Dimensions
Spacial S3XEX
Fig. 2 Fig. 3
B C B
DB300584EN-65
DB300585-29
21
40 40
114
114
10
A-75
A-44
A-50
A-44
25
A-5
25*
A
A
B-44
B-44
External dimensions (mm)
114
114
Height (A) Width (B) Depth (C) Fig.
300 200 150 1 B-50
B-50 800 Detail B Detail D
400 300 200 1 B-75 B-75
500 400 200 2**
600 400 200 2
700 500 250 2
800 600 250 2 B-76.4* B-76.4* B-136
1000 800 300 3 B-5 B-5 B-5
Thalassa PLMEX
175
NSYPLMEX3025 104
DB300846EN
131.5
220
103
14
168.5
214
308
275
225
286
255
25
40
53 20
5 160
NSYPLMEX43/54/64/75/86/108
I
DB300847
N
Ø8 M8
O
E H
J
F
16
G
M
A
L
L
D
B 5 C
355
Spacial HMI enclosures Human-Machine Interface
PB501199-29
PB501195-23
PB500501-34
PB501200-33
356
Spacial HMI enclosures Human-Machine Interface
The Spacial S3CM offer for human-machine interface combines robustness with
aesthetics and ergonomics. Consist of:
bb control enclosure,
bb a keyboard-box,
bb a suspension system of arms and joints, for a fixed or rotating solutions,
bb and support accessories.
> See page 358
PB500068-61
The Spacial SDX range of control desks offers all the functions required to set up a
control station that meets the industrial or infrastructural needs of applications in
harsh environments or in the food and beverage sector.
Easy to implement, compatible with dialogue components, guaranteeing the security
and protection of control devices, these control desks, with their range of
dimensions, meet the strictest needs of their users.
> See page 369
357
Spacial S3CM Human-Machine Interface
Introduction
PB500433-33
bb 2 tube sizes in extruded steel, 50 and 80 mm square,
- a box-keyboard thickness 40/10e mm.
- a system of arms and joints bb Top wall reinforced by a plate with a thickness of
30/10e mm.
fixed or rotating
- accessories.
The global dialogue system
combines robustness with aesthetics
and ergonomics. Aesthetics
PB500418-29
Ergonomics
PB500446-37
Easy
PB500439-21
Flexibility
PB500300
See page 396 for details or consult our web site www.schneider-electric.com
358
Spacial S3CM Human-Machine Interface
Introduction
Y
DB300149-89
kg
DB300153-86
L
150
80
Heavy loads
50
100
a
L
b
50
Medium loads
L
a X
1000 2000 3000
b l (mm)
Y
DB300150-88
DB300153-86
kg
L
a 150
80
b
Heavy loads
50
100
50
b Medium loads
X
1000 2000 3000
l (mm)
* The load (a + b + enclosure + installed equipment) must be less than the maximum load.
Example
kg Y
DB300151-65
150
1 - Total load (kg) = 80 kg. 80
2 - Length (L) = 1200 mm. Heavy loads
3 - Suspension system
without intermediate joint. 50
100
80
Recommended system
> Medium loads U 50.
50
Medium loads
X
1000 1200 2000 3000
l (mm)
359
Spacial S3CM Human-Machine Interface
Characteristics
PB500431-32
PB500435-66
Perforated rails installed
on lateral studs.
PB500432-49
360
Spacial S3CM Human-Machine Interface
Dimensions
F F J J
D
A
D
A
G
B + 97 A: Height
B: Width
C C C: Depth
B B
W600 enclosure + box-keyboard installation Figure 1 Figure 2
Enclosure depth from 200 to 250 Enclosure depth 300
B
L LK K
K
DB300156-50
DB300157-38
DB300158-50
K
Ø7 (1)58 (1) Ø9 87
K
H
K
H
87
58
(1)
H
Ø 54 Ø 87
H
H
B + 97
361
Spacial S3CM Human-Machine Interface
Specific accessories
PB500438-35
DB300160-21
PB500437-42
120˚
212212
250250
562 116
699
562 116
699
600
600
125125
Support
PB500439-26
PB500440-16
PB500442-31
PB500441-30
Characteristics Support
Vertical Laptop computer Keyboard
Installation on the left or right rail of the frame of the control enclosure.
Material Sheet steel
Finish Structured finish, epoxy-polyester powder
Colour RAL 7035 grey
Thickness 12/10e mm 20/10e mm 20/10e mm
Weight 1.15 2.04 2.16
References
Height Width Depth
(mm) (mm) (mm)
315 230 - NSYCMSPP - -
- 350 310 - NSYCMBPC -
- 500 200 - - NSYCMBPT
DB300161-23
DB300163-37
DB300162-50
200
315
310
500 37
230 350 37
362
Spacial S3CM Human-Machine Interface
Specific accessories
Suspension system
Tube
Fixing on support
Fixing on enclosure
Inter-tube fitting
Tube
PB500422
50 /80 4
L
50/80
363
Spacial S3CM Human-Machine Interface
Accessories
Suspension system
1 2 3 4
PB500424-40
PB500425-46
PB500426-46
PB500423-46
DB300166-65
DB300168-60
B C
12 x M12 DIN916
DB300167-55
D B
ØC
D
A
L
H
J
I
G
ØC
l
8 x M12
E
C
L DIN916 F J
I
C
B C ØK
l
8 x M12
L DIN916
B
D
A
H L
E
H
J
I
G
F
G
E
H IF J E
I
ØE
A
b
E
ØE
G
H
K
J
A
b
ØD
ØF
L
ØD
ØF
Reference
NSYCMUCPAD87
364
Spacial S3CM Human-Machine Interface
Accessories
Suspension system
5 6 7 8
PB500427
PB500428-42
PB500429
PB500430-48
300˚ 300˚
DB300171-55
DB300169-33
DB300173-40
0º
B C
0-3
DIN916
2 x M12
I
ØE
F
A
F
E
G
ØD
B
D
D
C
A
B
A G
12 x M12 C H
DIN916 F
DIN916
4 x M12
A M6 E21
0º
ØM
0-3
60
92
I
M
60
bb Material: aluminium.
H
75
bb Finish: structured finish, powder.
B
D
bb Colour: RAL 7040 grey. F
I A G
Weight 0.025 kg 0.08 kg C H
UA 50 mm square 80 mm square M6 21
References
66
60
92
NSYCMACS50 NSYCMACS80
M23 x 2
DB300172EN-58
14 SW24 60
75
M20 x 1.5
365
Spacial S3CM Human-Machine Interface
Selection guide
Enclosure References
H x W x D (mm) Tube section
top wall U 50 mm U 80 mm
300 x 300 x 200 NSYS3CM303020 -
PB500421-24
300 x 400 x 200 NSYS3CM304020 -
400 x 400 x 200 NSYS3CM404020 -
400 x 600 x 250 NSYS3CM406025* -
500 x 500 x 250 NSYS3CM505025 -
600 x 600 x 200 NSYS3CM606020* -
600 x 800 x 300 - NSYS3CM608030
800 x 600 x 300 - NSYS3CM806030*
Tube References
Length (m) Tube section
U 50 mm U 80 mm
0.5 NSYCMT5005 NSYCMT8005
PB500422-33
1 NSYCMT5010 NSYCMT8010
1.5 NSYCMT5015 NSYCMT8015
2 NSYCMT5020 NSYCMT8020
1 Fixed base
joint
NSYCMUMC50 NSYCMUMC80
PB500425-30
3 Rotating straight
fitting
4 Horizontal
inter-tube joint
NSYCMUTC50 NSYCMUTC80
PB500427-24
5 Fixed bracket
6 Rotating mounting
on enclosure
NSYCMUCC50 NSYCMUCC80
PB500429-28
7 Rotating mounting
in bracket on
enclosure
enclosure
366
Spacial S3CM Human-Machine Interface
Examples
DB300154
2 See page 364 1 See page 364
5 1
Inter-tube fitting Inter-tube fitting
5 See page 365 -
6
E
A
DB300154
D Mounting on enclosure
7 See page 365
6 Mounting on enclosure
6 See page 365
DB300154
C 1
367
Spacial SD - SDX Human-Machine Interface
Introduction
PB501202-16
There are two versions of the Compact control desk:
The range of Spacial SD control bb Front accessibility: designed for straightforward
solutions.
desks provides all the functions bb Front and rear accessibility through a removable
required of a workstation intended panel: enables the installation of two adjoining plates
and to work at the rear.
for industrial and infrastructure The control desk with console offers full accessibility,
applications. since it is fully accessible from the rear thanks to the
3-point closure door it includes.
For Spacial SD, the accessibility which allows quick
and easy work is one of its main priorities.
PB501202-46
Easy
PB501197-32
Convenience
PB501199-14
Compatibility
PB501194-19
See page 396 for details or consult our web site www.schneider-electric.com
368
Spacial SD - SDX Human-Machine Interface
Introduction
PB502438-5
The high quality of the standard finish enables very
The association of a monobloc easy maintenance while avoiding contamination.
The hygienic feet made from 316L stainless-steel,
control desk with one or more adjustable between 140 mm and 200 mm height,
consoles enables all combinations. make it easier to clean under the enclosures.
Complete accessibility to the
inside of the control desk thanks
Resistance to corrosion
PB501232-32
to its design without intermediate High resistance to corrosion. 304L and 316L stainless-
crossbars. steels provide the best solutions for applications
in extremely demanding environments.
PB501224-56
bb Stainless-steel accessories:
vv plinths, locks.
bb Accessories of the steel control desks offer:
vv mounting plate, pneumatic opening stay, etc.
Convenient
PB501269
Examples of associations
Consoles and control desks
DB300593
See page 396 for details or consult our web site www.schneider-electric.com
369
Spacial SD - SDX Human-Machine Interface
Characteristics
SD SD
PB501208-37
PB501200-39
370
Spacial SD - SDX Human-Machine Interface
Characteristics
SD SDX
PB501202-36
PB501267-41
Compact control desk with rear panel
Sheet steel Stainless-steel sheet
Removable rear panel. It enables the installation of two racks back-to-back, allowing the installation of a large number of devices, while ensuring full
accessibility from the front and the rear.
At the top, these control desks are equipped with cable-entry cut-outs, that allows the installation of one or more modular consoles.
Easy removable and reversible door, opening to 120°. Locking by 3-mm doublebar lock (other inserts or cylinders also available, to be ordered separately,
see page 380).
Desk lid equipped with a pneumatic opening stay. Opens to 75°. Perforated reinforcement rails with a pitch of 25 mm.
Top cable-entry cut-outs covered by a entire blanking cover.
Control desk equipped with adjustment rails with a pitch of 25 mm and brackets allowing adjustment of the mounting plate depth.
Cable-gland plate with 2 adjustable parts, with polyurethane gasket.
M8 x 18-mm earthing screw for equipotential connection between the door and the body.
371
Spacial SD - SDX Human-Machine Interface
Dimensions
DB300556EN-102
B-121 (1) B-121 (1) 444
(
B-150 B-150 365 1)
75°
466
127
73
1024
1024
899
722
764
650
764
650
750
379
60 70
B B-61/2 31
24
B 396
93.5 93.5
Common side view.
(1) Useful clearance.
25
25
469
469
B-187 B-187
B-57 B-57
Ø 14 1 Ø 14
62.5
62.5
1
47.5
47.5
240
240
Cable-gland plate clearance dimensions (mm)
M8 x 18 M8 x 18
Width Maximum opening B-125 B-125
B-280 56 B-50 B-50
566
127
73
1028
832 (1)
1028
764
899
650
764
650
722
750
60 70
b
24.5
B B-61/2 a
B 496 31
200
93.5 165 93.5 200 165
165
150
25
25
94.5
79.5
600
600
1 1
78.5
340
340
372
Spacial SD - SDX Human-Machine Interface
Dimensions
DB300595EN-38
DB300596EN-35
DB300597EN-32
100
562
126
195
70
60 70
831
900
a b
723
1025
1025
750
650
650
764
764
B–150 B–150
31
24.5
B B–61/2 B–61/2 527
200 B
Common side view.
165 150 200 165
(1) Useful clearance.
94.5
79
25
25
Width Maximum opening
597
597
93.5 165 93.5
B-280 370 B–187 B–187
Detail of the
B–57 B–57
95.5
95.5
cable-entry
Adjustment of the depth openings.
Ø12 Ø12
of the mounting plate (mm)
78.5
78.5
336
336
Depth Min. Max.
a 45 395 M8x18 M8x18
B–164 B–164
b 126 476 B–50 B–50
536
478 (1)
25
25
400
4
400
421 4 79
(1)
1310 (1)
2
1372
117
650
650
4
477 (1)
70
Cable-gland plate clearance dimensions (mm) 88
B-280 56
23.5
Notes Ø 14 Ø 14
92.5
92.5
DB300599-51
435 25
350 (1)
435
387
435
387
387
325
325
325
53
483
53 53
483
35
477
536
1508
107
1508
B B 107
262 262 206
B
361
(1) Useful clearance.
(2) Same dimensions for the rear panel.
373
Spacial SD - SDX Human-Machine Interface
Specific accessories overview
Composition accessories
PB501814-77
PB501206-30
PB500330-33
PB501213-35
Page 376 Page 378 Page 379
PB500995-28
Installation accessories
Mounting acc.
PB501207-33
Page 382
374
Spacial SD - SDX Human-Machine Interface
Common accessories overview
Cable management
PB502439-55
PB500966-40
PB500958-22
Page 270 Page 289
Thermal management
Heaters Ventilation
PB502050-29
PB501044-26
Others
Earthing
PB500948-98 PB500217-18 PB500084-24
Page 302
375
Spacial SD - SDX Human-Machine Interface
Accessories
Modular consoles
PB501226-46
SD SDX
PB501206-25
SD SDX
PB500102-23
PB501203-21
PB502560-21
F
F
376
Spacial SD - SDX Human-Machine Interface
Accessories
Modular consoles
800
NSYSD8R NSYSDX8 NSYSDC42 / NSYSDCX42 / 2 x NSYRP2 2 x NSYRPX2
NSYSDC43 NSYSDCX43
1000
NSYSD10R NSYSDX10 NSYSDC42 / NSYSDCX42 / 3 x NSYRP2 3 x NSYRPX2
NSYSDC43 NSYSDCX43
377
Spacial SD - SDX Human-Machine Interface
Accessories
SD SDX Floor
For more information, see page 100.
PB502591-18
PB502580-17
PB502589-30
PB502578-30
NSYSD8 NSYSPF8100 NSYSPF8200 NSYSPFX8100H NSYSPFX8200H NSYSPS4100SD NSYSPS4200SD NSYSPSX5100H 2 x NSYSPSX5100H
NSYSD10 NSYSPF10100 NSYSPF10200 NSYSPFX10100H NSYSPFX10200H NSYSPS4100SD NSYSPS4200SD NSYSPSX5100H 2 x NSYSPSX5100H
NSYSD12 NSYSPF12100 NSYSPF12200 NSYSPFX12100H NSYSPFX12200H NSYSPS4100SD NSYSPS4200SD NSYSPSX5100H 2 x NSYSPSX5100H
NSYSD8R NSYSPF8100 NSYSPF8200 NSYSPFX8100H NSYSPFX8200H NSYSPS5100SD NSYSPS5200SD NSYSPSX5100H 2 x NSYSPSX5100H
NSYSD10R NSYSPF10100 NSYSPF10200 NSYSPFX10100H NSYSPFX10200H NSYSPS5100SD NSYSPS5200SD NSYSPSX5100H 2 x NSYSPSX5100H
NSYSD12R NSYSPF12100 NSYSPF12200 NSYSPFX12100H NSYSPFX12200H NSYSPS5100SD NSYSPS5200SD NSYSPSX5100H 2 x NSYSPSX5100H
378
Spacial SD - SDX Human-Machine Interface
Accessories
Door
Pneumatic opening stay
PB501213-42
Document lip
PB501214
bb Retaining bar to be fixed on the front of the inclined control desk lid. Prevents
documents and equipment from falling.
bb Material: PVC, RAL 7011 grey.
bb Mounting: mounting by adhesive.
379
Spacial SD - SDX Human-Machine Interface
Accessories
Locking system
The Control desks are supplied with 3 mm double-bar
PB501215-72
escutcheon locks as standard.
PB501216-18
DB300833
380
Spacial SD - SDX Human-Machine Interface
Accessories
Locking system
PB501217-38
Pivoting handle
To be installed on the rear door of Control desk with console, replacing the flat escutcheon supplied as standard.
Ergonomic locking system with pivoting handle (delivered without insert).
Broad range of inserts for covering the greatest variety of needs (shape inserts, DIN cylinders, KABA, ASSA).
Changing the opening direction to right / left thanks to the symmetric design of the lock unit (no linkages to be removed).
Lock unit supported by 2 screws.
PA 6 charged with 30 % fibreglass
RAL 7011 grey
IK10
650°C
-
-
-
-
NSYSDH
Accessories
Shape inserts References Cylindrical barrels References
PB500616-18
PB500614-19
381
Spacial SD - SDX Human-Machine Interface
Accessories
Mounting accessories
PB501219-37
DB300742
type
B
DB300740
A C
DB300744
type
D E
(1) For this installation, order a set of 4 adjustment rails and mounting brackets (see page 383).
(2) For this installation, order a set of 2 uprights ref. NSYTVR14 and set of 4 adjustment rails and 4 mounting brackets.
382
Spacial SD - SDX Human-Machine Interface
Accessories
Mounting accessories
PB500483-24
PB501210-32
PB501808-35
PB501815-24
Characteristics Mounting brackets Adjustment rails and Technical uprights PC screen support
mounting brackets
Set of 4 mounting brackets. Set of 4 rails and 4 mounting Set of 2 equipment uprights. For a control desk with
Depth adjustment on brackets. Support for mounting Telequick monobloc console with a depth
25 mm pitch. To install a plain mounting plate mounting plates and rails. of 600 mm.
Included as standard with desk or a Telequick mounting plate, This support is a galvanised
(all versions). either at the top or across the mounting plate, in horizontal
To be ordered separately when height of the monobloc control position, fixed to the adjustment
required for installation of two desk with console. rails of the console.
back to back mounting plates in For positioning 2 plates (back
control desks with rear access. to back), order mounting
brackets ref. NSYMPBSD.
Material Galvanised steel - Zinc-coated -
Thickness 40/10e mm - 20/10e mm -
Maximum load 250 kg - - 50 kg/m2
Supply - - - Delivered with mountings
References
For desk width (mm)
600 NSYMPBSD - - -
800 NSYMPBSD - - NSYPCS8
1000 NSYMPBSD - - NSYPCS10
1200 NSYMPBSD - - NSYPCS12
1600 NSYMPBSD - - NSYPCS16
For control desks
with console
Depth (mm)
400 - NSYMPB4SD - -
600 - NSYMPB6SD - -
For control Centre-
desk height to-centre
(mm) distance
(mm)
1000 650 - - NSYTVR8 -
1400 1250 - - NSYTVR14 -
383
Spacial SF Human-Machine Interface
Introduction
PB500664-28
bb Anti-glare glazed door designed for viewing until
in an industrial environments. 25,5" screens.
bb Cable entry made easier by a cable-land plate
in 2 pieces.
PB500501-54
Ergonomics
PB500665-28
bb Access to the various functions and working heights,
guaranteeing optimum comfort.
bb Partial doors delimit the access to each function
with a 3 mm double-bar lock.
bb Built-in screen and CPU support.
bb Built-in keyboard and mouse support.
Robust
PB500490-35
Simple
PB500495-21
Locking system
PB500667-35
See page 396 for details or consult our web site www.schneider-electric.com
384
Spacial SF Human-Machine Interface
Characteristics
PB500208-27
Characteristics Spacial SF PC rack
bb Partial door for PC screen, with Securit® anti-glare glass.
bb Plain partial door for CPU (enclosures with height
of 1800 mm).
bb Hinged plain door for keyboard.
bb Plain partial door for optional installation of A4 printer
support.
bb Partial front doors opening to the right.
bb Plain rear door, reversible opening direction (right or left).
bb Roof and side panels fixed from the inside.
bb Cable-gland plate with 1 entry.
Finish Structured finish, epoxy-polyester powder paint
Colour RAL 7035 grey
Ingress protection rating IP55, or IP40 with hinged keyboard
Mechanical protection rating IK10
Certifications UL*, CUL
Height Width Depth No. of compartments References
(mm) (mm) (mm)
1600 600 600 3 NSYSF16660PC
800 3 NSYSF16680PC
1800 600 600 4 NSYSF18660PC
800 4 NSYSF18680PC
450
DB300242EN-60
450
25
.5
430
609
” 430
609
200 200
1802.5
1602.5
200
1500
1300
900
759
759
600 600
PC rack with a height PC rack with a height
of 1800 mm. of 1600 mm.
*1, 12, 12 K.
385
Spacial SF Human-Machine Interface
Accessories
Plinth
PB502581-18
PB502580-17
PB502579-30
PB502578-30
Material Folded sheet steel, corner with a thickness of 25/10e mm Folded sheet steel
Finish Painted with epoxy-polyester resin Painted with epoxy-polyester resin
Colour RAL 7022 grey RAL 7022 grey
Ingress protection rating IP30 IP30
Mechanical protection rating IK10 IK10
Installation - -
Supply bb Height 100 mm: 4 corners, 2 panels (front and rear), bb Height 100 mm: 2 side panels, 4 corner covers and mounting
4 corner covers and mounting elements elements
bb Height 200 mm: 4 corners, 4 panels (2 front and 2 rear), bb Height 200 mm: 4 side panels (height of 100 mm, 2 for each
4 corner covers and mounting elements side), 4 corner covers and mounting elements
References
Width Depth 100 mm 200 mm 100 mm 200 mm
(mm) (mm)
Locking system
PB500646-43
PB500666-37
Detail of 3 mm DB lock
on partial door.
386
Spacial SF Human-Machine Interface
Accessories
Trays
PB500523-24
PB500668-24
PB500669-23
PB500670-24
Fixed Trays Telescopic Trays
bb Optional installation of a supplement fixed or telescopic tray directly on structure or on cross rails.
bb Acceptable load: 150 kg for fixed trays and 50 kg for telescopic rails, both evenly distributed.
bb See more details and other options on Mounting: trays, page 237.
- -
- -
- -
- -
- -
On structure On cross rails On structure On cross rails
- - - -
Tray Tray Universal Quick Tray Telescopic Tray Telescopic Universal Quick
cross rail cross rail rails rails cross rail cross rail
40 mm (1 row) 40 mm (1 row) 40 mm (1 row) 40 mm (1 row)
NSYFXT6060 NSYFXT6060 NSYSUCR4060 NSYSQCR4060 NSYFXT6060 NSYTTG60 NSYFXT6060 NSYTTG60 NSYSUCR4060 NSYSQCR4060
- NSYFXT6060 NSYSUCR4080 NSYSQCR4080 - - NSYFXT6060 NSYTTG60 NSYSUCR4080 NSYSQCR4080
Other accessories
PB500672-33
387
Spacial SMX Human-Machine Interface
Introduction
PB501223-69
equipment installed in corrosive bb Anti-glare glazed door designed for viewing 14" and
17" screens by removing part of the silkscreen printing.
or specially environments that bb Cable entry made easier by a cable-gland plate
require washing or exposure (at the rear) in 2 pieces.
to sprays of liquid.
PB501223-108
Sealing
PB501223
Optional accessories
PB501223
Ergonomic
PB501266-32
Hygiene
PB501223-107
Resistance to corrosion
PB501233-32
See page 396 for details or consult our web site www.schneider-electric.com
388
Spacial SMX Human-Machine Interface
Characteristics, accessories
PB501228-57
PB502485-21
PB502483-26
PB502486-23
PB502484-32
Characteristics 304L stainless-steel PC racks Front plinth Plinth side panels
Composition The front and rear of the plinth They are fixed to the corner
bb Top and bottom partial doors on the front side. consists of 4 corners with 2 or of the plinth by 2 mounting screws.
bb Pivoting panel for the keyboard. 4 panels.
bb Plain rear door.
Monitor-screen compartment
bb The anti-glare glazed door is designed for viewing
screens:
vv 14" as standard,
vv 17" by removing a part of the silkscreen printing.
bb The height of the monitor support can be adjusted.
bb The monitor shelf can withstand a maximum weight
of 50 kg.
CPU / keyboard compartment
bb The keyboard fixed to the inside becomes
operational by tilting the central panel.
bb The CPU is placed on a height-adjustable shelf,
visible and accessible through a pivoting, transparent
shutter.
Optional accessories
bb Hygienic feet H 200 mm: NSYPHX200.
bb Shelf installed on a sliding rail, with adjustable height.
bb Telescopic tray: NSYTTG60.
Material Monobloc structure in 304L stainless-steel sheet, 316L stainless-steel 316L stainless-steel
micro-beaded finish.
Can be made in 316L stainless-steel on request
Ingress protection rating IP55, even with the keyboard drawer open IP30 IP30
Mechanical protection rating IK10 IK10 IK10
Supply - bb Height 100 mm: 4 corners, bb Height 100 mm: 2 side panels,
2 panels (front and rear), 4 corner 4 corner covers & mount elements
covers and mounting elements bb Height 200 mm: 4 side panels
bb Height 200 mm: 4 corners, (height of 100 mm, 2 for each
4 panels (2 front and 2 rear), side), 4 corner covers and
4 corner covers & mount elements mounting elements
Height Width Depth References
(mm) (A) (mm) (B) (mm) (C) 100 mm 200 mm 100 mm 200 mm
1600 600 600 NSYSMX16660PC NSYSPFX6100H NSYSPFX6200H NSYSPSX6100H 2 x NSYSPSX6100H
1800 600 600 NSYSMX18660PC NSYSPFX6100H NSYSPFX6200H NSYSPSX6100H 2 x NSYSPSX6100H
600
DB300592SE-38
380 600
14’’
595
17’’
305
(1)
(2)
310
(1)
1280
105
A D
D
1600 690
1800 890
100
389
Spacial S3D, SF and SM Variable speed drive
flush-mounting kits
Introduction
Tightness
PB502941-71
New IP55 to IEC 60529 with polyurethane seal provided.
PB502942-39
They are mounted in the Spacial range Set of slide-rails allowing the variable speed drive
of steel enclosures (floor-standing and to be mounted quickly and efficiently.
PB502939-12
PB502938-27
390
Spacial S3D, SF and SM Variable speed drive
flush-mounting kits
Characteristics
New
PB502936-32
PB502935-25
391
Spacial S3D, SF and SM Variable speed drive
flush-mounting kits
Dimensions
New
NSYPTDS1 NSYPTDS2
235 22 265 22
DB300874
DB300875
L R L
R
360
420
NSYPTDS3
295 22
DB300876
L R
555
NSYPTDS4 NSYPTDS5
385 435 206
DB300877
DB300878
150.5
800
975
392
Spacial S3D, SF and SM Variable speed drive
flush-mounting kits
Mounting accessory
PB502945-57
New
DB300880
DB300879
393
Spacial SF Automobile application
Introduction
PB500745-32
The built-in secure interlocking system for the door
enclosure is interlocked by the (on demand) of the "incoming"/"outgoing" enclosures
control of the main switch or circuit allows Spacial SF enclosures to be adapted to the
requirements of the American car industry.
breaker. A built-in interlocking system
with runner rods prevents the
opening of the "outgoing" enclosure
doors. Access is only allowed when
the main switch or circuit breaker
is in "O" position and the main door
is open. Manual activation of the
rods unlocks the other doors and
allows access.
Designed to be associated with
certain circuit breakers or switches:
– Square D (9422 A1).
– Schneider Electric.
The system is limited for
configurations up to 4 columns.
NSYSLCKP
PB500743-67
NSYSLCKS NSYSODS
394
Spacial SF Automobile application
Characteristics
PB500747-35
PB500744-31
PB500746-43
Characteristics Interlocking Activation Interlocking
for main door for secondary doors for secondary doors
bb System for unlocking the main door System installed in the main enclosure. System for interlocking the outgoing
adapted to the switches: Activated by manual operation, enclosures connected to one another
vv Allen Bradley (1494 VH11). preventing the opening of the secondary by runner rods that lock their doors.
vv Square D (9422 A1). enclosures connected to one another
vv Siemens (FH0H). by runner rods.
vv Schneider Electric. It has a secure function which consists
bb Unlocks the main door when the switch of a part that forces the system into the
is in the open position "O". position in which the secondary
bb The main door interlocking system enclosures are locked in order to lock
requires the ordering of both references: the main door.
vv 1 Activation for secondary doors.
vv 2 Interlocking for secondary doors.
Material Steel bb Mechanism: zinc-coated steel Steel
bb Activation handle: black plastic
Finish Zinc-coated - Zinc-coated
Mounting - - Mounting to the structure of the
enclosures by screws
Supply 2 brackets for mounting the configured Elements for activating the main door Elements for interlocking the secondary
panel, interlocking elements, switch and and mountings. doors and mountings.
mountings. Configured panel and handle For the complete function, both activation For the complete function, both activation
not included. 1 and interlocking systems 2 need 1 and interlocking systems 2 need
to be ordered. to be ordered.
References Width (mm) References
NSYSLCKP NSYSODS 600 NSYSLCKS6
800 NSYSLCKS8
1000 NSYSLCKS10
PB500745-22
395
The customised solutions
Configured offer
Introduction
Standard
enclosure
PB502737-71
Configured Standard
accessories
Services
Configured
solution
●●Change the cladding composition ●●Make square and circle cut-outs before painting
(panels, doors…) the enclosure (body, cable gland plate, sides)
●●Merge and assemble several enclosures and mounting plates
(only for Spacial SF and Thalassa PLA)
Ensures safety and the best protection against rust
E
nclosure composition stick 100 % The enclosure is ready to be equipped
to customer needs
No need to have qualified personnel to merge
enclosures
Mounting of standard
Painting
accessories
●●Change the colour of the complete enclosure ●●Pre-installation of accessories inside or out-side
(choice of 36 colours) of the enclosure (ex.: mounting plate, plinth,
●●Modify the coating of the raw material canopy, etc.)
(ex.: zinc, etc.)
Enclosure ready to be equipped
I ndustrial painting ensures the best protection
T
otally customized
396
The customised solutions
Configured offer
●●One configurator for 14 countries ●●Users can indicate machining requests directly
& all configurable offers on our DXF drawing
●●Compatibility between enclosure ●●Decreasing price (depends on quantity)
& accessories ●●Manufacturing time adapted to each offer
●●Availability of both on-line & off-line versions ●●All data are provided to registered users
●●Illustrated products help you in your choice (quotation, technical datasheet, etc.)
●●FAQ information for faster understanding ●●Reusable smart code
4 - Select services
●●Mounting
●●Machining
●●Painting
●●Assembly
2 - Select enclosure
●●Select product range
●●Select material
●●Select enclosure type
DB300836-15
397
The customised solutions
Specific offer
Introduction
42-22779605-83
PB502734-111
Specific
20
experts
specialized on
different materials
and different
products
PB502736-48
398
The customised solutions
Specific offer
Step 1
Environment in which you’ll install the enclosure(s)
> Airborne debris; temperature variations; UV rays?
> Indoor or outdoor use?
> In wash down environment?
> In high traffic environment?
Step 2
Application(s) needs of your enclosure(s)
> Access control; building automation; motor & motion control?
> Need to protect against electromagnetic disturbances?
> Use in potentially explosive atmospheres?
Step 3
Enclosure(s) description
> Type of enclosure’s installation?
> Total weight of equipments in the enclosure?
> Design: color / coating / finish / dimension?
> Body components’ adaptations: cable entry / mounting plate?
> Thermal management adaptations?
> Other accessories adaptations?
> Additional information: labeling / packaging / logistic?
Step 4
Business profile
> Total quantity of enclosures needed and quantity per batch?
> Frequency of your order: single order / repeat order?
> Delivery time and method demand?
> Stock needs?
> Other comments?
399
Thermal
management
system
400
Universal Enclosures Thermal management system
Contents
ClimaSys 402
Overview 402
ClimaSys CV 406
PB500069
Ventilation systems
PB502596-11
PB502593-11
New 424
ClimaSys CE
Exchangers
PB502631-7
435
PB502615-9
New
ClimaSys CU
Cooling Units
PB502042-6
ClimaSys CR 454
Resistance Heaters
PB502624-10
New 459
ClimaSys CC
Thermal Control
Software 469
401
ClimaSys Thermal management system
Overview
Technological evolution
The miniaturisation of components, the generalisation of electronics and the
appearance of new electronically powered products have made temperature
management into a growing need which must necessarily be considered when
designing electrical and/or industrial control panels.
Cooling Heating
PB501026-12
PB501021-35
systems
PB501029-8
PB502042-4
PB502596-11
Air-air exchangers
Controlling
PB502618-9
hermal control
T
PB501030-28
accessories
PB502593-11
Air-water exchangers
PB502606-16
Thermal software
PB502631-7
PB502615-9
Cooling units
PB500011-33
402
ClimaSys Thermal management system
Overview
Example
Batteries – Accumulators
Manufacturers recommend installing batteries in environments where the controlled
temperature is 15°C... 25°C.
Cold slows down the battery charging and discharging cycles. Heat increases the
evaporation of water in the electrolyte and speeds up the oxidation of the plates.
Using batteries at temperatures above the recommended value therefore reduces
their service life.
PB501017-68
Example
Electronic equipment
Most electronic industrial control systems are equipped with axial fans for their own
thermal control. A failure of the fan can lead to a production halt.
Reduced service life of the fan is one consequence of the enclosure heating up.
24 V DC axial fan.
bb Temperature range: -20... +70°C.
PB501018-81
Example
Variable speed drives
A variable speed drive controlling a 45 kW (60 HP) motor is programmed to work at
temperatures ranging up to 50°C or 60°C.
The power dissipated by this variable speed drive inside the enclosure can reach 1360 W.
This contribution of heat inside the enclosure will cause the top temperature to rise
to 60°C and probably cause a halt in production.
Our solution
Our new thermal offer includes a large range of solutions, suitable for all situations,
from installing a ventilation system to exchangers or even a cooling unit.
Do not hesitate to contact us to find out the best thermal solution for your installation.
403
ClimaSys Thermal management system
Overview
DB300447-18
DB300449-60
DB300448
System Airing Ventilating Air-air exchanger
Natural convection causes the temperature Fans with filters are designed to evacuate Air-air exchangers are equipped with
to drop inside the enclosure. Simple a large amount of heat economically. an aluminium exchange cassette which
solutions for this case include installing separates the internal and external air
grilles (without filter) or lifting the top. circuits and prevents the entry of dust.
When should it be used? This solution can only be used when the When larger amounts of heat need to be The air-air exchangers are used in highly
power to be dissipated is low, in an evacuated in a polluted environment. polluted environments or when it is
environment with small amounts of dust. necessary to evacuate large amounts of
heat while guaranteeing the independence
of the internal and external air circuits.
It is important to have a difference of
temperature of at least 10°C.
DB300453-32
DB300453-32
Td: Desired temperature
DB300454-7
DB300455-7
No No Yes
Advantages bb Economic solution. bb Economic solution. bb The internal and external air circuits
bb No maintenance. bb Easy maintenance. are independent.
bb Quick and easy installation. bb Quick and easy installation. bb Easy maintenance.
bb Even temperature inside the enclosure. bb High protection rating: IP55.
bb High protection rating: IP54 or IP55.
Disadvantages bb Small amount of heat evacuated. bb The temperature inside the enclosure bb The temperature inside the enclosure
bb Reduction of the IP protection rating. is always higher than the external is always higher than the external
bb Risk of entry of dust particles. temperature. temperature.
bb The internal and external air circuits
are in contact.
bb Maintenance required:
filter replacement.
Solutions
PB501021-53
PB501020-28
PB502596-11
PB502618-9
404
ClimaSys Thermal management system
Overview
DB300450-24
DB300452-60
DB300451-67
Air-water exchanger Cooling Heating
Air-water exchangers reduce the temperature Air-conditioning device providing efficient cooling The resistance heaters prevent the formation
inside the enclosure by means of a water-cooled of the enclosure, regardless of the outside air, of condensation and guarantee the ideal temperature
exchange cassette. and prevention against hot spots. for the correct operation of the electronic components.
Temperature control inside the enclosure is
performed by a thermostat which opens and
closes an electro-valve.
The air-water exchangers are used to evacuate The cooling units can be used in the harshest The resistance heaters are used to reheat the industrial
large amounts of heat. They require a cold-water environments, where the temperature can control panel when the ambient temperature is too low
circuit with stable temperature and flow rate. reach up to 55°C. or to prevent the formation of condensation.
They are specially recommended in difficult, These devices control the temperature inside
highly polluted environments where there is the enclosure and include an alarm function
no external air circuit. for signalling operational anomalies.
DB300453-32
DB300453-32
DB300453-32
DB300455-7
DB300456-7
Yes Yes
bb The temperature inside the enclosure does bb Even temperature inside the enclosure. bb Small dimensions.
not depend on the external temperature. bb H igh protection rating: IP55 or IP54 according bb Available in 3 versions:
bb The internal and external air circuits are to model. vv insulated with low surface temperature,
independent. bb Use of an environmentally friendly gas. vv in aluminium when the surface temperature is limited
bb Security device against possible leaks. to 75°C,
bb High protection rating: IP55 or IP54 according vv ultra thin heaters.
to model. bb The fan-equipped resistances guarantee an even
temperature inside the enclosure.
PB502615-12
PB501025-33
PB501027-17
PB501026-17
PB502042-6
PB502606-16
405
ClimaSys CV Thermal management system
Introduction
PB501039-22
PB501040-42
maintenance to secure all Quick installation
the applications. bb Safe, reliable mounting with the assisted mounting
device and system of multi-thickness mounting-clips.
bb Mounting also possible using screws.
bb Easy to invert.
bb To operate as extractors, all the motors can be
DB300448-41
Easy maintenance
PB501041-27
Ventilation offer
DB123816-26
average increase of 50 %
bb Maximum use of surface.
bb Minimum loss of pressure.
