1 Function
This subrack has 17 positions for plug-in units and can be equipped with the necessary
units to build 6 complete first order multiplexer system. It is power-fed from the AC mains
by means of an AC/DC converter.
2 Front view
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Q2LTS Manage
Alarm Output
Alarm Lamp driver ment bus
connector
Cable to Cable to
Control connector
next subrack previous subrack
Test bus extension (option) Battery connector
3 Subrack equipment
The subrack is equipped as follows :
DOCC: *NA
MMCC: *NA
20031010
Remarks :
in case of channel drop and insert, a slave PCM controller unit can be mounted in any
position if it is addressable by the CNCC : refer to Setting of system addresses.
an integrated line test unit ILTAUS can be mounted in any position if it is addressable
by the CNCC : refer to Setting of system addresses.
auxiliary units, if required, can be placed on any of the remaining places.
In case 1511BA with clock protection a slave PCM controller unit can be mounted:
in position 14 for multiplexer 1
in position 11 or 12 for multiplexer 2
in position 7 for multiplexer 3
in position 5 for multiplexer 4
in position 3 for multiplexer 5
in position 1 for multiplexer 6
Test
2 connectors for the through-connection between subracks of the test bus (daisy-chain
principle) :
01 : Not connected
06 : Not connected
02 : SL3 : Signal 3
07 : Not connected
03 : SL4 : Signal 4
08 : Not connected
04 : Not connected
09 : Not connected
05 : Not connected
Meaning :
TPCM system : Signal 3 - 4 : not connected
SPCM system :
Signal 3 : TBA : test bus A-wire
Signal 4 : TBB : test bus B-wire
LMP
This connector can be used with the cable 3AL 42877 AAAA to connect the lamps on top of
the rack.
Q2
Q2 interface connector (only if a CNCC is provided in position 16) :
08 : Not connected
15 : Not connected
07 : Not connected
14 : Not connected
06 : Clock in (+)
13 : Clock in (-)
05 : Not connected
12 : Electrical ground
04 : Data out (+)
11 : Data out (-)
03 : Not connected
10 : Electrical ground
02 : Data in (+)
09 : Data in (-)
01 : Safety ground
Q2 interface of CNCC (if provided on the subrack) : can be connected to the top block via
a cable 3AL 42734
BAT
Power connection to battery
CONTR
Control connector
05 : Not connected
09 : Not connected
04 : Not connected
08 : Not connected
03 : SHUNT +
07 : Not connected
02 : SHUNT -
06 : Not connected
01 : Not connected
ALARM
For connection to End of Discharge (EOD) unit (switch between battery charging and
subrack fed by battery).
01 : EODAL
06 : EODRES +
02 : FUSEAL
07 : EODRES -
03 : Not connected
08 : Not connected
04 : COMMON
09 : Not connected
05 : Not connected
Note After connecting the battery to the subrack, the subrack has to be reset by
looping 'EODRES+' to 'EODRES -'in order to activate the battery feed.
CLK 123
F X264
A
X266
Master Slave
E S678
S301 S401
D 1 1
2 2
3 3
4 4
5 5
GND 6 6
7 7
Open OUT IN 8 8
S246 ON S402ON
S7001 75Ω 120Ω 120 75Ω S302
S268 Ω
1 1
S286 S262 3
2 2
3
4 4 B
S285 ON ON
C S222 S524
S510
S221 64K 1200
Note The addresses can also be set by means of switches on the backpanel of the
subrack : however, this method can only be used on the following conditions :
the CNCC is mounted on the subrack;
there is no need to extend the Q1 bus to other subracks;
the other functionalities of the QEXA unit (access for synchronization clock
input or output, access for auxiliary alarm inputs) are not required.
If the address setting is realized by means of the switches on the QEXA unit, all
ATTENTION switches on the backpanel of the subrack have to be open.
Normal exploitation
4 consecutive numbers (within the same group of 8) are assigned to the subrack. Selection
is achieved by setting 5 switches in the ON position :
one switch of S301 is set to ON to select a group of 8 addresses (the other switches of
S301 and all switches of S302 are set to OFF);
the first 4 switches of S401 are set to ON if the first 4 addresses of the group have to
be used (the other switches of S401 and all switches of S402 are set to OFF);
the 4 switches of S402 are set to ON if the last 4 addresses of the group have to be
used (all switches of S401 are set to OFF).
Example : system addresses 17 to 20
Value Value
0 1 1 1
8 2 2 2
16 3 3 3
24 4 4 4
S301 32 5
S401
5 5
40 6 6 6
48 7 7 7
56 8 8 8
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7
S402
16 4 4 8
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
Take care to select different groups by means of the switches of S301 and
ATTENTION S302.
As the switches of S302 can only select addresses below 32, it can be
TIP appropriate to select the addresses above 32 with the switches of S301.
Value Value
8 1 1 5
24 2 2 6
S302 0 3 3 7 S402
16 4 4 8
the 1st address belongs to the PCM controller unit in position 15 (1st multiplexer :
master) and the main AC/DC converter in position 7/8;
the 2nd address belongs to the unit in position 13 (2nd multiplexer : master) and the
redundant AC/DC converter in position 11/12, if provided;
address 3 belongs to the unit in position 8 (3th multiplexer : master);
address 4 belongs to the unit in position 6 (4th multiplexer : master);
address 5 belongs to the unit in position 4 (5th multiplexer : master);
address 6 belongs to the unit in position 2( 6th multiplexer : master);
address 7 belongs to the unit in position 14;
address 8 belongs to the unit in position 12;
address 9 belongs to the unit in position 7;
address 10 belongs to the unit in position 5;
address 11 belongs to the unit in position 3;
address 12 belongs to the unit in position 1;
address 13 belongs to the unit in position 11;
address 14 belongs to the unit in position 10;
address 15 belongs to the unit in position 9;
address 16 is not used.
The unit in position 1, 3, 5, 7, 10 to 12 and 14 can be a Slave PCM controller or TRIB.
S700
CNCC PWR
S701
1
2
3
4
S702 ON
If the address setting is realized on
1
2
3
the QEXA unit, these switches have 4
5
6
to be open (as shown) !! 7
8
ON