FactoryClient User Manual Guide 

 
User manual for FactoryClient v1.1 

Last change date / version: Author:

2020-04-23 v1.0 Leon Vrhovšek


Table of content
Introduction 3

Installation procedure 3

Things you need to provide Plantformance with 7

Reconfiguration procedure 8

Troubleshooting procedure 8

Changing keyboard layout 8

Dead power adapter 8

Extending antenna range 9

2
Introduction

This document describes the basic user manual with installation instructions for the
FactoryClient and the connection for the NFC reader.

1. Installation procedure

Notice: ip address and other parameters are just examples.

1. Step:
- Connect FactoryClient to the power and plug in ethernet cable into the LEFT connection.
Below picture is just information about interface naming in setup script.

2. Step (optional):
- Connect your NFC Reader to one of the USB ports and contact Plantformance AG
Engineer for further information

3
3. Step:
- Power up the FactoryClient and wait until the setup script comes up

4. Step:
When the script comes up :

- 1. Configure hostname from the list

4
- 2. Configure network for the FactoryClient

- IP that FC will use, Netmask and Gateway network (This is not ignition gateway!)

- 3. Wait for results of the connection to the gateway


- The ping should be successful
- Then proceed with setup by clicking ​“No, this is fine”

5
- 4. Configure the IP of FactoryBrain

- Afterwards it should come to the reboot screen and press “Reboot now”.

6
2. Things you need to provide Plantformance with

- Hostname, IP, netmask and gateway you have chosen for this FactoryClient

- Location where this FC is located (like press P1A or oven B2A)

- Serial code of FactoryClient (it's on front of FC picture below for the reference)

7
3. Reconfiguration procedure
In case of changing IP, netmask or gateway you need to change FactoryClient configuration.
- Reboot FactoryClient via GUI or holding down the power button for 5 seconds and
pressing it again.
- Wait until there is text on the screen saying ​"Loading modules up. If you want to
reconfigure networking press the keyboard shortcut that is given in manual."
- Then you need to press 4 button combinations at the same time. The combination is
[CTRL] + [ALT] + [SHIFT] + [P]​.
- After that you should get the configuration screen.
- When configuration is done it will reboot itself into a graphical user interface.

4. Troubleshooting procedure
In the running client that has problems connecting to the FactoryBrain you need to press and
hold the following buttons in sequence. ​[CTRL] + [ALT] + [SHIFT] + [P]
Afterwards follow instructions given by Plantformance.

5. Changing keyboard layout


While client is running
- Go in the right top click on the power button next to the sound button.
- Then press the wrench and screwdriver icon.
- When the general settings window is opened press on the ​Region and language​ icon.
- On the bottom left you see a plus button click it and you get an interface of keyboard
layouts.
- If the keyboard layout is not on the 1st page press the three dots button and find your
layout.
- After you applied you can remove the existing layout by choosing the layout and
pressing minus.

6. Dead power adapter


The client can use 9V-24V DC input. The connector is 5,5*2,5mm. The original has 12V DC
input.

8
7. Extending antenna range
FactoryClient has two RP-SMA (female) connectors on the back side. If you want to extend the
range (FactoryClient in bad position for beacon reception) you need to connect 2 antennas to
the connectors.

You need to buy antennas with RP-SMA (male) connectors.