406
ClimaSys CV Thermal management system
Introduction
0.8 mm
2
bb For easy and reliable mounting of the ventilation system.
bb With a thickness of 0.8 to 4.5 mm, with no fixings.
3
3 - Inclined profile of the grille
bb To protect the filter against vertical spraying:
vv each slat is protected by the slat above it,
vv the external dimensions remain small.
4.5 mm
4 - IP54-55
PB501036-52
6 The system for holding the synthetic filter in the cavity of the filter holder
guarantees a protection rating of IP54, in the most difficult conditions.
407
ClimaSys CV Thermal management system
Characteristics
Ventilation Systems
Forced ventilation
Characteristics
Material
Colour
Conditions of use
408
ClimaSys CV Thermal management system
PB501050-44 Characteristics
PB501051-36
PB501052-19
PB501052-19
PB501053-21
Forced ventilation fan Forced ventilation fan Forced ventilation fan Forced ventilation fan Forced ventilation fan
38 m3/h 85 m3/h 165 m3/h 300 m3/h 560-850 m3/h
The fans comprise an axial motor, a protective housing on the front and rear surfaces and a filter designed to retain dust particles.
This filter can be replaced during operation without risk of contact with the rotating element.
Injected thermoplastic (ASA PC). self-extinguishing according to UL 94 V-0
RAL 7035 as standard, with the option of RAL 7032
bb The outside temperature (Te) must be 5°C lower than the desired temperature (Ts) inside the enclosure
bb The filters that equip the fans must be cleaned and replaced regularly
bb The surrounding environment must be relatively clean and overfrequent filter replacement should be avoided
bb Bear in mind the pressure losses caused by the outlet element (grille with filter, ventilation louvre or simple opening) when determining the fan flow rate
bb Storage Temperature: -40…+ 70°C
IP54
The cut-out template supplied with the device avoids the need for marking and protects the surface of the enclosure during handling
The device can be equipped with a filter that provides even more efficient protection for your sensitive facilities against dust particles
References
NSYCVF38M230PF* - - - -
NSYCVF38M115PF* - - - -
NSYCVF38M24DPF - - - -
NSYCVF38M48DPF - - - -
- NSYCVF85M230PF - - -
- NSYCVF85M115PF - - -
- NSYCVF85M24DPF - - -
- NSYCVF85M48DPF - - -
- - NSYCVF165M230PF - -
- - NSYCVF165M115PF - -
- - NSYCVF165M24DPF - -
- - NSYCVF165M48DPF - -
- - - NSYCVF300M230PF -
- - - NSYCVF300M115PF -
- - - NSYCVF300M24DPF -
- - - NSYCVF300M48DPF -
- - - - NSYCVF560M230PF
- - - - NSYCVF560M115PF
- - - - NSYCVF850M230PF
- - - - NSYCVF850M115PF
- - - - NSYCVF850M400PF
* Warning: the fan NSYCVF38M230PF & NSYCVF38M115PF MUST NOT be connected to a power conversion module, an inverter or UPS type of power supply!
409
ClimaSys CV Thermal management system
Dimensions
Fan 38 m3/h
Flow curves Dimensions
NSYCVF38M230PF *
DB300458
∆Pa
13
DB300459EN
DB300460
Difference of static pressure (Pa)
20
DB300461-SE
15
137
60 Hz NSYCAG92LPF
91.85
80
10
92 x 92
50 Hz
5
117
49 9
0 10 20 30 40
Flow m3/h
* Warning: the fan NSYCVF38M230PF MUST NOT be
connected to a power conversion module, an inverter or
UPS type of power supply!
Fan 85 m3/h
Flow curves Dimensions
NSYCVF85M230PF
DB300462
∆Pa
60 15
DB300463EN
DB300464
Difference of static pressure (Pa)
DB300465
50
40
60 Hz
124.85
170
30
119
NSYCAG125LPF
20
50 Hz 125 x 125
10
150
62 9
0 20 40 60 80 100
Flow m3/h
∆Pa NSYCVF165M230PF
60
Difference of static pressure (Pa)
DB300467EN
18
DB300469
DB300468
50
40
60 Hz
30
268
222.7
119
20
50 Hz NSYCAG223LPF 223 x 223
10
248
0 40 80 120 160 200 104 9.5
Flow m3/h
410
ClimaSys CV Thermal management system
Dimensions
∆Pa
180 18
DB300471EN
Difference of static pressure (Pa)
DB300473-SE
DB300472
150
120
60 Hz
268
222.7
90
172
60
NSYCAG291LPF
50 Hz
30 223 x 223
248
116 9.5
0 60 120 180 240 300 360
Flow m3/h
∆Pa NSYCVF560M230PF
150
Difference of static pressure (Pa)
125
100
60 Hz
75
50 Hz
NSYCAG291PF
50
25
18
DB300475EN
150
DB300474
DB300476-SE
120
60 Hz
90
NSYCAG291PF
336
290.7
50 Hz
A
60
30 291 x 291
316
0 150 300 400 600 750 900 B 9.5
Flow m3/h
411
ClimaSys CV Thermal management system
Accessories
Ventilation Systems
PB501055-41
PB501054-40
RAL 7035 RAL 7032
Delivered with G2 M1 synthetic standard filter. External part of the grille (for fan or outlet grille)
for changing the colour to RAL 7032.
Material Injected thermoplastic (ASA PC), Injected thermoplastic (ASA PC),
self-extinguishing according to UL 94 self-extinguishing according to UL 94
Colour RAL 7035 RAL 7032
Ingress protection rating IP54 IP54
Height Width Depth Cut-out References
(mm) (mm) (mm) (mm)
137 117 13 92 x 92 NSYCAG92LPF NSYCAG92LPC
170 150 15 125 x 125 NSYCAG125LPF NSYCAG125LPC
268 248 18 223 x 223 NSYCAG223LPF NSYCAG223LPC
336 316 18 291 x 291 NSYCAG291LPF NSYCAG291LPC
PB501057-28
DB300387-26
412
ClimaSys CV Thermal management system
PB501046-62 Accessories
Filters
G2 M1 synthetic standard filters Filters for greasy environments G2 M1 G3 M1 synthetic fine filters Stainless-steel anti-insect filters
For fans and grilles.
-
-
Pack. References Pack. References Pack. References Pack. References
5 NSYCAF92 - - - - 1 NSYCAF92M
5 NSYCAF125 5 NSYCAF125O 5 NSYCAF125T 1 NSYCAF125M
5 NSYCAF223 5 NSYCAF223O 5 NSYCAF223T 1 NSYCAF223M
5 NSYCAF291 5 NSYCAF291O 5 NSYCAF291T 1 NSYCAF291M
PB501056-29
DB300385-23
HD Ventilation Systems
PB502683-22
PB502668-22
PB502675-22
PB502676-22
PB502688-21
413
ClimaSys CV Thermal management system
Accessories
Characteristics PB501058-46
EMC IP54 fan
To effectively protect the equipment against electromagnetic disruptions, the EMC fan is
equipped with:
vv a steel frame covering the plastic elements (self-extinguishing ABS according to standard
UL 94 Fire resistance V0),
vv a metal grille attached to the frame,
vv a beryllium gasket guaranteeing conductivity between the perimeter of the fan unit and the
enclosure.
Ingress protection rating IP54
External Cut-out Flow rate Voltage (V) References
dimensions (mm) (mm) (m3/h)
150 x 150 x 36 125 x 125 56 230 NSY17990
250 x 250 x 36 223 x 223 130 230 NSY17991
325 x 325 x 36 291 x 291 460 230 NSY17992
150 31
DB300479-29
250 36 325 36
DB300481-29
DB300483-29
Ø 202
289
119
127
This solution guarantees protection against electromagnetic disruptions and guarantees IP55.
The EMC cover is installed on the fans or standard IP54 outlet grilles.
The cover, made from painted sheet-steel for outdoor, completely covers the fan or outlet grille.
Conductivity is obtained by means of:
vv a conductive coating (2 Ω),
vv a conductive copper braid.
Colour RAL 7035 grey
Ingress protection rating IP55
Mechanical protection rating IK10
Certifications Absorption curve according to standard IEEE 299 1997 (UNE 50147-1)
Flow rate (m3/h)* with cover Dimensions (mm) References
Free With 1 External Cut-out Sheet-steel painted for outdoor applications
outlet grille RAL 7035
74 53 240 x 180 x 60 125 x 125 NSYCAP125LE
110 82 350 x 305 x 80 223 x 223 NSYCAP223LE
165 123 350 x 305 x 80 223 x 223 NSYCAP223LE
316 265 430 x 373 x 105 291 x 291 NSYCAP291LE
502 430 430 x 373 x 105 291 x 291 NSYCAP291LE
* The impact on the flow rates of the fans with different voltages is similar to the impact of the 230 V fans.
414
ClimaSys CV Thermal management system
PB501059-46 Accessories
IP54
NSY17996
NSY17997
NSY17998
31 36 36
DB300484-5
DB300480-5
DB300482-6
4 6 6
G
B
Minor RAL 7035 RAL 7035
pack. 5 p
C
NSYCAF125L55 NSYCVF85M230PF NSYCAG125LPF E
NSYCAF223L55 NSYCVF165M230PF NSYCAG223LPF A D F
NSYCAF223L55 NSYCVF300M230PF NSYCAG223LPF
NSYCAF291L55 NSYCVF560M230PF NSYCAG291LPF
NSYCAF291L55 NSYCVF850M230PF NSYCAG291LPF
415
ClimaSys CV Thermal management system
Accessories
Fans by components
Fans
PB501060-75
Accessories
Dimensions (mm) Description References
124 x 124 x 11 mm Outlet grille NSYCAG108LP
- Filter NSYCAF108
DB300487EN-SE
termination cover
Ø 108
104.8
Protection
grille
Filter
117 44 Wall
11 104.8
Ventilation kit
PB501061
104.8
96
Ø4
96
104.8
Fan with hood, for floor-standing enclosures. A flow rate of 350 m3/h is obtained
with an outlet grille ref. NSYCAG291LPF, (cut-out 291 x 291 mm).
bb Ingress protection rating: IP54
bb Installation: installation and removal from the outside.
bb Electric power: 85 W.
bb Noise level: 64 dB (A).
bb Supply: delivered with mountings and connection terminal block.
416
ClimaSys CV Thermal management system
Accessories
Fans by components
PB501064-32
PB501065-34
PB501063-33
Characteristics Fan motor Outlet grille Rear protective grille
Turbine-type fan motor for Outlet filter kit for enclosure Protective grille for enclosure
ventilation/extraction. ventilation. fan motor.
For coupling to fans For coupling to fans
NSYCVF156M●●● and NSYCVF156M●●● and
NSYCVF35M●●●. NSYCVF35M●●●.
Flow rate Voltage Absorbed Noise External References
(m3/h) (V) power (W) level (dB) dimensions
(mm)
156 230/50-60 17/15 42 120 x 120 x 38 NSYCVF156M230 NSYCAG114LPF NSYCVA114M
120/50-60 17/15 42 120 x 120 x 38 NSYCVF156M115 NSYCAG114LPF NSYCVA114M
35 230/50-60 16/14 32 80 x 80 x 25 NSYCVF35M230 NSYCAG78LPF NSYCVA78M
120/50-60 16/14 32 80 x 80 x 25 NSYCVF35M115 NSYCAG78LPF -
DB300489EN-92
Reference
NSYCVAC100
417
ClimaSys CV Thermal management system
Accessories
PB501067-53
Characteristics Circulation fan
User protection according to DIN 31001.
Dimensions:
bb Fan: 119 x 119 x 38 mm.
bb Collar: length: 140 mm; mounting centre-to-centre distance:
130 mm.
bb Installation on ball-bearing.
Supply -
Flow rate Voltage No. Weight P I dB Depth References
(m3/h) (V) (kg) (W) (mA) (A) (mm)
170 (1) 115 - 0.82 17 - 41 - NSYCVF170M115
230 - 0.82 17 - 41 - NSYCVF170M230
300 (2) 230 - - 37 - - - -
(50-60 Hz)
486 (2) 230 3 3.3 45 300 43 208 -
972 (2) 230 6 5.5 90 600 44 330 -
1458 (2) 230 9 7.8 135 900 45 452 -
552 (2) 48 (3) 3 3.3 21.3 330 43 208 -
(1) Free flow.
(2) Flow rate measured without counter-pressure.
(3) Direct current.
418
ClimaSys CV Thermal management system
Accessories
Circulating
PB501070-52
PB501069-52
PB501068-49
- -
- -
NSYAVG2U300 -
- NSYAVD1U480
- NSYAVD1U970
- NSYAVD1U1450
- NSYAVD1U550M48
419
ClimaSys CA Thermal management system
Accessories
Natural airing
PB501072-54
Characteristics Metal louvre plate, rectangular
Material Steel
Finish Painted with epoxy-polyester resin, textured RAL 7035 grey
Ingress protection rating IP20
Installation On the sides of the enclosure. Mounting by screws
Supply 1 metal louvre and mounting elements
Dimensions A B C D E F G H R Slot width No. of References
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) slots
- 144 62 36 110 - - 110 46 10 - - NSYCAG110X46M
- 208 90 72 94 190 - 180 62 18 - - NSYCAG180X62M
- 244 90 72 130 226 - 216 62 18 - - NSYCAG216X62M
- 345 118 100 231 327 115.5 317 90.5 30 - - NSYCAG317X91M
- 345 148 130 231 327 115.5 317 120 30 - - NSYCAG317X120M
- 445 148 130 267 427 148.5 417 120 30 - - NSYCAG417X120M
120 x 120 95 104 104.8 - - - - - - 90 5 -
160 x 160 110 130 140 - - - - - - 100 5 -
220 x 220 190 170 200 - - - - - - 180 5 -
A
DB300493EN-34
F F H
DB300494-30
= =
C R
G
B
Ø 5.3 D
E
PB501062-30
PB501071-30
PB500594-23
DB300491-73
DB300492-23
7
Ø
Ø
6
6
16.5
228
240
18.9
190
290,5
290,5
228
228
270
340
270
340
270
270
Ø7
21.8
H
M12
Spare filter
Reference
NSYCAF228R
420
ClimaSys CA Thermal management system
Accessories
Natural airing
PB500769-38
PB501073-29
Metal louvre plate, square Anti-insect filters for metal louvre plate, square
- Stainless-steel 304L Ø 0.32 mm wire mesh, of 1.07 mm, thickness 0.6 mm
- -
IP23 IP33
- Between the enclosure and the metal louvre
One metal louvre One anti-insect filter
External dimensions Weight References
(mm) (kg/m2)
- - - -
- - - -
- - - -
- - - -
- - - -
- - - -
NSYCAG104X95LM 98 x 115 0.8 NSYCAF104X95X
NSYCAG130X110LM 133 x 158 0.8 NSYCAF130X110X
NSYCAG170X190LM 197 x 215 0.8 NSYCAF170X190X
DB300495-25
C
B
Ø4
A
C
PB501076-28
PB501078-21
PB501075-8
PB501077-11
421
ClimaSys CV Thermal management system
Selection guide
DB300457-59
Fan flow rate (m3/h) Voltage Type of connection
Free With 1 fan + With 1 fan + C = by cable
with filter 1 outlet grille 2 outlet grille F = by faston (1)
B = by terminal block
50 Hz 50 Hz 50 Hz
38 25 33 230 V C
PB501050-27
38 27 35 115 V C
58 39 47 24 V DC C
44 34 41 48 V DC C
85 63 71 230 V F
PB501051-34
79 65 73 115 V F
80 57 77 24 V DC F
79 59 68 48 V DC F
(1) Fan models with connection type (F) are delivered with the connection cord included (2 metres).
422
ClimaSys CV Thermal management system
Selection guide
268 x 248 223 x 223 NSYCVF165M230PF NSYCAG223LPF NSYCAG223LPC NSYCAP223LZF NSYCAP223LXF NSYCAP223LE
NSYCVF165M115PF
NSYCVF165M24DPF
NSYCVF165M48DPF
NSYCVF300M230PF
NSYCVF300M115PF
NSYCVF300M24DPF
NSYCVF300M48DPF
336 x 316 291 x 291 NSYCVF560M230PF NSYCAG291LPF NSYCAG291LPC NSYCAP291LZF NSYCAP291LXF NSYCAP291LE
NSYCVF560M115PF
NSYCVF850M230PF
NSYCVF850M115PF
NSYCVF850M400PF
423
ClimaSys CE Thermal management system
Introduction
PB502596-48
advantage of cooler ambient tem- improved design
With an updated external grill design, and by
peratures, such as food and beverage positioning cooling closer to critical equipment, such
as speed drives, ClimaSys now provides better flow,
plants, to evacuate large amounts of better cooling, and higher energy efficiency.
heat while guaranteeing the inde-
pendence of the internal
and external air circuits. PB500011SE
Simplicity saves you time
Our free ProClima thermal calculation software
makes specification simple and fast. A new thermal
solutions module integrates calculation for cooling and
control devices, helping you maximize the energy
PB502596-36
Faster installation
A number of design improvements reduce
installation time. Mounting requires single cutouts
and a minimum of screws. Wiring is accomplished
with smart interconnects.
Protection
All side-mounted models are IP55 internally
424
ClimaSys CE Thermal management system
Characteristics
PB502619-19
PB502596-18
PB502618-15
425
ClimaSys CE Thermal management system
Dimensions
316
Side-mounting models
NSYCEA14E
185
DB300817EN
188 165
771
18
145 20
Ø 8 (4x)
124 50 105
145 20
360
325
363
55
10
120
20 25
20
NSYCEA36 / NSYCEA50
NSYCEA14E NS
316 93
DB300817EN
50 45
66
1260
145
175
510
188 165 185
8.5 295
771
18
145 20
771
Ø 8 (4x)
124 50 105
145 20
150
360
325
Ø 8 (4x)
160
56 30
Ø
55
10 23.5 265
120
20 25 312
20
314
158.5 30 32 15 15
64
261
184
21
220
93 Ø 8 (4x)
21 3150 150 50
50 45
66
608
1258
1260
765
145
175
510
125
150
40
15
Ø 8 (4x)
202
160
56 30 30
Ø Ø
23.5 265 69
312 27 260
426
ClimaSys CE Thermal management system
Introduction
PB502606-30
where there is no external air circuit the right fit
Air-water exchangers offer roof and side mounting
available but a stable cold-water options.
circuit can be supplied.
PB502608-36
to any application
Air-water exchangers can be provided in the same
material as electrical enclosures for (for example
stainless steel) a homogeneous appearance and
thermal performance.
bb UL,
bb CE.
Protection
PB502607-13
427
ClimaSys CE Thermal management system
Characteristics
PB502608-18
PB502593-17
PB502607-13
428
ClimaSys CE Thermal management system
Characteristics
PB502622-34
PB502609-20
PB502606-24
Top-mounting
model
1450 m³/h 1450 m³/h 2420 m³/h 2420 m³/h 2900 m³/h 2900 m³/h 750 m³/h
Filtered water or Filtered water or Filtered water or Filtered water or Filtered water or Filtered water or Filtered water or
glicolised water glicolised water glicolised water glicolised water glicolised water glicolised water glicolised water
800 l/h 800 l/h 2000 l/h 2000 l/h 2000 l/h 2000 l/h 500 l/h
0.5 bar 0.5 bar 3.5 bar 3.5 bar 4.8 bar 4.8 bar 0.3 bar
3/4" G 3/4" G 3/4" G 3/4" G 3/4" G 3/4" G 1/2" G
1 x 230 V / 50-60 Hz* 2 x 400-440V / 1 x 230 V / 50-60 Hz 2 x 400-440V / 1 x 230 V / 50-60 Hz 2 x 400-440V / 1 x 230 V / 50-60 Hz
50-60 Hz 50-60 Hz 50-60 Hz
0.71 A 0.4 A 1.2 A 0.75 A 1.4 A 0.9 A 0.30 A
160 W 170 W 260 W 280 W 320 W 420 W 65 W
T2 A T1 A T2 A T2 A T4 A T2 A T2 A
1500 x 450 x 163 mm 1500 x 450 x 163 mm 1932 x 797 x 206 mm 1932 x 797 x 206 mm 1932 x 797 x 206 mm 1932 x 797 x 206 mm 270 x 400 x 542 mm
IP55 / IP55 IP55 / IP55 IP55 / IP55 IP55 / IP55 IP55 / IP55 IP55 / IP55 IP54 / IP55
429
NSYCEW..15K..
P (W) 70000
ClimaSys CE
60000
50000 4
Thermal management system
Dimensions
5°C
40000
Ti
30000
35°C
20000 25
°C
10000
2000 l\h
0
5 7.5 10 12.5 15 17.5 20
New
Ta (°C)
Air-water exchangers
Side-mounting models 19
398
360
137
68.5
19
74
360
250
14 105 300 110
30
29
22
28
NSYCEW••1K••
34
Performance curves
46
DB300818EN
NSYCEW..1K..
270
280
294
310 115
296
P (W) 2800 30 250
400
400
DB300822EN
12
197.7
25
2400
Ø 7 (4x) Ø 25
80 125 125
20
228.5
2000
901
45°C 69 405
375
22.7 496 238.5
450
450
1600 542.2
Ti
1200 35°C
270
176
Ø 7.5 (4x)
53
50
800 25°C
60 27.7 25 240
35 310
400
540 Ø 7.5
150 l\h
Water flow
0 39 320
5 7.5 10 12.5 15 17.5 20 120 30 398
Ta (°C)
NSYCEW..1K8.. NSYCEW..10K..
P (W) 4000 NSYCEW2K5R P (W) 70000
NSYCEW..1K.. NSYCEW..1K8.. - NSYCEW..2K5
45 60000
3500 °C
NSYCEW..6K..
NSYCEW••1K8•• – NSYCEW••2K5••
50000 398 163
Performance
3000
P (W) 14000 curves 19 360 80
NSYCEW..1K8..
398 13740000 4NSYCEW..10K..
DB300818EN
19
5°C 360 22.5
DB300822EN
35
110 2500
1200035° 74
30
29
22
C 45°
C 30000 450
45 60000
°
10000 C
3500
2000 100 250
450 163
20000
20
45 360 80 50000 35°C 67
280
294
75
310 115
296
25°C
8000
3000
1500 30 T 250 200 l\h 25°C
155 35°C 68.5 i
25 35.7 10000
12
4000
20
350
228.5
831
901
5
304
1148
375
238.5 20000
450
450
.2 2000
25°C 35°C
800 l\h
1500 200 l\h 25°C
10000
0 150 l\h 2000 l\h
5 7.5 10 12.5 15 17.5 20 100 l\h
176
Ø 34
860
1000 T (°C) Ø 7.5 (4x) 0
12.5a 15
53
631
39 320
1500
1500
1932
120 30 398 Ø 7 (6x)
7000 60000
45
°C
Water flow 120 42 25
6000 50000 4
5° C
5000 NSYCEW..2K5../NSYCEW2K5R 40000
NSYCEW..15K..
P (W) 8000 NSYCEW..1K..
Ti NSYCEW..1K8..
P (W) 70000 - NSYCEW..2K5.. Ti NSYCEW
180
4000 35 30000
7000 °C 60000 35
45 °C
600
°C
3000 20000 25
6000 50000 4 °C
5°C 797 206
2000 500 l\h 46
10000
5000 25°C 400 l\h 40000 22.5 752 2000 l\h 103
Ti 300 l\h Ti
1000 0
40005 35 7.5
°C
10 12.5 15 17.5 20 450 30000 5 7.5 10 12.5 15 17.5 20
450 Ta (°C) 163 100 250 35°C Ta (°C)
3000 20000 25 65 320
20
45 360 80 67 120 39 25
75
°C 410 20
220
NSYCEW..3K5.. NSYCEW..1K..
P (W) 9000 P (W) 2800
Ø 34 NSYCEW..6K..
860
8000 2400
45°
C
7000 2000
45°C
6000 NSYCEW..3K5.. NSYCEW..1K..
1077
1600
631
1500
1932
300 l\h
2000 0
5 7.5 10 12.5 15 17.5 20 5 7.5 10 12.5 15 17.5 20
Ta (°C)
65 320
Units of measurement are mm. Ta (°C)
120 39 25
410 20
193
NSYCEW..4K5.. NSYCEW..6K..
P (W) 10000 P (W) 14000
430
9000 180 37.5 40 43.5
12000
45° 45°
C C
8000
5000 NSYCEW..2K5../NSYCEW2K5R 40000 NSYCEW..15K..
P (W) 50000
8000 Ti P (W) 70000 Ti
4000 35 30000
°C
7000
40000 60000 35°C
4545°C
ClimaSys CE
3000 20000 25
6000
30000 50000 4 °C
500 l\h 5°C
2000 2 10000
5°C 400 l\h 2000 l\h
Dimensions
5000
20000 300 l\h 40000
35°C Ti Ti
1000 0
4000 3525°C7.5
5
10000
10 12.5 15 17.5 20 30000 5 7.5 10 12.5 15 17.5 20
°C 2000 l\h
Ta (°C) 35°C Ta (°C)
30000 20000 25
5 7.5 10 12.5 15 17.5 20 °C
2000 2 Ta (°C) 500 l\h
5°C 400 l\h 10000
2000 l\h
300 l\h
1000 0
5 7.5 10 12.5 15 17.5 20 5 7.5 10 12.5 15 17.5 20
Ta (°C) Ta (°C)
NSYCEW..3K5.. NSYCEW..1K..
New
P (W) 9000 P (W) 2800
DB300818EN
6000 NSYCEW..3K5.. 398 163
1600 NSYCEW..1K..
61 276
21
19
28
P (W) 50000
9000 Ti 360 80 2800
P (W) Ti
DB300822EN
4
398 5000 3 5°C 137 19 360 1200 35°C
19 36040000 5°C 68.5 250
35
8000 74 2400
30
Ti
4000 45°C 800 25°C
7000 2000
315
30000
3000 2 35°C 500 l\h 400 45°C
5°C 400 l\h 150 l\h
296
6000 1600
555
20000 25°C Ti 300 l\h Ti
2000 0
50005 3
10000
7.5 10 12.5 15 17.5 20 12005 7.5
35°C 10 12.5 15 17.5 20
5°C 2000 l\h
Ta (°C) Ta (°C)
40000 800 25°C
228.5
831
901
1148
1148
454
19 360 68.5
3000 2 Ta (°C) 14500 l\h
105 300 110 400
29
22
28
2000 0
46
270
280
Ta (°C) Ta (°C)
294
310 115 30 250
400
400
155 68.5
555
25 35.7
12
NSYCEW..4K5.. NSYCEW..6K..
180
197.7
25
P (W) 10000 P (W) 14000
DB300822EN
Ø 7.5 (4x)
Ø 7 (4x) Ø 25
80 125 125
9000
20
12000
45°NSYCEW..1K.. 39 320 45° Ø 7 (6x)
C
901
P (W) 2800 69 405 C
120 22.7 30 398
375
8000 496 450 238.5
450
542.2 10000
2400
7000 120 42 25 39 320
NSYCEW..4K5.. 8000 NSYCEW..6K..
270
53
50
7 Ta (°C) 2000
3000 400 l\h 800 l\h
220
300 l\h
2000 0
5 7.5 10 12.5 15 17.5 20 5 7.5 10 12.5 15 17.5 20
Ta (°C) Ta (°C)
NSYCEW••6K••
Performance curves
862
450
DB300818EN
NSYCEW..6K..
P (W) 14000 450 163 100 250
DB300822EN
20
Ø 34 67
860
45 360 80
75
12000
45°
C
10000 Ø 9 (6x)
1077
350
8000
1500
304
1932
1932
Ø 7 (6x) 35°C Ti
6000
25°C
4000
Ø 34
860
2000
800 l\h
0
600
862
Ta (°C)
1500
1500
Ø 7 (6x)
320
320
410 20
193
180
600
NSYCEW..10K.. -39
NSYCEW..15K..25 65 320
120
410 20
Water flow
NSYCEW..6K..
431
31
296
30 250
555
Thermal management system
25 35.7
12
ClimaSys CE
25
80 125 125
Dimensions
228.5
901
831
901
1148
1148
454
375
238.5
450
176
Ø 7.5 (4x)
53
555
240
180
35 310
Ø 7.5 (4x)
39 320 Ø 7 (6x)
120 30 398
New
P (W) 70000
NSYCEW..10K..
120 42 25 39 320
CEW..1K..
60000
NSYCEW..1K8.. - NSYCEW..2K5..
NSYCEW••10K•• – NSYCEW••15K•• NSYCEW..3K5.. - NSYCEW..4K5..
50000
Performance curves
DB300818EN
NSYCEW..10K..
P (W) 40000
70000 45°C
DB300822EN
Ti 797
30000
60000 797 206
46 705
22.5 752 103
20000
50000
35°C
25°C 450
3 10000 100
40000 45°C 250 Ti 2000 l\h
20
67
75
0
30000
5 7.5 10 12.5 15 17.5 20
220
Ta (°C)
20000
35°C
25°C
350
10000
2000 l\h
304
862
5 7.5 10 12.5 15 17.5 20
Ta (°C)
Ø 34
860
NSYCEW..15K..
P (W) 70000
DB300822EN
60000
Ø 9 (6x)
1077
631
1500
50000 4
1932
1932
5°C Ø 7 (6x)
NSYCEW..15K..
40000
P (W) 70000 Ti
30000
60000
35°C
20000
50000 25
45°C
180
°C
10000
600
40000
862
Ti 2000 l\h
0 NSYCEW..1K8..
30000
NSYCEW..10K..
P (W) 4000 5 3 7.5 10 12.5 15 17.5 20 P (W) 70000
5°C
Ta (°C)
320
20000 4 25
3500 5 °C°C 60000
10000
2000 l\h 50000
65
3000 320
25
0 410 20
193
104.5
2000 NSYCEW..1K..
P (W) 2800 20000
25°C Water flow 35°C
1500 200 l\h 25°C
2400 10000
150 l\h 2000 l\h
100 l\h
1000
2000 0
YCEW..6K.. 5 7.5 10 12.5 15 17.5 20 5 7.5NSYCEW..10K..
10 12.5 15- NSYCEW..15K..
17.5 20
45°C
NSYCEW..1K..
Ta (°C) Ta (°C)
1600
P (W) 2800 Ti
1200
2400 35°C
Top-mounting models
800
2000 25°C
45°C NSYCEW2K5R
400
1600 150 l\h
Performance curves Ti
DB300818EN
0 NSYCEW..2K5../NSYCEW2K5R
35°C NSYCEW..15K..
1200
P (W) 8000 5 7.5 10 12.5 15 17.5 20 P (W) 70000
34
DB300822EN
46
Ta (°C)
800 25°C Water flow
7000 60000
270
280
294
45 310 115 30
400
400
°C
400 155 68.5 2
6000 150 l\h 50000 4
197.7
25
5°C
0 Ø 7 (4x)
5000 5 Ø 25
80 125 125
Ti Ti
Ta (°C)
69 405
4000 35 22.7 496 30000
450
°C
35°C
542.2
NSYCEW..6K..
P (W) 3000
14000 20000 25
°C
270
C 300 l\h
1000
10000 0 60 27.7 25 35
5 7.5 10 12.5 15 17.5 20 5 7.5 10 12.5 15 17.5 20
NSYCEW..6K.. 540
Ta (°C) Ta (°C)
8000
P (W) 14000
35°C Ti
6000
12000
45
25°°C
C
4000
10000
Ta= Inlet water temperature
Ti= Desired
2000
8000 internal temperature of the enclosure
Ti 800 l\h NSYCEW2K5R NSYCEW..1K..
35°C
0 NSYCEW..3K5.. NSYCEW..1K..
6000
P (W) 9000 5 7.5 10 12.5 15 17.5 20 P (W) 2800
25°C Ta (°C)
4000
8000 2400
45
2000 °C
7000 800 l\h 2000
45°C
0
6000 5 7.5 10 12.5 15 17.5 20 1600
Ti Ti
Ta (°C) 450 163
5000 3 1200 35°C
5°C 45 360 80
4000 Units of measurement are mm. 800 25°C
New
PB502593-20
PB502657-36
Characteristics Air-air and air-water exchangers Retrofit panel
CE UL / CE
Steel Stainless steel Steel Stainless steel
Panel that enable to mount a new ClimaSys CE or
CU units by replacement of old Schneider Electric
cooling systems.
Material Metal painted
Colour RAL 7035
Supply 1 unit
References Retrofit panel Old Schneider Electric
cooling system
Air- air exchangers
Side-mounting models NSYCEA14E - - - NSYCEARTFIT14 NSYCEA15W230VL
NSYCEA36 - - - NSYCEARTFIT36 NSYCEA35W230VL
NSYCEA35W230VLE
NSYCEA50 - - - - -
NSYCEA80 - - - NSYCEARTFIT80 NSYCEA70W230VL
Air-water exchangers
Side-mounting models NSYCEW1K NSYCEWX1K NSYCEW1KUL NSYCEWX1KUL - -
NSYCEW1K8 NSYCEWX1K8 NSYCEW1K8UL NSYCEWX1K8UL - -
NSYCEW2K5 NSYCEWX2K5 NSYCEW2K5UL NSYCEWX2K5UL NSYCEWRTFIT2K5 NSYCEW2100W230VL
NSYCEW3K5 NSYCEWX3K5 NSYCEW3K5UL NSYCEWX3K5UL NSYCEWRTFIT3K5 NSYCEW3150W230VL
NSYCEW4K5 NSYCEWX4K5 NSYCEW4K5UL NSYCEWX4K5UL - -
NSYCEW6K NSYCEWX6K NSYCEW6KUL NSYCEWX6KUL - -
NSYCEW6K2P4 NSYCEWX6K2P4 NSYCEW10K NSYCEWX10K - -
NSYCEW10K2P4 NSYCEWX10K2P4 - - - -
NSYCEW15K NSYCEWX15K - - - -
NSYCEW15K2P4 NSYCEWX15K2P4 - - - -
Top-mounting model NSYCEW2K5R - - - - -
433
ClimaSys CU Thermal management system
Introduction
Choose cooling units for harsh Many mounting options give you
PB502631
environments, where ambient the right fit
Cooling units range offer roof and side mounting
temperatures can reach up to 55°C. options as well as slim models for efficient and
space-saving installation on control panel doors.
The unit’s integrated alarm system
will signal you in the event
of any operational anomaly. Extended ratings to meet any challenge
Provide options for up to 15 kW of cooling power.
15 kW
PB502625-27
PB502632-20
application
ClimaSys cooling units offer new outdoor and stainless
steel versions, ideal for clean, hygienic environments
such as food and beverage plants.
bb UL,
bb CE.
Simplicity
PB502660-32
435
ClimaSys CU Thermal management system
Characteristics
PB502595-17
PB502614-15
PB502613-13
Characteristics PB502617-21
Side-mounting models
Cooling units for electrical control panels.
bb Respect for the environment by using environmentally friendly gas R134a (HFC).
bb Electronic thermostats in all models.
bb Alarm signal for door contact included in all models.
bb Eyebolts included.
bb Among best in class components.
bb The external filter, not included as standard, is strongly recommended for harsh environments.
bb HMI screen.
Material RAL 7035 grey painted zinc-coated steel or stainless steel
Certifications bb CE declaration
bb UL (only references ending with UL)
Installation Indoor
Cooling characteristics
Cooling power L35-L35 300 W (1024 Btu/h) 380 W (1297 Btu/h) 640 W (2184 Btu/h) 820 W (2798 Btu/h)
Cooling power L35-L50 150 W (512 Btu/h) 240 W (819 Btu/h) 470 W (1604 Btu/h) 680 W (2320 Btu/h)
Air flow of the internal circuit (enclosure) 280 m³/h 280 m³/h 330 m³/h 330 m³/h
Air flow of the external circuit (ambient) 280 m³/h 280 m³/h 570 m³/h 570 m³/h
Thermostat type Electronic Electronic Electronic Electronic
Temperature setting range +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C
Maximum outside temperature +55°C +55°C (+50°C)** +55°C (+50°C)** +55°C (+50°C)**
Temperature range external circuit (ambient) +20 … +55°C* +20 … +55°C* +20 … +55°C* +20 … +55°C*
(+20 … +50°C)** (+20 … +50°C)** (+20 … +50°C)**
Type of cooling gas R134a R134a R134a R134a
Cooling gas weight 0.13 kg 0.16 kg 0.23 kg 0.23 kg
Maximum pressure cooling circuit 25 bar 26 bar (28 bar)** 25 bar (28 bar)** 25 bar (28 bar)**
External filter Optional, Optional, Optional, Optional,
see page 451 see page 451 see page 451 see page 451
Electric characteristics
Input voltage 1 x 230 V / 50-60 Hz 1 x 230 V / 50-60 Hz** 1 x 230 V / 50-60 Hz** 1 x 230 V / 50-60 Hz**
Starting / Rated Intensity 4.2 A / 1.5 A 6.0 A / 1.6 A 8.1 A / 2.1 A 10.8 A / 2.6 A
Power consumption absorved L35-L35 270 W 280 W 400 W 440 W
Power consumption absorved L35-L50 310 W 330 W 470 W 490 W
Energy efficiency ratio (EER) L35-L35 1.1 1.4 1.6 1.9
Thermal protection recommended (fuse) T4 A T4 A T6 A T6 A
Physical characteristics
External dimensions (H x W x D) 340 x 525 x 135 mm 460 x 285 x 180 mm 606 x 316 x 212 mm 783 x 348 x 215 mm
Protection degree IP internal /external IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34
Noise level 61 dB 60 dB 65 dB 65 dB
Weight of unit 17 kg 17 kg 21 kg 27 kg
References
Steel NSYCU300H NSYCU400 NSYCU600 NSYCU800
Stainless steel - NSYCUX400 NSYCUX600 NSYCUX800
Steel UL - NSYCU400UL NSYCU600UL NSYCU800UL
Stainless steel UL - - NSYCUX600UL NSYCUX800UL
* 50°C at 60 Hz.
