DESCRIPTION

DESCRIPTION

DESCRIPTION
FIN. FL. ELEV. (+8.00' NGVD)

s i f ie
l as

d
R
Sy
s t em

CAJ-1304
1 or 2 Hour Fire Rated Through 1 or 2 Hour Fire Rated Through
ss i f ie Penetration Firestop for Multiple ss i f ie Penetration Firestop for Single
la la

C
d

d
Metal Pipe through 3735 Green Rd.
Metallic Pipe through 3735 Green Rd.
R Concrete Floors or Walls Beachwood, OH, 44122 R Gypsum Walls using Beachwood, OH, 44122
Sy using FYRE-SHIELD. Sy TREMstop IA.
s t em s t em
Drawing not to scale Drawing not to scale
CAJ 1047 F-Rating = 1 and 2 Hr.
T-Rating = 0 Hr.
WL 1113 F-Rating = 1 and 2 Hr.
T-Rating = 0 Hr.
2
4 1
2 4

3
2

1 2
1 Pre-Rated Concrete Floors or Block Walls = Min. 4-1/2" thickness 3
Max. Area of Opening = 288 sq. in., with a Max. Dimension of 24".
2 Metallic Pipe: A) Steel Pipe - 8" diam. (or smaller) Sch. 40 (or heavier) steel pipe. 1 Pre-Rated Gypsum Wallboard/Stud Wall Assembly
B) Conduit - 4" diam. (or smaller) EMT or 6" diam. (or smaller) steel conduit.
2 Metallic Pipe - A) Steel Pipe - 4" diam. (or smaller) Sch. 40 (or heavier) steel pipe.
C) Iron Pipe - 8" diam. (or smaller) cast or ductile iron pipe.
D) Copper Tubing - 4" diam. (or smaller) Type L (or heavier) copper tubing. B) Iron Pipe - 4" diam. (or smaller) cast or ductile iron pipe.

E) Copper Pipe - 4" diam. (or smaller) Regular (or heavier) copper pipe. C) Conduit - 4" diam. (or smaller) EMT or rigid steel conduit.
NOTE: The maximum number of pipes within opening is 3. The annular space between D) Copper Tubing - 4" diam. (or smaller) Type L (or heavier) copper tubing.
pipes shall be min. 1-1/2" and a min. 1/2" between pipes and edge of opening. E) Copper Pipe - 4" diam. (or smaller) Regular (or heavier) copper pipe.
3 Forming Material - (Not Shown, Optional) Nom. 1" thick polyurethane backer rod The annular space shall be min. 1/4" to max. 5/8" within the firestop system.
firmly packed into the opening as a permanent form. 3 TREMstop IA - Min. 1/2" thickness of sealant applied within opening. Additional sealant
4 FYRE-SHIELD - Min. 1/2" thickness mastic applied within annulus, flush with top surface to be installed such that a min. 1/4" crown is formed around the
of floor or with both surfaces of the wall assembly. penetrating item.
W
W MH: 18
MH: 18

W1
FIN. FL. ELEV. (+8.00' NGVD) MH: 9.5

W1 W1
MH: 9.5 MH: 9.5
25.8 27.3 26.1

1.0 1.3 1.7 1.9 2.0 1.8 1.5 1.2 1.0 28.0 28.9 27.4

24.3 24.7 32.7 29.9 BE


1.2 1.5 1.8 2.1 2.3 2.3 2.2 1.9 1.6 1.3 22.0 21.5 35.5 32.1
19.9 19.6 38.1 34.3
17.7 17.8 40.6 36.3
1.2 15.6 16.1 42.8 38.3
13.9 14.5 44.3 39.6
2.0 2.5 2.9 3.3 3.3 2.9 2.6 2.1 1.7
12.5 13.1 44.8 39.3 B
1.7 11.0 11.9 43.5 38.3
34.1 37.2 34.2

