Foundation-1.5 SA & DA

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

650

Rev. Date Revision Description


4 NOS HOLE Ø26 THRU. No.
R1 15-03-2022 FINAL DESIGN
ON 275 P.C.D. EQUISPACED
T1 - (Ø12 -8 NOS.)
650

T2 - (Ø8 190 C/C)

300 SQ.
Ø180
SECTION B-B
Customer :
650 4 NOS. M24 x 750LG. Patna Smart City Ltd.
FOUNDATION J. BOLTS
ON 275 P.C.D. System Integrator :
100

F.G.L. F.G.L.
L&T Smart World
3 THK. Safe & Smart Cities | Communication
Ø50 PVC PIPE FOR TEMPLATE
SCALE 1 : 5
Project Name :
CABLE ENTRY
Selection of Master Systems Integrator (MSI) to Design,
Development, Implementation, Operations & Maintenance of
Command and Control Centre (CCC), CCTV Surveillance, Smart
B B
GENERAL NOTES :- Traffic Solution and Integration of various ICT components with
Integrated Command and Control Center Platform (ICCC)
1. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE SPECIFIED.
T1 - Ø12 - 8 NOS 2. MATERIAL & CONSTRUCTION TO BE IN ACCORDANCE WITH IS : Drawing No. Rev.
456 POB-LE21M915-TEDD-ED-0500-0323 1
1350

3. THE CONCRETE GRADE FOR FOUNDATION & OTHER WORKS


Document Name:
1250

SHALL BE MIX M25


T2 - Ø8 AT 190 C/C 4. IT IS ASSUMED THAT SOIL TYPE IS NORMAL HARD DRY SOIL CCTV Surveillance Pole Foundation for 1.5 mtr Single & Double arm
A. THE SOIL BEARING CAPACITY IS 10 T/M² AT 1.25M BELOW G.L.
B. ANGLE OF REPOSE 30°
Scale : 1:1000 Sheet : 001/001
C. DENSITY OF SOIL 1.85 T/M³ PDMC's Approval with Stamp Signature & Date
D. BASIC WIND SPEED : 47 M/SEC.
5. REINFORCEMENT SHALL BE OF GRADE Fe415 COMPLYING WITH
IS : 1786-1985
6. CLEAR COVER TO MAIN REINFORCEMENT AT END OF MAIN BARS
COLUMN : 40m. Client's Approval with Stamp Signature & Date
7. DEVELOPMENT LENGTH FOR TENSION LDT=50 TIMES THE DIA OF
BAR.
8. FOR ANY OTHER DETAILS CLAUSES OF IS-456, SP-34 & SP-23
SHALL BE REFERRED.
650 9. IT IS ASSUMED THAT WATER TABLE IS NOT FOUND, IF FOUND
PLEASE APPROACH TLL FOR REVISED DESIGN DRAWING. Pre. By Rew. By Apr. By
ELEVATION
HL MP SP