Professional Documents
Culture Documents
Cable Guide For All Portserver TS, Digi Connect, and Digi One Products
Cable Guide For All Portserver TS, Digi Connect, and Digi One Products
Cable Guide For All Portserver TS, Digi Connect, and Digi One Products
90000253_G
© Digi International Inc. 2013. Digi, Digi International, the Digi logo, Digi One,
Digi Connect, PortServer TS, and RealPort are trademarks or registered trademarks of
Digi International, Inc. in the United States and other countries. worldwide. All other
trademarks are the property of their respective owners.All other trademarks are the
property of their respective owners.
Information in this document is subject to change without notice and does not represent
a commitment on the part of Digi International.
Digi provides this document “as is,” without warranty of any kind, either expressed or
implied, including, but not limited to, the implied warranties of fitness or merchantability
for a particular purpose. Digi may make improvements and/or changes in this manual or
in the product(s) and/or the program(s) described in this manual at any time.
This product could include technical inaccuracies or typographical errors. Changes are
periodically made to the information herein; these changes may be incorporated in new
editions of the publication.
Ta b l e o f C o n t e n t s
Chapter 1 EIA-232 asynchronous interface
General EIA-232 cable information........................................................................................9
Physical cable characteristics ........................................................................................................ 9
Grounding requirements ................................................................................................................ 9
Environmental requirements .......................................................................................................... 9
Data rate information...................................................................................................................... 9
Data rate vs. cable length recommendations............................................................................... 10
Resolving transmission errors...................................................................................................... 10
Contents 3
RJ-45 8-pin crossover cable for Cisco and Sun Netra......................................................... 27
RJ-45 to RJ-45 8-pin crossover cable.......................................................................................... 27
Pin positions for RJ-45 ................................................................................................................. 27
4 Contents
Loopback connector pinouts ................................................................................................ 52
EtherLite RJ-45 to DB-25M modem adapter........................................................................ 53
EtherLite RJ-45 to DB-25M 4-Wire duplex cable (RS-422) ................................................. 54
EtherLite RJ-45 to DB-25M console adapter ....................................................................... 55
EtherLite RJ-45 to DB-9F console adapter .......................................................................... 56
EtherLite and SCSI Terminal Server RJ-45 to DB-9M modem cable .................................. 57
EtherLite and SCSI Terminal Server RJ-45 to DB-9F terminal emulator cable ................... 58
EtherLite and SCSI Terminal Server RJ-45 to DB-25M modem cable ................................ 59
EtherLite RJ-45 8-pin to DB-25M DTE modtap adapter ...................................................... 60
EtherLite RJ-45 8-pin to DB-25M DCE modtap adapter ...................................................... 61
EtherLite RJ-45 to DB-9F DCE modtap adapter.................................................................. 62
EtherLite and SCSI Terminal Server RJ-45 to RJ-45 Cisco console adapter...................... 63
EtherLite and SCSI Terminal Server RJ-45 to DB-25M terminal printer cable .................... 64
Digi One, PortServer TS, and Multi-Port Serial Cards RJ-45 to DB-9F cable adapter ........ 65
Digi One, PortServer TS, and Multi-Port Serial Cards RJ-45 to DB-25M console adapter.. 66
Digi One, PortServer TS, and Multi-Port Serial Cards RJ-45 to DB-25F cable adapter ...... 67
Digi One, PortServer TS, and Multi-Port Serial Cards RJ-45 to DB-25M modem adapter .. 68
Digi One, PortServer TS, and Multi-Port Serial Cards RJ-45 to DB-9M modem adapter .... 69
Digi One, PortServer TS, and Multi-Port Serial Cards RJ-45 to DB-25M printer adapter.... 70
Digi CM RJ-45 to DB-9F DTE RS-232 crossover cable.......................................................71
Digi CM RJ-45 to DB-25M modem adapter ......................................................................... 72
Digi CM RJ-45 to DB-9F console adapter............................................................................73
Digi CM RJ-45 to DB-25M console adapter......................................................................... 74
Digi CM RJ-45 to DB-25F console adapter.......................................................................... 75
Digi CM RJ-45 to DB-9M modem adapter ........................................................................... 76
Digi CM RJ-45 to DB-25M (DCE RS 232) straight-through cable........................................ 77
Digi CM EIA-232 RJ-45 to DB-25M (DTE RS 232) crossover cable.................................... 78
Digi CM RJ-45 to RJ-45 Sun Netra or Cisco crossover cable ............................................. 79
Digi CM RJ-45 to Sun Mini Din cable...................................................................................80
Async conversion RJ-XX to DB-XX ..................................................................................... 82
Cable vendors......................................................................................................................83
DataFire Sync 2000 SCSI pinouts ....................................................................................... 84
Digi One EM DB-9 connector pinouts .................................................................................. 85
Digi One IA RealPort EIA-232 DB-9 connector pinout......................................................... 86
Digi One EM EIA-232 DB-9 and terminal block pinout ........................................................ 87
Digi One SP DB-9 pinout ..................................................................................................... 88
Async EIA-422 DB-9 connector pinout ................................................................................ 89
Async EIA-422 DB-25 pinout ............................................................................................... 90
Async RJ-45 to RJ-45 crossover cable - for cross-connecting Digi asynchronous ports
together................................................................................................................................ 91
DB-25F to RJ-45 Cisco console cable adapter.................................................................... 92
SCSI Terminal Server DB-25M to RJ-45 Cisco console cable adapter ............................... 93
Contents 5
Difference between DTE and DCE ...................................................................................... 94
DB-9F to RJ-45 3COM Total Control/COMPAQ Microcom modem cable.......................... 95
SCSI Terminal Server DB-25M to RJ-45 3COM Total Control/COMPAQ Microcom modem
cable .................................................................................................................................... 96
DB-25F to RJ-45 3COM Total Control/COMPAQ Microcom modem cable......................... 97
RJ-45 to RJ-45 (Altpin on) 3 COM Total Control/COMPAQ Microcom modem cable ......... 98
RJ-45 10-pin to RJ-45 3 COM Total Control/Compaq Microcom modem cable .................. 99
DB-9F to DB-9M modem cable.......................................................................................... 100
