● IN CONCEPT OF LEARNING AND ● WE ALSO STUDIED ABOUT THE CONVENTION, CONVECTION AND CONDUCTION OF

ACKNOWLEDGING THE CLIMATIC RESPONSIVE HEAT TRANSFER AND CLIMATIC CHANGE OVER EVOLUTION
ARCHITECTURE, AT THE STARTING WE HAD BEEN
INTRODUCTION TO THE SUBJECT BY BASIC ● THE WHOLE COURSE MOTO WAS TRYING TO STUDY OF CLIMATIC ANALYSIS OF A
VALUE OF HOW CLIMATE HAS A MAJOR PARTICULAR LOCATION THAT WE ARE GIVEN TO CHOOSE FROM ENERGYPLUS
IMPACT ON ARCHITECTURE AND THAT HOW WE SOURCE AND DISCOVER THE PARAMETERS & EXTRACTING THE DATA FROM
NEED TO TAKE MESURE BEFORE ANALYSIS THE CLIMATE CONSULTANT V6.0 SOFTWARE FOR DRY BULB TEMPERATURE, DEW
PURPOSE OF ARCHITECTURE DESIGNING. POINT, WIND DIRECTION, WIND SPEED, RELATIVE HUMIDITY, UNDER THE PERIOD
OF ANNUAL DURATION.FOR MY CHOSEN CITY OF VERAVAL, GUJRAT.

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 14.01.2022
SHOW & TELL INITIATION- SEMESTER : 4

ABSTRACT UNDERSTANDING OF SCALE :


SCHOOL OF ARCHITECTURE,
CLIMATOLOGY CHRIST UNIVERSITY
SHEET NO. 1 (DEEMED TO BE UNIVERSITY)
AS A GROUP PRESENTATION, ALL WE
WORKED ON THE HISTORY OF
TOPOGRAPHY CLIMATIC CHANGES
OVER PERIOS, CLIMATE CAUSING
FACTORS OF THE CITY UNDER WHAT
ALL IMPACTS IT WHEN TO CHANGE
THE BEAUTIFUL NATURAL PERIOD
DISASTERS IT GONE.
WE ALSO MAKE ANALYSIS OF
FACTORS CAUSING IMPACT INTO A
IMAGE COLLAGE

CITY OF LAVASA
WE RECREATED A SCENARY OF THE
PLACE MAKING A COLOUR PITS
COLLAGE IN DIGITAL SHOWING THE
HOW A SAME LANDSCAPE CHANGE
DRASTICALLY OVER SHORT TEM OF
DECADES.
KNOWING WHETHER EITHER THE
CLIMATE CHANGES MADE IMPACT
ON CHANGE IN ARCHITECTURE &
CONSTRUCTION STYLE OR THE
CONSTRUCTION MADE THE CLIMATIC
CHANGES.

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 1.02.2022
RELATIONSHIP BETWEEN NATURE & SEMESTER : 4

BUILT ENVIRONMENT SCALE :


SCHOOL OF ARCHITECTURE,
CHRIST UNIVERSITY
SHEET NO. 2 (DEEMED TO BE UNIVERSITY)
STUDY OF PASSIVE
TECHNIQUES
HEREBY LEARN WHAT ALL WAYS OF USING
PASSIVE TECHNIQUES IN BOTH
CONTEMPORARY AND HISTORICAL
STRUCTURE. STUDYING AND COMPARING
THE BOTH DIFFERENT STRUCTURE HOW THEY
HAVE BEEN EVOLUTION OF USE OF PASSIVE
TECHNIQUES IN A STRUCTURE. AS A TEAM
WORK, WE SPOKE ABOUT VARIOUS PASSIVE
TECHNIQUES SOME ARE LIKE HIGH
CORRIDORS, NATURAL VENTILATIONS,
COURTYARDS, SKYLIGHTS AND PERGOLAS
IN CONTEMPORARY IIM BANGALORE
STRUCTURE AND SOME ARE IN HISTORICAL
CHOWMAHALLA PALACE LIKE THEY
FOCUSED ON NATURAL VENTILATIONS,
COURTYARDS, WATERBODYS, CROSS
VENTILATIONS, PROVIDING LARGE
OPENINGS AND WINDOW AROUND THE
STRUCTURE

