Professional Documents
Culture Documents
Premier 300: CT/VT-Operated Energy Meter
Premier 300: CT/VT-Operated Energy Meter
Premier 300: CT/VT-Operated Energy Meter
Application Features
Ÿ CT/VT-operated industrial and commercial billing Ÿ True four quadrant metering
purpose Ÿ Import/Export metering and forwarded metering option
Ÿ Remote data collection for billing and consumption for LT/HT systems
analysis Ÿ Distribution transformer metering events support viz
Ÿ Transformer metering, boundary metering and high and low voltage, under and over load
substation monitoring Ÿ Time of day metering with maximum demand
Benefits registration and automatic billing
Ÿ Backlit LCD display with annunciators for various
Ÿ A wide range for catering to various utilities
critical events
requirement
Ÿ Scroll lock feature for continuous display of a desired
Ÿ High precision metering
parameter on display
Ÿ Revenue protection
Ÿ High-resolution energy display mode for dial test
Ÿ Suitable for doing load analysis and energy audit
Ÿ DLMS protocol for meter reading, with option for remote
reading port
Ÿ Advanced event detection features for voltage, current
and magnetic influences
Ÿ Two metrology LEDs for accuracy testing of different
energy types
Ÿ Meter reading in the absence of mains, using internal
battery
Premier 300
Technical specifications
Electrical
LT HT
Connection type CT-operated CT/VT-operated
Wiring configuration 3-phase 4-wire 3-phase 3-wire, 3-phase 4-wire
Voltage range 230/240 V (P-N) 110 V (P-P), 63.5 V (P-N)
Compliance
Standards IS 14697, IEC 62052-11, IEC 62053-21, IS 15959
Mechanical
Dimensions (W x H x D) 191 x 255 x 82 mm (approx.)
Weight 1.8 kg (approx.)
Enclosure Engineering plastic
Sealing Provision of sealing on main cover and terminal cover
Environmental
Ingress protection IP 51
Temperature -10 ºC to +55 ºC (operating)
-25 ºC to +70 ºC (storage)
Humidity 95% non-condensing RH
Features
Tariff rate registers Up to 8 rate registers, for two energy channels
Maximum Demand Up to 2 types, configurable in 8 registers
Load Survey Up to 90 days load profile for 8 parameters (configurable), with 30 minute
integration period.
Communication Optical port for local communication
Optional RS 232 / RS 485 port on RJ-11 for remote communication.
Optional RS 485 port on RJ-11 with MODBUS
-
- . . .
Premier
CT/VT-operated Energy Meter
Applications Features
CT/VT-operated industrial and commercial billing
? True four-quadrant measurement
?
purpose Time-of-use tariffs and maximum demands
?
Three-phase LV or HV circuits
? Logging of multi-parameter load survey, billing data and
?
Substation monitoring
? events such as power outage and abnormalities
Multi-utility energy accounting
? Easy diagnosis of installation faults via a complete set of
?
instantaneous electrical parameters
Benefits
Optical port for local electronic reading
?
Compact and accurate
?
RS-232 port under the terminal cover for remote
?
Reliable and flexible in use
?
communication
Easy to install; wiring faults can be diagnosed from
?
Programmable pulse outputs
?
instantaneous parameters
Option for pulse inputs for logging external devices for
?
Easy to integrate into an AMR system
?
true multi-utility metering
Premier
Technical specifications
Electrical
LV HV
Connection type CT-operated CT/VT-operated
Wiring configuration 3-phase 4-wire 3-phase 3-wire, 3-phase 4-wire
Voltage range 240/230 V (L-N) 110 V (L-L), 63.5 V (L-N)
Compliance
Standards IEC62052-11, IEC 62053-21, IEC62053-22
Mechanical
Dimensions (W x H x D) 175 x 250 x 55 mm
Weight 1.5 kg (approx.)
Enclosure Engineering plastic
Terminals Nickel-plated brass terminals, with two screws per conductor
Environmental
Ingress protection IP 51
Temperature -10 ºC to +55 ºC (operating)
-25 ºC to +70 ºC (storage)
Humidity 95% non-condensing
Features
Tariff Up to 8 rates
Maximum demand Up to 2, configurable in 4 registers
Load survey 120 parameter-days (up to 4 channels with 30 days each) with 30-minute integration
period. Options for 15/60 minute integration periods
Communication PACT port, RS-232 port (25-pin D-sub)
Pulse I/O (optional) Up to 2 inputs and 4 outputs
Specifications are subject to change without prior notice. (8-10)
. -
- . .