Solenoid operated spool valve

Solenoid operated spool valve


NG6
Flange construction ISO 4401-03
◆◆4/2-way impulse valve
◆◆4/3-way with spring centred mid position x II 2 G Ex db IIC T6, T4
◆◆4/2-way with spring reset x II 2 D Ex tb III C T80 °C, T130 °C
◆◆Qmax = 80 l/min x I M2 Ex db I Mb
◆◆pmax = 350 bar Class I Division 1
Class I Zone 1

   
DESCRIPTION  ​ APPLICATION  ​
Direct operated solenoid spool valve with 4 connections in 5 cham- These valves are suitable for applications in explosion-hazard
ber design. With the solenoids deenergised, the spool is held in the areas, open cast and also in mines. Spool valves are mainly used for
center position by the spring (4/3), or switched back to the offset controlling direction of movement and stopping of hydraulic cylin-
position (4/2). With the impulse spool (4/2), the spool is held in the ders and motors. The direction of movement is determined by the
switching position by the detent. The pressure tight encapsulated position of the spool and its symbol. ​​​​​​
Ex-protection solenoid coil prevents an explosion on the inside
penetrating to the outside as well as an ignitable surface tempera-
ture. ​​​​​

CERTIFICATES  ​ ACTUATION  ​

Surface Mining Standard Z604 Actuation Switching solenoid, wet pin push type,
-25 °C to… -40 °C to… pressure tight
ATEX x x x x Execution MKY45 / 18x60 (data sheet 1.1-183)
IECEx x x x x MKU45 / 18x60 (data sheet 1.1-184)
Connection Cable gland for cable Ø 6,5…14 mm
CCC x x x x
EAC x x x x Attention! The UL execution is always supplied without cable
gland
Australia x x x x
MA x x
UL / CSA x x x

The certificates can be found on www.wandfluh.com

SYMBOL  ​

AB3 AB1 AB2
A B A B A B

a b a b a b
a b a b a b
P T P T P T
 ​

ACB AC1 CB2
A B A B A B

a o b a b a b
a b a b a b
P T P T P T
 ​

ADB AD1 DB2
A B A B A B
o b a
a b a b
a b a b a b
P T P T P T
​ 

www.wandfluh.com  Illustrations are not binding  Data subject to change 1/5 Edition: 21 05  1.3-34 E
Solenoid operated spool valve

SYMBOL  ​

BEA BE1 EA2
A B A B A B

a o b a b a b
a b a b a b
P T P T P T
 ​

AFB AF1 FB2
A B A B A B
o b a
a b a b
a b a b a b
P T P T P T
 ​

AGB AG1 GB2
A B A B A B
o b a
a b a b
a b a b a b
P T P T P T
​ 

TYPE CODE  ​
WD Y F A06 - - / / - #
Spool valve direct operated

Explosion proof execution Ex d

Flange construction

International standard interface ISO, NG6

Designation of symbols acc. to table

Nominal voltage UN 12 VDC G12 115 VAC R115


24 VDC G24 230 VAC R230

Ambient temperature up to:


Nominal power PN 9W L9 40 °C or 90 °C
15 W L15 70 °C
17 W L17 70 °C (only UL / CSA)

Certification ATEX, IECEx, CCC, EAC


Australia AU UL / CSA UL
MA MA

Sealing material NBR


FKM (Viton) D1
NBR -40 °C y-Z604 (only with 15 W)

Design index (subject to change)


1.3-34

www.wandfluh.com  Illustrations are not binding  Data subject to change 2/5 Edition: 21 05  1.3-34 E
Solenoid operated spool valve

GENERAL SPECIFICATIONS  ​ HYDRAULIC SPECIFICATIONS  ​


Designation 4/2-, 4/3-spool valve Working pressure pmax = 350 bar
Construction Direct operated Tank pressure pT max = 200 bar
Mounting Flange construction Maximum volume flow Qmax = 80 l/min, see characteristics
Nominal size NG6 according to ISO 4401-03 Leakage oil See characteristics
Actuation Ex-protection switching solenoid Fluid Mineral oil, other fluid on request
Ambient temperature Operation as T6 Viscosity range 12 mm2/s…320 mm2/s
-25…+40 °C (L9) Temperature range Operation as T6
Operation as T4 fluid NBR -25…+40 °C (L9)
-25…+90 °C (L9) FKM -20…+40 °C (L9)
-25…+70 °C (L15 / L17) Operation as T4
-40…+70 °C (L15 / L17) NBR -25…+70 °C (L9 or L15 / L17)
Weight 2,8 kg (1 solenoid) FKM -20…+70 °C (L9 or L15 / L17)
4,6 kg (2 solenoids) NBR 872 -40…+70 °C (L15 / L17)
MTTFd 150 years Contamination Class 20 / 18 / 14
efficiency
Filtration Required filtration grade ß 10…16 ≥ 75,
see data sheet 1.0-50

ELECTRICAL SPECIFICATIONS  ​ MANUAL OVERRIDE  ​


Protection class IP65 / 66 / 67 HB6 as standard
Relative duty factor 100 % DF Optionally: HN (K)
→ see data sheet 1.1-311
Switching frequency 12'000 / h
Voltage tolerance ± 10 % with regard to nominal voltage
Standard nominal 12 VDC, 24VDC, 115 VAC, 230 VAC SURFACE TREATMENT  ​
voltage AC = 50 to 60 Hz ± 2 %, with built-in ◆◆The valve body is painted with a two component paint
two-way rectifier ◆◆The armature tube, the slip-on coil and the plug screw are
Standard nominal 9 W, 15 W, 17 W zinc-nickel coated
power
Temperature class Nominal power 9 W: T1…T6
Nominal power 15 W / 17 W: T1…T4
COMMISSIONING  ​
Note! Other electrical specifications see data sheet 1.1-183 Attention! The solenoid coil must only be put into operation, if the
and 1.1-184 requirements of the operating instructions supplied are
observed to their full extent. In case of non-observance,
no liability can be assumed.