NAME & ROLL NO. : RISHIGANESH S N 2061709


PARAMETRIC ANALYSIS OF PASSIVE DATE : 12.02.2022 SEMESTER : 4

TECHNIQUES & SUSTAINABLE FEATURES


SCALE :
/ SYSTEMS IN IIM BANGALORE & SCHOOL OF ARCHITECTURE,
CHRIST UNIVERSITY
CHOWMAHALLA PALACE BUILDINGS SHEET NO. 4 (DEEMED TO BE UNIVERSITY)
CLARIFLOCCULATOR
WASTEWATER TREATMENT
CHOOSING ONE TYPE OF WASTE
WATER TREATMENT FROM ANY ONE
FROM THREE CATEGORY WHICH ARE
PRIMARY TREATMENT, SECONDARY
TREATMENT, TERTIARY TREATMENT
METHODS

WE FOUR AS A GROUP, STUDIES


ABOUT CLARIFLOCCULATOR
TREATMENT WHICH IS A BOTH
PRIMARY & SECONDARY TREATMENT.

CALCULATING FOR OUR OWN


DEVADAN HALL (BOYS HOSTEL) OF
1000 PERSON’S WASTEWATER PER
DAY TO HOLD AND FORMULATING
THE SIZE AND BUILD AREA OF
CLARIFLOCCULATOR

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 25.03.2022
DESIGN OF CLARIFLOCCULATOR SEMESTER : 4

WASTE WATER TREATMENT PLANT SCALE :


SCHOOL OF ARCHITECTURE,
FOR DEVADAN HALL (BOYS HOSTEL) CHRIST UNIVERSITY
SHEET NO. 5 (DEEMED TO BE UNIVERSITY)
DESIGN STUDIO & FURNITURE LAYOUT
DESIGN STUDIO TECHNICAL DRAWINGS
CONDITIONS

ILLUMINANCE WHILE CALCULATING


& THEN NOTING DOWN THE DATA
FROM USE OF ‘LUX METER’ BY THESE
PARAMETERS :

● KEEPING THE OPENINGS LIKE


DOORS AND WINDOWS OPEN
● KEEPING THE FOLDABLE DOORS IN
BETWEEN TWO STUDIOS OPEN DESIGN STUDIO SECTIONAL VIEW
● KEEPING ALL THE CEILING LED
LIGHTS ON
● PLOTTING NINE EQUAL POINTS IN
THE DESK
● PLACING THE DEVICE &
COLLECTING DATA ONE EACH
POINT CORNERS & CENTRE OF THE
DESK
● FORMULA USED : RI = L x W
hu(L + W)

DESIGN STUDIO PLAN

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 23.04.2022 SEMESTER : 4
CALCULATING AVERAGE
ILLUMINANCE LEVEL AT DESK SCALE :
SCHOOL OF ARCHITECTURE,
HEIGHT BASED ON ROOM INDEX SHEET NO. 6A
CHRIST UNIVERSITY
(DEEMED TO BE UNIVERSITY)
ILLUMINANCE LEVEL FOR WORK SPACE - ZONE A

HERE BY WE CALCULATE THE NINE DIFFERENT CORNERS & CENTRE IN A DESK, EACH DESK NAMING IN ALPHABETS.
CALCULATING LUX MIN. VALUE, PEAK VALUE, IN THE DEVICE AND THE CALCULATING THE AVERAGE VALUE.

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 23.04.2022 SEMESTER : 4
CALCULATING AVERAGE
ILLUMINANCE LEVEL AT DESK SCALE :
SCHOOL OF ARCHITECTURE,
HEIGHT BASED ON ROOM INDEX SHEET NO. 6A.1
CHRIST UNIVERSITY
(DEEMED TO BE UNIVERSITY)
ILLUMINANCE LEVEL FOR LECTURE SPACE AREA - ZONE B

HERE BY WE CALCULATE EACH FURNITURE CHAIR PLOT SPACES NAMING IN NUMBERS.


CALCULATING LUX MIN. VALUE, PEAK VALUE, IN THE DEVICE AND THE CALCULATING THE AVERAGE VALUE.

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 25.04.2022 SEMESTER : 4
CALCULATING AVERAGE
ILLUMINANCE LEVEL AT DESK SCALE :
SCHOOL OF ARCHITECTURE,
HEIGHT BASED ON ROOM INDEX SHEET NO. 6B
CHRIST UNIVERSITY
(DEEMED TO BE UNIVERSITY)
ILLUMINANCE LEVEL FOR LECTURE SPACE AREA - ZONE B
AVERAGE ILLUMINANCE CALCULATION :

En = En1 + En2 + …..