** Certification UL only 60 Hz.
436
ClimaSys CU Thermal management system
Characteristics
PB502615-19
PB502595-17
1000 W (3412 Btu/h) 1000 W (3412 Btu/h) 1250 W (4265 Btu/h) 1250 W (4265 Btu/h) 1600 W (5459 Btu/h) 1600 W (5459 Btu/h) 2000 W (6824 Btu/h)
790 W (2696 Btu/h) 790 W (2696 Btu/h) 910 W (3105 Btu/h) 910 W (3105 Btu/h) 1230 W (4197 Btu/h) 1230 W (4197 Btu/h) 1510 W (5152 Btu/h)
330 m³/h 330 m³/h 570 m³/h 570 m³/h 570 m³/h 570 m³/h 860 m³/h
570 m³/h 570 m³/h 860 m³/h 860 m³/h 1050 m³/h 1050 m³/h 1050 m³/h
Electronic Electronic Electronic Electronic Electronic Electronic Electronic
+20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C
+55°C (+50°C)** +55°C (+50°C)** +55°C (+50°C)** +55°C +55°C (+50°C)** +55°C (+50°C)** +55°C (+50°C)**
+20 … +55°C* +20 … +50°C +20 … +55°C* +20 … +50°C +20 … +55°C* +20 … +50°C +20 … +55°C*
(+20 … +50°C)** (+20 … +50°C)** (+20 … +50°C)** (+20 … +50°C)** (+20 … +50°C)**
R134a R134a R134a R134a R134a R134a R134a
0.23 kg 0.23 kg 0.38 kg 0.38 kg 0.45 kg 0.45 kg 0.54 kg
25 bar (28 bar)** 25 bar (28 bar)** 25 bar (28 bar)** 25 bar 25 bar (28 bar)** 25 bar (28 bar)** 25 bar (28 bar)**
Optional, Optional, see page 451 Optional, Optional, Optional, Optional, Optional,
see page 451 see page 451 see page 451 see page 451 see page 451 see page 451
783 x 348 x 215 mm 783 x 348 x 215 (+58) mm 999 x 405 x 237 mm 999 x 405 x 237 mm 999 x 405 x 237 mm 999 x 405 x 237 mm 999 x 405 x 237 mm
IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34
65 dB 65 dB 65 dB 65 dB 65 dB 65 dB 65 dB
28 kg 29 kg 38 kg 40 kg 40 kg 42 kg 52 kg
437
ClimaSys CU Thermal management system
Characteristics
PB502625-21
PB502616-17
PB502615-13
438
ClimaSys CU Thermal management system
Characteristics
PB502627-27
PB502626-28
PB502625-21
bb Indoor
bb Cannot be installed with enclosures with plinths
6050 W (20643 Btu/h) 7600 W (25932 Btu/h) 7950 W (27126 Btu/h) 9400 W (32074 Btu/h) 9850 W (33610 Btu/h) 14800 W (50500 Btu/h) 15150 W (51694 Btu/h)
4350 W (14843 Btu/h) 5700 W (19449 Btu/h) 5930 W (20234 Btu/h) 7000 W (23885 Btu/h) 7350 W (25079 Btu/h) 11300 W (38557 Btu/h) 11600 W (39581 Btu/h)
1450 m³/h 2900 m³/h 2900 m³/h 2900 m³/h 2900 m³/h 4300 m³/h 4300 m³/h
2900 m³/h 2900 m³/h 2900 m³/h 2900 m³/h 2900 m³/h 5800 m³/h 5800 m³/h
Electronic Electronic Electronic Electronic Electronic Electronic Electronic
+20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C
+50°C +50°C +50°C +50°C +50°C +55°C +55°C
+20 … +50°C +20 … +50°C +20 … +50°C +20 … +45°C +20 … +45°C +20 … +50°C +20 … +50°C
3 x 460 V / 60 Hz 3 x 400 V / 50 Hz 3 x 460 V / 60 Hz 3 x 400 V / 50 Hz 3 x 460 V / 60 Hz 3 x 400 V / 50 Hz 3 x 460 V / 60 Hz
23.5 A / 6.8 A 43.8 A / 7.2 A 44.5 A / 7.9 A 30.7 A / 9.1 A 32.5 A / 10.3 A 49 A / 11 A 51 A / 11.8 A
2920 W 3530 W 4210 W 3850 W 4380 W 5750 W 6580 W
4520 W 4270 W 5340 W 5400 W 6340 W 6900 W 7760 W
2.1 2.2 1.9 2.4 2.2 2.6 2.3
T8 A T10 A T10 A T18 A T18 A T20 A T20 A
2000 x 600 x 380 mm 2000 x 800 x 380 mm 2000 x 800 x 380 mm 2000 x 800 x 380 mm 2000 x 800 x 380 mm 2000 x 800 x 550 mm 2000 x 800 x 550 mm
IP54 / IP34 IP54 / IP34 IP54 / IP34 IP54 / IP34 IP54 / IP34 IP54 / IP34 IP54 / IP34
72 dB 72 dB 72 dB 77 dB 77 dB 67 dB 67 dB
150 kg 160 kg 160 kg 180 kg 180 kg 240 kg 240 kg
439
ClimaSys CU Thermal management system
Characteristics
PB502611-26
PB502594-26
PB502610-21
Characteristics Top-mounting models
Cooling units for electrical control panels.
bb Respect for the environment by using environmentally friendly gas R134a (HFC).
bb Alarm signal for door contact included in all models.
bb Eyebolts included.
bb Among best in class components.
bb The external filter, not included as standard, is strongly recommended for harsh environments.
Material RAL 7035 grey painted zinc-coated steel or stainless steel
Certifications bb CE declaration
bb UL (only references ending with UL)
Installation Indoor
Cooling characteristics
Cooling power L35-L35 410 W (1399 Btu/h) 820 W (2798 Btu/h) 1150 W (3924 Btu/h)
Cooling power L35-L50 240 W (819 Btu/h) 680 W (2320 Btu/h) 900 W (3071 Btu/h)
Air flow of the internal circuit (enclosure) 235 m³/h 570 m³/h 570 m³/h
Air flow of the external circuit (ambient) 330 m³/h 860 m³/h 1010 m³/h
Thermostat type Electronic Electronic Electronic
Temperature setting range +20 … +46°C +20 … +46°C +20 … +46°C
Maximum outside temperature +55°C +55°C +55°C
Temperature range external circuit (ambient) +20 … +55°C* +20 … +55°C* +20 … +55°C*
(+20 … +50°C)** (+20 … +50°C)** (+20 … +50°C)**
Type of cooling gas R134a R134a R134a
Cooling gas weight 0.17 kg 0.31 kg 0.63 kg
Maximum pressure cooling circuit 28 bar 25 bar (28 bar)** 25 bar (28 bar)**
External filter Optional, see page 451 Optional, see page 451 Optional, see page 451
Electric characteristics
Input voltage 1 x 230 V / 50-60 Hz** 1 x 230 V / 50-60 Hz** 1 x 230 V / 50-60 Hz**
440
ClimaSys CU Thermal management system
Characteristics
PB502612-35
PB502611-26
1550 W (5289 Btu/h) 2050 W (6995 Btu/h) 2050 W (6995 Btu/h) 2900 W (9895 Btu/h) 3850 W (13137 Btu/h)
1200 W (4095 Btu/h) 1560 W (5323 Btu/h) 1560 W (5323 Btu/h) 2250 W (7677 Btu/h) 2870 W (9793 Btu/h)
860 m³/h 1050 m³/h 1050 m³/h 860 m³/h 1450 m³/h
1820 m³/h 1820 m³/h 1820 m³/h 3410 m³/h 3410 m³/h
Electronic Electronic Electronic Electronic Electronic
+20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C
+55°C +55°C (+50°C)** +50°C (+45°C)** +50°C (+45°C)** +50°C (+45°C)**
+20 … +55°C* +20 … +55°C* +20 … +50°C +20 … +50°C +20 … +50°C
(+20 … +50°C)** (+20 … +45°C)** (+20 … +45°C)** (+20 … +45°C)**
R134a R134a R134a R134a R134a
0.54 kg 0.55 kg 0.55 kg 1.20 kg 1.60 kg
25 bar (28 bar)** 25 bar 25 bar (28 bar)** 25 bar (28 bar)** 25 bar (28 bar)**
Optional, Optional, Optional, Optional, see page 451 Optional, see page 451
see page 451 see page 451 see page 451
415 x 567 x 401 mm 415 x 567 x 401 mm 415 x 567 x 401 mm 496 x 797 x 492 mm 496 x 797 x 492 mm
IP54 / IP34 IP54 / IP34 IP54 / IP34 IP54 / IP34 IP54 / IP34
65 dB 65 dB 65 dB 75 dB 75 dB
44 kg 50 kg 52 kg 83 kg*** 86 kg***
*** To mount on roof of Spacial SF, it is mandatory to order the roof mounting support
(see table below).
models on Spacial SF
(cooling units with weight > 65 kg).
bb Material: steel.
bb Colour: RAL 7035.
PB502700-24
bb Supply: 2 units.
Depth 600 mm Depth 800 mm
NSYSUCR4060 NSYSUCR4080
441
ClimaSys CU Thermal management system
Characteristics
PB502680-17
PB502679-15
PB502678-14
Electric characteristics
Input voltage 1 x 230 V / 50-60 Hz 1 x 230 V / 50-60 Hz 1 x 230 V / 50-60 Hz
Starting / Rated Intensity 6.0 A / 1.6 A 8.1 A / 2.1 A 10.8 A / 2.6 A
Power consumption absorved L35-L35 280 W 400 W 440 W
Power consumption absorved L35-L50 330 W 470 W 490 W
Energy efficiency ratio (EER) L35-L35 1.4 1.6 1.9
Thermal protection recommended (fuse) T4 A T6 A T6 A
Physical characteristics
External dimensions (H x W x D) 460 x 285 x 180 mm 606 x 316 x 212 mm 783 x 348 x 215 mm
Protection degree IP internal /external IP55 / IP34 IP55 / IP34 IP55 / IP34
Noise level 60 dB 65 dB 65 dB
Weight of unit 17 kg 21 kg 27 kg
References
NSYCUHD400 NSYCUHD600 NSYCUHD800
442
ClimaSys CU Thermal management system
Characteristics
PB502677-19
PB502680-17
1000 W (3412 Btu/h) 1000 W (3412 Btu/h) 1600 W (5459 Btu/h) 1600 W (5459 Btu/h) 2000 W (6824 Btu/h) 2900 W (9895 Btu/h) 3850 W (13137 Btu/h)
790 W (2696 Btu/h) 790 W (2696 Btu/h) 1230 W (4197 Btu/h) 1230 W (4197 Btu/h) 1510 W (5152 Btu/h) 2250 W (7677 Btu/h) 2870 W (9793 Btu/h)
330 m³/h 330 m³/h 570 m³/h 570 m³/h 860 m³/h 1450 m³/h 1450 m³/h
570 m³/h 570 m³/h 1050 m³/h 1050 m³/h 1050 m³/h 1450 m³/h 1450 m³/h
Mechanic Mechanic Mechanic Mechanic Mechanic Mechanic Mechanic
+20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C
+55°C +55°C +55°C +55°C +55°C +55°C +55°C
-20 … +55°C -20 … +50°C -20 … +55°C -20 … +50°C -20 … +55°C -20 … +50°C -20 … +50°C
R134a R134a R134a R134a R134a R134a R134a
0.23 kg 0.23 kg 0.45 kg 0.45 kg 0.59 kg 0.84 kg 1.14 kg
25 bar 25 bar 25 bar 25 bar 25 bar 25 bar 25 bar
Optional, Optional, see metalic filter Optional, Optional, Optional, Optional, Optional,
see metalic filter on page 451 see metalic filter see metalic filter see metalic filter see metalic filter see metalic filter
on page 451 on page 451 on page 451 on page 451 on page 451 on page 451
1 x 230 V / 50-60 Hz 2 x 400-440V / 50-60 Hz 1 x 230 V / 50-60 Hz 2 x 400-440V / 50-60 Hz 3 x 400 V / 50-60 Hz 3 x 400 V / 50-60 Hz 3 x 400 V / 50-60 Hz
10.5 A / 3 A 8A/ 2A 18 A / 5.4 A 11 A / 2.9 A 10 A / 2.5 A 14 A / 2.6 A 18 A / 3.6 A
570 W 590 W 850 W 840 W 970 W 1220 W 1780 W
650 W 670 W 970 W 960 W 1150 W 1440 W 2050 W
1.8 1.7 1.9 1.9 2.1 2.4 2.2
T6 A T4 A T10 A T6 A T6 A T6 A T8 A
783 x 348 x 215 mm 783 x 348 x 215 (+58) mm 999 x 405 x 237 mm 999 x 405 x 237 mm 999 x 405 x 237 mm 1270 x 500 x 336 mm 1270 x 500 x 336 mm
IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34
65 dB 65 dB 65 dB 65 dB 65 dB 70 dB 70 dB
28 kg 29 kg 40 kg 42 kg 54 kg 84 kg 85 kg
443
ClimaSys CU Thermal management system
Characteristics
PB502631-17
444
ClimaSys CU Thermal management system
PB502632-17
Characteristics
2000 W (6824 Btu/h) 2000 W (6824 Btu/h) 2500 W (8530 Btu/h) 2500 W (8530 Btu/h) 3200 W (10919 Btu/h) 3200 W (10919 Btu/h)
1550 W (5289 Btu/h) 1550 W (5289 Btu/h) 1850 W (6312 Btu/h) 1850 W (6312 Btu/h) 2500 W (8530 Btu/h) 2500 W (8530 Btu/h)
860 m³/h 860 m³/h 1450 m³/h 1450 m³/h 1450 m³/h 1450 m³/h
1050 m³/h 1050 m³/h 1450 m³/h 1450 m³/h 1450 m³/h 1450 m³/h
Electronic Electronic Electronic Electronic Electronic Electronic
+20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C +20 … +46°C
+50°C +55°C* +50°C +55°C* +50°C +55°C*
(+50°C)** (+50°C)** (+50°C)**
+20 … +50°C +20 … +55°C* +20 … +50°C +20 … +55°C* +20 … +50°C +20 … +55°C*
(+20 … +50°C)** (+20 … +50°C)** (+20 … +50°C)**
R134a R134a R134a R134a R134a R134a
0.51 kg 0.59 kg 1.2 kg 1.2 kg 0.85 kg 1.25 kg
28 bar 28 bar 28 bar 28 bar 28 bar 28 bar
Optional, see page 451 Optional, see page 451 Optional, see page 451 Optional, see page 451 Optional, see page 451 Optional, see page 451
495 x 1696 x 195 mm 495 x 1696 x 195 mm 495 x 1696 x 235 mm 495 x 1696 x 235 mm 495 x 1696 x 235 mm 495 x 1696 x 235 mm
IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34 IP55 / IP34
67 dB 67 dB 69 dB 69 dB 69 dB 69 dB
63 kg 65 kg 78 kg 80 kg 78 kg 80 kg
445
ClimaSys CU Thermal management system
Dimensions
DB300819EN
262.5 67.7 142 207 100 26
100
275
258
340
340
211
Ø 7.5 (4x)
53
53
171.3 8.2 30 465
316
33.5 250
NSYCU••400•• NSYCU300H
285 180
DB300819EN
285
142.5 81.5 18.5 248
27
40
135 525
.7 142 207 100 26
606
100
460
460
417
393
275
258
340
211
Ø 7.5 (4x)
Ø 7.5 (4x)
53
53
30 465 12 261
405
27.5 350
26.5
NSYCU300H NSYCU••600•• NSYCU..400..
316 212
DB300819EN
316
33.5
33.5 250 101 47 222
12
783
384 35
86
999
606
606
Ø 7.5 (4x)
460
417
393
272
Ø 7.5 (4x)
27.5 350 110.5 52.5 300
12 261
30
38 240
248
267
NSYCU..400.. NSYCU..600..
NSYCU••800•• - NSYCU••1K••
DB300819EN
348 216
26.5 295 99.4 41 266
21
34
1270
230
NSYCU..
212 316
999
999
33.5
442
151
101
200
47 222
12
500 336
35 430 160 50 400
272
Ø 7.5 (6x)
212
45
252
783
413
783
384
199
86
41 323
606
Ø 9.5 (8x)
20.5
280
52.5 300
Ø 7.5 (4x)
30
272
290
62.5 280
405
248
267
38 240
49 250
NSYCU..1K2.. - NSYCU..1K6.. - NSYCU..2K.. 348
Units of measurement are mm.
1270
650
230
Ø 9.5 (8x)
171.3 8.2
DB300819EN
405 237 41 323
20.5
27.5 350 110.5 52.5 300
348
30
26.5 295
248
267
316 212 316
33.5
33.5 250 101 47 222
12
180 285
81.5 18.5 248
212
27
230
40
783
384
999
999
442
86
606
606
Ø 7.5 (4x)
460
417
393
272
272
Ø 7.5 (4x)
199
12 261 38 240 Ø 9.5 (8x)
NSYCU••3K3P4•• - NSYCU••4K3P4••
500 336
DB300819EN
50 400
25
35 430 160
45
23
20.5
280
00
407
267
1270
1270
407
650
999
442
Ø 9.5 (8x)
407
199
255
9.5 (8x)
80 45 410
05 500
NSYCU..3K3P4.. - NSYCU..4K3P4..
447
ClimaSys CU Thermal management system
Dimensions
DB300820EN
32.5
29.5 427 129.5 90 304
340
259
190
264
194
194
Ø 7.5 (4x)
35
108 170 124 67
13
NSYCU..400R..
NSYCU••800R••
600 340 34.5
DB300820EN
32.5
481 29.5 427 129.5 90 304
567 401 567
34.5
19.5
32.5
340
206
259
190
264
194
Ø 7.5 (6x)
340
340
270
194
254
Ø 7.5 (4x)
259
190
194
194
285
293
35
401
362
415
13
38
108 170 124 67
13
56 210 257 58
35
86
600
43
29.5 248 69 130 43
17
15
NSYCU..800R..
NSYCU..400R.. 35
400R..
567 453
34.5
19.5
340
44
34.5 240 240
544 170.5 45.5 275 260
Ø 7.5 (6x) Ø 7.5 (8x)
222.5
Ø 7.5 (6x)
285
293
270401
362
415
487
206
285
293
496
340
340
401
362
254
194
Ø 7.5 (6x)
222.5
43
38
95
43
56 210 257 58
17
15
35
86
145 80 213
15
35
21
21 777
NSYCU..800R..
NSYCU..1K2R.. - NSYCU..1K5R.. - NSYCU..2K..R..
U..1K5R.. - NSYCU..2K..R.. NSYCU..3K3P4R.. - NSYCU..4K3P4R..
NSYCU••3K3P4R•• - NSYCU••4K3P4R••
797 492 35 380 340
DB300820EN
Ø 7.5 (6x)
487
293
496
228
222.5
95
95
43
69 130 43
17
35
21
25
21
777
NSYCU..3K3P4R.. - NSYCU..4K3P4R..
448
ClimaSys CU Thermal management system
Dimensions
DB300848EN
38.5 418 161.5 33.5 430
300 10 80 65 65 300
38.5
191
210
400
400
1662.5
1632
1697
1620
450
400400
400
210
Ø 8 (x12)
195
NSYCUS•2K5• - NSYCUS•3K2•
460.5
DB300849EN
495
201.6 20.5
38.5 418 430
300 10 105 80 65 300 65
191
210
400
400
1662.5
1632
1697
1620
400
450
400
400
210
Ø 8 (x12)
235
449
ClimaSys CU Thermal management system
Accessories
New
PB502616-22
Material
Colour
Installation
Supply
References
Cooling units
Side-mounting models NSYCU300H - - - -
NSYCU400 NSYCUX400 NSYCUHD400 NSYCU400UL -
NSYCU2KR NSYCUX2KR - - -
NSYCU3K3P4R NSYCUX3K3P4R - NSYCU3K3P4RUL -
450
ClimaSys CU Thermal management system
Accessories
PB502657-24
PB502621-24
PB502620-23
PB502658-24
PB502647-37
Filters Canopy for Internal deflector Retrofit panel
ClimaSys CU
Plastic filter for Metalic filter for This canopy is highly Deflects the air inside the Panel that enable to mount a new ClimaSys CE or
ClimaSys Cu offer. ClimaSys Cu offer. recommended for harsh enclosure. CU units by replacement of old Schneider Electric
Not recommended Recommended for indoor environments to protect cooling systems.
for outdoor models. outdoor models. from ingress of dust.
Polyurethane Micro-stretched Painted zinc coated Zinc coated Metal painted
aluminium
Black - RAL 7035 RAL 7035 RAL 7035
Indoor Indoor or outdoor Indoor Indoor or outdoor Indoor
5 units 1 unit 1 unit 1 unit with mounting elements 1 unit
Old Schneider Electric
cooling system
- - - - - -
NSYCUF400 NSYCUFX400 NSYCUCN400HD NSYCUD400 NSYCURFT400 NSYCU240W230VL
NSYCU370W230VL
NSYCUF600 NSYCUFX600 NSYCUCN600HD NSYCUD600 - -
NSYCUF800T1K NSYCUFX800T1K NSYCUCN800T1KHD NSYCUD800T1K NSYCURFT800T1K NSYCU760W230VL
NSYCUF800T1K NSYCUFX800T1K NSYCUCN800T1KHD NSYCUD800T1K NSYCURFT800T1K NSYCUE1100W230L
NSYCUF800T1K NSYCUFX800T1K NSYCUCN800T1KHD NSYCUD1K2T2K NSYCURFT800T1K NSYCU1050W230VL
NSYCUF1KT2K NSYCUFX1K2T2K NSYCUCN1K2T2KHD NSYCUD1K2T2K - -
NSYCUF1KT2K NSYCUFX1K2T2K NSYCUCN1K2T2KHD NSYCUD1K2T2K - -
NSYCUF1KT2K NSYCUFX1K2T2K NSYCUCN1K2T2KHD NSYCUD1K2T2K NSYCURFT1K6T2K NSYCUE1400W230L
NSYCU1650W230VL
NSYCUF1KT2K NSYCUFX1K2T2K NSYCUCN1K2T2KHD NSYCUD1K2T2K NSYCURFT1K6T2K NSYCUE1400W400L
NSYCUF1KT2K NSYCUFX1K2T2K NSYCUCN1K2T2KHD NSYCUD1K2T2K - -
NSYCUF1KT2K NSYCUFX1K2T2K NSYCUCN1K2T2KHD NSYCUD1K2T2K NSYCURFT1K6T2K NSYCU1800W400VL
NSYCUE1800W400L
NSYCUF3KT4K NSYCUFX3KT4K NSYCUCN3KT4KHD NSYCUD3KT4K NSYCURFT3KT4K NSYCU2500W400VL
NSYCUF3KT4K NSYCUFX3KT4K NSYCUCN3KT4KHD NSYCUD3KT4K NSYCURFT3KT4K NSYCU4000W400VL
NSYCUF6K NSYCUFX6K - - - -
NSYCUF6K NSYCUFX6K - - - -
NSYCUF8KT10K NSYCUFX8KT10K - - - -
NSYCUF8KT10K NSYCUFX8KT10K - - - -
NSYCUF8KT10K NSYCUFX8KT10K - - - -
NSYCUF8KT10K NSYCUFX8KT10K - - - -
NSYCUF15K NSYCUFX15K - - - -
NSYCUF15K NSYCUFX15K - - - -
NSYCUF400R NSYCUFX400R - - - -
NSYCUF800R NSYCUFX800R - - NSYCURFT800R NSYCU760W230VR
NSYCUF1K2T2KR NSYCUFX1K2T2KR - - NSYCURFT1K2T2K NSYCU1050W230VR
NSYCUF1K2T2KR NSYCUFX1K2T2KR - - NSYCURFT1K2T2K NSYCUE1400W230R
NSYCU1460W230VR
NSYCU1650W230VR
NSYCUF1K2T2KR NSYCUFX1K2T2KR - - NSYCURFT1K2T2K NSYCUE1800W400R
NSYCU2000W400VR
NSYCUF1K2T2KR NSYCUFX1K2T2KR - - - -
NSYCUF3KT4KR NSYCUFX3KT4KR - - NSYCURFT3K NSYCU2450W400VR
NSYCU3100W400VR
NSYCUF3KT4KR NSYCUFX3KT4KR - - - -
NSYCUF1K1T2KS NSYCUFX1K1T2KS - NSYCUD1K1T1K5 - NSYCUB1100W230S
NSYCUF1K1T2KS NSYCUFX1K1T2KS - NSYCUD1K1T1K5 - NSYCUB1100W400S
NSYCUF1K1T2KS NSYCUFX1K1T2KS - NSYCUD1K1T1K5 - NSYCUB1500W230S
NSYCUF1K1T2KS NSYCUFX1K1T2KS - NSYCUD1K1T1K5 - NSYCUB1500W400S
NSYCUF1K1T2KS NSYCUFX1K1T2KS - NSYCUD1K1T1K5 - NSYCUB2200W230S
NSYCUF1K1T2KS NSYCUFX1K1T2KS - NSYCUD1K1T1K5 - NSYCUB2200W400S
NSYCUF2K5T3K2S NSYCUFX2K5T3K2S - NSYCUD1K1T1K5 - NSYCUB2700W230S
NSYCUF2K5T3K2S NSYCUFX2K5T3K2S - NSYCUD1K1T1K5 - NSYCUB2700W400S
NSYCUF2K5T3K2S NSYCUFX2K5T3K2S - NSYCUD1K1T1K5 - NSYCUB2700W230S
NSYCUF2K5T3K2S NSYCUFX2K5T3K2S - NSYCUD1K1T1K5 - NSYCUB2700W400S
451
ClimaSys CRS Thermal management system
Introduction
PB502437-32
They are extremely slim: 1.6 mm. As a result the usable
have been designed to resolve space in the cabinet has been optimised for installing
condensation problems in equipment. This can increase the usable space by up
to 30 %!
the most complex installations.
Is your enclosure short of space?
Does your mounting plate make
it impossible to install Heat and safety
The heat is distributed over the whole surface and does
a conventional resistor? not exceed 70°C. This temperature allows devices next
Do you not want to take out to the heater to be handled safely.
the equipment?
Discover the benefits of this
new offer and its numerous
mounting solutions. Multiple options for mounting
PB502046-22
No interference emissions
These resistors can be installed near electronic
equipment to guarantee optimum heat without the risk
of electromagnetic interference.
452
ClimaSys CRS Thermal management system
Characteristics and selection guide
PB502046-17
the mounting kit
PB502047-17
plate with mounting hardware
A: Mounting plate, ref. NSYMM●●●●
B
B: Mounting hardware included in the mounting
kit
A 3 - On DIN rail
B A: Mounting plate, ref. NSYMM●●●●
C B: Symmetrical DIN rail, ref. NSYSDR●●●●
C: Clip-on nuts, ref. AF1CG●, supplied with
PB502048-17
characteristics
PB501173-5
PB502042-4
PB501053-6
bb 6 plastic mountings
bb 4 Telequick nuts
bb 4 clip-on nuts
bb Mounting hardware
453
ClimaSys CR Thermal management system
Introduction
PB501027-20
PB501029-18
bb 2 versions: by natural convection and with fan.
for the correct operation of bb AC or DC power supply.
the electronic components bb 7 power levels, from 10 W to 550 W.
in the enclosure.
DB300452-43
PB501138-18
Innovating design
Covered with plastic to prevent direct contact with the
aluminium radiator.
PB501139-24
PB501026-36
bb Reduced dimensions.
bb Quick electric connection by terminal board.
bb No maintenance required.
bb Direct clipping onto a 35 mm DIN rail.
PB501027-36
PB501144-29
Safety
PB501026-14
PB501141-19
Certifications
DB123816-12
PB501143
bb CE marking.
bb Range compliant with UL and VDE.
454
ClimaSys CR Thermal management system
Introduction
PB501146-28
a PTC-type sensor
The resistance heaters for electrical and electronic
enclosures are equipped with PTC-type heating
devices (Positive Temperature Coefficient).
Thanks to these heaters:
bb The surface temperature stabilises at 75°C when
the ambient temperature is -5°C.
bb Power consumption is reduced.
Improved convection
The design of the profile of the resistance heaters
produces a "chimney" effect, leading to increased
natural convection and maintaining an even
temperature inside the enclosure.
Quick mounting
PB501147-111
Connection cables
PB501148-21
455
ClimaSys CR Thermal management system
Characteristics
Characteristics
Material
Conditions of use
456
ClimaSys CR Thermal management system
Characteristics
PB501026-39
PB501027-45
PB501144-31
Insulated PTC heater Insulated ventilated PTC heaters
bb Compact resistance heater preventing the formation of condensation or frost.
bb Designed to ensure good natural convection and high thermal efficiency.
Extruded aluminium body
bb The heaters must be installed with a thermal controller (see selection table on pages 460 and 461) to control the temperature or the humidity
inside the enclosure
bb The enclosure must be sealed to prevent the entry of air from the outside
bb An electrical protection device must be installed on the supply side of the unit
bb Operating position: vertical
bb Operating temperature: -40…+70°C; -10…+158°F
IP20
VDE and UL
Class ll (double insulated)
References
NSYCR10WU2C - -
75
NSYCR10WU1C - -
NSYCR20WU2C - -
NSYCR20WU1C - - 65 90
- NSYCR50WU2C -
- NSYCR50WU1C -
- NSYCR50WU3C -
- NSYCR100WU2C -
- NSYCR100WU1C -
- NSYCR100WU3C -
75
- NSYCR150WU2C -
- NSYCR150WU1C -
- - NSYCR170W230VVC
65 90
38 38 75 75
DB300543-61
DB300546-55
75
95
DB300544-53
75
32
65 90
NSYCR170W230VVC
98
98
75
95
1 2 1 2
32
NSYCR170W230VVC
75
95
32
NSYCR170W230VVC
457
ClimaSys CR Thermal management system
Characteristics, selection guide
PB501146-23
PB501025-21
PB501145-48
NSYCRS200W230V
Thermofan
PB501154-12
NSYCRP1W230VTVC
Characteristics Thermofan
bb Combination of a resistance heater and an axial motor to ensure uniform heating
of the enclosure.
bb Mounting by clip on a DIN rail.
bb Thermostat adjustable from 0…+60°C.
bb Visual operation indicator.
Power (W) Voltage (V) References
Terminal block
400/550 120 AC NSYCRP1W120VTVC
230 AC NSYCRP1W230VTVC
Mounting accessories
Description Supply References
Set of 5 studs NSYCRAF
PB501156-21
458
ClimaSys CC Thermal management system
Introduction
Thermal control
Mechanical thermostats Mechanical and electronic thermostats
PB501163-13
bb Large range of temperature control.
bb Small dimensions.
PB501162-19
PB501158-14
PB501160-14
bb Easily accessible terminals.
PB501170-12
Electronic thermostats
PB502624-75
New
PB502624-16
PB502623-17
PB502513-16
LED screen
Screen visible even in the dark.
New
New operational temperature range
-40°C ... +80°C.
bb On 35 mm DIN rail.
bb On Spacial upright.
PB501165-11
PB501166-19
bb On cross-rail.
PB501167-32
bb On mounting plate.
PB501168-14
bb UL,
bb CE.
459
ClimaSys CC Thermal management system
Characteristics, selection guide
Mechanical thermostats
PB501158-24
PB501160-24
PB501172-25
PB501162-25
Characteristics Thermostat Thermostat Thermostat Double Thermostat
With NC contact With NO contact With NO/NC contact
Thermostat with NC Contact:
bb to control the stopping of a resistance heater when the temperature exceeds the displayed value.
Thermostat with NO Contact:
bb to control the starting up of a fan when the temperature exceeds the displayed maximum value,
bb to control the temperature inside the enclosure by only starting up the fan when necessary, thus increasing the service life of the fan
and reducing the clogging of the filter.
Colour button Red Blue Black Red and blue
Ingress protection rating IP20 IP20 IP20 IP20
Sensor element Bimetal Bimetal Bimetal Bimetal
Contact NC, forced rupture NO, forced rupture Inverse,forced rupture NO / NC, forced rupture
Contact resistance < 10 mW < 10 mW < 10 mW < 10 mW
Service life > 100,000 cycles > 100,000 cycles > 100,000 cycles > 100,000 cycles
Switching capacity 250 V AC; 10 A (resistive load) 250 V AC; 10 A (resistive load) 250 V AC; 10 A (resistive load)
120 V AC; 15 A (resistive load) 120 V AC; 15 A (resistive load)
250 V AC/120 V AC 2 A (inductive load cos = 0.6) 250 V AC/120 V AC 2 A
30 W DC (inductive load cos = 0.6)
30 W DC
Max interrupting NA NA 250 V AC 4 A NA
capacity with direct (inductive load cos = 0.6)
current 30 W DC
Connection Two 2.5 mm2 terminals Two 2.5 mm2 terminals Four 2.5 mm4 terminals Six 2.5 mm6 terminals
Mounting By clip on 35 mm DIN rail By clip on 35 mm DIN rail By clip on 35 mm DIN rail Clip on 35 mm DIN rail
Enclosure UL 94 V-0 plastic, light grey UL 94 V-0 plastic, light grey UL 94 V-0 plastic, light grey UL 94 V-0 plastic, light grey
Dimensions 60 x 33 x 43 mm 60 x 33 x 43 mm 67 x 50 x 44 mm 60 x 33 x 43 mm
Weight 40 g 40 g 100 g 40 g
Mounting position Indifferent Indifferent Indifferent Indifferent
Operating temperature -20...+80°C (-4...+176°F) -20...+80°C (-4...+176°F) -20...+80°C (-4...+176°F) -20...+80°C (-4...+176°F)
Hysteresis 7°K 7°K 7°K 7°K
Temperature setting 0...+60°C 0...+60°C +5...+60°C 0...+60°C
range
Display °C °F °C °F °C °F °C °F
Max. command intensity 10 A 250 V (NO) 5 A (NC) 10 A (NO) 5 A (NC) 10 A
References
NSYCCOTHC NSYCCOTHCF NSYCCOTHO NSYCCOTHOF NSYCCOTHI NSYCCOTHIF NSYCCOTHD NSYCCOTHDF
N1 L1
DB300547-31
DB300547-31
DB300548-33
DB300549-32
11
Load Load Load A 12
2 2 V
> Load
> >
B 23
1 1
24
V
460
ClimaSys CC Thermal management system
Characteristics, selection guide
PB502623
PB502624
PB502513
Characteristics Electronic thermostat Electronic hygrotherm Electronic hygrostat
With LED screen With LED screen With LED screen
Electronic temperature controller. Electronic temperature and humidity Electronic humidity controller.
controller.
Ingress protection rating IP20 IP20 IP20
Certification UL / UR UL / UR UL / UR
Internal sensor element Temperature sensor Temperature sensor and humidity sensor Humidity sensor
Contact Free with zero potential Free with zero potential Free with zero potential
Connection 2 x 2.5 mm2 (input voltage) + 2 relays 2 x 2.5 mm2 (input voltage) + 2 relays 2 x 2.5 mm2 (input voltage) + 1 relay
(2 x 2.5 mm2 + 2 x 2.5 mm2) (2 x 2.5 mm2 + 2 x 2.5 mm2) (2 x 2.5 mm2)
Mounting 4 different methods: by DIN rail, 4 different methods: by DIN rail, 4 different methods: by DIN rail,
Spacial SF profile, on VDI cross-rail Spacial SF profile, on VDI cross-rail Spacial SF profile, on VDI cross-rail
or on mounting plate or on mounting plate or on mounting plate
Enclosure UL 94 V-0 plastic, light grey UL 94 V-0 plastic, light grey UL 94 V-0 plastic, light grey
Operating temperature -40°C…+80°C -40°C…+80°C -40°C…+80°C
Hysteresis Programmed 2°K 3% 3%
Temperature setting range -40°C…+80°C -40°C…+80°C -
Humidity setting range - 20 %…80 % 20 %…80 %
Display °C or °F °C or °F or % RH % RH
Max. command intensity 8 (5) A 230 V AC / 5 A 30 V DC 8 (5) A 230 V AC / 5 A 30 V DC 8 (5) A 230 V AC / 5 A 30 V DC
Voltage (type of current) References
9-30 V (AC/DC) NSYCCOTH30VID NSYCCOHYT30VID NSYCCOHY30VID
110-127 V (AC) NSYCCOTH120VID NSYCCOHYT120VID NSYCCOHY120VID
220-240 V (AC) NSYCCOTH230VID NSYCCOHYT230VID NSYCCOHY230VID
DB300550EN-80
DB300551EN-80
DB300552EN-80
Load2
Load1
Load2
Load1
Load2
Load2
Load1
Load2
Load1
Load2
N N N N N
N N N N
Load1
Load2
Load2
Load1
Load2
L L L L L L
L L L
Load (1) = fan/resistance Load (1) = fan/resistance Load (1) = fan/resistance
Load (2) = fan/resistance/alarm Load (2) = fan/resistance/alarm Load (2) = fan/resistance/alarm
461
ClimaSys CC Thermal management system
Accessories
Sensors
PB501181-34
PB501179-34
PB501180-34
Characteristics Smoke detector Vibration sensor Movement sensor
462
ClimaSys CC Thermal management system
Accessories
Sensors
PB501175-10
PB501182-34
PB501183-34
PB501183-34
PB501183-34
Extension cables Temperature sensor Humidity sensor Combined External temperature
temperature/humidity sensor (double
sensor insulation)
4 strand cable for sensors. bb Temperature value range: bb Humidity value range: Combines temperature and air bb Sensor operation or reading
bb Four lengths available: 0°… +60°. 10… 90 % relative humidity humidity sensor functions. range: -40°C…+150°C.
