C-FIX 1.100.0.

0
Database version
2021.5.5.10.43
Date
13/10/2021

fischer FZE

Jebel Ali Free Zone Warehouse No XB


P.O. Box 261738 Dubai

Enquiry@fischer.ae
www.fischer.ae

Design Specifications
Anchor
Anchor system fischer Injection system FIS EM plus
Injection resin FIS EM Plus 390 S
Fixing element Threaded rod FIS A M 16 x 200 8.8,
zinc plated steel, Property Class 8.8
Calculated anchorage 160 mm
depth

Design Data Specification by manufacturer

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

Input data

Design method Design method ENSO Bonded


Base material C 30, BS EN 12390-3:2009
Concrete condition Non-cracked, dry hole
Temperature range 50 °C long term temperature, 72 °C short term temperature
Reinforcement Dense reinforcement. Edge reinforcement with stirrups
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap Annular gap filled
Type of loading Permanent-Transient/Static
Base plate location Base plate flush installed on base material
Base plate geometry 210 mm x 270 mm x 16 mm
Profile type Customized profile

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 22.58 -28.55 23.10 0.00 0.00 0.00 Permanent-Transient/Static
2 -23.64 18.29 22.84 0.00 0.00 0.00 Permanent-Transient/Static
3 9.13 -28.08 -29.51 0.00 0.00 0.00 Permanent-Transient/Static

*⁾ The required partial safety factors for actions are included

Resulting of the most decisive anchor forces.


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 5.65 9.18 -7.14 5.78
2 5.65 9.18 -7.14 5.78
3 5.65 9.18 -7.14 5.78
4 5.65 9.18 -7.14 5.78

max. concrete compressive strain : 0.00 ‰


max. concrete compressive stress : 0.0 N/mm²
Resulting tensile actions : 22.58 kN , X/Y position ( 0 / 0 )
Resulting compression actions : 0.00 kN , X/Y position ( 0 / 0 )

Resistance of the most decisive tensile loads.

Proof Action Capacity Utilisation βN


kN kN %
Steel failure * 5.65 84.00 6.7
Combined pull-out and concrete cone failure 22.58 52.06 43.4
Concrete cone failure 22.58 42.73 52.8
Splitting failure 22.58 94.46 23.9

* Most unfavourable anchor


The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

Steel failure

( NRd,s )

NRk,s γMs NRd,s NSd βN,s


kN kN kN %
126.00 1.50 84.00 5.65 6.7

βN,s
Anchor no. % Group N° Decisive Beta
1 6.7 1 βN,s;1
2 6.7 2 βN,s;2
3 6.7 3 βN,s;3
4 6.7 4 βN,s;4

Combined pull-out and concrete cone failure

( NRd,p )

Eq. (5.2)

Eq. (5.2a)

Eq. (7.14a)

Eq. (7.15)

Eq. (7.16)

Eq. (5.2e)

Eq. (5.2f)

Eq. (5.2g)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

Eq. (5.2h)

Eq. (5.2i)

NRk,p γMp NRd,p NSd βN,p


kN kN kN %
78.09 1.50 52.06 22.58 43.4

βN,p
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 43.4 1 βN,p;1

Concrete cone failure

( NRd,c )

Eq. (5.3)

Eq. (5.3a)

Eq. (5.3c)

Eq. (5.3d)

Eq. (5.3e)

NRk,c γMc NRd,c NSd βN,c


kN kN kN %
64.10 1.50 42.73 22.58 52.8

βN,c
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 52.8 1 βN,c;1

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

Splitting failure due to loading

( NRd,sp )

Eq. (5.4)

Eq. (5.3a)

Eq. (5.3c)

Eq. (5.3d)

Eq. (5.3e)

Eq. fib (10.1-5a)

NRk,sp γMsp NRd,sp NSd βN,sp


kN kN kN %
141.69 1.50 94.46 22.58 23.9

βN,sp
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 23.9 1 βN,sp;1

Resistance of the most decisive shear loads.