DB-9F to DB-25M modem cable........................................................................................101
DB-25F to DB-9M modem cable........................................................................................102
DB-25F to DB-25M modem cable...................................................................................... 103
SCSI Terminal Server DB-25M to DB-9M modem cable ................................................... 104
RJ-45 (Altpin on) to DB-9M modem cable ......................................................................... 105
RJ-45 (Altpin on) to DB-25M modem cable ....................................................................... 106
RJ-45 10-pin to DB-9M modem cable................................................................................ 107
RJ-45 10-pin to DB-25M modem cable.............................................................................. 108
DB-9F to DB-9F terminal emulator cable........................................................................... 109
DB-9F to DB-25F terminal emulator cable......................................................................... 110
DB-25F to DB-9F terminal emulator cable......................................................................... 111
DB-25F to DB-25F terminal emulator cable....................................................................... 112
SCSI Terminal Server DB-25M to DB-9F terminal emulator cable .................................... 113
SCSI Terminal Server DB-25M to DB-25F terminal emulator cable .................................. 114
RJ-11 6-pin/4-wire to DB-9F terminal emulator cable........................................................ 115
RJ-11 6-pin/4-wire to DB-25F terminal emulator cable - software flow control only .......... 116
RJ-11 6-pin to DB-9F terminal emulator cable...................................................................117
RJ-11 6-pin to DB-25F PC terminal emulator cable........................................................... 118
RJ-45 4-wire to DB-9F terminal emulator cable - software flow control only ..................... 119
RJ-45 4-wire to DB-25F terminal emulator cable - software flow control only ................... 120
RJ-45 (Altpin on) to DB-9F terminal emulator cable .......................................................... 121
RJ-45 (Altpin on) to DB-25F terminal emulator cable ........................................................ 122
RJ-45 to DB-9F terminal emulator cable............................................................................ 123
RJ-45 10-pin to DB-9F terminal emulator cable................................................................. 124
RJ-45 10-pin to DB-25F terminal emulator cable............................................................... 125
RJ-45 (Altpin On) to RJ-45 Cisco console adapter ............................................................126
V.35 to DB-25M cabling ..................................................................................................... 127
V.35 pinout......................................................................................................................... 128
X.21 V.11 to DB-15 cable pinout........................................................................................129
Digi AccelePort Xp and NEO HD-68-pin Ultra SCSI connector ......................................... 130
Sync V.24 DB-25 connector pinout.................................................................................... 134
EIA 422 DB-25 pinouts for Sync boards ............................................................................ 135
Sync 2000 single-port V.36/EIA-449 pinout ....................................................................... 136
DB-9F to DB-9M terminal/printer cable.............................................................................. 137
6 Contents
DB-9F to DB-25M terminal/printer cable............................................................................ 138
DB-25F to DB-9M terminal/printer cable............................................................................ 139
DB-25F to DB-25M terminal/printer cable..........................................................................140
SCSI Terminal Server DB-25M to DB-9M terminal/printer cable .......................................141
SCSI Terminal Server DB-25M to DB-25M terminal/printer cable ..................................... 142
RJ-11 6-pin/4-wire to DB-9M terminal/printer cable........................................................... 143
RJ-11 6-pin/4-wire to DB-25M terminal/printer cable......................................................... 144
RJ-11 6-pin to DB-9F terminal/printer cable ...................................................................... 145
RJ-11 6-pin to DB-25M terminal/printer cable.................................................................... 146
RJ-45 4-wire to DB-9M terminal/printer cable - software flow control only ........................ 147
RJ-45 4-wire to DB-25M terminal/printer cable.................................................................. 148
RJ-45 (Altpin on) to DB-9M terminal/printer cable ............................................................. 149
RJ-45 to DB-25M terminal/printer cable............................................................................. 150
RJ-45 to DB-9M terminal/printer cable............................................................................... 151
RJ-45 10-pin to DB-9M terminal/printer cable.................................................................... 152
RJ-45 10-pin to DB-25M terminal/printer cable.................................................................. 153
Contents 7
Chapter 1 EIA-232 asynchronous interface
General EIA-232 cable information
Use this information to determine the proper EIA-232 cable requirements
for your application.
Physical cable characteristics
EIA-232 serial interface cables should be shielded, low capacitance cables,
designed specifically for serial data transmission.
Grounding requirements
EIA-232 interface cables should have the shield grounded at both ends of
the cable. Digi recommends Chassis Ground, available on the shell of
Digi's DB-25 connectors, and pin 4 of a 10-pin RJ-45 connector.
Environmental requirements
While good shielding provides reasonable protection against “noise”
(electromagnetic interference, or EMI), cables should still be routed away
from noise sources wherever possible. Avoid laying cables in close
proximity to transformers, generators, motors, fluorescent lights, etc.
Data rate information
The maximum data rate that can be used for EIA-232 connections is
primarily determined by the quality and length of the interconnecting cable.
The quality of the cable (for transmission purposes) is generally
determined by the capacitance per foot rating of the cable.
The following table gives the recommended maximum cable length for a
given data rate. Longer cables may be implemented at your discretion.
Note that not all Digi products support all of the data rates listed below.
115,200 80 feet
230,400 40 feet
460,800 20 feet
921,600 10 feet
This cable is a three-wire null modem cable. Transmitted data on one end
of the cable is connected to received data at the other end, and vice versa.
The male DB-25 end can be plugged directly into most serial terminals and
printers without any adapters. The female DB-25 end plugs directly into
any Digi DB-25 serial port.
SG 7 connected to 7 SG
Note: Some terminal or printer manufacturers may use different methods of flow
control. Consult your documentation for specific wiring requirements.
SG 7 connected to 7 SG
Note: Some terminal or printer manufacturers may use different methods of flow
control. Consult your documentation for specific wiring requirements.
Note: Some terminal or printer manufacturers may use different methods of flow
control. Consult your documentation for specific wiring requirements.
76000631 (6’)
For use with Cisco and Sun Cable 76000632 (qty 8) 63000222-02
RJ45 M * Special *
RJ45 Console ports. 76000633 (qty 16)
Adapter None NA
1 RI 1
DSR (DCD*)
2 2 1
*When ALTPIN is in effect.