N
FOR ZONE-A
EA = 174.92+266.33+160.7+184.62+162.88+187.85+176.35+170.12+236.22+252.83+319.3 = 208.39
LUX-MIN 11
EA = 170.81+273.22+164.15+185.9+162.45+191.64+216.08+169.75+241.33+255.5+327.33 = 214.38
PEAK VALUE 11

FOR ZONE-B
EB = 597.42 + 557.33 + 542.5 + 269.5 + 505.83 + 364.25 + 441.5 = 468.29
LUX-MIN 7
EB = 608.57 + 605 + 541.33 + 292.41 + 553 + 376 + 468 = 492.04
PEAK VALUE 7

BOUNDARY CONDITIONS
ILLUMINANCE WHILE DOING / TAKING READING BY USING
LUX METER FOLLOWING THE CONDITION BELOW:
● KEEPING THE DOORS OPEN
● KEEPING THE WINDOW OPEN
● KEEPING THE FOLDABLE DOOR IN BETWEEN THE CLASSES OPEN
● KEEPING ALL THE CEILING LIGHT FIXTURES ON
● DEVICE PLACED BASED ON THE FOLLOWING DRAWING ABOVE
COMPARISON BETWEEN TOTAL AVERAGE ILLUMINANCE OF
● FORMULA FOR RI = L x W ZONE-A & ZONE-B

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 25.04.2022 SEMESTER : 4
CALCULATING AVERAGE
ILLUMINANCE LEVEL AT DESK SCALE :
SCHOOL OF ARCHITECTURE,
HEIGHT BASED ON ROOM INDEX SHEET NO. 6B.1
CHRIST UNIVERSITY
(DEEMED TO BE UNIVERSITY)
SOLAR DAYLIGHT ILLUMINANACE LEVEL FOR STUDIO SPACE - ZONE A

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 27.04.2022 SEMESTER : 4
CALCULATING AVERAGE
ILLUMINANCE LEVEL AT DESK SCALE :
SCHOOL OF ARCHITECTURE,
HEIGHT BASED ON ROOM INDEX SHEET NO. 6C
CHRIST UNIVERSITY
(DEEMED TO BE UNIVERSITY)
CALCULATION OF SOLAR DAYLIGHT ILLUMINANCE FOR STUDIO SPACE
AVERAGE ILLUMINANCE CALCULATION :

En = En1 + En2 + …..


N
FOR ZONE-A
EA = 110.55 + 122.22 + 227.33 + 208.55 + 122.22+104.76 + 70.11 + 68.8 + 74.47 + 98.61 + 119.66 = 120.66
LUX-MIN 11
EA = 112.22 + 127.55 + 252.33 + 215.11 + 130.22 + 107.02 + 71.27 + 73.70 + 77.53 + 109.25 + 127.5 = 214.38
PEAK VALUE 11

BOUNDARY CONDITIONS
ILLUMINANCE WHILE DOING / TAKING READING BY
USING LUX METER FOLLOWING THE CONDITION
BELOW:
● KEEPING THE DOORS OPEN
● KEEPING THE WINDOW OPEN
● KEEPING THE FOLDABLE DOOR IN BETWEEN THE CLASSES OPEN
● KEEPING ALL THE CEILING LIGHT FIXTURES ON
● DEVICE PLACED BASED ON THE FOLLOWING DRAWING ABOVE
● FORMULA FOR RI = L x W

TOTAL AVERAGE ILLUMINANCE OF ZONE-A

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 28.04.2022 SEMESTER : 4
CALCULATING AVERAGE
ILLUMINANCE LEVEL AT DESK SCALE :
SCHOOL OF ARCHITECTURE,
HEIGHT BASED ON ROOM INDEX SHEET NO. 6C.1
CHRIST UNIVERSITY
(DEEMED TO BE UNIVERSITY)
HERE, WE HAVE BEEN
INTRODUCED BY A SOFTWARE
OF LADYBUG IN GRASSHOPPER
IN RHINO. WE ARE GIVEN TO
CALCULATE THE DRY BULB
TEMPERATURE, RELATIVE
AND NOTE THE VALUES OF SUN PATH FROM
HUMIDITY & WIND SPEED OF 7
6AM TO 5PM AND CALCULATE THE AVERAGE.
CONSECUTIVE DAYS OF A
AFTER WE HAVE COMPARED THE STIMULATED
MONTH ON LAST WORKED
SCRIPT VALUE WITH THE METEOROLOGICAL
SAME GIVEN LOCATION,
DATA ON INTERNET SOURCE (CREDITS :
VERAVAL, GUJRAT.
WWW.TIMEANDDATE.COM)

