DESCRIPTION
DESCRIPTION
FIN. FL. ELEV. (+8.00' NGVD)
s i f ie
l as
d
R
Sy
s t em
CAJ-1304
1 or 2 Hour Fire Rated Through 1 or 2 Hour Fire Rated Through
ss i f ie Penetration Firestop for Multiple ss i f ie Penetration Firestop for Single
la la
C
d
d
Metal Pipe through 3735 Green Rd.
Metallic Pipe through 3735 Green Rd.
R Concrete Floors or Walls Beachwood, OH, 44122 R Gypsum Walls using Beachwood, OH, 44122
Sy using FYRE-SHIELD. Sy TREMstop IA.
s t em s t em
Drawing not to scale Drawing not to scale
CAJ 1047 F-Rating = 1 and 2 Hr.
T-Rating = 0 Hr.
WL 1113 F-Rating = 1 and 2 Hr.
T-Rating = 0 Hr.
2
4 1
2 4
3
2
1 2
1 Pre-Rated Concrete Floors or Block Walls = Min. 4-1/2" thickness 3
Max. Area of Opening = 288 sq. in., with a Max. Dimension of 24".
2 Metallic Pipe: A) Steel Pipe - 8" diam. (or smaller) Sch. 40 (or heavier) steel pipe. 1 Pre-Rated Gypsum Wallboard/Stud Wall Assembly
B) Conduit - 4" diam. (or smaller) EMT or 6" diam. (or smaller) steel conduit.
2 Metallic Pipe - A) Steel Pipe - 4" diam. (or smaller) Sch. 40 (or heavier) steel pipe.
C) Iron Pipe - 8" diam. (or smaller) cast or ductile iron pipe.
D) Copper Tubing - 4" diam. (or smaller) Type L (or heavier) copper tubing. B) Iron Pipe - 4" diam. (or smaller) cast or ductile iron pipe.
E) Copper Pipe - 4" diam. (or smaller) Regular (or heavier) copper pipe. C) Conduit - 4" diam. (or smaller) EMT or rigid steel conduit.
NOTE: The maximum number of pipes within opening is 3. The annular space between D) Copper Tubing - 4" diam. (or smaller) Type L (or heavier) copper tubing.
pipes shall be min. 1-1/2" and a min. 1/2" between pipes and edge of opening. E) Copper Pipe - 4" diam. (or smaller) Regular (or heavier) copper pipe.
3 Forming Material - (Not Shown, Optional) Nom. 1" thick polyurethane backer rod The annular space shall be min. 1/4" to max. 5/8" within the firestop system.
firmly packed into the opening as a permanent form. 3 TREMstop IA - Min. 1/2" thickness of sealant applied within opening. Additional sealant
4 FYRE-SHIELD - Min. 1/2" thickness mastic applied within annulus, flush with top surface to be installed such that a min. 1/4" crown is formed around the
of floor or with both surfaces of the wall assembly. penetrating item.
W
W MH: 18
MH: 18
W1
FIN. FL. ELEV. (+8.00' NGVD) MH: 9.5
W1 W1
MH: 9.5 MH: 9.5
25.8 27.3 26.1
1.0 1.3 1.7 1.9 2.0 1.8 1.5 1.2 1.0 28.0 28.9 27.4
2.5 3.1 3.5 3.9 3.8 3.6 3.2 2.5 1.9 1.6 1.1 A A A A
8.2 11.9 12.4 9.6 9.0 8.5 10.4 17.5 21.1 20.2 15.2 8.8
1.9
2.4 3.0 3.6 4.1 4.0 3.7 3.0 2.8 2.3 1.9 1.1
2.0
2.6 3.1 3.6 3.7 3.5 3.0 2.5 3.2 2.4 1.8 1.0
W 1.4 2.0
W MH: 18 2.2 2.4 2.3
1.4 2.3
0.0 MH: 18 2.3 1.1
1.5 2.4 2.4 2.5 2.4
2.0 2.0 2.8 2.5 BE
1.6 2.2 0.4
1.8 1.7 2.9 2.6
1.5 2.3 2.6 1.4 1.6 1.5 3.0 2.7
0.0 1.4 1.4 3.0 2.6
W1 1.2 2.3
1.2 1.2 2.9 2.6
FIN. FL. ELEV. (+8.00' NGVD) MH: 9.5 1.1 1.1 2.7 2.4
1.5 2.4
0.5 1.1 1.1 2.5 2.2
1.6 2.2 1.0 1.2 2.3 1.9
A A A A
W1 W1 1.4 2.3
1.1 1.6 1.7 1.4 1.2 1.1 0.9 1.4 1.6 1.5 1.3 0.8
MH: 9.5 MH: 9.5 1.1 1.8
0.3
2.1 2.3 2.2 2.1 2.4 2.7 2.4 2.1 2.2 2.3 2.9 3.3
0.9
3.8 3.7
Symbol Qty Label Arrangement Manufacturer Description Lum. Lumens LLF Lum. Watts Voltage Mounting Remarks
4 A SINGLE Brownlee Lighting 7601-C9LED-40K-EM 555 0.860 8.4 120V Wall w/ battery back-up
(at 6' high)
1 BE SINGLE Kenall Manufacturing MOS-18-MW-TA-50L40K-DV-LEL 4833 0.860 56.3 120V Ceiling w/ battery back-up
(Surface)
Calculation Summary
Porch - Ground Floor (Emergency) Illuminance Fc 1.35 1.7 1.1 1.23 1.55
Porch - Second Floor (Emergency) Illuminance Fc 1.25 1.6 0.8 1.56 2.00
REScheck Software Version 4.6.5
Compliance Certificate
Compliance: Envelope passes UA trade-off. Additional mandatory requirements apply. Complete the REScheck inspection
Compliance: 26.7% Better Than Code Maximum UA: 1028 Your UA: 754 Maximum SHGC: 0.25 Your SHGC: 0.25
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Envelope Assemblies
Gross Area
Cavity Cont.
