Download as pdf or txt
Download as pdf or txt
You are on page 1of 60

SYSTEM 4000

GMDSS CONSOLE

INSTALLATION
MANUAL
CO4690

Please note:

Any responsibility or liability for loss or damage in connection with the use of this product
and accompanying documentation is disclaimed.

The information in this manual is furnished for informational use only, is subject to change
without notice, may contain errors or inaccuracies, and represents no commitment
whatsoever.

This agreement is governed by the laws of Denmark.

Doc. No.: M4690COM Issue: G/0548

0548
CO4690

CONTENTS

1 GENERAL INFORMATION 1-1

2 INSTALLATION 2-1
2.1 DIMENSIONS AND DRILLING PLAN 2-1
2.2 MECHANICAL INSTALLATION 2-5
2.3 ELECTRICAL INSTALLATION 2-9
2.3.1 JUMPER SETTINGS 2-9
2.3.2 INSTALLATION INTERNAL 250W/500W 2-10
2.3.3 INSTALLATION EXTERNAL 250W/500W 2-14
2.3.4 INSTALLATION INTERNAL 150W 2-26
2.3.5 INSTALLATION EXTERNAL 150W 2-28

3 BATTERY PANEL DESCRIPTION 3-1


3.1 INTRODUCTION 3-1
3.2 OPERATION 3-2
3.3 INSTALLATION 3-3

4 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS 4-1


4.1 COMPONENT LOCATION CONNECTION BOARD 4-1

5 PARTS LISTS 5-1

0437
CO4690

CONTENTS

1 GENERAL INFORMATION 1-1

9844
CO4690

1 GENERAL INFORMATION

With the System 4000 GMDSS console, all the communication equipment of the ship can be combined
in one small, compact console.

One of the main purposes of the console is to make the best possible use of the limited space on board
a ship. Furthermore, the fact that all the equipment is kept in the same place makes installation easy and
fast. Finally, the modular structure of the system means that it can easily be altered if for example a need
to have it extended should arise.

The standard console includes the following: Emergency light, battery panel, loudspeaker, and connec-
tion board. Furthermore, the console is designed with removable front plates for easy service and
maintenance.

The console can be configured to match any maritime communication need. On the following pages,
some typical configurations are shown.

9844
PAGE 1-1
CO4690

CONTENTS

2 INSTALLATION 2-1

2.1 DIMENSIONS AND DRILLING PLAN 2-1

2.2 MECHANICAL INSTALLATION 2-5

2.3 ELECTRICAL INSTALLATION 2-9

2.3.1 JUMPER SETTINGS 2-9

2.3.2 INSTALLATION INTERNAL 250W/500W 2-10

2.3.3 INSTALLATION EXTERNAL 250W/500W 2-14

2.3.4 INSTALLATION INTERNAL 150W 2-26

2.3.5 INSTALLATION EXTERNAL 150W 2-28

0437
CO4690

2 INSTALLATION

2.1 DIMENSIONS AND DRILLING PLAN

CO4690
370 375

405.00

35874

Console without units


CO4690
Weight 16 kg

CO4691

445 375
455

405

35873

Console without units


CO4691
Weight 16 kg

CO4692

845 375
500

455

405

35872

Console without units


CO4692
Weight 28 kg

9843
PAGE 2-1
2 INSTALLATION CO4690

CO4692A

770 375
500

405

35875

Console without units


CO4692A
Weight 28 kg

CO4693A/CO4693B

1170 375
500
405

35877

Console without units


CO4693A/CO4693B
Weight 40 kg

CO4694C

1245 375
500
405

35876B

Console without units


CO4694C
Weight 40 kg

0010
PAGE 2-2
2 INSTALLATION CO4690

TABLETOP MOUNTING

Drilling template Drilling template


for 325mm section. for 400mm section.
280 355
225 300
0
15

65 Cut for cable entry Cut for cable entry


85
115

4 mounting holes (ø6) 4 mounting holes (ø6)

300

375
25 ** 25 **
30 265 340 30
325 400

NB! The table must be sufficiently supported


to carry the GMDSS station.

35846A

** Space from last left- and righthand section to wall.


(22.5 + space = 2.5)

0010
PAGE 2-3
2 INSTALLATION CO4690

BULKHEAD MOUNTING

Drilling template Drilling template


for 325mm section. for 400mm section.
350 425
37.5 250 37.5 250
25
** 225 300 25
**
405

300 * * * *
254
Temporary
Connection board placement Connection board placement mounting holes
temporarily mounted on wall. temporarily mounted on wall.

Earth stubs entry. Earth stubs entry.

100 100
162.5 162.5

35847A
Earth stubs made of steel and
welded to the steel bulkhead.
copper
100mmx0.5mm

10
0m
m
15mm

15mm
40mm
30mm

4 pcs. M6 bolts

* To avoid vibration noise, the console should be fastened with screws on the wall.

** Space from last left- and righthand section to wall.


(22.5 + space = 2.5)

0010
PAGE 2-4
2 INSTALLATION CO4690

2.2 MECHANICAL INSTALLATION

DATA TERMINAL

4 screws M4x10

37209A

0010
PAGE 2-5
2 INSTALLATION CO4690

CONTROL UNITS

0010
PAGE 2-6
2 INSTALLATION CO4690

PAPER ROLL

9843
PAGE 2-7
2 INSTALLATION CO4690

INM-C

0010
PAGE 2-8
2 INSTALLATION CO4690

2.3 ELECTRICAL INSTALLATION

2.3.1 JUMPER SETTINGS

NMEA:
The NMEA signal can be supplied from three different sources:
If the jumpers are placed on S4 and S5, the NMEA signal is supplied to the connected units from an
external unit. The NMEA signal is connected to X36, and then distributed to the units.
If the jumpers are placed on S6 and S7, and the primary Inmarsat C unit is fitted with the GPS option, the
NMEA signal is supplied from the primary Inmarsat C equipment.
If the jumpers are placed on S8 and S9, and the Inmarsat C unit for duplication is fitted with the GPS option,
the NMEA signal is supplied from this unit.

Buffer (option):
If necessary, the NMEA signal can be fed into a buffer.
A buffer OFF jumper is placed in position [1 and 2] on S2 and S3.
A buffer ON jumper is placed in position [2 and 3] on S2 and S3.
To connect the NMEA Buffer Unit to the console: First fasten the NMEA Buffer Unit with four screws right
above the connection board on the right side. Then, by means of the enclosed flat cable, connect the
NMEA Buffer Unit ('Console') to the connection board ('Buffer').

Shunt:
The shunt for the primary equipment can be mounted either internally on the connection board, or
externally in a junction box (part no. 10751370).
When the console is delivered from the factory, the shunt is placed internally, and the jumper S11 should
be placed in position [1 and 2].
If, however, the shunt is placed externally, the jumper should be placed in position [2 and 3]. The 24V
supply for the primary equipment should then be connected to X40 and X41C (charger - and +).

Junction Box X25


Shunt1+ 1
Shunt1- 2
V_Bat1- 3
V_Bat1+ 4

To connection board
x25

V_BAT1+
Fuse
Shunt1+
Fuse

Shunt1-
Fuse
Shunt V_BAT1-
Fuse

Junction box shunt -


x40

To connection board

+
x41

+ - + -

Battery Charger

35901

9915
PAGE 2-9
2 INSTALLATION CO4690

2.3.2 INSTALLATION INTERNAL 250W/500W

INTERNAL CABLES

Cable Description Lenght Connection between Part no. Remarks


(cm)
1 Multicable 120 Speaker - connection board 56.119 Mounted on chassis
2 Power cable Data terminal - connection board Supplied with data terminal
3 Power cable 120 Light switch - connection board 56.120 Mounted on battery panel
4 Power cable Printer - connection board Supplied with printer
5 Power cable Inmarsat C - connection board Supplied with Inmarsat C
6 15 - 15 pole Sub D 120 Inmarsat C - connection board 56.124 100 W mounted in Sub D male
7 TNC female - N male 120 Inmarsat C - aerial 56.116 Mounted on chassis
8 Power cable VHF - connection board Supplied with VHF
9 Multicable 120 VHF option - connection board 56.114 15 pole Sub D HD
10 Multicable 120 VHF SPARC-bus - connection board 56.114 15 pole Sub D HD
16 9 - 9 pole Sub D 120 Battery panel - connection board 56.123 Battery 1
17 9 - 9 pole Sub D 120 Battery panel - connection board 56.123 Battery 2
23 Power cable Printer - connection board Supplied with printer
24 Power cable Data terminal - connection board Supplied with data terminal
25 TNC female - N male 120 Inmarsat C - aerial 56.116 Mounted on chassis
26 Power cable Inmarsat C - connection board Supplied with Inmarsat C
27 15 - 15 pole Sub D 120 Inmarsat C - connection board 56.124 100 W mounted in Sub D male
30 Power cable 120 Emergency light - connection board 56.118 Mounted on chassis
31 9 - 9 pole Sub D 120 MF/HF - connection board 56.123 Scan-bus
32 9 - 9 pole Sub D 120 MF/HF - connection board 56.123 L.S./NMEA
33 Multicable 120 Inmarsat C - connection board 56.121 Inmarsat C on/off
34 Multicable 120 Inmarsat C - connection board 56.121 Inmarsat C on/off
36 9 - 9 pole Sub D 120 Data terminal - connection board 56.123 RS232
37 8 Pole mini Din Printer - paper switch 56.122 Mounted on chassis
38 8 Pole mini Din Printer - paper switch 56.122 Mounted on chassis
39 PL - PL 120 VHF aerial (RX/TX) 527830 Mounted on chassis
41 PL - PL 120 VHF aerial (DSC) 527830 Mounted on chassis
43 9 - 9 pole Sub D Data terminal - Inmarsat C Supplied with data terminal
44 9 - 9 pole Sub D Data terminal - Inmarsat C Supplied with data terminal
45 Centronics - 25 pole Sub D Printer - Inmarsat C / MF/HF Supplied with Printer
46 Centronics - 25 pole Sub D Printer - Inmarsat C Supplied with Printer
47 Telex paper roll 47.830 Supplied with Printer
48 Halogen lamp G4 12V 5W 45.065 Mounted on chassis

