Date : 19 Nov 2020

To: Royal Eagle Electronic Co.,Ltd


Attn: Khin Htay Htay Aung ( Ms. )
From: Htoon (Mr.)/Thu Htet Aung (Mr.)- Kruger Ventilation Myanmar Co.,Ltd
Project: Kruger Fan
Our Quotation Ref. : KVB20-K0513THA-REE00

Given Specification Kruger Fan Model


Selected Selling Price Fan Accessories
Given Fan Specs

Motor Specs Lw Lp Sound Attenuators Spring Isolators


Item Est. Static Qty Fan Fan Ex-Factory, Thailand Remark
Airflow Airflow Est. Static Pressure Fan Type Given Ex-Factory, Thailand Ex-Factory, Thailand
Unit Tag Area Served Pressure Model Size Speed (USD)
(USD) (USD)

Dia.
l/s m3/h Pa l/s m3/h Pa rpm KW/Pole rpm Cl V/Ph/Hz dB(A) dB(A) Unit Price Subtotal Model U/P Qty Amt Model U/P Qty Amt
(mm)

TDA 1000-FV-14AA-7-7/14/AL
Motor Suitable VSD
1 EAF-B1-01&02 Basement Carpark 31700 400 31700 400 2 AFDD AFDD 1000 1450 7.5/4P 1450 H 400/3/50 96 76 2,222.00 4,444.00 KCA 1000-1D 521.00 4 2084.00 SHA-A63 12.00 16 192.00
Motor Operate 250 Deg C For 2 Hrs
Hanger Type
TDA 800-FV-12AA-8-8/18/AL
Motor Suitable VSD
2 EAF-B1-03&04 Basement Carpark 19600 400 19600 400 2 AFDD AFDD 800 1450 5.5/4P 1450 H 400/3/50 90 70 1,627.00 3,254.00 KCA 800-1D 349.00 4 1396.00 SHA-A40 12.00 16 192.00
Motor Operate 250 Deg C For 2 Hrs
Hanger Type

-We can't select Axial Fan Type because your air


3 EAF-B1-05&06 Basement Fire Pump Room 336 150 336 150~250 2 TSK II 160L IFCD AFDD 160 2650 0.121/2P 2650 B 220/1/50 - 59 97.00 194.00 flow is low so we would like to recommend to use
In-Line Centrifugal Duct Fan

-We can't select Axial Fan Type because your air


4 FAF-B1-01&02 Basement Fire Pump Room 336 150 336 150~250 2 TSK II 160L IFCD AFDD 160 2650 0.121/2P 2650 B 220/1/50 - 59 97.00 194.00 flow is low so we would like to recommend to use
In-Line Centrifugal Duct Fan

-We can't select Axial Fan Type because your air


5 EAF-B1-07 Basement MDB Room 780 150 780 150 1 TSK II 250L IFCD AFDD 250 2600 0.14/2P 2600 B 220/1/50 - 59 216.00 216.00 flow is low so we would like to recommend to use
In-Line Centrifugal Duct Fan

TDA 355-L-9AA-5-5/20/AL
6 EAF-B1-08 STP 2900 250 2900 250 1 AFDD AFDD 355 2850 0.55/2P 2900 F 220/1/50 88 67 374.00 374.00 KCA 355-1D 100.00 2 200.00 SHA-A25 12.00 8 96.00
Hanger Type

7 EAF-1-01 LEVEL-1 882 150 882 150~360 1 TSK II 315L IFCD IFCD 315 2600 0.3/2P 2600 B 220/1/50 - 60 227.00 227.00

8 HRV-1B-01 LEVEL-1 1500 250 1500 250 1 Out Of Product HRV HRV - - - - - - - - - -

9 EAF-1-03 LEVEL-1 756 150 756 150 1 TSK II 250L IFCD IFCD 250 2600 0.14/2P 2600 B 220/1/50 - 59 216.00 216.00

1100/ 0.43/4P/ 1100/


CCE 9-7T 4P-1 3SY
10 EAF-2-01 LEVEL-2 1386 150 1386 150 1 IFCD IFCD 252 1150/ 0.5/4P/ 1150/ F 220/1/50 - 51 356.00 356.00
(Medium Speed)
1200 0.56/4P 1200
1100/ 0.43/4P/ 1100/
CCE 9-7 4P-1 3SY
11 EAF-2-02 LEVEL-2 1686 150 1686 150 1 IFCD IFCD 252 1150/ 0.5/4P/ 1150/ F 220/1/50 - 47 356.00 356.00
(Medium Speed)
1200 0.59/4P 1200
1100/ 0.43/4P/ 1100/
CCE 9-7T 4P-1 3SY
12 EAF-3-01 LEVEL-3 1386 150 1386 150 1 IFCD IFCD 252 1150/ 0.5/4P/ 1150/ F 220/1/50 - 51 356.00 356.00
(Medium Speed)
1200 0.56/4P 1200