2.5 3.1 3.5 3.9 3.8 3.6 3.2 2.5 1.9 1.6 1.1 A A A A
8.2 11.9 12.4 9.6 9.0 8.5 10.4 17.5 21.1 20.2 15.2 8.8

1.9

2.4 3.0 3.6 4.1 4.0 3.7 3.0 2.8 2.3 1.9 1.1

2.0
2.6 3.1 3.6 3.7 3.5 3.0 2.5 3.2 2.4 1.8 1.0

W 1.4 2.0
W MH: 18 2.2 2.4 2.3
1.4 2.3
0.0 MH: 18 2.3 1.1
1.5 2.4 2.4 2.5 2.4
2.0 2.0 2.8 2.5 BE
1.6 2.2 0.4
1.8 1.7 2.9 2.6
1.5 2.3 2.6 1.4 1.6 1.5 3.0 2.7
0.0 1.4 1.4 3.0 2.6
W1 1.2 2.3
1.2 1.2 2.9 2.6
FIN. FL. ELEV. (+8.00' NGVD) MH: 9.5 1.1 1.1 2.7 2.4
1.5 2.4
0.5 1.1 1.1 2.5 2.2
1.6 2.2 1.0 1.2 2.3 1.9

1.7 1.8 1.7


0.0 1.5 2.4

A A A A
W1 W1 1.4 2.3
1.1 1.6 1.7 1.4 1.2 1.1 0.9 1.4 1.6 1.5 1.3 0.8
MH: 9.5 MH: 9.5 1.1 1.8
0.3

2.1 2.3 2.2 2.1 2.4 2.7 2.4 2.1 2.2 2.3 2.9 3.3
0.9
3.8 3.7

3.7 3.7 0.4


3.1 3.2

1.0 2.2 2.2

1.0 1.3 1.7 1.9 1.6 1.2 1.1 0.4


Luminaire Schedule

Symbol Qty Label Arrangement Manufacturer Description Lum. Lumens LLF Lum. Watts Voltage Mounting Remarks

4 A SINGLE Brownlee Lighting 7601-C9LED-40K-EM 555 0.860 8.4 120V Wall w/ battery back-up
(at 6' high)

1 B SINGLE Kenall Manufacturing MOS-18-MW-TA-50L40K-DV 4833 0.860 56.3 120V Ceiling


(Surface)

1 BE SINGLE Kenall Manufacturing MOS-18-MW-TA-50L40K-DV-LEL 4833 0.860 56.3 120V Ceiling w/ battery back-up
(Surface)

2 W SINGLE US Architectural RZR-WM2-PLED-IV-FT-40LED-1050mA 8341 0.860 133.4 120V Wall


Lighting NW-HS-PLED (at 18' high)

W1 SINGLE US Architectural RZR-WM1-PLED-III-M-20LED-350mA Wall


3 1823 0.860 22.3 120V
Lighting NW-HS-PLED (at 9.5' high)

Calculation Summary

Label CalcType Units Avg Max Min Avg/Min Max/Min

Approach Illuminance Fc 1.42 1.9 1.0 1.42 1.90

Parking Illuminance Fc 2.70 4.1 1.1 2.45 3.73

Walkway Illuminance Fc 2.34 3.8 1.1 2.13 3.45

Stairs Illuminance Fc 28.18 44.8 11.0 2.56 4.07

Porch - Ground Floor Illuminance Fc 9.93 12.4 8.2 1.21 1.51

Porch - Second Floor Illuminance Fc 15.53 21.1 8.8 1.76 2.40

Stairs (Emergency) Illuminance Fc 2.03 3.0 1.0 2.03 3.00

Porch - Ground Floor (Emergency) Illuminance Fc 1.35 1.7 1.1 1.23 1.55

Porch - Second Floor (Emergency) Illuminance Fc 1.25 1.6 0.8 1.56 2.00
REScheck Software Version 4.6.5

Compliance Certificate

Project 4 Unit Building Gilberto Aguila


Energy Code: 2017 Florida Building Code, Energy Conservation
Location: Miami, Florida
Construction Type: Multi-family
Project Type: New Construction
Conditioned Floor Area: 2,538 ft2
Glazing Area 9%
Climate Zone: 1 (139 HDD)
Permit Date:
Permit Number:

Construction Site: Owner/Agent: Designer/Contractor:


545 E 24th. Street Proposed 4 Unit Building
Hialeah, FL Gilberto Aguila
5735 W 12 Lane
Hialeah, FL

Compliance: Envelope passes UA trade-off. Additional mandatory requirements apply. Complete the REScheck inspection
Compliance: 26.7% Better Than Code Maximum UA: 1028 Your UA: 754 Maximum SHGC: 0.25 Your SHGC: 0.25
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.

