Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 3

Brine New Thinking

Horizontal Vertical Crystallizer (HVC)

Solar Coil at 65 C (180 meters long x 1080 sq.m.


Horizontal Vertical Crystallizer 150 sq.m.
Total Area 1230 sq.m.

Temperature 65 Celsius
Volume 10 liters
60 seconds
60 minutes
6 hours
Total Volume 216,000.00 liters ** this is one pass (for experimentation) vs. wh
24% What is the salt content?
51,840.00 kg.
20% How many percent can we actually convert into
10,368.00 kg. Compare this to a white basin; and

8.43 kg. / sq.m. per day


800 sq.m.
6,743.41 kg. per sq.m. per day using a HVC

SP# 1-1 800 sq.m. output per day 1.375 kg. per sq.m.

613% percent increase of production per sq.m.


or experimentation) vs. what is the brine volume stationary in a crystallizer pond?

an we actually convert into salt? (for experimentation)


this to a white basin; and a CA and SP crystallizer
CRYSTALLIZER DATA

SP Crystallizer
Flooding depth 2.5 cm.
Area: 80m*10m. Of SP#1-1 800 sq.m.
Brine volume 20 cu.m.
20000 liters
24% salt content
4800 kg. in salt content

Salt harvested per day 100 baskets


Kg. per basket 11 kg.
Salt Crystallized 1100 kg.

Salt Crystallized 6% is converted from brine to salt

Salt Crystallized 1.375 kg. per sq.m. per day