13 EAF-3-02 LEVEL-3 1008 150 1008 150~300 1 TSK II 315L IFCD IFCD 315 2600 0.3/2P 2600 B 220/1/50 - 60 227.00 227.00

KCE 600M
14 EAF-4-01 LEVEL-4 126 150 126 150 1 CMD CMD 600 890 0.095/4P 890 E 230/1/50 - 48 282.00 282.00
( With Non-Return Flap )

KCE 600M
15 EAF-4-02 LEVEL-4 126 150 126 150 1 CMD CMD 600 890 0.095/4P 890 E 230/1/50 - 48 282.00 282.00
( With Non-Return Flap )

KCE 600M
16 EAF-4-03 LEVEL-4 126 150 126 150 1 CMD CMD 600 890 0.095/4P 890 E 230/1/50 - 48 282.00 282.00
( With Non-Return Flap )

17 EAF-4-04 LEVEL-4 1008 150 1008 150~300 1 TSK II 315L IFCD IFCD 315 2600 0.3/2P 2600 B 220/1/50 - 60 227.00 227.00

TDB-II 450-12AA-7-7/18/AL
18 KEAF-4-01 LEVEL-1 KITCHEN 5500 800 5500 510 1 BIAFDD BIAFDD 450 2850 2.2/2P 2900 F 400/3/50 - - 912.00 912.00 SHA-A25 12.00 4 48.00
Hanger Type

19 EAC-4-01 LEVEL-1 KITCHEN 5500 50 5500 50 1 Out Of Product - - - - - - - - - - - - 0.00 0.00

High Speed
-Throw Distance- 42 m
4500/ Throw Length-24 4619/ -Velocity-0.63 m/s IJB 315 (2S) 2850/ 0.75/2P/ 2850/ 90/ 69/
20 JF-B1-01&02 2 Induced Type Induced Type 315 H 400/3/50 1,117.00 2,234.00 SHA-A25 12.00 16 192.00
2250 ( 0.25 m/s ) 2350 Low Speed Motor Operate 250 Deg C For 2 hrs 1450 0.15/4P 1450 73 52
-Throw Distance-24m
-Velocity-0.51 m/s

High Speed
-Throw Distance- 48 m
6480/ Throw Length-30 7181/ -Velocity-0.79 m/s IJB 355 ( 2S ) 2850/ 1.50/2P/ 2850/ 89/ 68/
21 JF-B1-03 1 Induced Type Induced Type 355 H 400/3/50 1,359.00 1,359.00 SHA-A25 12.00 8 96.00
3240 ( 0.25 m/s ) 3653 Low Speed Motor Operate 250 Deg C For 2 hrs 1450 0.30/4P 1450 70 50
-Throw Distance-30m
-Velocity-0.62 m/s

High Speed
-Throw Distance- 42 m
4500/ Throw Length-24 4619/ -Velocity-0.63 m/s IJB 315 (2S) 2850/ 0.75/2P/ 2850/ 90/ 69/
22 JF-B1-04 1 Induced Type Induced Type 315 H 400/3/50 1,117.00 1,117.00 SHA-A25 12.00 8 96.00
2250 ( 0.25 m/s ) 2350 Low Speed Motor Operate 250 Deg C For 2 hrs 1450 0.15/4P 1450 73 52
-Throw Distance-24m
-Velocity-0.51 m/s

High Speed
-Throw Distance- 48 m
6480/ Throw Length-30 7181/ -Velocity-0.79 m/s IJB 355 ( 2S ) 2850/ 1.50/2P/ 2850/ 89/ 68/
23 JF-B1-05 1 Induced Type Induced Type 355 H 400/3/50 1,359.00 1,359.00 SHA-A25 12.00 8 96.00
3240 ( 0.25 m/s ) 3653 Low Speed Motor Operate 250 Deg C For 2 hrs 1450 0.30/4P 1450 70 50
-Throw Distance-30m
-Velocity-0.62 m/s