0437
PAGE 2-10
2 INSTALLATION CO4690

INTERNAL CABLE OVERVIEW WITH 2 x SAT-C, 250W/500W

Emergency Light Battery Panel


Battery 1 Battery 2

48
Printer
MF/HF 1 30 3 17 16

23 38

32 31 Connection
Board

Black
Printer
Shunt

Black
Green

Data Terminal

37

33 4 2 5 6 9 10 8 34 26 27 46
47

45 On/Off Inm-C 24

25 44

Data Terminal
Keyboard

41 39
VHF
On/Off Inm-C 12V DC

7 43

Keyboard

4-0-35891A

0437
PAGE 2-11
2 INSTALLATION CO4690

INTERNAL CABLES

Cable Description Lenght Connection between Part no. Remarks


(cm)
1 Multicable 120 Speaker - connection board 56.119 Mounted on chassis
2 Power cable Data terminal - connection board Supplied with data terminal
3 Power cable 120 Light switch - connection board 56.120 Mounted on battery panel
4 Power cable Printer - connection board Supplied with printer
5 Power cable Inmarsat C - connection board Supplied with Inmarsat C
6 15 - 15 pole Sub D 120 Inmarsat C - connection board 56.124 100 W mounted in Sub D male
7 TNC female - N male 120 Inmarsat C - aerial 56.116 Mounted on chassis
8 Power cable VHF - connection board Supplied with VHF
9 Multicable 120 VHF option - connection board 56.114 15 pole Sub D HD
10 Multicable 120 VHF SPARC-bus - connection board 56.114 15 pole Sub D HD
16 9 - 9 pole Sub D 120 Battery panel - connection board 56.123 Battery 1
17 9 - 9 pole Sub D 120 Battery panel - connection board 56.123 Battery 2
23 Power cable Printer - connection board Supplied with printer
24 Power cable Data terminal - connection board Supplied with data terminal
25 TNC female - N male 120 Inmarsat C - aerial 56.116 Mounted on chassis
26 Power cable Inmarsat C - connection board Supplied with Inmarsat C
27 15 - 15 pole Sub D 120 Inmarsat C - connection board 56.124 100 W mounted in Sub D male
30 Power cable 120 Emergency light - connection board 56.118 Mounted on chassis
31 9 - 9 pole Sub D 120 MF/HF - connection board 56.123 Scan-bus
32 9 - 9 pole Sub D 120 MF/HF - connection board 56.123 L.S./NMEA
33 Multicable 120 Inmarsat C - connection board 56.121 Inmarsat C on/off
34 Multicable 120 Inmarsat C - connection board 56.121 Inmarsat C on/off
36 9 - 9 pole Sub D 120 Data terminal - connection board 56.123 RS232
37 8 Pole mini Din Printer - paper switch 56.122 Mounted on chassis
38 8 Pole mini Din Printer - paper switch 56.122 Mounted on chassis
39 PL - PL 120 VHF aerial (RX/TX) 527830 Mounted on chassis
41 PL - PL 120 VHF aerial (DSC) 527830 Mounted on chassis
43 9 - 9 pole Sub D Data terminal - Inmarsat C Supplied with data terminal
44 9 - 9 pole Sub D Data terminal - Inmarsat C Supplied with data terminal
45 Centronics - 25 pole Sub D Printer - Inmarsat C / MF/HF Supplied with Printer
46 Centronics - 25 pole Sub D Printer - Inmarsat C Supplied with Printer
47 Telex paper roll 47.830 Supplied with Printer
48 Halogen lamp G4 12V 5W 45.065 Mounted on chassis

0437
PAGE 2-12
2 INSTALLATION CO4690

INTERNAL CABLE OVERVIEW WITH RADIOTELEX + SAT-C, 250W/500W

Emergency Light Battery Panel


Battery 1 Battery 2

48 Printer
MF/HF

1 16 30 3 17

23 38

32 45 31 Connection
Board

Black

Shunt
Printer
Black
Green

Data Terminal

37 34 26 27 46
4 2 36 9 10 8

On/Off Inm-C 24
47

44
25
Keyboard
Data Terminal

41 39
VHF
12V DC

Keyboard
4-0-35915A

0437
PAGE 2-13
2 INSTALLATION CO4690

2.3.3 INSTALLATION 250W Connection between:


EXTERNAL CALLING Cable 29 Cable 34 MF/HF transceiver (TS 3) - connection board (X34)
Connection between: Connection between: Cable dimensions: 2x0.5 mm2 screened
Cable 1 Connection board (X18) - alarm panel (VHF) Connection board (X22) - 24/12V converter Connections:
Connection between: Connectors: NC - SUB-D 9-pole male Cable dimensions: 2x1.5 mm2 min.,screened Signal Transceiver Connection board
Cable dimensions: 2x2x0.5 mm2 screened Max cable length: TS3 X34
MF/HF DSC aerial - MF/HF transceiver DSC/RX
Connections: Max cable length Cable dimensions Nmea RX+ 1 1
Cable dimensions: RG 213/U maximum length 100 m
Alarm panel Connection board Metres mm2 NMEA RX- 2 2
Part no.: 77.508 GND 3 3
Signal SUB-D 9-pole male X18 15 2X1.5
+12V 9 1 Twisted 20 2X2.0
Cable 2 30 2X3.0 Cable 51
0V 2 2 pairs
Connection between: SPARC+ 3 3 Twisted Connection between: MF/HF transceiver (24V bat-
MF/HF aerial coupler - MF/HF transceiver RX/TX Connections:
SPARC- 5 4 pairs tery) - connection board (X40 and X41)
Cable dimensions: RG 213/U maximum length 100 m Signal Connection board N420
Cable dimensions: 2x16 mm2 min.,screened
Part no.: 77.508 X22 24V DC IN
Cable 30 Maximum cable length:
+24V 1 +
Connection between: 0V 2 - Max cable length Cable dimensions
Cable 4 Connection board (X5) - alarm panel (DC supply) Metres mm2
GND 3
Connection between: Cable dimensions: 4x0.5 mm2 screened 11 2X16
MF/HF transceiver(TS10) - connection board (X23) Connections: 17 2X25
Cable dimensions: 5x2x0.5 mm2 screened, maximum Signal Alarm panel Connection board Cable 36
length 100 m SUB-D 9-pole female X5 Cable 57
Connection between:
Connections: +24V 7 1 Connection between:
VHF DSC aerial - VHF DSC/RX
Signal Transceiver Connection board 0V 6 2 MF/HF transceiver (TS2) - connection board (X31)
Cable dimensions: RG 214 maximum length 25 m
TS10 X23 +24V 9 3 Cable dimensions: 2x0.5 mm2 screened
Supply on 1 1 0V 8 4 Connections:
Data+ 2 2 Twisted Cable 37
Signal Transceiver Connection board
Data- 3 3 pairs Cable 31 Connection between:
TS9 X31
AF+ 4 4 Twisted Connection between: VHF aerial - VHF Rx/Tx
AC alarm C 5 1
AF- 5 5 pairs Alarm panel (MF/HF) - connection board (X10) Cable dimensions: RG 214 maximum length 25 m AC alarm C 6 2
0V 6 6 Twisted Connectors: SUB-D 9-pole male - X10 GND 3
+24V 7 7 pairs Cable 44
Cable dimensions: 2x2x0.5 mm2 screened
RXAF+ 8 8 Twisted Connection between: Tranceiver - Aerial coupler
Connections:
RXAF- 9 9 pairs
Signal Alarm panel Connection board
SUB-D 9-pole male X10 Connectors: TS4 - TS4
Cable 7 Cable dimensions: 4x0.5 mm2 screened
+24V 9 1 Twisted
Connection between: 0V 2 2 pairs Connections:
Connection board (X36) - NMEA IN SPARC+ 3 3 Twisted Signal Transceiver Aerial coupler
Cable dimensions: 2x0.5 mm2 screened SPARC- 5 4 pairs TS4 TS4
Connections: +24V 1 1
Signal Connection board Cable 33 RX/TX Protec 2 2
X36 Connection between: TU-ATU Data 3 3
NMEA RX+ 1 GND 4 4
24/12V converter - VHF
NMEA RX- 2
Cable dimensions: 2x2.5+ 1x0.5 mm2
GND 3 Cable 45
Cable length: 1.5 m factory supplied
Connection between:
Connections:
Cable 8 Connection board (X38 and X39) - battery
Signal N420 VHF
AC supply to MF/HF transceiver Cable dimensions: 2x16 mm2 min.,screened
13.2V DC out
Cable dimensions: 3x1.5 mm2 screened On/off On/off 1 Maximum cable length:
Signal Transceiver +13.2V + 2 Max cable length Cable dimensions
TS3 0V - 3 Metres mm2
LINE 1 11 2X16
NEUTRAL 2 17 2X25
GND 3
Cable 50

0548
PAGE 2-14
2 INSTALLATION CO4690

EXTERNAL CABLE OVERVIEW, A2, FLOATING CHARGE AND AC/DC, 250W

RT4822 VHF-DSC SCAN STO DEL


Rx
LOG
ABC 1 DEF 2 GHI 3
Tx
CALL MEM INT-C DW

ADDR
BOOK
JKL 4 MNO 5 PQR 6
TEL /

Tx 1W US CALL ALARM
DSC
STU 7 VWX 8 YZ- 9
FUNC P
SHIFT
* . 0 # 16
ON/OFF DISTRESS

9844
PAGE 2-15
2 INSTALLATION CO4690
Cable 1 Cable 28
Connection between: Connection between: Cable 33 Cable 43
MF/HF DSC aerial - MF/HF transceiver DSC/RX Alarm panel (SAT-C) - connection board (X28) Connection between: Connection between:
Cable dimensions: RG 213/U maximum length 100 m Connectors: SUB-D 9-pole male - X28 24/12V converter - VHF Connection board (X19,21) - EGC printer (X2)
Part no.: 77.508 Cable dimensions: 3x2x0.5 mm2 screened Cable dimensions: 2x2.5+ 1x0.5 mm2 Cable dimensions: 2x0.5 mm2 screened
Connections: Cable length: 1.5 m factory supplied Connections:
Cable 2 Connections: Signal Connection board EGC printer
Alarm panel Connection board
Connection between: Signal SUB-D 9-pole male X28 Signal N420 VHF X21, X19 X2
MF/HF aerial coupler - MF/HF transceiver RX/TX 0V 2 2 Twisted 13.2V DC out ArcNet A 1 7
+9V 9 9 pairs On/off On/off 1 ArcNet B 2 8
Cable dimensions: RG 213/U maximum length 100 m
I/O 3 3 Twisted +13.2V + 2 GND 3 6 or 9
Part no.: 77.508
I/O 6 6 pairs 0V - 3