Envelope Assemblies
Gross Area
Cavity Cont.
Assembly or U-Factor UA
R-Value R-Value
Perimeter

Wall 5: Wood Frame, 16" o.c. 279 5.0 0.0 0.121 34

Wall 6: Wood Frame, 16" o.c. 279 5.0 0.0 0.121 34

Wall 1: Masonry Block with Integral Insulation 855 17.8 0.0 0.058 43
Window 1: Metal Frame:Single Pane 108 1.070 116
SHGC: 0.25
Wall 2: Masonry Block with Integral Insulation 536 17.8 0.0 0.058 28
Window 1: Metal Frame:Single Pane 48 1.070 51
SHGC: 0.25
Wall 3: Masonry Block with Integral Insulation 720 17.8 0.0 0.058 31

Door 1: Solid 84 0.390 33


Window 1: Metal Frame:Single Pane 96 1.070 103
SHGC: 0.25
Wall 4: Masonry Block with Integral Insulation 536 17.8 0.0 0.058 29
Window 1: Metal Frame:Single Pane 32 1.070 34
SHGC: 0.25
Floor 1: Slab-On-Grade:Unheated 147 0.0 1.042 153
Insulation depth: 0.5'
Ceiling 1: Flat Ceiling or Scissor Truss 1,269 19.0 0.0 0.051 65

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 1 of10
Mechanical Equipment
Description Fuel type Efficiency

Electric Central Air 16 SEER


Electric Central Air 16 SEER
Electric Central Air 16 SEER
Electric Central Air 16 SEER

Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2017 Florida Building Code,
Energy Conservation requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck
Inspection Checklist.

Name - Title Signature Date

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 2 of10
REScheck Software Version 4.6.5
Inspection Checklist
Energy Code: 2017 Florida Building Code, Energy Conservation
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.

Section
Plans Verified Field Verified
# Pre-Inspection/Plan Review Complies? Comments/Assumptions
Value Value
& Req.ID
103.1, Construction drawings and Complies Requirement will be met.
103.2 documentation demonstrate Does Not
[PR1]1 energy code compliance for the
Not Observable
building envelope. Thermal
envelope represented on Not Applicable
construction documents.
103.1, Construction drawings and Complies Requirement will be met.
103.2, documentation demonstrate Does Not
403.7, energy code compliance for
Not Observable
403.8 lighting and mechanical systems.
[PR3]1 Systems serving multiple Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr_____ Btu/hr_____ Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: Not Observable
Manual J or other methods Btu/hr_____ Btu/hr_____
approved by the code official. Not Applicable

302.1, Heating and cooling equipment is Heating: Heating: Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr_____ Btu/hr_____ Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: Not Observable
Manual J or other methods Btu/hr_____ Btu/hr_____
approved by the code official. Not Applicable
Refer to R403.7.1 for full details.

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 3 of10
Section
Plans Verified Field Verified
# Foundation Inspection Complies? Comments/Assumptions
Value Value
& Req.ID
303.2.1.3 A protective covering is installed Complies Exception: Requirement is
[FO11]2 to protect exposed exterior Does Not not applicable.
insulation and extends a
Not Observable
minimum of 6 in. below grade.
Not Applicable
402.1.2 Slab edge insulation R-value. R-_____ R-_____ Complies See the Envelope Assemblies
[FO1]1 table for values.
Unheated Unheated Does Not
Heated Heated Not Observable
Not Applicable

402.1.2 Slab edge insulation _____ ft _____ ft Complies See the Envelope Assemblies
[FO3]1 depth/length. table for values.
Does Not
Not Observable
Not Applicable
403.9 Snow- and ice-melting system Complies Exception: Requirement is
[FO12]2 controls installed. Does Not not applicable.
Not Observable
Not Applicable

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 4 of10
Section
Plans Verified Field Verified
# Framing / Rough-In Inspection Complies? Comments/Assumptions
Value Value
& Req.ID
303.1.3 U-factors of fenestration products Complies Requirement will be met.
[FR4]1 are determined in accordance Does Not
with the NFRC test procedure or
Not Observable
taken from the default table.
Not Applicable
402.1.1, Glazing U-factor (area-weighted U-_____ U-_____ Complies See the Envelope Assemblies
402.3.1, average). table for values.
Does Not
402.3.3,
Not Observable
503.1.1.1
[FR2]1 Not Applicable

