PT BETON ELEMENINDO PERKASA

JTB2 - PERTAMINA
BEARING CALCULATION (Precast Beam to Corbel)
07 Agustus 2019 | R0 | ist
DATA
Dimension :
L axis = 7 m (ctc of column to column) Precast Beam :
wb = 0,05 m (width of bearing) b= 0,35 m
B= 1 m (width of Column & Corbel) h= 0,40 m
L in = 6 m (netto column to column) w = 2.016,0 kg
end beam width = 0,15 m (width of bearing) P = 0.5*w = 1.008,0 kg

Material Properties :
Corbel K- 250 kg/cm2 (cube) Precast Beam Precast Beam

f'c = 20,11 Mpa (Cylinder) Action wb


Beam K- 250 kg/cm2 `
Load
Cracking
f'c = 20,11 MPa beam
Cracking
Reaction Bearing
Loading (Bearing) Corbel

g= 2400 kg/m3 (concrete specific gravity)


B
h top. = 0,6 m (heigh of topping)
gravity (g) = 9,81 m/s2

CALCULATION
Reviewed each 1m Column Corbel
Force F = 0.5 x weigt of precast beam
Force F = 1.008,00 kg
Force F = 9.888,48 N

Bearing Capacity at wall :


stu = 0,45 x K (MPa --> allowable bearing)
stu = 9,05 MPa
Area A = end width beam x wb
Area A = 7.500,00 mm2
Stressing = F / A
Stressing = 1,32 MPa < 9,05 MPa OK 686,3%
Safety Factor = 6,86

Shear at concrete corbel :


o
shear angle = 60 .
p = wb / cos a.
p= 100,00 mm (length of shear)
fVc = 0.6 x (1/6) x (√f'c) x 1000 x p
fVc = 44.843,33 N
Shear V = Force F
V= 9.888,48 N
Conclusion = OK 453,5%
Safety Factor = 4,53

ps : calculating is assume with no rebar


END / FINISH