1 Function
This unit converts the 115 V AC mains voltage to the 48 V DC battery voltage. Part of the
output power is intended for floating and charging a battery which provides for the power
in case of mains failure.
This board is intended to be used in combination with an RPGA board (3AL 43050). The
AC/DC convertor will provide the -48 V on the backpanel. The RPGA board will provide
the +5 V and the -5 V power supplies and the ringing current.
If ringing current is not required, then the RPGA board is not required if an
NOTICE AC/DC converter 3AL 42929 is being used. This board will then provide the +5
V and the -5 V power supplies.
2 Output Voltage
The value of the -48V output voltage can be controlled as a function of the ambient
temperature of the battery in order to meet the voltage/temperature characteristic of the
battery (shown below).
Floating voltage (Volt)
58
57
56
55
54
53
52
51
50
–30–20–10 0 10 20 30 40 50 60
3 Application
This variant is intended to be used with the following subracks:
DOCC: *NA
MMCC: *NA
20020909
4 End of Discharge
To prevent battery damage, an EOD unit (End Of Discharge) unit is mounted to switch
between battery charging and subrack fed by battery.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
RGPA–R
AC/DC
RGPA Type B
sensing
Temperature
Mains ~
Battery Access
Connector
Charge/backup
switch
EOD
I–sense
Backup/charge control
EOD = End of Discharge
Backup battery
This EOD unit drives a switch that shall be equipped in a separate module in between the
battery and the system in order to switch off the battery from the load in case of
overdischarge of the battery at a mains failure. The control for switching off this end of
discharge switch shall be done inside the converter, giving the appropriate signal to the
switchmodule via a front connector.
AC / DC CONVERTER
3 2 1 5
RELAY DRIVE +
RELAY DRIVE –
SHUNT +
SHUNT –
NTC1
NTC2
3 2 1 5
–t 2K7
1AB 05513 0001
Philips code : 2322 640 98015
2x100mohm
Be sure never to interrupt the safety ground when the AC/DC converter is
connected to the AC mains source.
Before removing the AC/DC converter from the subrack, interrupt the AC mains
voltage and wait for at least 4 minutes to allow the discharging of the internal
WARNING capacitors before handling the unit.
All adjustments, replacements, repairs,... should be carried out by a qualified
person, aware of the hazards involved, with the converter completely
disconnected from the AC power source.
5 Front view
AL AC
T SENSE
CONTROL
ALWAYS DISCONNECT
THE SUPPLY BEFORE
SERVICING
NO USER SERVICEABLE
PARTS INSIDE
MAINS
AC : 115V / 3A / 47–63Hz
BEFORE USE
SEE INSTRUCTIONS
6 Operational data
AC mains input:
input voltage:
nominal: 115 V
minimum: 85 V
maximum: 132 V
input frequency: 47 to 63 Hz
the converter is switched off in case of input undervoltage
DC output:
output voltage: -48V + 10 V
maximum load: 3 A
overcurrent protection (current limiting): between 3,15 and 3,75 A
overvoltage protection (converter switched off): -59 V maximum
undervoltage alarm: between -33 and -37 V
efficiency: 83 % at maximum load
parallel operation of the converters is possible (output via separation diodes)
End of discharge protection:
V battery switch-off:
V minimum: -42 V
V maximum: -44 V
An alarm signal is generated in the following cases:
input undervoltage (the converter is switched off)
output overvoltage (the converter is switched off)
output undervoltage (the converter is not switched off)
7 Front indications
AC: green LED, indicating the normal functioning of the unit;
AL: red LED, indicating an alarm situation on the unit.
T SENSE NTC2
MAINS
AC : 115V / 3A / 47–63Hz
BEFORE USE
SEE INSTRUCTIONS
8/8
None
ABXX
3AL 42930
Strap options
AC/DC converter