Professional Documents
Culture Documents
Installation Manual: Simrad SR70 Catch Monitoring Receiver
Installation Manual: Simrad SR70 Catch Monitoring Receiver
Installation Manual: Simrad SR70 Catch Monitoring Receiver
Simrad SR70
Catch monitoring receiver
423852/A
August 2020 © Kongsberg Maritime AS
Simrad SR70 Catch Monitoring Receiver
Document information
• Product: Simrad SR70
• Document: Installation Manual
• Document part number: 423852
• Revision: A
• Date of issue: 20 August 2020
Copyright
The information contained in this document remains the sole property of Kongsberg
Maritime AS. No part of this document may be copied or reproduced in any form or by
any means, and the information contained within it is not to be communicated to a third
party, without the prior written consent of Kongsberg Maritime AS.
Warning
The equipment to which this manual applies must only be used for the purpose for
which it was designed. Improper use or maintenance may cause damage to the
equipment and/or injury to personnel. You must be familiar with the contents of the
appropriate manuals before attempting to operate or work on the equipment.
Kongsberg Maritime disclaims any responsibility for damage or injury caused by
improper installation, use or maintenance of the equipment.
Disclaimer
Kongsberg Maritime AS endeavours to ensure that all information in this document is
correct and fairly stated, but does not accept liability for any errors or omissions.
Support information
If you require maintenance or repair, contact your local dealer. You can also contact us
using the following address: simrad.support@simrad.com. If you need information
about our other products, visit https: //www.simrad.com. On this website you will also
find a list of our dealers and distributors.
2 423852/A
Installation Manual
Table of contents
423852/A 3
Simrad SR70 Catch Monitoring Receiver
4 423852/A
Installation Manual
Target audience
The manual is intended for technical personnel; such as skilled shipyard workers,
electricians, qualified engineers and naval architects. It is assumed that you understand
the general principles of maritime electronic equipment. You must also be familiar with
the installation of electronic and mechanical products. You are expected to have basic
mechanical skills and familiarity with handling of sensitive electronic equipment.
Kongsberg Maritime AS will accept no responsibility for any damage or injury to the
system, vessel or personnel caused by equipment that has been incorrectly installed or
maintained, or by drawings, instructions or procedures that have not been prepared by
us. The outline dimensions of the SR70 hydrophone and the relevant installation items
can be found in the Drawing file chapter in this manual.
End user manuals and source drawings (normally in AutoCad format) can be downloaded
from our website.
• https://www.simrad.com
Registered trademarks
Observe the registered trademarks that apply.
Windows® is a registered trademark of Microsoft Corporation in the United States and
other countries.
Simrad®, SIMRAD® and the Simrad® logo are either registered trademarks, or
trademarks of Kongsberg Maritime AS in Norway and other countries.
423852/A 5
Simrad SR70 Catch Monitoring Receiver
Simrad SR70
Related topics
System diagram, page 8
6 423852/A
Installation Manual
Scope of supply
Observe the items provided with the SR70 delivery.
SR70
Item Part number1 In the box
SR70 Catch Monitoring Receiver 396791 SR70 Catch Monitoring Receiver
Power cable
Ethernet cable
USB to RS-232 Serial port adapter cable
Configuration cables
Documentation
1 This is the order number. The number identifies a complete unit and relevant accessories packed in
its shipping container.
Optional items
The items are not included with the SR70 delivery, and must be ordered separately.
Optional items Order number1 Part number2
Computer 419112 428474 The computer contains the operational
software, and offers the user interface that
allows you to control the TV80.
Trawl hydrophone HYD-205254 314-205250 The hydrophone receives the acoustic
communications from the catch sensors
Purse seine HYD-202711 314–202275
and converts these to electrical signals.
hydrophone
Portable HYD-202713 314–203863
hydrophone
1 The number identifies a complete unit and relevant accessories packed in its shipping container.
2 This is the part number on the unit label.
Related topics
System diagram, page 8
423852/A 7
Simrad SR70 Catch Monitoring Receiver
System diagram
The system diagram identifies the main components of a basic SR70 system.
The basic system configuration consists of a SR70, two hydrophones, and a computer
where the Simrad TV80 software runs.
A Display
B Computer + TV80
C SR70 Catch Monitoring Receiver
D Hydrophone (The SR70 Catch Monitoring Receiver allows you to connect four
hydrophones.)
Unless otherwise specified in a contract, the display, the computer, and the hydrophone
are not included in the standard delivery from Kongsberg Maritime.
Related topics
SR70 Receiver Unit, page 6
Scope of supply, page 7
8 423852/A
Installation Manual
Support information
If you need technical support for your Simrad SR70 you must contact your local dealer,
or one of our support departments. A list of all our offices and dealers is provided on our
website. You can also contact our main support office in Norway.
Spain
• Company name: Simrad Spain S.L.U
• Address: Partida Atalayes 20, 03570 Villajoyosa, Spain
• Telephone: +34 966 810 149
• Telefax: +34 966 852 304
• Website: http://www.simrad.es
• E-mail address: simrad.spain@simrad.com
France
• Company name: Simrad France
• Address: 5 rue de Men Meur, 29730 Guilvinec, France
• Telephone: +33 298 582 388
• Telefax: +33 298 582 388
• Website: http://www.simrad.fr
• E-mail address: simrad.france@simrad.com
USA
• Company name: Kongsberg Underwater Technology Inc / Simrad Fisheries
• Address: 19210 33rd Ave W, Suite A, Lynnwood, WA 98036, USA
• Telephone: +1 425 712 1136
• Telefax: +1 425 712 1193
• Website: https://www.simrad.com
• E-mail address: fish.usa.support@simrad.com
423852/A 9
Simrad SR70 Catch Monitoring Receiver
Canada
• Company name: Kongsberg Mesotech Ltd.