402.1.1, Glazing SHGC value (area- SHGC:_____ SHGC:_____ Complies See the Envelope Assemblies
402.3.2, weighted average). table for values.
Does Not
402.3.3
Not Observable
[FR3]1
Not Applicable

402.1.1, Door U-factor. U-_____ U-_____ Complies See the Envelope Assemblies
402.3.4 table for values.
Does Not
[FR1]1
Not Observable
Not Applicable
402.4.1.1 Air barrier and thermal barrier Complies Requirement will be met.
[FR23]1 installed per manufacturer’s Does Not
instructions.
Not Observable
Not Applicable
402.4.3 Fenestration that is not site built Complies Requirement will be met.
[FR20]1 is listed and labeled as meeting Does Not
AAMA /WDMA/CSA 101/I.S.2/A440
Not Observable
or has infiltration rates per NFRC
400 that do not exceed code Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures Complies Requirement will be met.
[FR16]2 sealed at housing/interior finish Does Not
and labeled to indicate ≤2.0 cfm
Not Observable
leakage at 75 Pa.
Not Applicable
403.3.1 Supply and return ducts in attics Complies Requirement will be met.
[FR12]1 insulated >= R-8 where duct is Does Not
>= 3 inches in diameter and >=
Not Observable
R-6 where < 3 inches. Supply and
return ducts in other portions of Not Applicable
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
403.3.5 Building cavities are not used as Complies Requirement will be met.
[FR15]3 ducts or plenums. Does Not
Not Observable
Not Applicable
403.4 HVAC piping conveying fluids R-_____ R-_____ Complies Exception: Requirement is
[FR17]2 above 105 ºF or chilled fluids Does Not not applicable.
below 55 ºF are insulated to ≥R-
Not Observable
3.
Not Applicable
403.4.1 Protection of insulation on HVAC Complies Exception: Requirement is
[FR24]1 piping. Does Not not applicable.
Not Observable
Not Applicable
403.5.3 Hot water pipes are insulated to R-_____ R-_____ Complies Exception: Requirement is
[FR18]2 ≥R-3. Does Not not applicable.
Not Observable
Not Applicable

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 5 of10
Section
Plans Verified Field Verified
# Framing / Rough-In Inspection Complies? Comments/Assumptions
Value Value
& Req.ID
403.5.5 Storage water heaters not Complies Exception: Requirement is
[FR26]2 equipped with integral heat traps Does Not not applicable.
and having vertical pipe risers
Not Observable
have heat traps installed on both
the inlets and outlets. External Not Applicable
heat traps installed per code
guildlines.
403.5.6.1. Service water heating systems Complies Exception: Requirement is
1 are equipped with automatic Does Not not applicable.
[FR27]2 temperature controls.
Not Observable
Not Applicable
403.5.6.1. A separate switch permits the Complies Exception: Requirement is
2 power supplied to electric service Does Not not applicable.
[FR28]2 water systems to be turned off. A
Not Observable
separate valve permits the
energy supplied to the main Not Applicable
burner(s) of combustion types of
service water heating systems to
be turned off.
403.5.6.2 Water heating equipment meets Table 404.2 Table 404.2 Complies Exception: Requirement is
[FR29]2 minimum efficiencies of Table (required (required Does Not not applicable.
C404.2 in Chapter 4 of the Ef):_____ Ef):_____
Not Observable
Florida Building Code, Energy
Conservation, Commercial Not Applicable
Provisions. Equipment used to
provide heating functions as part
of a combination system satisfies
all stated requirements for the
appropriate water heating
category.
403.5.6.2. Solar systems for domestic hot Complies Exception: Requirement is
1 water production satisfy energy Does Not not applicable.
[FR30]2 factor requirements determined
Not Observable
from the Florida Solar Energy
Center Directory of Certified Not Applicable
Solar Systems.
403.6 Automatic or gravity dampers are Complies Requirement will be met.
[FR19]2 installed on all outdoor air Does Not
intakes and exhausts.
Not Observable
Not Applicable
403.6.2 Buildings designed to operate at Complies Exception: Requirement is
[FR31]2 positive indoor pressure or have Does Not not applicable.
mechanical ventilation meet the
Not Observable
following criteria: 1) Maximum
air-change-hour equal minimums Not Applicable
from ASHRAE 62, Ventilation for
Acceptable Indoor Air Quality, 2)
No ventilation or air-conditioning
system make-up air provided
from attics, crawlspaces,
attached enclosed garages or
outdoor spaces adjacent to
swimming pools or spas, and 3)
Air drawn from enclosed space(s)
have walls insulated >= R-11
and ceiling >= R-19, space
permitting, or R-10 otherwise.