3 RTS 3 2 1
4 GND 4 3 2 1
5 TxD 5 4 3 2
6 RxD 6 5 4 3
7 SG 7 6 5 4
8 CTS 8 7 6
9 DTR 9 8
DCD (DSR*)
10 10
*When ALTPIN is in effect.
Number
Cable description Order # found on
cable
Number
Cable description Order # found on
cable
Number
Cable Description Order # found on
cable
RJ-11
DB-25 male (peripheral)
(Digi end)
SG 4 connected to 7 SG
This cable is a 3-wire null modem cable. Transmitted data on one end of
the cable is connected to received data at the other end and vice-versa.
The RJ-11 plug fits into the center of the RJ-45 jack. The male DB-25 end
can be plugged directly into most serial terminals and printers without any
adapters.
An RJ-45 8-pin connector uses the same wiring with the center pins only-
pins 3, 4, 5, and 6. See "RJ connector types" on page 18 for a comparison
of various RJ connector types that work with the Digi 10-pin RJ-45 jack.
RJ-45
DB-25 male (peripheral)
(Digi end)
SG 6 connected to 7 SG
Note: Some terminal or printer manufacturers may use different methods of flow
control. Consult your documentation for specific wiring requirements.
SG 6 connected to 7 SG
Note: Some terminal or printer manufacturers may use different methods of flow
control. Consult your documentation for specific wiring requirements.
DCD*
* ALTPIN must be turned on for pin 1 to be
DCD. When ALTPIN is enabled, DCD 1 connected to 20 DTR
becomes available on pin 1 of an 8-pin RJ-
45 connector (equivalent to pin 2 of a 10-pin
connector).
SG 6 connected to 7 SG
Note: Some terminal or printer manufacturers may use different methods of flow
control. Consult your documentation for specific wiring requirements.
DSR+DCD*
* ALTPIN must be turned 2+10 connected to 20 DTR
off for DCD to be on pin
10
SG 7 connected to 7 SG
DSR+D
DTR 9 connected to 6+8
CD
Note: Some terminal or printer manufacturers may use different methods of flow
control. Consult your documentation for specific wiring requirements.
SG 6 connected to 7 SG
RI 1 connected to 22 RI
SG 7 connected to 7 SG
to Cisco/SunNetra
from RJ-45 port Signal Signal
RJ-45 port
The following table shows the pin configurations for the EIA-422 versions
of Digi DB-9, DB-25, and RJ-45 connectors.
Optional
RJ-45 RJ-45
Signal Description DB-9 pin DB-25 pin
10-pin 8-pin
(2 wire)
SG Signal Ground - - 7 6
- Connected to -
RxD + Connected to + TxD
- Connected to -
GND Connected to - GND
CTS CTS
- Connected to -
RxD + Connected to + TxD
- Connected to -
RTS + Connected to + CTS
- Connected to -
CTS + Connected to + RTS
- Connected to -
GND Connected to GND
- Connected to -
RxD + Connected to + RxD
- Connected to -
RTS + Connected to + RTS
- Connected to -
CTS + Connected to + CTS
- Connected to -
GND Connected to GND
RJ-45 pinouts
7 SG SG Signal Ground
DB-9 pinouts
Optional 8
Pin
Standard 10- Pin
Pin EIA- 232 EIA-422/ EIA-485 Signal
EIA-422/485
Number Signal 485 (2-Wire Mode)
Signal (4/8 Wire)
Signal (Alt-
4-Wire)
01 RI TXD- (B)
08 CTS CTS+
Recommendations
• Digi recommends shielded cables (15 pF or less capacitance per
foot) for all installations.
• The FCC requires the use of shielded cables to comply with
EMI/RFI emission limits. In addition, cables that run long distances
or through electrically noisy areas are subject to voltage surges that
can cause data errors or equipment damage. EIA-232 specifies a
maximum cable length of 50 feet. If you run cables farther than 50
feet, you increase the risk of surge damage and data loss.
(However, using shielded cable of 10-15 pF capacitance per foot
lessens the risk of data errors somewhat.)
• When routing cables, do not run them parallel to AC wiring or on top
of fluorescent light ballasts.
• Bundling several EIA-232 cables is acceptable.
V.35 pinouts
V.35, male 34-pin connector
Digi One IA
Digi One IA RealPort DB-9 Connector Pinout 63000084-01
RealPort
CSP, Inc. can provide you with reliable fiber assemblies certified to function properly with DigiBoard
equipment.
Fiber is the best solution for transmitting large amounts of data over long distances at high speeds
without interference
or lost data caused by outside factors such as weather, radio frequency signals or other electrical noise.
The ST connector provides these features as well as strong performance and reliability characteristics.
The ST connector
also helps maintain close tolerances when mating connectors in an adapter. The ST connector is easily
recognizable because
of its bayonet style attachment/detachment mechanism.
The ST also offers superior loss characteristics because the ferrules are made of stainless steel or
ceramic and the connector
has a spring-loaded mating system that exerts consistent pressure on the ferrule tip when inserted in an
active device or an adjoining
fiber. These impressive characteristics have allowed the ST connector to become the most widely used
connector in Local
Area Networks (LANs).
CSP fiber optic assemblies are made at the length you specify with or without an optional pulling eye
to meet your individual requirements.
CSP assemblies are made with FDDI grade fiber and tested to meet EIA/FOTP specifications. CSP
complies with the requirements
of the 1990 National Electrical Code (NEC) for Optical Fiber Cables - Article 770.