5, 10, 15 and 20 metres. bb Measurement accuracy: between 0° and +60°. bb Temperature value range: Thermostat installation tips:
bb Connections: RJ11. ± 1°C. bb Measurement accuracy: 0°… +60°. the thermostat should be
± 3 % relative humidity. bb Measurement accuracy: installed at the top of the
± 1°C. enclosure (the hottest place).
bb Humidity value range: See the various operating
10… 90 % relative humidity modes of each thermostat to
between 0° and +60°. choose the one that best
bb Measurement accuracy: meets your needs.
± 3 % relative humidity. Hygrostat installation tips:
the hygrostat should be
installed at the bottom of the
enclosure. 60% RH is the
optimum value in the
enclosure.
- - - - IP67
- - - - Several types of mountings
(on DIN rail, on Spacial SF
profile, on VDI cross-rail,
on mounting plate)
- With mountings With mountings With mountings -
- - - - NSYCCASTE
- NSY11951 NSY11952 NSY11953 -
NSY11959 - - - -
NSY11960 - - - -
NSY11961 - - - -
NSY11962 - - - -
463
ClimaSys CC Thermal management system
Accessories
Thermal control
Enclosures Monitor
PB501177
bb The enclosure monitor checks and protects all the equipment in the distribution,
network and server racks as well as their environment.
bb Ambient parameters and operating states can be measured using various sensors
and several inputs.
bb Signalling and display: on the unit, serial interface, Ethernet network.
bb Digital inputs and switching outputs enable permanent monitoring and
adapted actions.
Reference
NSY11950
Door contact
PB501178
Reference
NSY11955
464
ClimaSys Thermal management system
Thermal balance
Natural dissipation
DB300447-20
DB300453-18
Airing
Natural ventilation
The addition of fresh air from the outside through ventilation louvres improves the
dissipation of heat by natural convection. However, this solution can only be used
to dissipate small power levels and in environments with a small amount of dust.
Ventilating
DB300448-68
DB300453-18
Circulation
Air circulation inside the enclosure with the help of a fan makes it possible to
guarantee an even temperature, avoiding hot spots that can damage certain
components.
Forced ventilation
The fans are designed to evacuate a considerable amount of heat coming from
the components of the industrial control panels. The service life of the latter is
considerably extended, thus guaranteeing the long life and correct operation
of the installation.
The fans can only be used if the ambient temperature is at least 5°C lower than
the desired temperature inside the enclosure.
They offer an efficient solution, one that is easy to implement and maintain, which
is also inexpensive, to the problem of temperature increases in the industrial control
panels. Thanks to their standard IP54 (IP55 with accessories) they are suitable for
use in industrial and tertiary sectors.
Heating
DB300452-68
DB300453-18
Resistance heaters
Resistance heaters can be used for two reasons:
bb To reheat the industrial control panel when the ambient temperature is too low
for the correct operation of the components.
bb To prevent the formation of condensation.
The second phenomenon can cause short-circuits, premature oxidation of the
contacts, corrosion of metal parts and, in particular, of the enclosure, a considerable
reduction in the service life of the electrical and electronic components.
Condensation occurs when the temperature suddenly drops below the dew point
temperature. To avoid this, it is simply necessary to maintain the temperature inside
the enclosure at a few degrees above the ambient temperature of the environment.
Thanks to their design, the heaters encourage natural convection and guarantee
quick and even heating within the enclosure.
465
ClimaSys Thermal management system
Thermal balance
Cooling
Air-air exchangers
DB300449-68
DB300453-18
Air-air exchangers are devices that combine efficiency and simplicity. The hot air
flows of the enclosure and the cold of the surrounding environment, created by two
fans, circulate on either side of hermetic separation walls, preventing the penetration
of dust or moisture in the enclosure. The hot air from the switchboard reheats these
walls, which in turn are cooled by the fresh air from outside. The transfer always
takes place from the hotter side to the cooler side. This is why these devices can
only be used if the ambient temperature is at least 5°C lower than the desired
temperature inside the enclosure.
The aluminium exchange cassette forms the core of the system. This element can
be cleaned easily by simply removing it. In addition, the permanent operation of
the internal fan prevents the appearance of hot spots in the industrial control panel.
The temperature regulation system integrated in the unit turns the external circuit
fan on and off.
Air-water exchangers
DB300453-18
DB300555-20
Cooling units
DB300451-76
DB300453-18
Cooling units can be used in the harshest environments, where the temperature
can reach 55°C. These devices are especially recommended when the desired
temperature inside the enclosure must be lower than the ambient temperature
or when a large amount of heat needs to be evacuated. As in the case of the
exchangers, they do not affect the IP of the switchboard.
The filter, placed at the inlet of the external air circuit, allows it to operate even when
the ambient air is charged with dust or oil particles. Easily replaceable and quite
inexpensive, this device guarantees the efficiency of the device throughout its
service life. These devices control the temperature inside the enclosure and include
an alarm function for signalling operational anomalies.
DB300453-13
466
ClimaSys Thermal management system
Thermal balance
467
ClimaSys Thermal management system
Thermal balance
T °C
Tidmax < Timax
∆ Tmin = (Tidmax - Temax)
bb ∆ Tmin = +5°C: Ventilation
a
Tidmax bb ∆ Tmin = +10°C: Exchanger air-air
bb ∆ Tmin = -5°C: Cooling unit
Ti bb Not depending on (∆ Tmin): Exchanger air-water
Tidmin b:
b
Tidmin > Timin: Heaters
t (h)
If Tidmin < Tfimin If Tidmin > Tfimin If Tidmax < Tfimax If Tidmax > Tfimax
No need for a thermal system; Need for a thermal system: Need for a thermal system: No need for a thermal system;
a circulation fan may be used resistance heater ventilation, fan, exchanger, a circulation fan may be used
to even out the temperature. 1- Permanent operation of the cooling unit. to even out the temperature.
switchboard
Psyst = K x S (Tidmin - Temin) - Pd Psyst = Pd - K x S (Tidmax - Temax)
Psyst = 800 - 5.5 x 4.13 x
2- Discontinuous operation (40 - 35)
Psyst = K x S (Tidmin - Temin) ~ 690 W
468
ClimaSys Thermal management system
Software
ProClima
New ProClima software
PB500011-56
bb Software package for calculating and selecting the thermal accessories required
for enclosures containing electrical and electronic equipment.
bb Performs the calculations as well as the corrected surfaces, according to
the dimensions of the enclosure and its position in relation to the walls.
bb Available for download on our homepage.
Data entry
The following steps must be followed to conduct this study:
2 - Enter the internal and external temperature data for the enclosure
PB501185
(compulsory).
3 - Enter the electrical data for the installation (voltage, rating, etc.) (compulsory).
PB501186
enclosure (compulsory).
If this value is not known, the software can calculate it:
bb Based on the electrical or electronic switchgear that make up the switchboard
(type and number),
bb Based on a temperature reading.
469
ClimaSys Thermal management system
Software
ProClima
Results
Summary of the heat balance
The software offers to print the project summary containing the calculation values,
the results obtained and the thermal accessories recommended for maintaining
the internal temperature of the enclosure in the specified conditions.
In addition, the summary specifies the power, characteristics and reference of
the device, as well as any related accessories.
470
ClimaSys Thermal management system
Example of calculation and selection
Data
bb Enclosure data
vv Height: 2000 mm
vv Width: 800 mm
vv Depth: 500 mm
bb Location: placed on the wall
bb Material: painted sheet-steel enclosure
bb Thermal power dissipated by the operational components Pd: 950 W
bb Information on temperature and the environment:
Maximum desired temperature inside the enclosure Temax: 25°C
Minimum desired temperature inside the enclosure Temin: 25°C
(1) Pd = Thermal power dissipated by the operational Maximum temperature dissipated in the enclosure Temax: 35°C
components Minimum temperature dissipated in the enclosure Temin: 25°C
S = 1.4 x W x (H + D) + 1.8 x D x H = 4.6 m2. bb Environment: low pollution and low dust level
According to standard IEC 890 Selection and calculation
K = Constant defined by the material used to
The desired maximum temperature inside (Tsmax) the enclosure is 10°C
manufacture the enclosure
K = 5.5 W/m2 x °C for a solid sheet-steel enclosure higher than the maximum value expected for the outside (Timax).
K = 3.5 W/m2 x °C for a polyester enclosure It is possible to cool the enclosure using the filtered ventilation systems.
K = 3.7 W/m2 x °C for a stainless-steel enclosure
Calculation of the required fan (1)
f = Coefficient relating to the height above
sea level (value) Usage formulas:
0 to 100 m: f = 3.1 Psyst = Pd - K x S x (Tsmax - Temax)
100 to 250 m: f = 3.2 Flow = f x Psyst / (Tsmax - Temax)
250 to 500 m: f = 3.3 In order to make the calculation, it is necessary to know the height above sea
500 to 750 m: f = 3.4
level of the installation location:
750 to 1000 m: f = 3.5
… Height above sea level: 800 m
Our example
Psyst = 950 - 5.5 x 4.6 x (35 - 25) = 697 W
Flow rate = 3.5 x 697 / (35 - 25) = 244 m3/h
471
ClimaSys Thermal management system
Help table to calculate corrected surfaces
Installation mode
1 Accessible from every side
2 Placed against a wall
3 On the end when suited
4 On the end when suited, placed against a wall
5 In the middle when suited
6 In the middle when suited, placed against a wall
In the middle when suited, placed against a wall with
7
the top covered
The surfaces are given in m2.
472
ClimaSys Thermal management system
Help table to calculate corrected surfaces
473
ClimaSys Thermal management system
Help table to calculate corrected surfaces
Installation mode
1 Accessible from every side
2 Placed against a wall
3 On the end when suited
4 On the end when suited, placed against a wall
5 In the middle when suited
6 In the middle when suited, placed against a wall
In the middle when suited, placed against a wall with
7
the top covered
The surfaces are given in m2.
474
ClimaSys Thermal management system
Help table to calculate corrected surfaces
475
Technical guides
and spare parts
476
Universal Enclosures Technical guides and spare parts
Contents
477
Technical annexes Enclosure certifications
SFHD
SFP
SM
S3D (1)
S3HD
SBM
SFX
SMX
S3X (1)
Thalassa
PLA
PLAT
PLAZ
PLATZ
PLD
PHD
PLM (1)
PLS (3)
TBS/TBP (2)
ClimaSys
CV
CU
CE
CR
CC
(1) ATEX certifications relate to an adapted part of the range. These ranges are distinguished by their EX endings.
(2) Only TBP.
(3) Transparent cover in process.
PB500053
PB500052
PB500048
PB500048
PB500050
PB500055
DB300966
PB500051
PB500054
478
Technical annexes International enclosure standard
Standards IEC 62208*
General rules.
Application
For empty enclosures before adding the user's switchgear, in the condition as
supplied by the manufacturer.
Field of application
Demands for testing the enclosures to be used as part of the switchgear assemblies
for voltages of less than 1000 V alternating current and 1500 V direct current.
* European standard EN 62208 is identical to IEC 62208. European countries publish this
standard according to the body in each country (for example BS EN 62208 in the UK).
479
Technical annexes Selection of enclosures
Name Range IP40 IP41 IP42 IP43 IP44 IP54 IP55 IP65 IP66
Metal industrial boxes Spacial SBM (4) (4)
Metal derivation boxes Spacial SDB
Steel universal wall-mounting enclosures Spacial S3D (1)
Steel modular distribution wall-mounting Spacial S3DM
enclosures
Terminal wall-mounting enclosures Spacial S3DB
EMC steel wall-mounting enclosures Spacial S3HF
HMI steel wall-mounting enclosures Spacial S3CM
ATEX steel wall-mounting enclosures Spacial S3DEX
Stainless-steel wall-mounting enclosures Spacial S3X
ATEX stainless-steel wall-mounting Spacial S3XEX
enclosures
Steel floor-standing enclosures Spacial SM
Steel suitable enclosures Spacial SF
Stainless-steel floor-standing enclosures Spacial SMX
Stainless-steel suitable enclosures Spacial SFX
Steel control desks Spacial SD
Stainless-steel control desks Spacial SDX
Thermoplastic industrial boxes Thalassa TBS-TBP
Polyester modular boxes Thalassa PLS
Polyester wall-mounting enclosures Thalassa PLM
ATEX polyester wall-mounting enclosures Thalassa PLMEX
Polyester floor-standing enclosures Thalassa PLA (2)
Thalassa PLD (3)
solutions bb Steel enclosures are particularly well suited to indoor use in industrial
environments.
bb Stainless-steel enclosures are particularly well suited to corrosive environments
or areas where specific hygiene demands are applicable.
Steel bb Polyester enclosures are particularly well suited to severe corrosive atmospheres,
indoors or outdoors.
Enclosures made from insulating materials guarantee total insulation, reducing
Stainless-steel electric hazards for persons.
The main characteristics of the plastic materials of our enclosures and their chemical
strength are given on page 486.
Plastic & Polyester Further help for making the selection is given by the NEMA or UL classification
of the enclosure, see page 483.
480
Technical annexes Degrees of protection provided
by enclosures
IP IK
bb The degrees of protection provided by the
enclosures are defined by standards IEC 60529 First numeral Second numeral Mechanical protection
Protection against Protection against liquids
(IP) and IEC 62262 (IK). solid bodies
bb Degrees of protection are indicated by the
letters IP followed by two characteristic numerals. 0 0 0
The numerals show the degree of protection
offered by the enclosure against access to
dangerous parts, the penetration of of solid No protection No protection No protection
bodies (1st numeral), and against the penetration
1 1 1
200
g
of liquids (2nd numeral).
bb The protection against external mechanical 7.5 cm
impact is indicated by the letters IK followed
Impact energy: 0.150 Joules
by a characteristic group numeral. Protected against solid Protected against
bodies larger than 50 mm vertically falling water 200
Note: Many EN European standards are harmonised (e.g.: incidental contact droplets (condensation) 2 g
3
200
g
3 3 4
200
g
25 cm
Protected against solid Protected against Impact energy: 0.500 Joules
bodies larger than 2.5 mm rainwater at up to 60º
(tools, wires) from vertical
5
200
g
4 4
35 cm
5 5 20 cm
8 1,7
kg
10 5k
g
Protected against
prolonged effects of
immersion under pressure
40 cm
481
Technical annexes Classification of electrical
equipment enclosures
according to NEMA and UL
NEMA and UL are standardisation bodies, commonly recognised in North America,
which have issued classifications of enclosures according to the protection offered
in various environments.
These classifications are similar.
The 1st table below summarises this classification, which does not include potentially
explosive areas. The detailed recommendations of this classification are given on
the next page.
The 2nd table indicates the classification of our enclosures.
These classifications appear in our UL certifications (see Certification technical
annex on page 478).
Certification according to the UL classification guarantees the corresponding NEMA
classification by equivalence.
482
Technical annexes Classification of electrical
equipment enclosures
according to NEMA and UL
The enclosures must protect the equipment against environmental conditions and
PB500063-55
protect the personnel against the risk of incidental contact with the equipment.
The following classifications (Type) are required according to the required uses
and prescriptions:
outdoor use incidental contact with the internal equipment and protects
said equipment against dirt, rain, sleet, snow, windblown dust,
splashes and hose-directed water and resists the formation
of frost on the outside.
4x Indoor and The enclosure provides protection for the personnel against
outdoor use incidental contact with the internal equipment and protects
said equipment against dirt, rain, sleet, snow, windblown dust,
splashes, hose-directed water and resists corrosion and the
formation of ice on the outside.
5 Indoor use The enclosure provides protection for the personnel against
incidental contact with the internal equipment and protects
said equipment against dirt, settling airborne dust, lint, fibres,
flyings, drips and gentle splashes of non-corrosive liquids.
6 Indoor and The enclosure provides protection for the personnel against
outdoor use incidental contact with the internal equipment and protects
said equipment against dirt, rain, sleet, snow, hose-directed
of water, the entry of water during occasional temporary
submersion to a limited depth and resists the formation
of ice on the outside.
6P Indoor and The enclosure provides protection for the personnel against
outdoor use incidental contact with the internal equipment and protects
said equipment against dirt, rain, sleet, snow, hose-directed
water, the entry of water during prolonged submersion to a
limited depth and resists corrosion and the formation of ice
on the outside.
12 Indoor use The enclosure provides protection for the personnel against
(without knockouts) incidental contact with the internal equipment and protects
said equipment against dirt, dust, fluff, fibres, particles in
suspension, drips and gentle splashes of non-corrosive
liquids as well as gentle splashes or leaks of oil and
non-corrosive coolants.
12K Indoor use The enclosure provides protection for the personnel against
(enclosures with incidental contact with the internal equipment and protects
pre-routing) said equipment against dirt, dust, lint, fibres flyings drips and
gentle splashes of non-corrosive liquids as well as gentle
splashes or leaks of oil and non-corrosive coolants.
13 Indoor use The enclosure provides protection for the personnel against
incidental contact with the internal equipment and protects
said equipment against dirt, dust, lint, fibres flyings and the
spraying, splashing, and seepage leaks of water, oil or
non-corrosive coolants.
Note: The above recommendations aim to explain the NEMA and UL classifications,
but are not the official texts of NEMA or UL.
The exact definitions provided by the Organisations are those of standards NEMA 250
and UL 50E.
483
Technical annexes Polyester base coating
properties
Product type
PB500058-56
Thermosetting polyester resins based powder coating modified by epoxy resins and
designed for decoration and to prevent corrosion.
The performance of this coating is superior to conventional epoxy powders in terms
of: colour stability, temperature resistance and weather resistance.
Grey RAL 7035; appearance: structured.
Mechanical properties
Test conditions: steel samples with a thickness of 10/10e mm.
Degreasing using biodegradable surface-active agents.
Film thickness: 60 microns.
Chemical properties
Tests conducted at ambient temperature on phosphated samples covered
with a 150 to 200 micron film:
Film intact.
Film attacked (blistering, yellowing, loss of gloss).
Number of months 2 4 6 8 10 12
Acid Acetic 20 %
Sulphuric 30 %
Nitric 30 %
Phosphoric 30 %
Hydrochloric 30 %
Lactic 10 %
Citric 10 %
Base Soda 10 %
Ammonia 10 %
Water Distilled water
Sea water
Tap water
Diluted chloride
bleach
Solvents Petrol
Higher alcohols
Aliphatics
Aromatics
Ketones-esters
Tri-perchlorethylene
Physical properties
Temperature resistance: -40°C and 100 hours at +150°C (colour: white).
Gloss retention: good.
Resistance to corrosion
Compliance with standard IEC 62208 for outdoor installations: 288 h of humid heat
and 336 h of salt mist.
484
Technical annexes Polyester base coating
properties
Nuclear decontamination
Applicable to colours RAL 7035 and AFNOR A550.
Standard NFT 30901. Percentage of decontamination for contamination by fission
products. Please consult us for further details.
Accelerated aging
Standard IEC 62208: 500 h UV according to ISO 4892 (method A) (adherence of the
coating with minimum retention of 50% on the grid according to ISO 2409).
Fire behaviour
Class M1 (self-extinguishing material).
Class M0 (for coating on a metal base).
Manufacturing process
Degreasing
Rinsing
Chemical conversion
Drying
Coating
Polymerisation
Mounting
485
Technical annexes Properties of the plastic materials
Mechanical, electrical, physical
and fire-resistance properties
486
Technical annexes Properties of the plastic materials
Resistance to chemical agents
Resistance to ABS Polycar- PVC Bayblend® Polyester Altuglas Polypro- Poly- Polyamide Polyamide SBS
bonate pylene styrene 6 12
Acetone – – – – – O 100 + – 100 + + +
Hydrochloric acid 15 + 10 + 30 + 20 + 30 + sat + 10 + O 10 – 10 + 10 +
Citric acid 10 + sat + 10 + 100 + sat + sat + + 10 O + 10 +
Lactic acid 80 + 10 + 90 + 10 – 100 + 20 + 90 + O 50 O + sat +
90 – +
Nitric acid 30 + 10 + 50 + 10 + 20 + 10 + 25/ O 2 O – 50 +
100 – + 100 – 50 10 –
Phosphoric acid 85 + 100 + sat + + 100 + 10 + sat + O 2 O 50 + +
95 – 10 –
Sulphuric acid 50 + 50 + 96 + 30 + 70 + 30 + 96 + O 3 – 10 + 96 +
100 –
Alcohol O 96 + 96 + – 50 O 50 O 96 + + 96 O 96 + +
Pure aniline O – 100 – – O – 100 + 100 O 100 O
Benzene + 100 – – + – O 100 O 100 + + –
Liquid bromine 100 – – – 100 – 100 – –
Liquid chlorine – 100 – – sat + – 100 – 100 O – 50 +
Sea water + 100 + 100 + + 100 + 100 + – 100 + 100 + sat +
Petrol + 100 + 100 O – 100 + 100 O – – 100 + + –
Ether – 100 O 100 – – 100 O + 100 + 100 + –
Hexane O + O O – 100 + 100 + 100 + –
Oil and greases + 100 + 100 + O 100 + 100 O 100 + – + 100 + –
Aromatic O – – – – + – – – + –
hydrocarbon
Fuel oil O 100 O 100 + – 100 + 100 – 100 + 100 + 100 + –
Naphthalene 100 O – 100 + 100 – 100 + 100 + 100 +
Nitrobenzene – – 100 – – – 100 O – O –
Phenol – – sat O – 20 O – sat + – – 10 O
Mineral salts + + + + + + + +
Iodine solution O – + – +
Toluene – – 100 – – + O 100 O – 100 + 100 + –
Trichloroethylene – – 100 – – – – 100 O – 100 – 100 O –
Urea sat + sat + + sat + 10 + sat + sat O
For other chemical agents, please contact us.
All this information is taken from the best sources and provided for information purposes only, with no commitment on our behalf.
487
Technical annexes Description of the marking
label affixed to ATEX certified
wall-mounting enclosures
Spacial S3XEX
DB300850
Ref: SPACIAL S3XEX 1
AA-YYYWW-XXXXXXXXX
IP66 7
2 0163 3 Ex e IIC Gb
II 2 GD
4 Ex t IIIC Db
5 -25°C ≤ Ta ≤ 60°C
Thalassa PLMEX
DB300851
IP66 7
2 0163 3
II 2 GD Ex e IIC Gb
4 Ex t IIIC Db
5 -25°C ≤ Ta ≤ 60°C
Spacial S3DEX
DB300871
Réf: NSYS3DEX 1
0942
12345678
6 LCIE 02 ATEX 0037 U Made in France
2 3 4 0081 II 2 GD EX e IIC Gb Ex tb IIIC Db
1 Product range
488
Technical annexes How to select your enclosures
& accessories?
Environment
In what type of environment will you be installing your products? bb Indoor industrial environments, use steel.
bb Indoor corrosive environments or with specific hygienic demands, use stainless-steel.
bb Severe corrosive environments, indoor or outdoor, use polyester enclosures.
bb Always think about the thermal issue. We have the right solution.
Is a canopy required? A canopy is mandatory when liquid can fall on an enclosure.
Our polyester enclosures (PLM and PLAT) are pre-equipped.
Technical requirements
Are tightness and resistance to external mechanical impact Each enclosure specifies its:
needed in your case? bb Tightness: IP.
bb Resistance to external mechanical impact: IK.
Have you any size-related installation constraints? Check the dimensions of the enclosure:
Height (H) x Width (W) x Depth (D) in mm.
What colours are available? RAL 7035 is our standard on steel enclosures.
Other colours are available on demand.
How do you install your enclosures? Installation possible:
bb On a wall.