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 6 of10
Section
Plans Verified Field Verified
# Insulation Inspection Complies? Comments/Assumptions
Value Value
& Req.ID
303.1 All installed insulation is labeled Complies Requirement will be met.
[IN13]2 or the installed R-values Does Not
provided.
Not Observable
Not Applicable
303.2 Wall insulation is installed per Complies Requirement will be met.
[IN4]1 manufacturer’s instructions. Does Not
Not Observable
Not Applicable
402.1.1, Wall insulation R-value. If this is a R-_____ R-_____ Complies See the Envelope Assemblies
402.2.5, mass wall with at least ½ of the table for values.
Wood Wood Does Not
402.2.6 wall insulation on the wall Mass Mass Not Observable
[IN3]1 exterior, the exterior insulation
Steel Steel Not Applicable
requirement applies (FR10).

402.2.14 Walls, ceilings or floors common Complies Exception: Requirement is


[IN14]2 to separate conditioned Does Not not applicable.
tenancies are insulated to >= R-
Not Observable
11, space permitting. Mass
common walls are insulated to Not Applicable
>= R-6.

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 7 of10
Section
Plans Verified Field Verified
# Final Inspection Provisions Complies? Comments/Assumptions
Value Value
& Req.ID
303.1.1.2. Ceiling insulation installed per Complies Requirement will be met.
1, 303.2 manufacturer’s instructions. Does Not
[FI2]1 Blown insulation marked every
Not Observable
300 ft².
Not Applicable
303.3 Manufacturer manuals for Complies Requirement will be met.
[FI18]3 mechanical and water heating Does Not
systems have been provided.
Not Observable
Not Applicable
401.3 An energy performance level Complies Requirement will be met.
[FI33]2 (EPL) display card must be Does Not
completed and certified by the
Not Observable
builder before final approval of
the building for occupancy. Not Applicable
Florida law (Section 553.9085,
Florida Statutes) requires the EPL
display card to be included as an
addendum to each sales contract
for both presold and nonpresold
residential buildings. A copy of
the EPL card form can be found
in Appendix C of the "FBC,
Energy Conservation".
402.1.1, Ceiling insulation R-value. R-_____ R-_____ Complies See the Envelope Assemblies
402.2.1, table for values.
Wood Wood Does Not
402.2.2, Steel Steel Not Observable
402.2.6
[FI1]1 Not Applicable

402.2.3 Vented attics with air permeable Complies Exception: Requirement is


[FI22]2 insulation include baffle adjacent Does Not not applicable.
to soffit and eave vents that
Not Observable
extends over insulation.
Not Applicable
402.2.4 Attic access hatch and door R-_____ R-_____ Complies Requirement will be met.
[FI3]1 insulation ≥R-value of the Does Not
adjacent assembly.
Not Observable
Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=7 ACH 50 =_____ ACH 50 =_____ Complies Requirement will be met.
[FI17]1 ach. Does Not
Not Observable
Not Applicable
403.1.1 Each separate heating/cooling Complies Requirement will be met.
[FI9]2 system has a thermostat Does Not
Not Observable
Not Applicable
403.1.2 Programmable thermostats Complies Requirement will be met.
[FI9]2 installed for control of primary Does Not
heating and cooling systems and
Not Observable
initially set by manufacturer to
code specifications. Not Applicable
403.1.3 Heat pump thermostat installed Complies Exception: Requirement is
[FI10]2 on heat pumps. Does Not not applicable.
Not Observable
Not Applicable
403.2 Hot water boilers supplying heat Complies Exception: Requirement is
[FI26]2 through one- or two-pipe heating Does Not not applicable.
systems have outdoor setback
Not Observable
control to lower boiler water
temperature based on outdoor Not Applicable
temperature.