Specifications:
Fiber Type.......................Glass Graded Index
Core Diameter.................62.5 um
Cladding Diameter...........125 um
Tight Buffer Diameter.......900 um
Numerical Aperture..........>.27
Connector........................ST Stainless
Cable Type......................Duplex (Zipcord)
Orange Jacket
2,3 2,3 2, 3 2, 4 2, 3 1, 8
4,5 4,5 4, 5 3, 5 4, 5 2, 7
6, 8, 15 6, 8, 20 6, 8, 20 6, 7 6, 8, 20
12,13 17, 24 9, 11 9, 11 9, 11
14, 16 10, 12 14, 16
17, 24 13, 14 17, 24
13, 19
10, 22, 23
1 RTS RTS 4
2 DSR DSR 6
Female RJ-45 Male DB-25
3 DCD DCD 8 8-pin
4 RxD RxD 3
5 TxD TxD 2
6 SG SG 7
7 DTR DTR 20
8 CTS CTS 5
From
Signal Signal To DB-25
RJ-45
2 RxD- TxD+ 2
4 RxD+ TxD- 14
5 TxD+ RxD- 16
7 TxD- RxD+ 3
1 RTS CTS 5
3 DCD DTR 20
Female RJ-45 Male DB-25
4 RxD TxD 2 8-pin
5 TxD RxD 3
6 SG SG 7
7 DTR DSR 6
DCD 8
8 CTS RTS 4
1 RTS CTS 8
3 DCD DTR 4
Female RJ-45 Female DB-9
4 RxD TxD 3 8-pin
5 TxD RxD 2
6 SG SG 5
7 DTR DCD 1
DSR 6
8 CTS RTS 7
From
Signal Direction Signal To DB-9
RJ-45
3 DCD DCD 1
4 RxD RxD 2
5 TxD TxD 3
7 DTR DTR 4
6 SG SG 5
2 DSR DSR 6
1 RTS RTS 7
8 CTS CTS 8
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
● This cable utilizes the CTS signal of the modem for hardware flow control (RTS/CTS).
● EIA-232 cables cannot exceed 2500pF.
bl l kh
EIA-232 Boards with RJ-45 (Central Data) Cable Connectors - EtherLite 2, EtherLite 8, EtherLite 16,
EtherLite 160, EtherLite 32, SCSI Terminal Server 1400, SCSI Terminal Server 1800, SCSI Terminal Server
1610, SCSI Terminal Server 1032.
From
Signal Direction Signal To DB-9
RJ-45
4 RxD TxD 3
5 TxD RxD 2
DSR 6
7 DTR
DCD 1
6 SG SG 5
1 RTS CTS 8
8 CTS RTS 7
3 DCD
DTR 4
NOTES:
● This cable utilizes the RTS signal of the PC terminal emulator for hardware flow control (RTS/CTS).
● EIA-232 cables cannot exceed 2500pF.
EIA-232 Boards with RJ-45 (Central Data) Cable Connectors - EtherLite 2, EtherLite 8, EtherLite 16,
EtherLite 160, EtherLite 32, SCSI Terminal Server 1400, SCSI Terminal Server 1800, SCSI Terminal Server
1610, SCSI Terminal Server 1032.
From
Signal Direction Signal To DB-25
RJ-45
3 DCD DCD 8
4 RxD RxD 3
5 TxD TxD 2
7 DTR DTR 20
6 SG SG 7
2 DSR DSR 6
1 RTS RTS 4
8 CTS CTS 5
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
● This cable utilizes the CTS signal of the modem for hardware flow control (RTS/CTS).
● EIA-232 cables cannot exceed 2500pF.
NOTES:
• This cable utilizes the RTS/CTS signals of the modem for hardware flow control.
• A straight-through RJ45 cable is used between Etherlite and modtap adapter.
• EIA-232 cables cannot exceed 2500pF.
NOTES:
• This cable utilizes the RTS/CTS signals of the terminal/printer for hardware flow
control.
• Since null- modem swapping is done within the modtap, a straight-through RJ45
cable is used between EtherLite and modtap adapter.
• EIA-232 cables cannot exceed 2500pF.
NOTES:
• This cable utilizes the RTS/CTS signals of the console/com port for hardware
flow control.
• Since null- modem swapping is done within the modtap, a straight-through RJ45
cable is used between EtherLite and modtap adapter.
• EIA-232 cables cannot exceed 2500pF.
From To RJ-45
Signal Direction Signal
RJ-45 Cisco
3 DCD DTR 2
4 RxD TxD 3
5 TxD RxD 6
7 DTR DSR 7
6 SG SG 5
1 RTS CTS 8
8 CTS RTS 1
From
Signal Direction Signal To DB-25
RJ-45
4 RxD TxD 2
5 TxD RxD 3
DSR 6
7 DTR
DCD 8
6 SG SG 7
1 RTS CTS 5
8 CTS DTR 20
3 DCD
RTS 4
NOTES:
● This cable utilizes the DTR signal of the terminal/printer for hardware flow control (RTS/CTS).
● Okidata printers may use SSD (pin 11) instead of DTR (pin 20) on DB25 side of above diagram. If
this is the case, the printer should be set to SSD+.
● EIA-232 cables cannot exceed 2500pF.
1 DCD DTR 4
2 RTS CTS 8
Female RJ-45 Female DB-9
3 Ground Ground Shell 8-pin
4 TxD RxD 2
5 RxD TxD 3
6 SG SG 5
7 CTS RTS 7
8 DTR DCD 1
Cable Adapter not to scale
DSR 6
* Arrows indicate which direction the signal is flowing
Notes:
All RJ45 cable adapters are 8-pin.
Altpin should be turned on when using this cable adapter so that DTR will drive DCD (standard usage).
If altpin is turned off, the hardware signal on RJ45 pin 1 becomes DSR instead of DCD. This alternative can be used if
DCD is not required, and DSR is needed instead.
This cable adapter utilizes the RTS signal of the serial device for hardware flow control (RTS/CTS).