bb On the floor.
bb On a post.
Available accessories:
bb Mounting brackets.
bb Plinths.
bb Post mounting devices.
bb Reinforcement for heavy load.
Door
Need to see inside the enclosure? Choice of:
bb Glazed doors.
bb Acrylic windows.
bb Control protection frames.
What type of lock do you want? The type of lock is to be specified:
bb Inserts.
bb Keys.
bb Padlocks.
Do you need an earth connection? Electrical continuity by earthing braids or leads available as accessories.
How will you mount your raceways to the door? They can be fixed thanks to:
On the uprights? bb Cable-duct supports.
On the rails? bb Door cross-rails.
bb Cable ties.
Are doors opened for maintenance? You may need:
bb Door stops.
bb Door switches.
Body or frame
Where do the cables enter the enclosure from? A large variety of cable entries available.
What functions should this cable-entry provide? Our cable glands or membranes provide:
bb Thightness.
bb Cable supports.
Mounting accessories
How will the equipment be installed inside your enclosure? Several mounting plates according to your application:
bb Plain.
bb Micro-perforated (Telequick System).
bb Perforated (Telequick System).
bb Modular.
bb 19”.
Do you require cable accessories? bb Cable ducts.
bb Cable cross rails.
bb Cable supports…
… are available, see our catalogue for more details.
Thermal
Do you need to cool? bb Ventilation louvers.
Heat? bb Ventilation grilles.
Dry? bb Forced ventilations.
bb Resistance heaters.
bb Thermostats.
bb Calculations with ClimaSys software.
Refer to our Thermal Control section.
Logistics and handling
How do you handle the enclosures? Thanks to eyebolts and lifting brackets.
489
Spare parts
Selection table
To find out more about our spare parts offer, visit our
website at www.schneider-electric.com
490
Spare parts
Selection table
S3DM
Description References Description References
Doors Locking accessories
Glazed door 400 x 300 NSYDS3D43T Set of 10 linkage guides NSYS3DLG
Glazed door 500 x 400 NSYDS3D54T Standard key DB3 NSYAEDLS3DKDB3
Glazed door 600 x 400 NSYDS3D64T 3 point lock linkage H 600 mm NSYBTAS3D60
Glazed door 600 x 600 NSYDS3D66T 3 point lock linkage H 700 mm NSYBTAS3D70
Glazed door 700 x 500 NSYDS3D75T 3 point lock linkage H 800 mm NSYBTAS3D80
Glazed door 800 x 600 NSYDS3D86T 3 point lock linkage H 1000 mm NSYBTAS3D100
Glazed door 1000 x 600 NSYDS3D106T Panels
Glazed door 1000 x 800 NSYDS3D108T 50 caps for holes of hinges WM NSYSWMCH
Earthing accessories Set of 50 back plugs WM NSYSWMBP
Set of 500 earthing labels NSYSWMEL
Mounting hardware
100 screws cable gland plate NSYS3DCGSB
Standard screw bag cable gland plate NSYS3DCGPSTDSB
S3DC
Description References Description References
Doors Earthing accessories
Plain door 300 x 200 NSYDS3DC32 Set of 500 earthing labels NSYSWMEL
Plain door 300 x 300 NSYDS3DC33 Locking accessories
Plain door 400 x 300 NSYDS3DC43 Set of 10 linkage guides NSYS3DLG
Plain door 400 x 400 NSYDS3DC44 Standard lock enclosures NSYAEDLS3DC
Plain door 500 x 400 NSYDS3DC54 3 point lock linkage H 600 mm NSYBTAS3D60
Plain door 500 x 500 NSYDS3DC55 3 point lock linkage H 700 mm NSYBTAS3D70
Plain door 600 x 400 NSYDS3DC64 3 point lock linkage H 800 mm NSYBTAS3D80
Plain door 600 x 600 NSYDS3DC66 3 point lock linkage H 1000 mm NSYBTAS3D100
Plain door 700 x 500 NSYDS3DC75 3 point lock linkage H 1200 mm NSYBTAS3D120
Plain door 800 x 600 NSYDS3DC86 Panels
Plain door 800 x 800 NSYDS3DC88
50 caps for holes of hinges WM NSYSWMCH
Plain door 1000 x 600 NSYDS3DC106
Set of 50 back plugs WM NSYSWMBP
Plain door 1000 x 800 NSYDS3DC108
Plain door 1000 x 1000 NSYDS3DC1010
Plain door 1200 x 800 NSYDS3DC128
Plain door 1200 x 1000 NSYDS3DC1210
S3DCD
Description References Description References
Doors Locking accessories
Plain door 500 x 500 NSYDS3DCD55 Standard lock enclosures NSYAEDLS3DC
Plain door 600 x 600 NSYDS3DCD66 3 point lock linkage H 700 mm NSYBTAS3D70
Plain door 700 x 500 NSYDS3DCD75 3 point lock linkage H 800 mm NSYBTAS3D80
Plain door 800 x 600 NSYDS3DCD86 3 point lock linkage H 1000 mm NSYBTAS3D100
Plain door 1000 x 600 NSYDS3DCD106 3 point lock linkage H 1200 mm NSYBTAS3D120
Plain door 1000 x 800 NSYDS3DCD108 Panels
Plain door 1000 x 1000 NSYDS3DCD1010 50 caps for holes of hinges WM NSYSWMCH
Plain door 1200 x 1000 NSYDS3DCD1210 Set of 50 back plugs WM NSYSWMBP
S3DB
Description References Description References
Doors Earthing accessories
Plain door 250 x 300 NSYDS3DB2530 Set of 500 earthing labels NSYSWMEL
Plain door 250 x 400 NSYDS3DB2540 Locking accessories
Plain door 250 x 500 NSYDS3DB2550 Standard key DB3 NSYAEDLS3DKDB3
Plain door 300 x 300 NSYDS3DB33 Panels
Plain door 300 x 400 NSYDS3DB34
50 caps for holes of hinges WM NSYSWMCH
Plain door 300 x 500 NSYDS3DB35
Set of 50 back plugs WM NSYSWMBP
Plain door 300 x 600 NSYDS3DB36
Plain door 400 x 300 NSYDS3DB43
Plain door 400 x 800 NSYDS3DB48
Plain door 500 x 400 NSYDS3DB54
Plain door 600 x 400 NSYDS3DB64
491
Spare parts
Selection table
CRN
Description References Description References
Doors Plain door H 400 x W 300 NSYDCRN43
Glazed door H 300 x W 250 NSYDCRN3025T Plain door H 400 x W 400 NSYDCRN44
Glazed door H 300 x W 300 NSYDCRN33T Plain door H 400 x W 600 NSYDCRN46
Glazed door H 300 x W 400 NSYDCRN34T Plain door H 500 x W 400 NSYDCRN54
Glazed door H 400 x W 300 NSYDCRN43T Plain door H 500 x W 500 NSYDCRN55
Glazed door H 400 x W 400 NSYDCRN44T Plain door H 600 x W 400 NSYDCRN64
Glazed door H 400 x W 600 NSYDCRN46T Plain door H 600 x W 500 NSYDCRN65
Glazed door H 500 x W 400 NSYDCRN54T Plain door H 600 x W 600 NSYDCRN66
Glazed door H 500 x W 500 NSYDCRN55T Plain door H 600 x W 800 NSYDCRN68
Glazed door H 600 x W 400 NSYDCRN64T Plain door H 700 x W 500 NSYDCRN75
Glazed door H 600 x W 500 NSYDCRN65T Plain door H 800 x W 600 NSYDCRN86
Glazed door H 600 x W 600 NSYDCRN66T Plain door H 800 x W 800 NSYDCRN88
Glazed door H 600 x W 800 NSYDCRN68T Plain door H 1000 x W 600 NSYDCRN106
Glazed door H 700 x W 500 NSYDCRN75T Plain door H 1000 x W 800 NSYDCRN108
Glazed door H 800 x W 600 NSYDCRN86T Door accessories
Glazed door H 800 x W 800 NSYDCRN88T Standard Spacial hinge NSYBICRN
Glazed door H 1000 x W 600 NSYDCRN106T Earthing accessories
Glazed door H 1000 x W 800 NSYDCRN108T Set of 500 earthing labels NSYSWMEL
Plain door H 200 x W 200 NSYDCRN22 Locking accessories
Plain door H 200 x W 300 NSYDCRN23
TCRE1 Lock NSYTCRE1
Plain door H 250 x W 200 NSYDCRN2520
TCRE12 Lock NSYTCRE12
Plain door H 300 x W 250 NSYDCRN3025
CRN Standard Lock, 3 mm DB NSYCDB3
Plain door H 300 x W 300 NSYDCRN33
CRN Standard Key, 3 mm DB Lock NSYDBP
Plain door H 300 x W 400 NSYDCRN34
Panels
Plain door H 300 x W 450 NSYDCRN3045
Set of 50 back plugs WM NSYSWMBP
PB500373-30
CRNG
Description References Description References
Earthing accessories Panels
Set of 500 earthing labels NSYSWMEL 50 caps for holes of hinges WM NSYSWMCH
Mounting hardware Set of 50 back plugs WM NSYSWMBP
100 screws cable gland plate NSYS3DCGSB
Standard screw bag cable gland plate NSYS3DCGPSTDSB
492
Spare parts
Selection table
SM
PB502401-26
493
Spare parts
Selection table
494
Spare parts
Selection table
S3X (wall-mounting)
Description References Description References
Doors Plain door 316L 400 x 600 mm NSYDS3X46H
Left door 304L 1000 x 1000 mm NSYDS3X1010L Plain door 304L 500 x 400 mm NSYDS3X54
Left door 316L 1000 x 1000 mm NSYDS3X1010LH Plain door 316L 500 x 400 mm NSYDS3X54H
Right door 304L 1000 x 1000 mm NSYDS3X1010R Plain door 304L 600 x 400 mm NSYDS3X64
Right door 316L 1000 x 1000 mm NSYDS3X1010RH Plain door 316L 600 x 400 mm NSYDS3X64H
Plain door 304L 1000 x 800 mm NSYDS3X108 Plain door 304L 600 x 600 mm NSYDS3X66
Plain door 316L 1000 x 800 mm NSYDS3X108H Plain door 316L 600 x 600 mm NSYDS3X66H
Left door 304L 1200 x 1000 mm NSYDS3X1210L Plain door 304L 700 x 500 mm NSYDS3X75
Left door 316L 1200 x 1000 mm NSYDS3X1210LH Plain door 316L 700 x 500 mm NSYDS3X75H
Right door 304L 1200 x 1000 mm NSYDS3X1210R Plain door 304L 800 x 600 mm NSYDS3X86
Right door 316L 1200 x 1000 mm NSYDS3X1210RH Plain door 316L 800 x 600 mm NSYDS3X86H
Plain door 304L 1200 x 800 mm NSYDS3X128 Plain door 304L 800 x 800 mm NSYDS3X88
Plain door 316L 1200 x 800 mm NSYDS3X128H Plain door 316L 800 x 800 mm NSYDS3X88H
Plain door 304L 300 x 200 mm NSYDS3X32 Transp. door 304L 1000 x 800 mm NSYDS3X108T
Plain door 304L 300 x 250 mm NSYDS3X325 Transp. door 304L 400 x 300 mm NSYDS3X43T
Plain door 316L 300 x 250 mm NSYDS3X325H Transp. door 304L 500 x 400 mm NSYDS3X54T
Plain door 316L300 x 200 mm NSYDS3X32H Transp. door 304L 600 x 400 mm NSYDS3X64T
Plain door 304L 300 x 300 mm NSYDS3X33 Transp. door 304L 700 x 500 mm NSYDS3X75T
Plain door 316L 300 x 300 mm NSYDS3X33H Transp. door 304L 800 x 600 mm NSYDS3X86T
Plain door 304L 400 x 300 mm NSYDS3X43 Door accessories
Plain door 316L 400 x 300 mm NSYDS3X43H Set of 2 hinges NSYHS3X
Plain door 304L 400 x 400 mm NSYDS3X44 Locking accessories
Plain door 316L 400 x 400 mm NSYDS3X44H Locking system 1000 mm NSYLSS3X10
Plain door 304L 400 x 600 mm NSYDS3X46 Locking system 1200 mm NSYLSS3X12
SMX (floor-standing)
PB500138-45
495
Spare parts
Selection table
Insulating materials
PLA (floor-standing)
PB501347SE-29
496
Spare parts
Selection table
Insulating materials
PB501325SE-32
PLM (wall-mounting)
Description References Description References
Doors Glazed door without locking NSYDPLM86T
for PLM86T
Door without locking for PLM32 NSYDPLM32
Glazed door without locking NSYDPLM108T
Door without locking for PLM3025 NSYDPLM3025
for PLM108T
Transp. door without locking NSYDPLM32T
for PLM32T Door accessories
Glazed door without locking NSYDPLM3025T Door hinge for NSYPLM32 NSYAEDHPLM32
for PLM3025T Door hinge for NSYPLM3025 NSYAEDHPLM3025
Door without locking for PLM43 NSYDPLM43 Door hinge for NSYPLM43 to 86 NSYAEDHPLM
Door without locking for PLM54 NSYDPLM54 Door hinge for NSYPLM108 NSYAEDHPLM108
Door without locking for PLM64 NSYDPLM64 Mounting hardware
Door without locking for PLM75 NSYDPLM75 Acc. bag NSYPLM32 NSYASPLM32
Door without locking for PLM86 NSYDPLM86 Acc. bag NSYPLM43 to 86 NSYASPLM
Door without locking for PLM108 NSYDPLM108 Locking accessories
Glazed door without locking NSYDPLM43T
Locking and rods for NSYPLM108 NSYVPLM108
for PLM43T
Glazed door without locking NSYDPLM54T
for PLM54T
Glazed door without locking NSYDPLM64T
for PLM64T
Glazed door without locking NSYDPLM75T
for PLM75T
497
Spare parts
Selection table
SDX
Description References Description References
Cable gland plates Locking accessories
Cable gland pl. SDX85/SMX85/SFX86 NSYCEX7 Locking system NSYLSSDX
Cable gland plate SDX105/SFX106 NSYCEX13 Panels
Cable gland plate SDX125/SMX125 NSYCEX16 Rear panel 1000 mm NSYBPSDX10
Cable gland plate SDX65/SFX126 NSYCEX3 Rear panel 1200 mm NSYBPSDX12
Doors Rear panel 600 mm NSYBPSDX6
Frontal door 600 mm NSYDSDX6 Rear panel 800 mm NSYBPSDX8
Frontal door 800 mm NSYDSDX8
Frontal right door 1000 mm NSYDSDX10R
Frontal right door 1200 mm NSYDSDX12R
Frontal left door 1000 mm NSYDSDX10L
Frontal left door 1200 mm NSYDSDX12L
Desk lid 1000 mm NSYDLSDX10
Desk lid 1200 mm NSYDLSDX12
Desk lid 600 mm NSYDLSDX6
Desk lid 800 mm NSYDLSDX8
PB500300-36
S3CM
Description References Description References
Doors Door accessories
Plain door H 200 x W 200 NSYDCRN22 Standard Spacial hinge NSYBICRN
Plain door H 200 x W 300 NSYDCRN23 Earthing accessories
Plain door H 250 x W 200 NSYDCRN2520 Set of 500 earthing labels NSYSWMEL
Plain door H 300 x W 250 NSYDCRN3025 Panels
Plain door H 300 x W 300 NSYDCRN33
Aluminium plate H 300 x W 300 NSYPAS3CM33
Plain door H 300 x W 400 NSYDCRN34
Aluminium plate H 300 x W 400 NSYPAS3CM34
Plain door H 300 x W 450 NSYDCRN3045
Aluminium plate H 400 x W 400 NSYPAS3CM44
Plain door H 400 x W 300 NSYDCRN43
Aluminium plate H 400 x W 600 NSYPAS3CM46
Plain door H 400 x W 400 NSYDCRN44
Aluminium plate H 500 x W 500 NSYPAS3CM55
Plain door H 400 x W 600 NSYDCRN46
Aluminium plate H 600 x W 600 NSYPAS3CM66
Plain door H 500 x W 500 NSYDCRN55
Aluminium plate H 600 x W 800 NSYPAS3CM68
Plain door H 600 x W 600 NSYDCRN66
Aluminium plate H 800 x W 600 NSYPAS3CM86
Plain door H 600 x W 800 NSYDCRN68
Plain door H 800 x W 600 NSYDCRN86
498
Spare parts
Selection table
Spacial S3HD
PB502653-17
Spacial SFHD
PB502653-17
499
Index of
references
500
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
2PLOL... AK2GA69 290 ATV630D75N4 391 AZ1CA04 239 IMT…
2PLOL185 494 AK2GD10075 290 ATV630D90N4 391 DX… IMT36150 284
2PLOL186 494 AK2GD12575 290 ATV630U07M3 391 DX1AP52 251 IMT36151 273
2PLOL205 494 AK2GD2525 290 ATV630U07N4 391 DZ… IMT36152 273
2PLOL206 494 AK2GD2550 290 ATV630U15M3 391 DZ5ME5 263, 268 IMT36153 273
2PLOL208 494 AK2GD3750 290 ATV630U15N4 391 DZ5ME8 263, 268 IMT36154 273
08... AK2GD3775 290 ATV630U22M3 391 DZ5ME9 263, 268 IMT36155 273
08881 282 AK2GD5050 290 ATV630U22N4 391 DZ5MF6 241 IMT36156 273
08892 282 AK2GD5075 290 ATV630U30M3 391 DZ5MF8 241 IMT36157 273
08895 282 AK2GD7550 290 ATV630U30N4 391 DZ5MS10 251 IMT36158 273
08897 282 AK2GD7575 290 ATV630U40M3 391 DZ6MZ121 241 IMT36159 273
08898 282 AK2LA39 289 ATV630U40N4 391 DZ6MZ151 241 IMT36160 273
80099 282 AK2LD01 289 ATV630U55M3 391 DZ6MZ181 241 IMT36161 273
501
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSY11958 462, 464 NSY2SPHD204 312 NSYAC360 199 NSYAEDL2241S3D 490 NSYAEDLS3HFDB3 498
NSY11959 462 NSY2SPHF184 343 NSYAC360 222 NSYAEDL2244S3D 490 NSYAEDLS6S3D 72
NSY11960 462 NSY2SPHF186 343 NSYAC560 220 NSYAEDL2314S3D 490 NSYAEDLS7S3D 72
NSY11961 462 NSY2SPHF2010 343 NSYAC600 199, 222 NSYAEDL2322S3D 490 NSYAEDLS8S3D 72
NSY11962 462 NSY2SPHF204 343 NSYAC840 220, 222 NSYAEDL2331S3D 72 NSYAEDLSD 17, 51, 100
NSY17990 414 NSY2SPHF206 343 NSYADR100 260 NSYAEDL2432S3D 490 NSYAEDLSDS3D 72
NSY17991 414 NSY2SPHF208 343 NSYADR120 260 NSYAEDL2433S3D 72 NSYAEDLT6S3D 72
NSY17992 414 NSY2SPHF226 343 NSYADR200 262 NSYAEDL3113S3D 72 NSYAEDLT8S3D 72
NSY17996 414 NSY2SPHF228 343 NSYADR200D 262 NSYAEDL3123S3D 490 NSYAEDPLA001 496
NSY17997 414 NSY2SPI126 124 NSYADR60 260 NSYAEDL3132S3D 490 NSYAEDPLA002 496
NSY17998 414 NSY2SPI185 124 NSYADR80 260 NSYAEDL3432S3D 490 NSYAEDPLA003 496
NSY1TH 259, 387 NSY2SPI186 124 NSYAEBFZ 199 NSYAEDL405K31 328, NSYAEDPLA004 496
332
NSY2… NSY2SPI188 124 NSYAEBFZ 220, 222 NSYAEDPLA005 496
NSYAEDL405K33 328,
NSY2SP124 116, 118, NSY2SPI204 124 NSYAECPFLA10 278 NSYAEDRS3DPA6 75,
332
124 299
NSY2SPI205 124 NSYAECPFLA25 278
NSYAEDL405S3D 72
NSY2SP125 22, 118, 124 NSYAEDRSCST 61, 75,
NSY2SPI206 124 NSYAECPFLA33 278
NSYAEDL421S3D 72 83, 299, 330, 333
NSY2SP126 20, 22 , 116, NSYAECPFLA7 278
NSY2SPI208 124 NSYAEDL4322S3D 490
118, 124 NSYAEDS20TB 179
NSY2SPI226 124 NSYAECPFLACA14 282
NSY2SP128 22, 118, 124 NSYAEDL4324S3D 490 NSYAEDS40TB 179
NSY2SPI228 124 NSYAECPFLACA18 282
NSY2SP144 20, 22, 116, NSYAEDL455K31 328, NSYAEDS60TB 179
118, 124 NSY2SPIHD124 312 NSYAECPFLACA20 282 332
NSYAEDSB320TB 179
NSY2SP145 22 , 118, 124 NSY2SPIHD126 312 NSYAECPFLACA30 282 NSYAEDL455K33 328,
332 NSYAEDSB520TB 179
NSY2SP146 22, 118, 124 NSY2SPIHD164 312 NSYAECPFLAP 282
NSYAEDL455S3D 72 NSYAEDSBSB 45
NSY2SP148 22, 118, 124 NSY2SPIHD166 312 NSYAECPFLBP 139, 280
NSYAEDL5124S3D 490 NSYAEDST620TB 179
NSY2SP164 22, 118, 124 NSY2SPIHD204 312 NSYAECPFLT25 139,
NSYAEDL520S3D 490 NSYAEDST820TB 179
280
NSY2SP165 22, 118, 124 NSY2SPQ126 124
NSYAEDL601S3D 490 NSYAEDSTSB 45
NSYAECPFLT35 139,
NSY2SP166 20, 22 , 116, NSY2SPQ128 124 280
NSYAEDL610S3D 490 NSYAEFAHLBSC 60, 66,
118, 124
NSY2SPQ146 124 82, 89, 94
NSYAECPFLT7 139, 280
NSY2SP168 20, 22, 116, NSYAEDL705S3D 490
NSY2SPQ148 124 NSYAEFPFPTD 393
118, 124 NSYAECPKFL10 280
NSYAEDLB3S3D 72
NSY2SPQ166 124 NSYAEFPFS3DW100 67,
NSY2SP184 20, 22, 116, NSYAECPKFL11 280
NSYAEDLB5S3D 72 82
118, 124 NSY2SPQ168 124 NSYAECPKFL7A 280
NSYAEDLDINS3D 73 NSYAEFPFS3DW20 67,
NSY2SP185 20, 22, 116, NSY2SPQ186 124 NSYAECPKFL7B 280 82
118, 124 NSYAEDLEDF13K31
NSY2SPQ188 124 NSYAEDH120S3D 73 328, 332 NSYAEFPFS3DW30 67,
NSY2SP186 20, 22, 116,
NSY2SPQ206 124 82
118, 124 NSYAEDH180S3D 73 NSYAEDLEDF13K33
NSY2SPQ208 124 328, 332 NSYAEFPFS3DW40 67,
NSY2SP188 20, 22, 116, NSYAEDH20TB 180 82
118, 124 NSY2SPQ226 124 NSYAEDLEDF13S3D 73
NSYAEDH40TB 180 NSYAEFPFS3DW50 67,
NSY2SP204 20, 23, 116, NSY2SPQ228 124 NSYAEDLEDF14K31
NSYAEDHPLM 497 82
119, 124 328, 332
NSY2SPX184 25, 167 NSYAEDHPLM108 497 NSYAEFPFS3DW60 67,
NSY2SP205 20, 23, 116, NSYAEDLEDF14K33
NSY2SPX204 25, 167 82
119, 124 NSYAEDHPLM3025 497 328, 332
NSY2SPX205 25, 167 NSYAEFPFS3DW80 67,
NSY2SP206 20, 23, 116, NSYAEDHPLM32 497 NSYAEDLEDF14S3D 73
82
119, 124 NSY2SPX206 25, 167 NSYAEDKTB 179 NSYAEDLEDF9K31 328,
NSYAEFPFSB 45
NSY2SP208 20, 23, 116, 332
NSY5… NSYAEDL1242K31 328,
119, 124 NSYAEFPFSC 16, 352
332 NSYAEDLEDF9K33 328,
NSY5G2SP205 325
NSY2SP224 23, 119, 124 332 NSYAEFPFSC 50, 60, 66,
NSY5G2SP206 323 NSYAEDL1242K33 328, 82, 88, 89, 94
NSY2SP225 23, 119, 124 332 NSYAEDLEDF9S3D 73
NSY5G2SP208 323, 325 NSYAEFPFXSC 60, 66,
NSY2SP226 20, 23, 116, NSYAEDL1242S3D 72 NSYAEDLPADS3D 73
82, 94, 312, 352
119, 124 NSY5GRCK42 323
NSYAEDL1332S3D 490 NSYAEDLPADS3DHD
NSYAEFTB 171, 180
NSY2SP228 20, 23, 116, NSY5GSPK 323 312
119, 124 NSYAEDL1344S3D 490 NSYAELYTCRG8 60, 70,
NSYA… NSYAEDLPADS3DK3
NSYAEDL2124S3D 490 82, 99, 330, 333
NSY2SPHD124 312 328, 332
NSYAC1080 220 NSYAELZ 222
NSY2SPHD126 312 NSYAEDL2131S3D 490 NSYAEDLS3DC 491
NSYAC1120 222 NSYAEPZA 220
NSY2SPHD164 312 NSYAEDL2132S3D 490 NSYAEDLS3DKDB3
NSYAC280 199 490, 491, 499 NSYAEPZM 199
NSY2SPHD166 312 NSYAEDL2133S3D 490
NSYAC320 220 NSYAEDLS3DRLN 490
502
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYAES228SB 42 NSYAMRD29357TB 182 NSYB… NSYBN606 261, 268 NSYBPSDX6 498
NSYAES238SB 42 NSYAMRD30357SB 42 NSYB204 261, 268 NSYBN608 261, 268 NSYBPSDX8 498
NSYAES248SB 42 NSYAMRD34155TB 182 NSYB404 261, 268 NSYBN610 261, 268 NSYBRF12PLA 233
NSYAES258SB 42 NSYAMRD343515TB NSYB406 261, 268 NSYBP126 22, 118 NSYBRF17PLA 233
182
NSYAES268SB 42 NSYBANPLA53 231 NSYBP128 22, 118 NSYBRF21PLA 233
NSYAMRD34357TB 182
NSYAES338SB 42 NSYBANPLA54 231 NSYBP146 22, 118 NSYBRF26PLA 233
NSYAMRD40357SB 42
NSYAES348SB 42 NSYBANPLA56 231 NSYBP148 22, 118 NSYBRF35PLA 233
NSYAMRD50357SB 42
NSYAES358SB 42 NSYBANPLA73 231 NSYBP166 22, 118 NSYBRF8PLA 233
NSYAMRD60357SB 42
NSYAES368SB 42 NSYBANPLA74 231 NSYBP168 22, 118 NSYBRP11PLA 233
NSYAMRD80357SB 42
NSYAEUBU148 42 NSYBANPLA76 231 NSYBP1810 22, 118 NSYBRP16PLA 233
NSYAPFWM 89
NSYAEUBU41SC 98 NSYBCE10 135 NSYBP1812 22, 118 NSYBRP20PLA 233
NSYAPFXWM 97, 155,
NSYAEUBU61SC 98 NSYBCE12 135 NSYBP184 22, 118 NSYBRP25PLA 233
312
NSYAEUBUSC 98 NSYBCE16 135 NSYBP186 22, 118 NSYBRP7PLA 233
NSYAPU10F3 293
NSYAMCSF 87, 236, 241, NSYBCE3 135 NSYBP188 22, 118 NSYBTAS3D100 490,
NSYAPU10F3S 293
268 491, 499
NSYBCE4 135 NSYBP2010 23, 119
NSYAPU10S3 293
NSYAMFEP154TB 181, NSYBTAS3D120 490,
NSYBCE6 135 NSYBP2012 23, 119
182 NSYAPU10S3S 293 491
NSYBCE8 135 NSYBP2016 23, 119
NSYAMFEP204TB 181, NSYAPU19F6CB 293 NSYBTAS3D140 490
182 NSYBCME 101, 166, 203 NSYBP203 23, 119
NSYAPU19F7FA 293 NSYBTAS3D60 490, 491,
NSYAMFEP304TB 181, NSYBCPL 26, 101, 203, NSYBP204 23, 119 499
NSYAPU19F8S 293
182 352
NSYBP206 23, 119 NSYBTAS3D70 490, 491,
NSYAPU19F9 293
NSYAMFESTB 181, 182 NSYBCPLA 225 499
NSYBP207 493
NSYAPU19S6CB 293
NSYAMFET154TB 181, NSYBE27 190, 191 NSYBTAS3D80 490, 491,
182 NSYBP208 23, 119 499
NSYAPU19S7FA 293
NSYBGN1054HD 226,
NSYAMFET204TB 181, NSYBP2210 23, 119 NSYBU108PLM 27, 201
NSYAPU19S8S 293 310
182 NSYBP2212 23, 119
NSYAPU19S9 293 NSYBGN1074HD 226, NSYBUPLM 27, 201
NSYAMFET304TB 181, 310 NSYBP224 23, 119
182 NSYAPU19UK6S 293 NSYC…
NSYBGN12124HD 226, NSYBP226 23, 119
NSYAMFSB 42, 45 NSYAPU19UK7 293 NSYCAAPV 413
310
NSYBP228 23, 119
NSYAMFSTB 171, 181, NSYAPUB 293 NSYCAAPVHD 315, 413
NSYBGN12126HD 226,
182 NSYBPA7032 303
NSYAPUBV 293 310 NSYCAC228RMF 420
NSYAMPA1916TB 181 NSYBPA7035 303
NSYAPUF10S 293 NSYBGN1254HD 226, NSYCAEFPF 490
NSYAMPA2419TB 181 310 NSYBPC3 289
NSYAPUF12CB 293 NSYCAF104X95X 420
NSYAMPA2924TB 181 NSYBGN1274HD 226, NSYBPC5 289
NSYAPUS10S 293 NSYCAF108 416
310
NSYAMPA3429TB 181 NSYBPI126 124
NSYAPUS12CB 293 NSYCAF125 412
NSYBGN1276HD 226,
NSYAMPM1916TB 181 310 NSYBPI166 124
NSYAS25 190 NSYCAF125L55 412,
NSYAMPM2419TB 181 NSYBGN15124HD 226, NSYBPI168 124 414
NSYASPLA001 496
310 NSYBPI1810 124 NSYCAF125M 412
NSYAMPM2924TB 181 NSYASPLA002 496
NSYBGN15126HD 226, NSYBPI186 124 NSYCAF125O 412
NSYAMPM3429TB 181 NSYASPLA003 496 310
NSYAMRD11155TB 182 NSYBPI188 124 NSYCAF125T 412
NSYASPLM 497 NSYBGN1574HD 226,
NSYAMRD11357TB 182 310 NSYBPI2010 124 NSYCAF130X110X 420
NSYASPLM32 497
NSYAMRD15357SB 42 NSYBGN1576HD 226, NSYBPI2012 124 NSYCAF170X190X 420
NSYATM27 189
310 NSYBPI204 124 NSYCAF190 315, 317,
NSYAMRD16155TB 182 NSYATP72G 88
NSYBGN2074HD 310 413
NSYAMRD16357TB 182 NSYBPI206 124
NSYATP72MS 155
NSYBGN774HD 226, 310 NSYCAF223 412
NSYAMRD19155TB 182 NSYBPI208 124
NSYAUPG1 205, 219
NSYBGN776HD 226, 310 NSYCAF223L55 412,
NSYAMRD19357TB 182 NSYBPI2210 124
NSYAUPG5 205, 219 414
NSYBICRN 492, 498 NSYBPI226 124
NSYAMRD20357SB 42 NSYAUPGS 205, 219 NSYCAF223M 412
NSYBL27 190 NSYBPI228 124
NSYAMRD24155TB 182 NSYAVD1U1450 418 NSYCAF223O 412
NSYBLKH123 146 NSYBPSD10 497
NSYAMRD243515TB NSYAVD1U480 418 NSYCAF223T 315, 317,
182 NSYBN204 261, 268 NSYBPSD12 497 412, 413
NSYAVD1U550M48 418
NSYAMRD24357TB 182 NSYBN206 261, 268 NSYBPSD6 497 NSYCAF228R 420
NSYAVD1U970 418
NSYAMRD29155TB 182 NSYBN404 261, 268 NSYBPSD8 497 NSYCAF291 412
NSYAVG2U300 418
NSYAMRD293515TB NSYBN406 261, 268 NSYBPSDX10 498 NSYCAF291L55 412,
182 NSYAZ3PLA 221
NSYBN408 261, 268 414
NSYBPSDX12 498
NSYAZ4PLA 221
503
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYCAF291M 412 NSYCAP291LE 414, 415, NSYCEJD16 281 NSYCEWX15K 429, 433 NSYCL27L405 185, 190
422
NSYCAF291O 412 NSYCEJD18 281 NSYCEWX15K2P4 429, NSYCL27M 185, 190
NSYCAP291LXF 412, 433
NSYCAF291T 412 415, 422 NSYCEJD20 281 NSYCL405CRN 35, 100
NSYCEWX1K 429, 433
NSYCAF92 412 NSYCAP291LZF 412, NSYCEJD22 281 NSYCL405CSX 157
NSYCEWX1K8 429, 433
NSYCAF92M 412 415, 422 NSYCEJD24 281 NSYCL610CSX 157
NSYCEWX1K8UL 429,
NSYCAG104X95LM 420 NSYCBCCRN 100 NSYCEJD26 281 NSYCLL405CRN 100,
433
NSYCBCMPLA 225 343
NSYCAG108LP 416 NSYCEJD28 281 NSYCEWX1KUL 429,
NSYCBLSF 143 433 NSYCMACS50 365
NSYCAG110X46M 420 NSYCEJD3 281
NSYCCASTE 462 NSYCEWX2K5 429, 433 NSYCMACS80 365
NSYCAG114LPF 417 NSYCEJD30 281
NSYCCOHY120VID 461 NSYCEWX2K5UL 429, NSYCMBPC 362
NSYCAG125LPC 412, NSYCEJD5 281
422 433 NSYCMBPT 362
NSYCCOHY230VID 461 NSYCEJD7 281
NSYCAG125LPF 211, NSYCEWX3K5 429, 433 NSYCMSPP 362
NSYCCOHY30VID 461 NSYCEJD9 281
219, 412, 414, 422 NSYCEWX3K5UL 429,
NSYCCOHYT120VID 461 NSYCMT2560110 362
NSYCEK 135 433
NSYCAG12LPH1 178,
NSYCCOHYT230VID 461 NSYCMT5005 363, 366
421 NSYCEP 302 NSYCEWX4K5 429, 433
NSYCCOHYT30VID 461 NSYCMT5010 363, 366
NSYCAG12LPH2 178, NSYCEPLMA 27, 200 NSYCEWX4K5UL 429,
421 433 NSYCMT5015 363, 366
NSYCCOTH120VID 461 NSYCEPLMB 27, 200
NSYCAG130X110LM NSYCEWX6K 429, 433 NSYCMT5020 363, 366
NSYCCOTH230VID 461 NSYCEPLMC 27, 200
420
NSYCCOTH30VID 461 NSYCEWX6K2P4 429, NSYCMT8005 363, 366
NSYCAG170X190LM NSYCESD10R 497
433 NSYCMT8010 363, 366
420 NSYCCOTHC 460 NSYCESD12R 497
NSYCEWX6KUL 429, NSYCMT8015 363, 366
NSYCAG180X62M 420 NSYCCOTHCF 460 NSYCESD6R 497 433
NSYCAG19LP 421 NSYCCOTHD 460 NSYCMT8020 363, 366
NSYCESD8R 497 NSYCEX1 496
NSYCAG216X62M 420 NSYCCOTHDF 460 NSYCMUCC50 365, 366
NSYCEW10K 429, 433 NSYCEX10 495
NSYCAG223LFHD 315, NSYCCOTHI 460 NSYCMUCC80 365, 366
NSYCEW10K2P4 429, NSYCEX11 495
413 433 NSYCMUCP50 365, 366
NSYCCOTHIF 460 NSYCEX12 495
NSYCAG223LPC 412, NSYCEW15K 429, 433 NSYCMUCP80 365, 366
422 NSYCCOTHO 460 NSYCEX13 496, 498
NSYCCOTHOF 460 NSYCEW15K2P4 429, NSYCMUCPAD87 364,
NSYCAG223LPF 317, 433 NSYCEX14 495 366
412, 414, 422 NSYCCSDF10 497
NSYCEW1K 429, 433 NSYCEX15 495 NSYCMUCR50 365, 366
NSYCAG291LPC 412, NSYCCSDF12 497
NSYCEW1K8 429, 433 NSYCEX16 495, 498 NSYCMUCR80 365, 366
422
NSYCCSDF16 497 NSYCEX17 495
NSYCAG291LPF 412, NSYCEW1K8UL 429, NSYCMUIA50 364, 366
414, 416, 422 NSYCCSDF8 497 433 NSYCEX2 495, 496 NSYCMUIA80 364, 366
NSYCAG317X120M 420 NSYCDB3 100, 492 NSYCEW1KUL 429, 433 NSYCEX3 496, 498 NSYCMUMA50 364, 366
NSYCAG317X91M 420 NSYCDBPLM 202 NSYCEW2100W230VL NSYCEX4 496 NSYCMUMA80 364, 366
433
NSYCAG33LP 421 NSYCDL 291 NSYCEX5 495 NSYCMUMC50 364, 366
NSYCEW2K5 429, 433
NSYCAG35LP 205, 421 NSYCDRB 291 NSYCEX6 495 NSYCMUMC80 364, 366
NSYCEW2K5R 429, 433