Cable 4 I/O 4 4 Twisted Cable 44


INPUT 7 7 pairs Cable 34 Connection between:
Connection between:
Connection between: Tranceiver - aerial
MF/HF transceiver(TS10) - connection board (X23) Connection board (X22) - 24/12V converter
Cable dimensions: 5x2x0.5 mm2 screened, maximum Cable 29 Connectors: TS4 - TS4
Connection between: Cable dimensions: 2x1.5 mm2 min.,screened Cable dimensions: 4x0.5 mm2 screened
length 100 m
Connection board (X18) - alarm panel (VHF) Max. cable length: Connections:
Connections:
Connectors: X18 - SUB-D 9-pole male Max cable length Cable dimensions Signal Transceiver Aerial coupler
Signal Transceiver Connection board Metres mm2
TS10 X23 Cable dimensions: 2x2x0.5 mm2 screened TS4 TS4
Connections: 15 2X1.5 +24V 1 1
Supply on 1 1 20 2X2.0
Alarm panel Connection board RX/TX Protec 2 2
Data+ 2 2 Twisted 30 2X3.0
Signal SUB-D 9-pole male X18 TU-ATU Data 3 3
Data- 3 3 pairs
+12V 9 1 Twisted GND 4 4
AF+ 4 4 Twisted Connections:
AF- 5 5 pairs 0V 2 2 pairs Signal Connection board N420
0V 6 6 Twisted SPARC+ 3 3 Twisted X22 24V DC IN Cable 45
+24V 7 7 pairs SPARC- 5 4 pairs +24V 1 + Connection between:
RXAF+ 8 8 Twisted 0V 2 - Connection board (X38 and X39) - battery
RXAF- 9 9 pairs Cable 30 GND 3 Cable dimensions: 2x16 mm2 min.,screened
Connection between: Maximum cable length:
Cable 7 Connection board (X5) - alarm panel (DC supply) Cable 35 Max cable length Cable dimensions
Connection between: Cable dimensions: 4x0.5 mm2 screened Connection between: Metres mm2
Connection board (X36) - NMEA IN Connections: Connection board (X34) - VHF (option) 11 2X16
Cable dimensions: 2x0.5 mm2 screened Signal Alarm panel Connection board Connectors: X34 - SUB-D 15-pole HD male 17 2X25
Connections: SUB-D 9-pole female X5 Cable dimensions: 2x0.5 mm2 screened
SignalConnection board +24V 7 1 Connections: Cable 50
X36 0V 6 2 Signal Connection board VHF Connection between:
NMEA RX+ 1 +24V 9 3 X34 OPTION MF/HF transceiver (TS 3) - connection board (X34)
NMEA RX- 2 0V 8 4 NMEA+ 1 4 Cable dimensions: 2x0.5 mm2 screened
GND 3 NMEA- 2 5 Connections:
Cable 31 GND 3 Signal Transceiver Connection board
Cable 8 Connection between: TS3 X34
AC supply to MF/HF transceiver Alarm panel (MF/HF) - connection board (X10) Cable 36 Nmea RX+ 1 1
Cable dimensions: 3x1.5 mm2 screened Connectors: SUB-D 9-pole male - X10 Connection between: NMEA RX- 2 2
Signal Transceiver Cable dimensions: 2x2x0.5 mm2 screened VHF DSC aerial - VHF DSC/RX GND 3 3
TS3 Connections: Cable dimensions: RG 214, maximum length 25 m
LINE 1 Signal Alarm panel Connection board Part no.: 77.508 Cable 51
NEUTRAL 2 SUB-D 9-pole male X10 Connection between: MF/HF transceiver (24V bat-
GND 3 +24V 9 1 Twisted Cable 37 tery) - connection board (X40 and X41)
0V 2 2 pairs Connection between: Cable dimensions: 2x16 mm2 min.,screened
Cable 16 SPARC+ 3 3 Twisted Maximum cable length:
VHF aerial - VHF Rx/Tx
Connection between: SPARC- 5 4 pairs Max cable length Cable dimensions
Cable dimensions: RG 214, maximum length 25 m
Connection board (X35) - EGC printer (X1) Metres mm2
Cable dimensions: 2x0.5 mm2 screened Cable 32 11 2X16
Cable 41
Connections: Connection between: 17 2X25
Connection between:
Signal Connection board EGC printer Connection board (X27) - VHF (SPARC)
Inmarsat C aerial - Inmarsat C transceiver
X35 X1 Connectors: X27 - SUB-D 15-pole HD male Cable 57
Cable dimensions: RG 214, max. length 40 m
+24V 1 1 Cable dimensions: 3x2x0.5 mm2 twisted pair, screened Connection between:
0V 2 2 Connections: MF/HF transceiver (TS2) - connection board (X31)
GND 3 3 Signal VHF Connection board Cable dimensions: 2x0.5 mm2 screened
Remote on 2 SUB-D 15-pole HD X27 Connections:
Cable 20 SPARC+ 2 (yellow) 3 Twisted Signal Transceiver Connection board
The handset is connected to the Handsetplug at the VHF. SPARC- 3 (yellow/black) 4 pairs TS9 X31
GND 6 (orange) 2 Twisted AC alarm C 5 1
+12V 7 (orange/white) 1 pairs AC alarm C 6 2
0548
PAGE 2-16 GND 6 (red) 2 Twisted GND 3
+12V 10 (black/white) 1 pairs
2 INSTALLATION CO4690

EXTERNAL CABLE OVERVIEW, A2, FLOATING CHARGE AND AC/DC, 250W, 1 x SAT-C

SAT-C Aerial

MF/HF DSC Aerial MF/HF

DSC VHF VHF


Aerial Aerial

HF Aerial
Coupler

ABOVE DECK

41 36 37
Handset

CO4692A
Optional
Tx

CALL
LYNGBY
OXZ

CH 401
FREQ

STATION
Rx
LOG

Tx
CALL
Alarm Panel Optional EGC Printer VHF DSC
SSB TELEPHONY CH ADDR
SIGNAL BOOK SCAN STO DEL
ALARM POWER LOW SQUELCH ON RT4822 VHF-DSC Rx
TEL /
DSC
LOG
ABC 1 DEF 2 GHI 3
Tx
CALL MEM INT-C DW
SCAN STO DEL SQ INT-C 2182
DIST DISTRESS ADDR JKL 4 MNO 5 PQR 6
1 2 3 4 5 BOOK

20
ABC DEF GHI JKL MNO # FREQ

TEL /
PWR DIM SPK ALARM FUNC
SHIFT ON/OFF Tx 1W US CALL ALARM
DSC
STU 7 VWX 8 YZ- 9
PQR 6 STU 7 VWX 8 YZ- 9 . 0 * FUNC P
SHIFT
* . 0 # 16
ON/OFF DISTRESS

Press both keys for 5


seconds to send alarm.