Assembly or U-Factor UA
R-Value R-Value
Perimeter
Wall 1: Masonry Block with Integral Insulation 855 17.8 0.0 0.058 43
Window 1: Metal Frame:Single Pane 108 1.070 116
SHGC: 0.25
Wall 2: Masonry Block with Integral Insulation 536 17.8 0.0 0.058 28
Window 1: Metal Frame:Single Pane 48 1.070 51
SHGC: 0.25
Wall 3: Masonry Block with Integral Insulation 720 17.8 0.0 0.058 31
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2017 Florida Building Code,
Energy Conservation requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck
Inspection Checklist.
Section
Plans Verified Field Verified
# Pre-Inspection/Plan Review Complies? Comments/Assumptions
Value Value
& Req.ID
103.1, Construction drawings and Complies Requirement will be met.
103.2 documentation demonstrate Does Not
[PR1]1 energy code compliance for the
Not Observable
building envelope. Thermal
envelope represented on Not Applicable
construction documents.
103.1, Construction drawings and Complies Requirement will be met.
103.2, documentation demonstrate Does Not
403.7, energy code compliance for
Not Observable
403.8 lighting and mechanical systems.
[PR3]1 Systems serving multiple Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr_____ Btu/hr_____ Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: Not Observable
Manual J or other methods Btu/hr_____ Btu/hr_____
approved by the code official. Not Applicable
302.1, Heating and cooling equipment is Heating: Heating: Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr_____ Btu/hr_____ Does Not
[PR2]2 on loads calculated per ACCA Cooling: Cooling: Not Observable
Manual J or other methods Btu/hr_____ Btu/hr_____
approved by the code official. Not Applicable
Refer to R403.7.1 for full details.
Additional Comments/Assumptions:
402.1.2 Slab edge insulation _____ ft _____ ft Complies See the Envelope Assemblies
[FO3]1 depth/length. table for values.
Does Not
Not Observable
Not Applicable
403.9 Snow- and ice-melting system Complies Exception: Requirement is
[FO12]2 controls installed. Does Not not applicable.
Not Observable
Not Applicable
Additional Comments/Assumptions:
402.1.1, Glazing SHGC value (area- SHGC:_____ SHGC:_____ Complies See the Envelope Assemblies
402.3.2, weighted average). table for values.
Does Not
402.3.3
Not Observable
[FR3]1
Not Applicable
402.1.1, Door U-factor. U-_____ U-_____ Complies See the Envelope Assemblies
402.3.4 table for values.
Does Not
[FR1]1
Not Observable
Not Applicable
402.4.1.1 Air barrier and thermal barrier Complies Requirement will be met.
[FR23]1 installed per manufacturer’s Does Not
instructions.
Not Observable
Not Applicable
402.4.3 Fenestration that is not site built Complies Requirement will be met.
[FR20]1 is listed and labeled as meeting Does Not
AAMA /WDMA/CSA 101/I.S.2/A440
Not Observable
or has infiltration rates per NFRC
400 that do not exceed code Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures Complies Requirement will be met.
[FR16]2 sealed at housing/interior finish Does Not
and labeled to indicate ≤2.0 cfm
Not Observable
leakage at 75 Pa.
Not Applicable
403.3.1 Supply and return ducts in attics Complies Requirement will be met.
[FR12]1 insulated >= R-8 where duct is Does Not
>= 3 inches in diameter and >=
Not Observable
R-6 where < 3 inches. Supply and
return ducts in other portions of Not Applicable
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
403.3.5 Building cavities are not used as Complies Requirement will be met.
[FR15]3 ducts or plenums. Does Not
Not Observable
Not Applicable
403.4 HVAC piping conveying fluids R-_____ R-_____ Complies Exception: Requirement is
[FR17]2 above 105 ºF or chilled fluids Does Not not applicable.
below 55 ºF are insulated to ≥R-
Not Observable
3.
Not Applicable
403.4.1 Protection of insulation on HVAC Complies Exception: Requirement is
[FR24]1 piping. Does Not not applicable.
Not Observable
Not Applicable
403.5.3 Hot water pipes are insulated to R-_____ R-_____ Complies Exception: Requirement is
[FR18]2 ≥R-3. Does Not not applicable.
Not Observable
Not Applicable
Additional Comments/Assumptions:
Additional Comments/Assumptions:
Additional Comments/Assumptions:
SECTION A-A
RETURN