• Address: 1598 Kebet Way, Port Coquitlam, BC, V3C 5M5, Canada
• Telephone: +1 604 464 8144
• Telefax: +1 604 941 5423
• Website: https://www.simrad.com
• E-mail address: simrad.canada@simrad.com
Malaysia
• Company name: Kongsberg Maritime Malaysia Sdn. Bhd
• Address: Unit 27-5 Signature Offices, The Boulevard, Mid Val-
ley City, Lingkaran Syed Putra, 59200 Kuala Lumpur, Malaysia
• Telephone: +65 6411 7488
• Telefax: +60 3 2201 3359
• Website: https://www.simrad.com
• E-mail address: simrad.asia@simrad.com
Korea
• Company name: Kongsberg Maritime Korea Ltd
• Address: #1101 Harbor Tower, 113-1, Nampodong 6-Ga, Jung-Gu, Busan 600-
046, Korea
• Telephone: +82 51 242 9933
• Telefax: +82 51 242 9934
• Website: https://www.simrad.com
• E-mail address: simrad.korea@simrad.com
China
• Company name: Kongsberg Maritime China Ltd
• Address: 555 Chuanqiao Road, China (Shanghai) Pilot Free Trade Zone, 201206, China
• Telephone: +86 21 3127 9888
• Telefax: +86 21 3127 9555
• Website: https://www.simrad.com
• E-mail address: simrad.china@simrad.com
10 423852/A
Installation Manual
Prerequisites
A suitable location for the SR70 must be defined prior to installation. The unit can in
principle be mounted anywhere on board the ship, provided that the location is dry and
ventilated. The physical length of the cables limits the distance between the receiver
and the hydrophone.
You must be equipped with a standard set of tools. This tool set must comprise the
normal tools for electronic and electromechanical tasks.
Context
If you mount the SR70 on a bulkhead, position the unit so that all the connectors are
facing down.
Ensure maximum physical distance between the receiver unit and the power supply
unit. This is important to reduce noise.
Procedure
1 Observe the installation requirements.
a The position must be chosen to fit the available cable lengths between the
receiver unit and the other units it connects to.
b Make sure that enough space is made available for maintenance purposes.
c Make sure that adequate ventilation is available to avoid overheating.
d Make sure that the installation method allows for the physical vibration,
movements and forces normally experienced on a vessel.
2 Place the unit in the selected location.
3 Secure the unit using four bolts or screws.
4 Connect the cables.
Note
When you connect the cables, make sure that they are all properly secured, and able
to withstand the vibration and movements of the vessel.
423852/A 11
Simrad SR70 Catch Monitoring Receiver
Cable plan
The cables are used to connect the SR70 to the computer and to the hydrophone or
hydrophones.
A Display
B Computer + TV80
C SR70 Catch Monitoring Receiver
D Hydrophones
Cables identified with an asterisk (*) are system or commercial cables. These cables are
provided with the SR70 delivery or the relevant item.
Related topics
List of SR70 cables, page 13
12 423852/A
Installation Manual
Computer cables
Cable Type From/To Minimum requirements
C03 Video cable From computer to display
This is a commercial cable. The display cable is often physically attached to the display,
and terminated in the “computer end” with a male connector.
C06 Ethernet cable From computer to Receiver Unit. CAT-6
C09 Serial cable From computer to Receiver Unit.
Note
Cable numbers not shown are not relevant for the purpose of this manual.
Related topics
Cable plan, page 12
423852/A 13
Simrad SR70 Catch Monitoring Receiver
Setting up summary
Before a new SR70 Catch Monitoring Receiver can be put to use, it must be set up
for operation.
Prerequisites
The Receiver Unit must be connected to the computer using an Ethernet line.
Context
This information describes several sequential tasks. For the detailed procedures, see the
TV80 Reference Manual or Online help.
Procedure
1 Turn on the computer.
2 Open the Network Connections dialog box.
3 Define the IP address on the Ethernet adapter.
• IP Address: 192.168.1.30
• Subnet mask: 255.255.255.0
4 Install the TV80 software.
5 On the Software License page, install the software license(s).
6 Set up the relevant Receiver Unit(s).
a On the Setup menu, select Installation.
b Select Add LAN Port to open the Select Input (LAN) dialog box.
c Select the SR70 Catch Monitoring Receiver.
14 423852/A
Installation Manual
The graph in the Spectrum dialog box provides you with information about
the background noise and the signal strength in the selected frequency band.
With the channel identifiers you can easily see in which channels you have
signals and noise.
8 Select the gear you wish to use.
The Select Gear page is located at the left of the Installation
dialog box.
9 Select one or more catch monitoring sensors, and place them
on the chosen gear.
To open the Add New Sensor dialog box, select Add New
Sensor at the bottom of the Sensor list page in the Installation
dialog box.
10 Define the relevant sensor view according to your needs and
sensors configuration.
423852/A 15
Simrad SR70 Catch Monitoring Receiver
Technical specifications
These technical specifications summarize the main functional and operational
characteristics of the SR70 Catch Monitoring Receiver.
Note
At Kongsberg Maritime, we are continuously working to improve the quality and
performance of our products. The technical specifications may be changed without
prior notice.
Power requirements
• Voltage requirement: 110 – 230 VAC / +24 DC
Maximum voltage deviation: 15%
Environmental requirements
• Operating temperature: 0 to +50 °C
• Storage temperature: -40 to 70 °C
• Relative humidity: 5 to 95% relative, non-condensing
• Ingress protection (IP) rating: IP52
16 423852/A
Installation Manual
423852/A 17
Simrad SR70 Catch Monitoring Receiver
18 423852/A
Simrad SR70 Catch Monitoring Receiver
19 423852/A
©2020 Kongsberg Maritime