Power Set Login Send Mail Alarm Alarm

ON/OFF

28 29 30 31 16 43
33

V BATTERY 1 A
BATT
1-2
Converter
DIM
BATTERY 2

MUTE/
TEST
EMER-
1 BATTERY 2 1 AC 2
GENCY
ALARM ALARM
LIGHT

24/12V DC

1 2 44 32 35 34

250W MF/HF with Scanning


DSC Watch receiver
AC Supply
Charger 57 50 4 51 45 7

FUSE
50A

BATTERY
4-0-35949A AC SUPPLY NMEA

9844
PAGE 2-17
2 INSTALLATION CO4690

Cable 1 Cable 14 Cable 28 Cable 32


Connection between: Connection between: Connection between: Connection between:
MF/HF DSC aerial - MF/HF transceiver DSC/RX Connection board (X20) - battery charger (X3) Alarm panel (SAT-C) - connection board (X28) Connection board (X27) - VHF (SPARC)
Cable dimensions: RG 213/U maximum length 100 m Cable dimensions: 6x0.5 mm2 screened, maximum Connectors: SUB-D 9-pole male - X28 Connectors: X27 - SUB-D 15-pole HD male
Part no.: 77.508 length 100 m Cable dimensions: 3x2x0.5 mm2 screened Cable dimensions: 3x2x0.5 mm2 twisted pair, screened
Connections: Connections: Connections:
Cable 2 Signal Connection board Power supply/battery charger Alarm panel Connection board Signal VHF Connection board
Connection between: X20 X3 Signal SUB-D 9-pole male X28 SUB-D 15-pole HD X27
MF/HF aerial coupler - MF/HF transceiver RX/TX V BAT+ 1 6 0V 2 2 Twisted SPARC+ 2 (yellow) 3 Twisted
Cable dimensions: RG 213/U maximum length 100 m V BAT- 2 4 +9V 9 9 pairs SPARC- 3 (yellow/black) 4 pairs
Part no.: 77.508 + SHUNT 3 3 I/O 3 3 Twisted GND 6 (orange) 2 Twisted
- SHUNT 4 5 I/O 6 6 pairs +12V 7 (orange/white) 1 pairs
AC ALARM 5 7 I/O 4 4 Twisted GND 6 (red) 2 Twisted
Cable 4 6 INPUT 7 7 pairs +12V 10 (black/white) 1 pairs
Connection between: AC ALARM 7 8
MF/HF transceiver(TS10) - connection board (X23) 8
Cable 29 Cable 33
Cable dimensions: 5x2x0.5 mm2 screened, maximum
length 100 m Connection between: Connection between:
Cable 15 24/12V converter - VHF
Connections: Connection board (X18) - alarm panel (VHF)
AC supply to battery charger Connectors: X18 - SUB-D 9-pole male Cable dimensions: 2x2.5+ 1x0.5 mm2
Signal Transceiver Connection board Cable dimensions: 3x1.5 mm2 screened
TS10 X23 Cable dimensions: 2x2x0.5 mm2 screened Cable length: 1.5 m factory supplied
Signal Battery charger Connections:
Supply on 1 1 Connections:
Data+ 2 2 Twisted Alarm panel Connection board Signal N420 VHF
LINE 1
Data- 3 3 pairs Signal SUB-D 9-pole male X18 13.2V DC out
NEUTRAL 2
AF+ 4 4 Twisted +12V 9 1 Twisted On/off On/off 1
GND 3
AF- 5 5 pairs 0V 2 2 pairs +13.2V + 2
0V 6 6 Twisted SPARC+ 3 3 Twisted 0V - 3
Cable 16 SPARC- 5 4 pairs
+24V 7 7 pairs
Connection between: Cable 34
RXAF+ 8 8 Twisted
RXAF- 9 9 pairs
Connection board (X35) - EGC printer (X1) Cable 30 Connection between:
Cable dimensions: 2x0.5 mm2 screened Connection between: Connection board (X22) - 24/12V converter
Cable 7 Connections: Connection board (X5) - alarm panel (DC supply) Cable dimensions: 2x1.5 mm2 min., screened
Signal Connection board EGC printer Cable dimensions: 4x0.5 mm2 screened Connections:
Connection between:
X35 X1
Connection board (X36) - NMEA IN Connections: Max cable length Cable dimensions
+24V 1 1
Cable dimensions: 2x0.5 mm2 screened Signal Alarm panel Connection board Metres mm2
0V 2 2
Connections: SUB-D 9-pole female X5 15 2X1.5
GND 3 3
Signal Connection board +24V 7 1 20 2X2.0
Remote on 2
X36 0V 6 2 30 2X3.0
NMEA RX+ 1 +24V 9 3
Cable 20 0V 8 4 Connections:
NMEA RX- 2
The handset is connected to the Handset plug at the VHF. Signal Connection board N420
GND 3
X22 24V DC IN
Cable 31
Cable 23 +24V 1 +
Cable 8 Connection between: 0V 2 -
The keyboard is connected to the MF/HF control unit (X4). Alarm panel (MF/HF) - connection board (X10)
AC supply to MF/HF transceiver GND 3
Cable dimensions: 3x1.5 mm2 screened Connectors: SUB-D 9-pole male - X10
Cable 24 Cable dimensions: 2x2x0.5 mm2 screened
Signal Transceiver Cable 35
Connection between: Connections:
TS3 Connection between:
Printer (Data in), MF/HF control unit (X1)
LINE 1 Signal Alarm panel Connection board Connection board (X34) - VHF (option)
NEUTRAL 2 Cable type: Printer cable (Centronic - SUB-D). SUB-D 9-pole male X10
Cable length: 2.0 m factory supplied. Connectors: X34 - SUB-D 15-pole HD male
GND 3 +24V 9 1 Twisted
Part no.: 56.013 Cable dimensions: 2x0.5 mm2 screened
0V 2 2 pairs
Connections:
Cable 11 SPARC+ 3 3 Twisted
Cable 25 SPARC- 5 4 pairs Signal Connection board VHF
Connection between: Battery charger (OUT MF/HF) X34 OPTION
- connection board (X44 and X45) Connection between:
NMEA+ 1 4
Cable dimensions: 2x16 mm2 min.,screened Printer (24V DC) - connection board (X32)
NMEA- 2 5
Maximum cable length: Cable dimensions: 2x1.5 mm2 GND 3
Max cable length Cable dimensions Cable length: 1.5 m factory supplied.
Metres MM² Part no.: 56.066
11 2X16
17 2X25

0548
PAGE 2-18
Cable 36 Cable 50
Connection between: Cable 50 Connection between:
Connection between: HF transceiver (TS 3) - con HF transceiver (TS 3) - connection board (X34)
Cable dimensions: 2x0.5 mm2 screened
VHF DSC aerial - VHF DSC/RX Connections:
Cable dimensions: RG 214 maximum length Signal Transceiver Connection board
25 m TS3 X34
Nmea RX+ 1 1
Cable 37 NMEA RX- 2 2
Connection between: GND 3 3
VHF aerial - VHF Rx/Tx
Cable dimensions: RG 214 maximum length Cable 51
25 m Connection between: MF/HF transceiver (24V
battery) - connection board (X40 and X41)
Cable 41 Cable dimensions: 2x16 mm2 min., screened
Connection between: Maximum cable length:
Inmarsat C 3005M aerial - Inmarsat C trans- Max cable length Cable dimensions
ceiver Metres mm2
11 2X16
Cable dimensions: RG 214 maximum length
17 2X25
40 m
Cable 52
Cable 43
Connection between:
Connection between:
Connection board (X43) - VHF (option)
Connection board (X19,21) - EGC printer (X2)
Connectors: X43-SUB-D 15-pole HD
Cable dimensions: 2x0.5 mm2 screened
male
Connections:
Cable dimensions: 2x0.5 mm2 screened
Signal Connection board EGC printer
Connections:
X21, X19 X2
ArcNet A 1 7
ArcNet B 2 8
GND 3 6.9 Cable 53
Connection between:
Cable 44 Connection board (X29) - 24/12V converter
Connection between: Cable dimensions: 2x1.5 mm2 min., screened
Tranceiver - ATU Max cable length Cable dimensions
Connectors: TS4 - TS4 Metres mm2
Cable dimensions: 4x0.5 mm2 screened 15 2X1.5
20 2X2.0
Connections:
30 2X3.0
Signal Transceiver HF aerial
Connections:
TS4 TS4
Signal Connection board N420
+24V 1 1
X22 24V DC IN
RX/TX Protec 2 2
+24V 1 +
TU-ATU Data 3 3
0V 2 -
GND 4 4
GND 3

Cable 45
Cable 57
Connection between:
Connection between:
Connection board (X38 and X39) - battery
MF/HF transceiver (TS2) - connection board (X31)
Cable dimensions: 2x16 mm2 min., screened
Cable dimensions: 2x0.5 mm2 screened
Maximum cable length:
Connections:
Max cable length Cable dimensions
Signal Transceiver Connection board
Metres mm2
TS2 X31
11 2X16
AC alarm C 5 1
17 2X25
AC alarm C 6 2
GND 3

0548
PAGE 2-19
2 INSTALLATION CO4690

PAGE 2-20
2 INSTALLATION CO4690

EXTERNAL CABLE OVERVIEW, A3, FLOATING CHARGE AND AC/DC, 250W, GMDSS RADIOTELEX + SAT-C

MF/HF DSC Aerial MF/HF SAT-C Aerial

VHF DSC VHF DSC VHF


Aerial Aerial VHF Aerial

HF Aerial
Coupler

ABOVE DECK

Handset Handset

41 36 37 36 37

Optional
Alarm Panel VHF DSC Optional EGC Printer VHF DSC
RT4822 VHF-DSC SCAN STO DEL RT4822 VHF-DSC SCAN STO DEL
Rx Rx
LOG
ABC 1 DEF 2 GHI 3 LOG
ABC 1 DEF 2 GHI 3
Tx Tx
CALL MEM INT-C DW CALL MEM INT-C DW

ADDR JKL 4 MNO 5 PQR 6 ADDR JKL 4 MNO 5 PQR 6

20
BOOK BOOK

Tx 1W US CALL ALARM
TEL /
DSC
STU

SHIFT
7 VWX

FUNC
8 YZ-

P
9 Tx 1W US CALL ALARM
TEL /
DSC
STU

SHIFT
7 VWX

FUNC
8 YZ-

P
9 20
* . 0 # 16 * . 0 # 16
ON/OFF DISTRESS ON/OFF DISTRESS

33 33

Printer CO4692A Converter Converter

Rx
LOG
Tx LYNGBY FREQ
OXZ

CH 401
Tx
STATION CALL
CALL

ALARM
SSB TELEPHONY
POWER LOW SQUELCH ON
SIGNAL
CH ADDR
BOOK

TEL /
24/12V DC 24/12V DC
DSC

SCAN STO DEL SQ INT-C 2182


DIST DISTRESS
ABC 1 DEF 2 GHI 3 JKL 4 MNO 5 # FREQ

PWR DIM SPK ALARM FUNC


SHIFT ON/OFF
PQR 6 STU 7 VWX 8 YZ- 9 . 0 *

1 2 44 Press both keys for 5


seconds to send alarm.

Power Set Login Send Mail Alarm Alarm

ON/OFF

25
24
Keyboard
23
V BATTERY 1 A
BATT
1-2 28 29 30 31 32 35 34 16 43 52 53
DIM
BATTERY 2

