Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

FOR APPROVAL

UP UP

DN
GARDEN/YARD GARDEN/YARD

ACU

COMMON LAUNDRY AREA

LA

O
EM
AF R
O

KITCHEN AREA
25mmT&B 50mm
DINING/KITCHEN AREA T&B

LIVING AREA

COMMON
WIC T&B WASH AREA
50mm
25mm

KITCHEN AREA
FLEXIBLE/OPEN
SPACE

DN
PARKN
IG
COMMON
OR AF L
EM

A
GARDEN/YARD GARDEN/YARD T&B
BEDROOM 1 ACTIVITY AREA

LA

O
EM
AF OR

MUSIC ROOM
BEDROOM 2

ACU

UCA
MASTER BEDROOM

ACU
BALCONY GARDEN
UP
MAIN ENTRY

O
R AF
EM L
O

UP
OUTDOOR SEATING
UP

PEDESTRIAN GATE PARKING GATE

PEDESTRIAN PATH WAY

PART OF THE ROAD

GROUND FLOORPLAN
GROUND FLOOR SECOND FLOOR THIRD FLOOR
1 PROPOSED FLOOR PLAN 2 PROPOSED FLOOR PLAN 3 PROPOSED FLOOR PLAN

REVISION HISTORY
- RMM
- FURNITURE LAYOUT
RMM
04/04/2022
AS SHOWN ID 1.0
INTERIOR RENOVATION FOR CONSTRUCTION
FOR APPROVAL

UP
UP

GARDEN/YARD DN
GARDEN/YARD

ACU

GARDEN/YARD

ACU

UCA

UCA
ACU
BALCONY

PEDESTRIAN GATE PARKING GATE

PEDESTRIAN PATH WAY

PART OF THE ROAD

GROUNDFLOORPLAN
GROUND FLOOR SECOND FLOOR THIRD FLOOR
1 REFLECTED CEILING PLAN 2 REFLECTED CEILING PLAN 3 REFLECTED CEILING PLAN

REVISION HISTORY
- RMM
- REFLECTED CEILING PLAN
RMM
04/04/2022
AS SHOWN ID 1.1
INTERIOR RENOVATION FOR CONSTRUCTION
FOR APPROVAL

UP

UP

GARDEN/YARD

DN
GARDEN/YARD

UP

ACU

GARDEN/YARD

BALCONY

PEDESTRIAN GATE PARKING GATE

PEDESTRIAN PATH WAY

PART OF THE ROAD

GROUNDFLOORPLAN
GROUND FLOOR SECOND FLOOR THIRD FLOOR
1 LIGHTING LAYOUT PLAN 2 LIGHTING LAYOUT PLAN 3 LIGHTING LAYOUT PLAN

REVISION HISTORY
- RMM
- LIGHTING LAYOUT PLAN
RMM
04/04/2022
AS SHOWN ID 1.2
INTERIOR RENOVATION FOR CONSTRUCTION
FOR APPROVAL

CO

RJ11
UP

RJ45

GARDEN/YARD UP

DN
UP
GARDEN/YARD

GFCI
UP
WP
WP
WP WP WP WP

COMMON

O
E
FL A
MOR

ACU
CO CO CO
CO AC REF CO WP
25mm T&B 50mm

LAUNDRY AREA
KITCHEN AREA WP
CO CO DINING/KITCHEN AREA T&B
CO
CO WP

WP
LIVING AREA

COMMON
KITCHEN AREA T&B WASH AREA
WIC WP
FLEXIBLE/OPEN 25mm
50mm

SPACE
CO

CO CO
REF WP CO

PARKN
IG DN
CO CO
R A
O FL
EM

A
CO
CO
GARDEN/YARD COMMON
GARDEN/YARD T&B
BEDROOM 1 ACTIVITY AREA

O
E
FL A
MOR

CO
CO
WP
MUSIC ROOM
CO
CO
BEDROOM 2

ACU

UCA
MASTER BEDROOM CO

CO

CO

ACU
BALCONY
WP WP
GARDEN
UP
CO
AC CO CO
CO MAIN ENTRY

R A
O FL
EM
O

UP
OUTDOOR SEATING
UP

PEDESTRIAN GATE PARKING GATE

PEDESTRIAN PATH WAY

PART OF THE ROAD


SECONDFLOORPLAN
GROUNDFLOORPLAN
GROUND FLOOR SECOND FLOOR THIRD FLOOR
1 POWER AND AUXILIARY 2 POWER AND AUXILIARY 3 POWER AND AUXILIARY

REVISION HISTORY
- RMM
- POWER AND AUXILIARY PLAN
RMM
04/04/2022
AS SHOWN ID 1.3
INTERIOR RENOVATION FOR CONSTRUCTION

You might also like