1 DCD DTR 20
2 RTS CTS 5
Female RJ-45 8-pin Male DB-25
3 Ground Ground Shell
4 TxD RxD 3
5 RxD TxD 2
6 SG SG 7
7 CTS RTS 4
8 DTR DSR 6
1 DCD DTR 20
2 RTS CTS 5
Female RJ-45 8-pin Female DB-25
3 Ground Ground Shell
4 TxD RxD 3
5 RxD TxD 2
6 SG SG 7
7 CTS RTS 4
8 DTR DSR 6
1 DCD DCD 8
2 RTS RTS 4
Female RJ-45 8-pin Male DB-25
3 Ground Ground Shell
4 TxD TxD 2
5 RxD RxD 3
6 SG SG 7
7 CTS CTS 5
8 DTR DTR 20
1 DCD DCD 1
DSR 6
Female RJ-45 Male DB-9
2 RTS RTS 7 8-pin
4 TxD TxD 3
5 RxD RxD 2
6 SG SG 5
7 CTS CTS 8
1 DCD RTS 4
2 RTS CTS 5
Female RJ-45 8-pin Male DB-25
3 Ground Ground Shell
4 TxD RxD 3
5 RxD TxD 2
6 SG SG 7
7 CTS DTR 20
8 DTR DSR 6
From
To Port DB-
Port Signal Signal
9F
RJ45
3 TxD RxD 2
6 RxD TxD 3
4 GND GND 5
DSR 6
2 DTR
DCD 1
8 DSR
DTR 4
7 DCD
1 RTS CTS 8
5 CTS RTS 7
1 CTS CTS 5
2 DSR DSR 6
Female RJ-45 Male DB-25
3 RxD RxD 3 8-pin
4 Ground Ground 7
5 DCD DCD 8
6 TxD TxD 2
7 DTR DTR 20
8 RTS RTS 4
1 CTS RTS 7
2 DSR DTR 4
Female RJ-45 Female DB-9
5 DCD 8-pin
3 RxD TxD 3
4 Ground SG 5
6 TxD RxD 2
8 RTS CTS 8
7 DTR DCD 1
1 CTS RTS 4
2 DSR DTR 20
Female RJ-45 Male DB-25
5 DCD 8-pin
3 RxD TxD 2
4 Ground SG 7
6 TxD RxD 3
8 RTS CTS 5
7 DTR DSR 6
DCD 8
1 CTS RTS 4
2 DSR DTR 20
Female RJ-45 Female DB-25
5 DCD 8-pin
3 RxD TxD 2
4 Ground SG 7
6 TxD RxD 3
8 RTS CTS 5
7 DTR DSR 6
DCD 8
1 CTS CTS 8
4 Ground SG 5
5 DCD DCD 1
6 TxD TxD 3
7 DTR DTR 4
8 RTS RTS 7
Cable Adapter not to scale
From
To Port DB-
Port Signal Signal
25M
RJ45
3 TxD TxD 2
6 RxD RxD 3
4 GND GND 7
2 DTR DTR 20
8 DSR DSR 6
7 DCD DCD 8
1 RTS RTS 4
5 CTS CTS 5
From
To Port DB-
Port Signal Signal
25F/M
RJ45
3 TxD RxD 3
6 RxD TxD 2
4 GND GND 7
DSR 6
2 DTR
DCD 8
8 DSR
DTR 20
7 DCD
1 RTS CTS 5
5 CTS RTS 4
To Port
From
RJ45
Port Signal Signal
Netra
RJ45
Cisco
3 TxD RxD 6
6 RxD TxD 3
4 GND GND 4
2 DTR DSR 7
7 DCD DTR 2
1 RTS CTS 8
5 CTS RTS 1
1 FP_SER_A_DTR 5 FP_SER_A_RXD
2 FP_SER_A_CTS 6 FP_SER_A_RTS
3 FP_SER_A_TXD 7 FP_SER_A_DCD
4 FP_SER_A_GND 8 GND
Below are our recommended cable vendors to make or extend the length of cables
DataCable Technologies
630-226-5600
r.j@datacabletech.com
Contact: RJ Clabots
Black Box
800-231-3222
DB-
Direction Signal
9
1 DCD
2 RxD
3 TxD
4 DTR
5 SG
6 DSR
7 RTS
8 CTS
9 RI
9 DCD
9 DCD
DB-
Direction Signal
9
1 DCD
2 RxD
3 TxD
4 DTR
5 SG
6 DSR
7 RTS
8 CTS
9 RI
DB-
Direction Signal
9
2 RTS+
3 RTS-
4 CTS+
5 CTS-
6 RxD+
7 RxD-
8 TxD+
9 TxD-
Shell GND
DB-
Direction Signal
25
2 TxD+
14 TxD-
3 RxD+
16 RxD-
4 RTS+
19 RTS-
5 CTS+
13 CTS-
Shell GND
* Arrows indicate which direction the signal is flowing
From
RJ-45 To RJ-45
Signal Direction Signal
Digi
Digi
1 DSR DTR 8
5 RxD TxD 4
4 TxD RxD 5
8 DTR DSR 1
6 SG SG 6
2 RTS CTS 7
7 CTS RTS 2
From
DB- Signal Direction Signal To RJ-45
25
8 DCD DTR 2
3 RxD TxD 3
2 TxD RxD 6
20 DTR DSR 7
7 SG SG 5
4 RTS CTS 8
5 CTS RTS 1
1 GND GND 4
NOTES:
From
To RJ-45
DB- Signal Direction Signal
Cisco
25
8 DCD DTR 2
3 RxD TxD 3
2 TxD RxD 6
20 DTR DSR 7
7 SG SG 5
4 RTS CTS 8
5 CTS RTS 1
1 GND GND 4
NOTES:
From
DB- Signal Direction Signal To RJ-45
25
8 DCD DCD 2
3 RxD RxD 5
2 TxD TxD 6
20 DTR DTR 3
7 SG SG 4
6 DSR DSR N/A
4 RTS RTS 8
5 CTS CTS 7
22 RI RI 1
Shell GND GND N/A
From
DB- Signal Direction Signal To RJ-45
25
8 DCD DCD 2
3 RxD RxD 5
2 TxD TxD 6
20 DTR DTR 3
7 SG SG 4
6 DSR DSR N/A
4 RTS RTS 8
5 CTS CTS 7
22 RI RI 1
Shell GND GND N/A
NOTES:
From
Signal Direction Signal To RJ-45
RJ-45
1 DCD DCD 2
5 RxD RxD 5
4 TxD TxD 6
8 DTR DTR 3
6 SG SG 4
2 RTS RTS 8
7 CTS CTS 7
NOTES:
From
Signal Direction Signal To RJ-45
RJ-45
10 DCD DCD 2
6 RxD RxD 5
5 TxD TxD 6
9 DTR DTR 3
7 SG SG 4
2 DSR DSR N/A
3 RTS RTS 8
8 CTS CTS 7
1 RI RI 1
Shell GND GND Shell
NOTES:
● If using this cable with RAS under Windows issue ATS58=1&w to the modem.
