Shear Wall Notes:: Fin. Flr. 0'-0" A.F.F

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SHEAR WALL NOTES:

1. 1/2" CDX SHEATHING ON EXTERIOR SIDE OF WALL.

2. 6D NAILS @ 4" O.C. AT ALL PANEL EDGES.

3. 6D NAILS @ 6" O.C. AT ALL PANEL INTERMEDIATE MEMBERS.


4. 1/2" GYPSUM BOARD AT INTERIOR SIDE OF WALL.

1/2" DIA. A.B. W/ 6" MIN.


33' EMBEDMENT & 1-1/2" DIA.

12' 7'-6"
CONC. STEPS
12'
WASHERS @ 32" O.C. MAX. @
WALL LOCATIONS TERMITE PROTECTION
1'-6" VARY PER GRADE
9'-7" 2 X 6 P.T. BOT. PLATE
3 1/2" CONC. SLAB WITH FIBER MESH OVER
NOTES:

8"
SIMPSON SP1 @ EA. STUD 6 MIL. VAPOR BARRIER
1. APPROVED TERMITE PROTECTIVE TREATMENT SHALL BE USED AND PROVIDED. (PER FBC
RESIDENTIAL SIXTH EDITION (2017), SECTION R318.1)

8"
FINISH FLOOR 2. PERMANENT SIGNAGE FOR TREATMENT SHALL BE POSTED NEAR WATER HEATER OR

7" MIN.
2 30"Х30"Х12D CONC. 30"Х30"Х12D CONC. 30"Х30"Х12D CONC. 1 30"Х30"Х12D CONC. 0'-0" A.F.F. ELECTRICAL PANEL. (PER FBC RESIDENTIAL SIXTH EDITION (2017), SECTION R318.1)
5'-4"
6'

6'
FOOTING FOOTING FOOTING FOOTING
s1.1 W/(3) #5 BARS E.W. W/(3) #5 BARS E.W. W/(3) #5 BARS E.W. a3.1 W/(3) #5 BARS E.W. 3. A 6" MINIMUM CLEARANCE SHALL BE PROVIDED BETWEEN EXTERIOR WALLS AND GRADE
FIN. FLR. FOR TERMITE INSPECTION (4" MINIMUM FOR GARAGE/PATIO SLABS). (PER FBC RESIDENTIAL
SIXTH EDITION (2017), SECTION R318.1)

24"
0'-0" A.F.F. WELL COMPACTED TERMITE
8" MIN. TREATED FILL 4. A 1'-0" MINIMUM CLEARANCE SHALL BE PROVIDED BETWEEN THE STRUCTURE'S SIDEWALLS
WINDOW WINDOW DOOR DOOR WINDOW WINDOW AND CONDENSATE LINES, ROOF DOWNSPOUTS, SPRINKLER SYSTEMS AND RISERS FOR SPRAY

3" MIN
4 HEADS. (PER FBC RESIDENTIAL SIXTH EDITION (2017), R318.1.6)
5. APPROVED TERMITE PROTECTION SHOULD BE PLACED/PROTECTED W/ 6MIL VAPOR
G1.2 (2) #5 REBAR BARRIER. IT SHALL BE DONE AFTER EXCAVATION, BACKFILLING AND COMPACTION. ANY SOIL
18" DISTURBANCE AFTER TREATMENT SHALL BE PROTECTED BY PERMANENT PLASTIC OR METAL
2,500 PSI MINIMUM

WINDOW
FORMS IN CONCRETE FLOORS BOXED OUT OR CONSTRUCTED FOR THE INSTALLATION OF
WINDOW

PLUMBING LINES AND THE LIKE. IF SOIL IF DISTURBED AFTER TREATMENT, SOIL SHOULD BE
3 1/2" CONC. SLAB OVER @ WELL
1 COMPACTED TERMITE TREATED
FILL REINFORCED W/ 1 LAYER
INTERIOR FOOTING 1
RETREATED. (PER FBC RESIDENTIAL SIXTH EDITION (2017), SECTIONS R318.1.1, R318.1.2, R318.1.3,
R318.1.4)
6. ELIMINATE OVERPOUR OR MORTAR ACCUMULATION ALONG THE EXTERIOR FOUNDATION
S1.1 OF 6X6 1.4X1.4 W.W.M. OR FIBER SCALE: 1" = 1'-0" s1.1
WINDOW