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 27.04.2022
SOLAR GEOMETRY: SUN PATH SEMESTER : 4

ANALYSIS FOR PERIOD FROM 24 SCALE :


SCHOOL OF ARCHITECTURE,
OCT 2021 TO 30 OCT 2021 CHRIST UNIVERSITY
SHEET NO. 7 (DEEMED TO BE UNIVERSITY)
BY HERE, WE STUDY ABOUT THE
CALCULATING OF THE SUN HOURS
FOR THE VERAVAL CITY WITH
IMPLEMENTING A CUB, BY
SHOWING THE DATA OF DRY BULB
TEMPERATURE

MAKING A VIEW OF TOP VIEW, FRONT


WE TRY TO CALCULATE THE DIRECT VIEW, SIDE VIEW, AND THE
SUN HOURS FOR 3 MONTHS / PERSPECTIVE VIEW OF THE CUBE
180 DAYS, SHOWING THE SUN PATH WITH SUN PATH ARCH
FROM 6AM TO 5PM

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 29.04.2022
MEASURING AVERAGE SOLAR SEMESTER : 4

EXPOSURE THE BUILDING SCALE :


SCHOOL OF ARCHITECTURE,
ENVELOPE RECEIVES CHRIST UNIVERSITY
SHEET NO. 8 (DEEMED TO BE UNIVERSITY)
HERE, WE STIMULATE THE
SCRIPT FOR INCIDENT
RADIANCE BY COLLECTING
DATA UNDER SKYMATRIX FOR
THE SUNPATH OF 3 MONTHS
PERIODS.

WE MADE THE MODEL OF OUR


WE ALSO TRIED TO BRING THE CURRENT DESIGN SITE WITH
CONTEXT OF BANGALORE BY EPW CONTEXT & VEGETATION WITH
FILE FROM EWP MAP CONNECTING ASSUMPTION OF OUR DESIGN
TO THE SCRIPT FORM AS A CUBOID AND FOUND
THE DATA FOR INCIDENT RADIANCE

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 05.05.2022 SEMESTER : 4
MEASURING INCIDENT SOLAR
RADIATION ON BUILDING ENVELOPE SCALE :
SCHOOL OF ARCHITECTURE,
CHRIST UNIVERSITY
SHEET NO. 9 (DEEMED TO BE UNIVERSITY)
COMING TO ONE OF THE
COMPLEX STIMULATION,
STIMULATING IN HONEYBEE
IN THE LADYBUG. HERE WE
TRIED TO MAKE THE SCRIPT
FOR THE CALCULATING
THE ANNUAL DAYLIGHT
UNDER HEATMAP
COMMAND FOR OUT OUR
DESIGN STUDIO
SCALED FORM WITH
WALLS, OPENINGS, AND
WINDOWS.

I TRIED TO BRING VARIOUS OPENING IN OUR THIS ONE UNDER THE IMAGE HAVE ADDED,
STRUCTURE TO NOTE THE DATA OF HOURS OF ONE IS THE ACCURATE ONE THAT I
PERSONALLY THINK COMPARING OUT OF
NATURAL LIGHT THAT FALL INTO THE STUDIO. OTHER DATA STIMULATION I WORKED ON.

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 09.05.2022 SEMESTER : 4

SOLAR GEOMETRY: SUN PATH ANALYSIS


SCALE :
SCHOOL OF ARCHITECTURE,
CHRIST UNIVERSITY
SHEET NO. 11 (DEEMED TO BE UNIVERSITY)
HEREBY, THIS SCRIPT OF ANNUAL DAYLIGHT UNDER HEATMAP PROPERTY GET THE STIMULATION FOR
OUR DESIGN STUDIO 3D MODEL.

NAME & ROLL NO. : RISHIGANESH S N 2061709


DATE : 09.05.2022 SEMESTER : 4

SOLAR GEOMETRY: SUN PATH ANALYSIS


SCALE :
SCHOOL OF ARCHITECTURE,
CHRIST UNIVERSITY
SHEET NO. 11 (DEEMED TO BE UNIVERSITY)