MUTE/
TEST
EMER-
1 BATTERY 2 1 AC 2
GENCY
ALARM ALARM
LIGHT

250W MF/HF with Scanning 51 4 57 50 7 14 11


DSC Watch receiver
Telex
AC Supply

Power Supply +
Battery Charger

FUSE
50A

8 45 15

BATTERY

4-0-35951B AC SUPPLY NMEA AC SUPPLY

0548
PAGE 2-21
2 INSTALLATION CO4690

Cable 1 Cable 14 Cable 29 Cable 34


Connection between: Connection between: Connection between: Connection between:
MF/HF DSC aerial - MF/HF transceiver DSC/RX Connection board (X20) - battery charger (X3) Connection board (X18) - alarm panel (VHF) Connection board (X22) - 24/12V converter
Cable dimensions: RG 213/U maximum length 100 m Cable dimensions: 6x0.5 mm2 screened, maximum Connectors: NC - SUB-D 9-pole male Cable dimensions: 2x1.5 mm2 min., screened
Part no.: 77.508 length 100 m Cable dimensions: 2x2x0.5 mm2 screened Connections:
Connections: Connections: Max cable length Cable dimensions
Cable 2 SignalConnection board Power supply/battery charger Alarm panel Connection board Metres mm2
Connection between: X20 X3 Signal SUB-D 9-pole male X18 15 2X1.5
MF/HF aerial coupler - MF/HF transceiver RX/TX V BAT+ 1 6 +12V 9 1 Twisted 20 2X2.0
Cable dimensions: RG 213/U maximum length 100 m V BAT- 2 4 0V 2 2 pairs 30 2X3.0
Part no.: 77.508 + SHUNT 3 3 SPARC+ 3 3 Twisted
Connections:
- SHUNT 4 5 SPARC- 5 4 pairs
AC ALARM 5 7 Signal Connection board N420
Cable 4 6 X22 24V DC IN
Connection between: Cable 30
AC ALARM 7 8 +24V 1 +
MF/HF transceiver(TS10) - connection board (X23) Connection between: 0V 2 -
8
Cable dimensions: 5x2x0.5 mm2 screened, maximum Connection board (X5) - alarm panel (DC supply) GND 3
length 100 m Cable dimensions: 4x0.5 mm2 screened
Cable 15
Connections: Connections: Cable 35
AC supply to battery charger
Signal Transceiver Connection board
Signal Alarm panel Connection board Connection between:
Cable dimensions: 3x1.5 mm2 screened SUB-D 9-pole female X5
TS10 X23 Signal Battery charger Connection board (X34) - VHF (option)
Supply on 1 1 +24V 7 1
Connectors: X34 - SUB-D 15-pole HD male
0V 6 2
Data+ 2 2 Twisted LINE 1 Cable dimensions: 2x0.5 mm2 screened
+24V 9 3
Data- 3 3 pairs NEUTRAL 2 Connections:
0V 8 4
AF+ 4 4 Twisted GND 3 Signal Connection board VHF
AF- 5 5 pairs X34 OPTION
0V 6 6 Twisted Cable 31
Cable 16 NMEA+ 1 4
+24V 7 7 pairs Connection between:
Connection between: NMEA- 2 5
RXAF+ 8 8 Twisted Alarm panel (MF/HF) - connection board (X10) GND 3
RXAF- 9 9 pairs
Connection board (X35) - EGC printer (X1) Connectors: SUB-D 9-pole male - NC
Cable dimensions: 2x0.5 mm2 screened Cable dimensions: 2x2x0.5 mm2 screened
Connections: Cable 36
Cable 7 Connections: Connection between:
Signal Connection board EGC printer
Connection between: Signal Alarm panel Connection board VHF DSC aerial - VHF DSC/RX
X35 X1
Connection board (X36) - NMEA IN SUB-D 9-pole male X10
+24V 1 1 Cable dimensions: RG 214 maximum length 25 m
Cable dimensions: 2x0.5 mm2 screened +24V 9 1 Twisted
0V 2 2
Connections: 0V 2 2 pairs
GND 3 3 Cable 37
SPARC+ 3 3 Twisted
Signal Connection board Remote on 2 Connection between:
X36 SPARC- 5 4 pairs
VHF aerial - VHF Rx/Tx
NMEA RX+ 1 Cable 20
Cable 32 Cable dimensions: RG 214 maximum length 25 m
NMEA RX- 2
The handset is connected to the Handsetplug at the VHF. Connection between:
GND 3
Connection board (X27) - VHF (SPARC) Cable 41
Cable 28 Connection between:
Cable 8 Connectors: X27 - SUB-D 15-pole HD male
Connection between: Cable dimensions: 3x2x0.5 mm2 twisted pair, screened Inmarsat C 3005M aerial - Inmarsat C transceiver
AC supply to MF/HF transceiver
Alarm panel (SAT-C) - connection board (X28) Connections: Cable dimensions: RG 214 maximum length 40 m
Cable dimensions: 3x1.5 mm2 screened
Connectors: SUB-D 9-pole male - X28
Signal Transceiver Signal VHF Connection board
Cable dimensions: 3x2x0.5 mm2 screened Cable 43
TS3 SUB-D 15-pole HD X27
Connections: SPARC+ 2 (yellow) 3 Twisted Connection between:
LINE 1
NEUTRAL 2 Alarm panel Connection board SPARC- 3 (yellow/black) 4 pairs Connection board (X19,21) - EGC printer (X2)
GND 3 Signal SUB-D 9-pole male X28 GND 6 (orange) 2 Twisted Cable dimensions: 2x0.5 mm2 screened
0V 2 2 Twisted +12V 7 (orange/white) 1 pairs Connections:
+9V 9 9 pairs GND 6 (red) 2 Twisted Signal Connection board EGC printer
Cable 11
I/O 3 3 Twisted +12V 10 (black/white) 1 pairs X21, X19 X2
Connection between: Battery charger (OUT MF/HF)
I/O 6 6 pairs ArcNet A 1 7
- connection board (X44 and X45)
I/O 4 4 Twisted Cable 33 ArcNet B 2 8
Cable dimensions: 2x16 mm2 min., screened INPUT 7 7 pairs
Connection between: GND 3 6.9
Maximum cable length:
Max cable length Cable dimensions 24/12V converter - VHF
Metres MM² Cable dimensions: 2x2.5+ 1x0.5 mm2
11 2X16 Cable length: 1.5 m factory supplied
17 2X25 Connections:
Signal N420 VHF
13.2V DC out
On/off On/off 1
+13.2V + 2
0V - 3
0548
PAGE 2-22
2 INSTALLATION CO4690

Cable 44
Connection between: Cable 53
Tranceiver - ATU Connection between:
Connectors: TS4 - TS4 Connection board (X29) - 24/12V converter
Cable dimensions: 4x0.5 mm2 screened Cable dimensions: 2x1.5 mm2 min., screened
Connections: Max cable length Cable dimensions
Signal Transceiver HF aerial Metres mm2
TS4 TS4 15 2X1.5
+24V 1 1 20 2X2.0
RX/TX Protec 2 2 30 2X3.0
TU-ATU Data 3 3 Connections:
GND 4 4 Signal Connection board N420
X22 24V DC IN
Cable 45 +24V 1 +
Connection between: 0V 2 -
Connection board (X38 and X39) - battery GND 3
Cable dimensions: 2x16 mm2 min., screened
Maximum cable length: Cable 57
Max cable length Cable dimensions Connection between:
Metres mm2 MF/HF transceiver (TS9) - connection board (X31)
11 2X16 Cable dimensions: 2x0.5 mm2 screened
17 2X25 Connections:
Signal Transceiver Connection board
Cable 50 TS9 X31
Connection between: AC alarm C 5 1
MF/HF transceiver (TS 3) - connection board (X34) AC alarm C 6 2
Cable dimensions: 2x0.5 mm2 screened GND 3
Connections:
Signal Transceiver Connection board
TS3 X34
Nmea RX+ 1 1
NMEA RX- 2 2
GND 3 3

Cable 51
Connection between: MF/HF transceiver (24V
battery) - connection board (X40 and X41)
Cable dimensions: 2x16 mm2 min., screened
Maximum cable length:
Max cable length Cable dimensions
Metres mm2
11 2X16
17 2X25

Cable 52
Connection between:
Connection board (X43) - VHF (option)
Connectors: X43-SUB-D 15-pole HD
male
Cable dimensions: 2x0.5 mm2 screened
Connections:

0548
PAGE 2-23
2 INSTALLATION CO4690

PAGE 2-24
2 INSTALLATION CO4690

MF/HF DSC Aerial MF/HF SAT-C Aerial SAT-C Aerial

VHF DSC VHF VHF VHF


Aerial Aerial DSC Aerial

HF Aerial
Coupler

ABOVE DECK

Handset Handset

41 41 36 37 36 37

Optional
Alarm Panel VHF DSC Optional EGC Printer VHF DSC
RT4822 VHF-DSC SCAN STO DEL RT4822 VHF-DSC SCAN STO DEL
Rx Rx
LOG
ABC 1 DEF 2 GHI 3 LOG
ABC 1 DEF 2 GHI 3
Tx Tx
CALL MEM INT-C DW CALL MEM INT-C DW

ADDR JKL 4 MNO 5 PQR 6 ADDR JKL 4 MNO 5 PQR 6

20
BOOK BOOK

CO4693B Tx 1W US CALL ALARM


TEL /
DSC
STU

SHIFT
7 VWX

FUNC
8 YZ-

P
9 Tx 1W US CALL ALARM
TEL /
DSC
STU

SHIFT
7 VWX

FUNC
8 YZ-

P
9 20
* . 0 # 16 * . 0 # 16
ON/OFF DISTRESS ON/OFF DISTRESS

Rx
LOG
Tx LYNGBY FREQ
OXZ

CH 401
Tx
STATION CALL
CALL

SSB TELEPHONY CH ADDR


SIGNAL BOOK

33
ALARM POWER LOW SQUELCH ON

33
TEL /
DSC

SCAN STO DEL SQ INT-C 2182


DIST DISTRESS
ABC 1 DEF 2 GHI 3 JKL 4 MNO 5 # FREQ

PWR DIM SPK ALARM FUNC


SHIFT ON/OFF
PQR 6 STU 7 VWX 8 YZ- 9 . 0 *

Press both keys for 5


Converter Converter
seconds to send alarm.

Power Set Login Send Mail Alarm Alarm

ON/OFF

Press both keys for 5


seconds to send alarm.