● Altpin should be turned off when using this cable.
NOTES:
NOTES:
From
DB- Signal Direction Signal To DB-9
25
8 DCD DCD 1
3 RxD RxD 2
2 TxD TxD 3
20 DTR DTR 4
7 SG SG 5
6 DSR DSR 6
4 RTS RTS 7
5 CTS CTS 8
22 RI RI 9
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
DB- Signal Direction Signal To DB-25
25
8 DCD DCD 8
3 RxD RxD 3
2 TxD TxD 2
20 DTR DTR 20
7 SG SG 7
6 DSR DSR 6
4 RTS RTS 4
5 CTS CTS 5
22 RI RI 22
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
DB- Signal Direction Signal To DB-9
25
8 DCD DCD 1
3 RxD RxD 2
2 TxD TxD 3
20 DTR DTR 4
7 SG SG 5
6 DSR DSR 6
4 RTS RTS 7
5 CTS CTS 8
22 RI RI 9
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
● This cable utilizes the CTS signal of the modem for hardware flow control (RTS/CTS).
From
Signal Direction Signal To DB-9
RJ-45
1 DCD DCD 1
5 RxD RxD 2
4 TxD TxD 3
8 DTR DTR 4
6 SG SG 5
2 RTS RTS 7
7 CTS CTS 8
3 GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
Signal Direction Signal To DB-25
RJ-45
1 DCD DCD 8
5 RxD RxD 3
4 TxD TxD 2
8 DTR DTR 20
6 SG SG 7
2 RTS RTS 4
7 CTS CTS 5
3 GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
Signal Direction Signal To DB-9
RJ-45
10 DCD DCD 1
6 RxD RxD 2
5 TxD TxD 3
9 DTR DTR 4
7 SG SG 5
2 DSR DSR 6
3 RTS RTS 7
8 CTS CTS 8
1 RI RI 9
4 GND GND Shell
* Arrows indicate which direction the signal is flowing
These cables can also be purchased from Digi (See part numbers below).
NOTES:
From
Signal Direction Signal To DB-25
RJ-45
10 DCD DCD 8
6 RxD RxD 3
5 TxD TxD 2
9 DTR DTR 20
7 SG SG 7
2 DSR DSR 6
3 RTS RTS 4
8 CTS CTS 5
1 RI RI 22
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
These cables can also be purchased form Digi (See part numbers below).
NOTES:
NOTES:
NOTES:
From
To
Port
Signal Direction Signal Term/Prn
DB-
DB-9
25
6 DSR
DTR 4
8 DCD
3 RxD TxD 3
2 TxD RxD 2
DSR 6
20 DTR
DCD 1
7 SG SG 5
4 RTS CTS 8
5 CTS RTS 7
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
To
Port
Signal Direction Signal Term/Prn
DB-
DB-25
25
6 DSR
DTR 20
8 DCD
3 RxD TxD 2
2 TxD RxD 3
DSR 6
20 DTR
DCD 8
7 SG SG 7
4 RTS CTS 5
5 CTS RTS 4
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
To
Port
Signal Direction Signal Term/Prn
DB-
DB-9
25
6 DSR
DTR 4
8 DCD
3 RxD TxD 3
2 TxD RxD 2
DSR 6
20 DTR
DCD 1
7 SG SG 5
4 RTS CTS 8
5 CTS RTS 7
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
From
To
Port
Signal Direction Signal Term/Prn
DB-
DB-25
25
6 DSR
DTR 20
8 DCD
3 RxD TxD 2
2 TxD RxD 3
DSR 6
20 DTR
DCD 8
7 SG SG 7
4 RTS CTS 5
5 CTS RTS 4
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
From
Signal Direction Signal To DB-9
RJ-11
4 RxD TxD 3
3 TxD RxD 2
5 SG SG 5
NOTES:
● This cable can only be used with Software Flow Control (Xon/Xoff).
● Some Unix operating systems require carrier to be present. If this is the case, the forcedcd
parameter will need to be turned on for this port at the host.
From
Signal Direction Signal To DB-25
RJ-11
4 RxD TxD 2
3 TxD RxD 3
5 SG SG 7
NOTES:
● This cable can only be used with Software Flow Control (Xon/Xoff).
● Some Unix operating systems require carrier to be present. If this is the case, the forcedcd
parameter will need to be turned on for this port at the host.
From
Signal Direction Signal To DB-9
RJ-11
4 RxD TxD 3
3 TxD RxD 2
5 SG SG 5
1 RTS CTS 8
6 CTS RTS 7
NOTES:
● This cable utilizes the RTS signal of the PC terminal emulator for hardware flow control (RTS/CTS).
● Some Unix operating systems require carrier to be present. If this is the case, the forcedcd
parameter will need to be turned on for this port at the host.
From
Signal Direction Signal To DB-25
RJ-11
1 RTS CTS 5
4 RxD TxD 2
3 TxD RxD 3
5 SG SG 7
6 CTS RTS 4
NOTES:
● This cable utilizes the RTS signal of the PC terminal emulator for hardware flow control (RTS/CTS).
● Some Unix operating systems require carrier to be present. If this is the case, the forcedcd
parameter will need to be turned on for this port at the host.
From
Signal Direction Signal To DB-9
RJ-45
4 TxD RxD 2
5 RxD TxD 3
6 SG SG 5
1 DCD RTS 7
NOTES:
● This cable can only be used with Software Flow Control (Xon/Xoff).
● Some Unix operating systems require carrier to be present. If this is the case, altpin must be
turned on and the DCD-RTS wire added (in some cases it may be possible to wire DCD-RTS as
the fourth wire instead of GND).
From
Signal Direction Signal To DB-25
RJ-45
4 TxD RxD 3
5 RxD TxD 2
6 SG SG 7
1 DCD RTS 4
NOTES:
● This cable can only be used with Software Flow Control (Xon/Xoff).
● Some Unix operating systems require carrier to be present. If this is the case, altpin must be
turned on and the DCD-RTS wire added (in some cases it may be possible to wire DCD-RTS as the
fourth wire instead of GND).