PERIMETER BEFORE TREATMENT TO ENHANCE VERTICAL PENETRATION OF CHEMICALS. (PER FBC

WINDOW
MESH USE 6 MIL VAPOR BARRIER RESIDENTIAL SIXTH EDITION (2017), SECTION R318.1.5)
7. TREATMENT SHALL BE APPLIED TO ALL EXTERIOR CONCRETE OR GRADE WITHIN 1'-0" OF

16'-11"
SIDEWALLS (W/ 6MIL. VAPOR BARRIER AFTER CONSTRUCTION) (PER FBC RESIDENTIAL SIXTH
3 EDITION (2017), SECTION R318.1.6)
8. NON-CELLULOSE MATERIAL W/ TERMITICIDE SHALL BE USED FOR PROTECTIVE SLEEVES
a3.1
AROUND METAL PIPINGS PENETRATING ON SLAB-ON-GRADE FLOORS. (PER FBC RESIDENTIAL
SIXTH EDITION (2017), SECTION R318.2)
3 1/2" CONC. SLAB WITH FIBER MESH OVER 6 9. POST CONSTRUCTION, ALL LOOSE WOOD AND DEBRIS SHALL BE COMPLETELY REMOVED
MIL. VAPOR BARRIER
FROM UNDER THE BUILDING WITHIN 1'-0" EXCEPT FOR NATURALLY DURABLE OR P.T. WOOD
FOR GROUND CONTACT AND INSTALLED 6" MIN. FROM THE STRUCTURE FOR TERMITE
PROVIDE 1/2" EXPANSION W.H. FINISH FLOOR INSPECTION. (PER FBC RESIDENTIAL SIXTH EDITION (2017), SECTION R318.3)
0'-0"A.F.F.

WINDOW
MATERIAL BETWEEN

43'
43'

HOUSE/PORCH SLAB

12"
WINDOW

REFER TO FOUNDATION NOTE 2'-3"


NO.6 BELOW FOR WALLS

24"
REFER TO FOUNDATION NOTE
NO.4 BELOW FOR SLAB WELL COMPACTED TERMITE
37'

37'
FIN. FLR. TREATED FILL

12"
REFER TO FOUNDATION NOTE GRADE
WINDOW

NO.1 BELOW FOR SLAB 0'-0" A.F.F. ELEV. (-) 0'-12" B.F.F.
(2) #5 REBAR
FIN. FLR. 2" 8"
0'-0" A.F.F.
FOUNDATION NOTES:
PORCH FOOTING 2 1. SLAB-ON-GRADE TO BE 3 1/2" THICK
W/ FIBER MESH ON 6 MIL
VAPOR BARRIER (LAPPED AND TAPED)
SCALE: 1" = 1'-0" s1.1 2. TOP OF SLAB ELEV. + 0'-0"
WINDOW

EXCEPT WHERE NOTED.


3. CJ = 3/16" W. x 1" DP SAW CUT CONTROL

WINDOW
JOINT. CUT SAME DAY AS POUR.
4. PROVIDE TERMITE TREATED CLEAN WELL
WELL COMPACTED FILL UNDER FLOOR SLAB.
RECESS SLAB 1" @ 3 1/2" CONC. SLAB W/ 6X6 - /1.4X1.4 W.W.M. OVER 5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE
WINDOW

SLIDING DOOR 6 MIL VAPOR BARRIER (TYP.) WITH APPLICABLE CODES AND ORDINANCES
#4 NOSE BAR
6. REINFORCE ALL MASONRY WALLS
W/ #5V. @ 48" OC MAX. & ALL CORNERS + JAMBS
FIN. FLR.
0'-0" A.F.F. 3

1'-0"
s1.1

WINDOW

FOUNDATION PLAN
8"

.
MIN
(2) #5 CONT.
11'-8"

4"
30"Х30"Х12D CONC.
FOOTING
W/(3) #5 BARS E.W. (2) #5 CONT.
2

8"
s1.1 33'
8"

STAIR DETAIL 3
SCALE: 3/4" = 1'-0" s1.1

Project No.
FOUNDATION PLAN
SCALE: 1/4" = 1'-0"

ARCHITECT CERTIFIES, TO THE BEST OF HIS KNOWLEDGE, THAT ALL


PLANS AND SPECIFICATIONS COMPLY WITH THE MINIMUM BUILDING
S1.1
CODES.