Table 1: Tests requested by Customer

S.No Test Case Basic Standard Applicability


Voltage dips ,short interruptions and Applicable since the Current
1 voltage variations immunity tests for IEC 61000-4-11 drawn by ceiling fan not more
currents less than 16A than 500 mA
2 Inter Harmonics IEC 61000-4-13 Applicable

3 Voltage fluctuation immunity test IEC 61000-4-14 Applicable


Ripple on DC Input Power Port Not Applicable since the EUT is
4 IEC 61000-4-17
Immunity test operating on 230V 50Hz
5 Unbalance IEC 61000-4-27 Applicable
Variation of power frequency
6 IEC 61000-4-28 Applicable
immunity test
Voltage Dip, Instantaneous power Not Applicable since the EUT is
7 IEC 61000-4-29
failure and Voltage Variation in DC operating on 230V 50Hz
Voltage dips ,short interruptions and Not Applicable since the Current
8 voltage variations immunity tests for IEC 61000-4-34 drawn by ceiling fan not more
currents exceeding 16A than 500 mA

Table 2: Additional tests required in general based on the EMC Directive

S.No Test Case Product Standard Basic Standard


1 Conducted Emission CISPR 32 (CISPR 16-2-3)
2 Radiated Emission CISPR 32 (CISPR 16-2-3)
3 Harmonic Current Emissions IEC 61000-3-2
voltage changes, voltage fluctuations
4 IEC 61000-3-3
and flicker
Electrostatic discharge immunity CISPR 14-1,
5 IEC 61000-4-2
test CISPR 14-2.
Radiated, radio-frequency IEC 61000-3-2 &
6 IEC 61000-4-3
electromagnetic field immunity test IEC 61000-3-3
7 fast transient/burst immunity test IEC 61000-4-4
8 Surge immunity test IEC 61000-4-5
Immunity to conducted
9 disturbances, induced by radio- IEC 61000-4-6
frequency fields
Power frequency magnetic field
10 IEC 61000-4-8
immunity test

Note: If Ceiling fan contains the light, then CISPR 15 & IEC 61547 will be applicable.