Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 5

Tidewater Marine East Region (ER)

Date Effective: 01 Apr 2018 Document No:


Title: PSC Guidance Checklist Rev: 00
Approved By: Regional Manager ER-TC-47

SAFETY OF NAVIGATION
ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Charts Are the latest navigation charts provided on-board?      
Are navigation charts for the intended voyage provided on-      
board?
Nautical Publications Are latest nautical publications (tide table, list of lights, list of      
radio signals, etc.) provided on-board?
Are latest corrected supplements of nautical publications      
provided on-board?
Lights, shape, sound- Are navigation lights properly fitted as shown in the drawings?      
signals Is daylight signalling light operating normally?      

RADIO COMMUNICATIONS
ITEM CHECK ITEM SATISFACTORY ACTION
Y N
MF/HF Radio Installation Is MF/HF Radio operating normally      
Is GMDSS Officer familiar with operation (including function      
test) of GMDSS equipment?
Reserve source of energy Is DC operating normally?      

CERTIFICATION OF WATCHKEEPING
ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Endorsement by flag Are STCW certificates endorsed properly by the flag states?      
states
Certificate of Master & Do all crew have valid certificates?      
Officers No expired officer’s certificates?      

SOLAS RELATED OPERATIONAL DEFECTS


ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Tidewater Marine East Region (ER)

Date Effective: 01 Apr 2018 Document No:


Title: PSC Guidance Checklist Rev: 00
Approved By: Regional Manager ER-TC-47

Abandon ship drills Is the abandon ship drill and education, etc. executed?      
Fire drills Is the fire drill and education, etc. executed?      
STABILITY, STRUCTURE AND RELATED EQUIPMENT
ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Emergency Lighting, Is emergency generator/battery operating normally?      
Batteries & Switches Area emergency lights operating normally?      
Beam, Frames, Floors- No wastage of hold frames, beams etc.?      
Corrosion No wastage of longitudinal, transverse webs in WBT??      
Bulkheads-Corrosion No wastage/holes of bulkheads in each compartment?      

LOAD LINES
ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Ventilators, Air Pipes, No wastage/holes in air pipes or ventilators?      
Casings No damage/stuck floats of air pipe head and closing devise?      
Hatch cover, Tarpaulins, No corrosion or wastage of hatch covers/coamings?      
Hatch coaming No damaged or missing cargo securing device?      
Weather tights doors No corrosion or wastage of doors or packing’s?      

MARPOL – ANNEX 1
ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Oil filtering equipment Is oil filtering equipment operating properly      
(Oily-Water Separating No corrosion or wastage of the casing of Oil filtering      
Equipment) equipment?
No corrosion or wastage of the discharge line from Oil filtering      
equipment?
Is maintenance works for piping and Oil filtering equipment      
properly recorded in oil record book?
No by-pass line fitted to oil filtering equipment?      
15ppm alarm Is the 15ppm - alarm arrangement operated normally?      
arrangement Is the automatic stopping device for 15pmm-alarm      
Tidewater Marine East Region (ER)

Date Effective: 01 Apr 2018 Document No:


Title: PSC Guidance Checklist Rev: 00
Approved By: Regional Manager ER-TC-47

arrangement operating normally?

PROPULSION AND AUXILLIARY MACHINERY


ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Cleanliness of Engineer Is the engine room dirty?      
Room
Propulsion main engine No Leakage of fuel oil or lubricating oil from main engine or      
other piping?
LIFE SAVING APPLIANCES
ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Lifeboats Is lifeboat engine operating normally?      
No damage/wastage of shell or equipment?      
Is on-load release gear operating normally? Is on-load release      
gear properly resettled?
Lifeboat Inventory No expired Lifeboat inventory or missing equipment?      
Embarkation No wastage of Embarkation ladder?      
Arrangements for No Damaged lights or cables?      
Survival Craft
Launching Arrangements No corrosion or wastage of Lifeboat davit?      
for Survival Craft No corrosion or wastage of sheaves or hooks?      
Inflatable Life rafts Is there an effective service report kept on-board?      
Are life rafts properly stored?      
Lifebuoys No Wasted Lifebuoys?      
No expired smoke signal or light unit?      
Tidewater Marine East Region (ER)

Date Effective: 01 Apr 2018 Document No:


Title: PSC Guidance Checklist Rev: 00
Approved By: Regional Manager ER-TC-47

FIRE SAFETY MEASURES


ITEM CHECK ITEM SATISFACTORY ACTION
Y N
Fire-Dampers, Valves No corrosion or wastage on the casing of ventilator for engine      
Quick Closing Devices, room
Remote Control, etc. Is the internal damper operating normally?      
Are Emergency shut-off valves on FO tanks operating normally?      
Is delivery pressure normal?      
Is priming pump operating normally?      
No corrosion or wastage of the Fire main?      
No leakage from Fire main in running condition?      
Is isolating valve operating normally?      
Prevention (Fire No damage Fire door?      
protection) Is self-closing device of Fire doors operating normally?      
No damaged fire protection for Escape trunk or door?      
No damaged/missing parts of fire protection material in Engine      
room?
No damage explosive proof lamp?      
Fixed fire extinguisher No wasted CO2 bottles?      
system Is there an effective service report kept on-board?      
Is CO2/Foam tested by air blow or water spray?      
Fire Fighting Equipment Is there an effective service report kept on-board?      
No wasted Fire hose /nozzle?      
Jacketed piping system Are the prevention measures correctly constructed?      
for high pressure fuel Are leakage alarm systems operating normally?
lines
Ready availability of Fire Is a portable fire extinguisher arranged as shown in the      
Fighting Equipment drawing?
Are all hydrants operating normally?      
Tidewater Marine East Region (ER)

Date Effective: 01 Apr 2018 Document No:


Title: PSC Guidance Checklist Rev: 00
Approved By: Regional Manager ER-TC-47

Personal equipment No Wasted Fireman's outfit?      


Is the Cylinder of Breathing Apparatus services properly?      
Fire detection Is fire detection system operating Normally?      