Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

DRESSER-RAND

Reciprocating Compressor Installation Record


Field Services Start-up records
End user : DR contract n° :
Recip type : DR Project n° :
Serial number : Services dates from \: to :
Original start up date : Hrs nb: DR field rep. :
Customer machine Tag#: DR office support :

Unloaded test
Date :
Time 1000 1030 1100 1200 1300 1400 1500
OIL CIRCUIT CHECK Unit 1 min 30 min 1 hrs 2 hrs 3 hrs 4 hrs 5 hrs
Lube oil pump pressure Kg/cm2g
Lube oil pressure Kg/cm2g
P oil filter Kg/cm2g
Oil temperature crankcase °C
Oil t°F inlet bearing °C
T°C inlet water cooler °C
T°C outlet water cooler °C
Bearing : Main Bearings
Time 1000 1030 1100 1200 1300 1400 1500
BEARING CONTROL Unit 1 min 30 min 1 hrs 2 hrs 3 hrs 4 hrs 5 hrs
Bearing # 10-TE-560A °C
Bearing # 10-TE-561A °C
Bearing # 10-TE-562A °C
Bearing # 10-TE-563A °C
Bearing # 10-TE-564A °C
Bearing # 10-TE-565A °C
°C

Cylinder: 4 Cylinder
Time 1000 1030 1100 1200 1300 1400 1500
CYLINDER CONTROL Unit 1 min 30 min 1 hrs 2 hrs 3 hrs 4 hrs 5 hrs
Cylinder # 1
T°C piston rod °C
T°C oil packing °C
T°C auxiliary packing °C
T°C gas packing °C
T°C water inlet °C
T°C water outlet °C
Cylinder # 2
T°C piston rod °C
T°C oil packing °C
T°C auxiliary packing °C
T°C gas packing °C
T°C water inlet °C
T°C water outlet °C
Cylinder # 3
T°C piston rod °C
T°C oil packing °C
T°C auxiliary packing °C
T°C gas packing °C
T°C water inlet °C
T°C water outlet °C

DR service representative : Customer approval:


Name: Name:
Sign Sign
Page : 01
DRESSER-RAND Maintenance check sheets for Recip compressor

Field Services Start-up records


End user : DR contract n° :
Recip type : DR Project n° :
Serial number : Services dates from \: to :
Original start up date : Hrs nb: DR field rep. :
Customer machine Tag#: DR office support :

Time 1000 1030 1100 1200 1300 1400 1500


CYLINDER CONTROL Unit 1 min 30 min 1 hrs 2 hrs 3 hrs 4 hrs 5 hrs
Cylinder # 4
T°C piston rod °C
T°C oil packing °C
T°C auxiliary packing °C
T°C gas packing °C
T°C water inlet °C
T°C water outlet °C
Cylinder # 5
T°F piston rod °F
T°F oil packing °F
T°F auxiliary packing °F
T°F gas packing °F
T°F water inlet °F
T°F water outlet °F
Cylinder # 6
T°F piston rod °F
T°F oil packing °F
T°F auxiliary packing °F
T°F gas packing °F
T°F water inlet °F
T°F water outlet °F

LUBRICATOR OIL FLOW Adjustement : This is a Lubricated Compressor


Unit Cylinder 1 Cylinder 2 Cylinder 3 Cylinder 4 Cylinder 5 Cylinder 6
Suction of cylinder Drop/min
Top of cylinder (1) Drop/min
Top of cylinder (2) Drop/min
Bottom of cylinder Drop/min
Gas packing (1) Drop/min
Gas packing (2) Drop/min
Other: Drop/min

Oil flushing Yes No Filtration: microns Duration: days Oil temperature: °C

Remark :

DR service representative : Customer approval:


Name: Name:
Sign Sign

Page : 02