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 8 of10
Section
Plans Verified Field Verified
# Final Inspection Provisions Complies? Comments/Assumptions
Value Value
& Req.ID
403.3.2, All ducts, air handlers, and filter Complies Requirement will be met.
403.3.2.1 boxes shall be constructed and Does Not
[FI24]1 sealed in accordance with
Not Observable
Section C403.2.9.2 of the
Commercial Provisions of this Not Applicable
code. Air handler leakage
designated by manufacturer at
<=2% of design air flow.
403.3.3 Ducts are pressure tested to _____ cfm/100 _____ cfm/100 Complies Exception: Requirement is
[FI27]1 determine air leakage with ft2 ft2 Does Not not applicable.
either: Rough-in test: Total
Not Observable
leakage measured with a
pressure differential of 0.1 inch Not Applicable
w.g. across the system including
the manufacturer’s air handler
enclosure if installed at time of
test. Postconstruction test: Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer’s air
handler enclosure.
403.3.4, Duct tightness test result of <=4 _____ cfm/100 _____ cfm/100 Complies Exception: Requirement is
403.3.2 cfm/100 ft2 across the system or ft2 ft2 Does Not not applicable.
[FI4]1 <=3 cfm/100 ft2 without air
Not Observable
handler @ 25 Pa. For rough-in
tests, verification may need to Not Applicable
occur during Framing Inspection.
Duct tightness verified by testing
in accordance with
ANSI/RESNET/ICC 380-2016 by
either individuals as defined in
Section 553.993(5) or (7), Florida
Statutes, or individuals licensed
as set forth in Section
489.105(3)(f), (g), or (i), Florida
Statutes, to be “substantially leak
free” in accordance with Section
R403.3.3.
403.3.6 Air handling units are not Complies Requirement will be met.
[FI33]2 installed in attic. Does Not
Not Observable
Not Applicable
403.5.1 Circulating service hot water Complies Exception: Requirement is
[FI11]2 systems have automatic or Does Not not applicable.
accessible manual controls.
Not Observable
Not Applicable
403.5.1.1 Heated water circulation systems Complies Exception: Requirement is
[FI28]2 have a circulation pump. The Does Not not applicable.
system return pipe is a dedicated
Not Observable
return pipe or a cold water supply
pipe. Gravity and thermos- Not Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 9 of10
Section
Plans Verified Field Verified
# Final Inspection Provisions Complies? Comments/Assumptions
Value Value
& Req.ID
403.5.1.2 Electric heat trace systems Complies Exception: Requirement is
[FI29]2 comply with IEEE 515.1 or UL Does Not not applicable.
515. Controls automatically
Not Observable
adjust the energy input to the
heat tracing to maintain the Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that Complies Exception: Requirement is
[FI30]2 have recirculation pumps that Does Not not applicable.
pump water from a heated water
Not Observable
supply pipe back to the heated
water source through a cold Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 104ºF.
403.5.4 Drain water heat recovery units Complies Exception: Requirement is
[FI31]2 tested in accordance with CSA Does Not not applicable.
B55.1. Potable water-side
Not Observable
pressure loss of drain water heat
recovery units < 3 psi for Not Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
403.6.1 All mechanical ventilation system Complies Exception: Requirement is
[FI25]2 fans not part of tested and listed Does Not not applicable.
HVAC equipment meet efficacy
Not Observable
and air flow limits.
Not Applicable
404.1 75% of lamps in permanent Complies Requirement will be met.
[FI6]1 fixtures or 75% of permanent Does Not
fixtures have high efficacy lamps.
Not Observable
Does not apply to low-voltage
lighting. Not Applicable
404.1.1 Fuel gas lighting systems have Complies Exception: Requirement is
[FI23]3 no continuous pilot light. Does Not not applicable.
Not Observable
Not Applicable

Additional Comments/Assumptions:

1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)

Project Title: 4 Unit Building Gilberto Aguila Report date: 04/28/18


Data filename: C:\Users\Managaer\AppData\Local\Check\REScheck\4 Unit Building Gilberto Aguila.rck Page 10 of10
System No. C-AJ-1226
F RATING = 3-HR.
T RATING = 0-HR.
L Rating At Ambient - Less than 1 CFM/Sq Ft
L Rating At 400 F - 4 CFM/Sq Ft

SECTION A-A
RETURN