www.wandfluh.com  Illustrations are not binding  Data subject to change 3/5 Edition: 21 05  1.3-34 E
Solenoid operated spool valve

PERFORMANCE SPECIFICATIONS  ​
Oil viscosity u = 30 mm2/s

p = f (Q) Performance limits L15 / L17 p = f (Q) Performance limits L9


Measured with nominal voltage -10% at 50 °C Measured with nominal voltage -10% at 40 °C
Execution L9 90 °C on request
p [bar] AFB AB1 / AB3 / ACB p [bar] BEA AGB
350 350
K4105 K4106

300 AGB 300 AB1/AB3

250 250 ACB


AFB
200 ADB 200
150 150
ADB
100 100
BEA
50 50
0 0
0 10 20 30 40 50 60 70 80 Q [l/min] 0 10 20 30 40 50 60 70 80 Q [l/min]

​  ​ 

Δp = f (Q) Pressure drop volume flow characteristic Flow direction


∆p [bar] Symbol P-A P-B P-T A-T B-T
5
30
K0171

AB1 2 2 - 1 1
1
25
AB3 2 2 - 1 1
20 2

15 3 ACB 2 2 - 1 1
10 4 ADB 2 2 - 3 3
5 BEA 2 2 5 2 2
0
AFB 4 4 - 3 3
0 10 20 30 40 50 60 70 80 Q [l/min]
AGB 4 4 - 1 1
​ 

QL = f (Q) Leakage volume flow characteristics


per control edge
Q [cm3/min]
Note! With the L15 / L17 execution for ambient temperatures
150
K0232_3

up to 70 °C, the performance specifications have been


120 evaluated with an ambient temperature of 50 °C
90
60 Attention! For valves for the temperature ranges „-40 °C to…”
30
(Z604) the leakage volume flow can be up to eight times
higher.
0
0 50 100 150 200 250 300 350 p [bar]
AB3/AB1/ACB/ADB/AFB/AGB
BEA

​ 

www.wandfluh.com  Illustrations are not binding  Data subject to change 4/5 Edition: 21 05  1.3-34 E
Solenoid operated spool valve

DIMENSIONS  ​
4/3-way spool valve (spring centring) 4/2-way spool valve (spring reset)
4/2-way spool valve (impulse)
110
MD=5.2Nm
9.5
5.5

8
94.3
15
MD= 5.5Nm

49
41
23.5
10
245.9 12 17 18 10 18 70 40
MD= 9Nm MD= 50Nm
Dimensions of the solenoid coil, refer to data sheet 1.1-183 and 1.1-184 ​
60 5

89 68 12.6

169.6

​ 

HYDRAULIC CONNECTION  ​ PARTS LIST  ​


​ Position Article Description
17.8
10 263.6... Solenoid coil MK.45 / 18 x 60
T
12 154.2603 Knurled nut Ex M18 x 1,5 x 18
A B
15 253.8001 HB6 Manual override „-25 °C to…”
32.5
31

21

253.8025 HB6-Z604 Manual override „-40 °C to…”


P 17 160.2251 O-ring ID 25,07 x 2,62 (NBR)
21.5
18 160.2170 O-ring ID 17,17 x 1,78 (NBR)
40.5

​  40 239.2205 Socket head screw M20 x 1


70 160.2093 O-ring ID 9,25 x 1,78 (NBR) „-25 °C to…”
160.7092 O-ring ID 9,25 x 1,78 (NBR) „-40 °C to…”
160.6092 O-ring ID 9,25 x 1,78 (FKM)
SEALING MATERIAL  ​
NBR or FKM (Viton) as standard, choice in the type code 110 111.1080 Cable gland M20 x 1,5

ACCESSORIES  ​ INSTALLATION NOTES  ​

Fixing screws Data sheet 1.0-60 Mounting type Flange mounting


Threaded subplates Data sheet 2.9-30 4 fixing holes for
socket head screws M5 x 50
Multi-station subplates Data sheet 2.9-60
Mounting position Any, preferably horizontal
Module type manifold blocks Data sheet 2.9-100
Tightening torque Fixing screws MD = 5,2 Nm (screw
Technical explanations Data sheet 1.0-100 quality 8.8, zinc coated)
Filtration Data sheet 1.0-50 MD = 9 Nm knurled nut
Relative duty factor Data sheet 1.1-430
Note! The length of the fixing screw depends on the base
material of the connection element.

Attention! For stack assembly please observe the remarks in the


STANDARDS  ​
operating instructions
Explosion protection Directive 2014 / 34 / EU (ATEX)
Flameproof enclosure EN / IEC / UL 60079-1, 31
Cable entry EN 60079-0, 1, 7, 15, 31
Mounting interface ISO 4401-03
Protection class EN 60 529
Contamination ISO 4406
efficiency Wandfluh AG Postfach CH-3714 Frutigen
Tel. +41 33 672 72 72  Fax +41 33 672 72 12  sales@wandfluh.com

www.wandfluh.com  Illustrations are not binding  Data subject to change 5/5 Edition: 21 05  1.3-34 E