From
Signal Direction Signal To DB-9
RJ-45
3 GND GND Shell
4 TxD RxD 2
5 RxD TxD 3
6 SG SG 5
7 CTS RTS 7
1 DCD DTR 4
2 RTS CTS 8
8 DTR DSR 6
* Arrows indicate which direction the signal is flowing
NOTES:
● Altpin should be turned on when using this cable so that DTR will drive DCD (standard usage).
● If altpin is turned off, the hardware signal on RJ45 pin 1 becomes DSR instead of DCD. This
alternative can be used if DCD is not required, and DSR is needed instead.
● This cable utilizes the RTS signal of the PC terminal emulator for hardware flow control
(RTS/CTS).
From
Signal Direction Signal To DB-25
RJ-45
7 CTS RTS 4
5 RxD TxD 2
4 TxD RxD 3
DSR 6
8 DTR
DCD 8
6 SG SG 7
2 RTS CTS 5
1 DCD DTR 20
3 GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
● Altpin should be turned on when using this cable so that DTR will drive DCD (standard usage).
● If altpin is turned off, the hardware signal on RJ45 pin 1 becomes DSR instead of DCD. This
alternative can be used if DCD is not required, and DSR is needed instead.
From
Signal Direction Signal To DB-9
RJ-45
3 GND GND Shell
4 TxD RxD 2
5 RxD TxD 3
6 SG SG 5
7 CTS RTS 7
1 DSR DTR 4
2 RTS CTS 8
8 DTR DSR 6
* Arrows indicate which direction the signal is flowing
NOTES:
● Altpin should be turned off when using this cable so that pin 1 becomes DSR instead of DCD.
This alternative can be used if DCD is not required, and DSR is needed instead.
● This cable utilizes the RTS signal of the PC terminal emulator for hardware flow control
(RTS/CTS).
From
Signal Direction Signal To DB-9
RJ-45
10 DCD
DTR 4
2 DSR
6 RxD TxD 3
5 TxD RxD 2
DSR 6
9 DTR
DCD 1
7 SG SG 5
3 RTS CTS 8
8 CTS RTS 7
4 GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
Signal Direction Signal To DB-25
RJ-45
10 DCD
DTR 20
2 DSR
6 RxD TxD 2
5 TxD RxD 3
DSR 6
9 DTR
DCD 8
7 SG SG 7
3 RTS CTS 5
8 CTS RTS 4
4 GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
The wiring diagram for an Altpin RJ-45 8-pin to a Cisco Console RJ-45 8-pin adapter cable is shown in Table 1.
From To RJ-45
Signal Direction Signal
RJ-45 Cisco
1 DCD DTR 2
5 RxD TxD 3
4 TxD RxD 6
8 DTR DSR 7
6 SG SG 5
2 RTS CTS 8
7 CTS RTS 1
3 GND GND 4
NOTES:
V.35 Boards with Winchestor cable assemblies (see part numbers for cables below) - Sync
570 (EIA-232 only), Sync 570i (X.21/EIA-530), Sync 570i (EIA-232/V.35), Sync 570i UIB (PCI
boards),Syncport, Sync 2000.
DB-
Direction Signal
25
1 ↔ CGND
2 TxD+
3 RxD+
4 RTS+
5 CTS+
6 DCE Ready +
7 ↔ SG
8 Received Line Signal Indicator +
9 RxClk +
10 Recieved Lne Signal Indicator -
11 TxClk External +
12 TxClk Internal -
13 CTS-
14 TxD-
15 TxClk Internal +
16 RxD-
17 RxClk-
19 RTS-
20 DTE Ready +
22 DCE Ready +
23 DTE Ready -
24 TxClk External -
Shell ↔ GND
NOTES:
X.21/V.11 Boards with DB-15 cable assemblies (see part numbers for cables below) - Sync 570
(EIA-232 only), Sync 570i (EIA-232/V.35), Sync 570i UIB (PCI boards), Syncport, Sync 2000.
V.24 (EIA-232) Boards with DB-25 cable assemblies (see part numbers for cables belo
Sync 570 (EIA-232 only), Sync 570i (EIA-232/V.35), Sync 570i UIB (PCI boards), Syncp
Sync 2000.
• Sync 2000 single port EIA-232 (V.24) DB-25 cable - Part #77000428
• Sync 570i UIB single port EIA-232 DB-25 cable - Part #76000293
• Sync 570/570i 2 port EIA-232 DB-25 - - Part #62500037
• Sync 570/570i 4 port EIA-232 DB-25 - Part #62500036
DB-
Direction Signal
25
1 ↔ CGND
2 TxD+
3 RxD+
4 RTS
5 CTS
6 DSR
7 ↔ GND
8 DCD
TxClk
15
Internal
17 RxClk
20 DTR
TxClk
24
External
Shell ↔ GND
Sync 570 (EIA-232 only), Sync 570i (EIA-232/V.35), Sync 570i UIB (PCI boards), Syncport,
Sync 2000.
DB-
Direction Signal
25
1 ↔ CGND
2 TxD+
3 RxD+
4 RTS+
5 CTS+
6 DCE Ready +
7 ↔ SG
Received Line Signal
8
Indicator +
9 RxClk +
Recieved Lne Signal
10
Indicator -
11 TxClk External +
12 TxClk Internal -
13 CTS-
14 TxD-
15 TxClk Internal +
16 RxD-
17 RxClk-
19 RTS-
20 DTE Ready +
22 DCE Ready +
23 DTE Ready -
24 TxClk External -
Shell ↔ GND
NOTES:
NOTES:
From
DB- Signal Direction Signal To DB-9
25
6 DSR
RTS 7
8 DCD
3 RxD TxD 3
2 TxD RxD 2
20 DTR DSR 6
7 SG SG 5
4 RTS CTS 8
5 CTS DTR 4
Shell GND GND Shell
NOTES:
From
DB- Signal Direction Signal To DB-25
25
6 DSR
RTS 4
8 DCD
3 RxD TxD 2
2 TxD RxD 3
DSR 6
20 DTR
DCD 8
7 SG SG 7
4 RTS CTS 5
5 CTS DTR 20
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
DB- Signal Direction Signal To DB-9
25
6 DSR
RTS 7
8 DCD
3 RxD TxD 3
2 TxD RxD 2
20 DTR DSR 6
7 SG SG 5
4 RTS CTS 8
5 CTS DTR 4
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
From
To
Port
Signal Direction Signal Term/Prn
DB-
DB-25
25
6 DSR
RTS 4
8 DCD
3 RxD TxD 2
2 TxD RxD 3
DSR 6
20 DTR
DCD 8
7 SG SG 7
4 RTS CTS 5
5 CTS DTR 20
Shell GND GND Shell
* Arrows indicate which direction the signal is flowing
From
Signal Direction Signal To DB-9
RJ-11
4 RxD TxD 3
3 TxD RxD 2
5 SG SG 5
NOTES:
● This cable can only be used with Software Flow Control (Xon/Xoff).