NSYCAG38LP 421 NSYCDS 291 NSYCEX7 495, 496, 498 NSYCMUMR50 364, 366
NSYCEW2K5UL 429,
NSYCAG417X120M 420 NSYCEA14E 425, 433 NSYCEX8 495
433 NSYCMUMR80 364, 366
NSYCAG45LP 421 NSYCEA15W230VL 433 NSYCEX84A 496
NSYCEW3150W230VL NSYCMUTC50 365, 366
NSYCAG78LPF 417 NSYCEA35W230VL 433 433 NSYCEX9 495 NSYCMUTC80 365, 366
NSYCAG92LPC 412, 422 NSYCEA35W230VLE NSYCEW3K5 429, 433 NSYCFP100 286
433 NSYCN20 261
NSYCAG92LPF 412, 422 NSYCEW3K5UL 429, NSYCFP60 286
NSYCEA36 425, 433 433 NSYCN40 261
NSYCAP125LE 414, 415, NSYCFP80 286 NSYCN9M625 131, 267
422 NSYCEA50 425, 433 NSYCEW4K5 429, 433
NSYCFS126 286 NSYCNFM6 268
NSYCAP125LXF 412, NSYCEA70W230VL 433 NSYCEW4K5UL 429,
415, 422 433 NSYCFS128 286 NSYCNFM8 268
NSYCEA80 425, 433
NSYCAP125LZF 412, NSYCEW6K 429, 433 NSYCFS96 286 NSYCNM6 250, 268
NSYCEARTFIT14 433
415, 422 NSYCEW6K2P4 429, 433 NSYCFS98 286
NSYCEARTFIT36 433 NSYCNM8 250, 268
NSYCAP223LE 414, 415, NSYCEW6KUL 429, 433 NSYCHCOA 89, 96
NSYCEARTFIT80 433 NSYCNOH123 146
422
NSYCEWRTFIT2K5 433 NSYCHCOB 89, 96 NSYCNT20 261
NSYCAP223LXF 412, NSYCEJ 135
415, 422 NSYCEWRTFIT3K5 433 NSYCHCOC 89, 96 NSYCNT40 261
NSYCEJD 281
NSYCAP223LZF 412, NSYCEWX10K 429, 433 NSYCHCOD 89, 96 NSYCOCN80 89, 96
NSYCEJD11 281
415, 422 NSYCEWX10K2P4 429, NSYCL1242ECSX 157
NSYCEJD13 281 NSYCOCNS1400 89, 96
433
NSYCL220CRN 100 NSYCOCNS1800 89, 96
504
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYCPT17 289 NSYCRN108300 14, 86 NSYCRN64200 14, 86 NSYCRNG1012400D 14, NSYCS400PLM 27, 204
86
NSYCPT29 289 NSYCRN108300P 14, 86 NSYCRN64200P 14, 86 NSYCS500PLM 27, 204
NSYCRNG106400 14, 86
NSYCPT37 289 NSYCRN108300T 14, 86 NSYCRN64200T 14, 86 NSYCS600PLM 27, 204
NSYCRNG106400T 14,
NSYCPT50 289 NSYCRN22150 14, 86 NSYCRN64250 14, 86 NSYCS800PLM 27, 204
86
NSYCPTS17 289 NSYCRN23150 14, 86 NSYCRN64250P 14, 86 NSYCSP 125
NSYCRNG108400 14, 86
NSYCPTS29 289 NSYCRN252150 14, 86 NSYCRN64250T 14, 86 NSYCSSF 493
NSYCRNG108400T 14,
NSYCPTS37 289 NSYCRN252150P 14, 86 NSYCRN65150 14, 86 86 NSYCTL300DLA 207
NSYCPTS50 289 NSYCRN325150 14, 86 NSYCRN65150P 14, 86 NSYCRNG1210300D 14, NSYCTL300DLM 88
86
NSYCR100WU1 458 NSYCRN325150P 14, 86 NSYCRN65150T 14, 86 NSYCTL400DLA 207
NSYCRNG1210400D 14,
NSYCR100WU1C 456 NSYCRN325150T 14, 86 NSYCRN65200 14, 86 86 NSYCTL400DLM 88
NSYCR100WU2 458 NSYCRN325200 14, 86 NSYCRN65200P 14, 86 NSYCRNG1212300D 14, NSYCTL500DLA 207
NSYCR100WU2C 456 NSYCRN325200P 14, 86 NSYCRN65200T 14, 86 86 NSYCTL500DLM 88
NSYCR100WU3 458 NSYCRN325200T 14, 86 NSYCRN65250 14, 86 NSYCRNG1212400D 14, NSYCTL500DLP 232
86
NSYCR100WU3C 456 NSYCRN33150 14, 86 NSYCRN65250P 14, 86 NSYCTL600DLA 207
NSYCRNG126300 14, 86
NSYCR10WU1 458 NSYCRN33150P 14, 86 NSYCRN65250T 14, 86 NSYCTL600DLM 88
NSYCRNG126300T 14,
NSYCR10WU1C 456 NSYCRN33150T 14, 86 NSYCRN66200 14, 86 86 NSYCTL750DLP 232
NSYCR10WU2 458 NSYCRN33200 14, 86 NSYCRN66200T 14, 86 NSYCRNG126400 14, 86 NSYCTL800DLA 207
NSYCR10WU2C 456 NSYCRN33200P 14, 86 NSYCRN66250 14, 86 NSYCRNG126400T 14, NSYCTL800DLM 88
NSYCR150WU1 458 NSYCRN33200T 14, 86 86
NSYCRN66250P 14, 86 NSYCU1050W230VL 450
NSYCR150WU1C 456 NSYCRN34200 14, 86 NSYCRNG128300 14, 86
NSYCRN66250T 14, 86 NSYCU1050W230VR
NSYCRNG128300T 14, 450
NSYCR150WU2 458 NSYCRN34200T 14, 86 NSYCRN66300 14, 86
86
NSYCU10K3P4 438, 450
NSYCR150WU2C 456 NSYCRN345150 14, 86 NSYCRN66300P 14, 86
NSYCRNG128400 14, 86
NSYCU10K3P460 438,
NSYCR150WU3 458 NSYCRN43150 14, 86 NSYCRN66300T 14, 86
NSYCRNG128400T 14, 450
NSYCR170W230VVC NSYCRN43150P 14, 86 NSYCRN68300 14, 86 86
NSYCU1460W230VR
456
NSYCRN43150T 14, 86 NSYCRN68300T 14, 86 NSYCRNG1410300D 14, 450
NSYCR20WU1 458 86
NSYCRN43200 14, 86 NSYCRN75200 14, 86 NSYCU15K3P4 438, 450
NSYCR20WU1C 456 NSYCRNG810300D 14,
NSYCRN43200P 14, 86 NSYCRN75200P 14, 86 NSYCU15K3P460 438,
86
NSYCR20WU2 458 450
NSYCRN43200T 14, 86 NSYCRN75200T 14, 86
NSYCRNG812300D 14,
NSYCR20WU2C 456 NSYCU1650W230VL 450
NSYCRN44200 14, 86 NSYCRN75250 14, 86 86
NSYCR20WU3 458 NSYCU1650W230VR
NSYCRN44200P 14, 86 NSYCRN75250P 14, 86 NSYCRNG86400 14, 86
450
NSYCR250W115VV 458
NSYCRN44200T 14, 86 NSYCRN75250T 14, 86 NSYCRNG86400T 14, 86
NSYCU1800W400VL 450
NSYCR250W230VV 458
NSYCRN46250 14, 86 NSYCRN86200 14, 86 NSYCRNGSDR 15, 87,
NSYCU1K 436, 450
NSYCR400W115VV 458 237, 240
NSYCRN46250P 14, 86 NSYCRN86200P 14, 86 NSYCU1K2 436, 450
NSYCR400W230VV 458 NSYCRP1W120VTVC
NSYCRN46250T 14, 86 NSYCRN86200T 14, 86 458 NSYCU1K22P4 436, 450
NSYCR50WU1C 456
NSYCRN46300 14, 86 NSYCRN86250 14, 86 NSYCRP1W230VTVC NSYCU1K2P4 436, 450
NSYCR50WU2C 456 458
NSYCRN46300T 14, 86 NSYCRN86250P 14, 86 NSYCU1K2P4UL 436,
NSYCR50WU3C 456 NSYCRS100W120V 453 450
NSYCRN54150 14, 86 NSYCRN86250T 14, 86
NSYCR55WU1 458 NSYCRS100W240V 453 NSYCU1K2R 440, 450
NSYCRN54150P 14, 86 NSYCRN86300 14, 86
NSYCR55WU2 458 NSYCRS10W120V 453 NSYCU1K2RUL 440, 450
NSYCRN54150T 14, 86 NSYCRN86300P 14, 86
NSYCR55WU3 458 NSYCRS10W240V 453 NSYCU1K2UL 436, 450
NSYCRN54200 14, 86 NSYCRN86300T 14, 86
NSYCRAF 458 NSYCRS200W115V 458 NSYCU1K5R 440, 450
NSYCRN54200P 14, 86 NSYCRN88200 14, 86
NSYCRAFD 458 NSYCRS200W120V 453 NSYCU1K5RUL 440, 450
NSYCRN54200T 14, 86 NSYCRN88200P 14, 86
NSYCRN106250 14, 86 NSYCRS200W230V 458 NSYCU1K6 436, 450
NSYCRN54250 14, 86 NSYCRN88200T 14, 86
NSYCRN106250P 14, 86 NSYCRS200W240V 453 NSYCU1K62P4 436, 450
NSYCRN54250P 14, 86 NSYCRN88300 14, 86
NSYCRN106250T 14, 86 NSYCRS25W120V 453 NSYCU1K62P4UL 436,
NSYCRN54250T 14, 86 NSYCRN88300P 14, 86
NSYCRN106300 14, 86 450
NSYCRN55250 14, 86 NSYCRN88300T 14, 86 NSYCRS25W240V 453
NSYCRN106300P 14, 86 NSYCU1K6UL 436, 450
NSYCRN55250P 14, 86 NSYCRNG1010300D 14, NSYCRS50W120V 453
NSYCRN106300T 14, 86 86 NSYCU1KUL 436, 450
NSYCRN55250T 14, 86 NSYCRS50W240V 453
NSYCRN108250 14, 86 NSYCRNG1010300T 14, NSYCU2000W400VR
NSYCRN64150 14, 86 NSYCS200PLM 27, 195,
86 450
NSYCRN108250P 14, 86 204
NSYCRN64150P 14, 86 NSYCU240W230VL 450
NSYCRNG1012300D 14, NSYCS300PLM 27, 204
NSYCRN108250T 14, 86
NSYCRN64150T 14, 86 86
505
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYCU2450W400VR NSYCUB2200W230S NSYCUFX6K 450 NSYCUSX3K23P4UL NSYCVF165M24DPF
450 450 444, 450 408, 422
NSYCUFX800R 450
NSYCU2500W400VL 450 NSYCUB2200W400S NSYCUSX3K2UL 444, NSYCVF165M48DPF
NSYCUFX800T1K 450
450 450 408, 422
NSYCU2K 436, 450
NSYCUFX8KT10K 450
NSYCUB2700W230S NSYCUX1K 436, 450 NSYCVF170M115 418
NSYCU2K3P4 438, 450
450 NSYCUHD1K 443, 450
NSYCUX1K2 436, 450 NSYCVF170M230 418
NSYCU2K3P4R 440, 450
NSYCUB2700W400S NSYCUHD1K2P4 443,
NSYCUX1K22P4 436, NSYCVF300M115PF
NSYCU2K3P4RUL 440, 450 450
450 408, 422
450
NSYCUCN1K2T2KHD NSYCUHD1K6 443, 450
NSYCUX1K2P4 436, 450 NSYCVF300M230PF
NSYCU2K3P4UL 438, 450
NSYCUHD1K62P4 443, 408, 412, 414, 422
450 NSYCUX1K2P4UL 436,
NSYCUCN3KT4KHD 450 450
450 NSYCVF300M24DPF
NSYCU2KR 440, 450
NSYCUCN400HD 450 NSYCUHD2K3P4 443, 408, 422
NSYCUX1K2R 440, 450
NSYCU2KUL 436, 450 450
NSYCUCN600HD 450 NSYCVF300M48DPF
NSYCUX1K2UL 436, 450
NSYCU300H 436, 450 NSYCUHD3K3P4 443, 408, 422
NSYCUCN800T1KHD
450 NSYCUX1K5R 440, 450
NSYCU3100W400VR 450 NSYCVF35M115 417
450 NSYCUHD400 443, 450 NSYCUX1K6 436, 450
NSYCUD1K1T1K5 450 NSYCVF35M230 417
NSYCU370W230VL 450 NSYCUHD4K3P4 443, NSYCUX1K62P4 436,
NSYCUD1K2T2K 450 NSYCVF38M115PF 408,
450 450
NSYCU3K3P4 438, 450 422
NSYCUD3KT4K 450
NSYCUHD600 443, 450 NSYCUX1K62P4UL 436,
NSYCU3K3P4R 440, 450 NSYCVF38M230PF 408,
NSYCUD400 450 450
NSYCUHD800 443, 450 422
NSYCU3K3P4RUL 440,
NSYCUD600 450 NSYCUX1K6UL 436,
450 NSYCURFT1K2T2K 450 NSYCVF38M24DPF 408,
450
NSYCUD800T1K 450 422
NSYCU3K3P4UL 438, NSYCURFT1K6T2K 450
NSYCUX1KUL 436, 450
450 NSYCUE1100W230L 450 NSYCVF38M48DPF 408,
NSYCURFT3K 450 422
NSYCUX2K 436, 450
NSYCU400 436, 450 NSYCUE1400W230L 450
NSYCURFT3KT4K 450 NSYCVF54M230MM2
NSYCUX2K3P4 438, 450
NSYCU4000W400VL 450 NSYCUE1400W230R 416
NSYCURFT400 450
450 NSYCUX2K3P4R 440,
NSYCU400R 440, 450 NSYCVF550M115FB
NSYCURFT800R 450 450
NSYCUE1400W400L 450 315, 413
NSYCU400RUL 440, 450
NSYCURFT800T1K 450 NSYCUX2K3P4UL 438,
NSYCUE1800W400L 450 NSYCVF550M230FB
NSYCU400UL 436, 450 450
NSYCUS1K12P4UL 444, 315, 413
NSYCUE1800W400R
NSYCU4K3P4 438, 450 450 NSYCUX2KR 440, 450
450 NSYCVF550M24FB 315,
NSYCU4K3P4R 440, 450 NSYCUS1K1UL 444, 450 NSYCUX2KUL 436, 450 413
NSYCUF15K 450
NSYCU4K3P4RUL 440, NSYCUS1K52P4UL 444, NSYCUX3K3P4 438, 450 NSYCVF560M115PF
NSYCUF1K1T2KS 450
450 450 408, 422
NSYCUX3K3P4R 440,
NSYCUF1K2T2KR 450
NSYCU4K3P4UL 438, NSYCUS1K5UL 444, 450 450 NSYCVF560M230PF
450 NSYCUF1KT2K 450 408, 412, 414, 422
NSYCUS2K3P460UL NSYCUX3K3P4UL 438,
NSYCU600 436, 450 NSYCUF2K5T3K2S 450 450 450 NSYCVF570M115MF 416
NSYCU600UL 436, 450 NSYCUF3KT4K 450 NSYCUS2K3P4UL 444 NSYCUX400 436, 450 NSYCVF575M230MF
NSYCU6K3P4 438, 450 NSYCUF3KT4KR 450 NSYCUS2K53P4UL 444, NSYCUX400R 440, 450 416
450 NSYCVF65M115PF 416
NSYCU6K3P460 438, NSYCUF400 450 NSYCUX4K3P4 438, 450
450 NSYCUS2K5UL 444, 450 NSYCVF65M230PF 416
NSYCUF400R 450 NSYCUX4K3P4R 440,
NSYCU760W230VL 450 NSYCUS2KUL 444, 450 450 NSYCVF850M115PF
NSYCUF600 450
NSYCU760W230VR 450 NSYCUS3K23P4UL 444, NSYCUX4K3P4UL 438, 408, 422
NSYCUF6K 450 450
450 NSYCVF850M230PF
NSYCU800 436, 450
NSYCUF800R 450 NSYCUX600 436, 450 408, 412, 414, 422
NSYCUS3K2UL 444, 450
NSYCU800R 440, 450
NSYCUF800T1K 450 NSYCUX600UL 436, 450 NSYCVF850M400PF
NSYCUSX1K12P4UL
NSYCU800RUL 440, 450 408, 422
NSYCUF8KT10K 450 444, 450
NSYCUX800 436, 450
NSYCU800UL 436, 450 NSYCVF85M115PF 408,
NSYCUFX15K 450 NSYCUSX1K1UL 444,
NSYCUX800R 440, 450 422
NSYCU8K3P4 438, 450 450
NSYCUFX1K1T2KS 450 NSYCUX800UL 436, 450
NSYCUSX1K52P4UL NSYCVF85M230PF 408,
NSYCU8K3P460 438,
NSYCUFX1K2T2K 450 444, 450 NSYCVA114M 417 412, 414, 422
450
NSYCUFX1K2T2KR 450 NSYCUSX1K5UL 444, NSYCVA78M 417 NSYCVF85M24DPF 408,
NSYCUB1100W230S
450 422
450 NSYCUFX2K5T3K2S NSYCVAC100 417
450 NSYCUSX2K3P4UL NSYCVF85M48DPF 408,
NSYCUB1100W400S
NSYCVF156M115 417 422
450 NSYCUFX3KT4K 450 444, 450
NSYCVF156M230 417 NSYCW33 300
NSYCUB1500W230S NSYCUFX3KT4KR 450 NSYCUSX2K53P4UL
450 444, 450 NSYCVF165M115PF NSYCW44 300
NSYCUFX400 450 408, 422
NSYCUB1500W400S NSYCUSX2K5UL 444, NSYCW45 300
450 NSYCUFX400R 450 450 NSYCVF165M230PF
408, 412, 414, 422 NSYCW46 300
NSYCUFX600 450 NSYCUSX2KUL 444, 450
506
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYCW54 300 NSYDCRN22 492, 498 NSYDLA48P 27, 206, NSYDLSD12 497 NSYDPLM350 26, 27,
207 204, 352
NSYCW55 300 NSYDCRN23 492, 498 NSYDLSD6 497
NSYDLA48PG 88 NSYDPLM43 497
NSYCW56 300 NSYDCRN2520 492, 498 NSYDLSD8 497
NSYDLA66 27, 206, 207 NSYDPLM43T 497
NSYCW65 300 NSYDCRN3025 492, 498 NSYDLSDF10 497
NSYDLA66G 88 NSYDPLM54 497
NSYCW66 300 NSYDCRN3025T 492 NSYDLSDF12 497
NSYDLA84 27, 206, 207 NSYDPLM54T 497
NSYCW86 300 NSYDCRN3045 492, 498 NSYDLSDF16 497
NSYDLA84G 88 NSYDPLM64 497
NSYD… NSYDCRN33 492, 498 NSYDLSDF8 497
NSYDLA88 27, 206, 207 NSYDPLM64T 497
NSYDA1510M 12, 34 NSYDCRN33T 492 NSYDLSDX10 498
NSYDLA88G 88 NSYDPLM75 497
NSYDA2015M 12, 34 NSYDCRN34 492, 498 NSYDLSDX12 498
NSYDLCR110 88 NSYDPLM75T 497
NSYDA2520M 12, 34 NSYDCRN34T 492 NSYDLSDX6 498
NSYDLCR135 88 NSYDPLM86 497
NSYDAN1510 12, 34 NSYDCRN43 492, 498 NSYDLSDX8 498
NSYDLCR18 88 NSYDPLM86T 497
NSYDAN2015 12, 34 NSYDCRN43T 492 NSYDPA3 142, 297
NSYDLCR24 88 NSYDPR100 260
NSYDAN2015D 12, 35 NSYDCRN44 492, 498 NSYDPA4 16, 50, 142,
NSYDLCR36 88 297 NSYDPR120 260
NSYDAN2520 12, 34 NSYDCRN44T 492
NSYDLCR48 88 NSYDPA44 16, 50, 142, NSYDPR200 262
NSYDAN2520D 12, 35 NSYDCRN46 492, 498
155, 297
NSYDLCR64 88 NSYDPR200D 262
NSYDAN3025D 12, 35 NSYDCRN46T 492
NSYDPA5 142, 297
NSYDLCR88 88 NSYDPR200T 262
NSYDAN3530D 12, 35 NSYDCRN54 492
NSYDPLA105 496
NSYDLLSDF 497 NSYDPR25 260
NSYDB1010M 12, 34 NSYDCRN54T 492
NSYDPLA105H 496
NSYDLM168 88 NSYDPR35 260
NSYDB1510M 12, 34 NSYDCRN55 492, 498
NSYDPLA107 496
NSYDLM24 88, 155 NSYDPR45 260
NSYDB2015M 12, 34 NSYDCRN55T 492
NSYDPLA107H 496
NSYDLM240 88, 155 NSYDPR55 260
NSYDB2520M 12, 34 NSYDCRN64 492
NSYDPLA125 496
NSYDLM48 88, 155 NSYDPR60 260
NSYDB3025M 12, 34 NSYDCRN64T 492
NSYDPLA125H 496
NSYDLM48P 88, 155 NSYDPR65 260
NSYDB3530M 12, 34 NSYDCRN65 492
NSYDPLA127 496
NSYDLM48P 88 NSYDPR75 260
NSYDB88M 12, 34 NSYDCRN65T 492
NSYDPLA127H 496
NSYDLM66/NSYDLM88 NSYDPR80 260
NSYDBN1010 12, 34 NSYDCRN66 492, 498
88 NSYDPLA155 496
NSYDS3D1010 490
NSYDBN1510 12, 34 NSYDCRN66T 492
NSYDLM84 88, 155 NSYDPLA155H 496
NSYDS3D1010T 490
NSYDBN2015 12, 34 NSYDCRN68 492, 498
NSYDLM112 88 NSYDPLA157 496
NSYDS3D105L 490
NSYDBN2015D 12, 35 NSYDCRN68T 492
NSYDLM84P 88, 155 NSYDPLA157H 496
NSYDS3D105R 490
NSYDBN2520 12, 34 NSYDCRN75 492
NSYDLP114 228, 30 NSYDPLA3 230
NSYDS3D105TL 490
NSYDBN2520D 12, 35 NSYDCRN75T 492
NSYDLP114P 228, 30 NSYDPLA4 230
NSYDS3D105TR 490
NSYDBN3025 12, 34 NSYDCRN86 492, 498
NSYDLP132 228, 30 NSYDPLA55 496
NSYDS3D106 490
NSYDBN3025D 12, 35 NSYDCRN86T 492
NSYDLP133 228, 30 NSYDPLA55H 496
NSYDS3D106L 490
NSYDBN3530 12, 34 NSYDCRN88 492
NSYDLP152 228, 30 NSYDPLA57 496
NSYDS3D106R 490
NSYDBN3530D 12, 35 NSYDCRN88T 492
NSYDLP165 228, 30 NSYDPLA57H 496
NSYDS3D106T 490, 491
NSYDBN88 12, 34 NSYDHS18 494
NSYDLP171 228, 30 NSYDPLA6 230
NSYDS3D108 490, 499
NSYDBP 100, 202 NSYDHS6 494
NSYDLP198 228, 30 NSYDPLA75 496
NSYDS3D108T 490, 491
NSYDBP 492 NSYDHSF 493
NSYDLP198P 228, 30 NSYDPLA75H 496
NSYDS3D1210 490
NSYDCE10 134 NSYDHSM2D 493
NSYDLP231 228, 30 NSYDPLA77 496
NSYDS3D1210T 490
NSYDCE12 134 NSYDL10 379
NSYDLP264 228, 30 NSYDPLA77H 496
NSYDS3D125L 490
NSYDCE168 280 NSYDL12 379
NSYDLP297 228, 30 NSYDPLM108 497
NSYDS3D125R 490
NSYDCE240 280 NSYDL16 379
NSYDLP57 228, 30 NSYDPLM108T 497
NSYDS3D125TL 490
NSYDCE2410 280 NSYDL6 379
NSYDLP76 228, 30 NSYDPLM200 26, 27,
204, 352 NSYDS3D125TR 490
NSYDCE244 280 NSYDL8 379
NSYDLP95 228, 30
NSYDPLM250 26, 27, NSYDS3D126 490
NSYDCE6 134 NSYDLA112 27, 206, 207
NSYDLP99 228, 30
204, 352 NSYDS3D126L 490
NSYDCE8 134 NSYDLA234 27, 206, 207
NSYDLPLM18 27, 207
NSYDPLM300 26, 27, NSYDS3D126R 490
NSYDCM20 143, 166, NSYDLA234G 88 204, 352
NSYDLS12 186
297 NSYDS3D126T 490
NSYDLA24 27, 206, 207 NSYDPLM3025 497
NSYDLS24 186
NSYDCRN106 492 NSYDS3D128 490
NSYDLA24G 88 NSYDPLM3025T 497
NSYDLS242 186
NSYDCRN106T 492 NSYDS3D128T 490
NSYDLA48 27, 206, 207 NSYDPLM32 497
NSYDLS36 186
NSYDCRN108 492 NSYDS3D145L 490
NSYDLA48G 88 NSYDPLM32T 497
NSYDLS48 186
NSYDCRN108T 492 NSYDS3D145R 490
NSYDLSD10 497
507
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYDS3D32 490, 499 NSYDS3DB64 491 NSYDS3X33 495 NSYDSFX1812RH 495 NSYEC1251 20, 116, 134
NSYDS3D325 490 NSYDS3DC1010 491 NSYDS3X33H 495 NSYDSFX1816L 495 NSYEC126 20, 116, 134
NSYDS3D325T 490 NSYDS3DC106 491 NSYDS3X43 495 NSYDSFX1816LH 495 NSYEC1261 20, 116, 134
NSYDS3D33 490, 499 NSYDS3DC108 491 NSYDS3X43H 495 NSYDSFX1816R 495 NSYEC1262 20, 116, 134
NSYDS3D33T 490 NSYDS3DC1210 491 NSYDS3X43T 495 NSYDSFX1816RH 495 NSYEC128 20, 116, 134
NSYDS3D34 490 NSYDS3DC128 491 NSYDS3X44 495 NSYDSFX186 495, 496 NSYEC1281 20, 116, 134
NSYDS3D34T 490 NSYDS3DC32 491 NSYDS3X44H 495 NSYDSFX188 495, 496 NSYEC1282 20, 116, 134
NSYDS3D36T 490 NSYDS3DC33 491 NSYDS3X46 495 NSYDSFX188H 495 NSYEC164 20, 116, 134
NSYDS3D43 490, 499 NSYDS3DC43 491 NSYDS3X46H 495 NSYDSFX2010L 495, NSYEC1641 20, 116, 134
496
NSYDS3D43T 490, 491 NSYDS3DC44 491 NSYDS3X54 495 NSYEC165 20, 116, 134
NSYDSFX2010LH 495
NSYDS3D44 490, 499 NSYDS3DC54 491 NSYDS3X54H 495 NSYEC1651 20, 116, 134
NSYDSFX2010R 495,
NSYDS3D44T 490 NSYDS3DC55 491 NSYDS3X54T 495 NSYEC166 20, 116, 134
496
NSYDS3D46 490 NSYDS3DC64 491 NSYDS3X64 495 NSYEC1661 20, 116, 134
NSYDSFX2010RH 495
NSYDS3D46T 490 NSYDS3DC66 491 NSYDS3X64H 495 NSYEC1662 20, 116, 134
NSYDSFX2012L 495,
NSYDS3D53 490 NSYDS3DC75 491 NSYDS3X64T 495 496 NSYEC2 284
NSYDS3D53T 490 NSYDS3DC86 491 NSYDS3X66 495 NSYDSFX2012LH 495 NSYEC3 284
NSYDS3D54 490, 499 NSYDS3DC88 491 NSYDS3X66H 495 NSYDSFX2012R 495, NSYEC35 20, 116, 134
496
NSYDS3D54T 490, 491 NSYDS3DCD1010 491 NSYDS3X75 495 NSYEC351 20, 116, 134
NSYDSFX2012RH 495
NSYDS3D55 490 NSYDS3DCD106 491 NSYDS3X75H 495 NSYEC36 20, 116, 134
NSYDSFX2016L 495,
NSYDS3D55T 490 NSYDS3DCD108 491 NSYDS3X75T 495 496 NSYEC361 20, 116, 134
NSYDS3D56T 490 NSYDS3DCD1210 491 NSYDS3X86 495 NSYDSFX2016LH 495 NSYEC381 20, 116
NSYDS3D64 490, 499 NSYDS3DCD55 491 NSYDS3X86H 495 NSYDSFX2016R 495, NSYEC4 284
NSYDS3D64T 490, 491 NSYDS3DCD66 491 NSYDS3X86T 495 496 NSYEC44 20, 116, 134
NSYDS3D65 490 NSYDS3DCD75 491 NSYDS3X88 495 NSYDSFX2016RH 495 NSYEC441 20, 116, 134
NSYDS3D65T 490 NSYDS3DCD86 491 NSYDS3X88H 495 NSYDSFX206 495, 496 NSYEC45 20, 116, 134
NSYDS3D66 490, 499 NSYDS3HF108 498 NSYDSD10L 497 NSYDSFX208 495, 496 NSYEC451 20, 116, 134
NSYDS3D66T 490, 491 NSYDS3HF128 498 NSYDSD10R 497 NSYE… NSYEC461 20, 116, 134
NSYDS3D68 490 NSYDS3HF43 498 NSYDSD12L 497 NSYE1025 266 NSYEC481 20, 116, 134
NSYDS3D68T 490 NSYDS3HF46 498 NSYDSD12R 497 NSYE1525 266 NSYEC5 284
NSYDS3D75 490, 499 NSYDS3HF54 498 NSYDSD6 497 NSYE2025 266 NSYEC6 284
NSYDS3D75T 490, 491 NSYDS3HF64 498 NSYDSD8 497 NSYEB1510D6 303, 347 NSYEC64 20, 116, 134
NSYDS3D76T 490 NSYDS3HF66 498 NSYDSDF10L 497 NSYEB1516D8 303, 347 NSYEC641 20, 116, 134
NSYDS3D810 490 NSYDS3HF75 498 NSYDSDF10R 497 NSYEB156D6 303, 347 NSYEC65 20, 116, 134
NSYDS3D85L 490 NSYDS3HF86 498 NSYDSDF12L 497 NSYEB2025D8 303, 347 NSYEC651 20, 116, 134
NSYDS3D85R 490 NSYDS3X1010L 495 NSYDSDF12R 497 NSYEB2050D8 303, 347 NSYEC66 20, 116, 134
NSYDS3D86 490, 499 NSYDS3X1010LH 495 NSYDSDF16L 497 NSYEBMPLA 225 NSYEC661 20, 116, 134
NSYDS3D86L 490 NSYDS3X1010R 495 NSYDSDF16R 497 NSYEBPLA 225 NSYEC662 20, 116, 134
NSYDS3D86R 490 NSYDS3X1010RH 495 NSYDSDF8 497 NSYEC1 284 NSYEC68 20, 116, 134
NSYDS3D86T 490, 491 NSYDS3X108 495 NSYDSDX10L 498 NSYEC104 20, 116, 134 NSYEC681 20, 116, 134
NSYDS3D88 490 NSYDS3X108H 495 NSYDSDX10R 498 NSYEC1041 20, 116, 134 NSYEC682 20, 116, 134
NSYDS3D88T 490 NSYDS3X108T 495 NSYDSDX12L 498 NSYEC105 20, 116, 134 NSYEC7 284
NSYDS3DB2530 491 NSYDS3X1210L 495 NSYDSDX12R 498 NSYEC1051 20, 116, 134 NSYEC84 20, 116, 134
NSYDS3DB2540 491 NSYDS3X1210LH 495 NSYDSDX6 498 NSYEC106 20, 116, 134 NSYEC841 20, 116, 134
NSYDS3DB2550 491 NSYDS3X1210R 495 NSYDSDX8 498 NSYEC1061 20, 116, 134 NSYEC85 20, 116, 134
NSYDS3DB33 491 NSYDS3X1210RH 495 NSYDSFX1410L 495 NSYEC1062 20, 116, 134 NSYEC851 20, 116, 134
NSYDS3DB34 491 NSYDS3X128 495 NSYDSFX1410R 495 NSYEC108 20, 116, 134 NSYEC86 20, 116, 134
NSYDS3DB35 491 NSYDS3X128H 495 NSYDSFX168 495 NSYEC1081 20, 116, 134 NSYEC861 20, 116, 134
NSYDS3DB36 491 NSYDS3X32 495 NSYDSFX1812L 495, NSYEC1082 20, 116, 134 NSYEC862 20, 116, 134
496
NSYDS3DB43 491 NSYDS3X325 495 NSYEC124 20, 116, 134 NSYEC88 20, 116, 134
NSYDSFX1812LH 495
NSYDS3DB48 491 NSYDS3X325H 495 NSYEC1241 20, 116, 134 NSYEC881 20, 116, 134
NSYDSFX1812R 495,
NSYDS3DB54 491 NSYDS3X32H 495 NSYEC125 20, 116, 134 NSYEC882 20, 116, 134
496
508
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYECA22 265 NSYEX146 266 NSYFXT6040 259 NSYIN3113A1 144, 225, NSYINT91 144, 381
381
NSYECA42 265 NSYEX158 266 NSYFXT6050 259 NSYINUSA1 144, 381
NSYIN3122E1 144, 225,
NSYECA44 265 NSYEX166 266 NSYFXT6060 259, 386 381 NSYK…
NSYECB1M153 17, 51, NSYEX186 266 NSYFXT8040 259 NSYIN3123A1 144, 225, NSYKNM3 242
251, 302 381
NSYEX206 266 NSYFXT8050 259 NSYKNM6 155, 242
NSYECPC15 284 NSYIN3131A1 144, 225
NSYEX208 266 NSYFXT8060 259 NSYKPLM 26, 100, 203,
NSYECPC3 284 NSYIN3133A1 144, 225, 352
NSYEX306 266 NSYG…
NSYECPC5 284 381 NSYKSKAV 313
NSYEX308 266 NSYGB140 418
NSYECPC6 284 NSYIN3422E1 144, 225, NSYL…
NSYEX406 266 NSYGDD 490 381
NSYECPC9 284 NSYLAM14T5 295
NSYEX408 266 NSYGFR166P 267 NSYIN3432E1 144, 225,
NSYECPLAZ103 31, 219 381 NSYLAM1U 294
NSYEX506 266 NSYGFR95M55 267
NSYECPLAZ104 31, 219 NSYIN405E1 144, 225, NSYLAM75 16, 50
NSYEX508 266 NSYGFR95M63 267
NSYECPLAZ123 31, 219 381
NSYEX608 266 NSYLAM8T5 295
NSYGFR95M65 267
NSYECPLAZ124 31, 219 NSYIN421E1 144, 225,
NSYEX608 88 NSYLAMC 294
NSYGKTS6 494 381
NSYECPLAZ53 31, 219 NSYLAMC120 294
NSYF… NSYH… NSYIN4551 144, 225, 381
NSYECPLAZ54 31, 219 NSYLAMCB 294
NSYFB 241 NSYHLCR40 256 NSYIN6101 144, 225
NSYECPLAZ73 31, 219 NSYLAMCD 294
NSYFB45 251 NSYHLCR50 256 NSYINASSA2 145
NSYECPLAZ74 31, 219 NSYLAMCF 294
NSYFCESD1010 497 NSYHLCR60 256, 323 NSYINBENZ1 144, 381
NSYEDCO 251 NSYLAMCS 155
NSYFCESD108 497 NSYHLCR80 256 NSYINCW1 144, 381
NSYEDCOC 17, 51, 251 NSYLAMCS 294
NSYFCESD1210 497 NSYHS3X 495 NSYINDB31 144, 381
NSYEDCOS 17, 51, 61, NSYLAMCU 294
302 NSYFCESD128 497 NSYHSD 497 NSYINDB51 144, 225,
381 NSYLAMPORT 295
NSYEDPLA 230 NSYFCESD1610 497 NSYHSDF 497
NSYINDIN2 145, 225 NSYLC7 100, 101
NSYEL136D6 303 NSYFCESD168 497 NSYHSMX 496
NSYINE11 144, 381 NSYLC8 100, 101
NSYEL166D6 303 NSYFCESD68 497 NSYHSMXH 495
NSYINF1301 144, 225, NSYLCK12S6 494
NSYEL166D8 17, 51, 61, NSYFCESD810 497 NSYI… 381
83, 303 NSYLCK12SF 493
NSYFCESD88 497 NSYID166 19, 115, 141 NSYINF1401 144, 225,
NSYEL1710D6 303 381 NSYLCK14SF 493
NSYFCG100 286 NSYID168 19, 115, 141
NSYEL2225D8 303 NSYINFIAT1 144, 381 NSYLCK16S6 494
NSYFCG120 286 NSYID1810 19, 115, 141
NSYEL226D6 303 NSYINH31 144, 381 NSYLCK16SF 493
NSYFCG160 286 NSYID186 19, 115, 141
NSYEL2510D6 303 NSYINICHEL8131 144, NSYLCK18S6 494
NSYFCG60 286 NSYID188 19, 115, 141
NSYEL3525D8 17, 51, 381 NSYLCK18SF 493
NSYFCG80 286 NSYID2010 19, 115, 141
303 NSYINICHEL8371 144, NSYLCK20S6 494
NSYFCMX 167 NSYID206 19, 115, 141 381
NSYEMA20 265 NSYLCK20SF 493
NSYFDLSD 497 NSYID208 19, 115, 141 NSYINICHEL8791 144,
NSYEMA40 265 NSYLCK22S6 494
NSYFMPHD 310 381
NSYID226 141
NSYEMPOLN 494, 497 NSYLCK22SF 493
NSYFMPLA 219 NSYINKBA2 145
NSYID228 141
NSYEMR 15, 86, 237 NSYLCKSF 493
NSYFNM6 250, 268 NSYINKFAC2 145, 225
NSYIN1242E1 144, 225,
NSYEN20 265 NSYLCKWSF 493
NSYFNM8 250, 268 381 NSYINKJIS2 145, 225
NSYEN40 265 NSYLCR40 256
NSYFPLS1827 186 NSYIN1242E2 145, 225 NSYINKR2 145, 225
NSYEN60 265 NSYLCR50 256
NSYFPLS2727 186 NSYIN1332E1 144, 225, NSYINLCRN 15, 50, 61,
NSYETF 251 381 155, 297, 330, 333 NSYLCR60 256
NSYFPLS2736 186
NSYETU118 266 NSYIN2124E1 144, 381 NSYINS61 144, 225, 381 NSYLDB5 100, 101
NSYFPLS2754 186
NSYETU48 266 NSYIN2131A1 144, 225, NSYINS6G1 144, 381 NSYLSS3X10 495
NSYFPLS3636 186 381
NSYETU58 266 NSYINS71 144, 225, 381 NSYLSS3X12 495
NSYFPLS3654 186 NSYIN2132A1 144, 225,
NSYETU79 266 381 NSYINS81 144, 225, 381 NSYLSSDX 498
NSYFPLS3672 186
NSYEVA20 265 NSYIN2331A1 144, 225, NSYINS8G1 144, 381 NSYLSSFX14 496
NSYFPLS5454 186
NSYEVA40 265 381 NSYINS8H1 144, 381 NSYLSSFX16 496
NSYFPLS5472 186
NSYEX1006 266 NSYIN241 144, 381 NSYINT101 144, 381 NSYLSSFX18 496
NSYFSP27270 189
NSYEX1008 266 NSYIN2433A1 144, 225, NSYINT61 144, 225, 381 NSYLSSFX20 496
NSYFSP27360 189 381
NSYEX106 266 NSYINT71 144, 381 NSYLSUP 256
NSYFSP27540 189 NSYIN2452E1 144, 225,
NSYEX126 266 381 NSYINT81 144, 225, 381 NSYLT27 190
NSYFSPLAZ 223
509
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYLT8 100, 101 NSYMF106 15, 16, 50, NSYMM1010WH 16, 60, NSYMM43WH 16, 60 NSYMP168 19, 21, 22,
60, 82, 86, 155, 236 82 25, 115, 116, 118, 167,
NSYM… NSYMM44 15, 16, 24, 50,
242, 312
NSYMF108 15, 16, 24, NSYMM106 15, 16, 50, 60, 86, 155, 236, 352, 376
NSYMB106 15, 87, 236 26, 27, 50, 60, 82, 86, 155, 60, 82, 86, 155, 236, 312 NSYMP1810 19, 21, 22,
NSYMM44SB 42
NSYMB108 15, 27 236, 352 115, 116, 118, 242
NSYMM106WH 16, 60,
NSYMM44WH 16, 60
NSYMB108 87, 236 NSYMF1210 15, 16, 50, 82 NSYMP1812 19, 21, 22,
60, 82, 86, 155, 236 NSYMM45SB 42 25, 115, 116, 118, 167,
NSYMB1210 15, 87, 236 NSYMM108 15, 16, 24,
242
NSYMF126 15, 86, 236 26, 27, 50, 60, 82, 86, 155, NSYMM46SB 42
NSYMB3025 15, 27, 87, 236, 312, 352 NSYMP1816 19, 25, 115,
236 NSYMF128 15, 16, 50, NSYMM48 236 167, 242
60, 86, 155, 236 NSYMM108WH 16, 60,
NSYMB32 15, 27, 87, 236 82 NSYMM48SB 42 NSYMP186 19, 21, 22,
NSYMF2PLAZ4 307, 310
NSYMB33 15, 87, 236 NSYMM53 236 25, 115, 116, 118, 167,
NSYMM11SB 42
NSYMF2PLAZ6 307, 310 242
NSYMB43 15, 27, 87, 236 NSYMM1210 15, 16, 24, NSYMM54 15, 16, 24, 26,
NSYMF32 15, 16, 24, 50, 27, 50, 60, 86, 155, 236, NSYMP188 19, 21, 22,
NSYMB54 15, 27, 87, 236 50, 60, 82, 86, 155, 236
60, 86, 55, 236 312, 352 25, 115, 116, 118, 167,
NSYMM1210WH 16 242
NSYMB64 15, 27, 87, 236 NSYMF33 15, 16, 50, 60, NSYMM54WH 16, 60
82, 86, 155, 236, 352 NSYMM1210WH 60, 82 NSYMP2010 19, 21, 23,
NSYMB65 15, 87, 236 NSYMM55 15, 16, 50, 60, 25, 115, 116, 119, 167,
NSYMB75 15, 27, 87, 236 NSYMF43 15, 16, 24, 26, NSYMM1212 15, 86, 236 82, 86, 236 242
27, 50, 60, 86, 155, 236,
NSYMB86 15, 27, 87, 236 352 NSYMM126 15, 86, 236 NSYMM55WH 16, 60, 82 NSYMP2012 19, 21, 23,
NSYMM128 24 NSYMM64 15, 16, 24, 26, 25, 115, 116, 119, 167,
NSYMCCSD4 497 NSYMF44 15, 16, 50, 60,
27, 50, 60, 86, 155, 236, 242
86, 155, 236, 352, 376 NSYMM128 15, 16, 24,
NSYMCCSD6 497 312, 313, 352, 376
50, 60, 86, 155, 236 NSYMP2016 19, 21, 23,
NSYMF53 236 25, 115, 116, 119, 167,
NSYMCSX 166 NSYMM64WH 16, 60
NSYMF54 15, 16, 24, 26, NSYMM128WH 16, 60 242
NSYMD108 15, 24, 87, NSYMM65 15, 86, 236
27, 50, 60, 86, 155, 236, NSYMM12SB 42 NSYMP206 19, 21, 23,
236, 352
352 NSYMM66 15, 16, 24, 50, 25, 115, 116, 119, 167,
NSYMD128 15, 87, 236 NSYMM13SB 42
NSYMF55 15, 16, 50, 60, 60, 82, 86, 155, 236, 312, 242
NSYMD33 15, 87, 236, 82, 86, 155, 236 NSYMM1410 15, 86, 236 352
NSYMP208 19, 21, 23,
352 NSYMM14SB 42 NSYMM66WH 16, 60, 82 25, 115, 116, 119, 167,
NSYMF64 15, 16, 24, 26,
NSYMD43 15, 24, 87, 27, 50, 60, 86, 155, 236, 242, 312, 323
NSYMM22 15, 86, 236 NSYMM75 15, 16, 24, 26,
236, 352 352, 376 27, 50, 60, 82, 86, 155, NSYMP2210 116, 119
NSYMM22SB 42 236, 312, 352,
NSYMD54 15, 24, 87, NSYMF65 15, 86, 236 NSYMP2210 21, 23, 242
236, 352 NSYMM23 236 NSYMM75WH 16, 60, 82
NSYMF66 15, 16, 50, 60, NSYMP2212 21, 23, 116,
NSYMD64 15, 24, 87, 82, 86, 155, 236, 352 NSYMM23SB 42 NSYMM76 236 119, 242
236, 352 NSYMM24SB 42
NSYMF75 15, 16, 24, 26, NSYMM86 15, 16, 24, 26, NSYMP226 21, 23, 116,
NSYMD66 15, 87, 236, 27 27, 50, 60, 82, 86, 155, 119, 242
NSYMM2520 15, 86, 236
352 236, 312, 352
NSYMF75 50, 60, 82, 86, NSYMP228 21, 23, 116,
NSYMM2540 236
NSYMD75 15, 24, 87, 155, 236, 352 NSYMM86WH 16, 60, 82 119, 242
236, 352 NSYMM2550 236
NSYMF86 15, 16, 24, 26, NSYMM88 15, 16, 24, NSYMPB4SD 383
NSYMD86 15, 24, 87, 27, 50, 60, 82, 86, 155, NSYMM25SB 42 155, 236, 312, 50, 60, 86
236, 352 236, 352 NSYMPB6SD 383
NSYMM26SB 42 NSYMM88WH 16, 60
NSYMDCM20 143, 297 NSYMF88 15, 16, 50, 60, NSYMPBSD 383
NSYMM28SB 42 NSYMP1210 19, 115, 242
86, 155, 236
NSYMDVR10 16, 50, 60, NSYMPFA 326
NSYMM3025 15, 24, 26, NSYMP1212 19, 115,
82, 87, 241 NSYMFB 250, 268
27, 86, 155, 236, 352 242, 312 NSYMPP108 27, 236
NSYMDVR12 16, 50, 60, NSYMFPLAZ103 31, 222
NSYMM3045 15, 86, 236 NSYMP126 21, 22, 116, NSYMPP3025 27, 236
82, 87, 241
NSYMFPLAZ104 31, 222 118, 242, 312
NSYMM32 15, 16, 24, 27, NSYMPP32 27, 236
NSYMDVR3 16, 50, 60,
NSYMFPLAZ123 31, 222 50, 60, 86, 155, 236, 312, NSYMP128 19, 21, 22,
87, 241 NSYMPP43 27, 236
352 115, 116, 118, 242, 312
NSYMFPLAZ124 31, 222
NSYMDVR3M 241 NSYMPP54 27, 236
NSYMM32WH 16, 60 NSYMP1410 19, 25, 115,
NSYMFPLAZ53 31, 222
NSYMDVR4 16, 50, 60, 167, 242, 382 NSYMPP64 27, 236
NSYMM33 15, 16, 24, 50,
87, 241 NSYMFPLAZ54 31, 222
60, 86, 155, 236, 352, NSYMP1412 19, 115, NSYMPP75 27, 236
NSYMDVR5 16, 50, 60, NSYMFPLAZ73 31, 222 242, 382
NSYMM33SB 42 NSYMPP86 27, 236
82, 87, 241
NSYMFPLAZ74 31, 222 NSYMP146 19, 21, 22,
NSYMM33WH 16, 60 NSYMPRK10 243
NSYMDVR6 16, 50, 60, 115, 116, 118, 242
82, 87, 241 NSYML23 386
NSYMM34SB 42 NSYMPRK12 243
NSYMP148 19, 21, 22,
NSYMDVR7 16, 50, 60, NSYML405SD 380
NSYMM35SB 42 115, 116, 118, 242, 382 NSYMPRK16 243
82, 87, 241 NSYMLCD23 386
NSYMM36 236 NSYMP1610 19, 115, 242 NSYMPRK8 243
NSYMDVR8 16, 50, 60, NSYMLS6 386
82, 87, 241 NSYMM36SB 42 NSYMP1612 19, 115, NSYMR1010 15, 16, 50,
NSYMLT6 386 242, 312 60, 82, 87, 155, 236,
NSYMF1010 15, 16, 50, NSYMM38SB 42
60, 82, 86, 155, 236 NSYMM1010 15, 16, 24, NSYMP166 19, 21, 22, NSYMR1012 15, 87, 236
NSYMM43 15, 16, 24, 26,
50, 60, 82, 86, 155, 236 115, 116, 118, 242, 312
27, 50, 60, 86, 155, 236,
352
510
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYMR106 15, 16, 50, NSYMS75 15, 24, 26, 27, NSYPAS3CM86 498 NSYPHDZT15124 310, NSYPLA10124 28, 214
60, 82, 87, 155, 236 86, 155, 236, 352 317
NSYPC100 493 NSYPLA10124T 28, 214
NSYMR108 15, 16, 24, NSYMS86 15, 24, 26, 27, NSYPHDZT15124P 310,
NSYPC200 493 NSYPLA1053 28, 214
26, 27, 50, 60, 82, 87, 155, 86, 155, 236, 352 317
236, 352 NSYPCS10 383 NSYPLA1053T 28, 214
NSYMUPLA103 218 NSYPHDZT15126 310,
NSYMR1210 15, 16, 50, NSYPCS12 383 317 NSYPLA1054 28, 214
NSYMUPLA104 218
60, 82, 87, 155, 236
NSYPCS16 383 NSYPHDZT15126P 310, NSYPLA1054T 28, 214
NSYMUPLA123 218
NSYMR126 15, 87, 236 317
NSYPCS8 383 NSYPLA1073 28, 214
NSYMUPLA124 218
NSYMR128 15, 16, 50, NSYPHDZT1574 310,
60, 87, 155, 236 NSYPCVR124HD 310, 317 NSYPLA1073T 28, 214
NSYMUPLA126 218
317
NSYMR1410 15, 87, 236 NSYPHDZT1574P 310, NSYPLA1074 28, 214
NSYMUPLA153 218
NSYPCVR126HD 310, 317
NSYMR3025 15, 26, 27, NSYPLA1074T 28, 214
NSYMUPLA154 218 317
155, 236, 352, 87 NSYPHDZT1576 310, NSYPLA12103 28, 214
NSYMUPLA156 218 NSYPCVR54HD 310, 317 317
NSYMR32 16, 24, 27, 50, NSYPLA12103T 28, 214
60, 155, 236, 352 NSYMUPLA53 218 NSYPCVR74HD 310, 317 NSYPHDZT1576P 310,
317 NSYPLA12104 28, 214
NSYMR33 15, 16, 50, 60, NSYMUPLA54 218 NSYPCVR76HD 310, 317
87, 155, 236, 352 NSYPHDZT2074 310, NSYPLA12104T 28, 214
NSYMUPLA73 218 NSYPF27N 189
317 NSYPLA12123 28, 214
NSYMR34 15, 87, 236 NSYMUPLA74 218 NSYPF27X 189
NSYPHDZT2074P 310, NSYPLA12123T 28, 214
NSYMR43 15, 16, 24, 26, NSYMUPLA76 218 NSYPFC2X 94, 156, 352 317
27, 50, 60, 87, 155, 236, NSYPLA12124 28, 214
352 NSYMW10M 300 NSYPFCR 88, 94, 343 NSYPHDZT774 310, 317
NSYPLA12124T 28, 214
NSYMR44 15, 16, 50, 60, NSYMW10MK 300 NSYPFCX 16, 50, 156, NSYPHDZT774P 310,
87, 155, 236, 376 352 317 NSYPLA1253 28, 214
NSYMW10MR 301
NSYMR46 15, 87, 155, NSYPFPLM 16, 27, 50, NSYPHDZT776 310, 317 NSYPLA1253T 28, 214
NSYN… 200
236
NSYPHDZT776P 310, NSYPLA1254 28, 214
NSYNM4 241, 268 NSYPFPLM32 27, 200
NSYMR53 236 317
NSYPLA1254T 28, 214
NSYNM5 241, 268 NSYPFXPLM 200, 352,
NSYMR54 15, 16, 24, 26, NSYPHX200 167, 296
353 NSYPLA1273 28, 214
27, 50, 60, 87, 155, 236, NSYNM6 16, 50, 241, 268
NSYPHX200 388, 389
352 NSYPHDT553 310, 317 NSYPLA1273T 28, 214
NSYO… NSYPIN106 60, 88, 104
NSYMR55 15, 16, 50, 60, NSYPHDT553P 310, 317 NSYPLA1274 28, 214
82, 87, 236 NSYOL6GF 133 NSYPIN108 60, 88, 104,
NSYPHDT753 310, 317 NSYPLA1274T 28, 214
NSYP… 157
NSYMR64 15, 16, 24, 26,
27, 50, 60, 87, 155, 236, NSYPHDT753P 310, 317 NSYPLA15103 28, 214
NSYPA3025PLM 27, 201 NSYPIN126 88, 104
352, 376 NSYPLA15103T 28, 214
NSYPHDZT1054 310, NSYPIN128 60, 88, 104,
NSYPAP108 27, 201
NSYMR65 15, 87, 236 317 157 NSYPLA15104 28, 214
NSYPAP43 27, 201
NSYMR66 15, 16, 50, 60, NSYPHDZT1054P 310, NSYPIN43 60, 88, 104, NSYPLA15104T 28, 214
82, 87, 155, 236, 352 NSYPAP54 27, 201 317 157
NSYPLA15123 28, 214
NSYMR68 15, 87, 236 NSYPAP64 27, 201 NSYPHDZT1074 310, NSYPIN54 60, 88, 104,
317 157 NSYPLA15123T 28, 214
NSYMR75 15, 16, 24, 26, NSYPAP75 27, 201
27, 50, 60, 82, 87, 155, NSYPHDZT1074P 310, NSYPIN64 60, 88, 104, NSYPLA15124 28, 214
NSYPAP86 27, 201 317
236, 352 157 NSYPLA15124T 28, 214
NSYPAPLA105 30, 224 NSYPHDZT12124 310,
NSYMR76 236 NSYPIN75 60, 88, 104, NSYPLA1553 28, 214
NSYPAPLA107 30, 224 317 157
NSYMR810 15, 87, 236 NSYPLA1553T 28, 214
NSYPAPLA125 30, 224 NSYPHDZT12124P 310, NSYPIN86 60, 88, 104,
NSYMR86 15, 16, 24, 26, 317 NSYPLA1554 28, 214
157
27, 50, 60, 82, 87, 155, NSYPAPLA127 30, 224
236, 352 NSYPHDZT12126 310, NSYPLA(T)●103 220 NSYPLA1554T 28, 214
NSYPAPLA155 30, 224 317
NSYMR88 15, 16, 50, 60, NSYPLA(T)●104 220 NSYPLA1573 28, 214
87, 155, 236 NSYPAPLA157 30, 224 NSYPHDZT12126P 310,
NSYPLA(T)●123 220 NSYPLA1573T 28, 214
NSYPAPLA55 30, 224 317
NSYMS43 15, 24, 26, 27, NSYPLA1574 28, 214
86, 155, 236, 352 NSYPHDZT1254 310, NSYPLA(T)●124 220
NSYPAPLA57 30, 224
317 NSYPLA(T)●53 220 NSYPLA1574T 28, 214
NSYMS44 15, 86, 155, NSYPAPLA75 30, 224
236, 352 NSYPHDZT1254P 310, NSYPLA(T)●54 220 NSYPLA5103 28, 214
NSYPAPLA77 30, 224 317
NSYMS46 27, 352 NSYPLA(T)●73 220 NSYPLA5103T 28, 214
NSYPAS3CM33 498 NSYPHDZT1274 310,
NSYMS53 236 317 NSYPLA(T)●74 220 NSYPLA5104 28, 214
NSYPAS3CM34 498
NSYMS54 15, 24, 26, 27, NSYPHDZT1274P 310, NSYPLA10103 28, 214 NSYPLA5104T 28, 214
86, 155, 236, 352 NSYPAS3CM44 498
317 NSYPLA5123 28, 214
NSYPLA10103T 28, 214
NSYMS55 15, 86, 236 NSYPAS3CM46 498
NSYPHDZT1276 310, NSYPLA5123T 28, 214
NSYPLA10104 28, 214
NSYMS64 15, 24, 26, 27, NSYPAS3CM55 498 317
NSYPLA10104T 28, 214 NSYPLA5124 28, 214
86, 155, 236, 352 NSYPAS3CM66 498 NSYPHDZT1276P 310,
317 NSYPLA10123 28, 214 NSYPLA5124T 28, 214
NSYMS66 15, 86, 155, NSYPAS3CM68 498
236, 352 NSYPLA10123T 28, 214 NSYPLA553 28, 214
511
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYPLA553T 28, 214 NSYPLAT553 29, 215 NSYPLAZ774 28, 214 NSYPLM●●V 203 NSYPLM75T 26, 195,
196, 206
NSYPLA554 28, 214 NSYPLAT554 29, 215 NSYPLAZT10103 29, NSYPLM108 16, 26, 50,
215 195, 196, 199, 206 NSYPLM75TV 26, 195,
NSYPLA554T 28, 214 NSYPLAT573 29, 215
196
NSYPLAZT10104 29, NSYPLM108B 195
NSYPLA573 28, 214 NSYPLAT574 29, 215 215 NSYPLM75V 26, 195
NSYPLM108G 199, 200
NSYPLA573T 28, 214 NSYPLAT7103 29, 215 NSYPLAZT10123 29, NSYPLM86 16, 26, 50,
215 NSYPLM108G/TG 203
NSYPLA574 28, 214 NSYPLAT7104 29, 215 195, 196, 199, 206
NSYPLAZT10124 29, NSYPLM108T 26, 195,
NSYPLA574T 28, 214 NSYPLAT7123 29, 215 NSYPLM86B 195
215 196, 206
NSYPLA7103 28, 214 NSYPLAT7124 29, 215 NSYPLM86G 199
NSYPLAZT1053 29, 215 NSYPLM3025 26, 195
NSYPLA7103T 28, 214 NSYPLAT753 29, 215 NSYPLM86P 195
NSYPLAZT1054 29, 215 NSYPLM3025B 195
NSYPLA7104 28, 214 NSYPLAT754 29, 215 NSYPLM86T 26, 195,
NSYPLAZT1073 29, 215 NSYPLM3025G 201
196, 206
NSYPLA7104T 28, 214 NSYPLAT773 29, 215
NSYPLAZT1074 29, 215 NSYPLM3025G/TG 207
NSYPLM86TV 26, 195,
NSYPLA7123 28, 214 NSYPLAT774 29, 215 196
NSYPLAZT12103 29, NSYPLM3025P 195
NSYPLA7123T 28, 214 NSYPLAZ10103 28, 214 215 NSYPLM86V 26, 195
NSYPLM3025T 26, 195
NSYPLA7124 28, 214 NSYPLAZ10104 28, 214 NSYPLAZT12104 29, NSYPLMEX108 26, 352,
NSYPLM32 16, 26, 50,
NSYPLA7124T 28, 214 NSYPLAZ10123 28, 214 215 195, 200 353, 355
NSYPLA753 28, 214 NSYPLAZ10124 28, 214 NSYPLAZT12123 29, NSYPLM32B 195 NSYPLMEX3025 26, 352,
215 353
NSYPLA753T 28, 214 NSYPLAZ1053 28, 214 NSYPLM32P 195
NSYPLAZT12124 29, NSYPLMEX43 26, 352,
NSYPLA754 28, 214 NSYPLAZ1054 28, 214 215 NSYPLM32T 26, 195, 355
200
NSYPLA754T 28, 214 NSYPLAZ1073 28, 214 NSYPLAZT1253 29, 215 NSYPLMEX54 26, 352,
NSYPLM43 16, 26, 50, 355
NSYPLA773 28, 214 NSYPLAZ1074 28, 214 NSYPLAZT1254 29, 215 195, 196, 206
NSYPLA773T 28, 214 NSYPLAZ12103 28, 214 NSYPLMEX64 26, 352,
NSYPLAZT1273 29, 215 NSYPLM43B 195 355
NSYPLA774 28, 214 NSYPLAZ12104 28, 214 NSYPLAZT1274 29, 215 NSYPLM43P 195 NSYPLMEX75 26, 352,
NSYPLA774T 28, 214 NSYPLAZ12123 28, 214 NSYPLAZT15103 29, NSYPLM43T 26, 195, 355
NSYPLAT10103 29, 215 215 196, 206
NSYPLAZ12124 28, 214 NSYPLMEX86 26, 352,
NSYPLAT10104 29, 215 NSYPLAZT15104 29, NSYPLM43TV 26, 195, 355
NSYPLAZ1253 28, 214
215 196
NSYPLAT10123 29, 215 NSYPLS●●● 190
NSYPLAZ1254 28, 214
NSYPLAZT15123 29, NSYPLM43V 26, 195
NSYPLAT10124 29, 215 NSYPLS●●●DLS●●● 190
NSYPLAZ1273 28, 214 215
NSYPLM54 16, 26, 50, NSYPLS1827 13, 186
NSYPLAT1053 29, 215 NSYPLAZ1274 28, 214 NSYPLAZT15124 29, 195, 196, 206
215 NSYPLS1827 186
NSYPLAT1054 29, 215 NSYPLAZ15103 28, 214 NSYPLM54B 195
NSYPLAZT1553 29, 215 NSYPLS1827DLS12 186
NSYPLAT1073 29, 215 NSYPLAZ15104 28, 214 NSYPLM54G 200
NSYPLAZT1554 29, 215 NSYPLS1827L 13, 186
NSYPLAT1074 29, 215 NSYPLAZ15123 28, 214 NSYPLM54P 195
NSYPLAZT1573 29, 215 NSYPLS24 379
NSYPLAT12103 29, 215 NSYPLAZ15124 28, 214 NSYPLM54T 26, 195,
NSYPLAZT1574 29, 215 196, 206 NSYPLS2727 13, 186
NSYPLAT12104 29, 215 NSYPLAZ1553 28, 214
NSYPLAZT5103 29, 215 NSYPLM54TG 200 NSYPLS2727A 13, 186
NSYPLAT12123 29, 215 NSYPLAZ1554 28, 214
NSYPLAZT5104 29, 215 NSYPLM54TV 26, 195, NSYPLS2727AL 13, 186
NSYPLAT12124 29, 215 NSYPLAZ1573 28, 214
NSYPLAZT5123 29, 215 196
NSYPLAT1253 29, 215 NSYPLS2727DLS24 186
NSYPLAZ1574 28, 214
NSYPLAZT5124 29, 215 NSYPLM54V 26, 195
NSYPLAT1254 29, 215 NSYPLS2727L 13, 186
NSYPLAZ5103 28, 214
NSYPLAZT553 29, 215 NSYPLM64 16, 26, 50,
NSYPLAT1273 29, 215 NSYPLS2736 13, 186
NSYPLAZ5104 28, 214 195, 196, 206
NSYPLAZT554 29, 215 NSYPLS2736A 13, 186
NSYPLAT1274 29, 215 NSYPLAZ5123 28, 214 NSYPLM64B 195
NSYPLAZT573 29, 215 NSYPLS2736AL 13, 186
NSYPLAT15103 29, 215 NSYPLAZ5124 28, 214 NSYPLM64G 200
NSYPLAZT574 29, 215 NSYPLS2736L 13, 186
NSYPLAT15104 29, 215 NSYPLAZ553 28, 214 NSYPLM64P 195
NSYPLAZT7103 29, 215 NSYPLS2754 13, 186
NSYPLAT15123 29, 215 NSYPLAZ554 28, 214 NSYPLM64T 26, 195,
NSYPLAZT7104 29, 215 196, 206 NSYPLS2754A 13, 186
NSYPLAT15124 29, 215 NSYPLAZ573 28, 214
NSYPLAZT7123 29, 215 NSYPLM64TG 200 NSYPLS2754AL 13, 186
NSYPLAT1553 29, 215 NSYPLAZ574 28, 214
NSYPLAZT7124 29, 215 NSYPLM64TV 26, 195, NSYPLS2754L 13, 186
NSYPLAT1554 29, 215 NSYPLAZ7103 28, 214
196
NSYPLAZT753 29, 215 NSYPLS30 379
NSYPLAT1573 29, 215 NSYPLAZ7104 28, 214
NSYPLM64V 26, 195
NSYPLAZT754 29, 215 NSYPLS3627DLS24 186
NSYPLAT1574 29, 215 NSYPLAZ7123 28, 214
NSYPLM75 26, 195, 196,
NSYPLAZT773 29, 215 NSYPLS3627DLS36 186
NSYPLAT5103 29, 215 NSYPLAZ7124 28, 214 199, 206
NSYPLAZT774 29, 215 NSYPLS3636 13, 186
NSYPLAT5104 29, 215 NSYPLAZ753 28, 214 NSYPLM75B 195
NSYPLD114P 30 NSYPLS3636L 13, 186
NSYPLAT5123 29, 215 NSYPLAZ754 28, 214 NSYPLM75G 199
NSYPLHD 310 NSYPLS3654 13, 186
NSYPLAT5124 29, 215 NSYPLAZ773 28, 214 NSYPLM75P 195
512
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYPLS3654A 13, 186 NSYPMA5472 186 NSYPMM1010 30, 226 NSYPMP85120 25, 382 NSYPTZ6 230
NSYPLS3654AL 13, 186 NSYPMA55 30, 226 NSYPMM1012 30, 226 NSYPMP85160 382 NSYPTZ62P 230
NSYPLS3654L 13, 186 NSYPMA710 30, 226 NSYPMM105 30, 226, NSYPMP8560 25, 382 NSYPUC27 191
310
NSYPLS3672A 13, 186 NSYPMA712 30, 226 NSYPMP8580 25, 382 NSYPUNX 167
NSYPMM107 30, 226,
NSYPLS3672AL 13, 186 NSYPMA75 30, 226 310
NSYPMR105 30, 226 NSYR…
NSYPLS5427DLS48 186, NSYPMA77 30, 226 NSYPMR107 30, 226 NSYRCK42 323
NSYPMM1210 30, 226
191
NSYPMB1010 30, 226 NSYPMR125 30, 226 NSYRE26 138, 420
NSYPMM1212 30, 226,
NSYPLS5454 13, 186
NSYPMB1012 30, 226 310 NSYPMR127 30, 226 NSYRE60 138, 420
NSYPLS5454A 13, 186
NSYPMB105 30, 226 NSYPMM125 30, 226, NSYPMR155 30, 226 NSYRETPLA 224
NSYPLS5454AL 13, 186 310
NSYPMB107 30, 226 NSYPMR157 30, 226 NSYRETPLAU 224, 228,
NSYPLS5454L 13, 186 NSYPMM127 30, 226, 230
NSYPMB1210 30, 226 310 NSYPMR1827 186
NSYPLS5472A 13, 186 NSYRP2 376, 377
NSYPMB1212 30, 226 NSYPMM1510 30, 226 NSYPMR2727 186
NSYPLS5472AL 13, 186 NSYRPX2 376, 377
NSYPMB125 30, 226 NSYPMM1512 30, 226, NSYPMR2736 186
NSYPLSC1827 13, 186 310 NSYRSF104 493
NSYPMB127 30, 226 NSYPMR2754 186
NSYPLSC2727 13, 186 NSYPMM155 30, 226 NSYRSF105 493
NSYPMB1510 30, 226 NSYPMR3654 186
NSYPLSC2727A 13, 186 NSYPMM157 30, 226, NSYRSF106 493
NSYPMB1512 30, 226 NSYPMR3672 186
NSYPLSC2736 13, 186 310 NSYRSF108 493
NSYPMB155 30, 226 NSYPMR5454 186
NSYPLSC2736A 13, 186 NSYPMM1827 186 NSYRSF124 493
NSYPMB157 30, 226 NSYPMR5472 186
NSYPLSC2754 13, 186 NSYPMM207 310 NSYRSF125 493
NSYPMB1827 186 NSYPMR55 30, 226
NSYPLSC2754A 13, 186 NSYPMM2727 186 NSYRSF126 493
NSYPMB2727 186 NSYPMR57 30, 226
NSYPLSC3636 13, 186 NSYPMM2736 186 NSYRSF128 493
NSYPMB2736 186 NSYPMR75 30, 226
NSYPLSC3654 13, 186 NSYPMM2754 186 NSYRSF164 493
NSYPMB2754 186 NSYPMR77 30, 226
NSYPLSC3654A 13, 186 NSYPMM3636 186 NSYRSF165 493
NSYPMB3636 186 NSYPPC54HD 499
NSYPLSC3672A 13, 186 NSYPMM3654 186 NSYRSF166 493
NSYPMB3654 186 NSYPPC56HD 499
NSYPLSC5454 13, 186 NSYPMM3672 186 NSYRSF35 493
NSYPMB3672 186 NSYPPC74HD 499
NSYPLSC5454A 13, 186 NSYPMM510 30, 226 NSYRSF36 493
NSYPMB510 30, 226 NSYPPC76HD 499
NSYPLSC5472A 13, 186 NSYPMM5454 186 NSYRSF38 493
NSYPMB5454 186 NSYPPS●●● 326
NSYPLSP1827 13, 186 NSYPMM5472 186 NSYRSF44 493
NSYPMB5472 186 NSYPPS166 124
NSYPLSP2727 13, 186 NSYPMM55 30, 226, 310 NSYRSF45 493
NSYPMB55 30, 226 NSYPPS168 124
NSYPLSP2736 13, 186 NSYPMM710 30, 226 NSYRSF64 493
NSYPMB710 30, 226 NSYPPS184 124
NSYPLSP2754 13, 186 NSYPMM712 30, 226 NSYRSF65 493
NSYPMB712 30, 226 NSYPPS185 124
NSYPLSP3636 13, 186 NSYPMM75 30, 226, 310 NSYRSF66 493
NSYPMB75 30, 226 NSYPPS186 124
NSYPLSP3654 13, 186 NSYPMM77 30, 226, 310 NSYRSF84 493
NSYPMB77 30, 226 NSYPPS204 124
NSYPLSP5454 13, 186 NSYPMP300DLM 88 NSYRSF85 493
NSYPMD1510 12, 34 NSYPPS205 124
NSYPMA1010 30, 226 NSYPMP400DLA 207 NSYRSF86 493
NSYPMD2015 12, 34, 35 NSYPPS206 124
NSYPMA1012 30, 226 NSYPMP400DLM 88 NSYRSF88 493
NSYPMD2520 12, 34, 35 NSYPPS208 124
NSYPMA105 30, 226 NSYPMP45100 382 NSYRSW27 19, 115
NSYPMD3025 12, 34, 35 NSYPPS226 124
NSYPMA107 30, 226 NSYPMP45120 382 NSYRSW31 19, 115
NSYPMD3530 12, 34, 35 NSYPPS228 124
NSYPMA1210 30, 226 NSYPMP45160 382 NSYRSW36 19, 115
NSYPMLA103 226 NSYPPS27 190
NSYPMA1212 30, 226 NSYPMP4580 382 NSYRSW40 19, 115
NSYPMLA104 226 NSYPPSB 45
NSYPMA125 30, 226 NSYPMP5002DLP 232 NSYRSWC27 19, 115
NSYPMLA123 226 NSYPS2C27 189, 191
NSYPMA127 30, 226 NSYPMP500DLA 207 NSYRSWC31 19, 115
NSYPMLA124 226 NSYPS4C27 189, 191
NSYPMA1827 186 NSYPMP500DLM 88 NSYRSWC36 19, 115
NSYPMLA126 226 NSYPTDS1 391, 393
NSYPMA2727 186 NSYPMP500DLP 232 NSYRSWC40 19, 115
NSYPMLA153 226 NSYPTDS2 391, 393
NSYPMA2736 186 NSYPMP600DLA 207
NSYPMLA154 226 NSYPTDS3 391, 393 NSYS…
NSYPMA2754 186 NSYPMP600DLM 88
NSYPMLA156 226 NSYPTDS4 391 NSYS12M6H 16, 50
NSYPMA3636 186 NSYPMP7502DLP 232
NSYPMLA53 226 NSYPTDS5 391 NSYS13M5HS 16, 50, 61,
NSYPMA3654 186 NSYPMP750DLP 232 83, 155, 268
NSYPMLA54 226 NSYPTZ3 230
NSYPMA3672 186 NSYPMP800DLA 207 NSYS16M5HS 155, 245,
NSYPMLA73 226 NSYPTZ32P 230 268
NSYPMA510 30, 226 NSYPMP800DLM 88
NSYPMLA74 226 NSYPTZ4 230 NSYS16M6H 16, 50
NSYPMA5454 186 NSYPMP85100 25, 382
NSYPMLA76 226 NSYPTZ42P 230 NSYS16M6HS 155, 268
513
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYS18M6H 16, 50 NSYS3DC5520 16, 50, NSYS3HD4320 312 NSYS3X5420H 16, 24, NSYSBM154012 12, 42,
60, 77 50, 153 45
NSYS3CM303020 360, NSYS3HD5420 312
361, 366 NSYS3DC5525 16, 50, NSYS3X5420T 24, 153 NSYSBM15408 12, 42,
NSYS3HD6425 312
60, 77 45
NSYS3CM304020 360, NSYS3X601030 24, 153
NSYS3HD6630 312
361, 366 NSYS3DC6420 16, 50, NSYSBM202012 12, 42,
60, 77 NSYS3X601230 24, 153 45
NSYS3HD7525 312
NSYS3CM404020 360,
361, 366 NSYS3DC6425 16, 50, NSYS3X6420 16, 24, 50, NSYSBM20208 12, 42,
NSYS3HD8630 312, 317
60, 77 153 45
NSYS3CM406025 360, NSYS3HD8840 312, 317
361, 366 NSYS3DC6620 16, 50, NSYS3X6420H 16, 24, NSYSBM203012 12, 42,
60, 77 NSYS3HF10830P 343 50, 153 45
NSYS3CM505025 360,
361, 366 NSYS3DC6625 16, 50, NSYS3HF12830P 343 NSYS3X6420T 24, 153 NSYSBM20308 12, 42,
60, 77 NSYS3HF4320P 343 NSYS3X6625 16, 24, 50, 45
NSYS3CM606020 360,
361, 366 NSYS3DC6630 16, 50, 153 NSYSBM204012 12, 42,
NSYS3HF4620P 343
60, 77 NSYS3X6625H 16, 24, 45
NSYS3CM608030 360, NSYS3HF5420P 343
361, 366 NSYS3DC7525 16, 50, 50, 153 NSYSBM20408 12, 42,
60, 77 NSYS3HF6420P 343 NSYS3X7525 16, 24, 50, 45
NSYS3CM806030 360,
361, 366 NSYS3DC8620 16, 50, NSYS3HF6625P 343 153 NSYSBM205012 12, 42,
60, 77 NSYS3HF7525P 343 NSYS3X7525H 16, 24, 45
NSYS3CVR64HD 312,
317 NSYS3DC8625 16, 50, 50, 153 NSYSBM20508 12, 42,
NSYS3HF8630P 343
60, 77 NSYS3X7525T 24, 153 45
NSYS3CVR84HD 312, NSYS3X101030 24, 153
317 NSYS3DC8630 16, 50, NSYS3X801030 24, 153 NSYSBM206012 12, 42,
60, 77 NSYS3X101030H 24, 153 45
NSYS3D10625 16, 50 NSYS3X801230 24, 153
NSYS3DC8640 16, 50, NSYS3X10830 16, 24, NSYSBM20608 12, 42,
NSYS3D12840PK3 332 50, 153 NSYS3X8625 16, 24, 50,
60, 77 45
NSYS3D32515PK3 332 153
NSYS3DC8825 16, 50, NSYS3X10830H 16, 24, NSYSBM208012 12, 42,
NSYS3D4320PK3 332 60, 77 50, 153 NSYS3X8625H 16, 24, 45
50, 153
NSYS3D6525PK3 332 NSYS3DC8830 16, 50, NSYS3X10830T 24, 153 NSYSBM303012 12, 42,
60, 77 NSYS3X8625T 24, 153 45
NSYS3D7525PK3 332 NSYS3X121030 24, 153
NSYS3DCD101030 82 NSYS3X8830 16, 24, 50, NSYSBM304012 12, 42,
NSYS3D8630PK3 332 NSYS3X121030H 24, 153 153 45
NSYS3DCD10620 82
NSYS3DC101030 16, 50, NSYS3X12830 16, 24, NSYS3X8830H 16, 24, NSYSBM305012 12, 42,
60, 77 NSYS3DCD10820 82 50, 153 50, 153 45
NSYS3DC10625 60, 77 NSYS3DCD121030 82 NSYS3X12830H 16, 24, NSYS3XEX10830 24, NSYSBM306012 12, 42,
50, 153 352
NSYS3DC10825 16, 50, NSYS3DCD5520 82 45
60, 77 NSYS3X302515 24, 153 NSYS3XEX3215 24, 352
NSYS3DCD6620 82 NSYSBM308012 12, 42,
NSYS3DC10830 16, 50, NSYS3X302515H 24, 153 NSYS3XEX4320 24, 352 45
NSYS3DCD7520 82
60, 77 NSYS3X3215 16, 24, 50, NSYSBM404012 12, 42,
NSYS3DCD8620 82 NSYS3XEX5420 24, 352
NSYS3DC10840 16, 50, 153 45
60, 77 NSYS3DCGPSTDSB NSYS3XEX6420 24, 352
NSYS3X3215H 16, 24, NSYSBM405012 12, 42,
490, 491, 492, 499 50, 153 NSYS3XEX7525 24, 352 45
NSYS3DC121030 16, 50,
60, 77 NSYS3DCGSB 490, 491, NSYS3X3315 16, 24, 50, NSYS3XEX8625 24, 352 NSYSBM406012 12, 42,
492, 499 153 45
NSYS3DC12830 16, 50, NSYS5GPC35 325
60, 77 NSYS3DEX10830 352 NSYS3X3315H 16, 24, NSYSBM408012 12, 42,
NSYS5GPC38 325
NSYS3DC12840 16, 50, NSYS3DEX3215 352 50, 153 45
60, 77 NSYS5GPC75 325
NSYS3DEX3320 352 NSYS3X4315 16, 24, 50, NSYSBMB203012 12,
NSYS3DC3215 16, 50, 153 NSYS5GPC78 325 42, 45
NSYS3DEX4320 352
60, 77 NSYS3X4315H 16, 24, NSYS5GPC86 323 NSYSBMB204012 12,
NSYS3DEX4420 352 50, 153 42, 45
NSYS3DC3315 16, 50, NSYSB130 241
60, 77 NSYS3DEX5420 352 NSYS3X4320 16, 24, 50, NSYSBMB206012 12,
NSYSB90 241
NSYS3DC3320 16, 50, NSYS3DEX6425 352 153 42, 45
60, 77 NSYSBM151512 12, 42,
NSYS3DEX6625 352 NSYS3X4320H 16, 24, NSYSBMB208012 12,
45
NSYS3DC4315 16, 50, 50, 153 42, 45
60, 77 NSYS3DEX7525 352 NSYSBM15158 12, 42,
NSYS3X4320T 24, 153 NSYSBMC153012 12,
NSYS3DEX8630 352 45
NSYS3DC4320 16, 50, 42, 45
NSYS3X4420 16, 24, 50,
60, 77 NSYS3DLG 490, 491, NSYSBM152012 12, 42,
153 NSYSBMC154012 12,
499 45
NSYS3DC4420 16, 50, 42, 45
NSYS3X4420H 16, 24,
60, 77 NSYS3DTL 490 NSYSBM15208 12, 42,
50, 153 NSYSBMC203012 12,
45
NSYS3DC5420 16, 50, 42, 45
NSYS3HD10640 312, NSYS3X4620 24, 153
60, 77 317 NSYSBM153012 12, 42,
NSYSBMC204012 12,
NSYS3X4620H 24, 153 45
NSYS3DC5425 16, 50, 42, 45
NSYS3HD10840 312,
60, 77 317 NSYS3X5420 16, 24, 50, NSYSBM15308 12, 42,
NSYSBMC206012 12,
153 45
42, 45
NSYS3HD3215 312
514
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYSBMC208012 12, NSYSCX6050 166 NSYSDR120 260 NSYSF1810402D 20, 116 NSYSF2010502DP 20,
42, 45 116
NSYSCX8040 166 NSYSDR200 262 NSYSF1810402DP 20,
NSYSBMC303012 12, 116 NSYSF201050P 20, 116
NSYSCX8050 166 NSYSDR200B 262
42, 45
NSYSF181040P 20, 116 NSYSF201050T 20, 116
NSYSCX8060 166 NSYSDR200BD 262
NSYSBMC304012 12,
NSYSF181050 20, 116 NSYSF201060 20, 116
42, 45 NSYSD10 370, 379 NSYSDR200D 262
NSYSF181050P 20, 116 NSYSF2010602D 20, 116
NSYSBMC306012 12, NSYSD10R 370, 377, 379 NSYSDR30B 260
42, 45 NSYSF181060 20, 116 NSYSF2010602DP 20,
NSYSD12 370, 379 NSYSDR40B 260
116
NSYSBMC308012 12, NSYSF1810602D 20, 116
42, 45 NSYSD12R 370, 377, 379 NSYSDR50A 260
NSYSF201060P 20, 116
NSYSF1810602DP 20,
NSYSBMC404012 12, NSYSD6 370, 379 NSYSDR60 260
116 NSYSF201060T 20, 116
42, 45 NSYSD6R 370, 377, 379 NSYSDR60A 260
NSYSF181060P 20, 116 NSYSF201080 20, 116
NSYSBMC406012 12, NSYSD8 370, 379 NSYSDR80 260
42, 45 NSYSF1812402D 20, 116 NSYSF201080P 20, 116
NSYSD8R 370, 377, 379 NSYSDR80A 260
NSYSBMC408012 12, NSYSF1812402DP 20, NSYSF2012402D 20, 116
42, 45 NSYSDC42 376, 377 NSYSDRC 143, 326 116
NSYSF2012402DP 20,
NSYSBPLA 231, 233 NSYSDC43 376, 377 NSYSDRSDCR 236, 313 NSYSF1812502D 20, 116 116
NSYSBTB 247 NSYSDC62 376, 377 NSYSDRSDCR300 15, NSYSF1812502DP 20, NSYSF2012502D 20, 116
87, 240 116
NSYSC1030 138 NSYSDC63 376, 377 NSYSF2012502DP 20,
NSYSDRSDCR400 15, NSYSF1812602D 20, 116 116
NSYSC1040 138 NSYSDCR10 298
87, 240
NSYSF1812602DP 20, NSYSF2012602D 20, 116
NSYSC1050 138 NSYSDCR200 15, 24, 60, 116
NSYSDT● 326
82, 87, 155, 240, 352 NSYSF2012602DP 20,
NSYSC1060 138 NSYSDT5 142, 298 NSYSF18440 20, 116 116
NSYSDCR250 15, 24, 60,
NSYSC1230 138 87, 155, 240, 352 NSYSDT6 142, 298 NSYSF18450 20, 116 NSYSF2012802D 20, 116
NSYSC1240 138 NSYSDCR300 15, 24, 60, NSYSDT8 142, 298 NSYSF18460 20, 116 NSYSF2012802DP 20,
87, 155, 240, 352 116
NSYSC1250 138 NSYSDX10 25, 370, 377, NSYSF18640 20, 116
NSYSDCR4 298 379 NSYSF2016402D 20, 116
NSYSC1260 138 NSYSF18640P 20, 116
NSYSDCR400 15, 60, 87, NSYSDX12 25, 370, 377, NSYSF2016402DP 20,
NSYSC1640 138 NSYSF18640T 20, 116
240 379 116
NSYSC1650 138 NSYSF18650 20, 116
NSYSDCR5 298 NSYSDX6 25, 370, 377, NSYSF2016502D 20, 116
NSYSC1660 138 379 NSYSF18650P 20, 116
NSYSDCR6 298 NSYSF2016502DP 20,
NSYSC1850 138 NSYSDX8 25, 370, 377, NSYSF18650T 20, 116 116
NSYSDCR8 298
379
NSYSC1860 138 NSYSF18660 20, 116 NSYSF2016602D 20, 116
NSYSDCX42 376, 377
NSYSF12640 20, 116
NSYSC2050 138 NSYSF18660P 20, 116 NSYSF2016602DP 20,
NSYSDCX43 376, 377 116
NSYSF12640P 20, 116
NSYSC2060 138 NSYSF18660PC 385
NSYSDCX62 376, 377 NSYSF20350 20, 116
NSYSF12660 20, 116
NSYSC2450 138 NSYSF18680PC 385
NSYSDCX63 376, 377 NSYSF20360 20, 116
NSYSF12660P 20, 116
NSYSC2460 138 NSYSF18680T 20, 116
NSYSDF1010 370, 379 NSYSF20380 20, 116
NSYSF12840 20, 116
NSYSC630 138 NSYSF18840 20, 116
NSYSDF108 370, 379 NSYSF20440 20, 116
NSYSF12840P 20, 116
NSYSC640 138 NSYSF18840P 20, 116
NSYSDF1210 370, 379 NSYSF20450 20, 116
NSYSF12860 20, 116
NSYSC650 138 NSYSF18840T 20, 116
NSYSDF128 370, 379 NSYSF20460 20, 116
NSYSF12860P 20, 116
NSYSC660 138 NSYSF18850 20, 116
NSYSDF1610 370, 379 NSYSF20480 20, 116
NSYSF14640 20, 116
NSYSC830 138 NSYSF18850P 20, 116
NSYSDF168 370, 379 NSYSF20640 20, 116
NSYSF14640P 20, 116
NSYSC840 138 NSYSF18850T 20, 116
NSYSDF810 370, 379 NSYSF20640P 20, 116
NSYSF14840 20, 116
NSYSC850 138 NSYSF18860 20, 116
NSYSDF88 370, 379 NSYSF20640T 20, 116
NSYSF14840P 20, 116
NSYSC860 138 NSYSF188602D 20, 116
NSYSDFLOCKDB5 497 NSYSF20650 20, 116
NSYSF16660 20, 116
NSYSCCDINLG140 287 NSYSF188602DP 20, 116
NSYSDGCR10 286 NSYSF20650P 20, 116
NSYSF16660P 20, 116
NSYSCCDINLG75 287 NSYSF18860P 20, 116
NSYSDGCR5 286 NSYSF20650T 20, 116
NSYSF16660PC 385
NSYSCX10030 166 NSYSF18860T 20, 116
NSYSDGCR6 286 NSYSF20660 20, 116
NSYSF16680 20, 116
NSYSCX10040 166 NSYSF201040 20, 116
NSYSDGCR8 286 NSYSF20660P 20, 116
NSYSF16680P 20, 116
NSYSCX10060 166 NSYSF2010402D 20, 116
NSYSDH 380, 494, 497 NSYSF20680 20, 116
NSYSF16680PC 385
NSYSCX12040 166 NSYSF2010402DP 20,
NSYSDP●M 326 NSYSF20680P 20, 116
NSYSF16860 20, 116 116
NSYSCX12050 166
NSYSDP6M 142, 297 NSYSF20840 20, 116
NSYSF16860P 20, 116 NSYSF201040P 20, 116
NSYSCX12060 166
NSYSDP8M 142. 297 NSYSF20840P 20, 116
NSYSF16880 20, 116 NSYSF201040T 20, 116
NSYSCX16040 166
NSYSDR100 260 NSYSF20840T 20, 116
NSYSF16880P 20, 116 NSYSF201050 20, 116
NSYSCX16060 166
NSYSDR100A 260 NSYSF20850 20, 116
NSYSF181040 20, 116 NSYSF2010502D 20, 116
NSYSCX6040 166
515
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYSF20850P 20, 116 NSYSFC164 23, 119 NSYSFD1810T 22, 118 NSYSFHD1212602D NSYSFLOCKT7 145
312, 317
NSYSF20850T 20, 116 NSYSFC165 23, 119 NSYSFD18122D 22, 118 NSYSFLOCKT8 145
NSYSFHD12640 312,
NSYSF20860 20, 116 NSYSFC166 23, 119 NSYSFD18122DT 22, NSYSFLR●●● 275
317
118
NSYSF208602D 20, 116 NSYSFC35 23, 119 NSYSFHD12660 312, NSYSFLR105 139
NSYSFD184 22, 118,
NSYSF208602DP 20, 116 NSYSFC36 23, 119 317 NSYSFLR106 139
124, 141
NSYSF20860P 20, 116 NSYSFC44 22, 23, 118, NSYSFHD12840 312, NSYSFLR65 139
NSYSFD185 124, 141
119 317
NSYSF20860T 20, 116 NSYSFD186 22, 118, NSYSFLR66 139
NSYSFC45 22, 23, 118, NSYSFHD12860 312,
NSYSF20880 20, 116 124, 141 NSYSFLR85 139
119 317
NSYSF20880P 20, 116 NSYSFD186T 22, 118 NSYSFLR86 139
NSYSFC46 22, 23, 118, NSYSFHD1612402D
NSYSF20880T 20, 116 119 NSYSFD188 22, 118, 312, 317 NSYSFMDR 298
124, 141
NSYSF221060 20, 116 NSYSFC48 22, 23, 118, NSYSFHD1612602D NSYSFNDR 298
119 NSYSFD1882D 22, 118 312, 317
NSYSF221060P 20, 116 NSYSFP300 27, 200
NSYSFC64 22, 23, 118, NSYSFD188T 22, 118 NSYSFHD16660 312,
NSYSF2212602D 20, 116 119 317 NSYSFP400 27, 200
NSYSFD2010 23, 119
NSYSF2212602DP 20, NSYSFC65 22, 23, 118, NSYSFHD16840 312, NSYSFP500 27, 200
116 NSYSFD20102D 23, 119 317
119 NSYSFP5G20750 325
NSYSF2212802D 20, 116 NSYSFD2010T 23, 119 NSYSFHD16860 312,
NSYSFC66 22, 23, 118, NSYSFP5G20780 325
NSYSF2212802DP 20, 119 NSYSFD20122D 23, 119 317
116 NSYSFP600 27, 200
NSYSFC68 22, 23, 118, NSYSFD20122DT 23, NSYSFHD2 144
NSYSF22460 20, 116 119 119 NSYSFPB 247
NSYSFHD20840 312,
NSYSF22660 20, 116 NSYSFC84 22, 23, 118, NSYSFD20162D 23, 119 317 NSYSFPSC15 42
119 NSYSFHD3 144 NSYSFPSC20 42
NSYSF22660P 20, 116 NSYSFD203 23, 119
NSYSFC85 22, 23, 118, NSYSFHF18660 343 NSYSFPSC30 42, 68, 89,
NSYSF22680 20, 116 119 NSYSFD204 23, 119,
124, 141 95
NSYSF22680P 20, 116 NSYSFHF18840 343
NSYSFC86 22, 23, 118, NSYSFPSC30HD 312
119 NSYSFD205 124, 141 NSYSFHF18860 343
NSYSF22860 20, 116
NSYSFD206 23, 119, NSYSFPSC40 42, 68, 89,
NSYSF22860P 20, 116 NSYSFC88 22, 23, 118, NSYSFHF206100 343
124, 141 95
119
NSYSF22880 20, 116 NSYSFHF20640 343
NSYSFD206T 23, 119 NSYSFPSC40HD 312
NSYSFCVR124HD 312,
NSYSF22880P 20, 116 NSYSFHF20660 343
317 NSYSFD207 493 NSYSFPSC50 42, 68, 89,
NSYSFHF20680 343 95
NSYSF22880T 20, 116 NSYSFCVR126HD 312, NSYSFD207T 493
317 NSYSFHF208100 343 NSYSFPSC50HD 312
NSYSF5G20350 325 NSYSFD208 23, 119,
NSYSFCVR64HD 312, 124, 141 NSYSFHF20840 343 NSYSFPSC60 42, 68, 89,
NSYSF5G20380 325
317 95
NSYSF5G20680 323 NSYSFD2082D 23, 119 NSYSFHF20860 343
NSYSFCVR66HD 312, NSYSFPSC60HD 312
NSYSF5G20860 323 317 NSYSFD208T 23, 119 NSYSFHF20880 343
NSYSFPSC80 42, 68, 89,
NSYSFBK 126 NSYSFCVR84HD 312 NSYSFD2210 23, 119 NSYSFHF22660 343 95
NSYSFBK19 25, 126, NSYSFCVR86HD 312 NSYSFD2210T 23, 119 NSYSFHF22860 343 NSYSFPSC80HD 312
167 NSYSFD22122D 23, 119 NSYSFHF22880 343
NSYSFD126 22, 118, NSYSFSPLM 27, 200
NSYSFBKE 126 124, 141 NSYSFD22122DT 23, NSYSFHFBK184 347 NSYSFTB16 136
NSYSFBKF 126 NSYSFD126T 22, 118 119
NSYSFHFBK186 347 NSYSFTB18 136
NSYSFBKR 126 NSYSFD128 22, 118, NSYSFD224 23, 119,
NSYSFHFBK2010 347 NSYSFTB24 136
124, 141 124, 141
NSYSFBKSH 126 NSYSFHFBK204 347
NSYSFD225 124, 141 NSYSFTB32 136
NSYSFD128T 22, 118
NSYSFC104 22, 23, 118, NSYSFHFBK206 347
NSYSFD226 23, 119, NSYSFTBS 137
119 NSYSFD146 22, 118,
124, 141 124, 141 NSYSFHFBK208 347 NSYSFV12 22, 118
NSYSFC105 22, 23, 118,
119 NSYSFD146T 22, 118 NSYSFD226T 23, 119 NSYSFHFBK226 347 NSYSFV14 22, 118
NSYSFC106 22, 23, 118, NSYSFD148 22, 118, NSYSFD228 23, 119, NSYSFHFBK228 347 NSYSFV16 22, 118
119 124, 141 124, 141
NSYSFHNTRIM 493 NSYSFV18 22, 118
NSYSFC108 22, 23, 118, NSYSFD148T 22, 118 NSYSFD228T 23, 119
NSYSFHS1 144 NSYSFV20 23, 119
119 NSYSFEB 136
NSYSFD166 22, 118, NSYSFLOCK24 145
NSYSFC124 22, 23, 118, 124, 141 NSYSFV22 23, 119
NSYSFECA64HD 499
119 NSYSFLOCKDB5 145 NSYSFVG 493
NSYSFD166T 22, 118 NSYSFECA66HD 317,
NSYSFC125 22, 23, 118, NSYSFLOCKS6 145 NSYSFWFIX 140
NSYSFD168 22, 118, 499
119 NSYSFLOCKS7 145
124, 141 NSYSFELB 136 NSYSFX181240 25, 161
NSYSFC126 22, 23, 118, NSYSFLOCKS8 145
NSYSFD168T 22, 118 NSYSFHD1212402D NSYSFX18640 25, 161
119
NSYSFD1810 22, 118 312, 317 NSYSFLOCKSG8 145
NSYSFC128 22, 23, 118, NSYSFX18840 25, 161
119 NSYSFD18102D 22, 118 NSYSFLOCKT6 145 NSYSFX201060 25, 161
516
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYSFX201260 25, 161 NSYSM1610302DP 18, NSYSM18830 18, 114 NSYSM20850P 18, 114 NSYSMP2D5 248
114
NSYSFX20650 25, 161 NSYSM18830P 18, 114 NSYSM20850T 18, 114 NSYSMP2D6 248
NSYSM1610402D 18,
NSYSFX20840 25, 161 NSYSM18830T 18, 114 NSYSM20860 18, 114 NSYSMP2D8 248
114
NSYSFX20860 25, 161 NSYSM18840 18, 114 NSYSM20860P 18, 114 NSYSMPB 247, 248
NSYSM1610402DP 18,
NSYSFXJG 25, 167 114 NSYSM18840P 18, 114 NSYSM20860T 18, 114 NSYSMPE● 326
NSYSGF 133 NSYSM1612302D 18, NSYSM18840T 18, 114 NSYSMBCE10 135 NSYSMPFA 243
114
NSYSH180 143 NSYSM18850 18, 114 NSYSMBCE6 135 NSYSMPFB 243, 326
NSYSM1612302DP 18,
NSYSIBTB 247 114 NSYSM18850P 18, 114 NSYSMBCE8 135 NSYSMPS4 247
NSYSIMP12 21, 116, 243 NSYSM1612402D 18, NSYSM18850T 18, 114 NSYSMBK 126 NSYSMPS5 247
NSYSIMP14 21, 116, 243 114 NSYSM18860 18, 114 NSYSMD12102D 493 NSYSMPS6 247
NSYSIMP16 21, 116, 243 NSYSM1612402DP 18, NSYSM18860P 18, 114 NSYSMD12122D 493 NSYSMPS8 247
114
NSYSIMP18 21, 116, 243 NSYSM2010402D 18, NSYSMD14102D 493 NSYSMPSB 247, 326
NSYSM16630 18, 114 114
NSYSIMP20 21, 116, 243 NSYSMD14122D 493 NSYSMPSE10 248
NSYSM16630P 18, 114 NSYSM2010402DP 18,
NSYSIMP22 21, 116, 243 NSYSMD16102D 493 NSYSMPSE12 248
NSYSM16640 18, 114 114
NSYSKAV 313 NSYSMD16122D 493 NSYSMPSE6 248
NSYSM16640P 18, 114 NSYSM2010502D 18,
NSYSLCKP 395 114 NSYSMD18162D 493 NSYSMPSE8 248
NSYSM16640T 18, 114
NSYSLCKS10 395 NSYSM2010502DP 18, NSYSMDR 298 NSYSMVR12 258
NSYSM16830 18, 114 114
NSYSLCKS6 395 NSYSMEB 136, 167 NSYSMVR14 258
NSYSM16830P 18, 114 NSYSM2012402D 18,
NSYSLCKS8 395 114 NSYSMEC103 134 NSYSMVR16 258
NSYSM16830T 18, 114
NSYSLCR40 256 NSYSM2012402DP 18, NSYSMEC1031 493 NSYSMVR18 258
NSYSM16840 18, 114
NSYSLCR50 256 114 NSYSMEC104 134 NSYSMVR20 258
NSYSM16840P 18, 114
NSYSLCR60 256 NSYSM2012502D 18, NSYSMEC1041 493 NSYSMWFIX 140
NSYSM16840T 18, 114 114
NSYSLCR80 256 NSYSMEC105 134 NSYSMX141030 25, 161
NSYSM181040 18, 114 NSYSM2012502DP 18,
NSYSM10M5HP 291 114 NSYSMEC1051 493 NSYSMX16660PC 389
NSYSM1810402D 18,
NSYSM1210302D 18, 114 NSYSM2012602D 18, NSYSMEC63 134 NSYSMX16840 25, 161
114 114
NSYSM1810402DP 18, NSYSMEC631 493 NSYSMX181240 25, 161
NSYSM1210302DP 18, 114 NSYSM2012602DP 18, NSYSMEC64 134 NSYSMX181240H 161
114 114
NSYSM181040P 18, 114 NSYSMEC641 493 NSYSMX181640 25, 161
NSYSM1212402D 18, NSYSM2016402D 18,
114 NSYSM1810502D 18, 114 NSYSMEC65 134 NSYSMX181640H 161
114
NSYSM1212402DP 18, NSYSM2016402DP 18, NSYSMEC651 493 NSYSMX18640 25, 161
114 NSYSM1810502DP 18, 114
114 NSYSMEC66 134 NSYSMX18660PC 389
NSYSM12830 18, 114 NSYSM2016502D 18,
NSYSM1812402D 18, NSYSMEC661 493 NSYSMX18840 25, 161
NSYSM12830P 18, 114 114
114
NSYSMEC83 134 NSYSMX18840H 161
NSYSM1410402D 18, NSYSM2016502DP 18,
NSYSM1812402DP 18, 114
114 NSYSMEC831 493 NSYSMX201040 25, 161
114
NSYSM1410402DP 18, NSYSM2016602D 18, NSYSMEC84 134 NSYSMX201040H 161
NSYSM1812502D 18, 114
114 114 NSYSMEC841 493 NSYSMX201250 25, 161
NSYSM1412402D 18, NSYSM2016602DP 18,
NSYSM1812502DP 18, 114 NSYSMEC85 134 NSYSMX201250H 161
114 114
NSYSM20630 18, 114 NSYSMEC851 493 NSYSMX201660 25, 161
NSYSM1412402DP 18, NSYSM1816402D 18,
114 NSYSM20630P 18, 114 NSYSMEC86 134 NSYSMX201660H 161
114
NSYSM14630 18, 114 NSYSM20640 18, 114 NSYSMEC861 493 NSYSMX20850 25, 161
NSYSM1816402DP 18,
NSYSM14630P 18, 114 114 NSYSMHF18660P 343 NSYSNLPLA 224
NSYSM20640P 18, 114
NSYSM14640 18, 114 NSYSM1816502D 18, NSYSMHF18860P 343 NSYSNM6 250, 263, 268
NSYSM20640T 18, 114
114
NSYSM14640P 18, 114 NSYSM20650 18, 114 NSYSMHF20840P 343 NSYSNM8 250, 263, 268
NSYSM1816502DP 18,
NSYSM14830 18, 114 114 NSYSM20650P 18, 114 NSYSMHF20860P 343 NSYSNSM6 250, 263,
268
NSYSM14830P 18, 114 NSYSM18630 18, 114 NSYSM20830 18, 114 NSYSMHR10 258
NSYSNSM8 250, 263,
NSYSM14840 18, 114 NSYSM18630P 18, 114 NSYSM20830P 18, 114 NSYSMHR12 258 268
NSYSM14840P 18, 114 NSYSM18640 18, 114 NSYSM20830T 18, 114 NSYSMHR16 258 NSYSODS 395
NSYSM14840T 18, 114 NSYSM18640P 18, 114 NSYSM20840 18, 114 NSYSMHR6 258 NSYSPB6100 133
NSYSM1610302D 18, NSYSM18640T 18, 114 NSYSM20840P 18, 114 NSYSMHR8 258 NSYSPB8100 133
114 NSYSMNDR 298
NSYSM18650 18, 114 NSYSM20840T 18, 114 NSYSPC 291
NSYSM18650P 18, 114 NSYSM20850 18, 114 NSYSMP2D4 248 NSYSPC4100 133
517
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYSPC5100 133 NSYSPFX12100H 26, NSYSPRJ 296 NSYSPSX5200SF 25, NSYSTDNCSX 157
164, 165, 378 165
NSYSPC6100 133 NSYSPS3100 18, 114, NSYSTMP22100 242
NSYSPFX12200 25, 164, 133 NSYSPSX6100 25, 164
NSYSPC8100 133 NSYSTMP22120 242
165, 312
NSYSPS3100SD 89, 97 NSYSPSX6100H 164,
NSYSPCP 16, 50, 291 NSYSTMP2260 242
NSYSPFX12200H 25, 165, 389
NSYSPS3200 18, 114,
NSYSPCR 133 164, 165, 378 NSYSTMP2280 242
133 NSYSPSX6100SF 25,
NSYSPF10100 18, 21, NSYSPFX16100 25, 164 165 NSYSTMP45100 242
NSYSPS3200SD 89, 97
89, 97, 114, 116, 133, 378
NSYSPFX16100H 164 NSYSPSX6200 25, 164 NSYSTMP45120 242
NSYSPS4100 18, 21,
NSYSPF10200 18, 21,
NSYSPFX16200 25, 164 114, 116, 133 NSYSPSX6200H 164, NSYSTMP4560 242
89, 97, 114, 116, 133, 378
165
NSYSPFX16200H 164 NSYSPS4100SD 89, 97, NSYSTMP4580 242
NSYSPF12100 18, 21,
378 NSYSPSX6200SF 25,
89, 97, 378 NSYSPFX6100 25, 164, NSYSTMP60100 242,
165, 312
165 NSYSPS4200 18, 21, 382
NSYSPF12200 18, 21,
114, 116, 133 NSYSPV6100 133
89, 97, 114, 116, 133, 378 NSYSPFX6100H 25, 378, NSYSTMP60120 242,
389 NSYSPS4200SD 89, 97, NSYSPV8100 133 382
NSYSPF16100 18, 21,
378
114, 116, 133, 378 NSYSPFX6200 25, 164, NSYSQCR12040 493 NSYSTMP6060 242
165 NSYSPS5100 18, 21,
NSYSPF16200 18, 21, NSYSQCR12050 493 NSYSTMP6080 242, 382
114, 116, 133
114, 116, 133, 378 NSYSPFX6200 25, 312
NSYSQCR12060 493 NSYSTMP82100 242
NSYSPS5100SD 378
NSYSPF3100 21, 116, NSYSPFX6200H 378,
NSYSQCR12080 493 NSYSTMP82120 242
133 389 NSYSPS5200 18, 21,
114, 116, 133 NSYSQCR40100 254 NSYSTMP8260 242
NSYSPF3200 21, 116, NSYSPFX8100 25, 97,
133 155, 164, 165 NSYSPS5200SD 378 NSYSQCR40120 254 NSYSTMP8280 242
NSYSPF4100 21, 116, NSYSPFX8100H 25, 97, NSYSPS6100 18, 21, NSYSQCR4040 254, 259 NSYSTW 296
133 155, 164, 165, 378 114, 116, 133, 386
NSYSQCR4050 254, 259 NSYSUCR40100 254
NSYSPF4200 21, 116, NSYSPFX8200 25, 97, NSYSPS6100SD 378
133 155, 164, 165, 378 NSYSQCR4060 254, 259 NSYSUCR40110 133,
NSYSPS6200 18, 21, 254
NSYSPF6100 18, 21, 89, NSYSPFX8200H 25, 97, 114, 116, 133, 386 NSYSQCR4060 386
97, 114, 116, 133, 378, 155, 164, 378 NSYSQCR4080 254, 259, NSYSUCR40120 254
NSYSPS6200SD 378
386 386 NSYSUCR40140 254
NSYSPLA100 231, 233
NSYSPS8100 21, 116,
NSYSPF6200 18, 21, 89, NSYSQCR65100 254 NSYSUCR40150 133
NSYSPLA125 231, 233 133, 386
97, 114, 116, 133, 378,
386 NSYSPLA150 231, 233 NSYSPS8200 21, 116, NSYSQCR65120 254 NSYSUCR40160 254
133, 386 NSYSQCR6540 254 NSYSUCR40180 254
NSYSPF8100 18, 21, 89, NSYSPLA75 231, 233
97, 114, 116, 133, 378 NSYSPSJ 296 NSYSQCR6550 254
NSYSPLK 131 NSYSUCR40200 254
NSYSPF8200 18, 21, 89, NSYSPSX3100 25, 97, NSYSQCR6560 254
NSYSPLVX3200 312 NSYSUCR40220 254
97, 114, 116, 133, 378 155, 164
NSYSPLVX4200 312, NSYSQCR6580 254 NSYSUCR4030 133, 245
NSYSPFC16100 133 NSYSPSX3100H 97, 155,
317 164 NSYSQCR90100 254 NSYSUCR4040 133, 254,
NSYSPFC16200 133
NSYSPLVX4200SF 312 NSYSQCR90120 254 259
NSYSPSX3200 25, 97,
NSYSPFC18100 133
NSYSPLVX6200 317 155, 164, 312, 317 NSYSQCR9040 254 NSYSUCR4050 133, 254,
NSYSPFC18200 133 259
NSYSPLVX6200SF 312 NSYSPSX3200H 97, 155, NSYSQCR9050 254
NSYSPFC24100 133 164 NSYSUCR4060 254, 259,
NSYSPM6 131 NSYSQCR9060 254 386, 441
NSYSPFC24200 133 NSYSPSX4100 25, 164
NSYSPMP25100 226, NSYSQCR9080 254 NSYSUCR4070 133, 254
NSYSPFV6100 133 242 NSYSPSX4100H 164,
165 NSYSRCE1050 139 NSYSUCR4080 254, 259,
NSYSPFV8100 133 NSYSPMP25120 242 386, 441
NSYSPSX4100SF 25, NSYSRCE1060 139
NSYSPFVX12200 312, NSYSPMP2560 242 NSYSUCR4090 133, 254
165
317 NSYSRCE650 139
NSYSPMP2575 226, 242 NSYSPSX4200 25, 164, NSYSUCR65100 254
NSYSPFVX6200 312, NSYSRCE660 139
NSYSPMP2580 242 312
317 NSYSUCR65120 254
NSYSRCE850 139
NSYSPMP40100 226, NSYSPSX4200H 164,
NSYSPFVX8200 312, NSYSUCR65140 254
242, 382 165 NSYSRCE860 139
317
NSYSUCR65160 254
NSYSPMP40120 242, NSYSPSX4200SF 25, NSYST30M6 268
NSYSPFX10100 25, 97,
382 165, 312 NSYSUCR65180 254
155, 164, 165 NSYST30M6S 256, 268
NSYSPMP40160 242, NSYSPSX5100 25, 164 NSYSUCR65200 254
NSYSPFX10100H 25, 97, NSYST40M8 268
155, 164, 165, 378 382 NSYSPSX5100H 25, 164, NSYSUCR65220 254
165, 378 NSYSTBR3 248
NSYSPFX10200 25, 97 NSYSPMP4060 242 NSYSUCR6530 254
NSYSPSX5100SF 25, NSYSTBR4 248
NSYSPFX10200H 25, 97, NSYSPMP4080 242, 382 NSYSUCR6540 254
165 NSYSTBR5 248
155, 164, 165, 378 NSYSPMP60100 242
NSYSPSX5200 25, 164 NSYSUCR6550 254
NSYSPFX12100 25, 164, NSYSTBR6 248
NSYSPMP60120 242 NSYSUCR6560 254
165 NSYSPSX5200H 164, NSYSTDCSX 157
NSYSPMP6060 242 165 NSYSUCR6580 254
NSYSTDCXH 157
NSYSPMP6080 242
518
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYSUCR90100 254 NSYTBP241910H 13, NSYTBS241910T 13, 172 NSYTCSPLM 50, 16, NSYTJ10030 60, 71, 89,
172 195, 204 99
NSYSUCR90110 133, NSYTBS241912H 13,
254 NSYTBP241910HT 13, 172 NSYTCT274 190 NSYTJ10040 71, 89, 99
172
NSYSUCR90120 254 NSYTBS241912HT 13, NSYTCT276 190 NSYTJ12030 71, 89, 99
NSYTBP241910T 13, 172 172
NSYSUCR90140 254 NSYTCT278 190 NSYTJ12040 71, 89, 99
NSYTBP241912H 13, NSYTBS24198 13, 172
NSYSUCR90150 133 NSYTDB5ME 166, 202 NSYTJ2015 60, 71, 89,
172
NSYTBS24198T 13, 172 99
NSYSUCR90160 254 NSYTDB5PL 202
NSYTBP241912HT 13,
NSYTBS292412 13, 172 NSYTJ2515 71, 89, 99
NSYSUCR90180 254 172 NSYTDBCRN 100, 202
NSYTBS292412H 13, NSYTJ2520 71, 89, 99
NSYSUCR90200 254 NSYTBP24198 13, 172 NSYTEC6PL 203
172
NSYTJ3015 60, 71, 89,
NSYSUCR90220 254 NSYTBP24198T 13, 172 NSYTEC7ML 101
NSYTBS292412HT 13, 99
NSYSUCR9030 133, 254 NSYTBP292412 13, 172 172 NSYTEC7PL 203
NSYTJ3020 60, 71, 89,
NSYSUCR9040 133, 254 NSYTBP292412H 13, NSYTBS292412T 13, 172 NSYTEC8ML 101 99
172
NSYSUCR9050 133, 254 NSYTBS292416H 13, NSYTEC8PL 203 NSYTJ4015 71, 89, 99
NSYTBP292412HT 13, 172
NSYSUCR9060 254, 323 NSYTEDB5ML 101 NSYTJ4020 60, 71, 89,
172
NSYTBS292416HT 13, 99
NSYSUCR9070 133, 254 NSYTBP292412T 13, 172 172 NSYTEDB5PL 203
NSYTJ4025 60, 71, 89,
NSYSUCR9080 254, 323 NSYTBP292416H 13, NSYTBS29248 13, 172 NSYTEL1242EPL 203 99
NSYSUCR9090 133, 254 172 NSYTEL405ML 101
NSYTBS29248T 13, 172 NSYTJ5015 71, 89, 99
NSYSUPLA3 218 NSYTBP292416HT 13, NSYTEL405PL 203
NSYTBS342912 13, 172 NSYTJ5020 60, 71, 89,
172
NSYSUPLA3T 218 NSYTELFACPL 203 99
NSYTBS342912T 13, 172
NSYTBP29248 13, 172
NSYSUPLA4 218 NSYTELJISPL 203 NSYTJ5025 60, 71, 89,
NSYTBS342916H 13,
NSYTBP29248T 13, 172 99
NSYSUPLA4T 218 172 NSYTEMPL 203
NSYTBP342912 13, 172 NSYTJ6020 60, 71, 89,
NSYSVR606 138 NSYTBS342916HT 13, NSYTERML 101 99
NSYTBP342912T 13, 172 172
NSYSVR608 138 NSYTERPL 203 NSYTJ6025 60, 71, 89,
NSYTBP342916H 13, NSYTBS775 13, 172
NSYSVR806 138 NSYTET6PL 203 99
172
NSYTBS885 13, 172
NSYSVR808 138 NSYTET7ML 101 NSYTJ6030 60, 71, 89,
NSYTBP342916HT 13,
NSYTC12100 289 99
NSYSW 296 172 NSYTET7PL 203
NSYTC6CRN 35, 100, NSYTJ6040 60, 71, 89,
NSYSWMBP 490, 491, NSYTBP775 13, 172 NSYTET8ML 101
202 99
492, 499 NSYTBP885 13, 172
NSYTC6CSX 157 NSYTET8PL 203 NSYTJ8020 71, 89, 99
NSYSWMCH 490, 491, NSYTBPASBS 183
NSYTC6ME 166, 202 NSYTEX5 188, 205 NSYTJ8025 60, 71, 89,
492, 499
NSYTBS111113H 13, 172 99
NSYTC6ML 101 NSYTEX6 205
NSYSWMEL 490, 491,
492, 498, 499 NSYTBS11116 13, 172 NSYTJ8030 60, 71, 89,
NSYTC6PL 203 NSYTEX8 213, 226, 231,
99
NSYTBS1176 13, 172 309, 310
NSYT… NSYTC7CRN 35, 100, NSYTJ8040 60, 71, 89,
NSYTBS1179H 13, 172 202, 380 NSYTEX8PLM 205
NSYTBP11116 13, 172 99
NSYTBS1397 13, 172 NSYTC7CSX 157 NSYTFL13CRNA 87, 102
NSYTBP1176 13, 172 NSYTJPLA103 31, 219
NSYTBS1397T 13, 172 NSYTC7ME 166, 202 NSYTFL13CRNB 87, 102
NSYTBP1397 13, 172 NSYTJPLA104 31, 219
NSYTBS16128 13, 172 NSYTC7ML 101 NSYTFL21CRNC 87, 102
NSYTBP1397T 13, 172, NSYTJPLA123 31, 219
172 NSYTBS16128T 13, 172 NSYTC7PL 203 NSYTFL21CRND 87, 102
NSYTJPLA124 31, 219
NSYTBP16128 13, 172 NSYTBS191210H 13, NSYTC8CRN 35, 100, NSYTFPCRN10 60, 287
NSYTJPLA53 31, 219
NSYTBP16128T 13, 172 172 166, 202, 380 NSYTFPCRN4 60, 287
NSYTJPLA54 31, 219
NSYTBP191210H 13, NSYTBS191210HT 13, NSYTC8ML 101 NSYTFPCRN5 60, 287
172 NSYTJPLA73 31, 219
172 NSYTC8PL 203 NSYTFPCRN6 60, 287
NSYTBS19128 13, 172 NSYTJPLA74 31, 219
NSYTBP191210HT 13, NSYTCD274 190 NSYTFPCRN8 60, 287
172 NSYTBS19128T 13, 172 NSYTL●2FL 275
NSYTCD276 190 NSYTHL1242EPLM 202
NSYTBP19128 13, 172 NSYTBS191610H 13, NSYTL●FL 275
NSYTCD278 190 NSYTHL2331APLM 202
NSYTBP19128T 13, 172 172
NSYTL1242EME 202
NSYTCL405ME 166, 202 NSYTHL2433APLM 202
NSYTBP191610H 13, NSYTBS191610HT 13,
NSYTL220PLM 202
172 172 NSYTCM274 190 NSYTHL3113APLM 202
NSYTL27270 185, 189,
NSYTBP191610HT 13, NSYTBS19168 13, 172 NSYTCM276 190 NSYTHL3131APLM 202 191
172 NSYTBS19168T 13, 172 NSYTCM278 190 NSYTHL405PLM 202 NSYTL27360 189
NSYTBP19168 13, 172 NSYTBS241910 13, 172 NSYTCRE1 492 NSYTHL421PLM 202 NSYTL405PLM 202
NSYTBP19168T 13, 172 NSYTBS241910H 13, NSYTCRE12 492 NSYTHL455PLM 202 NSYTL405SML 101
NSYTBP241910 13, 172 172
NSYTCSM6PLM 204 NSYTHL610PLM 202 NSYTLA4420 27, 201
NSYTBS241910HT 13,
172 NSYTHPLM 202 NSYTLA6420 27, 201
519
Universal Enclosures Index of references
Reference and Page Reference and Page Reference and Page Reference and Page Reference and Page
NSYTLAUHD 499 NSYTPLS5454 186 NSYTSA2429SE 278 NSYTX2515 24, 156 NSYVDM17UF 267, 60,
88
NSYTLBFL 283 NSYTPLS5454A 186 NSYTSACRNA 76, 77, NSYTX3015 24, 156
87, 102 NSYVDM20U8P 267, 60,
NSYTLC 139 NSYTPLS5472A 186 NSYTX3020 24, 156
88
NSYTSACRNB 76, 77,
NSYTLCFL 139, 283 NSYTPLSC1827 186 NSYTX4020 24, 156
87, 102 NSYVDM20UP 267, 60,
NSYTLCME 139, 278 NSYTPLSC2727 186 NSYTX5025 24, 156 88
NSYTSACRNC 76, 77,
NSYTLCRNA 87, 102 NSYTPLSC2727A 186 86, 87, 102 NSYTX6020 24, 156 NSYVDM21UF 267, 60,
88
NSYTLCRNB 87, 102 NSYTPLSC2736 186 NSYTSACRND 76, 77, NSYTX6025 24, 156
87, 102 NSYVDM25U8P 267, 60,
NSYTLCRNC 87, 102 NSYTPLSC2736A 186 NSYTX8030 156 88
NSYTSAKFL 280
NSYTLCRND 87, 102 NSYTPLSC2754 186 NSYU… NSYVDM7UP 267, 60, 88
NSYTSAM504SE 278
NSYTLCRNO 87, 102 NSYTPLSC2754A 186 NSYUCA22 265 NSYVDM8UF 267, 88
NSYTSAM508SE 278
NSYTLCU 139 NSYTPLSC3636 186 NSYUCA44 265 NSYVEA9 205
NSYTSAM6313SE 278
NSYTLCUHD 499 NSYTPLSC3654 186 NSYUCC••• 191 NSYVPLA10 496
NSYTSAM638SE 278
NSYTLD 87, 103 NSYTPLSC3654A 186 NSYUCC270 189 NSYVPLA10M 496
NSYTSML 101, 157
NSYTLDFL 87, 103, 283 NSYTPLSC3672A 186 NSYUCC360 189 NSYVPLA12 496
NSYTSMLS3D 72
NSYTLDME 87, 278 NSYTPLSC5454 186 NSYUM••• 191 NSYVPLA12M 496
NSYTSPLA 225
NSYTLDUHD 499 NSYTPLSC5454A 186 NSYUM27180 189 NSYVPLA15 496
NSYTT6CRN 35, 100,
NSYTLE 87, 103 NSYTPLSC5472A 186 202 NSYUM27270 189, 191 NSYVPLA15M 496
NSYTLEFL 87, 103, 283 NSYTPLSP1827 186 NSYTT6ME 166, 202 NSYUM27360 189 NSYVPLA5 496
NSYTLEME 87, 278 NSYTPLSP2727 186 NSYTT6PL 203 NSYUR20 265 NSYVPLA5M 496
NSYTLEUHD 499 NSYTPLSP2736 186 NSYTT7CRN 35, 100 NSYUR40 265 NSYVPLA7 496
NSYTLF2FL 283 NSYTPLSP2754 186 NSYTT7ML 101 NSYUR60 265 NSYVPLA7M 496
NSYTLFFL 283 NSYTPLSP3636 186 NSYTT7PL 203 NSYUT20 265 NSYVPLM108 497
NSYTLFME 278 NSYTPLSP3654 186 NSYTT8CRN 35, 100, NSYUT40 265 NSYVR18 19, 21, 115,
NSYTLG 87, 103 NSYTPLSP5454 186 202, 380 NSYUT60 265 116, 167, 250
NSYTLG2FL 87, 103, 283 NSYTRIM10S18 494 NSYTT8CSX 157 NSYUTA22 265 NSYVR20 19, 21, 115,
116, 167, 250
NSYTLG4FL 275, 283 NSYTRIM10S6 494 NSYTT8ME 166, 202 NSYUTA42 265
NSYVR22 21, 116, 250
NSYTLGFL 283 NSYTRIM10SF 22, 23, NSYTT8ML 101 NSYUTA44 265
118, 119, 143 NSYTT8PL 203
NSYW…
NSYTLGME 87, 278 NSYUVPLA 218
NSYTRIM10SF2D 22, 23, NSYWMK33 69, 89, 96
NSYTLGUHD 499 NSYTTG40 259
118, 119, 143 NSYV…
NSYWMK34 69, 89, 96
NSYTLJISME 202 NSYTTG50 259
NSYTRIM12SF2D 22, 23, NSYVA2710M 300
NSYWMK43 69, 89, 96
NSYTLREP 103 118, 119, 143 NSYTTG60 259, 386, 389
NSYVA2710MA 300
NSYWMK44 69, 89, 96
NSYTLRME 202 NSYTRIM16SF2D 23, NSYTUP7032 303
NSYVA2712M 300
119, 143 NSYZ…
NSYTMME 202 NSYTUP7035 303
NSYVA2712MA 300
NSYTRIM3SF 23, 119, NSYZA2103 31, 220
NSYTMP42100 382 NSYTVR10 226, 250
143 NSYVA2716M 300
NSYTVR12 19, 21, 115, NSYZA2104 31, 220
NSYTMP42120 382 NSYTRIM4SF 22, 23, NSYVA2724M 300
116, 250 NSYZA2123 31, 220
NSYTMP4280 382 118, 119, 143
NSYVA272M 300
NSYTVR125 226, 250 NSYZA2124 31, 220
NSYTMP67100 382 NSYTRIM5SF 143
NSYVA272MA 300
NSYTVR14 19, 21, 115, NSYZA253 31, 220
NSYTMP67120 382 NSYTRIM6S18 494
116, 167, 250, 383 NSYVA2736M 16, 50
NSYTRIM6S6 494 NSYZA254 31, 220
NSYTMP6760 382 NSYTVR15 226, 250 NSYVA274M 16, 50, 300
NSYTRIM6SF 22, 23, NSYZA273 31, 220
NSYTMP6780 382 NSYTVR16 19, 21, 115, NSYVA274MA 300
118, 119, 143 NSYZA274 31, 220
NSYTPLS1827 186 116, 167, 250
NSYVA276M 300
NSYTRIM7SFP 143 NSYZHPLA103 31, 222
NSYTPLS2727 186 NSYTVR18 19, 21, 115,
116, 167, 250 NSYVA276MA 300
NSYTRIM8S18 494 NSYZHPLA104 31, 222
NSYTPLS2727A 186
NSYTRIM8S6 494 NSYTVR20 19, 21, 115, NSYVA278M 300 NSYZHPLA123 31, 222
NSYTPLS2736 186 116, 167, 250
NSYTRIM8SF 22, 23, NSYVA278MA 300 NSYZHPLA124 31, 222
NSYTPLS2736A 186 118, 119, 143 NSYTVR22 21, 116, 250
NSYVDM●●●● 330, 333 NSYZHPLA53 31, 222
NSYTPLS2754 186 NSYTRIM8SF2D 22, 23, NSYTVR7 226, 250
NSYVDM11UP 267, 60, NSYZHPLA54 31, 222
NSYTPLS2754A 186 118, 119, 143
NSYTVR8 250, 383 88
NSYTSA2414SE 278 NSYZHPLA73 31, 222
NSYTPLS3636 186 NSYTX10030 24, 156 NSYVDM12UF 267, 60,
NSYTSA2417SE 278 88 NSYZHPLA74 31, 222
NSYTPLS3654 186 NSYTX12030 24, 156
NSYTSA2422SE 278 NSYVDM16UP 267, 60, NSYZM253 27, 199
NSYTPLS3654A 186 NSYTX12030 24, 156
88
NSYTSA2423SE 278 NSYZM263 27, 199
NSYTPLS3672A 186 NSYTX2015 24, 156
520
Universal Enclosures Index of references
OLPU…
OLPU186 494
OLPU188 494
OLPU188KT 494
OLPU2010 494
OLPU206 494
OLPU208 494
OLPU208KT 494
XALE…
XALE2 173
XALE2141 173
XALE3 173
XALE3255 173
XALEK1702 173
521
Schneider Electric USA, Inc.
The information provided in this documentation contains general descriptions and/or technical
800 Federal Street
characteristics of the performance of the products contained herein. This documentation is not
Andover, MA 01810 USA
intended as a substitute for and is not to be used for determining suitability or reliability of these
888-778-2733
products for specific user applications. It is the duty of any such user or integrator to perform the
www.schneider-electric.us
appropriate and complete risk analysis, evaluation and testing of the products with respect to the
relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or
subsidiaries shall be responsible or liable for misuse of the information contained herein.
Schneider Electric is the trademark and the property of Schneider Electric SE, its subsidiaries,
and affiliated companies. All other trademarks are the property of their respective owners.
9993CT0901R08/16
Replaces 9993CT0901R02/13 dated 02/2013
August 2016