Power Set Login Send Mail Alarm Alarm 24/12V DC 24/12V DC


ON/OFF

BATT
V BATTERY 1 A 1-2

DIM
BATTERY 2

MUTE/
TEST
EMER-
1 BATTERY 2 1 AC 2
GENCY
ALARM ALARM
LIGHT

28 29 30 31 32 35 34 16 43 52 53

1 2 44

250W MF/HF with Scanning


DSC Watch receiver
AC Supply
50 4 57 51 7 14 11

Power supply +
Battery Charger

FUSE
50A

8 45 15

BATTERY
4-0-35950B AC SUPPLY NMEA AC SUPPLY

0548
PAGE 2-25
2.3.4 INSTALLATION INTERNAL 150W

INTERNAL CABLES

Cable Description Lenght Connection between Part no. Remarks


(cm)
1 Multicable 120 Speaker - connection board 56.119 Mounted on chassis
2 Power cable Data terminal - connection board Supplied with data terminal
3 Power cable 120 Light switch - connection board 56.120 Mounted on battery panel
4 Power cable Printer - connection board Supplied with printer
5 Power cable Inmarsat C - connection board Supplied with Inmarsat C
6 15 - 15 pole Sub D 120 Inmarsat C - connection board 56.124 100 W mounted in Sub D male
7 TNC female - N male 120 Inmarsat C - aerial 56.116 Mounted on chassis
8 Power cable VHF - connection board Supplied with VHF
9 Multicable 120 VHF option - connection board 56.114 15 pole Sub D HD
10 Multicable 120 VHF SPARC-bus - connection board 56.114 15 pole Sub D HD
16 9 - 9 pole Sub D 120 Battery panel - connection board 56.123 Battery 1
17 9 - 9 pole Sub D 120 Battery panel - connection board 56.123 Battery 2
23 Power cable Printer - connection board Supplied with printer
24 Power cable Data terminal - connection board Supplied with data terminal
25 TNC female - N male 120 Inmarsat C - aerial 56.116 Mounted on chassis
26 Power cable Inmarsat C - connection board Supplied with Inmarsat C
27 15 - 15 pole Sub D 120 Inmarsat C - connection board 56.124 100 W mounted in Sub D male
30 Power cable 120 Emergency light - connection board 56.118 Mounted on chassis
31 9 - 9 pole Sub D 120 MF/HF - connection board 56.123 Scan-bus
33 Multicable 120 Inmarsat C - connection board 56.121 Inmarsat C on/off
34 Multicable 120 Inmarsat C - connection board 56.121 Inmarsat C on/off
36 9 - 9 pole Sub D 120 Data terminal - connection board 56.123 RS232
37 8 Pole mini Din Printer - paper switch 56.122 Mounted on chassis
38 8 Pole mini Din Printer - paper switch 56.122 Mounted on chassis
39 PL - PL 120 VHF aerial (RX/TX) 527830 Mounted on chassis
41 PL - PL 120 VHF aerial (DSC) 527830 Mounted on chassis
43 9 - 9 pole Sub D Data terminal - Inmarsat C Supplied with data terminal
44 9 - 9 pole Sub D Data terminal - Inmarsat C Supplied with data terminal
45 Centronics - 25 pole Sub D Printer - Inmarsat C / MF/HF Supplied with Printer
46 Centronics - 25 pole Sub D Printer - Inmarsat C Supplied with Printer
47 Telex paper roll 47.830 Supplied with Printer
48 Halogen lamp G4 12V 5W 45.065 Mounted on chassis
49 9 - 9 Pole Sub D 120 MF/HF - connection board 56.184 L.S./NMEA

0437
PAGE 2-26
2 INSTALLATION CO4690

INTERNAL CABLE OVERVIEW, WITH 2 x SAT-C, MF/HF 150W

Emergency Light Battery Panel


Battery 1 Battery 2

48
Printer
MF/HF 150W 1 30 3 17 16

23 38

49 31 Connection
Board

Black
Printer
Shunt

Black
Green

Data Terminal

37

33 4 2 5 6 9 10 8 34 26 27 46
47

45 On/Off Inm-C 24

25 44

Data Terminal Keyboard

41 39
VHF
On/Off Inm-C 12V DC

7 43

Keyboard

39565

0437
PAGE 2-27
2 INSTALLATION CO4690

2.3.4 INSTALLATION EXTERNAL 150W Cable 15 Cable 29 Cable 33


AC supply to battery charger Connection between: Connection between:
Cable 1 Cable dimensions: 3x1.5 mm2 screened Connection board (X18) - alarm panel (VHF) 24/12V converter - VHF
Connection between: Signal Battery charger Connectors: NC - SUB-D 9-pole male Cable dimensions: 2x2.5+ 1x0.5 mm2
MF/HF DSC aerial - MF/HF transceiver DSC/RX Cable dimensions: 2x2x0.5 mm2 screened Cable length: 1.5 m factory supplied
Cable dimensions: RG 213/U maximum length 100 m LINE 1 Connections: Connections:
NEUTRAL 2 Alarm panel Connection board Signal N420 VHF
Part no.: 77.508
GND 3 Signal SUB-D 9-pole male X18 13.2V DC out
Cable 2 +12V 9 1 Twisted On/off On/off 1
Cable 16 0V 2 2 pairs +13.2V + 2
Connection between:
Connection between: SPARC+ 3 3 Twisted 0V - 3
MF/HF aerial coupler - MF/HF transceiver RX/TX
Connection board (X35) - EGC printer (X1) SPARC- 5 4 pairs
Cable dimensions: RG 213/U maximum length 100 m
Cable dimensions: 2x0.5 mm2 screened Cable 34
Part no.: 77.508
Connections: Cable 30 Connection between:
Signal Connection board EGC printer Connection between: Connection board (X22) - 24/12V converter
Cable 4
X35 X1 Connection board (X5) - alarm panel (DC supply) Cable dimensions: 2x1.5 mm2 min., screened
Connection between: +24V 1 1 Cable dimensions: 4x0.5 mm2 screened Connections:
MF/HF transceiver(TS10) - connection board (X23) 0V 2 2 Connections: Max cable length Cable dimensions
Cable dimensions: 5x2x0.5 mm2 screened, maximum GND 3 3 Signal Alarm panel Connection board Metres mm2
length 100 m Remote on 2 SUB-D 9-pole female X5 15 2X1.5
Connections: +24V 7 1 20 2X2.0
Signal Transceiver Connection board Cable 20 0V 6 2 30 2X3.0
TS10 X23 The handset is connected to the Handsetplug at the VHF. +24V 9 3
Supply on 1 1 0V 8 4 Connections:
Data+ 2 2 Twisted Signal Connection board N420
Cable 23
Data- 3 3 pairs X22 24V DC IN
The keyboard is connected to the MF/HF control unit (X4). Cable 31
AF+ 4 4 Twisted +24V 1 +
Connection between:
AF- 5 5 pairs 0V 2 -
Cable 24 Alarm panel (MF/HF) - connection board (X10) GND 3
0V 6 6 Twisted
+24V 7 7 pairs
Connection between: Connectors: SUB-D 9-pole male - NC
RXAF+ 8 8 Twisted Printer (Data in), MF/HF control unit (X1) Cable dimensions: 2x2x0.5 mm2 screened Cable 35
RXAF- 9 9 pairs Cable type: Printer cable (Centronic - SUB-D). Connections: Connection between:
Cable length: 2.0 m factory supplied. Signal Alarm panel Connection board Connection board (X34) - VHF (option)
Cable 7 Part no.: 56.013 SUB-D 9-pole male X10
Connectors: X34 - SUB-D 15-pole HD male
+24V 9 1 Twisted
Connection between: Cable dimensions: 2x0.5 mm2 screened
Cable 25 0V 2 2 pairs
Connection board (X36) - NMEA IN Connections:
Connection between: SPARC+ 3 3 Twisted
Cable dimensions: 2x0.5 mm2 screened SPARC- 5 4 pairs Signal Connection board VHF
Connections: Printer (24V DC) - connection board (X32) X34 OPTION
Signal Connection board Cable dimensions: 2x1.5 mm2 NMEA+ 1 4
Cable length: 1.5 m factory supplied. Cable 32
X36 NMEA- 2 5
Part no.: 56.066 Connection between: GND 3
NMEA RX+ 1
NMEA RX- 2
Connection board (X27) - VHF (SPARC)
GND 3 Cable 28 Connectors: X27 - SUB-D 15-pole HD male Cable 36
Connection between: Cable dimensions: 3x2x0.5 mm2 twisted pair, screened Connection between:
Cable 8 Alarm panel (SAT-C) - connection board (X28) Connections: VHF DSC aerial - VHF DSC/RX
AC supply to MF/HF transceiver Connectors: SUB-D 9-pole male - NC Signal VHF Connection board Cable dimensions: RG 214 maximum length 25 m
Cable dimensions: 3x1.5 mm2 screened SUB-D 15-pole HD X27
Cable dimensions: 3x2x0.5 mm2 screened
SPARC+ 2 (yellow) 3 Twisted
Signal Transceiver Connections: Cable 37
SPARC- 3 (yellow/black) 4 pairs
TS3 Alarm panel Connection board Connection between:
GND 6 (orange) 2 Twisted
LINE 1 Signal SUB-D 9-pole male X28 VHF aerial - VHF Rx/Tx
+12V 7 (orange/white) 1 pairs
NEUTRAL 2 0V 2 2 Twisted Cable dimensions: RG 214 maximum length 25 m
GND 6 (red) 2 Twisted
GND 3 +9V 9 9 pairs +12V 10 (black/white) 1 pairs Part no.: 77.508
I/O 3 3 Twisted
Cable 11 I/O 6 6 pairs Cable 41
Connection between: Battery charger (OUT MF/HF) I/O 4 4 Twisted
Connection between:
- connection board (X44 and X45) INPUT 7 7 pairs
Inmarsat C 3005M aerial - Inmarsat C transceiver
Cable dimensions: 2x16 mm2 min., screened Cable dimensions: RG 214 maximum length 40 m
Maximum cable length:
Max cable length Cable dimensions
Metres MM²
11 2X16
17 2X25

0548
PAGE 2-28
2 INSTALLATION CO4690

Cable 43 Cable 53
Connection between: Connection between:
Connection board (X19,21) - EGC printer (X2) Connection board (X29) - 24/12V converter
Cable dimensions: 2x0.5 mm2 screened Cable dimensions: 2x1.5 mm2 min., screened
Connections: Max cable length Cable dimensions
Signal Connection board EGC printer Metres mm2
X21, X19 X2 15 2X1.5
ArcNet A 1 7 20 2X2.0
ArcNet B 2 8 30 2X3.0
GND 3 6.9 Connections:
Signal Connection board N420
Cable 44 X22 24V DC IN
Connection between: +24V 1 +
Tranceiver - ATU 0V 2 -
GND 3
Connectors: TS4 - TS4
Cable dimensions: 4x0.5 mm2 screened
Connections: Cable 57
Connection between:
Signal Transceiver HF aerial
TS4 TS4 MF/HF transceiver (TS2) - connection board (X31)
+24V 1 1 Cable dimensions: 2x0.5 mm2 screened
RX/TX Protec 2 2 Connections:
TU-ATU Data 3 3 Signal Transceiver Connection board
GND 4 4 TS2 X31
AC alarm C 5 1
Cable 45 AC alarm C 6 2
Connection between: GND 3
Connection board (X38 and X39) - battery
Cable dimensions: 2x16 mm2 min., screened Cable 59
Maximum cable length: Connection between:
Max cable length Cable dimensions Connection board (X20) - shunt box
Metres mm2 Cable dimensions: 4x0.5 mm2 screened, maxi-
11 2X16 mum length 100 m
17 2X25 Connections:

Signal Connection board Shunt box


Cable 50
X20
Connection between:
V BAT+ 1 6
MF/HF transceiver (TS 3) - connection board (X34) V BAT- 2 5
Cable dimensions: 2x0.5 mm2 screened + SHUNT 3 2
Connections: V MES- 4 4
Signal Transceiver Connection board
TS3 X34
Nmea RX+ 1 1 Cable 60
NMEA RX- 2 2 Connection between:
GND 3 3 Connection board (X20) - charger
Cable dimensions: 2x0.5 mm2 screened, maxi-
Cable 51 mum length 100 m
Connection between: MF/HF transceiver (24V Connections:
battery) - connection board (X40 and X41)
Signal Connection board Charger
Cable dimensions: 2x16 mm2 min., screened
X20 X4
Maximum cable length:
AC ALARM 5 3
Max cable length Cable dimensions AC ALARM 7 4
Metres mm2
11 2X16
17 2X25

Cable 52
Connection between:
Connection board (X43) - VHF (option)
Connectors: NC-SUB-D 15-pole HD male
Cable dimensions: 2x0.5 mm2 screened
Connections:

0548
PAGE 2-29
2 INSTALLATION CO4690

0437
PAGE 2-30
2 INSTALLATION CO4690

EXTERNAL CABLE OVERVIEW, A3, FLOATING CHARGE AND AC/DC, 150W, 2 x SAT-C

MF/HF DSC Aerial MF/HF


SAT-C SAT-C
ANTENNA ANTENNA
VHF DSC VHF VHF VHF
Aerial Aerial Aerial Aerial

HF Aerial
Coupler

ABOVE DECK

Handset Handset

36 37 41 41 36 37

Optional
VHF DSC Alarm Panel Optional EGC Printer VHF DSC
RT4822 VHF-DSC SCAN STO DEL RT4822 VHF-DSC SCAN STO DEL
Rx Rx
LOG
ABC 1 DEF 2 GHI 3 LOG
ABC 1 DEF 2 GHI 3
Tx Tx
CALL MEM INT-C DW CALL MEM INT-C DW

ADDR JKL 4 MNO 5 PQR 6 ADDR JKL 4 MNO 5 PQR 6

20
BOOK BOOK

Tx 1W US CALL ALARM
TEL /
DSC
STU

SHIFT
7 VWX

FUNC
8 YZ-

P
9
CO4693B Tx 1W US CALL ALARM
TEL /
DSC
STU

SHIFT
7 VWX

FUNC
8 YZ-

P
9 20
* . 0 # 16 * . 0 # 16
ON/OFF DISTRESS ON/OFF DISTRESS

Rx
LOG
Tx LYNGBY FREQ
OXZ

CH 401
Tx
STATION CALL
CALL

SSB TELEPHONY CH ADDR


SIGNAL BOOK

33
ALARM POWER LOW SQUELCH ON

33
TEL /
DSC

SCAN STO DEL SQ INT-C 2182


DIST DISTRESS
ABC 1 DEF 2 GHI 3 JKL 4 MNO 5 # FREQ

PWR DIM SPK ALARM FUNC


SHIFT ON/OFF
PQR 6 STU 7 VWX 8 YZ- 9 . 0 *

Converter Press both keys for 5


Converter
seconds to send alarm.

Power Set Login Send Mail Alarm Alarm

ON/OFF

Press both keys for 5


seconds to send alarm.

24/12V DC Power Set Login Send Mail Alarm Alarm 24/12V DC


ON/OFF

BATT
V BATTERY 1 A 1-2

DIM
BATTERY 2

MUTE/
TEST
EMER-
1 BATTERY 2 1 AC 2
GENCY
ALARM ALARM
LIGHT

32 35 34 28 29 30 31 16 43 52 53

1 2

150W MF/HF with Scanning


DSC Watch receiver 4 51 7 11 11 59 60
AC Supply

PS4655 CH4656 PS4655


AC Power supply Battery charger AC Power supply

Shunt Box

FUSE
50A

45

BATTERY
4-0-39563A NMEA AC SUPPLY AC SUPPLY AC SUPPLY

0548
PAGE 2-31
CO4690

CONTENTS

3 BATTERY PANEL DESCRIPTION 3-1

3.1 INTRODUCTION 3-1

3.2 OPERATION 3-2

3.3 INSTALLATION 3-3

9851
CO4690

3 BATTERY PANEL DESCRIPTION

3.1 INTRODUCTION

GENERAL DESCRIPTION

The Battery Panel is used for monitoring the accumulator battery of the reserve supply arrangement for
the radio installations. Battery voltage and current are displayed on digital panel meters, and visual and
audible alarms are incorporated for warning of high/low battery voltage and failure of AC supply.

The Battery Panel is intended for installations with one or two batteries (determined by internal jumper
setting) and one or two battery chargers. It contains separate alarm lamps for indication of high/low battery
voltage for each battery, and separate alarm lamps for indication of AC supply failure for each battery
charger. With a push button switch it is possible to switch the panel meters between monitoring battery
1 and battery 2 in two battery installations.

All units include dimmer, mute and test functions. The displays and keyboard are backlight illuminated.

The Battery Panel must be connected to a DC supply voltage of 21.6V to 31.2V, normally the + 24V DC
from the AC Power Supply/Charger. In installations with two AC Power Supply/Chargers, the Battery
Panel contains an automatic switch which secures supply voltage as long as just one of the AC Power
Supply/Chargers are operating.

For current measurements the Battery Panel should be connected to the AC Power Supply/Charger or
Junction Box Shunt containing fuses and a shunt resistor.

The voltage and current meters are supplied from the battery itself and will operate down to a battery
voltage of 10 V. The audible alarm and visual indicators are supplied from the + 24 V DC of the AC Power
Supply/Charger allowing low voltage alarm in case of battery failure.

TECHNICAL DATA

High voltage alarm


Threshold voltage: Adjustable from 24V to 33V
Factory preset to 29,5V ±2%

Low voltage alarm


Threshold voltage: Adjustable from 20.5V to 24.0V
Factory preset to 23.5V ±2%

AC-alarm
Input type selectable between relay contact or voltage input.

Relay contact:
“No Alarm” ~ open circuit
“Alarm” ~ short circuit
(Open circuit voltage: 1.2V, Short circuit current: 6mA)

Voltage input:
No Alarm” 24V DC nom.
“Alarm” 0V DC
(Input current at 24 V DC: 6mA)

The selection between Relay contact or Voltage input is determined by jumper setting. See ’Installation’.
Factory preset: Relay contact

Alarm sound mute time


10 min. or infinite is selected by internal jumper setting. See ‘Installation’.
Factory preset: infinite

9851
PAGE 3-1
3 BATTERY PANEL DESCRIPTION CO4690

Voltmeter
3 ½ digit
Resolution: 0.1V
Accuracy: ±4% typically
Measuring range: +10 to +40V
Sensitivity: 1V/V

Current Meter
3 ½ digit
Resolution: 0.1Amp
Accuracy: < ± 10% of meter reading
Measuring range: ±200 Amp
Sensitivity: 100mV/Amp

Compass safe distance


Standard: 0.9 m. Steering: 0.6 m.

3.2 OPERATION

Mute the alarm sound


The alarm sound is muted by pressing ‘MUTE/TEST’.
A new event will reactivate the alarm sound.

Switch between batteries


To switch between Battery 1 and Battery 2, press ‘BATT 1-2’ briefly. Applicable for 2 battery installations.

Test the Charger Panel


Press ‘MUTE/TEST’ for 2 seconds to initiate a self test.
All lamps, backlight and alarm sound are activated.

Adjust the light intensity


Press ‘DIM’ to adjust the light intensity.
The dimmer button controls the intensity of the lamps and backlight in four levels. The light in the alarm
lamps can not be turned fully off.

9851
PAGE 3-2
3 BATTERY PANEL DESCRIPTION CO4690

3.3 INSTALLATION

ADJUSTMENTS

Figure is not available at this stage.


Refer to figure at page 3-4

Adjustment of High voltage alarm threshold for Battery 1:


1. Apply an input voltage set to the wanted threshold value to the terminals ‘+ VBAT’ and ‘- VBAT’.
2. Adjust R84 (see figure pos. 1) until high battery alarm is indicated.
3. Decrease the input voltage by 0.5V and check that the alarm stops. If not repeat the adjustment.

Adjustment of Low voltage alarm threshold for Battery 1:


1. Apply an input voltage set to the wanted threshold value to the terminals ‘+ VBAT’ and ‘- VBAT’.
2. Adjust R83 (see figure pos. 2) until low battery alarm is indicated.
3. Increase the input voltage by 0.5V and check that the alarm stops. If not repeat the adjustment.

Adjustment of High voltage alarm threshold for Battery 2:


1. Apply an input voltage set to the wanted threshold value to the terminals ‘+ VBAT’ and ‘- VBAT’.
2. Adjust R94 (see figure pos. 3) until high battery alarm is indicated.
3. Decrease the input voltage by 0.5V and check that the alarm stops. If not repeat the adjustment.

Adjustment of Low voltage alarm threshold for Battery 2:


1. Apply an input voltage set to the wanted threshold value to the terminals ‘+ VBAT’ and ‘- VBAT’.
2. Adjust R95 (see figure pos. 4) until low battery alarm is indicated.
3. Increase the input voltage by 0.5V and check that the alarm stops. If not repeat the adjustment.