Total Quantity = 28 18,468.00 10 3,680.00 84 1,008.00


Less Discount 25% & 5% (Fans) 5,309.00 Less 10% 100.00
Subtotal Amount for MV Fan 13,159.00 3,680.00 908.00

Total Amount of MV Fans, Ex-factory, Thailand (USD) 13,159.00

KRUGER Ventilation (Myanmar) Co.,Ltd


Room No. F-21, Thiri Yandanar Whole Sale Market , (Htawunbe) Toe Chae Ward, North Okkalapa Township, Yangon, Myanmar
Tel. +95 9763141081 to 3
Fan Accessories
Sound Attenuators 3,680.00
Spring Isolators 908.00
Total amount of fan accessories (USD) 4,588.00

Total Amount of Ex-factory, Thailand (USD) 17,747.00


Notes:

1) The above quoted consist of the followings:-


TDA-L : Kruger direct drive axial fan consisting of long casing with hanger support bracket, motor and impeller. Material of casing in galvanised steel sheet.
Impeller consists of aluminium fan blades with manually adjustable pitch.
Motor shall be foot-mounted, totally enclosed type, IP 55, Class F insulation. Brand shall be Kruger or equivalent.
TDA-FV : Kruger direct drive vane axial fan consisting of casing with hanger support bracket, motor and impeller. Material of casing in galvanised steel sheet.
Impeller consists of aluminium fan blades with manually adjustable pitch. Suitable for continuous operation for 250oC for 2 hours.
Motor shall be foot-mounted, totally enclosed type, IP 55, Class H insulation. Brand shall be Kruger or equivalent.
TSK II : Kruger direct drive in-line centrifugal duct fan c/w external rotor motor. The casing is manufactured from pre-galvanised steel.
Motor is induction type with external rotor on ball bearings, IP 44, Class B insulation.
TDB : Kruger direct drive bifurcated axial fan consisting of casing with mounting feet, motor and impeller. Material of casing in painted steel sheet with polyester powder coating.
Impeller consists of aluminium fan blades with manually adjustable pitch.
Motor shall be foot-mounted, totally enclosed type, IP 55, Class F insulation. Brand shall be Kruger or equivalent.
TDA-V : Kruger direct drive vane axial fan consisting of casing with hanger support bracket, motor and impeller. Material of casing in galvanised steel sheet.
Impeller consists of aluminium fan blades with manually adjustable pitch.
Motor shall be foot-mounted, totally enclosed type, IP 55, Class F insulation. Brand shall be Kruger or equivalent.
CCE : Kruger direct drive in-line cabinet fan consisting of cabinet, motor and DIDW forward curve fan. Material of casing in galvanised steel sheet.
Motor is induction type with external shaft, IP20, Class F insulation.
KCE : Kruger direct drive ceiling mount fan. Impeller and casing are made of plastics.
IJB : Kruger direct drive jet fan consisting of mounting bracket, inlet and outlet silencer, inlet and outlet protection net, motor and impeller. Material of casing in galvanised steel sheet.
Impeller consists of aluminium fan blades with fixed pitch. Suitable for continuous operation for 250 oC for 2 hours.
Motor shall be foot-mounted, totally enclosed type, IP 55, class H insulation. Brand shall be Kruger or equivalent.
2) The above quoted exclude all other accessories except those indicated.
3) The above sound level stated (SPL) is sound pressure level in free field at 3M from the fan. Lw refers to the sound power level in dBA.
4) Prices quoted exclude commercial tax 5% .

Delivery : approx. 4 -6 weeks Ex-factory Thailand upon order confirmation; subject to stock & motor availability.
:approx;8-12 weeks Ex-Factory Thailand for KCE Model,TSK II Model,MTD Silent Model, APM Model & Class-H upon order confirmation; subject to stock & motor availability.
Terms : T/T Before Shipment.
Validity : 30 days.

KRUGER Ventilation (Myanmar) Co.,Ltd


Room No. F-21, Thiri Yandanar Whole Sale Market , (Htawunbe) Toe Chae Ward, North Okkalapa Township, Yangon, Myanmar
Tel. +95 9763141081 to 3