Download as doc, pdf, or txt
Download as doc, pdf, or txt
You are on page 1of 1

Routine activities to Reduce Data Sleeping Cell Problem

1. After any EDAP related activity (Deletion/Addition/Modification), Site reset & after that BCSU Switchover will be given by GNSC. 2. GNSC will toggle the GENA for cells having 7789 Alarm observed every day at 4 AM and 10 PM 3. Weekly BCSU switch over will be done by circle team 4. GNSC will monitor the BVCI, GENA & status for All the cells at 6 AM, take MML output and based on that they will take the corrective action (GENA toggling, NSEI RESET etc) and provide the list to circle Team. 5. After MPLS Fluctuation GNSC will verify the BVCI status, monitor NSEI Toggling alarm and will take the corrective action if required. 6. After SGSN upgrade, GNSC will verify BVCI status for all the Cells. PaCo team should inform GNSC after the completion of activity. 6. Circle NPO will analyze the Cells having DBBH payload ZERO & provide analyzed data to GNSC. GNSC will carryout Analysis & if any corrective action is to be taken, circle BSS will take the action. 7. PCU Loading should be less than 90% (Circle NPO will ensure) 8. Remote BSC Gb BW utilization should be less than 70% . (Circle NPO will ensure). If any corrective action is to be taken, circle BSS & Transmission team will take the corrective action.

Process Flow Diagram for Routine Activities Routine Activities to Reduce Sleeping Cell Problem

Start

Daily Monitoring of 7789 alarm

GNSC running script to check7789 alarm every 2 Hrs

Toggling of GENA for Cells having 7789 alarm observed

Daily at 4 AM & 10 PM

GNSC

Any EDAP related activity ?


Yes

No

NSEI Rebalancing ?
Yes

No

SGSN Upgrade ?
Yes

No

Monitor BVCI, GENA, EGENA status for all Cells at 6 AM, take MML output

Any corrective action required ?

Yes

Site Reset

BCSU switchover to be given

Check BVCI status for all Cells

No

Take corrective action (e.g. GENA toggling, NSEI reset etc ) & share with circle team Close

Close

Check BVCI status& NSEI Toggling alarm

Yes

Any MPLS fluctuation ?

No

Take corrective action if required

GNSC to analyze & revert with the action to be taken by circle

Start

Circle NPO to monitor RF/GPRS performance

NPO to analyze the Cells (EDGE & GPRS) having DBBH payload zero & provide analyzed data to GNSC

BSS to take action

Start

NPO, BSS

Circle to do Weekly BCSU switchover Close

NPO to maintain PCU loading < 90 % NPO to ensure Remote BSC Gb BW utilization < 70 % BSS/Transmission to take action if utilization exceeds 70 %

NPO to maintain PCU loading < 90 %

You might also like