Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

LEGEND:

6 WATTS PINLIGHT

9 WATTS PINLIGHT

SURFACE MOUNTED
CANOPY LIGHT
MECHANICAL ECT.) SHALL BE SUBJECT FOR VERIFICATION.

TRACK LIGHTS
ANY DISCREPANCY ON ALL DRAWINGS & SPECIFICATIONS
(ARCHITECTURAL, STRUCTURAL, SANITARY, ELECTRICAL,

WP WPO

ACU
RANGE
T5 COVE LIGHT
13
12 6
EMERGENCY LIGHT
S1
BEDROOM 02

ACU ACU CATV


KITCHEN
BEDROOM 02
KITCHEN 11 AIRCONDITION UNIT
9
CONVENIENCE OUTLET
S1 S1 ACU
BEDROOM 01
COMMON T&B REF
RANGE CONVENIENCE OUTLET
S2
COMMON T&B S2 7 RANGE
BEDROOM 01 MINI LIBRARY
REFRIGERATOR
S2

SERVICE AREA
CONVENIENCE OUTLET
REF

T&B WATER PUMP


CONVENIENCE OUTLET
UP WP
T&B S1 DINING AREA
WEATHERPROOF
DINING AREA MINI LIBRARY CONVENIENCE OUTLET
WPO

SINGLE CONVENIENCE OUTLET


ACU 10
NOTE:

STAIRWELL

8
DUPLEX CONVENIENCE OUTLET
S2 ACU
MASTER BEDROOM
TRIPLEX CONVENIENCE OUTLET
LIVING AREA 5

S1 1-GANG LIGHT SWITCH


1
STAIR HALLWAY
LIVING AREA
AND CONDITIONS ON THE JOB. THE DESIGNER MUST BE NOTIFIED IMMEDIATELY OF ANY

4
S2 S2 3
MASTER BEDROOM DOWN S2 2-GANG LIGHT SWITCH
WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALE

S2
VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS.
DIMENSIONS. CONTRACTORS SHALL VERIFY ND RESPONSIBLE FOR ALL DIMENSIONS

S2 2
WPO ENTRY PORCH
S3
WPO
BALCONY
S3 3-GANG LIGHT SWITCH
BALCONY
ENTRY PORCH
PANEL BOARD
MPB

# CIRCUIT HOMERUN

CARPORT
M METER

LIGHTING CIRCUIT LINE

CONVENIENCE CIRCUIT LINE

CARPORT
LIGHT SWITCH LINE

GROUND FLOOR SECOND FLOOR GROUND FLOOR SECOND FLOOR

E LIGHTING LAYOUT PLAN E POWER LAYOUT PLAN


12 S C A L E 1 : 1 0 0 M E T E R S 22 S C A L E 1 : 1 0 0 M E T E R S
NOTE:

SIGNED & SEALED: R.A. 9266, SEC. 33 (4): PROJECT TITLE: OWNER: SHEET CONTENTS: SHEET NO.:
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT
DOCUMENTS DULY SIGNED, STAMPED OR SEALED, AS A PROPOSED:
INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT
ALICIA R. ENCOMIO AS SHOWN E-1
FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE
UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE
TWO (2) - STOREY RESIDENTIAL BUILDING
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF
AND FOR OTHER PROJECTS OR BUILDINGS, WHETHER 14 18
EXECUTED PARTLY OR IN WHOLE, WITHOUT THE WRITTEN
CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS. LOCATION: BRGY. UTAP, TACLOBAN CITY, LEYTE, PHILIPPINES, 6500 ADDRESS: TACLOBAN CITY, LEYTE, PHILIPPINES, 6500 SCALE: AS SHOWN

You might also like