Unique Selling Points LithoSpace 120210

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Unique selling points LithoSpace®

1. The LithoSpace® represents a new concept. A shock wave


source as a component for urology and orthopaedics.

2. The flexibility and manoeuvrability of the applicator allows


treatments of both “under and over” the table positions.

3. The revolutionary “SuperVision” an autonomous, “touchless”


targeting system for all X-Ray and ultrasound localisation
devices superimposes the therapeutic volume on the imported
medical image.

4. The LithoSpace® supports easy positioning either by the


highly flexible applicator or via the patient support.

5. The LithoSpace® enables optimal positioning under


supervision of the total therapeutic volume. Re-positioning
“on the fly” is easy and fast.

6. AST LithoSpace® generates a very effective Wide Focus


shock wave using a new electro caustic emitter (ECE) that
provides large therapeutic volume with fewer side effects.

7. Penetration depth of up to 220mm also makes it easy to


position obese patients.

8. Without expensive mechanical adaptation the LithoSpace®


is compatible with existing imaging modalities.

9. When not in use, LithoSpace® may be folded into the “park


position” and wheeled out of the operating theatre thereby
freeing up space.

120210 Unique selling points LithoSpace.doc Page 1 of 2 Stephan


AST GmbH, Moritz-Von-Rohr-Str. 1a, 07745 Jena, Germany, Tel +49 3641 50 49 0
Unique selling points LithoSpace® in details

Shock wave source


Treatment of urology indications Yes
Treatment of orthopaedic indications inclusive non unions on long bones Yes
electro caustic emitter
Principle of shock wave generation
(ECE)
Maximum penetration depth in mm 220
58° (160mm) /
Variable aperture angle depending on penetration depth
96° (80mm)
Archive function of all shock wave parameters Yes
Touchless adaptation of different c-arms Yes
Localization and positioning
Import of medical images Yes
Superposition of the therapeutic volume in the medical image in real time Yes
No need for an isocentric movement Yes
The standard X-Ray doses (e.g. 3,3 KW generator) are sufficient Yes
Principle of ultrasound positioning (In-line / outline mechanically guided / outline
outline free by hand
free by hand)
Positioning may be done by motor driven table positioning or motor driven
motor driven table
applicator movement.
Shock wave parameter according to EN 61846
Focal size at low energy level (Diameter x Length in mm) 10,8 x 121,9 (16KV)
Focal size at medium energy level (Diameter x Length in mm) 9,7 x 115,3 (22KV)
Focal size at high energy level (Diameter x Length in mm) 16,6 x 104 (26KV)
Maximum total focal energy in mJ 61,8
Minimum total focal energy in mJ 10,9
Movement range applicator
Height movement range in mm 400
Longitudinal movement range in mm 150
Lateral movement range in mm 430
Horizontal movement range in degree +/- 22°
Vertical movement range in degree +/- 57°

120210 Unique selling points LithoSpace.doc Page 2 of 2 Stephan


AST GmbH, Moritz-Von-Rohr-Str. 1a, 07745 Jena, Germany, Tel +49 3641 50 49 0