Emd Assignment (2) 2022

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

SAGI RAMA KRISHNAM RAJU ENGINEERING COLLEGE (A)

CHINNAAMIRAM: BHIMAVARAM-534204
DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

ASSIGNMENT-1

Academic Year: 2021-2022 Year/Semester: IV/IV - II Sections: A,B,C, & D


Name of the Course: Electrical Machine Design. Course Code: B17EE4201
Subject Teachers: VSV, SKN, NVAB & UBP Course Coordinator: VSV Max.Marks: 50

M CO KL
UNIT-III
1 Discuss in detail about different methods of cooling of transformers 5 CO3 K4

2 Estimate the dimensions of a 3phase delta/star core type transformer rated at 5 CO3 K4
200 kVA, 3000/400V, 50 Hz. A suitable core with three steps having a
circumscribing circle of 0.25 diameter and a leg spacing of 0.4 m is available.
the emf per turn is 7V; assuming a current density, 2.5 A/m2; window space
factor, 0.28 and a stacking factor of 0.9

UNIT-IV
3 What are the factors to be considered for selection of the number of slots in 5 CO4 K4
stator of induction machine?
4 Compare squirrel cage rotor and wound rotor induction motor. 5 CO4 K4

5 Determine the main dimensions of a 25 MVA, 50 Hz, 3-phase turbo alternator, 5 CO4 K4
given mean gap density=0.5 Tesla, specific electric loading of 550 ampere
conductors per cm. of armature periphery; peripheral speed should not exceed
145 m/s; Air gap is 3 cm.
6 A 3-phase induction motor has 56 stator slots with 8 conductors per slot and 7 5 CO4 K4
rotor slots with 5 conductors per slot. Find the number of stator and rotor turns.
Find the open circuited voltage across the slip rings at rest, both the stator and
rotor are star connected and a voltage of 440 V is applied across the stator
terminals.
UNIT-V
7 Derive the output equation of an AC Machine in terms of main dimensions. 5 CO5 K4

8 Describe the step-by-step procedure for design of field winding of synchronous 5 CO5 K4
machine
9 Determine the dimensions of a 1000 KVA, 2200V, 3 phase 8 pole, 50 Hz, star 5 CO5 K4
connected alternator. The winding has a 60 degrees phase spread and the coils
are full pitched. The specific magnetic and electric loadings may be taken as
0.62wb/m2 and 30000 ampere conductors/m. Use circular poles whose ratio of
pole arc to pole pitch is 0.65.
10 Give the developed view for the R-phase of a 3-phase, 4 pole, 24 slots, and star 5 CO5 K4
connected lap winding with coil short pitched by one slot. Each slot contains
two coil sides. Phase sequence is RYB

You might also like