● Some Unix operating systems require carrier to be present. If this is the case, the forcedcd
parameter will need to be turned on for this port at the host.
From
Signal Direction Signal To DB-25
RJ-11
4 RxD TxD 2
3 TxD RxD 3
5 SG SG 7
NOTES:
● This cable can only be used with Software Flow Control (Xon/Xoff).
● Some Unix operating systems require carrier to be present. If this is the case, the forcedcd
parameter will need to be turned on for this port at the host.
From
Signal Direction Signal To DB-9
RJ-11
4 RxD TxD 3
3 TxD RxD 2
5 SG SG 5
1 RTS CTS 8
6 CTS RTS 7
NOTES:
● This cable utilizes the RTS signal of the PC terminal emulator for hardware flow control (RTS/CTS).
● Some Unix operating systems require carrier to be present. If this is the case, the forcedcd
parameter will need to be turned on for this port at the host.
From
Signal Direction Signal To DB-25
RJ-11
4 RxD TxD 2
3 TxD RxD 3
5 SG SG 7
1 RTS CTS 5
6 CTS DTR 20
NOTES:
● This cable utilizes the DTR signal of the terminal/printer for hardware flow control (RTS/CTS).
● Okidata printers may use SSD (pin 11) instead of DTR (pin 20) on DB25 side in above diagram. If
this is the case, the printer should be set to SSD+.
● Some Unix operating systems require carrier to be present. If this is the case, the forcedcd
parameter will need to be turned on for this port at the host.
From
Signal Direction Signal To DB-9
RJ-45
4 TxD RxD 2
5 RxD TxD 3
6 SG SG 5
1 DCD RTS 7
NOTES:
● This cable can only be used with Software Flow Control (Xon/Xoff).
● Some Unix operating systems require carrier to be present. If this is the case, altpin must be
turned on and the DCD-RTS wire added (in some cases it may be possible to wire DCD-RTS as
the fourth wire instead of GND).
From
Signal Direction Signal To DB-25
RJ-45
4 TxD RxD 3
5 RxD TxD 2
6 SG SG 7
1 DCD RTS 4
NOTES:
● This cable can only be used with Software Flow Control (Xon/Xoff).
● Some Unix operating systems require carrier to be present. If this is the case, altpin must be
turned on and the DCD-RTS wire added (in some cases it may be possible to wire DCD-RTS as the
fourth wire instead of GND).
From
Signal Direction Signal To DB-9
RJ-45
3 GND GND Shell
4 TxD RxD 2
5 RxD TxD 3
6 SG SG 5
7 CTS DTR 4
1 DCD RTS 7
2 RTS CTS 8
8 DTR DSR 6
* Arrows indicate which direction the signal is flowing
NOTES:
● Altpin should be turned on when using this cable so that DTR will drive DCD (standard usage).
● If altpin is turned off, the hardware signal on RJ45 pin 1 becomes DSR instead of DCD. This
alternative can be used if DCD is not required, and DSR is needed instead.
● This cable utilizes the DTR signal of the terminal/printer for hardware flow control (RTS/CTS).
● EIA-232 cables cannot exceed 2500pF.
From
Signal Direction Signal To DB-25
RJ-45
1 DSR RTS 4
5 RxD TxD 2
4 TxD RxD 3
DSR 6
8 DTR
DCD 8
6 SG SG 7
2 RTS CTS 5
7 CTS DTR 20
3 GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
● Altpin should be turned on when using this cable so that DTR will drive DCD (standard usage).
● If altpin is turned off, the hardware signal on RJ45 pin 1 becomes DSR instead of DCD. This
alternative can be used if DCD is not required, and DSR is needed instead.
● This cable utilizes the DTR signal of the terminal/printer for hardware flow control (RTS/CTS).
● Okidata printers may use SSD (pin 11) instead of DTR (pin 20) on DB25 side of above diagram. If
this is the case, the printer should be set to SSD+.
From
Signal Direction Signal To DB-9
RJ-45
3 GND GND Shell
4 TxD RxD 2
5 RxD TxD 3
6 SG SG 5
7 CTS DTR 4
1 DSR RTS 7
2 RTS CTS 8
8 DTR DSR 6
* Arrows indicate which direction the signal is flowing
NOTES:
● Altpin should be turned off when using this cable so that pin 1 becomes DSR instead of DCD.
This alternative can be used if DCD is not required, and DSR is needed instead.
● This cable utilizes the DTR signal of the terminal/printer for hardware flow control (RTS/CTS).
From
Signal Direction Signal To DB-9
RJ-45
10 DCD
RTS 7
2 DSR
6 RxD TxD 3
5 TxD RxD 2
DSR 6
9 DTR
DCD 1
7 SG SG 5
3 RTS CTS 8
8 CTS DTR 4
4 GND GND Shell
* Arrows indicate which direction the signal is flowing
NOTES:
From
Signal Direction Signal To DB-25
RJ-45
10 DCD
DTR 20
2 DSR
6 RxD TxD 2
5 TxD RxD 3
DSR 6
9 DTR
DCD 8
7 SG SG 7
3 RTS CTS 5
8 CTS RTS 4
4 GND GND Shell
* Arrows indicate which direction the signal is flowing
This cable can also be purchased from Digi (see part number below).
NOTES: