Rating 0.5 Amp to 125 Amps 1 Pole to 4 Pole Full Range tested for 10000 Amps Isolators upto 125 Amps AC22A Lighting & inductive load series B & C Designed for utmost safety Conforms to IS & IEC specs.
LINE
NOIDA UP 0607
Mfd. By
W E
C O N N E C T
F O R
L I F E
Vision
Delton Cables Ltd. is an ISO 9001: 2000 certified company committed to Quality and Customer Satisfaction. Delton provides competence in Cable technology covering measurement, control, communication and power distribution applications for different environmental conditions, as used in exploration, metal, oil, refining or gas processing sites, petrochemical, chemical, power generation and similar applications. Our specialization is in manufacturing tailor made cables as per customers specifications. Established in the year 1948 with a foresighted vision, a pioneering spirit, innovative approach, indigenously developed technology, the expertise of a highly motivated and professional team, excellent infrastructure facilities and sales network together synergised for the ultimate expression of customer delight, quality and safety.
W E
C O N N E C T
F O R
L I F E
W E
C O N N E C T
F O R
L I F E
Tripping Characteristic
Technical Information
Rating Voltage Rating No. of Poles Breaking Capacity Characteristics curves : : : : : 0.5 to 125 Amps 240/415V AC & DC 1P ,1P+N,2P ,3P+N,4P ,3P 10000 Amps (10KA) B & C Curve # D on Request
MCB
Standard Conformity Type/Series Rated Current (In) Rated Voltage (ac) (Ue) Rated Frequency Nos. of Poles (Execution) Rated Short Circuit Breaking Capacity kA Utilization Category Magnetic Release Setting Rated Insulation Voltage (Ui) Rated Impulse Voltage (Uimp) Electrical / Mechanical Endurance (Min. no. of operations) Ambient Temperature Terminal Capacity (max) Vibration Shock Protection Class Installation Position Mounting Case & Cover (oC) sq.mm g 30,000 -5 to +55 25 3 40mm free fall 30,000 -5 to +55 25 3 40mm free fall 30,000 -5 to +55 25 3 40mm free fall IP-20 Vertical / Horizontal Clip on DIN Rail (35mm) V kV 10 M10 (3-5)In 660 4 A V Hz 240/415 50 / 60 B IS 8828: 96 & IEC 898-1995 C 0.5 - 63 & 80-125 240/415 50 / 60 10 M10 (5-10)In 660 4 240/415 10 M10 (10-20)In 660 4 D#
ISOLATOR
IS 13947-3: 93 & IEC 60947-3: 2001 40 - 63 & 80-125 240/415 50 / 60 1P 2P 3P 4P , , , AC 22A 660 4 30,000 -5 to +55 25 5 40mm free fall
1P 1P+N, 2P 3P 3P+N, 4P , , ,
LOAD
NOIDA UP 0607
Mfd. By
LOAD
LINE
63 A
415V~
ISOLATO
In a current limiting breaker, the tripping mechanism & arc control is so designed that under short circuit conditions, the contacts are physically separated and
Voltage
the electrodynamic forces set up by fault current assist the extinction in less than half cycle.
TIME
The figure shows the current limiting effect of a circuit breakers. Fault Traces for Voltage & Current 0 = = = = Point of fault initiation Contact opening time (i.e., beginning of arc) Current / Voltage peak (i.e., limitation of current) Arc extinction time
Current
A Cut-off Current B cut off current Fault Current (Max. Prop.) t2 TIME
tx t1 t2
tx
t1
LINE
NOIDA UP 0607
Mfd. By
W E
C O N N E C T
F O R
L I F E
Magnetic Tripping Tripping current I2 1.45 x In Time t =1hr <1hr =1hr 1.45 x In <1hr =1hr 1.45 x In <1hr 10xIn 20 x In 5xIn 10 x In Hold I4 3xIn 5 x In Trip current I5 Time Limits t =0.1s <0.1s =0.1s <0.1s =0.1s <0.1s Limits current
120 60 30
min
10000 5000
1000 500
10 5 2 1 tv[s]
C Curve D Curve
B Curve
100 5
1 0.5 0.1
C Curve D Curve
Tripping Characteristics
Based on the Tripping Characteristics, MCBs are available in B, C and D curve to suit different types of applications. B Curve: for protection of electrical circuits with equipment that does not cause surge current (lighting and distribution circuits) Short circuit release is set to (3 - 5) In
0.01
C Curve: for protection of electrical circuits with equipment that causes surge current (inductive loads and motor circuits) Short circuit release is set to (5 - 10) In D Curve: for protection of electrical circuits which causes high inrush current, typically 12-15 times the thermal rated current (transformers, X-ray machines etc.) Short circuit release is set to (10 - 20) In
103 9 6 125A 4
160A
32A
1.5 1.4
0.9
Let through l t
40A/63A
1.3
Factor
3
2
0.8
4A 35A 2A 25A
40-63A
0.7
4 3
16-32A 6A 10A
0.6 1 2 3 4 5 6 7 8 9 10 11
2 1.5 10 2 4x10 5
3
-25 Graph 1
-10 0
10
20
30
40
0
50
60
10
1.5
8 10
1.5
Amb. Temp. ( C)
= = = = =
K1 x K2 x In 10A, and the amb. temp. is 50oC kept with no gap in between 0.89 (from graph 1) 0.78 (from graph 2) 0.89 x 0.78 x 10=6.94 A
W E
C O N N E C T
F O R
L I F E
Selection Chart The power loss value declared are at rated current.
Type of MCB "C" series "C" series "C" series "C" series "C" series "B" series "B" series "B" series "B" series "B" series B series "C" series "C" series "B" series "B" series "B" series "B" series "B" series "B" series "B" series "B" series 63 80 100 125 13.0 Under Consideration Under Consideration Under Consideration 7.2 Under Consideration Under Consideration Under Consideration Rated Current Amp. 10A 16A 20A 3A 4A 32A 10A 6A 10A 6A 10A 2A 8A 6A 10A 16A 32A 6A 8A 8A 10A 1 2 4 6 8 10 13 16 20 Max. allowable Watt loss per pole as per IS : 8828-1996, IEC 898-95 3 3 3 3.0 3.0 3.0 3.5 3.5 4.5 4.5 6.0 7.5 9.0 Delton MCB Max. Watt Loss per pole 1.3 1.5 2.2 0.7 0.9 1.3 1.6 2.1 2.3 3.0 3.3 3.5 6.0
25 32 40 50
Number of Lamps
Dimension
W E
C O N N E C T
F O R
L I F E
5.0
35.5 44.8
81.7
450 65.0
17.5
17.5 35
17.5 52.5
17.5 70
SP
SP-N/DP
TP
TP-N/FP
35.7
45.0 98.0
65.0
17.5
17.5 35
17.5 52.5
17.5 70
SP
SP-N/DP
TP
TP-N/FP
W E
C O N N E C T
F O R
L I F E
Product Range
LOAD
LOAD
NOIDA UP 0607
LINE
NOIDA UP 0607
Mfd. By
Mfd. By
LINE
415V~ 10000 3
63 A
415V~
1 2
5
O
C-40
415V~ 10000 3
ISOLATOR
1 3 5 7 2 4 6 8 FP
4 6 TP
LOAD
NOIDA UP 0607
LOAD
NOIDA UP 0607
LINE
NOIDA UP 0607
Mfd. By
C-40
LOAD
Mfd. By
Mfd. By
LOAD
NOIDA UP 0607
Mfd. By
LINE
LINE
C-40
O
415V~ 10000 3
1 2
C-40
5
O
415V~ 10000 3
1 3 5 7 2 4 6 8 FP
4 6 TP
63 A
415V~
ISOLATOR
LOAD
NOIDA UP 0607
LOAD
LINE
LOAD
NOIDA UP 0607
Mfd. By
63 A
415V~
LINE
ISOLATOR
1 3 5 7 2 4 6 8 FP
C-40
O
415V~ 10000 3
2 4 SP+N
An ISO 9001:2000 Certified Company Delton House, 4801, Bharat Ram Road, 24, Darya Ganj, New Delhi-110 002 Phones: 011-23273905-07 Fax: 011-23280375, 23272178 Email: dcl@deltoncables.com , dealer@deltoncables.com Web Site: www.deltoncables.com
Branch Offices - MUMBAI : 022-24936501 KOLKATA : 033-22824388 CHENNAI : 044-28587702 BANGALORE : 080-22263934 HYDERABAD : 09392430680 Representative - Bhubaneswar - 09437961873, Chandigarh - 09872074555, Guwahati - 09864060319, Jaipur - 09414047818, Lucknow - 09415578950, Rourkela - 09437962725
LINE
NOIDA UP 0607
Mfd. By
Mfd. By
LINE
NOIDA UP 0607
LOAD
Mfd. By
LINE