CON012 - MCC 7000-Series Dispatch Console November 2012
CON012 - MCC 7000-Series Dispatch Console November 2012
DISPATCH CONSOLE
WORKSHOP
MODULE 4
Module 5 Module 6
Module 4
Conventional Domain
AUX I/Os
Communication Controllers
Module 7
Module 8
Administrator
Troubleshooting
Functions
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 2
Module 4 Learning Objectives
At the end of this module, you will be able to:
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 3
Module 4 Topics
• Topic 3-2: Auxiliary Inputs/Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 4
TOPIC 4-1
AUXILIARY
INPUTS/OUTPUTS
(AUX I/OS)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 5
Aux I/Os in the MCC 7000-Series
Dispatch Console Subsystem
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 6
Required Components
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 7
Console Site with Collocated Aux
I/O Server
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 8
Aux I/O Server – SDM 3000
• Required for Aux I/O
functionality.
• Supports up to 48 inputs and
16 outputs.
• Includes one RS232 serial port.
• Includes 16 electrically
energized Single Pole Single
Throw (SPST), Form A relay Aux I/O Server – Front View
outputs.
• Includes 48 discrete "Wet" or
"Dry" discrete inputs.
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 9
Aux I/O Server – SDM 3000 (contd.)
• Includes one
RS232/RS485
selectable serial port.
• Includes one I/O
communications port.
• Includes one console
port.
• Includes LAN Port 1, Aux I/O Server – Rear View
Ethernet 10/100 Base-T
port.
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 10
Aux I/O Server – SDM 3000 (contd.)
• Server Capacities
• I/O Shelf (external relays and/or inverters)
• SDM 3000 I/O Expansion Unit
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 11
Aux I/O Server Configuration
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 12
Software - Aux I/O Manager
• Is a software process running in the background on the MCC 7000-
Series Console.
• Maintains the links to the Aux I/O Servers.
• Searches in its database for the SDM 3000.
• Reports to the Dispatch Console about the input/output status.
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 13
Configuration Data
• Controlled or monitored at the MCC 7000-Series Console.
• Configured using Provisioning Manager.
• Data is stored in the User Database.
• Data is uploaded to the console and kept synchronized.
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 14
Configurations Supported
• Momentary Output
• Latched Output
• Interlocked Latched Output
• Momentary Input
• Latched Input
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 15
Aux I/O Servers Per Site
• Transport and Bandwidth Capacities
• Dispatch Console Site = 5
• RF Site = 7
• Simulcast Prime Site = 7
• Simulcast Remote Site = 3
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 16
Installing the Aux I/O Server and I/O
Expansion Units
• Rack-mounted SDM 3000 (1 rack unit, 1.75 inches high)
• Wire the back panel connections
• Set the jumper connections
• Connect the Dispatch Console PC to the Aux I/O Server
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 17
Installing the Aux I/O Server and I/O
Expansion Units (contd.)
• Configure the IP Address of the Aux I/O Server.
• Install and connect the SDM 3000 I/O Expansion Unit (if needed).
• Verify the operability of the connections.
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 18
Back Panel Wire Connections for
the SDM 3000
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 19
Setting Jumper Connections on the
SDM 3000 for Wet/Dry Digital Inputs
• Wet Digital Input: To set jumpers as DRY
for wet digital inputs,
• Power or voltage is being
insert the jumpers into
generated by the device .
the DRY position
• Needs a DRY jumper
connection at the SDM
3000.
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 20
Setting Jumper Connections on the SDM
3000 for Wet/Dry Digital Inputs (contd.)
Dry Digital Input: To set jumpers as WET for dry
digital inputs, insert the
• Power or voltage is not jumpers into the WET
being generated by the position.
device
• Needs a WET jumper Insert the jumper to select
connection at the SDM 12V or 24V option (WET/DRY
jumpers in WET)
3000
If 24V was selected, select the
Source/Sink 24V polarity
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 21
Setting Jumper Connections on the SDM
3000 for Wet/Dry Digital Inputs (contd.)
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 22
Mounting the SDM 3000 I/O
Expansion Unit
• Requires 1 rack-unit 1.75" high.
• Mounting brackets allow flexible mounting options.
• Mounted close to the SDM 3000.
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 23
Back Panel Wire Connections for
the SDM 3000 Expansion Unit
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 24
LAB
Lab Activity 3
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 25
Configuration
• Configure the SDM 3000.
• Configure the Aux I/O Servers.
• Create and configure the Interlock Groups.
• Configure the Aux I/Os.
• Configure the Comparator Aux I/Os.
MCC 7500 Dispatch Console with VPM - Chapter 10: Dispatch Console Auxiliary Inputs
and Outputs (Aux I/Os)
CON012 - MCC 7000-Series Dispatch Console 4: MCC 7000 Series Auxiliary I/Os
November 2012 26
MODULE 4 SUMMARY
You should now be able to:
MOTOROLA, MOTO, MOTOROLA SOLUTIONS and the Stylized M Logo are trademarks or registered trademarks of Motorola
Trademark
CON012 -Holdings, LLC andDispatch
MCC 7000-Series are used under license. All other trademarks are the property of their respective
Console owners.
4: MCC 7000 Series Auxiliary I/Os
© November
2012 Motorola