Design Criteria Wall Types:: Family Area Bedroom 2
Design Criteria Wall Types:: Family Area Bedroom 2
1X WOOD FURRING
7'
WALL TYPE A 1/2" GYP. BD.
3'-0" x 5'-2" 3'-0" x 5'-2" 3'-0" x 5'-2" 3'-0" x 5'-2" 3'-0" x 5'-2" DOORS AND WINDOWS MIN. VALUE = R-5
*FIXED *FIXED *FIXED *FIXED *FIXED
8"
8"
1/2" GYP. BD.
NOTES:
3'-0" x 5'-2" 3'-0" x 5'-2" 3'-0" x 5'-2"
3'-1" 3' 0'-4" 3' 4'-11" 3' 1'-1" 2'-2" 1'-4" 3' 0'-4" 3' 3'-1"
*EGRESS
3'
9'-0" CEILING
O.C. MAX.
CLOSET 1
5'-4"
(*) MEETS EGRESS REQUIREMENT
5'-4"
ACOUSTICAL BATT
4"
18'-5" ON PLANS
10'-5"
8'
8'-7"
BEDROOM 2 WINDOW SIZES
9'-9"
3'
11'-8"
FAMILY AREA WALL TYPE B
3'-0" x 5'-2"
38X63 - 38"W X 63"H SINGLE HUNG
*EGRESS
9'-0" CEILING
4"
3'
1/2" GYP. BD.
3'
0'-4"
*EGRESS
UP
2'-2" 10'-9"
3'
0'-7"
15'-5" O.C. MAX.
2
3'-4"
2'-8"
2'-8"
3'-4"
ACOUSTICAL BATT
11'-4" 3
INSULATION WHERE SHOWN
4 12'-11" ON PLANS
1'-8" 4"
1'-2"
0'-5" 0'-5"
4'-7"
5
5'
4'-7"
12'-11"
4'-7"
1'-8"
6 MAXIMUM SILL HEIGHT FROM FLOOR: 44"
9'-0" CEILING MINIMUM CLEAR OPENING HEIGHT: 24" WALL TYPE C
2'-8"
2'-8"
*EGRESS
11'-4"
8 MINIMUM CLEAR OPENING AREA: 5.7 SQ. FT.
4"
3'
3'
6'-7" 2'-8" 2'-1"
9
0'-7"
13'-3"
10
3'
3'
4"
0'-4"
11'-8"
11
*EGRESS
LEGEND:
37'
37'
9'-0" CEILING
CLOSET 2
12
3'-0" x 5'-2" 3'-0" x 5'-2"
3'
3'
*EGRESS
9'
3'
9'-5"
8'
14 PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYP. BD. A WALL TYPES
BEDROOM 3 15
12'
9'-0" CEILING
4"
3'-8"
0'-4"
16
3'-8"
GENERAL CONSTRUCTION NOTE
*EGRESS
17
3'
3'
2'-2" 10'-9"
18 3'-5" 0'-4" 3'
1'
2'-5" 4"
STAIR DATA: 2 SECTION DETAIL
17 RISERS AT
a1.1
0'-6"
7.64" EACH
2'-5"
2'-8"
10.00" TREADS
2'-8"
2'-8"
2'-8"
2'-8"
2'-8"
1
2'-3" 2'-8" 1' 4'-11" 0'-5" PLAN DETAIL
a1.1
3'-0" x 5'-2" 3'-0" x 5'-2"
*EGRESS
2'-5" 4"
0'-4"
1'
0'-6"
3'
2'-10"
2'-10"
a1.1
2'-6"
11'-9"
4"
2'-2" x 2'-2"
5'-9"
0'-4"
1'-8"
*EGRESS
*TEMP
2'-3"
2'-2"
BATH 2 BATH 1
PRODUCT SUB STATE APPROVAL
3'-8" 2'-6"
8'-4"
3'
3'
5'-2"
3'-8"
3'-8"
STRUCTURAL COMPONENT WOOD CONNECTOR ANCHOR SIMPSON FL11496, FL13326, FL13628, FL13872, FL13904, FL13975, FL15363, FLORIDA PLUMBING CODE SEVENTH EDITION (2020)
3'-5" x 5'-2" FL15730, FL15731, FL15957, FL16230, FL16937, FL17449 FLORIDA EXISTING BUILDING SEVENTH EDITION (2020)
2. 2'-3" x 2'-3" Level
2'-3" x 2'-3"
8"
FLOOR PLAN
8" 2'-4" 2'-3" 4'-4" 4" 3'-11" 33' 2'-2" 7'-4" 3' ROOFING SINGLE PLY ROOFING SYSTEM GAF FL3443.1
FLORIDA ACCESSIBILITY CODE SEVENTH EDITION (2020)
9'-6" 9'-3" 12'-11" ROOFING UNDERLAYMENT OWENS CORNING FL9777.1-R11 NFPA 70, NATIONAL ELECTRICAL CODE (NEC) FIRST EDITION (2020)
Project No.
DOOR PGT INDUSTRIES FL251.9-R30 2. VERIFY WINDOW OPENING DIMENSIONS
EXTERIOR DOORS
W/ MANUFACTURER SIZES.
STRUCTURAL COMPONENT FL158.1-R11 3. DOOR AND WINDOW OPENINGS THAT READ 3080, 20X40, ETC.
LINTELS CASTCRETE ARE 3'-0"x8'-0", 2'-0"x4'-0", ETC.
4. COORDINATE ALL APPLIANCE AND PLUMBING FIXTURE
PANEL WALLS SOFFITS CERTAINTEED CORP. FL13389.1-R5 OPENINGS WITH CABINETRY.
5. DIMENSIONS SHOWN ON PLANS ARE FROM FACE OF STUDS
ROOF VENT ROOF VENT AIR VENT INC. NOA 17-1004.16
WALL DIMENSIONS ARE FROM FACE OF STUD.
6. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH
APPLICABLE CODES AND ORDINANCES.
7. FOR ENERGY CODE COMPLIANCE ALL OPERATION MANUALS
SHALL BE FURNISHED TO OWNER
FLOOR PLAN
SCALE: 1/4" = 1'-0"