AC/DC converter 3AL 42930

ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

1 Function
This unit converts the 115 V AC mains voltage to the 48 V DC battery voltage. Part of the
output power is intended for floating and charging a battery which provides for the power
in case of mains failure.
This board is intended to be used in combination with an RPGA board (3AL 43050). The
AC/DC convertor will provide the -48 V on the backpanel. The RPGA board will provide
the +5 V and the -5 V power supplies and the ringing current.

If ringing current is not required, then the RPGA board is not required if an
NOTICE AC/DC converter 3AL 42929 is being used. This board will then provide the +5
V and the -5 V power supplies.

2 Output Voltage
The value of the -48V output voltage can be controlled as a function of the ambient
temperature of the battery in order to meet the voltage/temperature characteristic of the
battery (shown below).
Floating voltage (Volt)

58
57
56
55
54
53
52
51
50
–30–20–10 0 10 20 30 40 50 60

Battery ambient temperature (ºC)

3 Application
This variant is intended to be used with the following subracks:

DOCC: *NA
MMCC: *NA
20020909

3AL 42930 ABAA TNAAA Edition 03 1/8


3AL 42930 AC/DC converter
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
 3AL 42912 BCAA (17 pos.  3 MUX)
 3AL 42914 ACAA (17 pos.  2 MUX)
 3AL 42923 ACAA (17 pos.  1 MUX).

4 End of Discharge
To prevent battery damage, an EOD unit (End Of Discharge) unit is mounted to switch
between battery charging and subrack fed by battery.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

RGPA–R
AC/DC
RGPA Type B
sensing
Temperature

Mains ~
Battery Access
Connector
Charge/backup
switch
EOD

I–sense

Backup/charge control
EOD = End of Discharge
Backup battery

This EOD unit drives a switch that shall be equipped in a separate module in between the
battery and the system in order to switch off the battery from the load in case of
overdischarge of the battery at a mains failure. The control for switching off this end of
discharge switch shall be done inside the converter, giving the appropriate signal to the
switchmodule via a front connector.

2/8 3AL 42930 ABAA TNAAA Edition 03


AC/DC converter 3AL 42930
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

AC / DC CONVERTER

3 2 1 5

RELAY DRIVE +

RELAY DRIVE –
SHUNT +

SHUNT –

NTC1

NTC2
3 2 1 5

–t 2K7
1AB 05513 0001
Philips code : 2322 640 98015
2x100mohm

Battery Current Sense Battery Switch Battery Temperature Sense


EMA POWER FILTER UNIT

Be sure never to interrupt the safety ground when the AC/DC converter is
connected to the AC mains source.
Before removing the AC/DC converter from the subrack, interrupt the AC mains
voltage and wait for at least 4 minutes to allow the discharging of the internal
WARNING capacitors before handling the unit.
All adjustments, replacements, repairs,... should be carried out by a qualified
person, aware of the hazards involved, with the converter completely
disconnected from the AC power source.

3AL 42930 ABAA TNAAA Edition 03 3/8


3AL 42930 AC/DC converter
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
Each time a corrective action has been realized and the normal operation of
ATTENTION the AC/DC converter has to be verified, the converter has to be restarted by
switching off the AC mains or by removing the AC mains supply voltage for at
least 30 s and reactivating or reconnecting it.

5 Front view

AL AC

T SENSE

CONTROL

ALWAYS DISCONNECT
THE SUPPLY BEFORE
SERVICING

NO USER SERVICEABLE
PARTS INSIDE

CAUTION : DOUBLE POLE


NEUTRAL FUSING

MAINS

AC : 115V / 3A / 47–63Hz

BEFORE USE
SEE INSTRUCTIONS

4/8 3AL 42930 ABAA TNAAA Edition 03


AC/DC converter 3AL 42930
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

6 Operational data
AC mains input:
 input voltage:
 nominal: 115 V
 minimum: 85 V
 maximum: 132 V
 input frequency: 47 to 63 Hz
 the converter is switched off in case of input undervoltage
DC output:
 output voltage: -48V + 10 V
 maximum load: 3 A
 overcurrent protection (current limiting): between 3,15 and 3,75 A
 overvoltage protection (converter switched off): -59 V maximum
 undervoltage alarm: between -33 and -37 V
 efficiency: 83 % at maximum load
 parallel operation of the converters is possible (output via separation diodes)
End of discharge protection:
 V battery switch-off:
 V minimum: -42 V
 V maximum: -44 V
An alarm signal is generated in the following cases:
 input undervoltage (the converter is switched off)
 output overvoltage (the converter is switched off)
 output undervoltage (the converter is not switched off)

7 Front indications
 AC: green LED, indicating the normal functioning of the unit;
 AL: red LED, indicating an alarm situation on the unit.

3AL 42930 ABAA TNAAA Edition 03 5/8


3AL 42930 AC/DC converter
ABXX

not permitted without written authorization from Alcatel.


document, use and communication of its contents
All rights reserved. Passing on and copying of this
8 Front connectors

8.1 Front connectors overview


 AC mains input voltage connector. Connector type: IEC 320 male.
 Battery temperature sensor input. Connector type: AMP Universal MATENLOCK
male.
 Battery current sensor input and End of Discharge switch signal: SubD 9pins male

8.2 Front Connectors Lay out

6/8 3AL 42930 ABAA TNAAA Edition 03


AC/DC converter 3AL 42930
ABXX
not permitted without written authorization from Alcatel.
document, use and communication of its contents
All rights reserved. Passing on and copying of this

Battery temperature sensor input. Con


nector type: AMP Universal MATEN
AL AC
LOCK male.
NTC1

T SENSE NTC2

Battery current sensor input and End of


CONTROL Discharge switch signal: SubD 9pins
male
ALWAYS DISCONNECT
THE SUPPLY BEFORE 01 : Relay Drive +
SERVICING
06 : Not Used
02 : Shunt –
07 : Not Used
NO USER SERVICEABLE 03 : Shunt +
PARTS INSIDE 08 : Not Used
09 : Not Used 04 : Not Used
CAUTION : DOUBLE POLE 05 : Relay Drive –
NEUTRAL FUSING

MAINS

Regural Power Cord connector.

AC : 115V / 3A / 47–63Hz

BEFORE USE
SEE INSTRUCTIONS

3AL 42930 ABAA TNAAA Edition 03 7/8


9

8/8
None
ABXX
3AL 42930

Strap options
AC/DC converter

3AL 42930 ABAA TNAAA


Edition 03