9902
PAGE 3-3
3 BATTERY PANEL DESCRIPTION CO4690

JUMPER SETTINGS

Dismantling instructions are not available at this stage.

5 6 3 2 1

5

6 6 6 6
5

5

6

6

5

7 8 4

Setting of AC alarm 1 input type:


On the figure jumpers S3 and S7 ( pos. 5) are shown in the relay contact position.
1. To change to the voltage input both S3 and S7 must be set to the oposite position
2. Apply an input voltage to the X1 terminals ‘AC Alarm V’ and
‘AC Alarm C’.
3. Check that no voltage gives alarm and that the alarm stops when 24V DC is applied.

Setting of AC alarm 2 input type:


On the figure jumpers S4 and S6 ( pos. 6) are shown in the relay contact position.
1. To change to the voltage input both S4 and S6 must be set to the oposite position
2. Apply an input voltage to the X2 terminals ‘AC Alarm V’ and
‘AC Alarm C’.
3. Check that no voltage gives alarm and that the alarm stops when 24V DC is applied.

Setting of single or dual battery:


On the figure jumper S8 ( pos. 7) is shown in dual battery position.
1. To change to single battery the jumper S8 must be set to the oposite position.
2. Check that the battery shift function is inhibited.

Setting the mute time:


On the figure jumper S5 ( pos. 8) is shown in infinite mute time position.
1. To change mute time to 10 minuttes the jumper S5 must be set to the oposite position.

9851
PAGE 3-4
CO4690

CONTENTS

4 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS 4-1

4.1 COMPONENT LOCATION CONNECTION BOARD 4-1

9851
CO4690

4 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS

4.1 COMPONENT LOCATION CONNECTION BOARD

Seen from component side with upper side tracks.

PCB rev. 33741D

9844
PAGE 4-1
4 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS CO4690

COMPONENT LOCATION CONNECTION BOARD

Seen from component side with silkscreen.

PCB rev. 33741D

9902
PAGE 4-2
4 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS CO4690

CONNECTION BOARD

This diagram is valid for PCB rev. 33741D

9844
PAGE 4-3
4 CIRCUIT DESCRIPTION AND SCHEMATIC DIAGRAMS CO4690

CONNECTION BOARD

This diagram is valid for PCB rev. 33741D

9844
PAGE 4-4
CO4690

CONTENTS

5 PARTS LISTS 5-1

9851
CO4690

5 PARTS LISTS
CONNECTION BOARD 33741 T&T 5-6-33741D / 4-0-33741C 633741

POSITION DESCRIPTION MANUFACTURER TYPE PART NO.

F1 ATO BLADE FUSE 10AF RED COLOURED RED LITTELFUSE 257010 45.663
F2 ATO BLADE FUSE 10AF RED COLOURED RED LITTELFUSE 257010 45.663
F3 ATO BLADE FUSE 5AF COLOURED TAN LITTELFUSE 257005 45.661
F4 ATO BLADE FUSE 5AF COLOURED TAN LITTELFUSE 257005 45.661
F5 ATO BLADE FUSE 10AF RED COLOURED RED LITTELFUSE 257010 45.663
F6 ATO BLADE FUSE 10AF RED COLOURED RED LITTELFUSE 257010 45.663
F7 ATO BLADE FUSE 15AF COLOURED BLUE LITTELFUSE 257015 45.664
F8 ATO BLADE FUSE 15AF COLOURED BLUE LITTELFUSE 257015 45.664
F9 ATO BLADE FUSE 10AF RED COLOURED RED LITTELFUSE 257010 45.663
F10 ATO BLADE FUSE 10AF RED COLOURED RED LITTELFUSE 257010 45.663
F11 ATO BLADE FUSE 5AF COLOURED TAN LITTELFUSE 257005 45.661
F12 ATO BLADE FUSE 5AF COLOURED TAN LITTELFUSE 257005 45.661
F13 ATO BLADE FUSE 15AF COLOURED BLUE LITTELFUSE 257015 45.664
F14 ATO BLADE FUSE 15AF COLOURED BLUE LITTELFUSE 257015 45.664
F15 FUSE TIME LAG 1A PCB VERSION TYPE TR5 ELU 166 050 1AT 45.722
F16 FUSE TIME LAG 1A PCB VERSION TYPE TR5 ELU 166 050 1AT 45.722
F17 FUSE TIME LAG 1A PCB VERSION TYPE TR5 ELU 166 050 1AT 45.722
F18 FUSE TIME LAG 1A PCB VERSION TYPE TR5 ELU 166 050 1AT 45.722
F19 FUSE TIME LAG 1A PCB VERSION TYPE TR5 ELU 166 050 1AT 45.722
F20 FUSE TIME LAG 1A PCB VERSION TYPE TR5 ELU 166 050 1AT 45.722
F21 FUSE TIME LAG 1A PCB VERSION TYPE TR5 ELU 166 050 1AT 45.722
F22 FUSE TIME LAG 1A PCB VERSION TYPE TR5 ELU 166 050 1AT 45.722
X1 PLUG 2POLES MOLEX 39-28-1023 78.215
X2 SOCKET PCB VERSION 2x5 POLES u-MATCH AMP 1-215079-0 78.194
X3 PLUG 4 POLES MOLEX 39-28-1043 78.216
X4 TERMINAL BLOCK PCB VERS. 6 POLES 1.5mm2 WAGO 236-406 81.136
X5 TERMINAL BLOCK PCB VERS. 4 POLES 1.5mm2 WAGO 236-404 81.134
X6 SOCKET 9 POLES SUB-D IB OBEL PEDERS. NS-DMS-09SBTS-S1 78.176
X7 PLUG SUB D 9 POLES PCB VERSION ASSMANN A-DS 09 PP 78.137
X8 PLUG SUB-D 15POL PCB VERSION CONEC CDS 15 PFSN 78.694
X9 PLUG MT 4 POLES AMP 0-826375-4 78.104
X10 TERMINAL BLOCK PCB VERS. 4 POLES 1.5mm2 WAGO 236-404 81.134
X11 SOCKET 9 POLES SUB-D IB OBEL PEDERS. NS-DMS-09SBTS-S1 78.176
X12 PLUG SUB-D 15POL PCB VERSION CONEC CDS 15 PFSN 78.694
X13 PLUG 2POLES MOLEX 39-28-1023 78.215
X14 PLUG SUB D 9 POLES PCB VERSION ASSMANN A-DS 09 PP 78.137
X15 SOCKET 9 POLES SUB-D IB OBEL PEDERS. NS-DMS-09SBTS-S1 78.176
X16 CONNECTION ELEMENT FOR M5 SCREW T&T 1-0-25860 225860
X17 TERMINAL BLOCK PCB VERS. 4 POLES 1.5mm2 WAGO 236-404 81.134
X18 TERMINAL BLOCK PCB VERS. 4 POLES 1.5mm2 WAGO 236-404 81.134
X19 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X20 TERMINAL BLOCK PCB VERS. 8 POLES 1.5mm2 WAGO 236-408 81.138
X21 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X22 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X23 TERMINAL BLOCK PCB VERS. 9 POLES 1.5mm2 WAGO 236-409 81.139
X24 TERMINAL BLOCK PCB VERS. 4 POLES 1.5mm2 WAGO 236-404 81.134
X25 TERMINAL BLOCK PCB VERS. 4 POLES 1.5mm2 WAGO 236-404 81.134
X26 TERMINAL BLOCK PCB VERS. 4 POLES 1.5mm2 WAGO 236-404 81.134
X27 TERMINAL BLOCK PCB VERS. 4 POLES 1.5mm2 WAGO 236-404 81.134
X28 TERMINAL BLOCK PCB VERS. 9 POLES 1.5mm2 WAGO 236-409 81.139
X29 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X30 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X31 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X32 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X33 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X34 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X35 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X36 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X37 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X38 CONNECTION ELEMENT FOR M5 SCREW T&T 1-0-25860 225860
X39 CONNECTION ELEMENT FOR M5 SCREW T&T 1-0-25860 225860
X40 CONNECTION ELEMENT FOR M5 SCREW T&T 1-0-25860 225860
X41 CONNECTION ELEMENT FOR M5 SCREW T&T 1-0-25860 225860
X42 TERMINAL BLOCK PCB VERS. 9 POLES 1.5mm2 WAGO 236-409 81.139
X43 TERMINAL BLOCK PCB VERS. 3 POLES 1.5mm2 WAGO 236-403 81.133
X44 CONNECTION ELEMENT FOR M5 SCREW T&T 1-0-25860 225860
X45 CONNECTION ELEMENT FOR M5 SCREW T&T 1-0-25860 225860

0448
PAGE 5-1
5 PARTSLIST CO4690

POSITION DESCRIPTION MANUFACTURER TYPE PART NO.

S1 ROCKER SWITCH SPST ON-OFF PCB VERSION, BLACK MARQUARDT 1801.2102 43.005
S2 SIL SQUARE PINS 3 POLES CC=1/10" AMP 0-826629-3 (0-826647-3) 78.323
S3 SIL SQUARE PINS 3 POLES CC=1/10" AMP 0-826629-3 (0-826647-3) 78.323
S4 SIL SQUARE PINS 2 POLES CC=1/10" AMP 0-826629-2 (0-826647-2) 78.322
S5 SIL SQUARE PINS 2 POLES CC=1/10" AMP 0-826629-2 (0-826647-2) 78.322
S6 SIL SQUARE PINS 2 POLES CC=1/10" AMP 0-826629-2 (0-826647-2) 78.322
S7 SIL SQUARE PINS 2 POLES CC=1/10" AMP 0-826629-2 (0-826647-2) 78.322
S8 SIL SQUARE PINS 2 POLES CC=1/10" AMP 0-826629-2 (0-826647-2) 78.322
S9 SIL SQUARE PINS 2 POLES CC=1/10" AMP 0-826629-2 (0-826647-2) 78.322
S10 ROCKER SWITCH SPST ON-OFF PCB VERSION, BLACK MARQUARDT 1801.2102 43.005
S11 SIL SQUARE PINS 3 POLES CC=1/10" AMP 0-826629-3 (0-826647-3) 78.323

9843
PAGE 5-2