Proof Action Capacity Utilisation βV


kN kN %
Steel failure without lever arm * 9.18 50.40 18.2
Concrete pry-out failure 36.72 85.46 43.0
Concrete edge failure 18.36 25.87 71.0

* Most unfavourable anchor

Steel failure without lever arm

( VRd,s )

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

VRk,s γMs VRd,s VSd βVs


kN kN kN %
63.00 1.25 50.40 9.18 18.2

βVs
Anchor no. % Group N° Decisive Beta
1 18.2 1 βVs;1
2 18.2 2 βVs;2
3 18.2 3 βVs;3
4 18.2 4 βVs;4

Concrete pry-out failure

( VRd,cp )

Eq. (5.7a)

Eq. (5.3)

Eq. (5.3a)

Eq. (5.3c)

Eq. (5.3d)

Eq. (5.3e)

VRk,cp γMcp VRd,cp VSd βV,cp


kN kN kN %
128.20 1.50 85.46 36.72 43.0

βV,cp
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 43.0 1 βV,cp;1

Concrete edge failure

( VRd,c )

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

Eq. (5.8)

Eq. (5.8a)

Eq. (5.8b/c)

Eq. (5.8e)

Eq. (5.8f)

Eq. (10.2-5f)

Eq. (5.8h)

VRk,c γMc VRd,c VSd βV,c


kN kN kN %
38.80 1.50 25.87 18.36 71.0

βV,c
Anchor no. % Group N° Decisive Beta
1, 3 71.0 1 βV,c;1
2, 4 60.6 2 βV,c;2

Most decisive result from tension and shear loads.

Tension loads Utilisation βN Shear Loads Utilisation βV


% %
Steel failure * 6.7 Steel failure without lever arm * 18.2
Combined pull-out and concrete cone failure 43.4 Concrete pry-out failure 43.0
Concrete cone failure 52.8 Concrete edge failure 71.0
Splitting failure 23.9
* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

Resistance of the most decisive combined loads.


Utilisation steel
Eq. (5.9a)

Eq. (5.9b)

Eq. (5.10)

Utilisation concrete Proof successful


Eq. (5.9a)

Eq. (5.9b)

Eq. (5.10)

Non decisive load cases.


# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading βN βV β
kN kN kN kNm kNm kNm % % %
2 -23.64 18.29 22.84 0.00 0.00 0.00 Permanent-Transient/Static 0.00 49.70 0.00
3 9.13 -28.08 -29.51 0.00 0.00 0.00 Permanent-Transient/Static 21.37 73.12 72.40

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 16 mm

Profile type Customized profile

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate (if present) must
be sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about the
stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

Technical remarks for the calculation of multiple load cases


The calcualtion was done based on the input of several load cases. The software is determining the decisive load case for
the fixing itself. This can be varify to the general decisive load case in the structure. Every result has to be checked by the
design engineer and varified with the calculation of the structure.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 8
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

Installation data
Anchor
Anchor system fischer Injection system FIS EM
plus
Injection resin FIS EM Plus 390 S (other cartridge Art.-No. 544154
sizes available)
Fixing element Threaded rod FIS A M 16 x 200 8.8, Art.-No. 517939
zinc plated steel, Property Class 8.8

Accessories FIS MR Plus Art.-No. 545853


FIS Extension tube 9mm Art.-No. 48983
Dispenser FIS DM S Art.-No. 511118
Compressed-air cleaning tool Art.-No. 93286
compressed air (oil-free), min. 6 bar By job site.
BSD 18 Art.-No. 1493
SDS Chuck with internal thread M8 Art.-No. 530332
Quattric II 18/200/250 Art.-No. 549956
or alternatively
FHD 18/320/450 Art.-No. 546600
Hammer drilling with or without
suction
Alternative cartdriges FIS EM Plus 585 S Art.-No. 544166
FIS EM Plus 1500 S Art.-No. 544173
The shown cartdriges are
alternative to the highlighted
one above with the same approval
number.

Installation details
Thread diameter M 16
Drill hole diameter d0 = 18 mm
Drill hole depth h2 = 176 mm
Calculated anchorage hef = 160 mm
depth
Drilling method Hammer drilling
Drill hole cleaning 2 times blowing (compressed air),
2 times brushing,
2 times blowing (compressed air)
No borehole cleaning required in
case of using a hollow drill bit, e.g.
fischer FHD.
Installation type Push-through installation
Annular gap Annular gap filled
Maximum torque Tinst,max = 60.0 Nm
Socket size 24 mm
Base plate thickness t = 16 mm
Total fixing thickness tfix = 16 mm
Tfix,max
Volume of resin per drill 22 ml/11 scale divisions
hole

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 9
C-FIX 1.100.0.0
Database version
2021.5.5.10.43
Date
13/10/2021

Base plate details


Base plate material S 275
Base plate thickness t = 16 mm
Clearance hole in base df=20 mm
plate

Attachment
Profile type Customized profile

Profile dimensions mm
Height 16

Anchor coordinates

x y
Anchor no. mm mm
1 -55 95
2 55 95
3 -55 -95
4 55 -95

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 10