1 Function
This subrack has 17 positions for plug-in units and can be equipped with the necessary
units to build 6 complete first order multiplexer system.
This variant is the non-EMC version of the subrack and can be used with board variants
without EMC frontplates (except the QEXA card), but equipped with stiffeners instead.
2 Front view
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Q2LTS Manage
Alarm Lamp driver ment bus
DOCC: *NA
MMCC: *NA
20031010
Remarks :
if the CNCC (in position 16) is not equipped, a redundant ringer/power unit can be
mounted in this position.
in case of channel drop and insert, a slave PCM controller unit can be mounted in any
position if it is addressable by the CNCC : refer to Setting of system addresses.
an integrated line test unit ILTAUS can be mounted in any position if it is addressable
by the CNCC : refer to Setting of system addresses.
auxiliary units, if required, can be placed on any of the remaining places.
if no power distribution (POWER) is foreseen AC/DC convertors can be used
In case 1511BA with clock protection a slave PCM controller unit can be mounted:
in position 14 for multiplexer 1
in position 11 or 12 for multiplexer 2
in position 7 for multiplexer 3
in position 5 for multiplexer 4
in position 3 for multiplexer 5
in position 1 for multiplexer 6
Test
2 connectors for the through-connection between subracks of the test bus (daisy-chain
principle) :
01 : Not connected
06 : Not connected
02 : SL3 : Signal 3
07 : Not connected
03 : SL4 : Signal 4
08 : Not connected
04 : Not connected
09 : Not connected
05 : Not connected
Meaning :
TPCM system : Signal 3 - 4 : not connected
SPCM system :
Signal 3 : TBA : test bus A-wire
Signal 4 : TBB : test bus B-wire
LMP
This connector can be used with the cable 3AL 42877 AAAA to connect the lamps on top of
the rack.
Q2
Q2 interface connector (only if a CNCC is provided in position 16) :
08 : Not connected
15 : Not connected
07 : Not connected
14 : Not connected
06 : Clock in (+)
13 : Clock in (-)
05 : Not connected
12 : Electrical ground
04 : Data out (+)
11 : Data out (-)
03 : Not connected
10 : Electrical ground
02 : Data in (+)
09 : Data in (-)
01 : Safety ground
POWER
Power supply connector, connected to the power distribution via a connection cable 3AL
42732.
B B B
A A A
T T T
2 R 1
5 Power unit
The power unit is used to :
interrupt the power supply (BAT1 and BAT2) either manually or automatically in case of
overcurrent.
protect the boards in this subrack from transients and surges on the battery power
supplies.
Current rating : 5 A
Maximum resistance : 30 mΩ
Nominal voltage rating : 72 VDC
Short circuit breaking capacity : 1000 A at 72 VDC
Isolation resistance : 100 MΩ at 500 VDC
Dielectric strenght : 2kV AC
Note The addresses can also be set by means of switches on the backpanel of the
subrack : however, this method can only be used on the following conditions :
the CNCC is mounted on the subrack;
there is no need to extend the Q1 bus to other subracks;
the other functionalities of the QEXA unit (access for synchronization clock
input or output, access for auxiliary alarm inputs) are not required.
If the address setting is realized by means of the switches on the QEXA unit, all
ATTENTION switches on the backpanel of the subrack have to be open.
F X264
A
X266
Master Slave
E S678
S301 S401
D 1 1
2 2
3 3
4 4
5 5
GND 6 6
7 7
Open OUT IN 8 8
S246 ON S402ON
S7001 75Ω 120Ω 120 75Ω S302
S268 Ω
1 1
S286 S262 3
2 2
3
4 4 B
S285 ON ON
C S222 S524
S510
S221 64K 1200
Take care to select different groups by means of the switches of S301 and
ATTENTION S302.
As the switches of S302 can only select addresses below 32, it can be
appropriate to select the addresses above 32 with the switches of S301.
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
the 1st address belongs to the PCM controller unit in position 15 (1th multiplexer :
master) and the main ringer power unit RGPA in position 9;
the 2nd address belongs to the unit in position 13 (2th multiplexer : master) and the
redundant ringer power unit RGPA in position 10 or 16, if provided;
the 3rd address belongs to the unit in position 8 (3th multiplexer : master);
the 4th address belongs to the unit in position 6 (4th multiplexer : master);
the 5th address belongs to the unit in position 4 (5th multiplexer : master);
the 6th address belongs to the unit in position 2 (6th multiplexer : master);
the 7th address belongs to the unit in position 14;
the 8th address belongs to the unit in position 12.
The unit in position 1, 3, 5, 7, 10 to 12 and 14 can be a Slave PCM controller or TRIB.
Take care to select different groups by means of the switches of S301 and
ATTENTION S302.
As the switches of S302 can only select addresses below 32, it can be
appropriate to select the addresses above 32 with the switches of S301
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
address 1 belongs to the PCM controller unit in position 15 (1st multiplexer : master)
and the main ringer power unit RGPA in position 9;
address 2 belongs to the unit in position 13 (2nd multiplexer : master) and the
redundant ringer power unit RGPA in position 10 or 16, if provided;
address 3 belongs to the unit in position 8 (3th multiplexer : master);
address 4 belongs to the unit in position 6 (4th multiplexer : master);
address 5 belongs to the unit in position 4 (5th multiplexer : master);
address 6 belongs to the unit in position 2( 6th multiplexer : master);
address 7 belongs to the unit in position 14;
address 8 belongs to the unit in position 12;
address 9 belongs to the unit in position 7;
address 10 belongs to the unit in position 5;
address 11 belongs to the unit in position 3;
address 12 belongs to the unit in position 1;
address 13 belongs to the unit in position 11;
address 14 belongs to the unit in position 10;
address 15 belongs to the unit in position 9;
address 16 is not used.
The unit in position 1, 3, 5, 7, 10 to 12 and 14 can be a Slave PCM controller or TRIB.
S700
CNCC PWR
OFF ON
1
2
S701 3
4
OFF ON
If the address setting is realized on 1
2
the QEXA unit, these switches have S702
3
4
to be open (as shown) !! 5
6
7
8